BLD2021-0579_Structural_Calculations_4.22.2021_3.21.37_PM_2159737Required Setbacks from Ridge: NSA Maximum Mount Spacing: 48^ Roof Type: SSM Roof Slope: 5o Array Tilt : Flush Array Azimuth(s): 90-,180- Roof Area: 3532ft2 Array Area 378ft2 Array to Roof Coverage 11% * * *Roof Attachments/ Fastners: see pg. G5 Equip, BOM* * * Module and Rail Selection Guide Panasonic HIT 325 41.5 x 62.6 Clamp Zone "A" 0-9.8" Clamp Zone "B" 9.1-17.7" Mods per Row Rail typel+ rail type2 (7)Portrait, (2)rows (2)14', (2)14' (4)Portrait, (1)row (2)17', (3)Portrait, (1)row (2)14', "All "Q" _ I A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. L C a-+ Y EQ O p > N Se O O 00 0� O _V •.//�\ YV) (D 0 L Q U 0 Q X Nt U U �: Qooq � N `-' 00 O E _ i N -0 '= 00 W Q0 U u 0 0 a REVISIONS Rev. #: Date: 1 I Apr 07, 2021 Designed by: Brian G Project Manager: Will MacArthur (206)307-1741 Current Date:ADr 07. 2021 A2 Roof Layout ■ = A & R Scope `„I' = Existing or A&RSOLAR Others Scope 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 Net Meter, 200A Service r— — — — — — — — — — — — I I Disconnect I (Existing) O Main Service Panel (1ph 240V Service) M String 1 +/- — � D Main Breaker: 200A g \ 11 modules + 0 0 Bus Rating:200A V- - - - - - - N - - - - - - - - - - - - - - . String 2 I I Solar OCPD: 2p4OA 10 modules + T I — — — — 5 U Ac AAB Co -Located with Net Meter Customer Owned (less than 10' away) Production Meter = 0 Equipment Schedule Ref. Category Equipment CITY 1 Modules Panasonic HIT 325 21 2 Optimizers P400 SolarEdge Optimizer 21 3 Jbox Jbox 2 4 Inverters Solar Edge SE6000H 1 5 Disconnect 60A 600V 2 Pole l Heavy Duty, No Fuse, Lockable 1 6 MeterBase MeterBase-125A 4 Jaw w/ 3.5" AWCAP 1 Meter Landis Gyr EA110000-OP29 240V 1 Monitoring SolarEdge Integrated (inverter) Monitoring 1 0 Conductor Schedule Summary A (2)#10 CU, (1)#10 EGC, PV Wire 60OV, AIR B (4)#10 CU, (1)#10 EGC, THWN-2, 0.75"EMT(min) C (2)#8 CU, (1)#10 N, (1)#10 EGC, THWN-2, 0.75"EMT(min) D (2)#8 CU, (1)#10 N, (1)#10 EGC, THWN-2, 0.75"EMT(min) nverter Specs Watts LW-1 Output � AC Voltage # of Inverters OCPD Solar Edge SE6000H 6000 25 240 1 40 ****N/A**** 0 0 0 0 0 ****N/A**** 0 0 0 0 0 Module Specs Watts w Imp Vmp Voc Isc Panasonic HIT 325 1 325 5.5 1 59.2 70.9 5.94 Temp. Adjusted 1 0 0 55.8 74.8 1 0 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. i }0 E Q O 0 3: N = O O W � � O (A U �TT � X U aC)00 0 _ Ln -- E •L 00 Lu c6 c� U a+ U •O L IL REVISIONS Rev. #: Date: 1 Apr 07, 2021 General Notes: Utility: SnoPUD 1. EGC Where exposed to physical damage will be #6AWG Bare CU 2. If installing conduit on the roof, maintain greater than 7/8" above the surface 3. NEC 690.12: Rapid Shutdown initiated by loss of Grid or AC Disconnect Designed by: Brian G Project Manager: Will MacArthur (206) 307-1741 Distance (ft) Current @125% Operating Voltage Voltage Drop Volt. Drop (total) 50 18.75A 380V 0.31% 0.94% Current Date:Apr 07, 2021 50 18.75A 380V 0.31% El Single Line 10 31.25A 240V 0.16% 10 31.25A 240V 0.16% PV Electrical Calculations Inverter Specs Watts Output AC - Voltage # of Inverters OCPD Total AC Comb. EGC AC (W) out.