BLD20171071 (2)of EDMo�O
CITY OF ED�.-ONDS
121 STH A VENUE NORTH - EDMO - A� t810 L
o PHONE: (425) 771-0220 - FAX: (425) 77MI21
'A
nc to
STATUS: ISSUED 01/29/2018 Permit #: BLD20171071
Expiration Date: 01/29 A)IIJ L _Project Address: 92ND AVE W, ED1MONDS,
Parcel No: 00752100000300 f?eY)PAA1e&
PROPERTY OWNER APPLICANT CONTRACTOR
RODNEY & JULIA CASPER RODNEY & JULIA CASPER HOMEOWNER
21421 92ND AVE W 21421 92ND AVE W
EDMONDS, WA 98020 EDMONDS, WA 98020
(206)595-6572 (206)595-6572
LICENSE #: EXP:
r: ID. rr.
ADDITION OF MASTER BEDROOM/BATH AND GARAGE(WORKSHOP)
PLUMBING AND MECHANICAL INCLUDED
VALUATION: $102,709
PERMIT TYPE: Residential
PERMIT GROUP: 02 - Addition
GRADING: N CYDS: 0
TYPE OF CONSTRUCTION: VB
RETAINING WALL ROCKERY:
OCCUPANT GROUP:
OCCUPANT LOAD:
FENCE: ( 0 X 0 FT.)
CODE: 2015
OTHER: ------- OTHER DESC:
ZONE: RS-8
NUMBER OF STORIES: 1
IVESTED DATE:
NUMBER OF DWELLING UNITS: 1
LOT #:
LXISTING AREA
BASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0
I
IBASEMENT: 0 1 ST FLOOR: 720 2ND FLOOR: 0
3RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0
13RD FLOOR: 0 GARAGE: 0 DECK: 484 OTHER: 0
BEDROOMS:0 BATHROOMS:O
JBEDROOM&] BATHROOMS:I
FRONT S i ACK SIDESETBACK
REQUIRED: 7.5'N PROPOSED: 26'N REQUIRED: 7.5'E PROPOSED: ITT IREQUIRED: 7.5'W PROPOSED: NA
HEIGHT ALLOWED:O PROPOSED:O IREQUIRED: 7.5'S PROPOSED: ITS
SETBACK NOTES:
I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO
PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMEN'S COMPENSATION
INSURANCE AND RCW 18:27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID.
yAq-
Signature Print Name Date t Released IBV Date
ATTENTION
ITIS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF
OCCUPANCY HAS BEEN GRANTED. UBC109/ IBCI 10/ IRCI 10.
FIRE APPLICANT ASSESSOR a I CITY
f —�
0
STATUS: ISSUED BLD20171071
CONDITIONS
• Final approval on a project or final occupancy approval must be granted by the Building Official prior to use or occupancy of
the building or structure. Check the job card for all required City inspections including final project approval and final
occupancy inspections.
• Any request for alternate design, modification, variance or other administrative deviation (hereinafter "variance") from
adopted codes, ordinances or policies must be specifically requested in writing and be called out and identified. Processing
fees for such request shall be established by Council and shall be paid upon submittal and are non-refundable.
• Approval of any plat or plan containing provisions which do not comply with city code and for which avariance has not been
specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision
of city code or state law does not approve any items not to code specification.
• Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits
ofECC Chapter 5.30 only during the hours of 7:00amto 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding
Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the
noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120.
• Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold
harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of
whatever nature, arising directly or indirectly from the issuance f6r this permit. Issuance of this permit shall not be deemed to
modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance
provision.
THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY
CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT
TIME LIMIT: SEE ECDC 19.00.005(A)(6)
BUILDING
ENGINEERING (425) 771-0220 EXT. 1326
1. Go to: www.edmondswa.gov
Building Department Inspections
2. Then: Services
are now scheduled online. If you
FIRE (425) 775-7720
3. Then: Permits/Development
have difficulties, please call the
4. Then: Online Permit Info
Building Department front desk for
PUBLIC WORKS (425) 771-0235
5: If you don't have one already, create a
assistance during office hours.
login (upper right hand corner)
(425) 771-0220
RECYCLING (425) 276-4801
6: Schedule your inspection
When calling for an inspection please leave the following information: Permit Number, Job Site Address, Type of Inspection
being requested, Contact Name and Phone Number, Date Preferred, and whether you prefer morning or aftemoon.
• E-Erosion Control/Mobilization
• E-Footing Drain Connection
• E-Engineering Final
• B-Preconstruction meeting
• B-Setbacks
• B-Footings
• B-Foundation Wall
• B-Foundation Drainage
• B-Isolated Footings/Piers
• B-First Floor Framing
• B-Plumb Rough In
• B-Mechanical Rough In
• B-Exterior Wall Sheathing
• B-Roof Sheathing
• B-Window Flashing
• B-Shear Nailing
• B-Height Verification
• B-Framing
• B-Wall Insulation/Caulk
• B-Insulation/.Energy
• B-SheetrockNail
• B-Building Final
DEVELOPMENT SERVICES
RESIDENTIAL BUILDING PERMIT
APPLICATION
Fst 1 g90 121 5"' Avenue N, Edmonds, WA 98020
City of Edmonds Phone 425.771.0220 Q Fax 425.771.0221
PLEASE REFER TO THE RESIDENTIAL BUILDING CHECKLIST FOR SUBMITTAL REQUIREMENTS
ECT CT ADDRESS�treet�Suite #, City State, Zip):
PROJ00
Parcel #: `�,l�O�
V
Subdivision/Lot #:
Project Valuation: $
APPLICANT:
G d 7TV 1 t C o�-
Phone:
—_ 6�'7
Fax:
Address (Street, City, State, Zip):
q "a
E-Mail Address:
PR PERTY OWNER:
o e.�
Phone:
�-� -057a
Fax:
Ad i ess (Street, City, State, Zip):
A.A•e iv
E-Mail Address:
LENDING AGENCY:
Phone:
Fax:
Address (Street, City, State, Zip):
E-Mail Address:
CONTRACTOR:* (�
Phone:
Fax:
Address (Street, City, State, Zip):
E-Mail Address:
*Contractor must have a valid City of Edmonds business license prior to
doing work in the City. Contact the City Clerk's Office at 425.775.2525
WA State License #(Exp. Date:
A)ffg
City Business License #/Exp. Date:
DETAIL THE SCOPE OF WORK: &V RO-OY'l
PROPOSED NEW SQUARE FOOTAGE
FOR THIS PROJECT:
Basement: s . ft.
Select Basement Type: Finished LA Unfinished Ll
l't Floor: 752,6 s . ft.
Garage/Carport: 41 s . ft.
grid Floor: s . ft.
Deck/Cvrd Porch/Patio: s . ft.
Bedrooms # Full-3/4 Bath # Half -Bath #
Other: sq. ft.
Fire Sprinklers: Yes
E
No
Retaining Wall: Yes
LJ No
Grading: Cut cu. yds. Fill cu.yds.
I Cut/Fill in Critical Area. Yes LJ No "
I declare under penalty of perjury laws that the information I have provided on this form/application is true, correct and
complete, and that I am the property owner or duly authorized agent of the property owner to submit a permit application to
the City of Edmonds.
Print Name: :5 V t ta, evs�Q,r Owner 1 'IN Agent/Other ❑ (specify):
Signature: Date:
FORM A LABuilding New Folder 2010\DONE & x-ferred to L-Building-New drive\Form A2014.docx Updated: 1/17/2014
EXEMPTION FROM CONTRACTOR
REGISTRATION VERIFICATION
FORMI)
The undersigned property owner or authorized person as described below, has applied for a
building permit from the City of Edmonds and claims that he/she/it is exempt from providing
contractor registration in accordance with the provisions of RCW 18.27. The property owner or
authorized person, by their signature below, hereby verifies to the City of Edmonds that:
❑ Valve of work under $500.00. The aggregate contract price of labor and materials and all
other items required for the project is less than $500.00 and.is not part of a larger operation
to be undertaken on the property. This exemption does not apply to a person who advertises
or puts out any sign or card or other device which might indicate to the public that lie/she is
a contractor, or that he/she is, qualified to engage in the business of contractor. RCW
18.27.090(9).
❑ Owner who contracts for a project. A property owner contracting with registered
contractors for the project, and who him/herself is not performing any activity of a
contractor for the purpose of leasing or selling improved property that he/she has owned for
less than twelve months. RCW 18.27.090(11).
1 Work performed personally on own.property. Anyone personally working on property
V he/she owns, or at which he/she resides, as long as the property owner, or resident, does not
perform any activity of a contractor on his/her property for the purpose of selling,
demolishing, or leasing the property. RCW 18.27.090(12).
❑ Use of own employees. Property. owner using him/herself or his/her own employees to
perform maintenance, repair, and. alteration work in or upon his/her own property. RCW
18.27.090(13).
❑ Licensed Architect, engineer, electrician or plumber. All work performed under this
permit will be performed by an architect, civil or professional engineer, certified electrician
or certified plumber operating within the scope of his/her certification. RCW 18.72.090(14).
❑ Other. Specify which provision of RCW 18.27.090 applies:
THE UNDERSIGNED PROPERTY OWNER OR AUTHORIZED PERSON HEREBY VERIFIES
THAT ALL INFORMATION PROVIDED ON THIS FORM IS TRUE AND ACCURATE TO THE
BEST OF HIS OR HER KNOWLEDGE AND ACKNOWLEDGES THAT IF ANY OF THE
INFORMATION PROVIDED ON THIS FORM IS FALSE BE OR SHE UNDERSTANDS THAT THE
BUILDING PERMIT WILL BE EY&JEDIATELY REVOKED AND ALL FEES PAID FORFEITED.
DATED this day of 320.
PROPERTY OWNER/AUTHORIZED
. PERSON n
Signature V
Print Name
WITNESS.
Signature
Print Name
LATEMP\BUILDING\IIANDOUTS REVISED IN 2009\PREVIOUS HANDOUTS\FORMS\CONTRACTOR EXEMPTION FORM
D.DOCREVISED 7/07
GENERAL NOTES
LIVE SAYET Y N OTES (continued)
FRAMING NOTES (continued
Nothing in this permit approval process shall be interpreted as
allowing or permitting the maintenance of any currently existing
illegal, nonconforming, or unpermitted building, structure, or site
condition which is outside the scope of the permit application,
regardless of whether such building, structure, or condition is
shown on the site plan or drawing. Such building, structure, or
condition may be the subject of a separate enforcement action.
Sound/noise originating from temporary construction sites as a
result of construction activity are exempt from the noise limits
only during the hours of 7:00am to 6:00pm on weekdays and
10:00am and 6:00pm on Saturdays, excluding Sundays and
Federal Holidays. At all other times the noise originating from
construction sites/activities must comply with the noise limits,
unless a variance has been granted. ECC Chapter 5.30
All changes in plans and field modifications shall be approved by
the local jurisdiction. The design professional shall prepare
drawings as required for approval. IBC 107.4
Temporary address shall be clearly visible from street during all
phases of construction. Failure to properly post house/building
numbers may result in no inspection by the City Inspector.
Curb signage is not acceptable.
Address numbers (4" min. ht. & 1/z" min. stroke width) shall be
posted to be plainly visible from the street or road fronting the
property. IRC R319
LIFE SAFETY NOTES
Smoke alarms shall be installed in each sleeping room, outside of
each separate sleeping area in the immediate vicinity of the
bedrooms, and on each level (including basements and habitable
attics) in new construction and in existing dwellings when
alterations, repairs or additions requiring a permit occur. Smoke
alarms shall be hard -wired with battery backup, and when more
than one smoke alarm is required within an individual dwelling
unit, they shall be interconnected. Discuss exceptions to the
power source requirements with the Building Inspector.
IRC R314 IBC 907.2.11.2
Carbon monoxide alarms shall be installed outside of each
separate sleeping area in the immediate vicinity of the bedrooms
and on each level in new construction and in existing dwellings
when alterations, repairs or additions requiring a permit occur, or
when one or more sleeping rooms are added or created. IRC R315
Handrails and guards must be capable of resisting a concentrated
load of 200 pounds per square foot applied in any direction at any
point along the top. Guard in -fill components must be capable of
resisting 50 pounds per square foot.
IRC Table R301.5 IBC 1607.8
Handrails shall be continuous through stair flights of four or more
risers, without interruption by newel posts (unless at a turn) or
other obstructions, and return to a wall, newel post, or safety
terminal. The grip -size shall be Type I or II or of equivalent
graspablity. IRC 311.7.8
one operable escape window in the basement, habitable
attic and in each sleeping room meeting all of the following
requirements:
-An operable area of not less than 5.7 sq. ft. (5 sq. ft. for grade
floor opening)
•A minimum clear opening height of 24 inches
•A minimum clear opening width of 20 inches
-Not more than 44 inches between the finished floor and the
bottom of the clear opening.
