Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
REVIEWED BLD2021-0037+Manufacturer_Specifications_and_Installation_Instructions+1.8.2021_2.14.47_PM+1981309
Trane Precedent Gas/Electric Packaged Rooftop Unit Overview - YSC036G3EMB**000000000000000000000000000 Application Unit Size Supply Fan External Dimensions (in.)Weight EER IEER/SEER DX cooling, gas heat 3 Ton (036)Airflow External Static Pressure Height Width Length Minimum Maximum 12.0 EER 1200 cfm 0.500 in H2O 3.41 ft 3.69 ft 5.82 ft 472.0 lb 747.0 lb Unit Features Unit Electrical Voltage/phase/hertz 208-230/60/3 MCA 19.90 A MOP 30.00 A Controls Unit Controls Electro mechanical controls 3ph Cooling Section Entering Dry Bulb 80.00 F Entering Wet Bulb 67.00 F Ambient Temp 95.00 F Leaving Coil Dry Bulb 57.21 F Leaving Coil Wet Bulb 57.21 F Leaving Unit Dry Bulb 58.99 F Leaving Unit Wet Bulb 57.90 F Refrigeration System Options Leaving Dew Point 57.21 F Capacity Gross Total 36.97 MBh Gross Sensible 29.79 MBh Net Total 35.94 MBh Net Sensible 28.76 MBh Fan Motor Heat 1.03 MBh Refrig Charge-circuit 1 3.2 lb Heating Section Heating Stages 2 Output Heating Capacity 81.00 MBh Output Heating Capacity with Fan 82.25 MBh Heating EAT 70.00 F Heating LAT 132.70 F Heating Temp Rise 62.70 F Fan Section Indoor Fan Data Type FC Centrifugal Drive Type Direct Indoor Fan Performance Airflow 1200 cfm Design ESP 0.500 in H2O Indoor Motor Operating Power 0.40 bhp Indoor Motor Power 0.30 kW Indoor RPM 918 rpm Indoor Fan FLA 0.00 A Outdoor Fan Data Type Propeller Fan Quantity 1 Drive Type Direct Outdoor Fan Performance Condenser Fan FLA 0.00 A Exhaust Fan Data Type FC Centrifugal Drive Type Direct Exhaust Fan Performance Exhaust Fan FLA 0.00 A Compressor Section Power 0.00 kW Circuit 1 RLA 0.00 A Circuit 2 RLA 1.10 A Job Name: GENSCO STOCK Prepared By: GENSCO STOCK Unit Tag: YSC036G3EMB00 Quantity: 1 2018-04-25 21:14:40Z Page 1 of 9 RECEIVED Jan 12 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2021-0037REVIEWED BY CITY OF EDMONDS Job Name: GENSCO STOCK Prepared By: GENSCO STOCK Unit Tag: YSC036G3EMB00 Quantity: 1 2018-04-25 21:14:40Z Page 2 of 9 Job Name: GENSCO STOCK Prepared By: GENSCO STOCK Unit Tag: YSC036G3EMB00 Quantity: 1 2018-04-25 21:14:40Z Page 3 of 9 Job Name: GENSCO STOCK Prepared By: GENSCO STOCK Unit Tag: YSC036G3EMB00 Quantity: 1 2018-04-25 21:14:40Z Page 4 of 9 Job Name: GENSCO STOCK Prepared By: GENSCO STOCK Unit Tag: YSC036G3EMB00 Quantity: 1 2018-04-25 21:14:40Z Page 5 of 9 Job Name: GENSCO STOCK Prepared By: GENSCO STOCK Unit Tag: YSC036G3EMB00 Quantity: 1 2018-04-25 21:14:40Z Page 6 of 9 General The units shall be convertible airflow. The operating range shall be between 115°F and 0°F in cooling as standard from the factory for units with microprocessor controls. Operating range for units with electromechanical controls shall be between 115°F and 40°F. Cooling performance shall be rated in accordance with ARI testing procedures. All units shall be factory assembled, internally wired, fully charged with R-410A, and 100 percent run tested to check cooling operation, fan and blower rotation, and control sequence before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be cULus listed and labeled, classified in accordance for Central Cooling Air Conditioners. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather-resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM B117. Cabinet construction shall allow for all maintenance on one side of the unit. Service panels shall have lifting handles and be removed and reinstalled by removing two fasteners while providing a water and air tight seal. All exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil- faced, fire-retardant permanent, odorless glass fiber material. The base of the unit shall be insulated with 1/8 inch, foil-faced, closed-cell insulation. All insulation edges shall be either captured or sealed. The unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8 inch high downflow supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting, with forklift capabilities on three sides of the unit. Unit Top The top cover shall be one piece construction or, where seams exist, it shall be double-hemmed and gasket-sealed. The ribbed top adds extra strength and enhances water removal from unit top. Filters Throwaway filters shall be standard on all units. Optional 2-inch MERV 8 and MERV 13 filters shall also be available. Compressors All units shall have direct-drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll compressors. Dual compressors are outstanding for humidity control, light load cooling conditions and system back- up applications. Dual compressors are available on 7½-10 ton models and allow for efficient cooling utilizing 3-stages of compressor operation for all high efficiency models. Indoor Fan The following units shall be equipped with a direct drive plenum fan design (T/YSC120F,T/YHC074F, T/YHC092F,T/YHC102F, 120F). Plenum fan design shall include a backward-curved fan wheel along with an external rotor direct drive variable speed indoor motor. All plenum fan designs will have a variable speed adjustment potentiometer located in the control box. 3 to 5 ton units (high efficiency 3-phase with optional motor) are belt driven, FC centrifugal fans with adjustable motor sheaves. 3 to 5 ton units (standard and high efficiency 3-phase) have multispeed, direct drive motors. All 6 to 8½ ton units (standard efficiency) shall have belt drive motors with an adjustable idler-arm assembly for quick-adjustment to fan belts and motor sheaves. All motors shall be thermally protected. All 10 tons, 6 ton (074), 7½ to 8½ (high efficiency) units have variable speed direct drive motors. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). Job Name: GENSCO STOCK Prepared By: GENSCO STOCK Unit Tag: YSC036G3EMB00 Quantity: 1 2018-04-25 21:14:40Z Page 7 of 9 Outdoor Fans The outdoor fan shall be direct-drive, statically and dynamically balanced, draw-through in the vertical discharge position. The fan motor shall be permanently lubricated and shall have built-in thermal overload protection. Evaporator and Condenser Coils Internally finned, 5/16" copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. Evaporator coils are standard for all 3 to 10 ton standard efficiency models. Microchannel condenser coils are standard for all 3 to 10 ton standard efficiency models and 4, 5, 6, 7.5, 8.5 ton high efficiency models. The microchannel type condenser coil is not offered on the 4 and 5 ton dehumidification model. Due to flat streamlined tubes with small ports, and metallurgical tube-to-fin bond, microchannel coil has better heat transfer performance. Microchannel condenser coil can reduce system refrigerant charge by up to 50% because of smaller internal volume, which leads to better compressor reliability. Compact all-aluminum microchannel coils also help to reduce the unit weight. These all aluminum coils are recyclable. Galvanic corrosion is also minimized due to all aluminum construction. Strong aluminum brazed structure provides better fin protection. In addition, flat streamlined tubes also make microchannel coils more dust resistant and easier to clean. Coils shall be leak tested at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 600 psig. The assembled unit shall be leak tested to 465 psig. The condenser coil shall have a patent pending 1+1+1 hybrid coil designed with slight gaps for ease of cleaning. A plastic, dual-sloped, removable and reversible condensate drain pan with through-the-base condensate drain is standard. Controls Unit shall be completely factory-wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. A choice of microprocessor or electromechanical controls shall be available. Microprocessor controls provide for all 24V control functions. The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort. A centralized microprocessor shall provide anti- short cycle timing and time delay between compressors to provide a higher level of machine protection. 24-volt electromechanical control circuit shall include control transformer and contactor High Pressure Control All units include High Pressure Cutout as standard. Phase monitor Phase monitor shall provide 100% protection for motors and compressors against problems caused by phase loss, phase imbalance, and phase reversal. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. There are no field adjustments. The module will automatically reset from a fault condition. Refrigerant Circuits Each refrigerant circuit offer thermal expansion valve as standard. Service pressure ports, and refrigerant line filter driers are factory-installed as standard. An area shall be provided for replacement suction line driers. Job Name: GENSCO STOCK Prepared By: GENSCO STOCK Unit Tag: YSC036G3EMB00 Quantity: 1 2018-04-25 21:14:40Z Page 8 of 9 Gas Heating Section The heating section shall have a progressive tubular heat exchanger design using stainless steel burners and corrosion resistant steel throughout. An induced draft combustion blower shall be used to pull the combustion products through the firing tubes. The heater shall use a direct spark ignition (DSI) system. On initial call for heat, the combustion blower shall purge the heat exchanger for 20 seconds before ignition After three unsuccessful ignition attempts, the entire heating system shall be locked out until manually reset at the thermostat/zone sensor. Units shall be suitable for use with natural gas or propane (field-installed kit) and also comply with the California requirement for low NOx emissions (Gas/Electric Only). Job Name: GENSCO STOCK Prepared By: GENSCO STOCK Unit Tag: YSC036G3EMB00 Quantity: 1 2018-04-25 21:14:40Z Page 9 of 9 Job Name: System Reference:Date: Indoor Unit: MSZ-GL12NA Wireless Remote Controller GENERAL FEATURES • Slim wall-mounted indoor units provide zone comfort control • The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns • Multiple fan speed options: Quiet, Low, Medium, High, Super-high, Auto • Multiple control options available: - Hand-held Remote Controller (provided with unit) - kumo cloud® smart device app for remote access - Third-party interface options - Wired or wireless controllers • Hot-Start Technology: no cold air rush at equipment startup or when restarting after Defrost Cycle • Quiet operation • Smart Set: recalls a preferred preset temperature setting at the touch of a button SUBMITTAL DATA: MSZ-GL12NA 12,000 BTU/H WALL-MOUNTED INDOOR UNIT FOR MXZ-C MULTI-ZONE HEAT-PUMP SYSTEMS Specifications are subject to change without notice.© 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. M-SERIES Cooling Capacity1 Btu/h 12,000 Heating Capacity2 Btu/h 14,400 Electrical Voltage, Phase, Frequency 208/230V, 1 phase, 60Hz Guaranteed Voltage Range V AC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 V AC 208 / 230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Voltage: Indoor - Remote controller V DC 12 MCA A 1 Blower Motor Full Load Amperage A 0.76 Blower Motor Output W 30 Airflow Rate at Cooling, Dry CFM 399-321-237-170-145 Airflow Rate at Cooling, Wet CFM 364-286-201-134-109 Airflow Rate at Heating, Dry CFM 406-321-237-170-145 Sound Pressure Level (Cooling)dB(A)45-37-30-22-19 Sound Pressure Level (Heating)dB(A)43-37-30-22-19 Drain Pipe Size In. (mm)5/8 (15.88) Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.0Y 9.2/0.2 Unit Dimensions W: In. (mm)31-7/16 (798) D: In. (mm)9-1/8 (232) H: In. (mm)11-5/8 (295) Package Dimensions W: In. (mm)33-1/2 (850) D: In. (mm)12 (300) H: In. (mm)14 (350) Unit Weight Lbs. (kg)22 (10) Package Weight Lbs. (kg)26 (11.5) Refrigerant Type R410A Piping Gas Pipe Size O.D. (Flared)In. (mm)3/8 (9.52) Liquid Pipe Size O.D. (Flared)In. (mm)1/4 (6.35) Nominal Conditions 1Cooling (Indoor // Outdoor)°F 80 DB, 67 WB // 95 DB, 75 WB 2Heating at 47°F (Indoor // Outdoor)°F 70 DB, 60 WB // 47 DB, 43 WB Capacity varies based on the number of indoor units operating and the model of the MXZ unit. For reference to connected capacity charts, please refer MXZ Multi-Zone Outdoor Unit Operational Performance. Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. SPECIFICATIONS: MSZ-GL12NA Specifications are subject to change without notice.© 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Anti-Allergy Enzyme Filter □ MAC-408FT-E Backlit, Wall-mounted, Wireless Controller □ MHK1 Portable Central Controller □ MCCH1 Wired MA Controller □ PAR-33MAA1 Simple MA Controller □ PAC-YT53CRAU1 Touch MA Controller □ PAR-CT01MAU-SB1 Wired Remote Sensor □ PAC-SE41TS-E Lockdown Bracket for Wireless, Hand-held, Remote Controller □ RCMKP1CB Wireless Temperature and Humidity Sensor □ PAC-USWHS003-TH-1 Outside Air Sensor for MHK1 □ MOS1 System Control Interface □ MAC-333IF-E2 Wireless Interface □ PAC-USWHS002-WF-1 Thermostat Interface □ PAC-US444CN-1 kumo station®□ PAC-WHS01HC-E USNAP Interface □ PAC-WHS01UP-E IT Extender □ PAC-WHS01IE-E BACnet® and Modbus Interface □ PAC-UKPRC001-CN-1 External Fan / Heater Control Relay Adapter □ CN24RELAY-KIT-CM3 Blue Diamond Sensor Extension Cable—15 Ft.□ C13-103 Blue Diamond Alarm Extension Cable—6.5 Ft.□ C13-192 Blue Diamond MultiTank—collection tank for use with multiple pumps □ C21-014 Blue Diamond Rubber Foot Pads □ F10-010 Mini Condensate Pump—230V application □ SI30-230 MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor □ X87-835 - 110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (110V) up to 48,000 Btu/h [recommended] □ X87-711 - 110V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) up to 48,000 Btu/h [recommended] □ X87-721 - 208/230V MicroBlue Blue Diamond Mini Condensate Pump (110/208/230V) up to 18,000 Btu/h □ X85-003 Fascia Kit for MicroBlue Pump – mounts the MicroBlue and sensor directly beneath the indoor unit □ T18-016 Drain Pan Level Sensor (Control for indoor unit shut off to prevent drain pan overflow)□ DPLS2 3 Pole Disconnect Switch (30A/600VUL) [fits 2"X4" utility] - Black □ TAZ-MS303 3 Pole Disconnect Switch (30A/600VUL) [fits 2"X4" utility] - White □ TAZ-MS303W 1/4" x 3/8" x 15' / 1/2" Lineset (Twin-Tube Insulation)□ MLS143812T-15 1/4" x 3/8" x 30' / 1/2" Lineset (Twin-Tube Insulation)□ MLS143812T-30 1/4" x 3/8" x 50' / 1/2" Lineset (Twin-Tube Insulation)□ MLS143812T-50 1/4" x 3/8" x 65' / 1/2" Lineset (Twin-Tube Insulation)□ MLS143812T-65 1 Requires MAC-333IF-E 2 Allows M-Series indoor units to connect to an MA controller ACCESSORIES: MSZ-GL12NA Specifications are subject to change without notice.© 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Unit: inch PipingInsulation ø1 - 3/8 O.D Liquid line ø1/4 19 - 11/16 (Flared connection ø1/4) Gas line ø3/8 16 - 15/16 (Flared connection: ø3/8 (GL06/09/12NA), ø1/2 (GL15NA)) Drain hose Insulation ø1-1/8 O.D Connected part ø5/8 O.D FORM# MSZ-GL12NA FOR MXZ-C MULTI-ZONE HEAT-PUMP SYSTEMS - 201808Ver2 1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com DIMENSIONS: MSZ-GL12NA Specifications are subject to change without notice.© 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Job Name: System Reference:Date: MODEL: XXXXXXXMODEL: MHK2 kumo touch™ MRCH2 REMOTE CONTROLLER SPECIFICATIONS • Touch panel, Backlit, easy-to-read display • Used RedLINK™ 3.0 wireless technology -Not compatible with MHK1, MOS1, and MCCH1 RedLINK 2.0 wireless technology environment. • User functions allow user to set: -On/Off -Operation modes cool, heat, drying, fan -Set temperature (separate dual set points for heat and cool) -Fan speed setting -Airflow direction • Set temperature range limits (dependent on the system connected): -Cooling from 50° to 99° F -Heating from 40° to 90° F -Auto from 50° to 90° F with dual temperature setting • MHK2 Scheduling options: -No Schedule -MO-SU = Every day the same -MO-FR, SA, SU = 5-1-1 schedule -MO-FR, SA-SU = 5-2 schedule -Each Day = Every day individual -Allow kumo cloud to be schedule holder • Hold function • Temporary or Permanent schedule override • Lockout: -On -Off -Mode -Fan Speed -Set point -Vane Direction • Day/Time display with a 12 or 24-hour clock • Supports both Fahrenheit and Celsius • RedLINK™ Wireless Connection Status • Filter sign display • Diagnostics: Displays and records error codes • Adjustable auto mode deadband • Space temperature offset adjustment • Space humidity offset adjustment • Hide (on screen only) -Indoor temperature -Indoor humidity • Temperature Sensing Source -MHK2 -Indoor Unit -RedLINK Wireless Indoor Air Sensor (IAS) -Average of MHK2 and RedLINK Wireless Indoor Air Sensor (IAS) • Indoor Humidity Source -MHK2 -RedLINK Wireless Indoor Air Sensor (IAS) -Average of MHK2 and RedLINK Wireless Indoor Air Sensor (IAS) • Improved indoor unit function code list -Indoor unit type -Expanded to 28 indoor unit codes • Reset to factory default • Uses two “AA” alkaline batteries (included) • Dimensions: 4-5/64” x 4-5/64” x 1-1/16” (104 x 104 x 27 mm) • Operating Ambient Temperature: 32° to 120° F (0° to 48.9° C) • Operating Relative Humidity: 5% to 90% MIFH2 WIRELESS RECEIVER SPECIFICATIONS: • Included in MHK2 Kit • Mounts next to or near indoor units to allow MRCH2 Remote Controller operation • Connects to indoor unit control board with MRC2 Cable • Dimensions: 3-3/32” H x 1-3/4” W x 39/64” D (74.8 x 44.4 x 15.4 mm) • Operating Ambient Temperature: -40° to 165° F (-40° to 73.9° C) • Operating Relative Humidity: 5% to 95% MRC2 CABLE • Included in MHK2 Kit in the MIFH2 box • Connects MIFH2 Wireless Receiver to the CN105 connector on indoor unit control board • Length: 39-23/64" (1 m) MRCH2 MIFH2 MRC2 Specifications are subject to change without notice. 1340 Satellite Boulevard. Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. M_Submittal_MHK2 kumo touch 03-2020 MODEL: MHK2 kumo touch™ kumo cloud & MHK2 • kumo cloud and MHK2 can work together on the same indoor unit with the following devices: -Wireless Interface 2 ◦PAC-USWHS002-WF-2 ◦Wireless Interface 2 has an additional CN105 connector on it -MHK2 kit • Compatibility with indoor units: -All CITY MULTI® -All P-Series -All M-series Accessories Wireless Interface 2 (PAC-USWHS002-WF-2) CN105 IT Extender (PAC-WHS01E-E) RedLINK 3.0 Wireless Indoor Air Sensor -Not sold by Mitsubishi Electric Trane HVAC LLC -Honeywell (C7189R2002-2/U) Wireless Interface 2 WiFi MRCH2 MRC2 MIFH2 To CN105 on Indoor Unit control board Job Name: System Reference:Date: Indoor Unit: MSZ-GL09NA Wireless Remote Controller GENERAL FEATURES •Slim wall-mounted indoor units provide zone comfort control • The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns • Multiple fan speed options: Quiet, Low, Medium, High, Super-high, Auto • Multiple control options available: - Hand-held Remote Controller (provided with unit) - kumo cloud® smart device app for remote access - Third-party interface options - Wired or wireless controllers • Hot-Start Technology: no cold air rush at equipment startup or when restarting after Defrost Cycle • Quiet operation • Smart Set: recalls a preferred preset temperature setting at the touch of a button SUBMITTAL DATA: MSZ-GL09NA 9,000 BTU/H WALL-MOUNTED INDOOR UNIT FOR MXZ-C MULTI-ZONE HEAT PUMP SYSTEMS Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. M-SERIES Cooling Capacity1, 3 BTU/H 9,000 Heating Capacity2, 3 BTU/H 10,900 Electrical Voltage, Phase, Frequency 208/230V, 1 phase, 60Hz Guaranteed Voltage Range V AC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 V AC 208 / 230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating (SCCR)5 MCA A 1 Blower Motor Full Load Amperage A 0.76 Blower Motor Output W 30 Airflow Rate at Cooling, Dry CFM 399-321-237-170-145 Airflow Rate at Cooling, Wet CFM 364-286-201-134-109 Airflow Rate at Heating, Dry CFM 406-321-237-170-145 Sound Pressure Level (Cooling)dB(A)43-37-30-22-19 Sound Pressure Level (Heating)dB(A)43-37-30-22-19 Drain Pipe Size In. (mm)5/8 (15.88) Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.0Y 9.2/0.2 Unit Dimensions W: In. (mm)31-7/16 (798) D: In. (mm)9-1/8 (232) H: In. (mm)11-5/8 (295) Package Dimensions W: In. (mm)33-1/2 (850) D: In. (mm)12 (300) H: In. (mm)14 (350) Unit Weight Lbs. (kg)22 (10) Package Weight Lbs. (kg)26 (11.5) Refrigerant Type R410A Piping Gas Pipe Size O.D. (Flared)In. (mm)3/8 (9.52) Liquid Pipe Size O.D. (Flared)In. (mm)1/4 (6.35) Notes: Nominal Conditions 1Cooling (Indoor // Outdoor)°F 80 DB, 67 WB // 95 DB, 75 WB 2Heating at 47°F (Indoor // Outdoor)°F 70 DB, 60 WB // 47 DB, 43 WB 3Capacity varies based on the number of indoor units operating and the model of the Multi-zone Outdoor Unit. For reference to connected capacity charts, please refer Multi-zone Outdoor Unit Operational Performance. SPECIFICATIONS: MSZ-GL09NA Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Anti-allergy Enzyme Filter □ MAC-408FT-E kumo touch™ RedLINK™ Wireless Controller □ MHK2 Deluxe MA Remote Controller1 □ PAR-40MAAU Simple MA Controller1 □ PAC-YT53CRAU-J Touch MA Controller1 □ PAR-CT01MAU-SB Wired Remote Sensor □ M21-EAA-307 Wireless Temperature and Humidity Sensor □ PAC-USWHS003-TH-1 System Control Interface2 □ MAC-334IF-E Wireless Interface 2 □ PAC-USWHS002-WF-2 Thermostat Interface □ PAC-US444CN-1 kumo station®□ PAC-WHS01HC-E USNAP Interface □ PAC-WHS01UP-E IT Extender □ PAC-WHS01IE-E BACnet® and MODBUS® Interface □ PAC-UKPRC001-CN-1 Lockdown Bracket for Hand-held Remote Controllers □ RCMKP1CB Blue Diamond Sensor Extension Cable —15 Ft.□ C13-103 Blue Diamond Alarm Extension Cable —6.5 Ft.□ C13-192 Blue Diamond MultiTank —collection tank for use with multiple pumps □ C21-014 Blue Diamond Rubber Foot Pads □ F10-010 Mini Condensate Pump —230 volt application □ SI30-230 MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor □ X87-835 - 110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (110V) up to 48,000 BTU/ H[recommended] □ X87-711 - 110V Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended]□ X87-721 - 208/230V MicroBlue Blue Diamond Mini Condensate Pump (110/208/230V) up to 18,000 BTU/H □ X85-003 Fascia Kit for MicroBlue Pump – mounts the MicroBlue and sensor directly beneath the indoor unit □ T18-016 Drain Pan Level Sensor □ SS610E (30A/600V/UL) [fits 2" X 4" utility box] - Black □ TAZ-MS303 (30A/600V/UL) [fits 2" X 4" utility box] - White □ TAZ-MS303W 1 Requires MAC-334IF-E 2 Allows indoor units to connect to an MA Controller ACCESSORIES: MSZ-GL09NA Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Unit: inch PipingInsulation ø1 - 3/8 O.D Liquid line ø1/4 19 - 11/16 (Flared connection ø1/4) Gas line ø3/8 16 - 15/16 (Flared connection: ø3/8 (06/09/12 KBTU/H), ø1/2 (15 KBTU/H) Drain hose Insulation ø1-1/8 O.D Connected part ø5/8 O.D FORM# MSZ-GL09NA FOR MXZ-C MULTI-ZONE HEAT PUMP SYSTEMS - 202003 1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com DIMENSIONS: MSZ-GL09NA Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Job Name: System Reference:Date: Indoor Unit: MSZ-GL09NA Outdoor Unit: MUZ-GL09NA-U1 MUZ-GL09NA-U2 MUZ-GL09NA-U8 Wireless Remote Controller GENERAL FEATURES • Slim wall-mounted indoor units provide zone comfort control • The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns • INVERTER-driven compressor and LEV provide high efficiency and comfort while using only the energy needed to maintain maximum performance • Multiple fan speed options: Quiet, Low, Medium, High, Super-high, Auto • Multiple control options available: - Hand-held Remote Controller (provided with unit) - kumo cloud® smart device app for remote access - Third-party interface options - Wired or wireless controllers • Quiet operation • Smart Set: recalls a preferred preset temperature setting at the touch of a button • Blue Fin anti-corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life SUBMITTAL DATA: MSZ-GL09NA & MUZ-GL09NA 9,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM Specifications are subject to change without notice.© 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. M-SERIES Cooling1 Maximum Capacity Btu/h 12,200 Rated Capacity Btu/h 9,000 Minimum Capacity Btu/h 3,600 Maximum Power Input W 1,050 Rated Power Input W 585 Moisture Removal Pints/h 1.5 Sensible Heat Factor 0.82 Power Factor %-U1/2: 86 / 86 -U8: 92 / 92 Heating at 47°F2 Maximum Capacity Btu/h -U1/2: 15,900 -U8: 14,100 Rated Capacity Btu/h 10,900 Minimum Capacity Btu/h 4,500 Maximum Power Input W -U1/2: 1,250 -U8: 1,070 Rated Power Input W 720 Power Factor %-U1/2: 90 / 90 -U8: 95 / 95 Heating at 17°F3 Maximum Capacity Btu/h -U1/2: 10,900 -U8: 9,400 Rated Capacity Btu/h -U1/2: 6,700 -U8: 7,000 Maximum Power Input W -U1/2: 1,060 -U8: 790 Rated Power Input W 630 Heating at 5°F4 Maximum Capacity Btu/h 8,170 Maximum Power Input W 850 Heating at -4°F5 Maximum Capacity Btu/h 6,860 Efficiency SEER 24.6 EER1 15.4 HSPF (IV)12.8 COP at 47°F2 4.44 COP at 17°F in Maximum Capacity3 2.82 COP at 5°F in Maximum Capacity4 2.82 ENERGY STAR® Certified (ENERGY STAR products are third-party certified by an EPA-recognized Certification Body.) YES Electrical Voltage, Phase, Frequency 208/230V, 1 phase, 60Hz Guaranteed Voltage Range V AC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 V AC 208 / 230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Voltage: Indoor - Remote Controller Wireless Type Recommended Fuse/Breaker Size A 15 Recommended Wire Size (Indoor - Outdoor)AWG 14 Indoor Unit MCA A 1 MOCP A 15 Blower Motor Full Load Amperage A 0.76 Blower Motor Output W 30 Airflow Rate at Cooling, Dry CFM 399-321-237-170-145 SPECIFICATIONS: MSZ-GL09NA & MUZ-GL09NA Specifications are subject to change without notice.© 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Airflow Rate at Cooling, Wet CFM 364-286-201-134-109 Airflow Rate at Heating, Dry CFM 406-321-237-170-145 Sound Pressure Level (Cooling)dB(A)43-37-30-22-19 Sound Pressure Level (Heating)dB(A)43-37-30-22-19 Drain Pipe Size In. (mm)5/8 (15.88) Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.0Y 9.2/0.2 Unit Dimensions W: In. (mm)31-7/16 (798) D: In. (mm)9-1/8 (232) H: In. (mm)11-5/8 (295) Package Dimensions W: In. (mm)33-1/2 (850) D: In. (mm)12 (300) H: In. (mm)14 (350) Unit Weight Lbs. (kg)22 (10) Package Weight Lbs. (kg)26 (11.5) Indoor Unit Operating Temperature Range Cooling Intake Air Temp (Maximum / Minimum)*°F 90 DB, 73 WB / 67 DB, 57 WB Heating Intake Air Temp (Maximum / Minimum)°F 80 DB / 70 DB Outdoor Unit MCA A 9 MOCP A 15 Fan Motor Full Load Amperage A 0.5 Fan Motor Output W 55 Airflow Rate CFM 1,229 / 1,172 Refrigerant Control LEV Defrost Method Reverse cycle Heat Exchanger Type Plate fin coil Sound Pressure Level, Cooling1 dB(A)48 Sound Pressure Level, Heating2 dB(A)50 Compressor Type DC INVERTER-driven Compressor Model -U1: KNB073FRVMC -U2: KNB073FRXMC -U8: SNB092FQANT Compressor Rated Load Amps A 6.7 Compressor Locked Rotor Amps A 7.7 Compressor Oil Type // Charge oz.-U1/2: FV50S //9.1 -U8: FY50S //11.8 External Finish Color Munsell 3Y 7.8/1/1 Base Pan Heater Optional Unit Dimensions W: In. (mm)31-1/2 (800) D: In. (mm)11-1/4 (285) H: In. (mm)21-5/8 (550) Package Dimensions W: In. (mm)37 (940) D: In. (mm)14-15/16 (380) SPECIFICATIONS: MSZ-GL09NA & MUZ-GL09NA Specifications are subject to change without notice.© 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. H: In. (mm)24-13/16 (630) Unit Weight Lbs. (kg)81 (37) Package Weight Lbs. (kg)88 (40) Outdoor Unit Operating Temperature Range Cooling Air Temp (Maximum / Minimum)*°F 115 / 14 Cooling Thermal Lock-out / Re-start Temperatures**°F -1 / 3 Heating Air Temp (Maximum / Minimum)°F 75 / -4 Heating Thermal Lock-out / Re-start Temperatures**°F -9 / -4 Refrigerant Type R410A Charge Lbs, oz -U1/2: 2, 5 -U8: 2, 9 Piping Gas Pipe Size O.D. (Flared)In. (mm)3/8 (9.52) Liquid Pipe Size O.D. (Flared)In. (mm)1/4 (6.35) Maximum Piping Length Ft. (m)65 (20) Maximum Height Difference Ft. (m)40 (12) Maximum Number of Bends 10 Notes AHRI Rated Conditions (Rated data is determined at a fixed compressor speed) 1Cooling (Indoor // Outdoor)°F 80 DB, 67 WB // 95 DB, 75 WB 2Heating at 47°F (Indoor // Outdoor)°F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor)°F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor)°F 70 DB, 60 WB // 5 DB, 4 WB 5Heating at -4°F (Indoor // Outdoor)°F 70 DB, 60 WB // -4 DB, -5 WB *Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SPECIFICATIONS: MSZ-GL09NA & MUZ-GL09NA Specifications are subject to change without notice.