APPROVED BLD PLN BLD2021-0037+Mechanical_Plan+1.8.2021_2.16.32_PM+19813171.1 ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4" TO EACH DIMENSION IF THE DUCTWORK IS ON THE INTERIOR OF THE BUILDING. 1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND IS THE HEIGHT. 1.3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT LESS THEN 50, PER IMC 602.2.1. 1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN 1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE 1/2 WATER COLUMN SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS-7. 1.5 ALL DUCT GAUGES PER SMACNA, IMC 603-4. 1.6 ALL DUCT SUPPORTS PER SMACNA, IMC 603-10. 1.7 ATTACH DIFFUSERS AND GRILLES TO T-BAR PER WA STATE & LOCAL CODES. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. GENERAL NOTES DUCTWORK 2.1 INSULATE OR LINE DUCTWORK PER WA. STATE ENERGY AND MECHANICAL CODES. 2.2 INSULATE REFRIGERANT & CONDENSATE PIPING PER STATE & LOCAL ENERGYCODES. INSULATION 3.1 GENERAL CONTRACTOR TO PROVIDE AND CUT OPENINGS FOR ALL ROOFTOP, CEILING,FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING AND FIRE PROOFLININGS PER IMC & IBC. 3.2 GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND DIMENSIONS WITH ERLBEFORE FRAMING OPENINGS. 3.3 GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING ASREQUIRED FOR MECHANICAL WORK. 3.4 GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS REQUIRED FORMECHANICAL WORK. 3.5 GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICALEQUIPMENT. 3.6 GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERL PROVIDE ALLCANT STRIPS AND CURB INSULATION, AND SEAL AGAINST LEAKS. 3.7 GENERAL CONTRACTOR TO PROVIDE ALL CUTTING AND PATCHING OR T-BAR CEILING ASREQUIRED FOR HVAC INSTALLATION. 3.8 GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED FORDUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE 601 OF INTERNATIONAL BUILDINGCODE, WHERE REQUIRED BY SECTION 707 OF IBC. GENERAL CONTRACTOR 4.1 ERL TO INSTALL ALL LOW VOLTAGE CONTROL WIRING, CONDUIT WILL BE PROVIDEDBY ELECTRICAL CONTRACTOR. 4.2 ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS,DISCONNECTS, AND STARTERS FOR MECHANICAL EQUIPMENT. 4.3 ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS,WITH ERL MECHANICAL PLAN AND WITH FIELD LOCATIONS. 4.4 ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHTSWITCH. 4.5 ERL TO PROVIDE 7-DAY NIGHT SETBACK, PROGRAMMABLE TYPE T-STAT WITHCAPABILITY OF 5°F DEADBAND. 4.6 ERL TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER. 4.7 ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL GCFI OUTLET WITHIN 25 FT OFEACH PIECE OF MECHANICAL EQUIPMENT. ELECTRICAL 5.1 PLUMBING CONTRACTOR OFFSETS VENTS 10 FEET MINIMUM FROM ALL HVAC FRESH AIRINTAKES OR 3' ABOVE HIGHEST POINT OF INTAKE, IMC 401.4.1 5.2 CONDENSATE DRAINS FROM RTU BY ERL TO DRAIN WITHIN 12" OF UNIT. CONDENSATE DRAINSFOR AIR HANDLERS BY PLUMBER. PLUMBING 6.1 THE SUPPLY HEATING AND COOLING ENERGY TO EACH ZONE SHALL BE CONTROLLED BYINDIVIDUAL THERMOSTATIC CONTROLS CAPABLE OF RESPONDING TO TEMPERATURE WITHINTHE ZONE. AT MINIMUM, EACH FLOOR SHALL BE CONSIDERED A ZONE. 6.2 OUTDOOR AIR SUPPLY, EXHAUST