Loading...
BLD2021-0646_Manufacturer_Specifications_and_Installation_Instructions_5.10.2021_11.05.39_AM_21874805581701-CTG-E-0221 PHYSICAL AND ELECTRICAL DATA MODEL TC4B1822S TC462422S TC41330225 I TC4B3622S TC4134222S TC4B4821S TC4136021S Unit Supply Voltage 208-230 V, 1(), 60 Hz Normal Voltage Range f 187 to 252 Minimum Circuit Ampacity 12.7 14.8 18.4 19.6 25.3 25.7 31.7 Maximum Overcurrent Device (A)2 20 25 30 30 40 45 50 Minimum Overcurrent Device (A)3 15 15 20 20 30 30 35 Compressor Type Scroll Scroll Scroll Scroll Scroll Scroll Scroll Compressor (A) Rated Load 9.7 11.2 14.1 14.7 19.2 19.5 24.3 Locked Rotor 46.0 60.8 73.0 75.0 123.9 130.0 144.2 Crankcase Heater No No No No No No No Factory External Discharge Muffler No No No No No No No HS Kit Required with TXV No No No No No No No HS Kit Part Number (S1-2SA067*****)4 21806 21806 10106 10106 10106 10106 10106 Fan Diameter (in.) 18 22 22 22 22 24 26 Rated HP 1112 1/8 1/8 1/4 1/4 1/4 1/4 Fan Motor Rated Load (A) 0.64 0.80 0.80 1.30 1.30 1.30 1.30 Nominal RPM 1050 1075 1075 850 850 850 850 Nominal CFM 1900 1950 2850 3225 3275 3500 4300 Face Area (ft) 11.07 12.21 12.21 13.83 17.37 18.74 23.40 Coil Rows Deep 1 1 1 1 1 1 1 Fins per Inch 23 23 23 23 23 23 23 Liquid Line Set OD (Field Installed) 3/8 3/8 3/8 3/8 3/8 3/8 318 Vapor Line Set OD (Field Installed) 5 3/4 3/4 3/4 3/4 718 7/8 1-1/8t Unit Charge (lb -oz)6 3-8 3-12 3-14 4-1 4-12 4-15 5-12 Charge (oz/ft) 0.62 0.62 0.62 0.62 0.67 0.67 0.75 Operating Weight (lb) 140 155 155 180 215 200 205 1. Rated in accordance with AHRI Standard 110-2012, utilization range "A". 2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection. 3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection. 4. Use S 1-2SA067***** series kit. See the Hard Start Kit Accessory Installation Manual. 5. For applications with non-standard vapor line sizes, see the APPLICATIONS AND ACCESSORIES section. 6. The unit charge is correct for the outdoor unit, smallest matched indoor unit, and 15 ft of refrigerant tubing. For tubing lengths other than 15 ft, add or subtract the amount of refrigerant, using the difference in actual lineset length (not the equivalent length) multiplied by the per foot value. DIMENSIONS Unit Model Dimensions (in,) Refrigerant Connection Service Valve Size A I B C Liquid Vapor TC4B1822S 30 24 24 3/8 3!4 TC462422S 26 3/4 291/4 291/4 TC463022S 26 3/4 291/4 291/4 TC4B3622S 30 291/4 291/4 TC464222S 361/4 291/4 291/4 7/8 TC4134821S 331/4 351/4 313/4 TC4B6021S 361/4 38 341/4 7/8t t Adapter fitting must be field installed for the required 1 1/8-in. line set. All dimensions are in inches and are subject to change without notice. Overall height is from bottom of base pan to top of fan guard. Overall length and width include screw heads. 5581701-CTG-E-0221 APPLICATIONS AND ACCESSORIES Refer to the Price Manual for specific model numbers. Standard Application Limits* Maximum Lineset Equivalent Length 80 ft Outdoor Ambient Temperature Limits Cooling Operation Maximum DB 125*F Minimum DB I 55'F "For Low Ambient and/or Long Lineset Applications, seethe accessories listed below. Non -Standard Lineset Applications - For installations with reduced diameter or long linesets, refer to the current version of the Piping Application Guide PIN 247077, available in the Appli- cation Bulletins section on yv4vty_;irt�t�lyg.tkirigj�gB rctt�t. OD Unit Anti -Short Cycle Kit (10 Pack) (S1-2TD08700124BK): A time delay that prevents rapid com- pressor restarting as a result of power interruption, limit switch operation, or thermostat resetting. Not required for AC models with factory electronic controls. Standard Low Ambient Control Kit (S1-2LA06700424): Allows the use of air conditioning at low outdoor ambient tem- peratures down to +20°F (-7°C). For use with all R-410A single - stage AC models. Advanced Low Ambient Control Kit (S1-2LA04701024): Contains the necessary components and controls to allow cool- ing operation down to -20OF (-290C). For use with some R-410A single -stage AC and HP models. This accessory can only be applied to models that contain a PSC outdoor fan motor. Low Pressure Switch Kit (S1-2PS06700524): Provides field installed low pressure (loss of charge) protection. Not required for AC models with factory electronic controls. High Ambient Outdoor Fan Motor (S1-FHM****HT): Class F 70°C motor to allow cooling operation up to 160°F air entering the outdoor coil. For use with all R-410A single -stage AC mod- els containing R-410A refrigerant only. Outdoor Communicating Board Kit (S1-33102952310): Elec- tronic control upgrade for standard AC units to provide compati- bility with the Hx711 Touch Screen Thermostat used in communicating mode. Start Assist Kit (S1-2SA067*****): Provides increased com- pressor starting torque for areas with low supply voltage. Required for units with reciprocating compressors when applied with indoor TXV, and for all units when applied with long linesets or low ambient kits. May be factory installed on select AC units (see the PHYSCIAL AND ELECTRICAL DATA table). Refer to the Price Pages or Source 1 SmartSearch for the correct kit for each application. SOUND POWER RATINGS Compressor Crankcase Heater Kit (S1-025-*****= **): A wrap -around electrical resistance heater that warms the com- pressor sump, reducing the chance of liquid slugging on startup. Required on all long lineset and low ambient applica- tions. Refer to the Price Pages or Source 1 SmartSearch for the correct part for each application. Anchor Bracket Kit (S1-lHK0601): Firmly anchors unit to pad or support structure. When properly installed, approved for ground -mounted or roof -mounted applications. Indoor TXV Kit (S1 -1 TVM***): Thermal expansion valves pre- cisely meter refrigerant for optimum performance over a wide range of conditions. See the SYSTEM CHARGE FOR VARI- OUS MATCHED SYSTEMS table or refer to the Price Pages or Source 1 Smart Search for the TXV part number for each AC model. Winter Cover Kit (S1-CCVRE***): Custom fit winter cover pro- tects AC outdoor unit from debris during the off-season. Remove before unit operation. Refer to the Price Pages or Source 1 SmartSearch for the correct cover for each applica- tion. Cold Weather Charging Tent (S1-CHGTENT01): Provides warm environment to accurately service AC systems in ambient conditions 55°F (131C) or colder. Touch-up Paint (S1-5130153****: Color matched aerosol paint for touching up unit chassis and panels. Refer to the Price Pages or Source 1 SmartSearch for the correct color for each application. Compressor Sound Blanket (S1-010-07xxx-000): A field installed dense foam cover that provides 2 dBA sound level reduction. Refer to the Price Pages or Source 1 SmartSearch for the correct blanket for each application. Thermostat: Compatible thermostat controls are available through accessory sourcing. For optimum performance, these outdoor units are fully compatible with our residential HxTM Touch Screen Thermostats available through Source 1. For more information, refer to the Thermostats & Controllers section of the Offering Catalog. Cooling Octave Band Sound Power Level (dB re 1 pW) Model Number 63 125 250 500 1000 2000 4000 8000 dBA SQI TC4B1822S 69.7 66.7 65.5 65.2 69.8 65.1 63.1 60.6 73.0 19.2 TC4B2422S 68.7 74.0 68.6 72.9 70.5 67.3 63.8 60.7 74.0 19.1 TC4B3022S 68.8 67.4 64.8 69.1 69.7 63.1 57.3 53.6 74.0 19.1 TC463622S 71.7 72.4 69.4 71.0 70.3 63.4 60.2 55.3 74.0 19.0 TC4B4222S 71.5 74.9 67.1 70.6 67.0 63.2 58.7 56.6 74.0 19.2 TC4B4821S 68.6 76.8 71.4 71.4 70.9 63.8 60.9 58.7 75.0 19.0 5581701-CTG-E-0221 TYPICAL INSTALLATION A CAUTION: Sr.retjBl t-caJ-C- fijLj(,t 1.)n taken to avoid fecirculstion 1)f disr-barge Z-.IiV 11TOLI(JI1 OW001' Coll. NOTE: ..... ..... 