© 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Anti-allergy Enzyme Filter □ MAC-408FT-E Backlit, Wall-mounted, Wireless Controller □ MHK1 Portable Central Controller □ MCCH1 Wired MA Controller1 □ PAR-33MAA Simple MA Controller1 □ PAC-YT53CRAU Touch MA Controller1 □ PAR-CT01MAU-SB Wired Remote Sensor □ M21-EAA-307 Wireless Temperature and Humidity Sensor □ PAC-USWHS003-TH-1 Outside Air Sensor for MHK1 □ MOS1 System Control Interface2 □ MAC-333IF-E Wireless Interface □ PAC-USWHS002-WF-1 Thermostat Interface □ PAC-US444CN-1 kumo station®□ PAC-WHS01HC-E USNAP Interface □ PAC-WHS01UP-E IT Extender □ PAC-WHS01IE-E BACnet® and MODBUS® Interface □ PAC-UKPRC001-CN-1 Lockdown Bracket for Hand-held Remote Controllers □ RCMKP1CB Blue Diamond Sensor Extension Cable —15 Ft.□ C13-103 Blue Diamond Alarm Extension Cable —6.5 Ft.□ C13-192 Blue Diamond MultiTank —collection tank for use with multiple pumps □ C21-014 Blue Diamond Rubber Foot Pads □ F10-010 Mini Condensate Pump —230 volt application □ SI30-230 MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor □ X87-835 - 110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (110V) up to 48,000 Btu/h [recommended] □ X87-711 - 110V Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended]□ X87-721 - 208/230V MicroBlue Blue Diamond Mini Condensate Pump (110/208/230V) up to 18,000 Btu/h □ X85-003 Fascia Kit for MicroBlue Pump – mounts the MicroBlue and sensor directly beneath the indoor unit □ T18-016 Drain Pan Level Sensor □ DPLS2 (30A/600V/UL) [fits 2" X 4" utility box] - Black □ TAZ-MS303 (30A/600V/UL) [fits 2" X 4" utility box] - White □ TAZ-MS303W 1 Requires MAC-333IF-E 2 Allows indoor units to connect to an MA Controller ACCESSORIES: MSZ-GL09NA Specifications are subject to change without notice.© 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Outlet Guide □ MAC-881SG Drain Socket □ MAC-860DS Optional Defrost Heater □ MAC-640BH-U Hail Guard □ HG-B4 Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic □ DSD-400P Condensing Unit Mounting Pad 16" x 36" x 3"□ ULTRILITE1 Outdoor Unit Stand —12" High □ QSMS1201M Outdoor Unit Stand —18" High □ QSMS1801M Outdoor Unit Stand —24" High □ QSMS2401M Heavy Duty Wall Mounting Bracket— Coated Steel □ QSWB2000M-1 Heavy Duty Wall Mounting Bracket —316 Series Stainless Steel □ QSWBSS 15' x 1/4" x 15' / 3/8" Lineset (Twin-Tube Insulation)□ MLS143812T-15 30' x 1/4" x 30' / 3/8" Lineset (Twin-Tube Insulation)□ MLS143812T-30 50' x 1/4" x 50' / 3/8" Lineset (Twin-Tube Insulation)□ MLS143812T-50 65' x 1/4" x 65' / 3/8" Lineset (Twin-Tube Insulation)□ MLS143812T-65 ACCESSORIES: MUZ-GL09NA Specifications are subject to change without notice.© 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Unit: inch PipingInsulation ø1 - 3/8 O.D Liquid line ø1/4 19 - 11/16 (Flared connection ø1/4) Gas line ø3/8 16 - 15/16 (Flared connection: ø3/8 (GL06/09/12NA), ø1/2 (GL15NA)) Drain hose Insulation ø1-1/8 O.D Connected part ø5/8 O.D DIMENSIONS: MSZ-GL09NA Specifications are subject to change without notice.© 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Unit: inch clear *1*1 4 in. or more when front and sides of the unit are clear *2 When any 2 sides of left, right and rear of the unit are clear holes (09/12/15 Btu/h) REQUIRED SPACE Liquid refrigerant pipe joint Refrigerant pipe (flared) Ø 1/4 Gas refrigerant pipe joint Refrigerant pipe (flared) Ø 3/8 (09/12 kBtu/h) Ø 1/2 (15 kBtu/h) 4 in. or m or e 14 i n . o r m o r e 8 in. o r m o r e * 2 4 in . o r m o r e FORM# MSZ-GL09NA / MUZ-GL09NA - 201903 , , DIMENSIONS: MUZ-GL09NA Specifications are subject to change without notice.© 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Job Name: System Reference:Date: Indoor Unit: MSZ-GL12NA Outdoor Unit: □ MUZ-GL12NA-U1 □ MUZ-GL12NA-U2 Wireless Remote Controller GENERAL FEATURES •Slim wall-mounted indoor units provide zone comfort control • The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns • INVERTER-driven compressor and LEV provide high efficiency and comfort while using only the energy needed to maintain maximum performance • Multiple fan speed options: Quiet, Low, Medium, High, Super-high, Auto • Multiple control options available: - Hand-held Remote Controller (provided with unit) - kumo cloud® smart device app for remote access - Third-party interface options - Wired or wireless controllers • Quiet operation • Smart Set: recalls a preferred preset temperature setting at the touch of a button • Blue Fin anti-corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life SUBMITTAL DATA: MSZ-GL12NA & MUZ-GL12NA 12,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. M-SERIES Cooling1 Maximum Capacity BTU/H 13,600 Rated Capacity BTU/H 12,000 Minimum Capacity BTU/H 1,500 Maximum Power Input W 1,300 Rated Power Input W 920 Moisture Removal Pints/h 2.5 Sensible Heat Factor 0.77 Power Factor %95 / 95 Heating at 47°F2 Maximum Capacity BTU/H 18,100 Rated Capacity BTU/H 14,400 Minimum Capacity BTU/H 2,000 Maximum Power Input W 1,620 Rated Power Input W 1,100 Power Factor %96 / 96 Heating at 17°F3 Maximum Capacity BTU/H 12,000 Rated Capacity BTU/H 9,200 Maximum Power Input W 1,240 Rated Power Input W 870 Heating at 5°F4 Maximum Capacity BTU/H 9,790 Maximum Power Input W 1,020 Heating at -4°F5 Maximum Capacity BTU/H 7,920 Efficiency SEER 23.1 EER1 13.0 HSPF (IV)12.5 COP at 47°F2 3.84 COP at 17°F in Maximum Capacity3 2.84 COP at 5°F in Maximum Capacity4 2.81 ENERGY STAR® certified units (ENERGY STAR products are third-party certified by an EPA-recognized Certification Body.) YES Electrical Voltage, Phase, Frequency 208/230V, 1 phase, 60Hz Guaranteed Voltage Range V AC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 V AC 208 / 230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating (SCCR)kA 5 Recommended Fuse/Breaker Size (Outdoor)A 15 Recommended Wire Size (Indoor - Outdoor)AWG 14 Indoor Unit MCA A 1 MOCP A 15 Blower Motor Full Load Amperage A 0.76 Blower Motor Output W 30 Airflow Rate at Cooling, Dry CFM 399-321-237-170-145 SPECIFICATIONS: MSZ-GL12NA & MUZ-GL12NA Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Airflow Rate at Cooling, Wet CFM 364-286-201-134-109 Airflow Rate at Heating, Dry CFM 406-321-237-170-145 Sound Pressure Level (Cooling)dB(A)45-37-30-22-19 Sound Pressure Level (Heating)dB(A)43-37-30-22-19 Drain Pipe Size In. (mm)5/8 (15.88) Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.0Y 9.2/0.2 Unit Dimensions W: In. (mm)31-7/16 (798) D: In. (mm)9-1/8 (232) H: In. (mm)11-5/8 (295) Package Dimensions W: In. (mm)33-1/2 (850) D: In. (mm)12 (300) H: In. (mm)14 (350) Unit Weight Lbs. (kg)22 (10) Package Weight Lbs. (kg)26 (11.5) Indoor Unit Operating Temperature Range Cooling Intake Air Temp (Maximum / Minimum)*°F 90 DB, 73 WB / 67 DB, 57 WB Heating Intake Air Temp (Maximum / Minimum)°F 80 DB / 70 DB Outdoor Unit MCA A 9 MOCP A 15 Fan Motor Full Load Amperage A 0.5 Fan Motor Output W 55 Airflow Rate CFM 1,229 / 1,172 Refrigerant Control LEV Defrost Method Reverse cycle Heat Exchanger Type Plate fin coil Sound Pressure Level, Cooling1 dB(A)49 Sound Pressure Level, Heating2 dB(A)51 Compressor Type DC INVERTER-driven Compressor Model SNB092FQAMT Compressor Rated Load Amps A 6.6 Compressor Locked Rotor Amps A 8.2 Compressor Oil Type // Charge oz.FV50S // 11.8 External Finish Color Munsell 3Y 7.8/1/1 Base Pan Heater Optional Unit Dimensions W: In. (mm)31-1/3 (800) D: In. (mm)11-1/5 (285) H: In. (mm)21-5/9 (550) Package Dimensions W: In. (mm)37 (940) D: In. (mm)14-15/16 (380) H: In. (mm)24-13/16 (630) Unit Weight Lbs. (kg)81 (37) SPECIFICATIONS: MSZ-GL12NA & MUZ-GL12NA Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Package Weight Lbs. (kg)89 (40) Outdoor Unit Operating Temperature Range Cooling Air Temp (Maximum / Minimum)*°F 115 / 14 Cooling Thermal Lock-out / Re-start Temperatures**°F -1 / 3 Heating Air Temp (Maximum / Minimum)°F 75 / -4 Heating Thermal Lock-out / Re-start Temperatures**°F -9 / -4 Refrigerant Type R410A Charge Lbs, oz 2, 9 Piping Gas Pipe Size O.D. (Flared)In. (mm)3/8 (9.52) Liquid Pipe Size O.D. (Flared)In. (mm)1/4 (6.35) Maximum Piping Length Ft. (m)65 (20) Maximum Height Difference Ft. (m)40 (12) Maximum Number of Bends 10 Notes AHRI Rated Conditions (Rated data is determined at a fixed compressor speed) 1Cooling (Indoor // Outdoor)°F 80 DB, 67 WB // 95 DB, 75 WB 2Heating at 47°F (Indoor // Outdoor)°F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor)°F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor)°F 70 DB, 60 WB // 5 DB, 4 WB 5Heating at -4°F (Indoor // Outdoor)°F 70 DB, 60 WB // -4 DB, -5 WB *Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SPECIFICATIONS: MSZ-GL12NA & MUZ-GL12NA Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Anti-allergy Enzyme Filter □ MAC-408FT-E kumo touch™ RedLINK™ Wireless Controller □ MHK2 Deluxe MA Remote Controller1 □ PAR-40MAAU Simple MA Controller1 □ PAC-YT53CRAU-J Touch MA Controller1 □ PAR-CT01MAU-SB Wired Remote Sensor □ M21-EAA-307 Wireless Temperature and Humidity Sensor □ PAC-USWHS003-TH-1 System Control Interface2 □ MAC-334IF-E Wireless Interface 2 □ PAC-USWHS002-WF-2 Thermostat Interface □ PAC-US444CN-1 kumo station®□ PAC-WHS01HC-E USNAP Interface □ PAC-WHS01UP-E IT Extender □ PAC-WHS01IE-E BACnet® and MODBUS® Interface □ PAC-UKPRC001-CN-1 Lockdown Bracket for Hand-held Remote Controllers □ RCMKP1CB Blue Diamond Sensor Extension Cable —15 Ft.□ C13-103 Blue Diamond Alarm Extension Cable —6.5 Ft.