OPENINGS AND RELIEF OUTLETS SHALL BE PROVIDED WITHCLASS 1A MOTORIZED DAMPERS WHICH CLOSE AUTOMATICALLY WHEN THE SYSTEM IS OFFPER WSEC SECTION C403.2.4.3. ENERGY CODE COMPLIANCE 7.1 WHERE REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS INEACH SYSTEM DELIVERING HEATING OR COOLING AIR IN EXCESS OF 2000 CFM. DETECTORSSHALL BE LOCATED IN THE MAIN RETURN AIR PER IMC 606. MECHANICAL CODE COMPLIANCE WA2015 M T SD S 10"x20" 10"Ø SYMBOL LEGEND NOTE: NOT ALL SYMBOLS SHOWN ON THIS LEGEND MAY PERTAIN TO THIS PROJECT. RECTANGULAR DUCT ROUND DUCT FLEXIBLE DUCT SUPPLY DUCT SECTION RETURN DUCT SECTION FIRE SMOKE DAMPER (120V POWER REQ.) EXHAUST DUCT SECTION SUPPLY DIFFUSER RETURN/EXHAUST GRILLE SIDEWALL DIFFUSER INLINE FAN MANUAL VOLUME DAMPER ZONE DAMPER MOTORIZED DAMPER CEILING MOUNTED EXHAUST FAN FIRE DAMPER THERMOSTAT SMOKE DETECTOR SENSOR RTU 1 CD-1 250 CFM EQUIPMENT TAG DIFFUSER/GRILLE TAG UNDER CUT DOOR COMMISSIONING PLAN ALL COMMISSIONING OF HEATING, VENTILATION AND AIR CONDITIONING SYSTEMS ASREQUIRED BY SECTION C408 "SYSTEM COMMISSIONING" OF THE 2015 WASHINGTON STATE ENERGY CODE (WSEC) SHALL BE PERFORMED BY EVERGREEN REFRIGERATION, LLC. THEACTIVITIES TO BE ACCOMPLISHED ARE PER THE SECTIONS LISTED IN THE"COMMISSIONING COMPLIANCE CHECKLIST" SHOWN BELOW. AT THE COMPLETION OF THEACTIVITIES REQUIRED FOR COMMISSIONING AS DEFINED BY SECTION C408 OF WSEC THE"COMMISSIONING COMPLIANCE CHECKLIST" WILL BE REVIEWED WITH THE BUILDINGOWNER OR THE OWNER'S REPRESENTATIVE AND THIS CERTIFICATION WILL BE SIGNEDAND DATED. THIS WILL SATISFY TO THE CODE OFFICIAL THAT THE REPORT HAS BEENACCEPTED AS REQUIRED BY SECTION C408.1.3 OF WSEC. Commissioning Plan was used during construction and included items below ·A narrative description of activities and the personnel intended to accomplish each one ·Measurable criteria for performance ·Functions to be tested Systems Balancing has been completed ·Air and Hydronic systems are proportionately balanced in a manner to first minimize throttling losses ·Test ports are provided on each pump for measuring pressure across the pump PROJECT INFORMATION COMMISSIONING PLAN (SECTION C408.1.2) SYSTEMS BALANCING (SECTION C408.2.2) FUNCTIONAL TESTING (SECTION C408.2.3) SUPPORTING DOCUMENTS (SECTION C103.6) COMMISSIONING REPORT (SECTION C408.1.4.1) CERTIFICATION HVAC Equipment Functional Testing has been completed (Section C408.2.3.1) HVAC equipment has been tested to demonstrate the installation and operation of components, systems and system-by-system interfacing relationships in accordance with approved plans and specifications COMMISSIONING COMPLIANCE CHECKLIST Project Name: Project Address: Commissioning Authority: HVAC Controls Functional Testing has been completed (Section C408.2.3.2) HVAC controls have been tested to ensure that control devices are calibrated, adjusted and operate properly. sequences of operations have been functionally tested to ensure they operate in accordance with approved plans and specifications Economizers Functional Testing has been completed (Section C408.2.3.3) economizers operate in accordance with manufacturer's specifications Manuals, record documents and training have been completed or are scheduled ·System documentation has been provided to the owner or scheduled date:            ·Record documents have been submitted to owner or scheduled date:            ·Training has been completed or scheduled date:            Preliminary Commissioning Report submitted to Owner and includes items below ·deficiencies found during testing required by this section which have not been corrected at the time of report preparation ·deferred tests, which cannot be performed at the time of report preparation due to climatic conditions. I hereby certify that all requirements for Commissioning have been completed in accordance with the Washington State Energy Code, including all the items above.                              Building Owner or Owner's Representative Date 1 VICINITY MAP NOT TO SCALE DUCT INSULATION TABLE DUCT THICKNESS WSEC REQUIRED INSULATION R-VALUES WSEC 2015 SECTION SYSTEMEXPOSED SUPPLY - INSIDE BUILDING ENVELOPE NONE NONE C403.2.8.2 SQ/RECT SUPPLY - INSIDE BUILDING ENVELOPE 1.0"R-3.3 C403.2.8.2 ROUND SUPPLY/FRESH AIR - INSIDE BUILDING ENVELOPE 1.5"R-3.3 C403.2.8.2 OUTSIDE AIR - INSIDE BUILDING ENVELOPE 2.0"R-7.0 C403.2.8.1 ex 1 SUPPLY/RETURN - OUTSIDE BUILDING ENVELOPE 2.0"R-8.0 C403.2.8.2 RETURN - INSIDE BUILDING ENVELOPE NONE NONE C403.2.8.2 ex 2 ERV - SUPPLY NONE REQUIRED ERV - EXHAUST - OUTSIDE BUILDING ENVELOPE 2.0"R-8.0 C403.2.8.2 RELIEF NONE REQUIRED EXHAUST NONE REQUIRED AIR TERMINAL UNIT SCHEDULE ITEM MARK MANF.MODEL MATERIAL FINISH SIZE NOTES CEILING DIFFUSER CD-1 PRICE SMCD STEEL WHITE SEE SCHEDULE BORDER TYPE 36 = T-BAR BORDER TYPE 6 = HARD LID CEILING GRILLE CG-1 PRICE 80 ALUMINUM WHITE NECK SIZE SQ.BORDER TYPE F = T-BAR BORDER TYPE F = HARD LID NOTES: ADD MECHANICAL VOLUME DAMPER TO EACH SUPPLY DIFFUSER BRANCH. ADD MECHANICAL VOLUME DAMPER TO EACH EXHAUST INTAKE GRILLE BRANCH. SUPPLY DIFFUSER SIZE SIZE RANGE 6" X 6"0 - 100 CFM 8" X 8"101 - 250 CFM 10" X 10"251 - 425 CFM 12" X 12"426 - 650 CFM GAS HEAT / ELECTRIC COOL PACKAGED EQUIPMENT SCHEDULE MARK MANF.MODEL TONS AIRFLOW SP MOTOR DRIVE STYLE COOLING HEATING ELECTRICAL WEIGHT FILTER SIZES NOTESTOTAL SEER EER INPUT OUTPUT AFUE VOLTS PHASE M.C.A. (CFM)(in. W.G.)(hp)(BTU/h)(BTU/h)(BTU/h)(%)(V)(A)(lb)No. (LxWxD) RTU-1 TRANE YSC036G3EMB 3 1,200 0.5 0.75 DD 36,970 14.0 12.0 100,000 81,000 81 208 3 19.9 747 2 (20x35x2)1,2,3,4 NOTES: 1. THE ROOFTOP UNIT COMES COMPLETE WITH AN ECONOMIZER 2. CONDENSATE BY PLUMBING CONTRACTOR. 3. WIRING BY ELECTRICAL CONTRACTOR. 4. CONNECT TO EXISTING DUCT DROPS SPLIT SYSTEM HEAT PUMP UNIT SCHEDULE MARK MANF.MODEL TONS AIRFLOW COOLING HEATING ELECTRICAL WEIGHT TYPE NOTESTOTAL SEER EER TOTAL VOLTS PHASE M.C.A. (CFM)(BTU/h)(BTU/h)HSPF (V)(A)(lb) IU-1 MITSUBISHI MSZ-GL09NA .75 399 9,000 10,900 208 1 1 22 WALL MOUNTED 1,2,3 OU-1 MITSUBISHI MUZ-GL09NA .75 9,000 24.6 15.4 10,900 12.8 208 1 9 81 1,2 IU-2A MITSUBISHI MSZ-GL09NA .75 399 9,000 10,900 208 1 1 22 WALL MOUNTED 1,2,3 IU-2B MITSUBISHI MSZ-GL09NA .75 399 9,000 10,900 208 1 1 22 WALL MOUNTED 1,2,3 OU-2 MITSUBISHI MXZ-2C20NA2 1.5 