Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2021-0656_Manufacturer_Specifications_and_Installation_Instructions_5.11.2021_2.36.57_PM_2190865
Amoffeao S*vd"do HEATING & AIR CONDITIONING Submittal Split System Cooling 4A7A4060L1000B Note: "Graphics in this document are for representation only. Actual model may differ in appearance." TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. November2019 4A7A4060L-SUB-1 D-EN J*# Ingersoll Rand, AAWc O Sluida,f HEATING & AIR CONDITIONING SERVICE PANEL ELECTRICAL AND REF COMPONENT CLEARANC PER PREVAILING COD TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 152A (5 FEET) ABOVE UNIT. UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 305 (12") FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED. ELECTRICAL SERVICE PANE L� 22.2 (7/8) DIA. HOLE LOW VOLTAGE 28.6 (1-1/8) DIA. K.O. WITI 22.2 (7/8) DIA. HOLE IN CONTR01 BOX BOTTOM FOR ELECTRICAI POWER SUPPL' K 25 (II A i r H F G I-ft E.V. rvK ALURNATE t� ELECTRICAL ROUTING LIQUID LINE SERVICE VALVE, "E' I.D. FEMALE BRAZE CONNECTION WITH 1/4" SAE GAS LINE 1/4 TURN BALL SERVICE VALVE, 'D" FLARE PRESSURE TAP FITTINGS. I.D. FEMALE BRAZED CONNECTION WITH I/4' SAE FLARE PRESSURE TAP FITTING. Model Base A B C D E F G H J K 4A7A4060L 4 943 (37-1/8) 946 (37-1/4) 870 (34-1/4) 7/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 508 (20) SOUND POWER LEVEL Model A -Weighted Sound Power Level [dB(A)] Full Octave Sound Power [dB] 63 Hz* 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4A7A4060L 71 81 72 69 69 66 60 57 54 Note: Rated in accordance with AHRI Standard 270-2008 *For reference only 4A7A4060L-SUB-1 D-EN AAWc O Sluida,f HEATING & AIR CONDITIONING Product Specifications OUTDOOR UNIT (a) (b) 4A7A4060L1000B POWER CONNS. — V/PH/HZ (c) 208/230/1/60 MIN. BRCH. CIR. AMPACITY 27 BR. CIR. PROT. RTG. — MAX. (AMPS) 45 COMPRESSOR DURATIONW- SCROLL NO. USED — NO. STAGES 1 — 1 VOLTS/PH/HZ 208/230/1/60 R.L. AMPS (d)— L.R. AMPS 20.8 — 127.1 FACTORY INSTALLED START COMPONENTS W NO (Uses BAYKSKT263) INSULATION/SOUND BLANKET NO COMPRESSOR HEAT NO OUTDOOR FAN PROPELLER DIA. (IN.) — NO. USED 27.5 — 1 TYPE DRIVE — NO. SPEEDS DIRECT— 1 CFM @ 0.0 IN. W.G. (f) 4340 NO. MOTORS — HP 1-1/5 MOTOR SPEED R.P.M. 835 VOLTS/PH/HZ 200/230/1/60 F.L. AMPS 1.05 OUTDOOR COIL — TYPE SPINE FIN- ROWS—F.P.I. 1-24 FACE AREA (SQ. FT.) 24.93 TUBE SIZE (IN.) 3/8 REFRIGERANT LBS. — R-410A (O.D. UNIT) (g) 7LBS., 10 OZ FACTORY SUPPLIED YES LINE SIZE — IN. O.D. GAS (h) 7/8 LINE SIZE — IN. O.D. LIQ. 3/8 CHARGING SPECIFICATIONS SUBCOOLING 10°F DIMENSIONS H X W X D CRATED (IN.) 42.4 x 35.1 x 38.7 WEIGHT SHIPPING (LBS.) 246 NET ( LBS.) 211 4A7A4060 L-SUB-1 D-E N (a) Certified in accordance with the Air -Source Unitary Air -conditioner Equipment certification program, which is based on AHRI standard 210/240. (b) Rated in accordance with AHRI standard 270. (c) Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers or fuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. e> Use start components only when compressor is found to enter locked rotor condition and will not start or when lights dim at compressor start. No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter. Optional kit shown. M Standard Air — Dry Coil — Outdoor (g) This value approximate. For more precise value see unit nameplate. (h) Max. linear length 60 ft.; Max. lift — Suction 60 ft.; Max. lift — Liquid 60 ft. For greater length consult refrigerant piping software Pub. No. 32-3312-0* (* denotes latest revision). 4&eficaw Siuida rd, HEATING & AIR CONDITIONING Mechanical Specification Options General The outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit, ten (10) feet of tested connecting line, and the smallest rated indoor evaporative coil match. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 1995. Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather -resistant powder paint finish. The corner panels are prepainted. All panels are subjected to our 1,000 hour salt spray test. Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and low and high pressure switches. A factory supplied, field installed liquid line drier is standard. Compressor The compressor features internal over temperature and pressure protection. Other features include: Centrifugal oil pump and low vibration and noise. Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured, this system has a cooling capacity to 55°F. The addition of an evaporator defrost control permits operation to 40°F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 30°F. The addition of the BAYLOAM107A low ambient kit permits ambient cooling to 20°F. Thermostats —Cooling only and heat/cooling (manual and automatic change over). Sub -base to match thermostat and locking thermostat cover. 4A7A4060L-SUB-1 D-E N (V"im?Ingersoll Rand. Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands —including Club Car@, Ingersoll Rand@, Thermo King@ and Trane®—work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and efficiency. We are a global business committed to a world of sustainable progre ss and enduring results. �® Rand T THERMO KING ch TALWE® ingersollrand.com C UL US LISTED The AHRI Certified mark indicates Ingersoll Rand participation in the AHRI Certification program. For verification of individual certified products, go to www.ahridirectory.org. Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. 4A7A4060L-SUB-1D-EN 12Nov2019 Supersedes 4A7A4060L-SUB-IC-EN (July2019) ©2019Ingersoll Rand