□ C13-192 Blue Diamond MultiTank —collection tank for use with multiple pumps □ C21-014 Blue Diamond Rubber Foot Pads □ F10-010 Mini Condensate Pump —230 volt application □ SI30-230 MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor □ X87-835 - 110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (110V) up to 48,000 BTU/ H[recommended] □ X87-711 - 110V Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended]□ X87-721 - 208/230V MicroBlue Blue Diamond Mini Condensate Pump (110/208/230V) up to 18,000 BTU/H □ X85-003 Fascia Kit for MicroBlue Pump – mounts the MicroBlue and sensor directly beneath the indoor unit □ T18-016 Drain Pan Level Sensor □ SS610E (30A/600V/UL) [fits 2" X 4" utility box] - Black □ TAZ-MS303 (30A/600V/UL) [fits 2" X 4" utility box] - White □ TAZ-MS303W 1 Requires MAC-334IF-E 2 Allows indoor units to connect to an MA Controller ACCESSORIES: MSZ-GL12NA Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Outlet Guide □ MAC-881SG Drain Socket □ MAC-860DS Optional Defrost Heater □ MAC-640BH-U Hail Guard □ HG-B4 Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic □ DSD-400P Condensing Unit Mounting Pad 16" x 36" x 3"□ ULTRILITE1 Outdoor Unit Stand —12" High □ QSMS1201M Outdoor Unit Stand —18" High □ QSMS1801M Outdoor Unit Stand —24" High □ QSMS2401M Heavy Duty Wall Mounting Bracket— Coated Steel □ QSWB2000M-1 Heavy Duty Wall Mounting Bracket —316 Series Stainless Steel □ QSWBSS 15' x 1/4" x 15' / 3/8" Lineset (Twin-Tube Insulation)□ MLS143812T-15 30' x 1/4" x 30' / 3/8" Lineset (Twin-Tube Insulation)□ MLS143812T-30 50' x 1/4" x 50' / 3/8" Lineset (Twin-Tube Insulation)□ MLS143812T-50 65' x 1/4" x 65' / 3/8" Lineset (Twin-Tube Insulation)□ MLS143812T-65 ACCESSORIES: MUZ-GL12NA Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Unit: inch PipingInsulation ø1 - 3/8 O.D Liquid line ø1/4 19 - 11/16 (Flared connection ø1/4) Gas line ø3/8 16 - 15/16 (Flared connection: ø3/8 (06/09/12 KBTU/H), ø1/2 (15 KBTU/H) Drain hose Insulation ø1-1/8 O.D Connected part ø5/8 O.D DIMENSIONS: MSZ-GL12NA Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Unit: inch clear *1*1 4 in. or more when front and sides of the unit are clear *2 When any 2 sides of left, right and rear of the unit are clear holes (09/12/15 Btu/h) REQUIRED SPACE Liquid refrigerant pipe joint Refrigerant pipe (flared) Ø 1/4 Gas refrigerant pipe joint Refrigerant pipe (flared) Ø 3/8 (09/12 KBTU/H) Ø 1/2 (15 KBTU/H) 4 in. or m or e 14 i n . o r m o r e 8 in. o r m o r e * 2 4 in . o r m o r e FORM# MSZ-GL12NA / MUZ-GL12NA - 202003 1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com DIMENSIONS: MUZ-GL12NA Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Job Name: System Reference:Date: Indoor Unit: MSZ-GL18NA Outdoor Unit: MUZ-GL18NA Wireless Remote Controller GENERAL FEATURES • Slim wall-mounted indoor units provide zone comfort control •The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns • INVERTER-driven compressor and LEV provide high efficiency and comfort while using only the energy needed to maintain maximum performance • Multiple fan speed options: Quiet, Low, Medium, High, Super-high, Auto • Multiple control options available: - Hand-held Remote Controller (provided with unit) - kumo cloud® smart device app for remote access - Third-party interface options - Wired or wireless controllers • Quiet operation • Smart Set: recalls a preferred preset temperature setting at the touch of a button • Blue Fin anti-corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life SUBMITTAL DATA: MSZ-GL18NA & MUZ-GL18NA 18,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. M-SERIES Cooling1 Maximum Capacity BTU/H 22,000 Rated Capacity BTU/H 18,000 Minimum Capacity BTU/H 5,800 Maximum Power Input W 2,105 Rated Power Input W 1,340 Moisture Removal Pints/h 2.1 Sensible Heat Factor 0.87 Power Factor %99 / 99 Heating at 47°F2 Maximum Capacity BTU/H 25,000 Rated Capacity BTU/H 21,600 Minimum Capacity BTU/H 5,400 Maximum Power Input W 2,455 Rated Power Input W 1,680 Power Factor %99 / 99 Heating at 17°F3 Maximum Capacity BTU/H 18,200 Rated Capacity BTU/H 13,800 Maximum Power Input W 2,105 Rated Power Input W 1,435 Heating at 5°F4 Maximum Capacity BTU/H 14,900 Maximum Power Input W 1,880 Heating at -4°F5 Maximum Capacity BTU/H 15,520 Efficiency SEER 20.5 EER1 13.4 HSPF (IV)11.2 COP at 47°F2 3.77 COP at 17°F in Maximum Capacity3 2.53 COP at 5°F in Maximum Capacity4 2.32 ENERGY STAR® certified units (ENERGY STAR products are third-party certified by an EPA-recognized Certification Body.) YES Electrical Voltage, Phase, Frequency 208/230V, 1 phase, 60Hz Guaranteed Voltage Range V AC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 V AC 208 / 230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating (SCCR)kA 5 Recommended Fuse/Breaker Size (Outdoor)A 15 Recommended Wire Size (Indoor - Outdoor)AWG 14 Indoor Unit MCA A 1 MOCP A 15 Blower Motor Full Load Amperage A 0.67 Blower Motor Output W 30 Airflow Rate at Cooling, Dry CFM 646-522-417-332-258 SPECIFICATIONS: MSZ-GL18NA & MUZ-GL18NA Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Airflow Rate at Cooling, Wet CFM 581-470-375-299-232 Airflow Rate at Heating, Dry CFM 646-565-469-385-297 Sound Pressure Level (Cooling)dB(A)49-44-38-33-28 Sound Pressure Level (Heating)dB(A)48-43-38-33-28 Drain Pipe Size In. (mm)5/8 (15.88) Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.0Y 9.2/0.2 Unit Dimensions W: In. (mm)36-5/16 (923) D: In. (mm)9-13/16 (250) H: In. (mm)12 (305) Package Dimensions W: In. (mm)39 (990) D: In. (mm)13 (330) H: In. (mm)15 (380) Unit Weight Lbs. (kg)28 (13) Package Weight Lbs. (kg)33 (15) Indoor Unit Operating Temperature Range Cooling Intake Air Temp (Maximum / Minimum)*°F 90 DB, 73 WB / 67 DB, 57 WB Heating Intake Air Temp (Maximum / Minimum)°F 80 DB / 70 DB Outdoor Unit MCA A 14 MOCP A 15 Fan Motor Full Load Amperage A 0.93 Fan Motor Output W 77 Airflow Rate CFM 1,691 / 1,691 Refrigerant Control LEV Defrost Method Reverse cycle Heat Exchanger Type Plate fin coil Sound Pressure Level, Cooling1 dB(A)54 Sound Pressure Level, Heating2 dB(A)55 Compressor Type DC INVERTER-driven Compressor Model SNB130FQBMT Compressor Rated Load Amps A 10.0 Compressor Locked Rotor Amps A 12.5 Compressor Oil Type // Charge oz.FV50S // 11.8 External Finish Color Munsell 3Y 7.8/1/1 Base Pan Heater Optional Unit Dimensions W: In. (mm)33-1/16 (840) D: In. (mm)13 (330) H: In. (mm)34-5/8 [880] Package Dimensions W: In. (mm)38-9/16 (980) D: In. (mm)16-9/16 (420) H: In. (mm)39 (990) Unit Weight Lbs. (kg)121 (55) SPECIFICATIONS: MSZ-GL18NA & MUZ-GL18NA Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Package Weight Lbs. (kg)141 (64) Outdoor Unit Operating Temperature Range Cooling Air Temp (Maximum / Minimum)*°F 115 / 14 Cooling Thermal Lock-out / Re-start Temperatures**°F -1 / 3 Heating Air Temp (Maximum / Minimum)°F 75 / -4 Heating Thermal Lock-out / Re-start Temperatures**°F -9 / -4 Refrigerant Type R410A Charge Lbs, oz 3, 9 Piping Gas Pipe Size O.D. (Flared)In. (mm)1/2 (12.7) Liquid Pipe Size O.D. (Flared)In. (mm)1/4 (6.35) Maximum Piping Length Ft. (m)100 (30) Maximum Height Difference Ft. (m)50 (15) Maximum Number of Bends 10 Notes AHRI Rated Conditions (Rated data is determined at a fixed compressor speed) 1Cooling (Indoor // Outdoor)°F 80 DB, 67 WB // 95 DB, 75 WB 2Heating at 47°F (Indoor // Outdoor)°F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor)°F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor)°F 70 DB, 60 WB // 5 DB, 4 WB 5Heating at -4°F (Indoor // Outdoor)°F 70 DB, 60 WB // -4 DB, -5 WB *Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SPECIFICATIONS: MSZ-GL18NA & MUZ-GL18NA Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Anti-allergy Enzyme Filter □ MAC-408FT-E kumo touch™ RedLINK™ Wireless Controller □ MHK2 Deluxe MA Remote Controller1 □ PAR-40MAAU Simple MA Controller1 □ PAC-YT53CRAU-J Touch MA Controller1 □ PAR-CT01MAU-SB Wired Remote Sensor □ M21-EAA-307 Wireless Temperature and Humidity Sensor □ PAC-USWHS003-TH-1 System Control Interface2 □ MAC-334IF-E Wireless Interface 2 □ PAC-USWHS002-WF-2 Thermostat Interface □ PAC-US444CN-1 kumo station®□ PAC-WHS01HC-E USNAP Interface □ PAC-WHS01UP-E IT Extender □ PAC-WHS01IE-E BACnet® and MODBUS® Interface □ PAC-UKPRC001-CN-1 Lockdown Bracket for Hand-held Remote Controllers □ RCMKP1CB Blue Diamond Sensor Extension Cable —15 Ft.□ C13-103 Blue Diamond Alarm Extension Cable —6.5 Ft.