Escape windows located under decks or porches must have a path
36 inches in height to a yard or court. R310 IBC 1029
The greatest riser height within any flight of stairs or the greatest
tread depth within any flight of stairs shall not exceed the smallest
by more than 3/8 inch.
IRC R311.7.5.1 IRC R311.7.5.2 IBC 1009.7.4
FOOTINGS/FOUNDATIONS
Footing drains are required around concrete/masonry foundations
that retain earth and enclose habitable or usable spaces located
below grade, or for crawl spaces when a minimum 6 inch slope
within the first 10 feet of the foundation wall is not achieved. A
separate footing drain inspection by the Building Inspector is
required. IRC R401.3 IRC R405.1
Slab -on -grade floors shall be a minimum 3.5-inch thick concrete
over a 6 mil vapor barrier and 4-inch base of sand/gravel/etc.
There shall be a thermal -break for slabs inside a foundation wall,
and if the slab is less than 24" below the exterior grade, 24" wide
R-10 perimeter insulation must be provided. Slabs used as part of
a hydronic heating system shall have R-10 insulation provided
throughout the entire slab area.
IRC R506 WSEC R402.2.9 WSEC Table R402.1.1
Vertical rebar must be hooked and tied in place at time of footing
inspection. Maintain minimum 3" clearance to earth, 1-1/2" to
form -work for reinforcement. R403.1.3 R404.1.2.3.7.4
Anchor bolts shall be at least 1/2 -inch in diameter and extend 7
inches into concrete. There shall be a minimum of two bolts per
plate, with one bolt within 12 inches but not closer than seven bolt
diameters from the end of the plate. The bolt spacing shall not
exceed 6 feet o.c. and shall have a nut and 3"x3"x0.229" washers
unless engineered. IRC R403.1.6
FRAMING NOTES
Hardware and fasteners in contact with preservative -treated wood
shall be of hot -dipped zinc galvanized steel, stainless steel, silicon
bronze or copper. IRC R317.3.1 IBC 2304.9.5.1
Joists less than 18" and beams less than 12" to grade and all wood
exposed to weather shall be preservative -treated or naturally
resistant to decay. IRC R317 IBC 2304.11
Joists shall have not less than 1.5 inches bearing on wood or metal
and 3 inches on concrete. Joists shall be prevented from rotating
at the ends and at intermediate support by approved hangers, 2
inch nominal blocking, or attachment to a rim board.
IRC 502.6/502.7 IBC 2308.8
Foundation cripple walls shall be framed of studs not less in size
than the studs above. Walls over 4 feet in height shall be framed
of studs having the size required for an additional story. Cripple
walls studs less than 14 inches in height shall be sheathed on at
least one side with a wood structural panel that is fastened to both
the top and bottom plates in accordance with Table R602.3(1), or
cripple walls shall be constructed of solid blocking. Cripple walls
shall be supported on continuous foundations. IRC R602.9
Prior to the framing inspection, the building must be dried in with
a minimum of roofing, windows, and siding paper installed.
Truss layouts showing girder truss/hip-master locations are not
permitted to change and must be followed correctly. If the truss
manufacturer requests to change, in part or in whole, the layout
shown, they must contact the architect/designer to ensure that the
structural design of the building is maintained. If the layout
shown is changed, in part or in whole, the Building Division
requires new engineering calculations and must approve the
changes prior to the installation of the roof sheathing.
Exterior and bearing wall studs may be notched <25% and bored
<40% of the stud width. Non -bearing wall studs may be notched
<40% and bored <60% of the stud width. Any bore located <5/8"
from the stud face is considered a notch. Rafters and joists may
be notched in the outer thirds of the span with a maximum notch
depth 1/6th and a notch width 1/3rd the depth of the member.
Rafters and joists may be bored up to 1/3rd the depth of the
member no closer than 2" to each edge or to another bore. Top
plates notched or bored >50% of the width must have a 16ga.
strap, 6 inches past and fastened with 8-10d nails at each side of
the opening. IRC R502.8 IRC R602.6 IBC 2308
Attic access openings are required for buildings with combustible
ceiling or roof construction over an area >30 sq. ft. and with a 30"
vertical space between ceiling and roof framing members. The
rough -framed opening shall be 22"x30" and located in a hallway
or other readily accessible location. The access cover shall be
weather-stripped and insulated to a level equal to the surrounding
surfaces. IRC R807.1 WSEC 402.2.4
Attic ventilation openings shall not be less than 1/150 of the area
of the space ventilated. It may be reduced to 1/300 if at least 50
percent and not more than 80 percent of the required openings are
at least 3 feet above the eave vents with the balance provided by
the eave vents. The net free cross -ventilation area may also be
reduced to 1/300 when a Class I or II vapor barrier is installed on
the warm -in -winter side of the ceiling. IRC R806.2
ADDITIONAL REQUIREMENTS
A survey may be required prior to the foundation wall inspection if
the Building Inspector is unable to verify setbacks. Lot line stakes
should be in place at the time of the foundation inspection and
established property pins should be made visible.
CN
MECHANICAL N W ES
PLUMB N(J INUlLJ
PIKL-KA l LL) UUN J l K U U l 1UN
Provide outdoor air inlets in all habitable spaces.IRC 1507.3.4.4
A 30"00" level working space shall be provided in front of the
control side to service appliances. In attics and underfloor areas,
a passageway a minimum of 30 inches high and 20 inches wide
traveling not more than 20 feet from the access shall be provided.
A 24 inch wide solid pathway shall be provided in attics. A
switch -controlled luminaire is required at the passageway opening
and a receptacle outlet at or near the appliance. A means of
electrical disconnect is required within sight of the appliance or
the breaker is to be capable of being locked in the open position.
