Amw "s7izoda-d. HEATING & AIR CONDITIONING Specification Variable Speed Accul-ink" Heat Pump 4A6V0060A 1000A TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air- conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. September 2013 4A6V0060A-SPEC-1 ( Ingersoll Rand Akwe-aOS7iWOd4ldo HEATING & AIR CONDITIONING H LIQUID LINE SERVICE VALVE, "E" I.E. FEMALE BRAZED CONNECTION WITH 1/4" SAE FLARE PRESSURE TAP FITTING F GAS LINE SERVICE VALVE, "D" I.D. FEMALE FIG. 2 BRAZED CONNECTION ELECTRICALAND REFRIGERANT WITH 1/4" SAE FLARE COMPONENT CLEARANCES PRESSURETAP FITTING. PER PREVAILING CODES. J SERVICE PANEL-� G F GAS LINE SERVICEVALVE, "D" I. D. FEMALE BRAZED CONNECTION WITH 1/4" SAE FLARE PRESSURE TAP FITTING. l:l G--I�_ LIQUID LINE SERVICE / FIG. 3 VALVE, "E" I.D. FEMALE J BRAZED CONNECTION WITH 1/4" SAE FLARE PRESSURE TAP FITTING. K ELECTRICAL SERVICE PANEL TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524(5 FEET) ABOVE UNIT. UNIT SHOULD BE PLACED SO ROOF RUN-OFFWATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 305112") FROM WALL AND ALL SURROUNDING SHRUBBERY ONTWO SIDES. OTHER TWO SIDES UNRESTRICTED 22.2 (7/8) DIA. HOLE LOW VOLTAGE 28.6 0 -1/8) DIA. K.O. WITH 22.2 (718) DIA. HOLE IN CONTROL BOX BOTTOM FOR ELECTRICAL POWER SUPPLY LIQUID LINE SERVICE VALVE, I.D. FEMALE .E" qF1' BRAZE CONNECTION WITH1/4"SAE FLARE PRESSURETAP FITTINGS K.O. FOR ALTERNATE ELECTRICAL ROUTINGFIG. 'I GAS LINE 114TURN BALL SERVICEVALVE, .pA I.D. FEMALE BRAZED CONNECTION WITH 1/4 SAE FLARE PRESSURETAP FITTING. A Model Base A B C D E F G H I K 1147 946 870 127 76 197 57 813 4A6V0060A 4 (45-1/8) (37-1/4) (34-1/4) 22-7/8 10-3/8 (5) (3) (7-3/4) (2-1/4) (32) SOUND POWER LEVEL Model Mode Speed A -Weighted Sound Power Level [dB(A)] 63 Hz 125 Hz 250 Hz Full Octave Sound Power[dB] 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4A6V0060A Cool Min 57 69.7 59.5 57.6 55.1 52.0 45.0 41.6 42.3 Cool Max 73 83.9 73.7 73.1 71.2 67.9 64.4 58.9 51.8 Heat Min 61 71.9 61.3 59.0 61.3 56.2 48.7 45.1 45.5 Heat I Max 1 74 85.8 75.7 74.4 73.2 68.5 63.6 59.6 55.9 Note: Rated in accordance with AHRI Standard 270-2008 2 4A6V0060A-SPEC-1 74*6f eAW S*uwd"d HEATING & AIR CONDITIONING OUTDOOR UNIT (a) (b) 4A6V0060A1000A POWER CONNS. — V/PH/HZ (_) 208/230/1/60 MIN. BRCH. CIR. AMPACITY 37.0 BR. CIR. PROT. RTG. — MAX. (AMPS) 50 COMPRESSOR SCROLL NO. USED — NO. SPEEDS 1—VARIABLE R.L. AMPS (d) — L.R. AMPS 27.5 — 12.0 FACTORY INSTALLED START COMPONENTS (e) NA INSULATION/SOUND BLANKET YES COMPRESSOR HEAT YES OUTDOOR FAN DIA. (IN.) — NO. USED 27.5 — 1 TYPE DRIVE — NO. SPEEDS DIRECT— VARIABLE CFM @ 0.0IN. W.G. M 4757 NO. MOTORS — HP 1-1/3 MOTOR SPEED R.P.M. 200 — 1200 VOLTS/PH/HZ 208/230/1/60 F.L. AMPS 2.8 OUTDOOR COIL — TYPE SPINE FINT`" ROWS—F.P.I. 1-24 FACE AREA (SQ. FT.) 30.80 TUBE SIZE (IN.) 3/8 REFRIGERANT R410—A LBS. — R-410A (O.D. UNIT) (g) 11 lb — 14 oz FACTORY SUPPLIED YES LINE SIZE — IN. O.D. GAS (h) 1-1/8 LINE SIZE — IN. O.D. LIQ. (1) 3/8 CHARGING SPECIFICATIONS SUBCOOLING 10, DIMENSIONS H X W X D CRATED (IN.) 51 X 35.1 X 38.7 WEIGHT SHIPPING (LBS.) 276 NET (LBS.) 250 (a) Certified in accordance with the Air -Source Unitary Air -conditioner Equipment certification program, which is based on AHRI standard 210/240. (b) Rated in accordance with AHRI standard 270. (0 Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers or fuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. (e) No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter. M Standard Air — Dry Coil — Outdoor (e) This value approximate. For more precise value see unit nameplate. (h) Max length of refrigerant lines from outdoor to indoor unit MUST NOT exceed 80 feet. The max vertical change MUST NOTexceed 10 feet. If 7/8" suction line is used, see footnote (i). (1) Max. linear length 150 ft,; Max. lift - Suction 50 ft,; Max. lift - Liquid 50 ft. Mechanical Specification Options General The Outdoor Units are charged from the factory for matched indoor section and up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures from 55' F to 120' F in cooling and from —10' F to 66' F in heating. Only AHRI approved indoor matches are approved for use with these models. AccuLinkTM' This outdoor unit contains the AccuLinkT" digital communication with 2 wire connection to outdoor and Plug-n-Play set up. Casing Unit casing is constructed of heavy gauge. G60 galvanized steel and painted with a weather -resistant powder paint on all louvers, panels, prepaint on all other panels. Corrosion and weatherproof CMBP-G30 DuraBaseT' base. Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and high and low pressure switches. A factory supplied, field installed filter is standard. Compressor Inverter driven scroll compressor with 25 to 100% output capacity on heat pumps and 30 to 100% output capacity on air conditioners. Noise enclosure minimizes sound levels and built in compressor protection protects compressor will reduce operating speed and current draw to maintain operation while protecting the compressor. Condenser Coil The Spine FinTM outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured, this system has built in freeze protection that will allow cooling operation below 55°F but will reduce capacity or shut down completely to prevent operation under adverse conditions. Comfort Control The 950/850 Control is required and provides Plug-n- Play setup and 3 wire connection. 4A6V0060A-SPEC-1 ETA us ��STEO Intertek Atmmg-� shw,dvd® HEATING & AIR CONDITIONING American Standard optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, American Standard offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.americanstandardair.com. American Standard has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. ©2013 American Standard Heating & Air Conditioning An) 4A6V0060A-SPEC-1 13 Sep 2013 Ingersoll Rand Supersedes(New)