20,000 20.0 12.7 25,000 10.0 208 1 17.2 126 1,2 IU-3 MITSUBISHI MSZ-GL12NA 1 406 12,000 14,400 208 1 1 22 WALL MOUNTED 1,2,3,4 OU-3 MITSUBISHI MUZ-GL12NA 1 12,000 23.1 13.0 14,400 12.5 208 1 1 22 1,2,3 IU-4 MITSUBISHI MSZ-GL09NA .75 399 9,000 10,900 208 1 1 22 WALL MOUNTED 1,2,3 OU-4 MITSUBISHI MUZ-GL09NA .75 9,000 24.6 15.4 10,900 12.8 208 1 9 81 1,2 IU-5 MITSUBISHI MSZ-GL18NA 1.5 646 18,000 21,600 1 28 WALL MOUNTED 1,2,3 OU-5 MITSUBISHI MUZ-GL18NA 1.5 18,000 20.5 13.4 21,600 11.2 208 1 14 121 1,2 IU-6 MITSUBISHI MSZ-GL09NA .75 399 9,000 10,900 208 1 1 22 WALL MOUNTED 1,2,3 OU-6 MITSUBISHI MUZ-GL09NA .75 9,000 24.6 15.4 10,900 12.8 208 1 9 81 1,2 IU-7 MITSUBISHI MSZ-GL12NA 1 406 12,000 14,400 208 1 1 22 WALL MOUNTED 1,2,3 OU-7 MITSUBISHI MUZ-GL12NA 1 12,000 23.1 13.0 14,400 12.5 208 1 1 22 1,2,3 IU-8A MITSUBISHI MSZ-GL09NA .75 399 9,000 10,900 208 1 1 22 WALL MOUNTED 1,2,3 IU-8B MITSUBISHI MSZ-GL09NA .75 399 9,000 10,900 208 1 1 22 WALL MOUNTED 1,2,3 OU-8 MITSUBISHI MXZ-2C20NA2 1.5 20,000 20.0 12.7 25,000 10.0 208 1 17.2 126 1,2 IU-9A MITSUBISHI MSZ-GL24NA 2 738 22,500 27,600 208 1 1 37 WALL MOUNTED 1,2,3 IU-9B MITSUBISHI MSZ-GL24NA 2 738 22,500 27,600 208 1 1 37 WALL MOUNTED 1,2,3 IU-9C MITSUBISHI MSZ-GL12NA 1 406 12,000 14,400 208 1 1 22 WALL MOUNTED 1,2,3 OU-9 MITSUBISHI MXZ-8C60NA 5 60,000 17.4 12.5 66,000 10.5 208 1 46 309 1,2 NOTES: 1. CONDENSATE PUMP BY ERL, CONDENSATE TO DRAIN TO APPROVED LOCATION BY PLUMBING CONTRACTOR. 2. WIRING BY ELECTRICAL CONTRACTOR. 3. ECONOMIZER NOT REQUIRED PER 2015 WSEC C403.3 EXCEPTION #1 4. WITH EXISTING CONDENSING UNIT ENERGY RECOVERY VENTILATOR SCHEDULE MARK MANF.MODEL CFM S.P.EFF. RATE VOLTS PHASE MCA NOTES ERV-1 PANASONIC FV-04VE1 40 0.1 55%120 1Ø 0.15 1,2 ERV-2 PANASONIC FV-04VE1 40 0.1 55%120 1Ø 0.15 1,2 ERV-3 PANASONIC FV-04VE1 40 0.1 55%120 1Ø 0.15 1,2 ERV-4 PANASONIC FV-04VE1 40 0.1 55%120 1Ø 0.15 1,2 ERV-5 PANASONIC FV-04VE1 40 0.1 55%120 1Ø 0.15 1,2 ERV-6 PANASONIC FV-04VE1 40 0.1 55%120 1Ø 0.15 1,2 ERV-7 PANASONIC FV-04VE1 40 0.1 55%120 1Ø 0.15 1,2 ERV-8 RUSKIN EVT O11-02 300 0.5 72%208 1Ø 20.8 1,3 ERV-9 RUSKIN EVT O11-02 300 0.5 72%208 1Ø 20.8 1,3 NOTES: 1. SET TO RUN AT HIGH SPEED 2. SET TO RUN CONTINUOUSLY 3. MOUNT ON FACTORY SUPPLIED CURB GOVERNING CODE INFORMATION 2015 INTERNATIONAL BUILDING CODE WITH STATEWIDE AMENDMENTS 2015 INTERNATIONAL MECHANICAL CODE WITH STATEWIDE AMENDMENTS 2015 INTERNATIONAL FIRE CODE WITH STATEWIDE AMENDMENTS 2015 INTERNATIONAL ENERGY CONSERVATION CODE/WASHINGTON STATE ENERGY CODE 2015 INTERNATIONAL EXISTING BUILDING CODE WITH STATEWIDE AMENDMENTS FOUND IN THE IBC DWG BY: CKD BY: JOB NO.: SHEET: NOT PUBLISHED. ALL RIGHTS RESERVED. THE DRAWING AND SPECIFICATIONS, IDEAS, DESIGN AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVERGREEN REFRIGERATION LLC. NO PART THERE OF SHALL BE DISTRIBUTED TO OTHERS, SOLD, PUBLISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPENSTATION TO EVERGREEN REFRIGERATION LLC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. PERMIT SET DATE: ISSUED FOR DATE: AS BUILT DATE: CONSTRUCTION 727 SOUTH KENYON STREETSEATTLE, WASHINGTON 98108PHONE: (206)-763-1744www.evergreenhvac.comEVERGRL954R2520292 12-22-20 ---- ----21500 72ND AVE WEDMONDS, WA 98026SUNRISE OF LYNWOODENGINEER'S STAMP HEREREV.DATEDESCRIPTION11/5/21PERMIT DRAWINGSM001 SUNRISE OF LYNWOOD JV MG/AFCOVER SHEETCOVER SHEET 1 AREA OF WORK NOT TO SCALE UP UP REF.REF.REF.REF.REF.REF.REF.REF.REF. REF. REF. REF. REF. REF. REF.REF.REF.REF.11 2 2 33 4 4 55 11 12 1.11.1 3.9 3.9 6 6 7 8 9 10 A A A.1 A.1 B B C C D D D.9 D.9 E E F F G G H J K L M N STUDIO-01 U101 STUDIO-01 U103 STUDIO-01 U105 2 BEDROOM RESIDENT UNIT U108 STUDIO-01 U106 STUDIO-01 U104 STUDIO-01 U102 STUDIO-01 U100 STUDIO-01 U125 STUDIO-01 U123 STUDIO-01 U121 STUDIO-01 U115 STUDIO-01 U122 STUDIO-01 U120 STUDIO-01 U118 2 BEDROOM RESIDENT UNIT U116 STUDIO-01 U119 LIVING 113 STUDIO-01 U124 STUDIO-01 U107 LIVING 110 SOILED RM E134 CLEAN UTIL E135 SPA/ TOILET E109 JANITOR E125 STORAGE E124 VESTIBULE E144 LOBBY 150 CORRIDOR123CORRIDOR 122 CRAWL SPACE E136A LAUNDRY E136 ELECTRICAL E137 ELEC. AND TELE. E147 ELEV. EQUIP. E148 MECH E149 OFFICE E130 OFFICE E131 CORRIDOR E128 CORRIDORE129STORAGE E146 STAIR E143 STAIR E141 STAIR E142 BISTRO 151 CONCIERGE 152OFFICE 153 City Of Edmonds Building Department Work Address Owner Approved Date Building Official Permit Number MECHANIICAL 2100 2ND AVE W SUNRISE RECEIVED Jan 12 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2021-0037 APPROVED BY PLANNING Jan 21 2021 All Fire Rated assemblies shall be maintained and inspected prior to cover. ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE 1-28-2021 Eric Carter UP REF.REF.REF.REF.REF.REF.REF.REF. REF. REF. REF.REF.REF.REF.11 2 2 33 4 4 55 1.11.1 3.9 3.9 6 6 7 8 9 A A.1 B C D D.9 E F G H J K L M N STUDIO-01 U103 STUDIO-01 U105 2 BEDROOM RESIDENT UNIT U108 STUDIO-01 U106 STUDIO-01 U104 STUDIO-01 U102 STUDIO-01 U125 STUDIO-01 U123 STUDIO-01 U121 STUDIO-01 U115 STUDIO-01 U122 STUDIO-01 U120 STUDIO-01 U118 2 BEDROOM RESIDENT UNIT U116 STUDIO-01 U119 LIVING 113 STUDIO-01 U124 STUDIO-01 U107 LIVING 110 SOILED RM E134 CLEAN UTIL E135 SPA/ TOILET E109 JANITOR E125 STORAGE E124 VESTIBULE E144 LOBBY 150 CORRIDOR123CORRIDOR 122 CRAWL SPACE E136A LAUNDRY E136 ELECTRICAL E137 ELEC. AND TELE. E147 ELEV. EQUIP. E148 MECH E149 OFFICE E130 OFFICE E131 CORRIDOR E128 CORRIDORE129STORAGE E146 STAIR E143 STAIR E142 BISTRO 151 CONCIERGE 152OFFICE 153 1 1ST FLOOR HVAC PLAN SCALE: 1/8"=1' ERV 1 ERV 2 ERV 3 IU 1 IU 2A IU 2B 4Ø UP TO SECOND FLOOR 3.5"x10" UP TO ROOF DUCT TO RUN UP THROUGH WALL DWG BY: CKD BY: JOB NO.: SHEET: NOT PUBLISHED. ALL RIGHTS RESERVED. THE DRAWING AND SPECIFICATIONS, IDEAS, DESIGN AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVERGREEN REFRIGERATION LLC. NO PART THERE OF SHALL BE DISTRIBUTED TO OTHERS, SOLD, PUBLISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPENSTATION TO EVERGREEN REFRIGERATION LLC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. PERMIT SET DATE: ISSUED FOR DATE: AS BUILT DATE: CONSTRUCTION 727 SOUTH KENYON STREETSEATTLE, WASHINGTON 98108PHONE: (206)-763-1744www.evergreenhvac.comEVERGRL954R2520292 12-22-20 ---- ----21500 72ND AVE WEDMONDS, WA 98026SUNRISE OF