BLD2020-0614+Architectural_Plan+6.15.2020_11.01.56_AMSIECKE- TROWBRIDGE
REMODEL
16740 76th Ave W
Edmonds, WA 98026
06/15/2020
PERMIT SET
SHEET INDEX - PERMIT SET
Sheet Filter Sheet No. SHEET NAMES
GENERAL
A0.00 GENERAL INFORMATION
A0.01 2015 IRC CODE INFORMATION
ARCHITECTURAL
A2.00 LOWER LEVEL DEMO & FLOOR PLAN
A2.10 MAIN LEVEL DEMO & FLOOR PLAN
A2.20 UPPER LEVEL DEMO & FLOOR PLAN
A3.00 EXTERIOR ELEVATIONS & SCHEDULES
A3.10 BUILDING SECTIONS & ELEVATIONS
STRUCTURAL
S1.0 GENERAL NOTES
S2.0 FRAMING PLAN
S3.0 STRUCTURAL DETAILS
RECEIVED
Jun 16 2020
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
City Of Edmonds
Building Department
Work___________________________________________________________________
Address________________________________________________________________
Owner__________________________________________________________________
Approved Date___________________________________________________________
Building Official___________________________________________________________
Permit Number
_______________________________________________________________________
BLD2020-0614
REMODEL
167400 76TH AVE W
SIECKE-TROWBRIDGE
OBTAIN ELECTRICAL PERMIT FROM
STATE LABOR & INDUSTRIES
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
CITY OF EDMONDS
BUILDING DIVISION
APPROVED PLAN
APPROVED
PLANS MUST BE
ON JOB SITE
7/02/2020Donovan W. K Akau
XX
GARAGE
G101
REFERENCE CONSTRUCTION MEMO ISSUING REVISION.
ONLY MOST RECENT REVISION SHOWN CLOUDED.
REFERENCE FOR PREVIOUS REVISIONS REMAIN.
DATE OF REVISIONS INDICATED AT RIGHT MARGINS.
ELEV. 0.00
A100.11. GRID LINE REFERENCE
ABBREVIATIONS
320 SF
N
A3.00
1
3
1
AX.XX4 2
2
1
4
A4.00
@ AT
CENTERLINE
PROPERTY LINE
DIAMETER
# POUND OR NUMBER
(E) EXISTING
(N) NEW
AB ANCHOR BOLT
ABV ABOVE
ACC ACCESS
ACOUS ACOUSTICAL
ACP ASPHALT CONCRETE PAVING
ACS ACCESS PANEL
ACT ACOUSTICAL TILE
AD AREA DRAIN
ADA AMERICANS with DISABILITIES
ADJ ADJUSTABLE
AFF ABOVE FINISHED FLOOR
AGGR AGGREGATE
AIB AIR INFILTRATION BARRIER
ALT ALTERNATE
ALUM ALUMINUM
APPROX APPROXIMATE
ARCH ARCHITECTURAL
ASPH ASPHALT
AUTO AUTOMATIC
BD BOARD
BITUM BITUMINOUS
BLDG BUILDING
BLKG BLOCKING
BM BEAM
BO BOTTOM OF...
BOT BOTTOM
BRG BEARING
BSMT BASEMENT
BUR BUILT UP ROOFING
CAB CABINET
CB CATCH BASIN
CEM CEMENT
CER CERAMIC
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CLG CEILING
CLK CAULKING
CLO CLOSET
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CNTR COUNTER
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
CORR CORRIDOR
CPT CARPET; CARPETED
CRS COLD ROLLED STEEL
CSK COUNTERSUNK
CT CERAMIC TILE
CTR CENTER
CU FT CUBIC FEET
DBL DOUBLE
DEMO DEMOLITION
DET DETAIL
DIA DIAMETER
DIM DIMENSION
DL DEAD LOAD
DN DOWN
DR DOOR
DR OPNG DOOR OPENING
DS DOWNSPOUT
DSP DRY STANDPIPE
DT DRAIN TILE
DW DISHWASHER
DWG DRAWING
E EAST
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
ENCL ENCLOSURE
EQ EQUAL
EQUIP EQUIPMENT
EST ESTIMATE
EW EACH WAY
EXH FN EXHAUST FAN
EXIST EXISTING
EXP EXPANDED; EXPANSION
EXP BT EXPANSION BOLT
EXPO EXPOSED
EXT EXTERIOR
FA FIRE ALARM
FB FLAT BAR
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF EL FINISH FLOOR ELEVATION
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FIN FLR FINISH FLOOR
FF FINISH TO FINISH
FIN FINISH
FLASH FLASHING
FLR FLOOR; FLOORING
FLUOR FLUORESCENT
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOIC FURNISHED BY OWNER -
INSTALLED BY CONTRACTOR
FOM FACE OF MASONRY
FOS FACE OF STUDS
FP FIREPROOF
FPL FIREPLACE
FR FRAME
FT FOOR OR FEET
FTG FOOTING
FURR FURRING
FUT FUTURE
FW FULL WIDTH
GA GAUGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GL GLASS
GLAM GLUE-LAMINATED
GR GRADE
GWB GYPSUM WALL BOARD
GYP GYPSUM
HB HOSE BIBB
HC HOLLOW CORE
HDO HIGH DENSITY OVERLAY
HDR HEADER
HDWD HARDWOOD
HDW HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HP HIGH POINT
HR HOUR
HT HEIGHT
HVAC HEATING/VENTILATING/AIR
CONDITIONING
HW HOT WATER
HWT HOT WATER TANK
ID INSIDE DIAMETER
IN INCH
INCL INCLUDED
INSUL INSULATION
INT INTERIOR
INV INVERT
JB JUNCTION BOX
JF JOINT FILLER
JT JOINT
KIT KITCHEN
KO KNOCKOUT
LAM LAMINATE, LAMINATED
LAV LAVATORY
LBS POUNDS
LF LINEAR FOOT (FEET)
LH LEFT HAND
LL LIVE LOAD
LOC LOCATION
LP LOW POINT
LT LIGHT
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MB MACHINE BOLT
MC MEDICINE CABINET
MDF MEDIUM DENSITY FIBERBOARD
MDO MEDIUM DENSITY OVERLAY
MECH MECHANICAL
MEMB MEMBRANE
MEZZ MEZZANINE
MFR MANUFACTURER
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
MO MASONRY OPENING
MTD MOUNTED
MTL METAL
MUL MULLION
N NORTH
N/A NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NR NOISE REDUCTION
NTS NOT TO SCALE
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OVERFLOW DRAIN
OFF OFFICE
OH OVERHEAD
OHWM ORDINARY HIGH WATER MARK
OPNG OPENING
OPP OPPOSITE
OSB ORIENTED STRAND BOARD
PBD PARTICLE BOARD
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PERF PERFORATED
PERP PERPENDICULAR
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLWD PLYWOOD
PNL PANEL
PNT POINT
PR PAIR
PRCST PRECAST
PSF POUNDS PER CUBIC FOOT
PSI POUNDS PER SQUARE INCH
PT PRESERVATIVE TREATED
PTN PARTITION
PVC POLYVINYL CHLORIDE
R RISER
RA RETURN AIR
RAD RADIUS
RD ROOF DRAIN
REF REFERENCE
REFR REFRIGERATOR
REG REGISTER
REINF REINFORCED
REM REMAINDER
REQ REQUIRED
RESIL RESILIENT
REV REVISION; REVISIONS; REVISED
RH RIGHT HAND
RM ROOM
RO ROUGH OPENING
RWL RAIN WATER LEADER
S SOUTH
SAF SELF-ADHERED FLASHING
SAM SELF-ADHERED MEMBRANE
SC SOLID CORE
SCHED SCHEDULE
SD SMOKE DETECTOR
SECT SECTION
SG SAFETY GLASS
SHV SHELF; SHELVING
SHR SHOWER
SHT SHEET
SHT MTL SHEET METAL
SHTG SHEATHING
SIM SIMILAR
SOG SLAB ON GRADE
SPEC SPECIFICATION
SQ FT SQUARE FOOT (FEET)
SQ IN SQUARE INCH(ES)
SST STAINLESS STEEL
STD STANDARD
STL STEEL
ST STONE
STOR STORAGE
STRUCT STRUCTURAL
SUSP SUSPENDED
SYM SYMMETRICAL
T TREAD
T&G TONGUE AND GROOVE
TEL TELEPHONE
TER TERRAZZO
TG TEMPERED GLASS
THK THICK
TO TOP OF...
TOB TOP OF BEAM
TOC TOP OF CONCRETE; CURB
TOF TOP OF FLOOR; FOOTING; FRAME
TOM TOP OF MASONRY
TOP TOP OF PARAPET; PAVEMENT
TOPO TOPOGRAPHY
TOS TOP OF SLAB; STEEL
TOW TOP OF WALL
TS TUBE STEEL
TSTAT THERMOSTAT
TYP TYPICAL
UNO UNLESS OTHERWISE NOTED
VB VINYL BASE
VEN VENEER
VERT VERTICAL
VEST VESTIBULE
VG VERTICAL GRAIN
VIF VERIFY IN FIELD
VT VINYLT TILE
W WEST
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
WDW WINDOW
WF WIDE FLANGE
WF BM WIDE FLANGE BEAM
WG WIRED GLASS
WH WATER HEATER
WL WATER LINE
WLD WELDED
WP WATERPROOF
WPM WATERPROOF MEMBRANE
WR WATER RESISTANT
WSCT WAINSCOT
WSG WIRE SAFETY GLASS
WTR WATER
WWF WELDED WIRE FABRIC
WWM WELDED WIRE MESH
WT WEIGHT
A
2. ROOM REFERENCE ROOM NAME
ROOM NUMBER
3. DOOR REFERENCE
REFERENCE DOOR
SCHEDULE
4. WINDOW / SKYLIGHT REFERENCE
5. ELEVATION / DATUM REFERENCE
TO
6. EXTERIOR ELEVATION
7. BUILDING SECTION
4
A4.108. WALL SECTION
DRAWING NUMBER
SHEET NUMBER
DRAWING NUMBER
SHEET NUMBER
DRAWING NUMBER
SHEET NUMBER
9. INTERIOR ELEVATION
10. DETAIL REFERENCE XX
AX.XX
DRAWING NUMBER
SHEET NUMBER
11. ASSEMBLY REFERENCE
12. NORTH SYMBOL
13. REVISION REFERENCE
SYMBOLS LEGEND
MATERIALS LEGEND
ZONING / BUILDING CODE SUMMARY
PROJECT ADDRESS:
16740 76th Ave W
Edmonds, WA 98026
ASSESSOR'S PARCEL NUMBER:
00693100001200
LEGAL DESCRIPTION:
BROOKACRES ESTATES, REPLAT OF BLK 000 D-00 LOT 12
APPLICABLE CODES:
2015 INTERNATIONAL RESIDENTIAL CODE
2015 MECHANICAL CODE
2015 INTERNATIONAL FIRE CODE
2015 UNIFORM PLUMBING CODE
2014 NATIONAL ELECTRICAL CODE
AUTHORITY HAVING JURISDICTION:
City of Edmonds
PHYSICAL ADDRESS:
Development Services Department
121 5th Ave N
Edmonds, WA 98020
BUILDING:
425-771-0220
LAND USE:
425-771-0220
ELECTRONIC MAIL:
OnlinePermits@edmondswa.gov
LOT SIZE:
0.13 ACRES
LAND USE DESIGNATION:
Residential - RS-12
DENSITY:
3.7
MAXIMUM SITE COVERAGE: 35%
PROJECT DESCRIPTION:
INTERIOR REMODEL OF KITCHEN AND LIVING ROOM TO INCLUDE
STRUCTURAL MODIFICATION OF WALL AND ADDITIONAL SUPPORT AT
LOWER LEVEL. EXTERIOR ALTERATIONS INCLUDE REPLACEMENT OF
ENTRY DOOR AND ADJACENT CLERESTORY AND SIDELITES AND THE
REPLACEMENT OF SIX EXISTING WINDOWS. EXTERIOR ALTERATIONS
ALSO INCLUDE THE MODIFICATION OF EXTERIOR ENVELOPE ADJACENT
TO OPENINGS TO ACCOMODATE NEW WINDOW SIZES.
HEIGHT:
ALLOWED: 25'
PROPOSED: N/A
YARD SETBACKS:
SIDE: 10'
REAR: 25'
STREET: 25'
ENERGY CODE COMPLIANCE:
2015 WASHINGTON STATE ENERGY CODE - REMODEL
VERTICAL GLAZING: MAX. U VALUE = 0.30
DOOR U-FACTOR: MAX. U VALUE = 0.30
CEILING: R-49
WALLS ABOVE GRADE: 2x4 stud walls: R-15
2x6 stud walls: R-21
FLOOR CAVITIES: R-30
VICINITY MAP
NOT TO SCALE
LOCATION MAP
NOT TO SCALE
GENERAL NOTES
1. CODES: ALL WORK SHALL CONFORM APPLICABLE LAND USE AND
BUILDING CODES AS AMENDED BY AUTHORITIES HAVING
JURISDICTION.
2. DO NOT SCALE DIMENSIONS FROM DRAWINGS. USE CALCULATED
DIMENSIONS ONLY. NOTIFY THE ARCHITECT IMMEDIATELY IF ANY
CONFLICTS EXIST.
3. CONTRACTOR SHALL VERIFY ALL CONDITIONS PRIOR TO INITIATING
THE WORK. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.
4. VERIFY ALL ROUGH-IN DIMENSIONS FOR EQUIPMENT. PROVIDE ALL
BUCK-OUT, BLOCKING, BACKING, AND JACKS REQUIRED FOR
INSTALLATIONS.
5. DIMENSIONS ARE TO EXTERIOR FACE OF CONCRETE / WOOD
FRAMING UNLESS OTHERWISE NOTED.
6. EXTERIOR WALL FRAMING 2x6 WOOD STUDS UNLESS OTHERWISE
NOTED.
7. INTERIOR WALL FRAMING 2x4 WOOD STUDS UNLESS OTHERWISE
NOTED.
PROJECT DIRECTORY
SITE ADDRESS:
16740 76th Ave W
Edmonds, WA 98026
OWNER:
Neil Siecke & Janet Trowbridge
16740 76th Ave W
Edmonds, WA 98026
ARCHITECT:
ESTATE HOMES
16300 Mill Creek Blvd #121
Mill Creek, WA 98012
T: 425.743.3373
PRINCIPAL ARCHITECT: CJ Christensen
cj@estatehomes.net
CONTACT: Jamie Blackard
jamieb@estatehomes.net
STRUCTURAL ENGINEER:
Nickerson Engineering
2221 Everett Ave. #202
Everett, WA 98201
T: 425.610.4425
CONTACT: Chris Nickerson
chris@nickersonengineering.com
CONTRACTOR
ESTATE HOMES
16300 Mill Creek Blvd #121
Mill Creek, WA 98012
T: 425.743.3373
CONTACT: C.J. Christensen
cj@estatehomes.net
CL
PL
O/
1 DRAWING NUMBER
SHEET NUMBER
WOOD BLOCKING SHIM
FINISHED WOOD
BATT INSULATION
GRAVEL
STEEL
CMU
WOOD FRAMING (CONTINUOUS)
PLYWOOD
RIGID INSULATION
EARTH
ALUMINUM
STONE
BRICK
CONCRETE
MINERAL INSULATION FOAMED IN PLACE INSULATION project:principal architect
project manager
drawn by
checked by
job no.
date
date
revisions:
b
y
no.
06/15/2020
GENERAL
INFORMATION
A0.00SIECKE-TROWBRIDGEREMODEL16740 76th Ave WEdmonds, WA 98026CJC
LD
JGB
SIECKE
06/15/2020
PERMIT SET
RECEIVED
Jun 16 2020
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
APPROVED
PLANS MUST BE
ON JOB SITE
OBTAIN ELECTRICAL PERMIT FROM
STATE LABOR & INDUSTRIES
CITY OF EDMONDS
BUILDING DIVISION
APPROVED PLAN
SITE WORKGENERALUNLESS A SOILS INVESTIGATION REPORT BY A LICENSED SOILS ENGINEER IS PROVIDED, THE FOUNDATION DESIGN IS BASED UPON AN ASSUMED AVERAGE SOIL BEARING CAPACITY OF 1,500 PSF. EXTERIOR FOOTINGS SHALL BEAR 1'-6" MINIMUM BELOW FINISHED GRADE. ALL FOOTINGS TO BEAR ON FIRM, UNDISTURBED EARTH BELOW ORGANIC SURFACE SOILS. ALL BACK FILL MATERIAL SHALL BE THOROUGHLY COMPACTED. FOUNDATION VENTS SHALL NOT INTERFERE WITH DIRECT LOAD PATH OF COLUMNS.GENERALPLANS COMPLY TO THE 2015 INTERNATIONAL RESIDENTIAL CODE.CONTRACTOR SHALL VERIFY ALL NOTES, DIMENSIONS AND CONDITIONS PRIOR TO CONSTRUCTION. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING AS REQUIRED UNTIL ALL PERMANENT CONNECTIONS HAVE BEEN MADE. IT IS THE CONTRACTORS RESPONSIBILITY TO IDENTIFY ALL DISCREPANCIES TO THE ARCHITECT AT THE TIME THEY ARE NOTED. DIMENSIONS TAKE PRECEDENCE OVER SCALED DRAWINGS.CODES:ALL APPLICABLE CODES AND AUTHORITIES HAVING JURISDICTION SHALL BE FOLLOWED1. 2015 INTERNATIONAL RESIDENTIAL CODE (IRC) 2. 2015 INTERNATIONAL BUILDING CODE (IBC)3. 2015 INTERNATIONAL EXISTING BUILDING CODE (IEBC) 4. 2015 INTERNATIONAL MECHANICAL CODE (IMC)5. 2015 INTERNATIONAL FUEL GAS CODE (IFGC)6. 2015 UNIFORM PLUMBING CODE (UPC) 7. 2015 INTERNATIONAL FIRE CODE (IFC) 8. 2015 WASHINGTON STATE ENERGY CODE (WSEC). BUILDINGCONSTRUCTION TYPE: V-B OCCUPANCY GROUP: R-3LOCAL JURISDICTION REQUIRES DWELLING UNIT FIRE SPRINKLER SYSTEM PER 1RC APPENDIX RYESNOGROUND SNOW LOADWIND DESIGNSPEED(MPH)TOPO-GRAPHIC EFFECTSSEISMIC DESIGN CATEGORYSUBJECT TO DAMAGE FROMWEATHERINGFROST LINE DEPTHTERMITEGENERALMINIMUMCLASS AND USE F'C SLUMP SACKS / C.Y.A.FOOTINGS 2500 3-4 5-1/2B.SLABS ON GRADE 2500 3-4 5-1/21. AIR ENTRAINING AGENT (5% TO 7%) TO BE USED IN ALL CONCRETE FLAT WORK EXPOSED TO WEATHER.2. POZZOLITH 300 SERIES (4 oz. PER 100# OF CEMENT) TO BE USED IN ALL CONCRETE.3. MIX MAY BE DESIGNED IN ACCORDANCE WITH THE PROVISIONS OF THE 2012 IBC/IRC.4. WATER TO CEMENT RATIO PER THE 2012 IBC/IRC.REINFORCING STEELASTM A615 GRADE 40, REINFORCING STEEL DETAILS SHALL BE PREPARED BY AN EXPERIENCED APPROVED DETAILER AND CONFORM TO STANDARD PRACTICE OUTLINED IN ACI REPORT 315.CONCRETE COVER OF REINFORCING STEEL3" CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH.1-1/2" CONCRETE EXPOSED TO EARTH OR WEATHER.1-1/2" BEAMS AND COLUMNS NOT EXPOSED TO EARTH OR WEATHER.3/4" SLABS AND WALLS NOT EXPOSED TO EARTH OR WEATHER.CONCRETEGENERALALL FRAMING SHALL COMPLY WITH THE APPROPRIATE SECTION(S) OF THE 2012 IBC/IRC. PRESSURE TREATED WOOD REQUIRED IN LOCATIONS LISTED IN IRC R317.12" MINIMUM VERTICAL CLEARANCE BETWEEN WOOD & CONCRETE STEPS, PORCH SLABS, PATIO SLABS & OTHER SIMILAR HORIZONTAL SURFACES EXPOSED TO THE WEATHER.6" MINIMUM CLEARANCE BETWEEN WOOD SIDING, SHEATHING AND WALL FRAMING ON EXTERIOR OF THE BUILDING AND EARTH.8" MINIMUM CLEARANCE BETWEEN UNTREATED MUDSILLS AND EARTH.12" MINIMUM CLEARANCE BETWEEN FLOOR BEAMS AND EARTH.18" MINIMUM CLEARANCE BETWEEN FLOOR JOISTS AND EARTH.LOADINGROOF 15 PSF DEAD LOAD + 20 PSF LIVE LOAD = 35 PSFFLOOR 10 PSF DEAD LOAD + 40 PSF LIVE LOAD = 50 PSFCEILING 5 PSF DEAD LOAD + 10 PSF LIVE LOAD = 15 PSFDECK 5 PSF DEAD LOAD + 40 PSF LIVE LOAD = 45 PSF INTERIOR PARTITION = 7 PSF EXTERIOR PARTITION = 10 PSF WOOD BEARING ON OR INSTALLED WITHIN 1/2" OF MASONRY OR CONCRETE TO BE TREATED WITH AN APPROVED PRESERVATIVE. SOLID BLOCKING OF NOT LESS THAN 2x THICKNESS SHALL BE PROVIDED AT ENDS AND AT ALL SUPPORT OF JOISTS AND RAFTERS. ANCHOR BOLTS TO BE PER SHEAR WALL SCHEDULE AND FOUNDATION PLAN. 7" MINIMUM EMBEDMENT. ALL METAL FRAMING ANCHORS AND HANGERS SHOWN ON DRAWINGS SHALL BE STRONG TIE CONNECTORS AS MANUFACTURED BY SIMPSON COMPANY.PROVIDE FIREBLOCKING IN CONCEALED SPACES OF STUD WALLS & PARTITIONS, INCLUDING FURRED SPACES & PARALLEL ROWS OF STUDS OR STAGGERED STUDS AS FOLLOWS:1. VERTICALLY AT THE CEILING & FLOOR LEVELS.2. HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FEET.PROVIDE FIREBLOCKING AT OTHER LOCATIONS PER 2015 IRC R302.11.PLYWOODALL PLYWOOD WALL AND ROOF SHEATHING SHALL BE 1/2" CDX, UNLESS NOTED OTHERWISE. MINIMUM NAILING SHALL BE 8d @ 6" O.C. AT PANEL EDGES AND 12" O.C. IN FIELD. SPAN INDEX SHALL BE 24/0. ALL PLYWOOD FLOOR SHEATHING SHALL BE 3/4" CDX TONGUE & GROOVE UNLESS NOTED OTHERWISE. MINIMUM NAILING SHALL BE 10d @ 6" O.C. @ PANEL EDGES AND 12" O.C. IN FIELD. SPAN INDEX SHALL BE 40/20. STAGGER ALL PANEL EDGES AT ROOF AND FLOOR SHEATHING. ORIENTED STRAND BOARD (O.S.B.) SHEATHING PRODUCTS OF EQUIVALENT SPAN RATINGS SHALL BE ALLOWED.GLUE LAMINATED TIMERSALL GLUE LAMINATED TIMBERS SHALL BE MANUFACTURED AND IDENTIFIED AS REQUIRED IN AITC A190 and ASTM D 3737. ALL GLUE LAMINATED TIMBERS SHALL BE DOUG-FIR LARCH, FABRICATED TO THE REQUIREMENTS OF THE US PRODUCT STANDARD PS 56. LUMBER SHALL BE OF SUCH GRADE TO PROVIDE NORMAL WORKING STRESS VALUES OF; 2,400 PSI IN BENDING, 1,100 PSI IN TENSION, 1,600 PSI IN COMPRESSION PARALLEL TO GRAIN, 560 PSI IN COMPRESSION PERPENDICULAR TO GRAIN AND 165 PSI HORIZONTAL SHEAR (COMBINATION 24F-V4). GLUE LAMINATED TIMBERS TO BE AITC CERTIFIED. USE WATERPROOF GLUE.CARPENTRYMANUFACTURED TRUSSESALL TRUSSES SHALL BE DESIGNED BY REGISTERED WA STATE ENGINEER AND FABRICATED FROM ONLY THESE DESIGNS. TRUSSES SHALL BE STAMPED BY THE ENGINEER OR BY A QUALITY CONTROL AGENCY SUCH AS THE STATE TRUSS FABRICATORS COUNCIL. ALL TRUSS DESIGNS SHALL BE SUBMITTED FOR APPROVAL PRIOR TO FABRICATION. ALL NON BEARING WALLS OR PARTITIONS SHALL BE HELD AWAY FROM THE TRUSS BOTTOM CHORD WITH AN APPROVED FASTENER TO ENSURE THAT THE TRUSS BOTTOM CHORD WILL NOT BEAR ON THE WALL OR PARTITION. APPROVED HANGERS SHALL BE USED AT ALL CONNECTIONS OF RAFTERS, JACK OR HIP TRUSSES TO MAIN GIRDER TRUSSES. ALL ROOF TRUSSES SHALL BE FRAMED AND TIED INTO THE FRAME WORK AND SUPPORTING WALLS SO AS TO FORM AN INTEGRAL PART OF THE WHOLE STRUCTURE. ROOF TRUSSES SHALL HAVE JOINTS WELL FITTED AND SHALL HAVE ALL TENSION MEMBERS WELL TIGHTENED BEFORE ANY LOAD IS PLACED UPON THE TRUSS. DIAGONAL AND SWAY BRACING SHALL BE USED TO BRACE ALL TRUSSES.INSULATION & MOISTURE PROTECTIONGENERALUNLESS NOTED OTHERWISE, INSULATION SHALL CONFORM TO THE WASHINGTON STATE ENERGY CODES. INSULATION BAFFLES TO MAINTAIN 1" CLEAR SPACE ABOVE INSULATION. BAFFLES TO EXTEND 6" ABOVE BATT INSULATION & 12" ABOVE LOOSE FILL INSULATION. INSULATE BEHIND BATHTUBS, SHOWERS, PARTITIONS AND CORNERS. PROVIDE FACE STAPLED BATTS OR FRICTION FIT FACED BATTS. PROVIDE 4 MIL (0.004") POLYETHYLENE VAPOR BARRIER AT WALLS OR USE PVA PAINT WITH A DRY CUP PERM RATING OF ONE (MAX.). PROVIDE R-10 INSULATION UNDER ELECTRIC WATER HEATERS.INFILTRATION CONTROL1. EXTERIOR JOINTS AROUND WINDOWS AND DOOR FRAMES, OPENINGS BETWEEN WALLS AND FOUNDATIONS, BETWEEN WALLS AND ROOF AND BETWEEN WALL PANELS, OPENINGS AT PENETRATIONS OF UTILITY SERVICES THROUGH WALLS, FLOORS, AND ROOF, AND ALL OTHERS SUCH OPENINGS IN THE BUILDING ENVELOPE, INCLUDING ACCESS PANELS INTO UNHEATED SPACES, SHALL BE SEALED, CAULKED, GASKETED OR WEATHER-STRIPPED TO LIMIT AIR INFILTRATION.2. ALL EXTERIOR DOORS, OTHER THAN FIRE-RATED DOORS, SHALL BE DESIGNED TO LIMIT AIR INFILTRATION AROUND THEIR PERIMETER WHEN IN A CLOSED POSITION. DOORS BETWEEN RESIDENCE AND GARAGE ARE NOT CONSIDERED "FIRE-RATED" AND MUST MEET THE ABOVE REQUIREMENT.3. ALL EXTERIOR WINDOWS SHALL BE DESIGNED TO ADMIT AIR INFILTRATION INTO OR FROM THE BUILDING ENVELOPE WHICH SHALL BE SUBSTANTIATED BY TESTING TO STANDARD ASTM E 283.73. SITE BUILT AND MILLWORK SHOP MADE WOODEN SASH ARE EXEMPT FROM TESTING BUT SHALL BE WEATHER-STRIPPED, CAULKED AND MORE TIGHTLY FITTING.4. RECESSED LIGHT FIXTURES TO LIMIT AIR LEAKAGE PER W.S.E.C.PIPING FOR HOT WATER / STEAM SYSTEMS OF PIPING FOR CONTINUOUSLY CIRCULATING HOT WATER SERVICE IS REQUIRED TO BE INSULATED PER THE W.S.E.C. SERVICE WATER PIPING SHALL BE INSULATED TO A MINIMUM OF R-3.VAPOR BARRIERS / GROUND COVERSAN APPROVED VAPOR BARRIER SHALL BE PROPERLY INSTALLED IN ROOF DECKS, IN ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS, AND AT EXTERIOR WALLS. INSET STAPLED BATTS WITH A PERM RATING LESS THAN ONE MAY BE INSTALLED IF THE VAPOR BARRIER IS TO THE WARM SIDE, STAPLES SHALL BE PLACED NOT MORE THAN 8" O.C. AND GAPS BETWEEN THE FACING AND THE FRAMING SHALL NOT EXCEED 1/16" A GROUND COVER OF 6 MIL (0.006") BLACK POLYETHYLENE OR EQUIVALENT SHALL BE LAID OVER THE GROUND IN ALL CRAWL SPACES. THE GROUND COVER SHALL BE OVERLAPPED ONE FOOT AT EACH JOINT AND SHALL EXTEND TO THE FOUNDATION WALL. THE NET FREE VENTILATING AREA FOR ATTIC VENTILATION MAY BE 1/300 OF THE AREA OF THE VENTILATED SPACE PROVIDED THAT A VAPOR BARRIER HAVE A PERM RATING NOT EXCEEDING ONE IS INSTALLED ON THE WARM SIDE OF THE INSULATION.DOORS, WINDOWS AND SKYLIGHTSGENERALTHE REQUIRED EGRESS DOOR MAY HAVE A MAXIMUM 7 3/4" STEP FROM TOP OF THE THRESHOLD TO A MINIMUM 36" DEEP LANDING. OTHER EXTERIOR DOORS MAY HAVE A MAXIMUM (2) 7 3/4" STEPS TO A MIN.. 36" DEEP LANDING. ALL GLAZING SHALL MEET THE REQUIREMENTS OF THE W.S.E.C. TABLE 6-1 UNLESS NOTED OTHERWISE. ALL SKYLIGHTS AND SKYWALLS SHALL HAVE LAMINATED GLASS UNLESS NOTED OTHERWISE. ALL BEDROOM EMERGENCY EGRESS WINDOWS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET. MINIMUM NET CLEAR OPERABLE WIDTH OF 20" AND A MINIMUM NET CLEAR OPENING HEIGHT OF 24", MAXIMUM FINISHED SILL HEIGHT OF 44" ABOVE FLOOR. OPERABLE WINDOWS WITH A SILL OF MORE THAN 72" ABOVE FINISHED GRADE AND WITHOUT AN ADJACENT ROOF WITH MAX 4:12 SLOPE, TO BE A MINIMUM OF 24" ABOVE ADJACENT FINISHED FLOOR.SAFETY GLAZING LOCATIONS PER 2015 IRC SECTION R308.41. GLAZING IN ALL FIXED AND OPERABLE PANELS OF SWINGING, SLIDING AND BI-FOLD DOORS.2. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24 INCH ARC OF THE DOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE FLOOR OR WALKING SURFACE.3. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL THAT MEETS ALL OF THE FOLLOWING CONDITIONS:3.1. THE EXPOSED AREA OF AN INDIVIDUAL PANEL IS LARGER THAN 9 SQUARE FEET AND:3.2. THE EXPOSED BOTTOM EDGE OF THE GLAZING IS LESS THAN 18" ABOVE THE FLOOR AND:3.3. THE TOP EDGE OF THE GLAZING IS MORE THAN 36" ABOVE THE FLOOR AND:3.4. ONE OR MORE WALKING SURFACES ARE WITHIN 36" MEASURED HORIZONTALLY AND IN A STRAIGHT LINE, OF THE GLAZING.4. ALL GLAZING IN RAILINGS REGARDLESS OF AREA OR HEIGHT ABOVE A WALKING SURFACE. INCLUDED ARE STRUCTURAL BALUSTER PANELS AND NONSTRUCTURAL INFILL PANELS.5. GLAZING IN ENCLOSURES FOR OR WALLS FACING HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS, AND SHOWERS. WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHES MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE.6. GLAZING IN WALLS AND FENCES ADJACENT TO INDOOR AND OUTDOOR SWIMMING POOLS, HOT TUBS, AND SPAS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60" ABOVE A WALKING SURFACE AND WITHIN 60" MEASURED HORIZONTALLY AND IN A STRAIGHT LINE, OF THE WATER'S EDGE. THIS SHALL APPLY TO SINGLE GLAZING AND ALL PANES IN MULTIPLE GLAZING.7. GLAZING ADJACENT TO STAIRWAYS, LANDINGS AND RAMPS WITHIN 36" HORIZONTALLY OF A WALKING SURFACE WHEN THE EXPOSED SURFACE OF THE GLAZING IS LESS THAN 60" ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE.8. GLAZING ADJACENT TO THE STAIRWAYS WITHIN 60" HORIZONTALLY OF THE BOTTOM TREAD OF A STAIRWAY IN ANY DIRECTION WHEN THE EXPOSED SURFACE OF THE GLAZING IS LESS THAN 60" ABOVE THE NOSE OF THE TREAD.FOR EXCEPTIONS SEE IRC SECTION R308.4FIREPLACESALL MASONRY FIREPLACES AND CHIMNEYS SHALL BE CONSTRUCTED TO CONFORM TO ALL APPLICABLE PORTIONS OF THE 2015 IBC/IRC CODE. FLUE LINER MINIMUM, 5/8" FIRE CLAY (OR EQ.) PER IRC. FLUE AREA PER IRC. CHIMNEYS SHALL SUPPORT ONLY THEIR OWN WEIGHT UNLESS SPECIFICALLY DESIGNED TO SUPPORT ADDITIONAL LOADS. ALL FIREPLACES SHALL BE PROVIDED WITH TIGHTLY FITTING FLUE DAMPERS, OPERATED WITH A READILY ACCESSIBLE MANUAL OR APPROVED AUTOMATIC CONTROL, AND AN OUTSIDE SOURCE OF COMBUSTION AIR. MINIMUM DUCT SIZE OF 6" SQ. INCHES IN AREA PROVIDED WITH READILY ACCESSIBLE DAMPER LOCATED IN FRONT PART OF FIREBOX. PRE-FABRICATED FIREPLACES, CHIMNEYS, AND RELATED COMPONENTS TO BEAR U.L. OR I.C.B.O. SEAL OR APPROVAL AND TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. HEARTHS SHALL EXTEND 20" (MIN.) IN FRONT OF AND 12" (MIN.) BEYOND EACH SIDE OF FIREPLACE OPENINGS WHEN REQ'D. FIREPLACES SHALL BE PROVIDED WITH TIGHTLY FITTING GLASS OR METAL DOORS.MECHANICALGENERALSOLID FUEL BURNING APPLIANCES INCLUDE AIRTIGHT STOVES, FIREPLACE STOVES, ROOM BEATERS, FACTORY BUILT FIREPLACES AND FIREPLACE INSERTS. ALL SOLID FUEL BURNING APPLIANCES SHALL COMPLY WITH THE PROVISIONS OF CHAPTER 24 OF THE 2012 INTERNATIONAL RESIDENTIAL CODE.HEATINGEACH DWELLING UNIT SHALL BE PROVIDED WITH HEATING FACILITIES CAPABLE OF MAINTAINING A TEMPERATURE OF 68 DEGREES FAHRENHEIT AT A HEIGHT OF 3'-0" ABOVE THE FLOOR AND TWO FEET FROM EXTERIOR WALLS IN ALL HABITABLE ROOMS WHEN THE OUTSIDE TEMPERATURE IS AS SET FORTH IN THE W.S.E.C. DEFINITION OF BUILDING THERMAL ENVELOPE FROM THE WASHINGTON STATE ENERGY CODE: THE BELOW-GRADE WALLS, ABOVE-GRADE WALLS, FLOOR, ROOF, AND ANY OTHER BUILDING ELEMENTS THAT ENCLOSE CONDITIONED SPACE OR PROVIDES A BOUNDARY BETWEEN CONDITIONED SPACE AND EXEMPT OR UNCONDITIONED SPACE. 1. FUEL BURNING APPLIANCES LOCATED WITHIN THE BUILDING ENVELOPE SHALL OBTAIN AIR FROM OUTDOORS, MEETING THE PROVISIONS OF CHAPTER 24 OF THE 2015 IRC. 2. FUEL BURNING APPLIANCES LOCATED OUTSIDE THE BUILDING ENVELOPE SHALL MEET THE PROVISIONS OF CHAPTER 24 OF THE 2015 IRC. 3. DUCTWORK LOCATION AND SOURCE OF COMBUSTION AIR SHALL MEET THE PROVISIONS OF CHAPTER 16 OF THE 2015 IRC. ALL WARM AIR FURNACES SHALL BE LISTED AND LABELED BY AN APPROVED AGENCY AND INSTALLED PER CHAPTER MI402 OF THE 2015 IRC. NO WARM AIR FURNACE SHALL BE INSTALLED IN A ROOM USED OR DESIGNED TO BE USED AS A BEDROOM, BATHROOM, CLOSET OR IN ANY ENCLOSED SPACE WITH ACCESS ONLY THROUGH SUCH ROOM OR SPACE, EXCEPT DIRECT VENT FURNACE, ENCLOSED FURNACES AND ELECTRIC HEATING FURNACES. NO WARM AIR FURNACE SHALL BE INSTALLED IN A CLOSET OR ALCOVE WITH A SPACE LESS THAN 12" WIDER THAN THE FURNACE OR A CLEARANCE OF 3" ALONG THE SIDES, BACK AND TOP. LIQUEFIED PETROLEUM GAS BURNING APPLIANCES SHALL NOT BE INSTALLED IN A PIT, BASEMENT OR SIMILAR LOCATION WHERE HEAVIER THAN AIR GASES MIGHT COLLECT. APPLIANCES SO FUELED SHALL NOT BE INSTALLED IN AN ABOVE GRADE UNDER FLOOR SPACE OR BASEMENT UNLESS SUCH LOCATION IS PROVIDED WITH AN APPROVED MEANS FOR REMOVAL OF UNBURNED GAS. HEATING AND COOLING APPLIANCES LOCATED IN A GARAGE AND WHICH GENERATE A GLOW, SPARK OR FLAME CAPABLE OF IGNITING FLAMMABLE VAPORS SHALL BE INSTALLED WITH THE PILOTS AND BURNERS OR HEATING ELEMENTS AND SWITCHES AT LEAST 18" ABOVE THE FLOOR SURFACE. FIRE DAMPERS NEED NOT BE INSTALLED IN AIR DUCTS PASSING THROUGH THE WALL, FLOOR OR CEILING SEPARATING A RESIDENCE (GROUP B, DIVISION 3 OCCUPANCY) FROM A GARAGE (GROUP M, DIVISION 1 OCCUPANCY), PROVIDED SUCH DUCTS WITHIN THE GARAGE ARE CONSTRUCTED OF STEEL HAVING A THICKNESS NOT LESS THAN 0.019" (NO. 26 GALVANIZED SHEET GAUGE) AND HAVE NO OPENINGS INTO THE GARAGE WARM AIR FURNACE INSTALLATIONS IN ATTICS OR CRAWL SPACES SHALL COMPLY WITH M1402 OF THE 2015 IRC. EVERY APPLIANCE DESIGNED TO BE VENTED SHALL BE CONNECTED TO A VENTING SYSTEM COMPLYING WITH CHAPTER 18 OF THE 2015 IRC. EVERY FACTORY BUILT CHIMNEY, TYPE L VENT, TYPE B GAS VENT OR TYPE BW GAS VENT SHALL BE INSTALLED IN ACCORDANCE WITH THE TERMS OF ITS LISTING, MANUFACTURERS INSTALLATION INSTRUCTIONS AND THE REQUIREMENTS PER CHAPTER 10 OF THE 2015 IRC. A TYPE B OR BW GAS VENT SHALL TERMINATE PER CHAPTER 24 OF THE 2015 IRC. VENT CONNECTORS SHALL BE INSTALLED WITHIN THE SPACE OR AREA IN WHICH THE APPLIANCE IS LOCATED AND SHALL BE CONNECTED TO A CHIMNEY OR VENT IN SUCH A MANNER AS TO MAINTAIN THE CLEARANCE TO COMBUSTIBLES PER SECTION M1803 OF THE 2015 IRC.HEATING EQUIPMENTALL HEATING EQUIPMENT SHALL COMPLY WITH SECTION M1401 OF THE 2015 IRC. FOR GAS AND OIL FIRED EQUIPMENT, OUTPUT MAY HAVE CAPACITY OF 150%-250% OF HEATING DESIGN LOAD PROVIDED THAT IT HAS AN AFUE OF 90% OR GREATERDUCTWORK1. DUCT SYSTEMS OR FACTORY BUILT AIR DUCTS SHALL BE OF METAL AS SET FORTH BY TABLE 1601.1.1 (1) & 1601.1.1 (2) 2. RECTANGULAR, FLAT, OVAL AND ROUND DUCT JOINTS AND SEAMS SHALL BE AIRTIGHT PER SECTION M1601.3.1 OF 3. INSTALLATION OF DUCTS SHALL COMPLY WITH SECTION M1601.3 OF THE 2015 IRC. 4. DUCT INSULATION SHALL BE INSTALLED IN ACCORDANCE WITH SECTION M1601.2.1 OF THE 2015 IRC.WHOLE HOUSE VENTILATIONSPECIFICATIONS FROM THE 2012 IRC SECTIONS M1507SOURCE SPECIFIC VENTILATION REQUIREMENTS. 1. MINIMUM EXHAUST FAN REQUIREMENTS: A.BATHROOMS, LAUNDRIES AND POWDER ROOMS - 50 CFM @ 0.25" W.G. B.KITCHENS - 100 CFM @ 0.25" W.G. (RANGE HOOD OR DOWN DRAFT EXHAUST FAN RATED AT MIN.. 100 CFM @ 0.10" W.G. MAY BE USED FOR EXHAUST FAN REQUIREMENTS.) 2. EXHAUST DUCT REQUIREMENTS:A.INSULATE TO R-8 (MIN..) IN UNCONDITIONED SPACES. B.EQUIP WITH A BACK DRAFT DAMPER. C.TERMINATE OUTSIDE THE BUILDING. D.COMPLY WITH TABLE 403.8.4.2 ON THIS SHEET. PRESCRIPTIVE REQUIREMENTS FOR: OPTION 1. INTERMITTENT WHOLE HOUSE VENTILATION USING EXHAUST FANS (IRC M1507.3.3(1). OUTDOOR AIR SHALL BE SUPPLIED TO ALL HABITABLE ROOMS AT FLOW RATES SPECIFIED IN TABLE M1507.3.3(1) ON THIS SHEET, USING THE FOLLOWING METHODS: 1. ROOM OUTDOOR AIR INLETS SHALL COMPLY WITH THE FOLLOWING: A.HAVE CONTROLLABLE AND SECURE OPENINGS. B.BE SLEEVED OR DESIGNED SO AS TO NOT COMPROMISE THE THERMAL PROPERTIES OF THE WALL OR WINDOW IN WHICH THEY ARE PLACED. C.PROVIDE A MINIMUM OF FOUR SQUARE INCHES OF NET FREE AREA OF OPENING FOR EACH HABITABLE SPACE. D.PROVISIONS SHALL BE MADE TO ENSURE AIR FLOW BY THE INSTALLATION OF DISTRIBUTION DUCTS, TRANSOMS, 1 INSTALLATION OF GRILLES, UNDERCUTTING DOORS A MINIMUM OF " ABOVE THE FINISHED FLOOR COVERINGS, OR 2 SIMILAR MEANS. 2. WHOLE HOUSE EXHAUST FANS SHALL: A.BE SIZED ACCORDING TO TABLE M1507.3.3(1) ON THIS SHEET. B.BE FLOW RATED AT 0.25" W.G. C.SOUND RATED AT 1.0 SONES MAXIMUM. 3. WHOLE HOUSE EXHAUST FAN CONTROLS: A.BE CONTROLLED BY A 24-HOUR CLOCK TIMER. B.PROVIDE CAPABILITY OF CONTINUOUS OPERATION, MANUAL AND AUTOMATIC CONTROL. C.THE 24-HOUR CLOCK TIMER SHALL BE READILY ACCESSIBLE. D.AT THE TIME OF FINAL INSPECTION, THE AUTOMATIC CONTROL TIMER SHALL BE SET TO OPERATE THE WHOLE HOUSE FAN FOR AT LEAST 8 HOURS A DAY. E.A LABEL SHALL BE AFFIXED TO THE CONTROL THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)". 4. WHOLE HOUSE EXHAUST DUCTS: A.BE SIZED ACCORDING TO TABLE 403.8.4.2 ON THIS SHEET. B.BE INSULATED TO A MINIMUM R-4 IN UNCONDITIONED SPACES. C.TERMINATE OUTSIDE THE BUILDING.FAN TESTED CFM @ 0.25" W.G.MINIMUM FLEX DIAMETERMAXIMUM LENGTH FEETMINIMUM SMOOTH DIAMETERMAXIMUM LENGTH FEETMAXIMUM ELBOWS5050508080801001001251254 INCH5 INCH6 INCH4 INCH5 INCH6 INCH5 INCH6 INCH6 INCH7 INCH4 INCH5 INCH6 INCH4 INCH5 INCH6 INCH5 INCH6 INCH6 INCH7 INCH25' - 0"25' - 0"NO LIMITN / A25' - 0"25' - 0"N / A25' - 0"25' - 0"25' - 0"25' - 0"25' - 0"NO LIMITN / A25' - 0"25' - 0"N / A25' - 0"25' - 0"25' - 0"3333333333*2*21. FOR EACH ADDITIONAL ELBOW, SUBTRACT 10'-0" FROM LENGTH. 2. FLEX DUCTS OF THIS DIAMETER ARE NOT PERMITTED WITH FANS OF THIS SIZE.IMC TABLE M403.8.4.2PRESCRIPTIVE EXHAUST DUCT SIZINGNUMBER OF BEDROOMS0 - 1 2 - 3 4 - 5 6 - 7 >7AIRFLOW IN CFM30<15001501 - 30003001 - 45004501 - 60006001 - 7500>75004560759010545607590105120607590105120135FLOOR AREA (SQ. FT.)7590105120135150901051201351501651. VENTILATION RATES IN TABLE ARE MINIMUM OUTDOOR AIRFLOW RATES MEASURED IN CFM.IRC TABLE M1507.3.3(1)MINIMUM VENTILATION RATES (CONTINUOUSLY OPERATING SYSTEMS)ENERGY CODETABLE R301.1CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE AND COUNTYKey: A - Moist, B - Dry, C - Marine. Absence of moisture designation indicates moisture regime is irrelevant.WASHINGTON5B Adams5B Asotin5B Benton5B Chelan4C Clallam4C Clark5B Comumbia4C Cowlitz5B Douglas6B Ferry5B Franklin5B Garfield5B Grant4C Grays Harbor4C Island4C Jefferson4C King4C Kitsap5B Kittitas5B Klickitat4C Lewis5B Lincoln4C Mason6B Okanogan4C Pacific6B Pend Oreille4C Pierce4C San Juan4C Skagit5B Skamania4C Snohomish5B Spokane6B Stevens4C Thurston4C Wahkiakum5B Walla Walla4C Whatcom5B Whitman5B YakimaTABLE R402.1.1INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTCLIMATE ZONEFENESTRATION U-FACTORSKYLIGHT U-FACTORGLAZED FENESTRATION SHGCCEILING R-VALUEWOOD FRAME WALL R-VALUEMASS WALL R-VALUEFLOOR R-VALUEBELOW-GRADE WALL R-VALUESLAB R-VALUE & DEPTH5 AND MARINE 40.300.50NR4921 int21/213010/15/21 int + TB10, 2ft60.300.50NR4921 + 5ci21+53010/15/21 + TB10, 4ftFOR SI: 1 FOOT .= 304.8 MM, CI .= CONTINUOUS INSULATION, INT .= INTERMEDIATE FRAMING. a. R-VALUES ARE MINIMUMS. U-FACTORS AND SHGC ARE MAXIMUMS. WHEN INSULATION IS INSTALLED IN A CAVITY WHICH IS LESS THAN THE LABEL OR DESIGN THICKNESS OF THE INSULATION, THE COMPRESSED R-VALUE OF THE INSULATION FROM APPENDIX TABLE A101.4 SHALL NOT BE LESS THAN THE R-VALUE SPECIFIED IN THE TABLE. b. THE FENESTRATION U-FACTOR COLUMN EXCLUDES SKYLIGHTS. THE SHGC COLUMN APPLIES TO ALL GLAZED FENESTRATION. EXCEPTION: SKYLIGHTS MAY BE EXCLUDED FROM GLAZED FENESTRATION SHGC REQUIREMENTS IN CLIMATE ZONES 1 THROUGH 3 WHERE THE SHGC FOR SUCH SKYLIGHTS DOES NOT EXCEED 0.30. c. "10/15/21.+TB" MEANS R-10 CONTINUOUS INSULATION ON THE EXTERIOR OF THE WALL, OR R-15 CONTINUOUS INSULATION ON THE INTERIOR OF THE WALL, OR R-21 CAVITY INSULATION PLUS A THERMAL BREAK BETWEEN THE SLAB AND THE BASEMENT WALL AT THE INTERIOR OF THE BASEMENT WALL. "10/15/21.+TB" SHALL BE PERMITTED TO BE MET WITH R-13 CAVITY INSULATION ON THE INTERIOR OF THE BASEMENT WALL PLUS R-5 CONTINUOUS INSULATION ON THE INTERIOR OR EXTERIOR OF THE WALL. "TB" MEANS THERMAL BREAK BETWEEN FLOOR SLAB AND BASEMENT WALL. d. R-10 CONTINUOUS INSULATION IS REQUIRED UNDER HEATED SLAB ON GRADE FLOORS. SEE R402.2.9.1. e. THERE ARE NO SHGC REQUIREMENTS IN THE MARINE ZONE. f. RESERVED. g. RESERVED. h. RESERVED.i. THE SECOND R-VALUE APPLIES WHEN MORE THAN HALF THE INSULATION IS ON THE INTERIOR OF THE MASS WALL. j. RESERVEDk. FOR SINGLE RAFTER- OR JOIST-VAULTED CEILINGS, THE INSULATION MAY BE REDUCED TO R-38. l. RESERVEDm.INT. (INTERMEDIATE FRAMING) DENOTES STANDARD FRAMING 16 INCHES ON CENTER WITH HEADERS INSULATED WITH A MINIMUM OF R-10 INSULATION. n. LOG AND SOLID TIMBER WALLS WITH A MINIMUM AVERAGE THICKNESS OF 3.5 INCHES ARE EXEMPT FROM THIS INSULATION REQUIREMENT.bbb,ejg,k,lic,kdhghgaWINTER DESIGN TEMPICE BARRIER UNDER-LAYMENT REQUIREDFLOOD HAZARDSAIR FREEZING INDEXMEAN ANNUAL TEMPVARIES110YES D1 or D2MODERATE12"SLIGHT TO MODERATE22° F NOVARIES100 or 250 50° FCLIMATIC AND GEOGRAPHIC DESIGN CRITERIAEQUIVALENT FLUID PRESSURE = 35 P.C.F. (UNRESTRAINED WALLS) 50 P.C.F. (RESTRAINED WALLS)Xproject:principal architectproject managerdrawn bychecked byjob no.datedaterevisions:byno.06/15/20202015 IRC CODEINFORMATIONA0.01SIECKE-TROWBRIDGEREMODEL16740 76th Ave WEdmonds, WA 98026CJCLDJGBCheckerSIECKE06/15/2020PERMIT SETRECEIVEDJun 16 2020CITY OF EDMONDSDEVELOPMENT SERVICESDEPARTMENT2015
UPUPUPUPUPA3.102A3.101A3.103STORAGEPOWDERROOMNEW POST & FOOTING, PER STRUCTURALPATCH LVT FLOORING AS REQ'D, MATCH EXISTINGA3.104(E) EXTERIOR COVERED DECK(E) POSTSVERIFY OR PROVIDE (3) 2x6, REFER TO STRUCTURALVERIFY EXTENT OF (E) CONCRETE SLABVERIFY NEW POST ABOVE LANDS ON FULL HEIGHT CONCRETE WALL, REFER TO STRUCTURALDEMO FLOORING & CONCRETE SLAB ON GRADE BELOW TO POUR NEW FOOTINGSTORAGE(E) EXTERIOR COVERED DECKproject:principal architectproject managerdrawn bychecked byjob no.datedaterevisions:byno.06/15/2020LOWER LEVEL DEMO& FLOOR PLANA2.00SIECKE-TROWBRIDGEREMODEL16740 76th Ave WEdmonds, WA 98026CJCLDJGBSIECKE06/15/2020PERMIT SETSCALE: 1/4" = 1'-0"1LOWER LEVEL PLAN (PROPOSED)SCALE: 1/4" = 1'-0"2LOWER LEVEL PLAN (DEMO)NN0 2' 4' 8'12'1' 3'0 2' 4' 8'12'1' 3'RECEIVEDJun 16 2020CITY OF EDMONDSDEVELOPMENT SERVICESDEPARTMENT
DNUPUPDNUPUPDININGROOMGARAGEDEMO GUARDRAILDEMO KITCHEN CABINETS & CTPSDEMO WALLDEMO WALLLIVINGROOMFOYERKITCHENDEMO & REROUTE EXISTING PLUMBING FROM WATER LINE @ FRIDGE TO NEW SINK @ ISLANDDEMO WINDOWS & DOOREXISTING HANDRAILS1A3.00A3.102A3.101DININGROOMGARAGENEW 6x6 POST PER STRUCTURAL(E) COLUMNEDGE OF DROPPED CEILING ABOVEOVENDW4'-0" 11'-3 1/8"NEW STEPREFACE EXISTING FIREPLACE, FURR OUT WALL (SEE A2.20)234571B1A10061C 1D1ECLERESTORY WINDOWS ABOVE; REFER TO ELEVATIONS8"8"4'-1 1/2"4'-1 3/8"A3.103NEW INFILL FRAMING BELOW WINDOWS, TYP.NEW INFILL FRAMING BELOW WINDOWS, TYP.NEW INFILL FRAMING BELOW WINDOWS, TYP.LIVINGROOMFOYERKITCHENMIN 100 CFM HOOD FANEQ EQCL9'-1 1/2"CLPLUMB FOR NEW SINKREPLACE EXISTING SINKREPLACE EXISTING GAS RANGEREFRIGNEW BEAM ABOVE11"A3.105A3.1045"10"4"2 3/4"5'-11 7/8"2 5/8"4"10"5 1/8"5 1/8"10"4 1/8"5 1/2"5'-11 7/8"6 5/8"3 3/8"10"5 5/8"6"2'-5" 4'-2" 2'-5"6"ALIGNALIGNNEW (3) 2x6 PER STRUCTURALNEW (3) 2x4 PER STRUCTURALDWNEW DWREPLACE EXISTING DWSDproject:principal architectproject managerdrawn bychecked byjob no.datedaterevisions:byno.06/15/2020MAIN LEVEL DEMO& FLOOR PLANA2.10SIECKE-TROWBRIDGEREMODEL16740 76th Ave WEdmonds, WA 98026CJCLDJGBSIECKE06/15/2020PERMIT SETLDSCALE: 1/4" = 1'-0"2MAIN LEVEL DEMO PLANSCALE: 1/4" = 1'-0"1MAIN LEVEL PLAN0 2' 4' 8'12'1' 3'0 2' 4' 8'12'1' 3'NNRECEIVEDJun 16 2020CITY OF EDMONDSDEVELOPMENT SERVICESDEPARTMENT
UPUPUPUP1A3.00A3.102A3.101A3.103FRAME PARTIAL-HEIGHT WALL/GUARDRAILLOFTA3.105A3.104(E) GWB LEDGE/ CLOSET CEILING TO REMAINOPEN TO LIVING ROOM BELOWOPEN TO DINING AREA BELOWNEW BEAM ABOVE6" 2'-5" 4" 3'-6" 4" 2'-5" 6"NEW BEAM, REFER TO STRUCTURALNEW 2x FRAMING1C1D1EDEMO WOOD GUARD RAILDEMO WALLDEMO CLERESTORY WINDOWSLOFTEXISTING HANDRAILSproject:principal architectproject managerdrawn bychecked byjob no.datedaterevisions:byno.06/15/2020UPPER LEVEL DEMO& FLOOR PLANA2.20SIECKE-TROWBRIDGEREMODEL16740 76th Ave WEdmonds, WA 98026CJCLDJGBSIECKE06/15/2020PERMIT SETAuthorSCALE: 1/4" = 1'-0"1UPPER LEVEL PLANSCALE: 1/4" = 1'-0"2UPPER LEVEL DEMO PLANNN0 2' 4' 8'12'1' 3'0 2' 4' 8'12'1' 3'RECEIVEDJun 16 2020CITY OF EDMONDSDEVELOPMENT SERVICESDEPARTMENT
MAIN LEVEL
100' -0"
ROOF
122' -5 171/256"
UPPER LEVEL
107' -6"
T.O. PLATE
114' -8 235/256"
A3.10
2
GARAGE
99' -0"2'-9" 3'-6" 2'-9"8'-0" 5" 3'-6"3'-9"3'-0"1C 1D 1E
1A 1B
2 3 4 5 6 7
NEW INFILL FRAMING BELOW
WINDOWS & NEW SIDING TO
MATCH EXISTING, TYP.
A3.10
4
2'-5" 4" 3'-6" 4" 2'-5"
4"
TT project:principal architect
project manager
drawn by
checked by
job no.
date
date
revisions:
b
y
no.
06/15/2020
EXTERIOR
ELEVATIONS &
SCHEDULES
A3.00SIECKE-TROWBRIDGEREMODEL16740 76th Ave WEdmonds, WA 98026CJC
LD
JGB
SIECKE
06/15/2020
PERMIT SET
CJC
SCALE: 1/4" = 1'-0"1 EAST ELEVATION
065_WINDOWS
MARK OPERATION MANUFACTURER MODEL
DIMENSIONS (ROUGH OPENING)
U VALUE UA VALUE REMARKSWIDTH HEIGHT AREA
1A FIXED TBD 2' - 5" 8' - 0" 19 SF 0.3 6 TEMPERED
1B FIXED TBD 2' - 5" 8' - 0" 19 SF 0.3 6 TEMPERED
1C FIXED TBD 2' - 5" 3' - 6" 8 SF 0.3 3
1D FIXED TBD 3' - 6" 3' - 6" 12 SF 0.3 4
1E FIXED TBD 2' - 5" 3' - 6" 8 SF 0.3 3
2 CASEMENT TBD 10" 3' - 9" 3 SF 0.3 1
3 FIXED TBD 6' - 0" 3' - 9" 22 SF 0.3 7
4 CASEMENT TBD 10" 3' - 9" 3 SF 0.3 1
5 CASEMENT TBD 10" 3' - 9" 3 SF 0.3 1
6 FIXED TBD 6' - 0" 3' - 9" 22 SF 0.3 7
7 CASEMENT TBD 10" 3' - 9" 3 SF 0.3 1
11 125 SF 38
055 & 056_DOORS
MARK LOCATION
DIMENSIONS
REMARKSWIDTH HEIGHT THICKNESS
MAIN LEVEL
100 FOYER 3' - 4" 8' - 0" 1 3/4" FRONT ENTRY
Grand total: 1
0 2' 4' 8'12'1' 3'
RECEIVED
Jun 16 2020
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
MAIN LEVEL
100' -0"
LOWER LEVEL
91' -9"
UPPER LEVEL
107' -6"
T.O. PLATE
114' -8 235/256"
NEW BEAM, REFER
TO STRUCTURAL
NEW
COLUMN
BEYOND
A3.10
1
GARAGE
99' -0"
LIVING ROOM
101' -0"1'-0"A3.10
3
(E) RAISED
FLOOR TO
REMAIN
(E) ATTIC SPACE
LIVING
ROOM
NEW FOOTING BEYOND,
REFER TO STRUCTURAL
NEW BEAM BEYOND,
REFER TO STRUCTURAL
NEW POST PER
STRUCTURAL
MAIN LEVEL
100' -0"
ROOF
122' -5 171/256"
LOWER LEVEL
91' -9"
UPPER LEVEL
107' -6"
T.O. PLATE
114' -8 235/256"
A3.10
2
GARAGE
99' -0"
LIVING ROOM
101' -0"
(E) STEP TO REMAIN
LOFT LEVEL
108' -8"
(E) ATTIC SPACE
KITCHEN FOYER
PONY WALL
BEYOND
NEW BEAM, REFER
TO STRUCTURAL
MAIN LEVEL
100' -0"
ROOF
122' -5 171/256"
LOWER LEVEL
91' -9"
UPPER LEVEL
107' -6"
T.O. PLATE
114' -8 235/256"
A3.10
2
GARAGE
99' -0"
LIVING ROOM
101' -0"
(E) RAISED FLOOR TO
REMAIN
NEW STEP
(E) GWB WALL
ABOVE (E) GWB WALL
ABOVE (E) WALL
NEW PARTIAL
WALL
6"6"NEW COLUMN
BEYOND
11 1/4"GUARDRAIL3'-0"LOFT LEVEL
108' -8"
NEW BEAM, REFER TO
STRUCTURAL
A3.10
4
LIVING
ROOM
DINING
ROOM
(E) COLUMN
A3.10
1
A3.10
3
EXISTING
COLUMN W/
GWB WRAP
EXTEND
FRAMING FOR
GUARDRAIL,
GWB WRAP
OPEN TO
BEYOND 3'-0"LIVING
ROOMFOYER
OPEN TO LOFT
BEYOND
FIREPLACE
MAIN LEVEL
100' -0"
ROOF
122' -5 171/256"
UPPER LEVEL
107' -6"
T.O. PLATE
114' -8 235/256"
A3.10
1
LIVING ROOM
101' -0"
A3.10
3
LOFT LEVEL
108' -8"3'-0"EXISTING
COLUMN W/
GWB WRAP
EXTEND FRAMING FOR
GUARDRAIL, GWB WRAP
OPEN TO
LIVING
ROOM
OPEN TO
FOYER
3'-0"3'-0"3'-0"(E) GWB WRAPPED BEAM
project:principal architect
project manager
drawn by
checked by
job no.
date
date
revisions:
b
y
no.
06/15/2020
BUILDING SECTIONS
& ELEVATIONS
A3.10SIECKE-TROWBRIDGEREMODEL16740 76th Ave WEdmonds, WA 98026CJC
LD
JGB
SIECKE
06/15/2020
PERMIT SET
SCALE: 1/4" = 1'-0"2 WEST-EAST SECTION
SCALE: 1/4" = 1'-0"1 NORTH-SOUTH SECTION A
SCALE: 1/4" = 1'-0"3 NORTH-SOUTH SECTION B
SCALE: 1/4" = 1'-0"5
LIVING ROOM -FOYER SOUTH
ELEVATION
SCALE: 1/4" = 1'-0"4 LOFT-STAIR SECTION
0 2' 4' 8'12'1' 3'0 2' 4' 8'12'1' 3'
0 2' 4' 8'12'1' 3'
0 2' 4' 8'12'1' 3'0 2' 4' 8'12'1' 3'
RECEIVED
Jun 16 2020
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
CRITERIADESIGN LOADING CRITERIASNOW LOADGEOTECHNICALALLOWABLE SOIL PRESSURELATERAL EARTH PRESSURE (RESTRAINED/UNRESTRAINED)COEFFICIENT OF FRICTION (FACTOR OF SAFETY OF 1.5 INCLUDED)CONCRETEFTGS & OTHER UNFORMED SURFACES CAST AGAINST & PERMANENTLY EXPOSED TO EARTH FORMED SURFACES EXPOSED TO EARTH OR WEATHER (#5 BARS OR SMALLER) COLUMN TIES OR SPIRALS AND BEAM STIRRUPS WOOD MINIMUM BASE VALUE, Fb = 850 PSIMINIMUM BASE VALUE, Fb = 1000 PSIMINIMUM BASE VALUE, Fb = 1350 PSIMINIMUM BASE VALUE, Fc = 1350 PSIMINIMUM BASE VALUE, Fc = 1000 PSIWOOD FASTENERS6d8d10d12d16d BOXDOUGLAS-FIR-LARCH OR HEM-FIR NO. 2Pf = 25 PSF3"1-1/2"1-1/2"FORMED SURFACES EXPOSED TO EARTH OR WEATHER (#6 BARS OR LARGER) 2"SLABS AND WALLS (INTERIOR FACE)GREATER OF BAR Ø PLUS 1/8" OR 3/4"WOOD (continued)1. 2. 3. 4. 5. 6. 7. 8. 9. 10.11.12.13.14.15.19.20.16.17.18.ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS,SPECIFICATIONS, AND THE 2012 INTERNATIONAL BUILDING CODE, AND THE 2012 SEATTLE BUILDING CODE.STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS FORBIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FORCOMPATIBILITY AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION.CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE & STRUCTURALCOMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THEPLANS.CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS & THE METHODS,TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE CONTRACTORS WORK.THE STRUCTURAL ENGINEER HAS NO OVERALL SUPERVISORY AUTHORITY OR ACTUAL AND/ORDIRECT RESPONSIBILITY FOR THE SPECIFIC WORKING CONDITIONS AT THE SITE AND/OR FOR ANYHAZARDS RESULTING FROM THE ACTIONS OF ANY TRADE CONTRACTOR. THE STRUCTURALENGINEER HAS NO DUTY TO INSPECT, SUPERVISE, NOTE, CORRECT, OR REPORT ANY HEALTH ORSAFETY DEFICIENCIES OF THE OWNER, CONTRACTORS, OR OTHER ENTITIES OR PERSONS AT THEPROJECT SITE.CONTRACTOR-INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT &STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGESSHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT.DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONSARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILARDETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THEARCHITECT AND THE STRUCTURAL ENGINEER.FOUNDATION NOTES: ALLOWABLE SOIL PRESSURE AND LATERAL EARTH PRESSURE ARE ASSUMED& THEREFORE MUST BE VERIFIED BY A QUALIFIED SOILS ENGINEER OR APPROVED BY THE BUILDINGOFFICIAL. IF SOILS ARE FOUND TO BE OTHER THAN ASSUMED, NOTIFY THE STRUCTURAL ENGINEERFOR POSSIBLE FOUNDATION REDESIGN.FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED EARTH AT LEAST 18" BELOW ADJACENT FINISHEDGRADE, UNLESS NOTED OTHERWISE, FOOTINGS SHALL BE CENTERED BELOW COLUMNS OR WALLSABOVE.BACK FILL BEHIND ALL RETAINING WALLS WITH FREE DRAINING, GRANULAR FILL AND PROVIDE FORSUBSURFACE DRAINAGE.CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN ACCORDANCE WITH IBCSECTION 1905, 1906 AND ACI 301, INCLUDING TESTING PROCEDURES. CONCRETE SHALL ATTAIN A 28-DAY STRENGTH OF f'c = 2,500 PSI AND MIX SHALL CONTAIN NOT LESS THAN 5-1/2 SACKS OF CEMENTPER CUBIC YARD AND SHALL BE PROPORTIONED TO PRODUCE A SLUMP OF 5" OR LESS.REINFORCING STEEL SHALL CONFORM TO ASTM A615 (INCLUDING SUPPLEMENT S1), GRADE 60,fy = 60,000 PSI. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185. SPIRAL REINFORCEMENTSHALL BE PLAIN WIRE CONFORMING TO ASTM 615, GRADE 60, fy = 60,000 PSI.REINFORCING STEEL SHALL BE DETAILED (INCLUDING HOOKS AND BENDS) IN ACCORDANCEWITH ACI 315-92 AND 318-14. LAP ALL CONTINUOUS REINFORCEMENT #5 AND SMALLER 40 BARDIAMETERS OR 2'-0" MINIMUM. PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTERSECTIONS.LAP CORNER BARS #5 AND SMALLER 40 BAR DIAMETERS OR 2'-0" MINIMUM. LAPS OF LARGERBARS SHALL BE MADE IN ACCORDANCE WITH ACI 318-14, CLASS B. LAP ADJACENT MATS OFWELDED WIRE FABRIC A MINIMUM OF 8" AT SIDES AND ENDS.NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESSSPECIFICALLY SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER.CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS:CAST-IN-PLACE CONCRETE: SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS & DIMENSIONSOF DOOR AND WINDOW OPENINGS IN ALL CONCRETE WALLS. SEE ARCHITECTURAL DRAWINGS FORALL GROOVES, NOTCHES, CHAMFERS, FEATURE STRIPS, COLOR, TEXTURE & OTHER FINISH DETAILSAT ALL EXPOSED CONCRETE SURFACES, BOTH CAST-IN-PLACE AND PRE-CASTFRAMING LUMBER SHALL BE KILN DRIED OR MC-19, & GRADED & MARKED IN CONFORMANCEWITH W.C.L.I.B. STANDARD GRADING RULES FOR WEST COAST LUMBER NO. 17. FURNISH TOTHE FOLLOWING MINIMUM STANDARDS:GLUED LAMINATED MEMBERS SHALL BE FABRICATED IN CONFORMANCE WITH ASTM AND AITCSTANDARDS. EACH MEMBER SHALL BEAR AN A.I.T.C. IDENTIFICATION MARK AND SHALL BEACCOMPANIED BY AN A.I.T.C. CERTIFICATE OF CONFORMANCE. ALL SIMPLE SPAN BEAMS SHALL BEDOUGLAS FIR COMBINATION 24F-V4, Fb = 2,400 PSI, Fv = 240 PSI. ALL CANTILEVERED BEAMS SHALL BEDOUGLAS FIR COMBINATION 24F-V8, Fb = 2,400 PSI, Fv = 240 PSI. CAMBER ALL SIMPLE SPAN GLULAMBEAMS TO 3,000' RADIUS, UNLESS SHOWN OTHERWISE ON THE PLANS.ALL WOOD IN DIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE-TREATEDWITH AN APPROVED PRESERVATIVE OR (2) LAYERS OF ASPHALT IMPREGNATED BUILDING PAPERSHALL BE PROVIDED BETWEEN UNTREATED WOOD AND CONCRETE OR MASONRY.PRESSURE TREATED WOOD SHALL BE TREATED WITH WATERBORNE PRESERVATIVES PER AWPASTANDARD U1. INTERIOR WOOD IN CONTINUOUS CONTACT WITH CONCRETE (SUCH AS SILL PLATES)SHALL BE IN ACCORDANCE WITH USE CATEGORY 2 (UC2).WOOD IN CONTINUOUS CONTACT WITHFRESH WATER OR SOIL SHALL BE IN ACCORDANCE WITH USE CATEGORY 3B (UC3B). TIMBERCONNECTORS IN DIRECT CONTACT WITH TREATED WOOD SHALL BE G185 OR A185 HOT DIPPED ORCONTINUOUS HOT GALVANIZED PER ASTM A653. FASTENERS AND TIMBER CONNECTORS IN DIRECTCONTACT WITH ACZA TREATED WOOD SHALL BE TYPE 304 OR 316 STAINLESS STEEL.NAIL SIZES SPECIFIED ON DRAWINGS ARE BASED ON THE FOLLOWING SPECIFICATIONS:ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THEHEADS AND NUTS OF ALL BOLTS AND LAG BOLTS BEARING ON WOOD. INSTALLATION OF LAGBOLTS SHALL CONFORM TO THE NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION(2015 EDITION) WITH A LEAD BORE HOLE OF 60-70% OF THE SHANK DIAMETER. LEAD HOLES ARENOT REQUIRED FOR 3/8"Ø AND SMALLER LAG SCREWS.B.WOOD FRAMING NOTES--THE FOLLOWING APPLY UNLESS OTHERWISE SHOWN ON THE PLANS:ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO THEMINIMUM STANDARDS OF THE INTERNATIONAL BUILDING CODE. MINIMUM NAILING, UNLESS NOTEDOTHERWISE, SHALL CONFORM TO TABLE 2304.10.1 OF THE INTERNATIONAL BUILDING CODE.COORDINATE THE SIZE & LOCATION OF ALL OPENINGS WITH MECHANICAL AND ARCHITECTURALDRAWINGS.FLOOR AND ROOF FRAMING: PROVIDE DOUBLE JOISTS UNDER ALL PARALLEL PARTITIONS THATEXTEND OVER MORE THAN HALF THE JOIST LENGTH & AROUND ALL OPENINGS IN FLOORS ORROOFS UNLESS NOTED OTHERWISE PROVIDE SOLID BLOCKING AT ALL BEARING POINTS. TOENAILJOISTS TO SUPPORTS WITH TWO 16d NAILS. ATTACH TIMBER JOISTS TO FLUSH HEADERS OR BEAMSWITH SIMPSON METAL JOIST HANGERS IN ACCORDANCE WITH NOTES ABOVE. NAIL ALL MULTI-JOISTBEAMS TOGETHER WITH TWO ROWS 16d @ 12"OC UNLESS NOTED OTHERWISE ON THE PLANS,PLYWOOD ROOF AND FLOOR SHEATHING SHALL BE LAID UP WITH GRAIN PERPENDICULAR TOSUPPORTS AND NAILED AT 6"OC WITH 8d NAILS TO FRAMED PANEL EDGES, STRUTS & OVER STUDWALLS AS SHOWN ON PLANS AND @ 12"OC TO INTERMEDIATE SUPPORTS. PROVIDE APPROVEDPLYWOOD EDGE CLIPS CENTERED BETWEEN JOISTS/TRUSSES AT UNBLOCKED ROOF SHEATHINGEDGES. ALL FLOOR SHEATHING EDGES SHALL HAVE APPROVED T&G JOINTS OR SHALL BESUPPORTED WITH SOLID BLOCKING. ALLOW 1/8" SPACING AT ALL PANEL EDGES AND ENDS OFFLOOR & ROOF SHEATHING. TOENAIL BLOCKING TO SUPPORTS WITH 16d @ 12"OC, UNLESS NOTEDOTHERWISE.ALL WALLS SHALL HAVE A SINGLE BOTTOM PLATE & A DOUBLE TOP PLATE. END NAIL TOP PLATE TOEACH STUD WITH TWO 16d NAILS, & TOENAIL OR END NAIL EACH STUD TO BOTTOM PLATE WITHTWO 16d NAILS. FACE NAIL DOUBLE TOP PLATE WITH 10d @ 12"OC & LAP MINIMUM 4'-0" AT JOINTSAND PROVIDE TWELVE 10d NAILS @ 4"OC EACH SIDE JOINT.WALL FRAMING: REFER TO ARCHITECTURAL DRAWINGS FOR THE SIZE OF ALL WALLS. ALL STUDSSHALL BE SPACED AT 16" OC, UNLESS NOTED OTHERWISE TWO STUDS, MINIMUM, SHALL BEPROVIDED AT THE END OF ALL WALLS & AT EACH SIDE OF ALL OPENINGS, & AT BEAM OR HEADERBEARING LOCATIONS. TWO 2x8 HEADERS SHALL BE PROVIDED OVER ALL OPENINGS NOTOTHERWISE NOTED. SOLID BLOCKING FOR WOOD COLUMNS SHALL BE PROVIDED THROUGHFLOORS TO SUPPORTS BELOW. PROVIDE CONTINUOUS SOLID BLOCKING AT MID-HEIGHT OF ALLSTUD WALLS OVER 10'-0" IN HEIGHT.ALL STUD WALLS SHALL HAVE THEIR LOWER WOOD PLATES ATTACHED TO WOOD FRAMING BELOWWITH 16d NAILS @ 6"OC, OR ATTACHED TO CONCRETE BELOW WITH 5/8"Ø ANCHOR BOLTS @ 4'-0"OC,EMBEDDED 7" MINIMUM, UNLESS NOTED OTHERWISE. INDIVIDUAL MEMBERS OF BUILT-UP POSTSSHALL BE NAILED TO EACH OTHER WITH TWO ROWS OF 16d @ 12"OC. UNLESS NOTED OTHERWISE,GYPSUM WALLBOARD SHALL BE FASTENED TO THE INTERIOR SURFACE OF ALL STUDS & PLATESWITH NO. 6 X 1-1/4" TYPE S OR W SCREWS @ 8"OC. UNLESS NOTED OTHERWISE, 1/2" (NOMINAL) APARATED SHEATHING (SPAN RATING 24/0) SHALL BE NAILED TO ALL EXTERIOR VERTICAL SURFACESWITH 8d NAILS @ 6"OC AT PANEL EDGES & TOP & BOTTOM PLATES (BLOCK UNSUPPORTED EDGES)& TO ALL INTERMEDIATE STUDS & BLOCKING WITH 8d NAILS @ 12"OC. ALLOW 1/8" SPACING AT ALLPANEL EDGES & PANEL ENDS.BEARING WALL BELOWBEARING WALL ABOVENON-BEARING WALL BELOWHANGERMETAL CONNECTORCOLUMN BELOWSHEARWALL TYPE & LENGTHJOIST or RAFTER SPANJOIST or RAFTER EXTENTSBEAM or HEADERFOOTING (BELOW GRADE)LOW ROOF FRAMINGHORIZ STRAPPING HARDWAREVERTICAL HOLDOWN STRAPFOOTING TYPE-SECTION3SECTION NUMBERDRAWING WHERESECTION IS LOCATEDDETAIL NUMBERDRAWING WHEREDETAIL IS LOCATEDSECTION NUMBERDRAWING WHERESECTION TAKEN FROMCONCRETE ON PLANLEGENDSSWX (X'-X")IF CONTRACTOR PROPOSES THE USE OF ALTERNATE NAILS, THEY SHALL SUBMIT NAILSPECIFICATIONS TO THE STRUCTURAL ENGINEER (PRIOR TO CONSTRUCTION) FOR REVIEW ANDAPPROVAL. PLYWOOD (APA RATED SHEATHING) FASTENERS TO FRAMING SHALL BE DRIVEN FLUSHTO FACE OF SHEATHING WITH NO COUNTERSINKING PERMITTED.TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG-TIE" BY SIMPSONCOMPANY, AS SPECIFIED IN THEIR CATALOG NUMBER C-C-2015. EQUIVALENT DEVICES BY OTHERMANUFACTURERS MAY BE SUBSTITUTED, PROVIDED THEY HAVE ICBO OR ICC-ES APPROVAL FOREQUAL OR GREATER LOAD CAPACITIES. PROVIDE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BYMANUFACTURER. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERSRECOMMENDATIONS.ALL 2X JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "LUS" SERIES JOIST HANGERS.ALL TJI JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "ITS" SERIES JOIST HANGERS.ALL DOUBLE JOIST BEAMS SHALL BE CONNECTED TO FLUSH BEAMS WITH "MIT" SERIES JOIST HANGERS.WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS OR BOLTSIN EACH MEMBER. ALL SHIMS SHALL BE SEASONED AND DRIED AND THE SAME GRADE (MINIMUM) ASMEMBERS CONNECTED.0.113"0.131"0.148"0.148"0.135"2" 2-1/2" 3" 3-1/4" 3-1/2" A.A.B.1500 PSF55 PCF/35 PCF 0.3GENERAL STRUCTURAL NOTES(The following apply unless shown otherwise on the plans)SIZE LENGTH DIAMETERHEM-FIR NO. 2DOUGLAS FIR-LARCH NO. 1DOUGLAS FIR-LARCH NO. 1DOUGLAS FIR-LARCH NO. 2DOUGLAS FIR-LARCH NO. 1(2x & 3x MEMBERS) (4x MEMBERS) (INCL. 6x AND LARGER) (4x MEMBERS) (6x AND LARGER) JOISTS AND BEAMS: LARGE BEAMS: POSTS: STUDS, PLATES & MISC. FRAMINGABBREVIATIONS1S4.0F11S4.0ROOF DECK EXTENT ON PLANAND&AT@ABALTAPPROXARCHANCHOR BOLTAPPROXIMATE(LY)ALTERNATE(LY)ARCHITECT(URAL)BUILT UPBOTTOMBOTBUCCC/WCOLUMNCONCRETECONCCOLCJLCCL,CENTER LINECOMPLETE WITHCENTER TO CENTERCONSTRUCTION JOINTCENTERCTRCONTCONSTDETAILDIMENSIONDIMDETDOWNDITTODODNEACHDRAWINGSEADWGSDEEPDPDLDEAD LOADCONSTRUCTIONCONTINUOUS ELEVATIONEQ SPELEXISTINGFD(E)EWEACH WAYFIN FLFIN GRFLOORFAR SIDEGAUGEGAF/SFLFDNFOUNDATIONEQUAL(LY) SPACES(D)FLOOR DRAINFINISHED,FINAL GRADEFINISHED FLOORGALVANIZEDGLGALVLONGLGLIGHTLTLLLIVE LOADHORIZHORIZONTALGRIDLINE, BAYLINEEFEACH FACEBLOCKINGBLKGMINIMUMMINMFRON CENTEROCNTSN/SNEAR SIDEOPENINGOPPOSITEOWSJOPPOOPNGPLATELPPL,PERPMANUFACTURERNOT TO SCALEOPEN WEB STEEL JOISTPERPENDICULARREINFREVISIONR/WREVREQUIREDREQ'DSIMILARSIMSPECSPSOGSECTIONSECTREINFORCEMENTREINFORCED WITHSPACE(D)(S)(ING)SPECIFICATION SLAB ON GRADERADIUSRSTEELSTRSTLTHKT&BTOSTOCTYPICALTYPSTRUCTURE(AL)TOP AND BOTTOMTOP OF CONCRETETOP OF STRUCTURAL STEELTHICK(NESS)UNDERSIDEUNOU/SWIDEVERTICALWVERTWITHW/UNLESS NOTED OTHERWISESTIR(S)STIRRUP(S)SWSHEAR WALLHDRHEADERFOOTINGFTGGTGIRDER TRUSST>OUNGE AND GROOVEBETWEENBETW'NBUILDINGBLDGMAXIMUMMAXNNEWH, HTHEIGHTBACKSPANBSEXTERIOREXTGLBGLULAM BEAMINTRINTERIORMATERIALMATLPRESSURE TREATEDPTINTINTERSECTIONBEAMBMFLUSH BEAMFBKPKING POSTSTAGSTAGGEREDHGR(S)HANGER(S)INVINVERTEDFRAMINGFRMGSTDSTANDARDDRAGTRUSSDTDRAG STRUTDSAPreliminarySheet No.Sheet ContentsJob No.No.DateIssuenickerson engineering2221 Everett Ave #202Everett, WA 98201425.610.4425SIECKE-TROWBRIDGE REMODEL
16740 76TH AVE W
EDMONDS, WA 98026 c Nickerson Engineering, LLC 2020 Thesedrawings were prepared for the"SIECKE-TROWBRIDGE REMODEL" project in EDMONDS, WA. They are notintended for use on any other project.Stated drawing scale is based on36" x 24" sheet.006.08.20Permit05.29.20GENERAL NOTES20-033S1.0RECEIVEDJun 16 2020CITY OF EDMONDSDEVELOPMENT SERVICESDEPARTMENT
(E) COL(E) COLVERIFY ORPROVIDE (3) 2x6(N) 6x6 FULL HT(N) 6x6FULL HTw/ ECCQ46(N) (3) 2x6 W/ H6 ORLSTA18 EACH SIDEOF BEAM TO POST(E) CEILING FRAMING(E) RAFTERS(E) COL(E) CEILING FRAMING(E) RAFTERS(E) DROPPED BEAMSCALE: 1/4" = 1'-0"ROOF FRAMING PLANSCALE: 1/4" = 1'-0"MAIN FLOOR FRAMING PLANPLAN NOTES1.DO NOT SCALE DRAWINGS. REFER TO ARCH DWGS FOR ALL DIMENSIONS.2.PROVIDE FULL DEPTH VERTICAL GRAIN BLOCKING TO MATCH AND ALIGNWITH POST ABOVE IN FLOOR FRAMING.3.REFER TO GENERAL STRUCTURAL NOTES FOR ADDITIONAL REQUIREMENTS.(N) 312x12 GLB (DROPPED)(N) 312x12 GLB2S3.03S3.0HUCQ4121S3.0F2.5FOOTING SCHEDULEMARKSIZEREINFORCEMENT2'-6" x 2'-6" x 10" DP(3)#4 EW 3" FROM BOTF2.5NEW FTGBELOW4S3.0CONTRACTOR TO FIELD VERIFY NEWPOST ABOVE LANDS ON EX. FULLHEIGHT CONCRETE WALL.CONTACT ENGINEER OF RECORD IFFOUND OTHERWISE.(N) (3) 2x4 W/ H6 ORLSTA18 EACH SIDEOF BEAM TO POST1/4"=1'-0"4'08'16'FRAMING PLAN20-033S2.0APreliminarySheet No.Sheet ContentsJob No.No.DateIssuenickerson engineering2221 Everett Ave #202Everett, WA 98201425.610.4425SIECKE-TROWBRIDGE REMODEL
16740 76TH AVE W
EDMONDS, WA 98026 c Nickerson Engineering, LLC 2020 Thesedrawings were prepared for the"SIECKE-TROWBRIDGE REMODEL" project in EDMONDS, WA. They are notintended for use on any other project.Stated drawing scale is based on36" x 24" sheet.006.08.20Permit05.29.20RECEIVEDJun 16 2020CITY OF EDMONDSDEVELOPMENT SERVICESDEPARTMENT
S3.0SCALE: 3/4" = 1'-0"4NEW PAD @ SLAB ON GRADEEX. SLAB ONGRADEEX. FLOOR FRAMINGAND SHEATHINGEX. ROOF RAFTERSAND SHEATHINGEX. WALL AND TOPPLATE TO BE REMOVEDVERIFY OR PROVIDE 2xBLOCKING EACH BAYNEW BEAM PER PLANNEW BEAM PER PLAN2x4 @ 16" OC PONYWALL TO ROOF16d @ 6" OCEX. ROOF RAFTERSAND SHEATHINGEX. CEILING FRAMING W/LUS SERIES HANGEREX. ROOF RAFTERSAND SHEATHING2x BLOCKINGEACH BAYNEW BEAM PER PLANPOST CAP PER PLANPOST PER PLAN(REFER TO DETAIL4/S3.0 FOR POST @FLOOR FRAMING)PONY WALL TO ROOFNEW BEAM PER PLAN(CENTER ON NEW POSTPER PLAN)EX. CEILING FRAMINGHANGER PER PLANPOST PER PLANEX. FLOORSHEATHINGPOST PER PLAN EX. FLOOR FRAMING NOTSHOWN FOR CLARITYEX. CONCRETESTEM WALLEX. SLAB ON GRADEEX. CRAWLSPACE1H1VBOTTOM OF NEW PAD TO BE ATOR BELOW 1:1 INFLUENCE LINENEW PAD PER PLAN W/REINFORCEMENT PER PLAN10" SQ PLINTH - REINFw/ (4)#4 x VERT& #3 x @ 6" OCABA SERIES POSTBASE W/ 58" Ø AB W/5" EMBEDMENT MINS3.0SCALE: 3/4" = 1'-0"1NEW DROPPED BEAM @ ROOFS3.0SCALE: 3/4" = 1'-0"2NEW CEILING FLUSH BEAMS3.0SCALE: 3/4" = 1'-0"3NEW POST ELEVATIONMAIN FLOORELEVATION(4) SDWH27600SSCREWS TOENAILEDPOST TO BEAMEX. BEAM(4) SDWH27600SSCREWS TOENAILEDPOST TO BEAM16d TOENAILS @ 6" OCBLOCKING TO BEAM PER PLAN(2) 16d TOENAILS EACHRAFTER TO BEAM PER PLANVERIFY OR PROVIDEFULL DEPTH BLOCKINGEACH BAY16d TOENAILS @ 6" OCAPreliminarySheet No.Sheet ContentsJob No.No.DateIssuenickerson engineering2221 Everett Ave #202Everett, WA 98201425.610.4425SIECKE-TROWBRIDGE REMODEL
16740 76TH AVE W
EDMONDS, WA 98026 c Nickerson Engineering, LLC 2020 Thesedrawings were prepared for the"SIECKE-TROWBRIDGE REMODEL" project in EDMONDS, WA. They are notintended for use on any other project.Stated drawing scale is based on36" x 24" sheet.006.08.20Permit05.29.20STRUCTURALDETAILS20-033S3.0RECEIVEDJun 16 2020CITY OF EDMONDSDEVELOPMENT SERVICESDEPARTMENT