BLD2021-0458_Manufacturer_Specifications_and_Installation_Instructions_3.31.2021_1.43.30_PM_2120865A*& iew s7itqd&rd® HEATING & AIR CONDITIONING Submittal Split System Cooling 4A7A3049A1000N Note: "Graphics in this document are for representation only. Actual model may differ in appearance. " TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. March 2017 4A7A3049A-SUB-1 B-EN 40H ingerso►►Rand., S H EATING & Al R CONDITIONING SERVICE ELECTRICAL AN COMPONENT C L E PER PREVAILING TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524 (5 FEET) ABOVE UNIT. UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 305 (12") FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED. ELECTRICAL SERVICE PANEL 22,2 (7/8) DIA. HOLE LOW VOLTAGE 28.6 (1-1/8) DIA. K.O. WITI 22.2 (7/8) DIA. HOLE IN CONTR01 BOX BOTTOM FOR ELECTRICAI POWER SUPPL' K 25 (1) A i r FI F LIQUID LINE SERVICE VALVE, E' I.D. FEMALE BRAZE CONNECTION WITH 1/4" SAE FLARE PRESSURE TAP FITTINGS. `K.O. FOR ALTERNATE ELECTRICAL ROUTING GAS LINE 1/4 TURN BALL SERVICE VALVE, 'D" I.D. FEMALE BRAZED CONNECTION WITH 1/4' SAE FLARE PRESSURE TAP FITTING. Model Base A B C D E F G H J K 4A7A3049A 4 741 946 870 7/8 3/8 143 83 206 70 508 (29-1/8) (37-1/4) (34-1/4) (5-5/8) (3-1-4) (8-1/8) (2-3/4) (20) Sound Power Level A -Weighted MODEL Sound Power Full Octave Sound Power(dB) Level [dB(A)] 63 Hz* 125 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 8000 Hz Hz Hz 4A7A3049A1 74 72.5 72.3 69.2 67.5 1 72.3 60.2 55.2 54.2 Note: Rated in accordance with AHRI *For Reference Only Standard 270-2008 4A7A3049A-SUB-1 B-E N S H EATING & Al R CONDITIONING Product Specifications OUTDOOR UNIT (a) (b) 4A7A3049A1000A POWER CONNS. — V/PH/HZ (c) 208/230/1/60 MIN. BRCH. CIR. AMPACITY 24 BR. CIR. PROT. RTG. — MAX. (AMPS) 40 COMPRESSOR DURATION'"'- SCROLL NO. USED — NO. STAGES 1-1 VOLTS/PH/HZ 208/230/1/60 R.L. AMPS (d)— L.R. AMPS 18.5 — 124 FACTORY INSTALLED START COMPONENTS (e) NO (Uses BAYKSKT263) INSULATION/SOUND BLANKET NO COMPRESSOR HEAT NO OUTDOOR FAN PROPELLER DIA. (IN.) — NO. USED 27.5 — 1 TYPE DRIVE — NO. SPEEDS DIRECT— 1 CFM @ 0.0 IN. W.G. M 3970 NO. MOTORS — HP 1-1/5 MOTOR SPEED R.P.M. 835 VOLTS/PH/HZ 200/230/1/60 F.L. AMPS 1.05 OUTDOOR COIL — TYPE SPINE FIN"" ROWS—F.P.I. 1-24 FACE AREA (SQ. FT.) 19.07 TUBE SIZE (IN.) 3/8 REFRIGERANT LBS. — R-410A (O.D. UNIT) (g) 6 LBS., 9 OZ FACTORY SUPPLIED YES LINE SIZE — IN. O.D. GAS (h) 7/8 LINE SIZE — IN. O.D. LIQ. 3/8 CHARGING SPECIFICATIONS SUBCOOLING 10°F DIMENSIONS H X W X D CRATED (IN.) 34.4 x 35.1 x 38.7 WEIGHT SHIPPING (LBS.) 212 NET (LBS.) 189 (a) Certified in accordance with the Air -Source Unitary Air -conditioner Equipment certification program, which is based on AHRI standard 210/240. (b) Rated in accordance with AHRI standard 270. W Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers or fuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. W No means no start components. Yes means quick start kit components. Optional kit shown. (f) Standard Air — Dry Coil — Outdoor (g) This value approximate. For more precise value see unit nameplate. (h) Max. linear length 60 ft.; Max. lift — Suction 60 ft.; Max. lift — Liquid 60 ft. For greater length consult refrigerant piping software Pub. No. 32-3312-0* (* denotes latest revision). 4A7A3049A-SUB-1 B-EN ,��cicay �S�il0 HEATING & AIR CONDITIONING Mechanical Specification Options General The Outdoor Units are fully charged from the factory for up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 1995. Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather -resistant powder paint finish on all louvered panels and the fan top panel. The corner panels are prepainted. All panels are subjected to our 1,000 hour salt spray test . The base is made of a CMBP-G30 weatherproof material to resist corrosion. Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and high pressure switch. High and low pressure controls are inherent to the compressor. A factory supplied liquid line drier is standard. Some models may require field installation, Compressor The compressor features internal over temperature, pressure protection and total dipped hermetic motor Other features include: Centrifugal oil pump and low vibration and noise. Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured, this system has a cooling capacity to 55°F. The addition of an evaporator defrost control permits operation to 40°F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 30°F. Thermostats —Cooling only and heat/cooling (manual and automatic change over). Sub -base to match thermostat and locking thermostat cover. Evaporator Defrost Control — See Low Ambient Cooling. Accessory Description and Usage Anti -Short Cycle Timer — Solid state timing device that prevents compressor recycling until five (5) minutes have elapsed after satisfying call or power interruptions. Use in area with questionable power delivery, commercial applications, long lineset, etc. Evaporation Defrost Control — SPST Temperature actuated switch that cycles the condenser off as indoor coil reaches freeze-up conditions. Used for low ambient cooling to 30°F with TXV. Rubber Isolators — Five (5) large rubber donuts to isolate condensing unit from transmitting energy into mounting frame or pad. Use on any application where sound transmission needs to be minimized. Hard Start Kit — Start capacitor and relay to assist compressor motor startup. Use in areas with marginal power supply, on long linesets, low ambient conditions, etc. Extreme Condition Mount Kit — Bracket kits to securely mount condensing unit to a frame or pad without removing any panels. Use in areas with high winds, or on commercial roof tops, etc. AHRI Standard Capacity Rating Conditions AHRI Standard 210/240 Rating Conditions 1. Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB air entering outdoor coil. 2. High Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil. 3. Low Temperature Heating 17°F DB air entering indoor coil. 4. Rated indoor airflow for heating is the same as for cooling. AHRI Standard 270 Rating Conditions — (Noise rating numbers are determiend with the unit in cooling operations.) Standard Noise Rating number is at 95°F outdoor air. 4A7A3049A-SUB-1 B-E N ,��c icay s7 iw HEATING & AIR CONDITIONING Schematic Diagrams Figure 1. 3.5 and 4.0 Ton Model TO POWER SUPPLY PER UNIT NAMEPLATE AND LOCAL CODES I ----------1 CF FAN CAPACITOR -------I CN WIRECONMECTOR -START KIT CPR COMPRESSOR � BAYKSKT263 CR RUN CAPACITOR m I CS I r CS STARTING CAPACITOR CSR-I CSR I m CSR CAPACITOR SWITCHING RELAY -----1 MS-2 F INDOOR FAN RELAY �--0� RD-------- I BR a----BK/BL------ HPCO HIGH PRESSURE CUTOUT SWITCH 1 ________ _L 2_ 5_. R i LPCO LOW PRESSURE CUTOUT SWITCH CAPACITOR K BIII /BL IOL INTERNAL OVERLOAD PROTECTOR K _ _ _ SM SYSTEM ON -OFF SNITCH OD BR O R.) OL NS COMPRESSOR MOTOR CONTACTOR FAN PR MTR BK F C CPRODA OUTDOOR ANTICIPATOR OFT OUTDOOR FAN THERMOSTAT THERMALLY R- — - — - m ODS OUTDOOR TEMPERATURE SENSOR PROTECTED I ODT OUTDOOR THERMOSTAT INTERNALLY SC SWITCH OVER VALVE SOLENOID TDL DISCHARGE LINE THERMOSTAT TNS TRANSFORMER TYPICAL I I TYPICAL HPCO LPCO I I AIR HANDLER i THERMOSTAT I I d y I Y----+�--� I NOTES 182 I HEAT I I 1 (O(REMOT� W3 CONTROLSI ODT- I —I X2 -oo -BK - -_ W2---T-�i--- W2 `---BK-_J-- I � I ODT-A (OPTIONAL) I «—I—� WI --i— -- WI I I I I I �I I I I I �I B 24V I R ---I --RD-0 TO POWER SUPPLY PER LOCAL CODES----+—� I ® WARNING ® CAUTION HAZARDOUS VOLTAGE! USE COPPER CONDUCTORS ONLY! DISCONNECT ALL ELECTRICAL UNIT TERMINALS ARE NOT DESIGNED POWER INCLUDING REMOTE TO ACCEPT OTHER TYPES OF CONDUCTORS. DISCONNECTS BEFORE SERVICING. Failure to do so may cause damage Failure to disconnect power to fhe equipment. before servicing can cause severe personal injury or death. I —COLOR OF WIRE BK/BL ----COLOR OF MARKER BK BLACK RD RED OR ORANGE BL BLUE WIN WHITE GR GREEN BR BROWN YL YELLOW PR PURPLE PK PINK LTBL LIGHT BLUE NOTES: I. IF ODT-B IS NOT USED. ADD JUMPER BETWEEN W2 b W3 AT AIR HANDLER. IF USED. ODT-B NUST BE MOUNTED REMOTE OF CONTROL BOX IN AN APPROVED WEATHER PROOF ENCLOSURE. 2. IF ODT-A IS NOT USED. ADD JUMPER BETWEEN WI S W2 AT AIR HANDLER. 3. LOW VOLTAGE 124 V} FIELD WIRING MUST BE 18 AWG MIN. FOR CANADIAN INSTALLATIONS POUR INSTALLATIONS CANADIENNES CAUTION: NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 15OV-TO-GROUND ATTENTION:NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE PRINTED FROM D157362PO3 REV00 4A7A3049A-SUB-1 B-E N �I D9 In ersoll Rand Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands —including Club Car®, Ingersoll Rand®, Thermo King@ and Traneo—work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and efficiency. We are a global business committed to a world of sustainable progress and enduring results. 40)lngersoll Rand. T. THERMO KING 0 rAWE' ingersollrand.com cONus Intertek Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. 4A7A3049A-SUB-1B — EN 03mar2017 Supersedes 4A7A3049A-SUB-1A-EN (February 2017) ©2017 Ingersoll Rand I all rights reserved