LYNWOODENGINEER'S STAMP HEREREV.DATEDESCRIPTION11/5/21PERMIT DRAWINGSM201 SUNRISE OF LYNWOOD JV MG/AFFIRST FLOOR HVAC PLAN1ST FLOOR PLAN 1 1 RECEIVED Jan 12 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DN REF.REF.REF.REF.REF.REF.REF.REF.REF. REF. REF.REF.REF. 11 2 2 33 4 4 55 1.11.1 3.9 3.9 6 6 7 8 9 A A.1 B C D D.9 E F G H J K L M N STUDIO-01 U202 STUDIO-01 U203 STUDIO-01 U204 STUDIO-01 U205 STUDIO-01 U206 1 BEDROOM RESIDENT UNIT U208 1 BEDROOM RESIDENT UNIT U209 KITCHEN STORAGE E210A STAFF E210B STUDIO-01 U215 1 BEDROOM RESIDENT UNIT U216 1 BEDROOM RESIDENT UNIT U217 STUDIO-01 U218 STUDIO-01 U219 STUDIO-01 U220 STUDIO-01 U221 STUDIO-01 U222 STUDIO-01 U223 STUDIO-01 U224 STUDIO-01 U225 CORRIDOR E222 CORRIDOR E223 CORRIDOR E228 CORRIDOR229LAUNDRY E224 TOILET E225 TOILET E226 OFFICE 227 LOUNGE 230KITCHEN E236 DINING ROOM 235 STAFF E234 STORAGE E233 VESTIBULE E237 STAIR E242 STAIR E243 STORAGE E247 JANITOR E248 MECH E249 SHAFT SH 2B SHAFT SH 2A SHAFT SH 2C SHAFT SH 2D STUDIO-01 U207 1 2ND FLOOR HVAC PLAN SCALE: 1/8"=1' ERV 5 ERV 4 IU 3 IU 4 IU 5 OU 3 CD-1 100 CFM CG-1 100 CFM 4Ø 4Ø 4Ø 4Ø REBALANCE TO 600 CFM EACH 6Ø 6Ø 3.5"x10" UP TO ERV-12 6Ø UP TO ROOF DWG BY: CKD BY: JOB NO.: SHEET: NOT PUBLISHED. ALL RIGHTS RESERVED. THE DRAWING AND SPECIFICATIONS, IDEAS, DESIGN AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVERGREEN REFRIGERATION LLC. NO PART THERE OF SHALL BE DISTRIBUTED TO OTHERS, SOLD, PUBLISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPENSTATION TO EVERGREEN REFRIGERATION LLC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. PERMIT SET DATE: ISSUED FOR DATE: AS BUILT DATE: CONSTRUCTION 727 SOUTH KENYON STREETSEATTLE, WASHINGTON 98108PHONE: (206)-763-1744www.evergreenhvac.comEVERGRL954R2520292 12-22-20 ---- ----21500 72ND AVE WEDMONDS, WA 98026SUNRISE OF LYNWOODENGINEER'S STAMP HEREREV.DATEDESCRIPTION11/5/21PERMIT DRAWINGSM202 SUNRISE OF LYNWOOD JV MG/AFSECOND FLOOR HVAC PLAN2ND FLOOR PLAN WALL MOUNT WALL CAP WALL CAP 1 1 RECEIVED Jan 12 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT REF.REF.REF.REF.REF.REF.REF.REF.REF. REF. REF.REF.REF. REF. 11 2 2 33 4 4 55 1.11.1 3.9 3.9 6 6 7 8 9 A A.1 B C D D.9 E F G H J K L M N STUDIO-01 U302 STUDIO-01 U303 STUDIO-01 U304 STUDIO-01 U305 STUDIO-01 U306 STUDIO-01 U307 1 BEDROOM RESIDENT UNIT U308 1 BEDROOM RESIDENT UNIT U309 STUDIO-01 U310 STUDIO-01 U315 1 BEDROOM RESIDENT UNIT U316 1 BEDROOM RESIDENT UNIT U317 STUDIO-01 U318 STUDIO-01 U319 STUDIO-01 U320 STUDIO-01 U321 STUDIO-01 U322 STUDIO-01 U323 STUDIO-01 U324 STUDIO-01 U325 CORRIDOR E322 CORRIDOR E323 LAUNDRY E324 TOILET E325 TOILET E326 CORRIDOR E327 CORRIDOR 328 OFFICE E329 HAIR SALON E330 LOUNGE E331A WET ACTIVITY 332 LIVING ROOM 333 STUDIO-02 U334 STUDIO-02 U335 STORAGE E347 JANITOR E348 MECH E349 STAIR E342 STAIR E343SHAFT SH 3B SHAFT SH 3C SHAFT SH 3D SHAFT SH 3A NURSING E331B CD-1 300 CFM 1 3RD FLOOR HVAC PLAN SCALE: 1/8"=1' ERV 6 ERV 7 IU 6 IU 7 IU 8A IU 10 IU 9A IU 9C IU 9B CG-1 DUCT TO RUN ON ROOF 4Ø UP TO ROOF 4Ø UP TO ROOF 4Ø UP TO ROOF CD-1 100 CFM CG-1 100 CFM DWG BY: CKD BY: JOB NO.: SHEET: NOT PUBLISHED. ALL