IRC M1305 IMC 306 NEC 422.31(B)
Provide the combustion air required for the proper operation of the
appliance(s). The minimum required volume per the standard
method is 50 cubic feet per 1000 BTU/hr. Where exhaust fans,
clothes dryers, and kitchen ventilation systems interfere with the
operation of appliances, makeup air shall be provided. Fuel -fired
appliances shall not be located in sleeping rooms, bathrooms,
toilet rooms, or storage closets unless specific installation
requirements are met. IRC G 2406.2 G2407.4 G2407.5.1
IFGC 303.3 304.4 304.5
An exhaust hood/system of >400cfm installed or required by the
range or cooktop manufacturer must be provided with makeup air
equal to the exhaust air rate. IRC M1503.4 IMC 505.2
Provide required makeup air in the laundry room. Louvered doors
or openings/grilles into other spaces may be used to meet the
requirements. Other limitations may arise if a gas dryer is
installed. IMC 504.5 G2407.4 G2407.9.1
Dryer ducts shall terminate outside of the building, 3 ft. from any
openings into the building. The termination shall have a backdraft
damper and no screen. The dryer duct shall be a minimum
.016-in. (27 ga.) thick, a minimum 4 inches in diameter, have a
smooth interior finish, have sections joined with the insert end in
the direction of airflow without the use of fasteners, be supported
at 4 ft. intervals, and secured in place and protected by nail plates
that extend 2" above/below bottom/top plates. The joints shall be
sealed with UL181A listed mastic or tape. Dryer duct maximum
lengths are 25 ft. for electric and 35 ft. for gas with deductions for
fittings (or sized/length per manufacturer). If concealed, the
equivalent length of the duct shall be permanently labeled or
tagged within 6 ft. of the dryer connection.
IRC M1502 M1601.4.1 G2439 IMC 504 IFGC 614
Hydronic heating system piping shall be tested at 100 psi water
pressure or 1 1/2 times the operating pressure, whichever is greater,
for a minimum of 15 minutes. Piping embedded in concrete shall
be pressure tested prior to the placing of concrete and be
maintained at operating pressure during concrete placement. The
test must be observed by the Building Inspector prior to concrete
placement. Note: a means of providing outdoor air per IRC
R303.4, M1507 and IMC 403.2 is required. IMC 1208 - 1209
Refrigerant circuit access ports located outdoors shall be fitted
with locking -type tamper- resistant caps.
IRC M1411.6 IMC 1101.10
installed on a floor level that is lower than the next
upstream manhole cover of the public or private sewer shall be
protected from backflow of sewage by installing an approved type
of backwater valve. Fixtures on floor levels above such elevation
Ishall not discharge through the backwater valve. UPC 710.1
Vent all plumbing fixtures through the roof per UPC 906.0 or
with a loop vent per UPC 909.0. Air admittance valves are not
pennitted unless first approved by the Building Inspector on a
case by case basis.
Water heaters installed in attics, attic -ceiling assemblies,
floor -ceiling assemblies or a floor/sub-floor assembly, where
damage may occur from a leak, shall be installed in a watertight
pan made of corrosion -resistant materials. The pan shall have a
3/a" drain and the drain shall terminate in a visible
location. The drain cannot empty into the crawlspace beneath a
building. Discharge from a relief valve into a water heater pan
shall be prohibited. UPC 507.4 UPC 507.5
Access will be required for the whirlpool/jetted tub pump and the
tempering valve for all tubs. The tempering valve may also be
installed at the water heater. UPC 409
Showers shall be a minimum of 900 square inches and be capable
of encompassing a 30 inch circle. The shower receptor shall have
a finished dam, curb, or threshold between 2" and 9" above the
top of the drain. The floor of the shower shall slope a minimum of
1/a" and a maximum of 1/2". Lining materials for built-up showers
and shower seats shall be sloped, extend upward 3" above the
horizontal surface, and over the top of the dam or threshold.
Shower receptors shall be tested by filling with water to the top of
the rough threshold while plugged at the drain. Protect the weep
es in the sub -drain clamping ring from clogging.
JUPC 408.5 - 408.7 1
[9ain building shut-off required on water supply line. UPC 606.2
Pressure reduction valve on main water supply line required by
City code.
Vent hot water tank relief valve directly to the outside.
UPC 608.5
Hot water heater must be seismically anchored or strapped at
points within the upper one-third and lower one-third of its
vertical dimensions. At the lower point, a minimum distance of 4"
must be maintained above the controls with the strapping.
UPC 507.2
All pressure absorbing devices (e.g. air chambers, mechanical
devices, hammer arrestors) shall be accessible or installed per
manufacturer. UPC 609.10
Minimum 1" air -gap required at dishwasher. UPC 414.3
Hose bibs (exterior faucets) are required to have a permanently
affixed anti -siphon device installed. UPC 603.5.7
Soaker and jetted tubs shall be installed and supported per the
manufacturer's installation specifications. UPC 409.6
Dwelling/garage separation shall be maintained by installing 1/2" gypsum
wallboard on the garage side from the foundation to the underside of the
roof sheathing. Ceiling of garages with habitable space above shall have
5/8-inch Type X gypsum wallboard attached with 1-7/8 inch 6d coated
nails or equivalent drywall screws and the structural elements supporting
the ceiling protected with 1/2 gypsum wallboard. Enclosed accessible space
under stairs shall have walls, under -stair surface and any soffits protected
on the enclosed side with 1/2" gypsum wallboard. Water resistant gypsum
shall not be used as a tile backing board where there will be direct
exposure to water, or in areas subject to continuous high hurnidity
(showers, etc.). IRC R302 IRC R702.3.8.1
Fireblocking shall be provided to cut off all concealed draft openings (both
vertical and horizontal) and to form an effective fire barrier between
stories, and between a top story and the roof space. Fireblocking shall be
provided in wood -frame construction in the following locations:
1) In concealed spaces of stud walls and partitions, including furred spaces
and parallel rows of studs or staggered studs as follows:
1.1 Vertically at the ceiling and floor levels.
1.2 Horizontally at intervals not exceeding 10 feet.
2) At all interconnections between concealed vertical and horizontal spaces
such as occur at soffits, drop ceilings and cove ceilings.
3) In concealed spaces between stair stringers at top and bottom of the run.
4) At openings around vent, pipes, and ducts at ceiling and floor level,
with an approved material to resist the free passage of flame and products
of combustion. For additional requirements see IRC 302.11
IDraftstops shall be installed in combustible construction where there is I
usable space both above and below the concealed space of a floor/ceiling
assembly, so that the area of the concealed space does not exceed 1000 sq
ft. and shall divide the space into approximately equal areas. Where the
assembly is enclosed by a floor membrane above and a ceiling membrane
below, draftstopping shall be provided in floor/ceiling assemblies under
the following circumstances:
LCeiling is suspended under the floor framing.
2.Floor framing is constructed of truss -type open -web or perforated
members.
tstopping materials shall not be less than 1/2 inch gypsum board, 3/8
wood structural panels or other approved materials adequately
Drted and installed parallel to the floor framing membersIRC R302.12
ADDITIONAL REQUIREMENTS
ight verification shall be done by the applicant's agent/contractor and
served by the Building Inspector on site. The agent/contractor shall set
the equipment (transit/builders level), establish the datum point, and the
nt of average grade. These items must be consistent with the approved
ns. If the proposed height of a building (as shown on the plans) is
hin 12 inches of the maximum height permitted for the zone, an
vation survey is required. An elevation survey consists of three
nponents to be conducted by a licensed surveyor. 1) Prior to
istruction, the surveyor shall establish average grade as specified in
DC 21.40.030, and shall establish a reference datum point that will be
listurbed and can be freely accessed. 2) The surveyor shall locate the
vation of the first floor prior to the City under -floor inspection. 3) A
al letter of height confirmation shall be provided upon completion of the
�A of EQA,1
H
°z
O
E�
U
�:)V)
Cnz
U
�A
WaW0
z�
H
0 U
CN
2
__ _ _���� Cie. �.- � �, �
V�C-a
9-Id
APPROVE6
RAMS
of — �� � ^ „� . � . N �
JOB
� �.�
o ALL WORK SUBJECT
TO FIELD
INSPECTION F
x
CODE COMPLIANCE E
wc.-e,4
q()o
j
a LP
10
71
15.
o A 7R OVF Djvj�.D
u Z ON
CITY OF EDMONDS BUILDING DIVISION
REVISED P NAPPROVED
G L 0 -5YS Y12— 14b?, PLANS EXAMINER
----------- - -
. . ........ .
ct�l, 60or W-- DATE 11Z
CITY COPY
APR 16 20%
-66 p\
BU,.L,0II1.GDEP.ARTMENT
EDONDS
PlAms A!
<— Z4)' >
Roor ?kpi
14? RR
REV'sco
OC7
i
1421 ctZ.4 &0- 0
ly
E G. co
// /
V-Z�--�6 +5
F Yet g Rolc of blgetlrny
fo whnecr � ersdSt�n•5 5}vrm �Brftr,v + ` p`�,A1 � .� `� � I .Xj
l.eHal �;SbriP$�olt � ~�"
(�
�io AliAt.S LFT>SsMa. till g1. r \-7
a,
10
►C �-
1 n
t�l� +aoo - for � _-: e _ _ _ _--
{�� z� .
.. Etter i ce M wcMe4
ES:
Witt i1V5-bHjl er05folycoh.FroE rzjemeAis AS
NeedecQ der City 5f,1 AArl& CAO.J t
CoA$I'Nc('1'ou �nf}n4Nce.:
Ek'istlytg Avf\10- ny W41 Be-
4- Jt16?SeiQ dos evnhgeto�
Jetl�c�eSr aQ a $t•Avcl 00AStlVrttoA) i�Prve WIN .
43e Yl4DeA okdr if,'Nery k P-j;5. A,r Ivy 919aGaro befit) 61.2.
lter 5"e-5 tatd 8e R40trs to CAtc(k kjs"o
DOWA 51rexd% frva Crnis}rut4�oN Sr+�
Rtfuw ca cojy SfDkml Defiill El 3
{e4 °f 't'y gfac eZle of Ptrt CS {e Be-Cd UefecQ
W l fJfw 2j{ HoutS
Rit M+urW sorts will 6e cdvKpostamaevba4 Per {3MP 15: 13.
PO
FwafTw) lsrAras to 6--
or C044ec{er, to 4ty Well iNStaq ; c Alerder�
prn�Na�e,_wla+er
Wew w�/will
t.
SP AM+ t3{oaECs
-
1 Applicant shill - pair/replace all damage to^
uU,3lcs orfront ;a improvements in City
right-of-way p%Ctiy standards that is caueod
4or occur during the permitted project.
_ 0 1�+.-Pa 14ITl�AGYOVi ru LNb J
1 u E L }GATING ALL ON -SITE lii,t ttES.
f (i'i .li I`_
R UXATIONJREVINN TO = UTILl-li 4"
I .L
. a - L` ff F 11WRE SEON?ATE PER4r45�-. '
...
S
SCt A7
w! _
MOH?NCOR
LOT Svzc gtzq 50a
Eysrsi-l"rl Dwol,r J iclrq
New Ado 604e- qeq !
Ew0a ,n ROD -720
IbTA{ll OSobi
TonpIarJida S CA ko ;
fit5tsi1J 35-5,0
ii)2tn} i 43 S
Nelsill"' Crllos
3 Soz.a� > RJeroV
G Sys. �H g aa.a
a yaV. s? ^Et, HCiO'r T28. 93
New APB ML)AI HT 5Zodn
Ex5Tg f;A 5ZB. 78
ial.�ttliAy ._
Tone. S-� - Corner„�,�Flag�.
Setbacks Ret ui d Actual
Z.—
Sides :2 t?
Other' t r ilh -
Nt�EC
2 9 011
�JAN 773 682 t,,-d URTY COPY
�Ytl1VtNL....- " ttr� 1JNDItil1
OF
�
rOR EROSMI�I (t �TiCL A ID DIM1LACE
oBUILDINODEPARTMENT ..�._ T�-..
il EDMON
APPROVEDENGINEERING RECEIVED IN = to' ""°'"`°°
D BY PLANNING AUG i$ 2017
3072 DEVELOPMENT
COUNT COUNTER SERVICES
SAS"Oer
) 1 q2 oA Elva 1J
v ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
�,-�._,;...:..-�.�.�.,.....-:�.,�:-.•M-:
_
_--------•--
I
s
APPROVED
PLAMS MUSS! BE
ON JOB SM
i
Obtain Electrical Parmitfwn
C'%
I
State Labor&Industries
—
LOT LINE STAKES PdIUST
i j
BE IN PLACE AT TIME OF
FOUNDATION INSPECTION
i
N
'
s
un
I i•• �vJ
�.. ��
„l�l ! '
\J
f
'
1
i1
F
i
Cal
12x8 (dmk poor
as
CITY OF EDMONDS
BUIL I DEPARTMENT
WORK A ( j
ADDRESS `
OWNER
APPROVED DATE: I OAL1 1-1
BLDG.OFFICIAL: A
PERMIT 'NUMBER
+'3.- rcp�.� 20/7 0 7 t
I ll Y C(DIFY
�r
s
s•
.4...N
a
:
lO
!°
Y
't
C-Q
P
qj.
D} Q^'1�•RSx3 wru�
-
shZ�;,hZ 53a71l131swe»
'•j.
I •Roor -Sots+
I I
I fo p.0
�
00,
44
all
CJ
6 '3,,
o
s v)
K-�4
l$xlB x1 p
`
stdoiv
ESU
O
sqc�
.rat � •3 F
G
�
_
�"O W1!-�A"�'Pp�L.i ��tir�f/SO iS j' 17�A A�
729 y�
17 Ol!
u}�
I APPROVED BY: .,
BUILDING DEPARTMENT
CITY OF EDMONDS
V
..2 RECEIVED
SCRLE: DRAWN BY
°ATE' REVE:ED
�{
j
AUG 04 2$17
i
CASPaf Hot)Fho�
CITY Co V
DEVELOPMENT SERVICES
COUNTER
T—.,.NOMB
!
C-w
C7
Pi- C,
f ".3
'Ph 6
Clod
790 1 felu kCA4 eS 4,94V PD JA'U;
iv PJAM;
Din
+IFZ
-Tood Alt-
BAr
AW6%
(MY"
pm
U
1J
R
RESUB
nrT 17
-,�V 6.oz
" g qo)(o S(,-6ef
Ulf
BUILDING DEp" CrryoFEDAMOZNT
Roar
5CALE: ....... BY: DRAWN BY
DATE: REVISED
Lt 2 ct2,4 P,,W- W
I
SHEAR HALL 5CHrzr;)ULr=
PER 2015 ISG
GENERAL NOTE5:
-
SEE PLANS TO DETERMINE THE DIFFERENT DESIGNATORS FOR SHEAR WALL MATERIALS,
NAILING, ANCHOR BOLTS, AND HOLDONNS. LOCATE HOEDOWNS A5 GL05E A5 POSSIBLE TO THE END
-
OF THE DE-51CNATEP WALL.
-
ALL T HOLLDDO LANGHO DBOLTS, WASHERS, 4 NAILS IN CONTACT WITH P.T. WOOD TO BE
ANN�I
PI = ONE SIDE PLYWOOD
P2 = TWO SIDE5 PLYWOOD
..
MARK
PLYWD.
NAIL SPADING
EDGES FIELD
OP 4 BTM.
PLATES
ANG
II
BLKG.
REQO.
SILL
PLATE
HOR BOL
OPTIONAL
SIMPSON MA
ANGHOR5
BASE
PLATE
NAILING,
HEM FIR #
VALUE
M&H
PI-b"
8d
6"
12"
6"
15" O.O.
2x4
5/8" 0 48"
0 48" 4ENDS
(2) I6d o 10"
240
-
ROOFING MATERIAL
FINISH PER ELEVATION
PI-4'
8d
4"
12'
4'
I6. OA.
2x4
5/8' 0 32•
0 30• 4 ENDS
(2) I6d 07
349
- ON T/I6" OBS SOLID GDX 24-0 PLYWOOD
SHEATHING; bd o 6.0.G. EDGE.
PI-5' **
8d
3'
12"
3"
14" O.G.
(2) 2x4/6
5/8' 0 24'
0 24" 4 ENDS
(2) I6d o 5"
450
1-2-1
8d
2"
12"
2'
12' O.O.
(2) 2x4/6
3/4" 0 24'
0 18' 4 ENDS
(2) I6d 0 5"
585
8d o 12' O.G. FIELD
055 ACX PLYWD o EVES)
MIN. I5# UNDERLAYMENT
P2-6' **
Bd
b'
I2"
6'
10" OZ.
(2) 2x4/6
"" 0 24°
WA
(2) I6d 0 5"
480
p2�• **
8d
4°
12'
4'
8' O.G.
(2) 2x4/6
B/4" 0 20"
WA
(3) I6d 0 5"
700
NAIL W EDGE, 12' FIELD
WITH 8d NAILS, U.N.O.
P2-3' **
ad
3•
12'
3°
e' O.G.
W 2x4/6
3/4" 0 Ib"
WA
(4) Ibd ®5'
900
24° CARDBOARD BAFFLE
P2-2' **
bd
2"
12"
2'
W dA.
0 2x4/6
3/4" 0 12"
WA
(4) I6d 0 4"
1110
ALLOW FOR 1' AIR SPACE
-.
**NOTE, WALLS WITH UNIT SHEAR OF 350#At. OR GREATER 514ALL HAVE FRAMING
MEMBERS (STUDS 4 PLATES) ABUTTING PANELS NOT LE55 THAN 3X MEMBERS OR (2) 2X MEMBER5
PER IBC 2015 AND 5DPW5-2008
MIN. EXTEND 12° ABOVE
INSULATION.
- - Z
SOLID SHEATHING -
PER SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC, CHAPTER
CD
N#iERE EXPOSED
- GfYON; !2j'ZX'MEFEER�RRL"OK-INYi
(V MEMBERS
TO WEATHER
STITCH NAIL DOUBLE 5TUD5 AND PLATES TOGETHER WITH
I6d NAILS 0 12" O.G. 5TA6ERRED ON THE STUD FACE
TOP PL.
I. USE POWER -DRIVEN STEEL STUDS AND NAILS BY HILTY OR RAMSET WHERE APPLICABLE.
IX FASCIA BD.
W METAL
GUTTER -
2. PLYWOOD MAY BE INSTALLED EITHER HORIZONTALLY OR VERTICALLY.
5. SOLID BLOCK WITH J015T UNDER INTERIOR SHEAR WALLS.
- APPROVED TRUSSES BEARING
MANUFACTURER'S 5EAL. SHEAR WALL NOTES
- SEE ROOF FRAMING PLAN
-
FOR SPACING I/16° OSB OR PLYWOOD SHEATHING USE bd COMMON OR GALVANIZED NAILS. BLOCK ALL PANEL
EDGES. LONG DIMENSIONS OF PLYWOOD MAY BE INSTALLED VERTICALLY. NAIL 0 12' O.G. TO ALL
IHLSUAATE PER WSEG INTERMEDIATE STUDS WHERE 3' NAIL SPACING 15 SPECIFIED AT PANEL EDGES, USE 1-Il2" 8d
- SHORT HAILS OR 3X STUDS WITH Bd COMMON NAILS FOR 2" NAIL 5PAGING 115E 3X STUDS
' 2X BIRD ELK'& W/--
- -
2"4' SCREENED VENT
HOLES WITH 1/4'
CORROSION RE515TANT
LIVING
' METAL MESH COVERING
_
.AREA
'
-
FIRE BLOCK ALL VERTICAL
i
OPENINGS IN WALLS AT
PLATES AND FLOORS
FLOOR JOISTS, SIZE AND
PER PLAN
FIN. FUR__
ZSPACING
AND STAGGER PANELS. WHERE PLYWOOD 15 2 SIDES OF WALL JOINTS TO FALL, ON
SEPARATE STUDS ON EACH SIDE.
FLOOR PLYWOOD - USE 8d COMMON NAILS 010" O.G. AT INTERMEDIATE SUPPORT5, W O.G.
AT ALL PANEL EDGES AND WOG. AT ALL S1EA R WALLS, UNLE55 OTHERWISE SHOWN ON PLANS.
FLOOR JOISTS - J015T PARRALLEL TO FLOOR OPENING5 AND EXTERIOR WALLS SHALL BE
GROSS BLOCKED AT 48" O.G. o EDGES NV (4) IOd NAILS FOR THE FIRST BAY.
3' x 3' x 1/4" SWARE WASHERS AT ALL ANCHOR BOLTS. PLATE WASHER5 TO BE INSTALLED WITHIN
I/2" OF SHEATHING
1/16" 055 OR PLYWOOD SHEATHING - STAPLE SCHEDULE
ALLOWABLE SHEAR VALUES WITH HEM FIR #2 STUDS
21116 GA. STAPLES 0 15 GA. STAPLES 0 14 GA. STAPLES 0
3. O.G. - 280 #/ft. 4" O.G.-280#/ft. 4" O.G. - 303#/ft.
2. O.G. - 360#/ ft. 2-I/2. OG. - 430#/ft. 5" O.G. - 340#/ft.
4° O.G. AND IOd NAILS 2. O.G. - 504#/ft.
0 6. O.G. - 620#At.
FIELD SPACING. 12" O.G. NAILS 4 STAPLES.
HOEDOWNS - INSTALL 51WWN HOLDOWN5 OR EQUIVALENT AT THE END OF SHEAR WALL5
WHEN SHOWN ON DRAWINGS. TO ATTACH U5E 2X OR 3X HF #2 CONSTRUCTION GRADES AS
SHEAR HALL BOUNDARY ELEMENTS. HCLDOWNS ARE ONLY REQUIRED WHERE 5140WN ON PLANS.
6. ALL GUARDRAILS PER MANUFACTURERS -
SPECIFICATIONS. SUPPORTS CAPABLE OF
10. UNDER ALL PARALLEL BEARING WALLS USE DOABLE
RESISTING A SINGLE CONCENTRATED LOAD
J015TS OR 'A NOTED ON PLAN, DOUBLE -1015T5
GENERAL NOTES
OF 200 POUNDS, APPLIED IN ANY DIRECTION
TINDER ALL NON -BEARING PARALLEL WALLS
AT ANY POINT ALONG THE TOP OF THE RAIL.
I. - ALL EXTERIOR WARM WALLS TO BE 2.6 STUDS
16' O.G. TYPICAL, HITH R-21 INSULATION.
T." TUB/SHOINER UNITS SHALL HAVE FIRE BLOCKING
11. WHOLE HOUSE INDOOR VENTILATION 5YSTEM WITH
24 HOUR PROGRAMMABLE TIMER, RETURN AIR
BETWEEN WALL STUDS AND WATERPROOF
TO BE SUPPLIED BY HEATING 5Y57E3-1.
2. ALL HEADERS ON UPPER FLOOR TO BE 4x8
DOUGLAS FOR #2 UNLESS NOTED OTHERWISE.
`-+URROING TO �-12' FROM DRAIN. GLAZING,
INCLUDING WINDOWS WITHIN +T2" OF DRAIN, SHALL
_
- 12. MAX. HOT WATER TEMP. DISCHARGING INTO A
BE SAFETY GLASS. SHOWER FLOW 15 LIMITED TO
BATHTUB OR WHIRLPOOL BATH SHALL BE LIMITED
3. FUR -OUT HEADERS TO MATCH 2.6 WALLS.
25 GAL/MIN. WOOD FRAMING TO BE PROTECTED
TO 120"F. THE WATER HEATER SHALL NOT 13E
FROM WATER SPLASH AND MOISTURE.
CONSIDERED A CONTROL FOR MEETING T1415 PROVISION.
4. PROVIDE SOLID BLOCKING UNDER ALL
BEARING WALLS. -
8. ALL BATHROOM FANS, KITCHEN HOODS, AND DRYER
IN
15. ALL OPENINGS MADE IN WALLS, FLOORS, OR CEILINGON S
DUGT5 SHALL BE EXHAUSTED THRU THE ATTIC TO THE
FOR THE PASSAGE OF PIPES, STRAINER PLATES
S. INLINE FRAMING -.SINGLE TOP PLATE STRAP
ROOF OR THRU THE FLOOR SYSTEM TO AN OUTSIDE
DRAIN INLETS, AND METER BOXE5 SHALL MEET THE
a 5MIGE-5 AND CORNERS, EXCEPT AS NOTED
WALL ALL WALL DUCTS SHALL TERMINATE AT LEAST
REOUIREMENTS OF THE 2015 UPO SECTION 513.12
FOR SHEAR TRANSFER
-
36" FROM A WINDOW OPENING.
14. ALL FLASHING TO BE IN COMPLIANCE WITH
-
I 9. ONE WINDOW PER BEDROOM SHALL MEET
2015 IRG, SECTION RT03.4.
EGRESS CODE PER 2015 IRC R310.1
6CAerAI:
0 19il exf-eg,aR wArrn wmis {-o Pe Zx6 SlWs
IV' d.e, +Yp w./ R-2l ir4sv14, dw
(� All 4*AOer A-o L46 t-l)elo b '#Z. t!/l1es5
DiH2WlSe YUo+E LZ_ I
FTwslr)ers i N COAilv-} In9lfrta,*3 Illmder
s iiPrlt 8� 1-107- b3Pped GA(v SjC, j
I AU
6rerg6e -f'1tpe4 d 'n000e"(
®, =rvsut,4fe ail tvRrm tv►�ifS A�+f(l ,`jJk
SH rtfiir �xfer;vr N11" A) SHAM s
All trs s 8ieot sloaKs "t0 Be.