□ C13-192 Blue Diamond MultiTank —collection tank for use with multiple pumps □ C21-014 Blue Diamond Rubber Foot Pads □ F10-010 Mini Condensate Pump —230 volt application □ SI30-230 MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor □ X87-835 - 110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (110V) up to 48,000 BTU/ H[recommended] □ X87-711 - 110V Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended]□ X87-721 - 208/230V MicroBlue Blue Diamond Mini Condensate Pump (110/208/230V) up to 18,000 BTU/H □ X85-003 Fascia Kit for MicroBlue Pump – mounts the MicroBlue and sensor directly beneath the indoor unit □ T18-016 Drain Pan Level Sensor □ SS610E (30A/600V/UL) [fits 2" X 4" utility box] - Black □ TAZ-MS303 (30A/600V/UL) [fits 2" X 4" utility box] - White □ TAZ-MS303W 1 Requires MAC-334IF-E 2 Allows indoor units to connect to an MA Controller ACCESSORIES: MSZ-GL18NA Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Outlet Guide □ MAC-886SG-E Drain Socket □ MAC-860DS Optional Defrost Heater □ MAC-642BH-U1 Hail Guard □ HG-A7 Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic □ DSD-400P Condensing Unit Mounting Pad 16" x 36" x 3"□ ULTRILITE1 Outdoor Unit Stand —12" High □ QSMS1201M Outdoor Unit Stand —18" High □ QSMS1801M Outdoor Unit Stand —24" High □ QSMS2401M Heavy Duty Wall Mounting Bracket— Coated Steel □ QSWB2000M-1 Heavy Duty Wall Mounting Bracket —316 Series Stainless Steel □ QSWBSS 15' x 1/4" x 15' / 1/2" Lineset (Twin-Tube Insulation)□ MLS141212T-15 30' x 1/4" x 30' / 1/2" Lineset (Twin-Tube Insulation)□ MLS141212T-30 50' x 1/4" x 50' / 1/2" Lineset (Twin-Tube Insulation)□ MLS141212T-50 65' x 1/4" x 65' / 1/2" Lineset (Twin-Tube Insulation)□ MLS141212T-65 100' x 1/4" x 100' / 1/2" Lineset (Twin-Tube Insulation)□ MLS141212T-100 ACCESSORIES: MUZ-GL18NA Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. A-39 Unit: inch PipingInsulation Ø2 O.D Liquid line Ø5/16 15-3/8 (Flared connection Ø1/4) Gas line Ø15/32 13-3/8 (Flared connection Ø1/2) Drain hose Insulation Ø1-1/8 Connected part Ø5/8 O.D 3/4 6-1/42-5/162-1/42-1/2 9-13/16 3/16 35-13/16 36-5/16 1/4 27-15/16 6-5/162-1/1612 2-9/16 2-13/162-1/22-9/16 3-11/16 2-1/169-7/1610-5/161/88-7/8 8-7/83-11/16 8-3/410-3/82-5/16 15-7/8 8-11/16 3-11/16 7/81×7/16 Oblong hole 7/16×13/16 Oblong holeInstallation plate Indoor unit Wall hole Ø3Air in Installation plate 8-1/16 15-3/161-5/88-11/163 1-11/162-9/16 2-9/164-1/2 5-3/41/4Air out Piping Drain hose3-15/16MSZ-GL24NA MSY-GL24NA DIMENSIONS: MSZ-GL18NA Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Unit: inch 16-7/16 1-9/16 1-5/8Drain hole 6-7/8 19-11/16132Air in Air in Air out 2-holes 13/32 13/1614-3/1633-1/16 4-5/16 3-3/16 34-5/817-25/32Service panel 3-29/326-1/27-11/16 3544Liquid refrigerant pipe joint Refrigerant pipe (flared) Ø 1/4 (18 kBtu/h) Refrigerant pipe (flared) Ø 3/8 (24 kBtu/h) Gas refrigerant pipe joint Refrigerant pipe (flared) Ø 1/2 (18 kBtu/h) Refrigerant pipe (flared) Ø 5/8 (24 kBtu/h) *1 20 in. or more when front and sides of the unit are clear 14 i n . o r m o r e 4 in . or m o r e REQUIRED SPACE Clear *14 in. o r m o r e 20 in. o r m o r e * 2 *2 When any 2 sides of left, right and rear of the unit are clear15-3/8FORM# MSZ-GL18NA / MUZ-GL18NA - 202003 1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com DIMENSIONS: MUZ-GL18NA Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Job Name: System Reference:Date: Indoor Unit: MSZ-GL24NA Wireless Remote Controller GENERAL FEATURES •Slim wall-mounted indoor units provide zone comfort control • The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns • Multiple fan speed options: Quiet, Low, Medium, High, Super-high, Auto • Multiple control options available: - Hand-held Remote Controller (provided with unit) - kumo cloud® smart device app for remote access - Third-party interface options - Wired or wireless controllers • Hot-Start Technology: no cold air rush at equipment startup or when restarting after Defrost Cycle • Quiet operation • Smart Set: recalls a preferred preset temperature setting at the touch of a button SUBMITTAL DATA: MSZ-GL24NA 24,000 BTU/H WALL-MOUNTED INDOOR UNIT FOR MXZ-C MULTI-ZONE HEAT PUMP SYSTEMS Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. M-SERIES Cooling Capacity1, 3 BTU/H 22,500 Heating Capacity2, 3 BTU/H 27,600 Electrical Voltage, Phase, Frequency 208/230V, 1 phase, 60Hz Guaranteed Voltage Range V AC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 V AC 208 / 230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating (SCCR)5 MCA A 1 Blower Motor Full Load Amperage A 0.76 Blower Motor Output W 56 Airflow Rate at Cooling, Dry CFM 738-628-544-469-388 Airflow Rate at Cooling, Wet CFM 661-562-487-420-347 Airflow Rate at Heating, Dry CFM 738-628-544-469-388 Sound Pressure Level (Cooling)dB(A)53-49-45-41-34 Sound Pressure Level (Heating)dB(A)52-49-45-41-32 Drain Pipe Size In. (mm)5/8 (15.88) Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.0Y 9.2/0.2 Unit Dimensions W: In. (mm)43-5/16 (1,100) D: In. (mm)9-3/8 (238) H: In. (mm)12-13/16 (325) Package Dimensions W: In. (mm)45-1/2 (1,160) D: In. (mm)12-3/4 (320) H: In. (mm)15-1/2 (390) Unit Weight Lbs. (kg)37 (17) Package Weight Lbs. (kg)37 (17) Refrigerant Type R410A Piping Gas Pipe Size O.D. (Flared)In. (mm)5/8 (15.88) Liquid Pipe Size O.D. (Flared)In. (mm)3/8 (9.52) Notes: Nominal Conditions 1Cooling (Indoor // Outdoor)°F 80 DB, 67 WB // 95 DB, 75 WB 2Heating at 47°F (Indoor // Outdoor)°F 70 DB, 60 WB // 47 DB, 43 WB 3Capacity varies based on the number of indoor units operating and the model of the Multi-zone Outdoor Unit. For reference to connected capacity charts, please refer Multi-zone Outdoor Unit Operational Performance. SPECIFICATIONS: MSZ-GL24NA Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Anti-allergy Enzyme Filter □ MAC-2310FT-E kumo touch™ RedLINK™ Wireless Controller □ MHK2 Deluxe MA Remote Controller1 □ PAR-40MAAU Simple MA Controller1 □ PAC-YT53CRAU-J Touch MA Controller1 □ PAR-CT01MAU-SB Wireless Temperature and Humidity Sensor □ PAC-USWHS003-TH-1 System Control Interface2 □ MAC-334IF-E Wireless Interface 2 □ PAC-USWHS002-WF-2 Thermostat Interface □ PAC-US444CN-1 kumo station®□ PAC-WHS01HC-E USNAP Interface □ PAC-WHS01UP-E IT Extender □ PAC-WHS01IE-E BACnet® and MODBUS® Interface □ PAC-UKPRC001-CN-1 Lockdown Bracket for Hand-held Remote Controllers □ RCMKP1CB Blue Diamond Sensor Extension Cable —15 Ft.□ C13-103 Blue Diamond Alarm Extension Cable —6.5 Ft.□ C13-192 Blue Diamond MultiTank —collection tank for use with multiple pumps □ C21-014 Blue Diamond Rubber Foot Pads □ F10-010 Mini Condensate Pump —230 volt application □ SI30-230 MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor □ X87-835 - 110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (110V) up to 48,000 BTU/ H[recommended] □ X87-711 - 110V Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended]□ X87-721 - 208/230V MicroBlue Blue Diamond Mini Condensate Pump (110/208/230V) up to 18,000 BTU/H □ X85-003 Fascia Kit for MicroBlue Pump – mounts the MicroBlue and sensor directly beneath the indoor unit □ T18-016 Drain Pan Level Sensor □ SS610E (30A/600V/UL) [fits 2" X 4" utility box] - Black □ TAZ-MS303 (30A/600V/UL) [fits 2" X 4" utility box] - White □ TAZ-MS303W 1 Requires MAC-334IF-E 2 Allows indoor units to connect to an MA Controller ACCESSORIES: MSZ-GL24NA Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Unit: inch FORM# MSZ-GL24NA FOR MXZ-C MULTI-ZONE HEAT PUMP SYSTEMS - 202003 1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com DIMENSIONS: MSZ-GL24NA Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US, LLC Job Name: System Reference:Date: SUBMITTAL DATA: MXZ-2C20NA2 1.5-TON MULTI-ZONE INVERTER HEAT-PUMP SYSTEM GENERAL FEATURES • Variable speed INVERTER-driven compressor • Energy Star® certified1 (non-ducted) • M-NET connection through outdoor unit • Quiet outdoor unit operation as low as 50 dB(A) • New Intelligent Power Module (IPM) for reduced power loss • Selectable thermal lockout/restart function • Optional base pan heater • High pressure switch for additional protection • Thermal differential of +/-1° F from setpoint M-Series 1 ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US, LLC SPECIFICATIONS: MXZ-2C20NA2 Model Number Outdoor Unit MXZ-2C20NA2 Indoor Unit Type Non-ducted Mix Ducted Cooling*1 Maximum Capacity Btu/h 20,000 20,000 20,000 Rated Capacity Btu/h 18,000 19,000 20,000 Minimum Capacity Btu/h 5,700 5,700 5,700 Maximum Power Input W 2,245 2,245 2,245 Rated Power Input W 1,417 1,709 2,000 Power Factor %98.7 99.3 99.9 Heating at 47° F*2 Maximum Capacity Btu/h 25,000 25,000 25,000 Rated Capacity Btu/h 22,000 22,000 22,000 Minimum Capacity Btu/h 7,400 7,400 7,400 Maximum Power Input W 2,455 2,455 2,455 Rated Power Input W 1,641 1,706 1,771 Power Factor %96.2 97.9 99.6 Heating at 17° F*3 Maximum Capacity Btu/h 15,500 15,000 14,500 Rated Capacity Btu/h 12,500 13,000 13,500 Maximum Power Input W 1,750 1,780 1,810 Rated Power Input W 1,300 1,325 1,350 Heating at 5° F*4 Maximum Capacity Btu/h 11,100 11,000 10,900 Maximum Power Input W 1,600 1,625 1,650 Efficiency SEER 20.00 18.00 16.00 EER *1 12.70 11.35 10.00 HSPF (IV)10.00 9.65 9.30 COP at 47° F*2 3.93 3.78 3.64 COP at 17° F*3 2.82 2.87 2.93 ENERGY STAR® Certified Yes No No Electrical Voltage, Phase, Frequency V AC 208 / 230V, 1-phase, 60 Hz Guaranteed Voltage Range V AC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 V AC 208V / 230 Voltage: Indoor - Outdoor, S2-S3 V AC 12-24 Voltage: Indoor - Remote Controller V AC 24 Recommended Fuse/Breaker Size A 20 Recommended Wire Size (Indoor-Outdoor)AWG AWG14 Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US, LLC SPECIFICATIONS: MXZ-2C20NA2 Model Number Outdoor Unit MXZ-2C20NA2 Indoor Unit Type Non-ducted Mix Ducted Outdoor Unit MCA A 17.2 17.2 17.2 Fan Motor Full Load Amperage A 1.77 1.77 1.77 Fan Motor Output W 64 64 64 Airflow Rate CFM 1,342 / 1,458 1,342 / 1,458 1,342 / 1,458 Refrigerant Control Liner Expansion Valve Liner Expansion Valve Liner Expansion Valve Defrost Method Reverse Cycle Reverse Cycle Reverse Cycle Heat Exchanger Type Plate Fin Coil Plate Fin Coil Plate Fin Coil Sound Pressure Level, Cooling*1 dB(A)50 50 50 Sound Pressure Level, Heating*2 dB(A)54 54 54 Compressor Type Twin Rotary type Twin Rotary type Twin Rotary type Compressor Model SNB140FQUH2T SNB140FQUH2T SNB140FQUH2T Compressor Motor Output kW 1.5 1.5 1.5 Compressor Rated Load Amps A 10.7 10.7 10.7 Compressor Locked Rotor Amps A 15.5 15.5 15.5 Compressor Oil Type // Charge oz.NEO22 // 20.3 NEO22 // 20.3 NEO22 // 20.3 External Finish Color Munsell 3.0Y 7.8/1.1 Munsell 3.0Y 7.8/1.1 Munsell 3.0Y 7.8/1.1 Base Pan Heater Optional Optional Optional Unit Dimensions W: In. [mm]33-1/16 [840]33-1/16 [840]33-1/16 [840] D: In. [mm]13 [330]13 [330]13 [330] H: In. [mm 27-15/16 [710]27-15/16 [710]27-15/16 [710] Package Dimensions W: In. [mm]40 [1,010]40 [1,010]40 [1,010] D: In. [mm]18-1/2 [470]18-1/2 [470]18-1/2 [470] H: In. [mm 33-1/2 [850]33-1/2 [850]33-1/2 [850] Unit Weight Lbs. [kg]126 [57]126 [57]126 [57] Package Weight Lbs. [kg]147 [67]147 [67]147 [67] Outdoor unit operating temperature range Cooling Intake Air Temp (Maximum / Minimum)°F 14 to 115 14 to 115 14 to 115 Heating Intake Air Temp (Maximum / Minimum)°F 5 to 75 5 to 75 5 to 75 Thermal Lock-out / Re-start Temperatures °F Cooling: 10.4 / 14 Heating: 1.5 / 5 Cooling: 10.4 / 14 Heating: 1.5 / 5 Cooling: 10.4 / 14 Heating: 1.5 / 5 Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US, LLC SPECIFICATIONS: MXZ-2C20NA2 Model Number Outdoor Unit MXZ-2C20NA2 Indoor Unit Type Non-ducted Mix Ducted Refrigerant Type R410A R410A R410A Charge Lbs. Oz.3, 15 3, 15 3, 15 Indoor Unit Connection Maximum Number of Connected IDU 2 2 2 Minimum Number of Connected IDU 2 2 2 Maximum Connected Capacity Btu/h 24,000 24,000 24,000 Minimum Connected Capacity Btu/h 12,000 12,000 12,000 Piping Gas Pipe Size O.D. (Flared)In. [mm]3/8 [9.52]3/8 [9.52]3/8 [9.52] Liqued Pipe Sixe O.D. (Flared)In. [mm]1/4 [6.35]1/4 [6.35]1/4 [6.35] Total Piping Length Ft. [m]164 [50]164 [50]164 [50] Maximim Height Differeence, ODU above IDU Ft. [m]33 [10]33 [10]33 [10] Maximim Height Differeence, ODU below IDU Ft. [m]49 [15]49 [15]49 [15] Farthest Piping Length from ODU to IDU Ft. [m]82 [25]82 [25]82 [25] Maximum Number of Bends 50 50 50 AHRI Rated Conditions (Rated data is determined at a fixed compressor speed *1 Cooling (Indoor // Outdoor)°F 80°F DB, 67°F WB // 95°F DB, 75°F WB *2 Heating at 47°F (Indoor // Outdoor)°F 70°F DB, 60°F WB // 47°F DB, 43°F WB *3 Heating at 17°F (Indoor // Outdoor)°F 70°F DB, 60°F WB // 17°F DB, 15°F WB Conditions *4 Heating at 5°F (Indoor // Outdoor)°F 70°F DB, 60°F WB // -4°F DB, -5°F WB For reference to connected capacity charts, please refer MXZ-2C20NA2-U1 Operational Performance. NOTES: Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US, LLC ACCESSORIES: MXZ-2C20NA2 Joint Pipe Port Adapter size: 3/8” x 5/8”PAC-SG76RJ-E Port Adapter size: 1/4” x 3/8”PAC-493PI Port Adapter size: 3/8” X 1/2”MAC-A454JP-E Port Adapter size: 1/2” X 3/8”MAC-A455JP-E Port Adapter size: 1/2” X 5/8”MAC-A456JP-E Air Discharge Guide MAC-856SG Base Pan Heater PAC-646BH-E Control Cable CW162S 3-pole Disconnect TAZ-MS303 M-NET Adapter PAC-IF01MNT-E Wall Mounting Bracket (Powder-coated Steel)QSWB2000M-1 Wall Mounting Bracket (316 Series Stainless Steel)QSWBSS Outdoor Unit Mounting Pad 24" x 42" x 3"ULTRILITE2 MiniSplit Mounting Stand-Single Fan - 12"QSMS1201M MiniSplit Mounting Stand-Single Fan - 18"QSMS1801M MiniSplit Mounting Stand-Single Fan - 24"QSMS2401M Diamondback Linesets*1 1/4 x 1/2 x 15’ / 1/2” Lineset (Twin-Tube Insulation)MLS141212T-15 1/4 x 1/2 x 30’ / 1/2” Lineset (Twin-Tube Insulation)MLS141212T-30 1/4 x 1/2 x 50’ / 1/2” Lineset (Twin-Tube Insulation)MLS141212T-50 1/4 x 1/2 x 65’ / 1/2” Lineset (Twin-Tube Insulation)MLS141212T-65 1/4 x 1/2 x 100’ / 1/2” Lineset (Twin-Tube Insulation)MLS141212T-100 3/8 x 5/8 x 10’ / 1/2” Lineset (Twin-Tube Insulation)MPLS385812T-10 3/8 x 5/8 x 15’ / 1/2” Lineset (Twin-Tube Insulation)MPLS385812T-15 3/8 x 5/8 x 30’ / 1/2” Lineset (Twin-Tube Insulation)MPLS385812T-30 3/8 x 5/8 x 50’ / 1/2” Lineset (Twin-Tube Insulation)MPLS385812T-50 3/8 x 5/8 x 65’ / 1/2” Lineset (Twin-Tube Insulation)MPLS385812T-65 3/8 x 5/8 x 100’ / 1/2” Lineset (Twin-Tube Insulation)MPLS385812T-100 *1 Linesets are indoor unit specific and will be listed in the IDU information - the Joint Pipe adaptors are used in this application 1340 Satellite Boulevard. Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US, LLC DIMENSIONS: MXZ-2C20NA2 Specification Submittal Data / Panasonic Ventilation Fan Description UL listed ceiling or wall mount Energy Recovery Ventilator provides a tempered air supply, humidity control, and a balanced amount of exhaust to help maintain neutral pressure throughout the home. Panasonic ERV shall not be installed in a bathroom. Only one unit is needed for a 1,750 sq. ft. 2 bedroom home to meet the ASHRAE 62.2 ventilation requirement. Motor/Blower: • Fully enclosed AC condenser motor rated for continuous run. • Power rating shall be 120 volts and 60 Hz. • Two highly efficient blower wheels running on single motor for lower power consumption and decreased noise. • Motor equipped with thermal cut-off fuse control. Housing: • Rust proof paint, galvanized steel body. • Dual 4" intake and exhaust ducts. • Built in backdraft damper on exhaust duct. • Filters on supply and exhaust air extend the life of the ERV core. • Expandable mounting bracket up to 16” on center. Grille: • Attractive design using ABS material. • Attaches directly to housing with torsion springs. Warranty: • All Parts: 3 Years from original purchase date. Architectural Specifications: ERV shall be ceiling or wall mount type with no less than 40 CFM on the exhaust port, 30 CFM on the supply port, and no more than 0.8 sone as tested in accordance with HVI 915 and 916 standards at 0.1 static pressure in inches water gauge. Power consumption shall be no greater than 23 watts. Apparent Sensible Effectiveness for heating shall be no less than 66% at 30 CFM net air flow under 32°F (0°C) as tested in accordance with CSA-C439. Total Recovery Effectiveness for cooling shall be no less than 36% at 29 CFM net air flow under 95°F (35°C). The supply port damper shall close below 20°F (-7°C) to prevent freezing of the core. The motor shall be totally enclosed, AC condenser type engineered to run continuously. Power rating shall be 120v/60Hz. Duct diameter shall be no less than 4". ERV can be used to comply with ASHRAE 62.2, LEED, IAP, California Title-24, and WA Ventilation Code. ERV Core Technology: • Indoor and outdoor air passes through Panasonic’s capillary core technology. This process tempers supply air while transferring moisture and energy. • Built in Frost Prevention Mode prevents the core from freezing. Frost Prevention Mode is free of interaction and operates without intervention. FV-04VE1 Panasonic Eco Solutions North America Eco Products Division Two Riverfront Plaza Newark, NJ 07102 us.panasonic.com/ventfans For complete Installation Instructions visit us.panasonic.com/ventfans Model Quantity Comments Project: Location: Architect: Engineer: Contractor: Submitted by: Date: VF11081SS-04VE1 Specifications: WhisperComfort FV-04VE1 Air Volume Setting 40 CFM 20 CFM 10 CFM Static Pressure in inches w. g.0.1 0.1 0.1 Exhaust Air Volume (CFM)40 20 10 Supply Air Volume (CFM)30 20 10 Noise (sones)0.8 <0.3 N/A Power Consumption (watts)23 21 17 Speed (RPM)1479 1292 1095 Current (amps)0.15 0.10 0.09 Power Rating (V/Hz)120/60 Apparent Sensible Effectiveness for Heating 66% at 30 CFM and 32°F (0°C) Total Recovery Efficiency for Cooling 36% at 29 CFM and 95°F (35°C) FV-04VE1 Two 4" ducts Energy Recovery Ventilator Optional Exterior Wall Cap and Elbow Accessories (see next page) Specification Submittal Data / Panasonic Ventilation Fan (Continued) FV-04VE1 Panasonic Eco Solutions North America Eco Products Division Two Riverfront Plaza Newark, NJ 07102 us.panasonic.com/ventfans VF11081SS-08VE1 Energy Recovery Ventilator 22-1/2 i n. 5 in .10-3/4 i n. 3-3/8 i n .5-9/16 i n. 8-5/8 in. 8-1/2 in. 4-1/2 in. Optional Elbow Optional Exterior Wall Cap Exterior Wall Cap FV-WC04VE1 polypropylene wall cap with styrofoam adaptor allows both exhaust (from the right) and supply (from the left) airflow through a 5.5"-5.75" hole in the building envelope. The dividers inside the bottom portion of the Y shape chamber and the new wall cap help prevent cross contamination. Elbow FV-EB04VE1 styrofoam elbow connects to the Y shaped adapter of the exterior wall cap to help simplify wall installation. The elbow also features double chambers for exhaust and supply air to help prevent cross contamination. Optional Accessories Exterior Wall Cap and Elbow Used Together Insulated duct Tape Tape OutdoorIndoor Elbow (FV-WC04VE1) Exterior wall Y-Shaped Adapter (FV-WC04VE1) Exterior Wall Cap (FV-WC04VE1) Specification Submittal Data / Panasonic ERV Description Ceiling or wall mount Cold Climate Energy Recovery Ventilator (ERV) provides a tempered air supply, humidity control, and a balanced amount of exhaust to help maintain balanced, positive or negative pressure throughout the home. Panasonic ERV is engineered for use in any North America climate zone. Only one unit is needed for a ≤ 3,000 sq. ft., up to 7 bedroom home to meet the ASHRAE 62.2 ventilation requirement. Built-in ASHRAE 62.2 Timing function helps ensure code compliance. Motor/Blower: • Two (2) enclosed DC brushless motors rated for continuous run. • ERV Supply and Exhaust ventilation rates shall be manually adjustable for 50-60-70-80- 90-100 CFM. • Power rating shall be 120 volts and 60 Hz. • Motor equipped with thermal cut-off fuse control. • Removable, permanently lubricated, plug–in motor. Housing: • 22 gauge galvanized steel body. • Four 4" or 6" intake and exhaust ducts. • Built in damper on Outdoor Air (OA) closes during defrost function when the outdoor temperature is too cold. • Filters on