RIGHTS RESERVED. THE DRAWING AND SPECIFICATIONS, IDEAS, DESIGN AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVERGREEN REFRIGERATION LLC. NO PART THERE OF SHALL BE DISTRIBUTED TO OTHERS, SOLD, PUBLISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPENSTATION TO EVERGREEN REFRIGERATION LLC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. PERMIT SET DATE: ISSUED FOR DATE: AS BUILT DATE: CONSTRUCTION 727 SOUTH KENYON STREETSEATTLE, WASHINGTON 98108PHONE: (206)-763-1744www.evergreenhvac.comEVERGRL954R2520292 12-22-20 ---- ----21500 72ND AVE WEDMONDS, WA 98026SUNRISE OF LYNWOODENGINEER'S STAMP HEREREV.DATEDESCRIPTION11/5/21PERMIT DRAWINGSM203 SUNRISE OF LYNWOOD JV MG/AFTHIRD FLOOR HVAC PLAN3RD FLOOR PLAN 1 1 RECEIVED Jan 12 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 11 2 2 33 4 4 55 1.11.1 3.9 3.9 6 6 7 8 9 A A.1 B C D D.9 E F G H J K L M N 1 ROOF HVAC PLAN SCALE: 1/8"=1' RTU 1 OU 7 OU 4 OU 1 OU 6 OU 2 OU 8 OU 9 OU 5 ERV 8 10x8 10x8 ATTACH NEW RTU TO EXISTING DUCT DROPS CAP ALL DUCT WORK NOT SERVING DINING ROOM 235 NEW ROOFTOP DUCT ERV 9 NEW ROOFTOP DUCT 8Ø 8Ø 10x8 10x8 DWG BY: CKD BY: JOB NO.: SHEET: NOT PUBLISHED. ALL RIGHTS RESERVED. THE DRAWING AND SPECIFICATIONS, IDEAS, DESIGN AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVERGREEN REFRIGERATION LLC. NO PART THERE OF SHALL BE DISTRIBUTED TO OTHERS, SOLD, PUBLISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPENSTATION TO EVERGREEN REFRIGERATION LLC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. PERMIT SET DATE: ISSUED FOR DATE: AS BUILT DATE: CONSTRUCTION 727 SOUTH KENYON STREETSEATTLE, WASHINGTON 98108PHONE: (206)-763-1744www.evergreenhvac.comEVERGRL954R2520292 12-22-20 ---- ----21500 72ND AVE WEDMONDS, WA 98026SUNRISE OF LYNWOODENGINEER'S STAMP HEREREV.DATEDESCRIPTION11/5/21PERMIT DRAWINGSM204 SUNRISE OF LYNWOOD JV MG/AFROOF PLANROOF PLAN 1 1 RECEIVED Jan 12 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PANASONIC FV-04VE1 ERV MATERIAL LIST (PER UNIT) PANASONIC FV-04VE1 PER EQUIPMENT SCHEDULE1 SCALE: NONE FV-04VE1 SEQUENCE OF OPERATIONS - TIME CLOCK ENERGIZES G GREEN WHT BLK YEL ORG BLU JUMPER SWITCH TERMINALS INTERMATIC GM40AV-QW 120 V TIME CLOCK1 - DAMPERS OPEN AND UNIT TURNS ON MOTORIZED DAMPER TIME CLOCK ACTUATOR-BELIMO LF120-US 120 VOLT BY ERL MOTORIZED DAMPER ACTUATOR-BELIMO LF120-US OUTSIDE AIR EXHAUST AIR H 120 VOLT N - TIME CLOCK DE-ENERGIZES - DAMPERS CLOSES AND UNIT TURNS OFFBELIMO LF120-US ACTUATOR2 ALL EQUIPMENT AND CONTROLS PROVIDED BY ERL AND WIRED BY ELECTRICAL CONTRACTOR. TIME CLOCK TO BE SET FOR OCCUPIED HOURS. SCALE : NONE PANASONIC ERV/ MOTORIZED DAMPER DETAIL MOTORIZED DAMPER TIME CLOCK ACTUATOR-BELIMO LF120-US 120 VOLT BY ERL ALL EQUIPMENT AND CONTROLS PROVIDED BY ERL AND WIRED BY ELECTRICAL CONTRACTOR. TIME CLOCK TO BE SET FOR OCCUPIED HOURS. MOTORIZED DAMPER ACTUATOR-BELIMO LF120-USL N PANASONIC ERV OUTSIDE AIR EXHAUST AIR H 120 VOLT N MATERIAL LIST PANASONIC FV-10VE1 ERV INTERMATIC GM40AV-QW 120 V TIME CLOCK BELIMO LF120-US ACTUATOR 1 1 2 G 1020 30 40 50 60 5060 70 80 90 100 5060 70 80 90 100 FILTER RESET BUTTON EXHAUST AIR CFM SUPPLY