CQ '7/1b asB -5KE fnrj
tl�:^° 7//4 o5B All w/9l l e,,w+ sHewHAs.
Nu 14oles brltte4 TIN wAlt i'iAieS 431.11 'Be
ire �1ucK� w�-r'pAv#1 ``
,() fly "t'oc- Svg-Floe
i
63 NorricAAe cljp5 ow rrlt -Mvssei its Plfi4e W'
SACr;er tA)S+A((Cd, to -tap o-F GafiA)qS°
ft s0i5t vnper QlVma'tr5 WM( ;Notusef.
ok COA 0005 R 6ye Os ✓4 Ai' wool Ribyes. 2W'w
��? -Qa0�r4A� S�IR1l TNIp°tcl+ EYSi3'{">,� �re$i(itttJfjgl '
RSpNgtt {IGry�i vy ProAtul+ i+v color .44 5losair. z
t n 1
YnEfnt Y9tfelr s�laduvF' iA7 ,�0o-rfAaJ+ vAttry:�
IQ UAW -P&P Io 8e bVvfea( ftfry +++,tt +o
F �-OOf Sr}tic VeA.'i- 9
RECEIVED
AUG 04 2017
Coogsper A -A i+-olj
(2) 2x TOP PLATE, LAP CORNERS,)
OFFSET END JOINTS BY 45"
_W 055. OR PLYND. SHEATHING.)
NAIL 6" EDGE, 12" FIELD WITH 5d
NAILS UNLE55 NOTED OTHERWISE/
2x 5TUD5 a 16" O.G. TYP.J
SIDING, SEE PLAN FOR TYPE
2x BOTTOM PLATE
FIN. FLR.
2x RIM JOIST-
2x P.T. 51LL—
z_
4"m D.S. TIGHTLINE, POSITIVE
DRAIN TO STORM SYSTEM
GRADE TO SLOPE -
,Y FROM BUILDING
Z
a� %Z`"
c
4"A PERF. FOOTING DRAIN TILE
W/ CLOTH COVER d GRANULAR
COVER AS REOb. BY SOIL
CONDITIONS /
WpN 10" ANCHOR BOLT W/3'X3"X 1
1/4" PLATE WASHERS a 46" oz. NO -
LE55 THAN 4)z' 4 NO MORE THAN 12' I
FROM EA END SILL CORNER, JOINT,
END, OPENING ETC. T" MIN.
EMBEDMENT INTO CON-. EXCEPT a .1
SHEAR WALLS - SEE 5HEAR WALL
NAILING 5GHEDULE.
2x P.T.
i II - #4 GONT. HORZ. TOP
F
I
R
#4 STUB UP a 4&' O G.
T
WV STD. HOOK
EXTEND 14" MIN. INTO WALL
3' MIN.
#4N O.
GLR TYP.
FODATION N
7ALL
SPLEA
O/FDN. IZ
OOTINGS TO BEAR ON
FIRM UNDISTURBED. 501L
WALL GREATER THAN 4b" PER PLAN
eST17. FOUNfl,4TION �7ETAIL
si" GYPSUM WALLBOARD, TYP.
WPVA VAPOR BARRIER a WALLS GI SCALE: KTS. PER IRG R403.15 #5
AND CEILINGS
LIVING AREA
FIRE BLOCK ALL VERTICAL
OPENINGWAL 5 IN L5 AT
PLATES AND FLOORS
T"X 10" ANCHOR BOLT W/ 3"X3"X v4
PLATE WASHERS a 46" o NO LE55
THAN 4�" 4 NO MORE THAN 12"
FROM EA. END SILL CORNER, JOINT, -
END, OPENING ETC. T" MIN.
EMBEDMENT INTO GONG. EXCEPT WV T46 PLYWOOD SUB -FLOOR
SHEAR WALL5 - SEE SHEAR WALL (GLUED s NAILED) NAIL 6' EDGE,
/— NAILING SCHEDULE. —12* FIELD W/ IOd NAILS.
qL1
- GRANLSFACE `INSLULATE PER WSEC
45" MAX. SEE FOUNDATION PLAN
UNBALANCED FOR BEAM SIZE 4
(TALLER WALLS PER PLAW POST SIZE / SPAGING
90# FEL'
6 MIL. POLY VAPOR BARRIERLL
REINFORCEMENTUST
tF5-EE
BE TIED IN PLAGE
OR FOUNDATION IN5PEGITON
UNDATION PLAN
FOR FTC. / FDN. 51ZE
ALL FOOTINGS TO BEAR ON PROVIDE DRAIN AT LOW
FIRM UNDISTURBED 501L POINT OF CRAWL SPACE
2. SOLID BLOCKING a
BRG. WALL ABOVE TYP.
—FLOOR JOISTS, SIZE AND
5PAGIN5 PER PLAN
Z
2x4 GUSSET EA SIDE
'SIMPSON"
d)
COW-
P05T TO ONC. _
<
a
N
5WARNALL PER PLAN
TkiD HOLDOWN PER PLAN
3/4" MIN T46 PLYWOOD Wf3+LOOR
GLUED 6 NAILED - NAIL # V EDGE
6 12' FIELD W IOd NAILS
FLOOR JOIST
PER PLAN BOTTSIgAR WOM PLATE NAILNS
� ALL SGIiDILE
P.T. SILL PLATE W
lIrIlOR BOL15 PER
SFEAR WALL SGFEDIILE W
3'x3'xl/4° 50. Wh5I�25
N #4 CCW. TOP
FINISHED 6RADE
#4 VERT. BAR # 48" O.G. W
5TND. HOOK EXTEND 14' MIN. Z
INTO STEM WALL
(r
:..----M#4-COW. TOP-- ---..: -.- ----- --
r
13"
4 STHD HOLDOWN g FOUNDATION
SGAL19: N.T.S.
GARAGE / LIVING SEPARATION
TYPE "X" GYPSUM WALL BOARD
AT CEILING / WALL
GARAGE
�V.79mv_ REM
4" CONC. SLAB ON
4" GRANULAR BED
DETAIL PI.+,G PPlZ
DETAIL oZ ABOVE
SEE FOUNDATION PLAN
FOR PAD SIZE TYFICAL WALL SECTIONS --- --
ALL FOOTIN65 TO BEAR ON
FIRM UNDISTURBED 501L GI SCALE: N.T.S.
O#OWN BY
RECEIVEDCOTE: VISEU
AUG 04 2017 l _A5e