(A) OCPD Solar Edge SE6000H 6000 25.00 240 1 40 25.0 35 410 P Ampe ****N/A**** 0 0.00 0 0 0 ****N/A**** 0 0.00 0 0 0 Module Specs Watts I� Vmp Voc Is Temp. Coef V(oc) EGC DC Volt at Panasonic HIT 325 325 5.50 59.2 70.9 5.94 -0.17 #10 Max Vc Max Temp. Adjusted 55.8 74.8 Optimizer? P400 SolarEdge Optimizer Max current output: 15A, Max Voltage: 480V Equipment Solar Edge SE6000H ****N/A**** ****N/A**** Mppt Input 1 2 1 3 1 1 2 J 3 1 1 2 1 3 Module Panasonic HIT 325 ****SELECT**** ****SELECT**** # Modules per String 11 10 0 0 0 0 0 0 0 # Strings 1 1 0 0 0 0 0 0 0 # of Mods per group 11 10 0 0 0 0 0 0 0 # of Mods/inverter 21 0 0 # of Inverters 1 0 0 Total # of Modules 21 Ref. Conductor Description Distatnce AL CU A (String) to Jbox 50 CU B Jbox to Inverter 50 Cu C Inverter to Disconnect 10 CU D Disco. to Interconnect 10 CU E F G H I nverter 1Ippt Input -age (Imp) age (Vmp) iltage(DC) kmps (DC) Array Specs (Adiusted for Temperature) Solar Edge SE6000H ****N/A**** ****N/A**** 1 2 3 1 2 3 1 2 3 9.43 8.57 0.00 0.00 0.00 0.00 0.00 0.00 0.00 380.0 380.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 480.0 480.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 15.00 15.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Max Array Power(STC): 6.825 kW DC Max Continuous AC Power: 6kW AC Interconnection Calcs Main Breaker 200 Bus Bar 200 Max PV OCD AI lowed 40 PV OCPD Device Used 40 Tap or Breaker? Breaker Wire jaL (QTY) Phase Neutral Neutral EGC (AWG) Wire Type Conduit Min. Conduit 90°C Rating Temp Correct. Fill Derate Derated Ampacity Conductors AWG (QTY) Tvpe #10 2 N/A N/A #10 PV Wire 600V AIR N/A 40 1 100% 40.00 #10 4 N/A N/A #10 THWN-2 EMT 0.75" 40 1 80% 32.00 #8 2 #10 1 #10 THWN-2 EMT 0.75" 55 1 100% 55.00 #8 2 #10 1 #10 THWN-2 EMT 0.751' 55 1 100% 55.00 A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR ND ITS RECEPTOR. POSSESSION DOES NOT )NFER ANY RIGHT IN OR LICENSE TO USE IT -IR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS J RAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. L. ID U E Q Site Conditions Low Temp (°F) 19 High 0.4%Temp (°F) 91 ASHRAE Site: Seattle High 2%Temp (°F) 84 O N O 00 0000 � M O �Q aIt U� a) Q0 Q 00 N 00 O E_ 0 W 50 31.3 240 0.16% REVISIONS Rev. #: Date: 1 Apr 07, 2021 Designed by: Brian G Total Voltage Drop: 0.94% Project Manager: Will MacArthur (206)307-1741 Current Date:Apr 07, 2021 E2 Electrical Calculations O N O 00 0000 � M O �Q aIt U� a) Q0 Q 00 N 00 O E_ 0 W 50 31.3 240 0.16% REVISIONS Rev. #: Date: 1 Apr 07, 2021 Designed by: Brian G Total Voltage Drop: 0.94% Project Manager: Will MacArthur (206)307-1741 Current Date:Apr 07, 2021 E2 Electrical Calculations Typical Placards A) NEC 2020 690.13 & 691.15 B) NEC 2020 705.12 (13)(3)(2) C) Utility Requirement D) Utility Requirement (Commercial Only) D) A&R Solar Requirement (Residential Customer -Owned) E) A&R Solar Requirement * if combiner used F) NEC 2020 690.13 (B) I) NEC 2020 690.31 (D)(2) K) NEC 2020 690.13 (B) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SOLAR ELECTRIC PV PANELS SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY L) NEC 2020 690.56 (C) *Used with Micro Inverters or DC Optimizers O) A&R Solar Requirement * if multiple inverters IAWARNING DUAL POWER SOURCE] SECOND SOURCE IS PHOTOVOLTAIC SYSTEM P) NEC 2020 705.12(C) & 690.59 R) AHJ Requirement * if combiner used S) NEC 2020 230.85(1) T) NEC 2020 230.85(3) Custom Placards &*1.PAi A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 'LACARD SPECS QTY G) NEC 690.54 THIS DRAWING CONSTITUTES THE Letter Height: 1/8" MAX AC • • I inverter CONFIDENTIAL INFORMATION OFA&RSOLAR , border Maintain 1/4' 1 AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OPERATING VOLTAGE: 1 V AC Red / White Breaker OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT H) NEC 690.53 THE WRITTEN CONSENT OF A&R SOLAR. L MAX DC VOLTAGE:480.0 Letter Height: 1/8" � CURRENT:MAX DC CIRCUIT 1 A DC Maintain 1/4" border 1 Solar Edge SE6000H = CURRENTMAX CIRCUIT • Red / White DC TO DC CONVERTER1 A DC Y G NEC 690.54 AC OUTPUT CURRENT: 25 A AC Letter Height: 1/8" (1) for each UMAX Maintain 1/4" border 1 Disconnect or upstream O N Red / White loadcenters. _ W U o � 00 � 00•- 0 - >, a U) Q� TT U _ U O � Q O N 00 O U) N _0 •_ 00 Lu L � M U U •o a REVISIONS Rev. #: Date: 1 Apr 07, 2021 Designed by: Brian G Project Manager: Will MacArthur (206)307-1741 Current Date:Apr 07, 2021 G4 Placards J) NEC 2020 690.56 (C)(2) Category Equipment QTY Notes Solar Equipment Modules Panasonic HIT 325 21 Optimizers P400 SolarEdge Optimizer 21 Inverters Solar Edge SE6000H 1 Monitoring SolarEdge Integrated (inverter) Monitoring 1 Electrical Equipment Jbox Jbox 2 Disconnect 60A 600V 2 Pole I Heavy Duty, No Fuse, Lockable 1 MeterBase Mete r8ase-125A 4 Jaw w/ 3.5" AWCAP 1 Meter Landis Gyr EA110000-OP29 240V 1 Solar Racking IronRidge Racking BOM Description QTY XR10 Black,17' 2 XR10 Black,14' 10 Kit, XR10 Bonded Splice BOSS 4 Universal Module Clamp, Black 50 Stopper Sleeve 40mm 16 Grounding Lug, Low Profile 4 Square -Bolt Bonding Attachment Hardware 47 1/4 x 3/4 Microinverter Bonding Hardware, T-Bolt 21 End Caps, 10 sets(package) XR10 1 S-5! Clamp, Mill (Spacing: 48") 47 L-Feet, Black 47 System Weights Racking Weight(Ibs) 168 Total Weight(lbs) 1025 Weight/Attachment(lbs) 22 DeadLoad(PSF) 2.71 A&RSOLAR 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR. POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATION DISCLOSED HEREIN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HEREIN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. i C Y E Q O p > N O O00 � 'N 0 O i Q �(_5 a� C) X It U U Q O O N 00 O Ln E N N � 00 W L � U U �O i a REVISIONS Rev. #: Date: 1 1 Apr 07, 2021 Designed by: Brian G Project Manager: Will MacArthur (206) 307-1741 Current Date:ADr 07, 2021 G5 Equipment BOM