11SUIC willi Suppoll. CLASS I WIRING s THERMOSTAT 4 DISCONNECT SWIT01 I :;J� NEC CLASS 21NIRIW3 k 3 BRAC S --- W.(., for wall MCAM.t Mill A: enl:(ir brace under NOTE: Centel of Compressor. Ens re a ininirrIUM. Of TO FURNACE OR 2-1'• clearance belymer, I AIR HANDLER A\ 3 arty two uAils. TERMINAL BLOCK Z NEC, 0I.A,5S 2 WIRI NG l(YCI-EARANCE AROUND PERIMETER �6 .. di,33ranro :as i ni.5sible. on One side only, see Installation Cleararu,ec,j J CONTROL ACCES,� Of. -..AL OPENING8 FIAN E. I N I'l 1. 1 -VV I N G \ -- r SNOW PUMPAPS mr,rily Use I,*rmaqunn or GqUiVAIMI U%0 in dfq) snow areas rZOR with fifth pu rnp-u 1) under NOTE: % .enter Of compressor.All outdoor vAing MINIMUM 14l'SERVICEACCESS CLEARANCE must be weett lerfaroof. Mololain minimurn dearance On one side Of access panel. ACAUTION Care must be taken to prevent ice from damaging the unit. Damage may occur from ice failing onto unit from a sloped roof or from a vertical drip line due to a partiat overhang. NO OWERHANG COVERING UNIT OVERHANC(XX-APLE .i.Y COVERING UNIT A( 48" MINIMUM OVERHEAD ......... . t INSTALLA, WN ACUPTABIA; INS'TALI.ATION ACCEPTABLE (Refer to CAUTION above.) NOTE: The unit must be installed on ji solid base above. the grade. Me base must not be able to settle or shifIl causing strait) on OVERHANG PAIRTIALL COVERING UNIT i. j .. ...... INS'IALLAI ION NOTRECOM-111ENDED (Refer to CAUTION above.) NOTE; install unit on flat surface:. If installation surface is slope�tl, ensure :hat unit slopes away from house structure al, 1/4" per fool. TYPICAL FIELD WIRING 5581701-CTG-E-0221 ALL FIELD WIRING TO BF,'' IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES E'UW!_I: L'y'Ir21Wc:i 4 VOID C;O\'TROL'J111'�1NG thiN[hNiUM 1ki(.,A.lktIRE CLAss 2) 7 E:RIviINAL W IS ONLY REQUIRED ON SYSTEM ! "J'Jr7N HE W". € CONTACTOR € TETUVIINALS r 0_ 1 C;C)IL LUG OUTDOOR UNIT POWER �hAR'ING CON T ROI.. "PORING FACTORY',NIRINC, FURNACE Or;AIR IIANDUI ' t I EAMINAL BLOGK € € € 1 I I ! I 1 € �Y) ROOM, THERMOSTAT ALL OUTDOOR WIRING MUST tie YUEAT1IFRpI. OO :USE COPPER CONr.)UCITORS ONI Y , ALTERNATIVE INSTALLATION CLEARANCES MINII•,'J)M! CLEARANCE U'E"I EEN UNITS "i i i:t.. 24 r L:Nc;r ---€► 24 za° NOTE: SERVICE , SERVICE st_.t_ .I7� . Clearance lt etwcen two tits nra l)o I IC i MdLiced to18" minintumprovided .......- . .... ... �; the service access clearance is ? z" ` " 4y increased to 24" minimtun, and the; :F*29 '� n'. �F3" ��//��Fij,";?�'� clearance on oath rermaininfg, silo UNIT !'': maintained al 12 minimum. ..�ay:i �;iil�;" UNIT. �,;'•,.,;;t... fa.., is n i rO Urdll' , c ; ,�,'i.a TO -UNIT ! c I NOTE: . Clearance to one Side of the ... MINIMI-IM C:1.1=ARANC;E FROM NJAjA_ Wit May he reduced to 6" provided j:,.; is the Cl(WO Me Lo each remaining side; :',...�:.....:::.. .:'. ..... ., .... ..... ... ....., .. .... ...... . . is Increased to 12" rninirrium, the service .access is increasad to 24,. ,' t ittinirnum, and the clearances between vt two units i maintained y i s s ma ntaine at z4" '.., �': °, 14 ........., SERVICE r••, minimum. ?a'":a'"r�` �;;;I Fl • r r t?;r �EI�� II,L i AND UNE7-✓f_�:-; ` TO-UNIT' 1"=1�I,!r,. M���� �\'xi3`;�,;;;• ::,•t a7' 12 12_,y .... Special care must be taken to avoid recirculation of discharge air through outdoor coil. � , .,