supply and exhaust air extend the life of the ERV core. • (4) Pressure ports allow for easy airflow verification. • Pre-drilled mounting bracket can accommodate 16", 19", or 24" on center. Maintenance: • MERV 8 filter included; MERV 8 (FV- FL0810VE1) and optional MERV 13 (FV- FL1310VE1) replacements available. • Unobtrusive alarm notifies owner for filter check and maintenance. Warranty: • DC Motors: 6 years from original purchase date • All Parts: 3 Years from original purchase date. Architectural Specifications: ERV shall be ceiling or wall mount type with built-in speed selectors for both Supply and Exhaust air. Select from 50/60/70/80/100 CFM. ERV shall have 95 Net CFM on the exhaust ports and 99 Net CFM on the supply ports as tested in accordance with HVI 915 and 916 standards at 0.1 static pressure in inches water gauge. ERV shall have 95 Net CFM on the exhaust ports and Net 101 CFM on the supply ports at 0.4" w.g. static pressure. Power consumption shall be no greater than 62 watts at 0.1" w.g. and 80 watts at 0.4" w.g. static pressure. Apparent Sensible Effectiveness for heating shall be no less than 90% at 54 CFM net air flow under 32°F (0°C) as tested in accordance with CSA-C439. Total Recovery Effectiveness for cooling shall be no less than 73% at 52 CFM net air flow under 95°F (35°C). The supply port damper shall close when outdoor temperatures are < 14°F (-10°C) to prevent freezing of the core. The (2) motors shall be totally enclosed DC brushless motors rated for continuous run. DC motor speed shall automatically increase when the fan senses static pressure to maintain selected CFM. ERV shall incorporate an ASHRAE 62.2 Timing function for code compliance. Power rating shall be 120v/60Hz. Duct diameters shall be no less than 4". ERV can be used to comply with ASHRAE 62.2, LEED, IAP, California Title-24, and WA Ventilation Code. ERV Core Technology: • Indoor and outdoor air passes through Panasonic’s capillary core technology. This process tempers supply air while transferring moisture and energy. • Built in Frost Prevention Mode prevents the core from freezing. Frost Prevention Mode is free of interaction and operates without intervention. FV-10VE1 Temperate Climate ERV Panasonic Eco Solutions North America Eco Products Division Two Riverfront Plaza Newark, NJ 07102 us.panasonic.com/ventfans For complete Installation Instructions visit us.panasonic.com/ventfans Model Quantity Comments Project: Location: Architect: Engineer: Contractor: Submitted by: Date: VF17024SS-10VE1 FV-10VE1 Four 4" or 6" ducts Energy Recovery Ventilator Optional Exterior Wall Cap (see next page) DC Motor Technology When the ERV senses static pressure, its speed is automatically increased to ensure that the desired CFM is not compromised, which allows the ERV to perform as rated.28-1/2'’8-7/8'’23'’4' ’ Di a6' ’ Di a6' ’ Di a4' ’ Di a13'’BE S T E NERGY EFFICI E N T PRODUCTBEST O F IB S AWARDS W IN N E R Specification Submittal Data / Panasonic ERV (Continued) Panasonic Eco Solutions North America Eco Products Division Two Riverfront Plaza Newark, NJ 07102 us.panasonic.com/ventfans VF17024SS-10VE1 22-1/2 i n. 5 in .10-3/4 i n. 3-3/8 i n .5-9/16 i n. 8-5/8 in. 8-1/2 in. 4-1/2 in. Optional Exterior Wall Cap Exterior Wall Cap FV-WC04VE1 polypropylene wall cap with styrofoam adaptor allows both exhaust (from the right) and supply (from the left) airflow through a 5.5"-5.75" hole in the building envelope. The dividers inside the bottom portion of the Y shape chamber and the new wall cap help prevent cross contamination. NOTE: FV-WC04VE1 is NOT recommended for use at CFM settings higher than 50 CFM. Optional Accessory Specifications: Intelli-Balance 100 FV-10VE1 Static Pressure in inches w. g.0.1 0.4 Net Exhaust Air Volume (CFM)95 95 Net Supply Air Volume (CFM)99.0 101 Power Consumption (watts)62.0 80.0 Power Rating (V/Hz)120/60 Energy Performance: Intelli-Balance 100 FV-10VE1 Supply Temperature Net Air Flow Power Consumed (Watts) Sensible Apparent Net Recovery Sensible Moisture °C °F L/S CFM Efficiency Effectiveness Transfer Heating 0 32 25 54 20 79 90 0.76 0 32 32 67 28 79 88 0.76 0 32 41 87 46 75 85 0.72 -25 -13 ------ -25 -13 ------ Cooling Total Recovery Efficiency 35 95 25 52 22 73 Performance Curve 4" or 6" ductFV-10VEC1 50-80-100 CFM 4 x 4" or 6" Ducts FV-10VE1 50-80-100 CFM 4 x 4" or 6" Ducts Static Pressure (inch w.g.)Airflow (CFM) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0 0 20 40 60 80 100 120 Net Supply Air Net Exhaust Air Static Pressure (inch w.g.)Airflow (CFM) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0 0 20 40 60 80 100 120 Net Supply Air Net Exhaust AirFV-10VEC1 50-80-100 CFM 4 x 4" or 6" Ducts FV-10VE1 50-80-100 CFM 4 x 4" or 6" Ducts Static Pressure (inch w.g.)Airflow (CFM) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0 0 20 40 60 80 100 120 Net Supply Air Net Exhaust Air Static Pressure (inch w.g.)Airflow (CFM) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0 0 20 40 60 80 100 120 Net Supply Air Net Exhaust Air BE S T E NERGY EFFICI E N T PRODUCTBEST O F IB S AWARDS W IN N E R FV-10VE1 Temperate Climate ERVEnergy Recovery Ventilator STANDARD CONSTRUCTION CABINET 20 (1.0) gage galvanized steel. PANELS 18 (1.3) gage galvanized steel. FINISH Polyester Resin based powder coat. Off White color. WHEEL ARI rated Internal Enthalpy Wheel. FILTERS Intake: Aluminum Mist Eliminator Exhaust: 2” Pleated TEMPERATURE LIMITS +10°F (-12°C) to. +115°F (+46°C). OPTIONS • Roof Curb • Low Ambient Kit (LAK) • Motorized Outside Air Damper (MOAD) • Motorized Exhaust Air Damper (MEAD) • Start-Stop-Jog (SSJ) • Disconnect for Field Installation (Disc) • Rotation Sensor (RS) • Pressure Sensor (PS) • Medium and High Pulley Kits (M or H) • Dirty Filter Switch (DFS) • Variable Frequency Drives (VFD) Dimensions shown in parentheses ( ) indicate millimeters. ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. 3900 Dr. Greaves Rd. • Kansas City, MO 64030 • (816) 761-7476 • FAX (816) 765-8955 O-SERIES ENERGY RECOVERY VENTILATOR OUTDOOR OVER AND UNDER DUCT ARRANGEMENTS FEATURES “O” series energy recovery ventilators are designed for outside use in rooftop or “pad” instal- lations where the application required a side-by-side duct system. One of the beneÀts of this design is the ability to be ducted directly to the back of a rooftop air conditioning unit. Another use is for “through the wall” applications. The horizontal return duct connection can be converted to bottom return in the Àeld. Balancing dampers should be utilized to help control the air volumes. Spec ERV-O-811/Replaces ERV-O-509 ©Ruskin 2011 !" # $ ! %#&' ( )) " ) $) ) *+, -+, (. / ERV with Horizontal Ductwork SPECIFICATIONS AND ELECTRICAL DATA Model Numbers O11-02 Stand Alone O/U 300 - 1100 CFM ERV O20-02 Stand Alone O/U 1200 - 2000 CFM ERV Line Voltage – 60hz 208/230v 1ph 208/230v 3ph 460v 3ph 575v 3ph 208/230v 3ph 460v 3ph 575v 3ph Fresh Air Blower Motor – hp 1.5 / Belt 2/ Belt Wheel Size (dia x width) – in 9 x 4 9 x 9 Motor Speed – rpm 1725 1725 Motor Speed(s) Adjustable Sheave Adjustable Sheave Bearing Type Ball Ball Full Load Amps 9.1 5.6 2.8 2.0 6.0 2.6 2.4 Service Factor 1.15 1.15 Exhaust Air Blower Motor – hp Stationary 1.5 / Belt 2 / Belt Wheel Size (dia x width) – in 9 x 4 9 x 9 Motor Speed – rpm 1725 1725 Motor Speed(s) Adjustable Sheave Adjustable Sheave Bearing Type Ball Ball Full Load Amps 9.1 5.6 2.8 2.0 6.0 2.6 2.4 Service Factor 1.15 1.15 Wheel Electrical Data Potential Volts 208 - 230 208 - 230 Motor Speed – rpm 1050 1050 Full Load Amps 0.3 0.3 Total Electrical MCA – Stationary 20.8 12.9 6.6 4.8 13.8 6.2 5.7 OCPD – Stationary 30 15 9 7 20 9 8 Wheel Data Wheel Depth – in 3 3 Wheel Diameter – in 25.3 30.346 Construction / Media Type One Piece / Polymeric One Piece / Polymeric Curb Curb Height – in 14 14 Weights Shipping Weight – lbs. (kg) 389 650 Net Weight – lbs. (kg) 314 570 O20 ARI CERTIFIED RATINGS Thermal Ratings @ 0” Pressure Diff. Sensible Latent Total Total Effectiveness 100% Air Áow Heating 68 61 65 75% Air Áow Heating 72 67 71 100% Air Áow Cooling 68 61 64 75% AirÁow Cooling 72 67 70 Net Effectiveness 100% Air Áow Heating 68 61 65 75% Air Áow Heating 72 67 71 100% Air Áow Cooling 68 61 64 75% AirÁow Cooling 72 67 70 Enthalpy Wheel ARI Rating Data O11 ARI CERTIFIED RATINGS Thermal Ratings @ 0” Pressure Diff. Sensible Latent Total Total Effectiveness 100% Air Áow Heating 76% 68% 73% 75% Air Áow Heating 81% 73% 78% 100% Air Áow Cooling 76% 68% 72% 75% AirÁow Cooling 81% 73% 76% Net Effectiveness 100% Air Áow Heating 76% 68% 73% 75% Air Áow Heating 81% 73% 78% 100% Air Áow Cooling 76% 68% 72% 75% AirÁow Cooling 81% 73% 76% Enthalpy Wheel ARI Rating Data Nominal AirÁow CFM 1600 @ .956 Nominal AirÁow CFM 1600 @ .956 EATR – -1.00 H2O7.80%OACF – -1.00 H2O0.97 EATR – 0.00 H2O 0.40% OACF – 0.00 H2O1.16 EATR – +1.00 H2O 0.00% OACF – +1.00 H2O1.29 Nominal AirÁow CFM 900 @ 1.06 Nominal AirÁow CFM 900 @ 1.06 EATR – -1.00 H2O9.30%OACF – -1.00 H2O0.97 EATR – 0.00 H2O 0.70% OACF – 0.00 H2O1.19 EATR – +1.00 H2O 0.00% OACF – +1.00 H2O1.34 Series Size Return Filter Intake Filter Qty Width Height Type Qty Width Height Type O 11 1 18 25 2” PLT 127.510 1” ME 20 2 16 16 1 32.25 18.5 28 2 20 20 1 40.25 21.5 36 2/1 16 / 14 20 1 40.25 21.5 46 2 24 24 1 40.25 21.5 62 5 14 20 1 40.25 25.5 Dimension (inches) “O” SERIES 11 20 28 36 46 62 A 12 12 12 12 12 12 B 36 36 36 36 36 36 C 48 60 60 60 60 60 D 36 36 36 36 36 36 SERVICE CLEARANCES FILTER SIZES