AIR CFM MIN/H CONTROL PANEL FV-10VE1 SEQUENCE OF OPERATIONS - TIME CLOCK ENERGIZES - DAMPER OPENS AND UNIT TURNS ON - TIME CLOCK DE-ENERGIZES - DAMPER CLOSES AND UNIT TURNS OFF SCALE : NONE TIME CLOCK 120 VOLT BY ERL UNIT TRANSFORMER RELAY RUSKIN ERV 24V+ WIRING BY ERL MATERIAL LIST RUSKIN ERV INTERMATIC GM40AV-QW 120 V TIME CLOCK FUN RIBU1C RELAY 1 1 1 SEQUENCE OF OPERATIONS -TIME CLOCK ENERGIZES -DAMPERS OPEN AND UNIT TURNS ON -TIME CLOCK DE-ENERGIZES -DAMPERS CLOSE AND UNIT TURNS OFF 1 TERMINAL BLOCK RUSKIN ERV WIRING DETAIL NOTE: ON/OFF SWITCH TIMER: WIRE 24V+ FROM TRANSFORMER ONTO THE INPUT OF THE SWITCH AND CONNECT THE OUTPUT OF THE SWITCH TO TERMINAL 1 ON THE CONTROL BOARD. THE ERV CAN BE TURNED ON MANUALLY OR BE SET TO TURN ON AT REGULAR SCHEDULE WHEN BUILDING IS OCCUPIED 24V+ WIRING BY ERL DWG BY: CKD BY: JOB NO.: SHEET: NOT PUBLISHED. ALL RIGHTS RESERVED. THE DRAWING AND SPECIFICATIONS, IDEAS, DESIGN AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVERGREEN REFRIGERATION LLC. NO PART THERE OF SHALL BE DISTRIBUTED TO OTHERS, SOLD, PUBLISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPENSTATION TO EVERGREEN REFRIGERATION LLC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. PERMIT SET DATE: ISSUED FOR DATE: AS BUILT DATE: CONSTRUCTION 727 SOUTH KENYON STREETSEATTLE, WASHINGTON 98108PHONE: (206)-763-1744www.evergreenhvac.comEVERGRL954R2520292 12-22-20 ---- ----21500 72ND AVE WEDMONDS, WA 98026SUNRISE OF LYNWOODENGINEER'S STAMP HEREREV.DATEDESCRIPTION11/5/21PERMIT DRAWINGSM601 SUNRISE OF LYNWOOD JV MG/AFWIRING DIAGRAMWIRING DIAGRAMS RECEIVED Jan 12 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DWG BY: CKD BY: JOB NO.: SHEET: NOT PUBLISHED. ALL RIGHTS RESERVED. THE DRAWING AND SPECIFICATIONS, IDEAS, DESIGN AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVERGREEN REFRIGERATION LLC. NO PART THERE OF SHALL BE DISTRIBUTED TO OTHERS, SOLD, PUBLISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPENSTATION TO EVERGREEN REFRIGERATION LLC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. PERMIT SET DATE: ISSUED FOR DATE: AS BUILT DATE: CONSTRUCTION 727 SOUTH KENYON STREETSEATTLE, WASHINGTON 98108PHONE: (206)-763-1744www.evergreenhvac.comEVERGRL954R2520292 12-22-20 ---- ----21500 72ND AVE WEDMONDS, WA 98026SUNRISE OF LYNWOODENGINEER'S STAMP HEREREV.DATEDESCRIPTIONSUNRISE OF LYNWOOD JV MG/AF WIRING DIAGRAMS INC 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512(V) (206) 285-0618(F) bmccann@ctengineering.com #20227 Structural Construction Documents For: SUNRISE OF LYNNWOOD RTU SUPPORT AT 21500 72nd Ave W Edmonds, WA 98026 Client: Evergreen Refrigeration & HVAC 727 S. Kenyon St. Seattle, WA 98108 Design Criteria: IBC 2015 Wind: Wind Speed = 110 mph, Kzt = 1.00 Seismic: Sds = .9 Roof Snow Load = 25 psf C T E N G I N E E R I N G 09/28/202012/23/2020 RTU TO BE REMOVED AND REPLACED WITH NEW. NO CURB ADAPTER.(E) 2X10 @24 " O.C.(E) PRIMARY BEAM LINESREFERENCE DETAIL A NEXT SHEET FOR ANCHORAGE REQUIREMENTS. Sunrise of Lynnwood 12/23/2020 M701STRUCTURAL DETAILSRECEIVED Jan 12 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT