CANOD FormApplicant:
CHARLES WRIGHT
Property Owner:
NORTHWEST CARE SENIOR
LIVING
Critical Area File #:
CRA2020-0095
Permit Number:
BLD2020-0734
Site Location:
728 EDMONDS WAY
Parcel Number:
27032500306000
Project Description:
ROSEWOOD COURTE- ALTER SHED TO ADD 4 BEDA BATH P&M SEP.
X Conditional Waiver. No critical area report is required for the project described above.
There will be no alteration of a critical area.
X The proposal is an allowed activity pursuant to ECDC
23.40.220, 23.50.020, and/or 23.80.040.
The proposal is exempt pursuant to ECDC 23.40.230.
Erosion Hazard. Project is within erosion hazard area. Applicant must prepare an erosion and sediment control
plan in compliance with ECDC 18.30.
Critical Area Report The project is within a critical area and/or critical area buffer and a report has been evaluated for
Required. compliance with applicable criteria.
X Favorable Critical Area The proposed project as described above and as shown on the attached site plan meets or is
Decision exempt from the criteria in ECDC 23.40.160, Review Criteria, and complies with the applicable
provisions of the City of Edmonds critical area regulations. Any subsequent changes to the
proposal shall void this decision pending re -review of the proposal.
Conditions. Critical area specific condition(s) have been applied to the permit number referenced above.
See referenced permit number for specific condition(s).
Notice on Title. Critical area notice on title recorded under AFN .
Reviewer MICHELE Q. SZAFRAN Date 1/12/2021
Appeals: Any decision to approve, condition, or deny a development proposal or other activity boased on the requirements of
critical area regulations may be appealed according to, and as part of, the appeal procedure, if any, for the permit or approval
involved.
a
WRIGHT ARCHITECTURE
PLANTER STRIP
CONCRETE CURB AND GUTTER
EXIST. SIDEWALK
DEMO EXISTING GATE. RELOCATE
ELECTROMAGNETIC LOCKING
EGRESS DEVICE TO NEW GATE
EXIST. CONCRETE CURB
AND GUTTER
EXIST SIDEWALK
EXIST TREES TO REMAIN
NEW ROOF EDGE
NEW HVAC PER MECH
O
/ r 1 G1 RELOCATE ELECTROMAGNETIC LOCKING /;:.. /
DEMO EXIST FENCE AND J Y L -:: EGRESS DEVICE. INSTRUCTIONS FOR
GATES SHOWN DASHED k :: EXITING ON COURTYARD SIDE OF GATE
/
r
P113
DEMO EXIST CONC WALKS / NEW 6' HIGH WOOD FENCE G1
/ . TO MATCH EXIST, RE: 6/A7.4 /
SHOWN SHADED, 696 SF.............
NEW WOOD GATE, RE: 9 A7.4
EXIST 6' HIGH WOOD„'' \ :::::::$::
REMOVE EXIST TREE
FENCE TO REMAIN
co
,M E - TANK MAN HOLE ACCESS M/
/
DETENTION VAULT MAN .,
HOLE ACCESS TO REMAIN t* ::: .:. � � - � TO REMAIN ACCESSIBLE / R
E
� /
DEMO EXIST CONC SLAB o
SHOWN SHADED, 500 SF 5 FEET SETBACK REQUIRING M
/ /
/ f: FIRE PROTECTION �,
w
3�
VFy // // k . I NEW 4' WIDE PERVIOUS CONC
i :: ` ::; ::::::::: l / t ; 1 ■_ WALKS SHOWN SHADED 466 SF
........:::
EVA�T 6 HIG�7 1
TO REMAIN I WOOD FENCE
DETENTION VAULT / // \ \ / -(>E
I MAN HOLE ACCESS - -
TO REMAIN °
\ J
I"
E
� I
NOTE: \ �
TOTAL AREA NON -PERVIOUS L
SURFACE AREA REMOVED,
1196 SF Try -
PARTIAL SITE PLAN - DEMOLITION
199 = 20'-0"
FEET
0 10 0
Plan North True North
TANK MAN HOLE ACCESS / ` / -
❑ 20, J
EXIST DETENSION TANK CB
V 7 I
_(�'E I
NOTE:
TOTAL NEW AND REPLACED
NON -PERVIOUS AREA, 2,451 SF
(ROAD PLANTER STRIP)
/F-6 FOOT CONSTRUCTION FENCE AT
DRIP LINE OF EXIST TREES
EDMONDS
WAY
�04
S38° 55'01 "E
E*
15'
BUILDING SETBACK LINE
--------------
° I
-------
I
L_
J ------------J
I
yj
I
L-�
E�
■0 Orr " M40.1 0
60'-0" EXIST.
18'-0"
24'-0"
w Q
U w
I C
;n N
N 1
cy00
uj
00 Q
,n
W
1
�
co
1
E
_
00
I
Q
M
�
N
w
U
n
o_
E
(n
a
p
II
a
w
I
00
o a
I +
ui
W VAN STORAGE
Q I >
CL
V)
� ❑ PLANTING Q
00 CB
�
1 ,�
N [n
EXISTING FIRE HYDRANT BENCH
MARK. TOP OF OPERATING NUT
EL = 101.71
RE -SURFACE EXISTING
ASPHALT DRIVE
REPAINT INTERNATIONAL
ACCESSIBLITY SYMBOLS, BLUE
REPAINT ALL PARKING
SPRIPING, WHITE
EXIST CONC CURBS TO REMAIN
1
SEE ILEET A 1.2 FOR APPROVED LANDSCAPINC
PAINT LETTERS 12" HIGH,
4" STROKE, YELLOW,
FIRE LANE STRIPING, 4"
WIDE, YELLOW
PAINT LETTERS 12" HIGH,
4" STROKE, YELLOW
PAINT FIRE LANE STRIPING,
q ! I I MIN. 4" WIDE, YELLOW
—J ❑ � x
I E_('� 3 W
---------- I \ M ,
\ I DETENTION ULT co
\ I I I I VACUUM TRU ^
L--------------J L_-------- STAGING__AREA- _ ��_ 10'-0' BUFFER
�E 0E �E v,
\ TOE OF HILL
El
E
CB ❑ _
\ CB , , _ - PAINT FIRE LANE PERIMETER
EXIST PROPANE STRIPING, 4" WIDE, YELLOW,
�_ ------------ /
- - -' FUEL TANK SYMBOL LEGEND
EXIST TRASH D DEMOLISH AND/OR RELOCATE
ENCLOSURE
15' BUILDING SETBACK LINE FROM W/6'-0" FENCE
\ E EXISTING
ADJACENT RESIDENTIAL ZONED
\ \ PROPERTY EXIST EMERGENCY
GENERATOR N NEW
EXIST ROCKERY ' R RELOCATE OR REPLACE
\ PROPERTY LINE NOTES TO DRAWING:
\
1. COORDINATE LAYOUT OF PATIOS AND CURVED PATHS WITH
ARCHITECT, INCLUDING LOCATION OF CONTROL JOINTS AND
EXPANSION JOINTS.
2. PAVED WALKWAYS TO HAVE CONTROL JOINTS (CJ) AT
"i\ \ 5'-0" O.C. MAX.
3• PAVED WALKWAYS TO HAVE EXPANSION JOINTS (EJ) AT
` 20'-0" O.C. MAX.
` \ I
4. VERIFY LOCATION OF EXISTING SITE LIGHTING. COORDINATE
LOCATION OF FIXTURES SHOWN HERE WITH LOCATION OF
` \ EXISTING FIXTURES AND COORDINATE WITH ARCHITECT.
DRAWING LEGEND:
E SITE LIGHT FIXTURE - EXISTING TO REMAIN
` N SITE LIGHT FIXTURE - NEW
1 R SITE LIGHT FIXTURE - EXISTING RELOCATED
PARKING REQUIREMENTS:
` \ 1
48 EXISTING BEDS
53 BEDS PROPOSED
\ \ 53 BEDS/ (1 SPACE/3 BEDS) = 18 SPACES REQUIRED
23 SPACES PROVIDED AT 8'-6" X 18'-0"
\ 1 ADDITIONAL VAN STORAGE SPACE
SITE PLAN Plan North
1 1 ff = 20'-099
F
0 0 0EET
True North
3802 29 TH AVENUE WEST
SEATTLE WASHINGTON 98199
charles@wrightarch.com 206.285.7167
9023 REGISTERED
ARCHI ECT
CHARLES C. WRI HT
STATE OF WASHINGTON
(n
z
0
F_
oC
Q
Q
o
Q>_
U
N
o
00
Q
}
0')Q
z
2
LU
<
3:
0
2
Cr)
ZLU�
z
Z
=
0U
�
J
w
O
�
Z
Z
W
p
W
O
W
Ir
cf)
W
DATE:
PERMIT - EDMONDS / DOH CRS 07-13-2020
PERMIT - DOH CRS / REV 1 10-18-2020
PERMIT - EDMONDS / REV 1 12-01-2020
SHEET TITLE: