BLD2019-1579 (2)ua Type: MECHANICAL Owner/ Business: HAMILTON LYNN C Status: ISSUED Subtype: COMMERCIAL MECHANICAL Parcel No: 00434202102900 Site Address: S19 MAIN ST EDMONDS,WA 98020-3149 Applied: 12/13/2019 Subdivision: 004342 Lot: 0 Issued: 1/28/2020 Fire Sprinklers: Lot Area: Zoning: Final: Valuation: $0.00 Occupancy Type: Construction Type: Expiration Date: 7/26/2020 Code Edition: 0 No. Stories: 0 # of Dwelling Units: 0 Issued by: NED Scope of Work: LEFTCRAFT - INSTALL 2 WALK IN COOLERS WA State Contractor L & I #: WILCOC"194Q0 City of Edmonds Business License #: 602454996-001-0001 CONTACTS NAME TYPE NAME ADDRESS PHONE EMAIL APPLICANT NW RESTAURANT SERVICES 14910 AURORA AVE N, (360)202-7115 GDBELCHER@GMAIL.COM SHORELINE WA98133 BUSINESS LEFTCRAFT 519 MAIN ST, EDMONDS WA (206)931-4574 TRAVISEATON@COMCAST. NET OWNER 98020-3149 CONTRACTOR WILCOX CONSTRUCTION 234 STH AVE S, EDMONDS WA (425)774-4185 98020- 170 FAIRBREEZE DR, PORT OWNER HAMILTON LYNN C TOWNSEND WA98368 FEE INFORMATION DESCRIPTION ACCOUNT AMOUNT PAID PAID DATE RECEIPT # 1 - BASE FEE FOR MECHANICAL 001.000.322.10.000.00 $40.00 $0.00 PERMITS BASE FEE FOR MECHANICAL 001.000.322.10.000.00 $40.00 $0.00 PERMITS CITY TECHNOLOGY FEE CHARGED 001.000321.99.100.00 $35.00 $0.00 PER PERMIT HOODS TYPE 1 OR 2 OR FUME 001.000.322.10.000.00 $100.00 $0.00 HOOD INCLUDING DUCTS MECHANICAL PLAN REVIEW FEE 001.000.322.10.000.00 $2S0.00 $0.00 MECHANICAL PLAN REVIEW FEE 001.000.34S.83.000.00 $100.00 $0.00 MISC MECHANICAL EQUIPMENT 001.000.322.10.000.00 $20.00 $0.00 FOR WHICH NO FEE IS INDICATED TOTALS: $585.00 $0.00 CONDITIONS CONDITION TYPE STATUS I NOTES Printed: Tuesday, January 28, 2020 9:30:25 AM 1 of 4 Printed: Tuesday, January 28, 2020 9:30:25 AM 2 of 4 MECHANICAL Permit • City of Edmonds Ave:rBLD2019-1579 •. Applicant on behalf of his or her spouse heirs assigns and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, HOLD HARMLESS FOR employees, and agents from any and all claims for damages of whatever nature, arising INFORMATION directly or indirectly from the issuance of this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. Installation, use and maintenance of equipment and components shall be per MANUFACTURER SPECS FOR manufacturers specifications, installation instructions, and applicable state codes. INFORMATION Provide manufactures installation instructions on site for Building Inspector. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly visible from the street POST ADDRESS FOR or road fronting the property. Address numbers shall be Arabic numerals or alphabet INFORMATION letters Numbers shall be legible from the public way, at least 4 inches high with a half inch min stroke width on a contrasting background. SEPARATE PERMIT REQUIRED FOR Separate Permit Required For: NFORMATION Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of SOUND OR NOISE FOR 7:00am to 6:00pm on weekdays and 10:00am to 6:00pm on Saturdays, excluding Sundays INFORMATION and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120 INSPECTIONS COMPLETED RESULT SEQID INSPECTION TYPE INSPECTOR NOTES DATE B-3 MECH ROUGH IN B-5 MECH FINAL" OTHER - BUILDING B-4 FRAMING Printed: Tuesday, January 28, 2020 9:30:25 AM 3 of 4 Printed: Tuesday, January 28, 2020 9:30:25 AM 4 of 4 '.,7C. 1 Sy - BUILDING PERMIT APPLICATION Permit #: �l j��J D1Q , 1'5 Development Services V�/ ` Building Division 121 Sth Ave N / Edmonds, WA 98020 425.771.0220 For handouts, submittal requirements, permit status and inspection scheduling information go to: www.edmondswa.gov. PLEASE NOTE: Intake appointments are required for New Single Family Residences, Large Additions, ADU's, New Commercial, and Major Tenant Improvement application submittals. If plans are prepared by a profession- al, electronic files are requested in addition to the hard copies. Please bring electronic files on a flash drive or coordinate for electronic transfer. Please ca11425-771-0220 to schedule an intake appointment! JOB SITE INFORMATION/LOCATION: (Where the work is taking place) Job Site Address: �l `%,✓J-�y, �ivzr�� Parcel: Lot /Unit/Suite #: Subdivision: PROPERTY OWNER: &Z - TName: Mailing Address: City/State/Zip: Phone #: Email: OWNER INSTALLATION: *If yes, read and sign* Will work be performed by the property owner? ❑ Yes )i No I own, reside in, or will reside in the completed structure. This installation is being made on property that I own which is not intended for sale, lease, rent, or exchange according to RCW 18.27.090. Owner Signature: APPLICANT / CONTACT INFORMATION: Name of Applicant: N t? 1_,9>4-4w/y44•- Mailing Address: / 1- l.10 , 2�� ✓�U�G%i� City/State/Zip: 4,� ! / 3-3 Phone #: 3Z,,p 20 °Z'%lJ E-mail: GENERAL CONTRACTOR: (If different from applicant) General Contractor: 1,62 4 l L'J W Mailing Address: n ;! City/State/Zip: Phone #: E-mail: �I l� STATE UBI M nD Z 9 -7 `7 l0 CITY OF EDMONDS BUSINESS LICENSE #: WA STATE CONTRACTOR L & I #: (CCB) & EXPIRATION DATE: �9/'- N U }Q 5 K1i :Z ,� a /7.-2 -2'o TYPE OF PERMIT (Provide Details on ..- ❑ Accessory Structure) ❑ Addition Detached Garage ❑ Demolition �Iwechanical ❑ New Single Family / Duplex ❑ Plumbing ❑ Fire Sprinkler ❑ Remodel ❑ New Commercial/ Mixed Use ❑ Re -Roof ❑ Signs ❑ Tank ❑ Tenant Improvement ❑ Other Remodel Permit fees are based on: The value of the work performed. Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the work indicated on this application. Valuation: PROPOSED NEW SQUARE FOOTAGE FOR THIS APPLICATION Basement sq ft: Finished ❑ Unfinished ❑ 1st Floor, sq ft: 2nd Floor, sq ft: Garage/Carport:, sq ft: Deck/Covered Porch/Patio: Other sq ft: PROJECT DESCRIPTION I certify that the information I have provided on this form/application is true, correct and complete, and that I am the property owner or duly authorized agent of the property owner to submit a permit application to the City of Edmonds. � Print Name: CA%'f 72:ad Signature: Dat/7 �c�� GENERAL• DATA Occupancy Group(s): Occupant Load(s): Type(s) of Construction: �,ow Fire Sprinklers: Yes ❑ No ❑ WA STATE ENERGY CODE: If your project affects the building envelope, mechanical systems, and/or lighting, you must complete the appropriate WSEC forms. DEFERRED SUBMITTALS: All commercial building permits that will require associated plumbing, mechanical, fire sprinkler, and/or fire alarm permits are applied for separately. TI / CHANGE OF USE / NEW BLDG: Include TRAFFIC IMPACT worksheet MECHANICAL EQUIPMENT COUNTS, Relocated) BTUs Gas / Elec / Other Qty A/C Unit/Compressor Air Handler /VAV Boiler Dryer Duct Exhaust Fans Fireplace Furnace Heat Pump Unit Hydronic Heating Roof Top Unit (Provide eleva- tions if a Commercial Bldg) Other: PLUMBING FIXTURE COUNTS• . or .. Qty QtY Clothes Washer Tub/ Showers Dishwasher Backflow Device (RPBA, DCDA, AVB) Drinking Fountain Pressure Reduction/ Regulator Valve Floor Drain/Sink Refrigerator Water Supply Hose Bibs Water Heater - Tankless? Y or N Hydronic Heat Water Service Line Sinks Other: Toilets Other: GAS/FUEL CONNECTION COUNTS (New, Relocated or re -piped) BTUs Qty BTUs Qty A/C Unit Outdoor BBQ/ Fire pit Boiler Stove/Range/Oven Dryer Water Heater Fireplace/ Insert Other: Furnace Other: MEDICAL GAS, AIR VACUUMCOUNTS Relocated or • • Qty Qty Carbon Dioxide Nitrous Oxide Helium Oxygen Medical Air Other: Medical - Surgical Vacuum Other: DEMOLITION Type of structure to be demolished: Square footage of structure to be demolished: AHERA Survey done? Y / N PSCAA Case #: Critical Areas Determination: Study Required ❑ Conditional Waiver ❑ Waiver ❑ Fill in Place ❑ Fill Material: Removal ❑ Size of Tank (Gallons) Critical Areas Determination: Study Required ❑ Conditional Waiver ❑ Waiver ❑ GRADE/FILL/EXCAVATE Grading: Cut cubic yards Fill cubic yards Cut / Fill in Critical Area: Yes ❑ No ❑ GENERALPROVISIONS APPLICATIONS: Applications are valid for a maximum of 1 year. ESLHA Applications, 2 years. LICENSING: All contractors and subcontractors are required to be licensed with Washington State Department of Labor & Industries and have a current City of Edmonds Business License. CITY COPY 'M 1094' CONCEALED MOUNTING COMPONENT 1094 SUREC1ASE HYDRAULIC DOOR CLOSER ■ Powerful gas -loaded hydraulic cylinder guarantees controlled closure. ■ Exposed and concealed mounting models. ■ Patented solid steel enclosed housing and bend -resistant hook assure Ion g wear in heavy use. ■ Extra -wide hook ensures roller pick-up and overcomes align ment problems. ■ Life -cycle tested to operate reliably even after a half -million closures. ■ Easily replaces any conventional door closer. ■ Kason walk-in hinges and latches where self -closing doors with controlled closure are needed. ■ Mounting slots on hook allow for easy adjustment to compensate for door sag, keeping roller aligned with hook for proper func iion- CONCEALED FLUSH 2 E3.5 2 2 '� .e 58.6 ins C a L �r a , A 9� fi •: 2 i59.5 60 *,--1 1094 --{ J EXPOSED MOUNTING COMPONENT U.S. Trademark: 3,212,100 Hook said separately. EXPOSED OFFSET 35% o o e 22.2 5_. 7�7.2 6 761.3 O ils 33.5 All the features of the 1094 Sure- Model No. Item Finish Wgt/Carton 11094000002 Closer, Exposed Mounting Brushed Chrome 35 lb. (I 5.6kg) Close, with the additional benefit of a specially developed snubbing mechanism. Initial fast closing action 11094000003 Closer, Exposed Mounting Polished Chrome 35 lb. (I 5.6kg) 11094000012 Closer, Concealed Mounting Brushed Chrome 35 lb. (I 5.6kg) allows unit to withstand slamming force, while secondary, slower action provides gradual closing to lessen 11094000013 Closer, Concealed Mounting Polished Chrome 35 lb. (I 5.6kg) 11094S00003 Dual Closer, Exposed Mounting Polished Chrome 35 lb. (I 5.6kg) final impact. SPECIFICATIONS 11094S00012 Dual Closer, Concealed Mounting Brushed Chrome 35 lb. (I 5.6kg) 11094S00013 Dual Closer, Concealed Mounting Polished Chrome 35 lb. (I 5.6kg) MATERIAL MOUNTING: Heavy ggauge Holes drilled for steel. &using No. 10 (5.0 mm) and hook also screws (included) available in 11094000093 Stainless Steel Closer, Concealed Mounting Satin 35 lb. (15.6kg) Adjustable Wide -Hook Flush to 3/4" 11094000026 (0.0-19.1 mm) Offset Satin 10 lb. (4.5 kg) 11094000027 Adjustable Wide -Hook, 7/8"-1-5/8" (22.2-41.3 mm) Offset Satin 13 lb. (5.9kg) stainless steel PACKAGING: Closers and FINISH: hooks packaged Polished or separately; 24 to brushed chrome, a carton stainless steel, or powder coat WEIGHT-11094000927 See order 11094000926 Adjustable Stainless Steel Wide -Hook, Flush to 3/4" (0.0-19.1 mm) Offset Satin 10 lb. (4.5 kg) Adjustable Stainless Steel Wide -Hook, 7/8"-1 5/8" (22.2-41.3 mm) Offset Satin 13 lb. (5.9kg) information PAGE 13- 58 WALK - IN © 2016 Kason Industries, Inc. `�� MM , � JAN 13 2U23 a`IY OF EUViOND.S U.S. Trademark: 2,415,070 CNS 1 U.S. Trademark: 2,415,066 SPRING ASSISTED HINGES ■ Spring mechanism adds extra closing force to overcome air ■ resistance on heavy walk-in doors. ■ Special high -lift cam system outperforms similar spring hinges. ■ Cam -rise action reduces gasket wear, even with irregular floors. ■ Built-in dwell holds door open beyond 120°. ■ Simple manual operation reverses hinges for use on right - or left -opening door. Optional set screw at back of strop to prevent lift off of door. I"'WO` O 2017 Kason Industries, Inc. SPECIFICATIONS MATERIAL: LOAD RATING - Hi gh pressure die-cast zinc with See Hinge Selector Chart, Page self-lubricating nylon cam 824, Group D FINISH: See table to right. Powder coat also available PACKAGING- 6 each MOUNTING: Drilled and countersunk for 1/4" (6.Omm) flat head screws. OPTION: Also available in non -lift off and non -spring models. Not recommended to use 1248 spring loaded with 1245 non -spring loaded hinges WEIGHT: 1248: Approx.19.5 lb. (8.85kg) per carton 1249 Approx.13 lb. (5.9kg) per carton CONTINUED ON FOLLOWING PAGE WALK-IN PAl�4� 3 2020 134 IEPA" E!Vr CONTINUED FROM PREVIOUS PAGE 1248 1249 .o mm 47.6 mm 9' 228.6 mm 2-5/8'-„j� 15 86.7 mm 62.7 1 3-3/16'„I tsi.v mm 81.0 mm 4-1/2' Model No. Item Offset Finish Non -Lift Off No. Non -Spring No. 11248000004 Hinge Flush (0.0 mm) Polished Chrome 11248000006 11248000002 11248000016 Hinge 1-1/8" (28.6 mm) Polished Chrome n/o n/o 11248000020 Hinge 1-1/4" (31.8 mm) Polished Chrome n/o 11248000019 11248000022 Hinge 1-1/2' (38.1 mm) Polished Chrome n/o n/o 11248000024 Hinge 1-3/8" (34.9 mm) Polished Chrome n/a 11248000018 11248000025 Hinge 1-5/8' (41.3 mm) Polished Chrome n/a n/o 11248000026 Hinge 1-3/4' (44.5 mm) Polished Chrome n/a n/o 11248000027 Hinge 1-7/8" (47.6 mm) Polished Chrome n/o 11248000055 11248000028 Hinge Flush (0.0 mm) Brushed Chrome 11248000007 11248000029 11248000030 Hinge 2" (50.8 mm) Polished Chrome n/o 14 248000080 11248000040 Hinge 1-1/8" (28.6 mm) Brushed Chrome n/c n/o 11248000044 Hinge 1-1/4' (31.8 mm) Brushed Chrome n/o n/o 11248000045 Hinge 1-1/2"(38.1 mm) Brushed Chrome n/o 11248000053 11248000048 Hinge 1-3/8" (34.9 mm) Brushed Chrome n/o 11248000039 11248000049 Hinge 1-5/8" (41.3 mm) Brushed Chrome n/o 11248000037 11248000050 Hinge 1-3/4" (44.5 mm) Brushed Chrome n/o 11248000054 11248000051 Hinge 1-7/8' (47.6 mm) Brushed Chrome n/o n/a 11248000078 Hinge 2" (50.8 mm) Brushed Chrome n/o n/o 11249000002 Hinge R.H. Flush (0.0 mm) Polished Chrome 11249000003 Hinge L.H. Flush (0.0 mm) Polished Chrome 11249000004 Hinge R.H. Flush (0.0 mm) Polished Chrome 11249000014 11249000024 11249000005 Hinge L.H. Flush (0.0 mm) Polished Chrome 11249000018 11249000025 11249000008 Hinge R.H. 1-1/8" (28.6 mm) Polished Chrome 7 11249000014 Hinge R.H. Flush (0.0 mm) Polished Chrome +!� 11249000015 Hinge L.H. Flush (0.0 mm) Polished Chrome 11249000016 Hinge R.H. Flush (0.0 mm) Brushed Chrome JAN 13 2i %J 11249000017 Hinge L.H. Flush (0.0 mm) Brushed Chrome 4 i GD o �J# N1j� PAGE B44 WALK-IN © 2017 Kason Industries, Inc. KAMAN a rn C Z Z O O o� ? Ln U) m m (C) ' m o m m O `> z P9 o. O O Pp o m o � No 9 o S M cn g = z < o� y O DCO in 'cN DN cl m o �I v irn u UU `: m s JAN 13 2020 0 ,q gWOFERM NWMegT : k'� � ' 190 1A MOTION SENSOR i-Sl8 Iel,ll �-Ire I+—tlo�,el--si FEATURES AND ♦ Specifically engineered for installation in Walk-in coolers and freezers. ♦ Uses electronic components to allow for reliable operation in extreme temperatures. ♦ Features a gasketed water -tight enclosure which prevents moisture and dust from entering the sensor and affecting occupancy detection. ♦ Operation: Passive infrared sensor detects motion and turns lights on at temperatures below freezing. Uses DIP switches to set time delay and PIR sensitivity. ♦ Low Bay Sensor: High density optic tens set covers a 20 ft. (7.3 m) diameter with ceiling height up to 20 ft. (6.1 m). ♦ High Bay Sensor: Same as the low bay sensor except with ceiling height from 20 ft. (6.1 m) to 40 ft. (12.2 m). 32 31 12' INSULATED JACKET ON LEADS ♦ Material: Polyr-arbonate ♦ Voltage: 120-277 VAC at 50/60 hz. ♦ Load: 120 VAC with 0-800 W ballast; 277 VAC with 0-1200 W ballast. ♦ Time Delay: Convenient DIP switch adjusts from 10 seconds to 20 minutes after Walk-in is exited. ♦ Temperature Ratings: -20'F (-28.9"C) minimum; 1607 (60°C) maximum. ♦ Electrical Connection: 1/2 NPT thread, 13-1/2" (342.9 mm) AWG wire. ♦ Mounting: Horizontal or vertical foruse with all Kasonifight . fixtures. (Mounting Kit included) ♦ Safety Standards: IP65, UL-listed US and Canada for wet locations and NSF. Model No. Description 11901A00005 Low Bay Sensor With 1901-9 Mounting Kit - 11901A00007 High Bay Sensor with 1901-9 Mounting Kit Above Packaging: 10 per Carton, approx. 7.51b. (3.4 kg) ACCESSORIES 11810LX4000 ...................4' LIGHT FIXTURE, LED 1181 OL21248LB................4' LIGHT FIXTURE, LED 11808000000 ............ :....... LED FIXTURE - -. 11806LED000 ....................LED FIXTURE 91901000009.........I.......... REPLACEMENT WALLMOUNT KIT ; C{ �-n,<s »rrt APPROVALS:-�,Fi—�:., 6Y KA UM1INIUSTRIEs C UL us �;! i,I,•.' -ice_'.! COMPONENT E5 LISTED A UL#t: E101196 — `` DATE: J`#\, J �.._ Mason - Inau5mes InC V ZU I4 All Kgnts KeServetl C 1YC;: IL 8-14-2019 - CITY COPY Set CITY OF EDMONDS BUILDING DEPARTMENT WORK M6Pfl-- Ctidjyk I t OgL,� ADDRESS C C?_ `...�: OWNER L�}-T.� APPROVED DA'1 L- :~ Abbazo BLDG. OFFICIAL:� PERr'! IT NUMBER J3 L'C>Z01 AU WORK Su�ECT To FIELD ,,1,1�1� FOR 7Ct`+ 1� 20IJ EVEL SERVICES CTR. DMONDS E € & IOTCHEN EQUIPMENT ROOF PLAN 11 A� Leftcraft � I ly ,-:lV�I��v�DESIG INC.NC. ;. 519 Main Street ,t Edmonds, Washington 98020 _ Heatcraft Refrigeration Products LLC ' ' 2175 West Park Place Boulevard Stone Mountain, Georgia 30087 770.465.5600 • Fax 770.465.5990 Energy Analysis Form To calculate the approximate energy requirement for a refrigeration system, use the following as a guide: (Condensing Unit Model Number: M Z-009M63CF Compressor: 23310 (Watts X Hours Runtime) _ 1295 Watts at design SST 25 and condensing temperature . 120 18 ]Hours Runtime (Default: 18 hrs. for electric defrost; 16 hrs, for air defrost) Condenser an Motors: If motor efficiency is not known, use [[(Amps X Volts) X 0.75] X Hours Runtime]. 1 Amps 230 Volts 18 Hours Runtime (Default: 18 hrs. for electric defrost; 16 hrs. for air defrost) If motor efficiency is known, use (Watts X Hours Runtime). W atts Hours Runtime (Default: 18 hrs. for electric defrost; 16 hrs. for air defrost) ,Evaporator Model Number: LCA690AEQRC6B Evaporator Fan Motors: If motor efficiency is not known, use [[(Amps X Volts) X 0.751 X Hours Runtime]. 1-8 Amps 230 Volts 22 Hours Runtime (Default: 22 hrs. for electric defrost; 24 hrs. for air defrost) If motor efficiency is known, use (Watts X Hours Runtime). llW atts Hours Runtime (Default: 22 hrs. for electric defrost; 24 hrs. for air defrost) b ent-ric befrost Heaters (if applicable): 0 Watts X Hours Runtime) Watts Hours Runtime (Default: 2 hrs.) Analysis prepared by: Total Watts Per Day 1 33246 DEC 17 2019 DEVELOPMENT SERVICkS. CTR. CITY OF EDMONDS MOZ009M63CF - SUBMITTAL HEATCRAFT` WnridwIdc Rdng—tinn Standard Features Project Name: 019-4049 Project Location: US Quote ID: R520053 Item #: 1010 Submitted For: Leo Submitted On: 0811512019 Submitted By: Chris Parker Submitted From: Identity N: Tag: System Desaiption: Spit system System Tag: • ALL UNITS ARE COMPLETELY LEAK TESTED IN A HELIUM ENVIRONMENT, BUMP TESTED AND ALLOWED TO CYCLE OFF ON THE HIGH AND LOW PRESSURE CONTROL. • EACH UNIT HAS A COPY OF THE RUN DATA SHIPPED INSIDE THE ELECTRICAL PANEL • ELECTRICAL CIRCUITS ARE COMPLETELY CHECKED FOR CONTINUITY • ENCAPSULATED, AUTO -RESET, HIGH AND LOW PRESSURE CONTROLS TO ELIMINATE LEAKS (STANDARD ON ALL HIGH AND MEDIUM TEMPERATURE MODELS, ADJUSTABLE LOW PRESSURE CONTROL STANDARD ON LOW TEMPERATURE MODELS) • PIPING IS LAID OUT TO MINIMIZE STRESS AND VIBRATION AND IS PRE -BENT TO ELIMINATE LEAKS COMPONENT • LARGE ELECTRICAL PANEL FOR EASE OF ACCESS • PREFABRICATED WIRING HARNESSES FOR TIGHT CRIMP CONNECTIONS AND CONSISTENT LABELING • RECEIVER WITH FUSIBLE PLUG, LIQUID SHUTOFF VALVE AND CHARGING PORT IS STANDARD • SIGHT GLASS IS EASILY VIEWABLE • UNIT STAYS ON IF THE HOOD IS REMOVED FOR SERVICING CABINET AND CONSTRUCTION • COMPRESSOR: 1/2 TO 1 HP COMPRESSORS ARE RIGID MOUNTED AND HAVE A • HEAVY DUTY STEEL RAISED BASE WITH 1-1/2' LEGS DISCHARGE LOOP • PAINTED STEEL CABINETS FOR SUPERIOR STRENGTH AND CORROSION • COMPRESSOR: DISCHARGE SERVICE VALVES COME STANDARD ON ALL UNITS PROTECTION • FAN: SPECIFICALLY MATCHED WITH MOTOR AND COIL TO ATTAIN MAXIMUM AIR MOVEMENT AND COOLING vv • DEFROST TYPE - AIR DEFROST • DEFROST TIMER OPTIONS - NO TIMER • BRAND LABEL OPTION - OEM • CRANKCASE HEATER OPTIONS - CRANKCASE HEATER • DISCHARGE LINE OPTIONS - HEAD PRESSURE VALVE • SUCTION LINE OPTIONS - SUCTION TUBE ONLY • BASE OPTIONS -STANDARD BASE • CABINET OPTIONS -PAINTED-OUTDOOR • COIL SELECTION -ALUMINUM FIN COIL LIQUID LINE OPTIONS -LIQUID STANDARD Wails or Obstructions for Multiple Units with Horizontal Air Flow Horizontal Air Flow AIR FLOW AIR FLOW AIR W* *W W* FLOW MIN. unit width E!:� MIN. W* MIN. W* MIN. A •^'.%. y � ^� � •_A•,, ^ `ram IECIEoVEn DEC 17 2019 uEVELUPrWENTSERVICkS CTR. C17Y OF EDMONDS Page 6 of 12 MOZ009M63CF - SUBMITTAL T�F'U w/QeRCIn9eratioI iiiiii PrDjed Name: 019-4049 Prated Location: us Quote ID: R520053 item lt: 1010 Submitted For. Leo Submitted On: 0811512019 Submitted By: Chris Parker Submitted From: IdentityA: Tag: System Desorption: Spilt system System Tag: ❑ For Record ❑ For Approval By: General Product • • Product Family.• MOZ Compressor Brand- Copeland Applrcatlon: Outdoor Compressor Type: Scroll Temperature Rang&: Medum Temp Compressor Hp: 0.9 Voltage: (Volts/P7VHz) 200-23013,VO Compressor Model: ZB08KAE-TF5 Refrigerant Type: R404A Number of Compressor(s). 1 Piping: Standard Cal Type.. Mkradlannel NOTE: THIS EQUIPMENT IS PROHIBITED FROM USE IN CALIFORNIA WITHANY REFRIGERANTS ON THE 'LIST OF PROHIBITED SUBSTANCES- FOR THAT SPECIFIC END -USE, INACCORDANCE WnHCALFORNIA CODE OF REGULATIONS. TITLE 17. SECTION 85974. THIS DISCLOSURE STATEMENT HAS BEEN REVIEWED AND APPROVED BY HEATCRAFT REFRIGERATION PRODUCTS L.0 AND HEATCRAFT REFRIGERATION PRODUCTS LLC ATTESTS. UAMR PENALTY OF PERJURY, THAT THESE STATEMENTS ARE TRUE AND ACCURATE. Ambient Temperature (IF) Saturated Suction Temperature ff) Capacity (BTU/H) Altitude (ft) I AWEF Value 95 22.62 9342.0 0 8.02 NOTE: A WEF 8.021NDICATES REFRIGERATION SYSTEM IS DESIGNED AND CERTIFIED FOR USE IN WALK-IN COOLER APPLICATIONS ABOVE.W F ROOM TEMPERATURE. -. ....-�2`. Corrtpessor(S) Fan Maar(s) Efet M RA&W RLA LRA Quantity Hp FLA Defrost High or Number of MCA MOPD Evap.Fan Defrost Type Low Amps? Conlactors Amps Heater Amps 4.7 37.8 2 1115 1 AIR DEFROST NA 1 15 1 15 Connections (In.) Receiver 90% Full (tu) Fan Blada(s) earner Sound Daia AWvx. Net Weightard Liquid Line Suction Stand 112 7/8 14.0 14 71 198 AGENCY LISTINGS c UL us - 28 7116 4 7/16 LIOUID-3 1/16 AIR FLOW SUCTION 19 3/4 �_ 3 13/I6 2 5/8 2 9/16 -T L - I 1----21 118 CL 5 1/4 1 518 F� Ir 38 1/8 CL 4 7/8 4 7/I6 39 118 211116 UOM inches 4 7/16 DEC 17 2013 OEVELOpMENT SERVICES CTR ,fTY OF EDMONDS Page 5 of 12 Heatcraft Refrigeration Products LLC 2175 west Park Place Boulevard Stone Mountain, Georgia 30087 770.465.5600 • Fax 770.465.5990 Energy Analysis Form To calculate the approximate energy requirement for a refrigeration system, use the following as a guide: Condensing t)nit Model Number: M0H008X62CFM Compressor: 19260 Wafts X Hours Runtime) 1070 jWatts at design SST ,, 25 ,! and condensing temperature 220 18 lHours Runtime (Default: 18 hrs. for electric defrost; 16 hrs. for air defrost) `Condenser Fan Motors: If motor efficiency is not known, use [[(Amps X Volts) X 0.75] X Hours Runtime]. 0.5 Amps 230 Volts 18 Hours Runtime (Default: 18 hrs. for electric defrost; 16 hrs. for air defrost) If motor efficiency is known, use (Watts X Hours Runtime). Watts Hours Runtime (Default: 18 hrs. for electric defrost; 16 hrs. for air defrost) ;Evaporator Model Number: LTA079SA 'Evaporator Fan Motors: If motor efficiency is not known, use [[(Amps X Volts) X 0.751 X Hours Runtime]. 3 Amps 230 Volts 22 Hours Runtime (Default: 22 hrs. for electric defrost; 24 hrs. for air defrost) If motor efficiency is known, use (Watts X Hours Runtime). Watts Hours Runtime (Default: 22 hrs. for electric defrost; 24 hrs. for air defrost) ;Electric Defrost Heaters (If applicable): 0 Watts X Hours Runtime) Watts Hours Runtime (Default: 2 hrs.) Total Watts Per Day 32197.5 Analysis prepared by. r��f�fl9�n DEC 17 20113 C TY OF EDMONDS CT� MOH008X62CFM - SUBMITTAL HEATCRAff Norldwide Retdge�alinn Standard Features Project Name: Q 19-4049 Project Location: US Quote ID. R520053 Item #. 2010 Submitted For. Leo Submitted on. 0811512019 Submitted By: Chris Parker Submitted From: Identity #: Tag: System Description: Spht system System Tag: • ALL UNITS ARE COMPLETELY LEAK TESTED IN A HELIUM ENVIRONMENT, BUMP TESTED AND ALLOWED TO CYCLE OFF ON THE HIGH AND LOW PRESSURE CONTROL. • EACH UNIT HAS A COPY OF THE RUN DATA SHIPPED INSIDE THE ELECTRICAL PANEL • ELECTRICAL CIRCUITS ARE COMPLETELY CHECKED FOR CONTINUITY • ENCAPSULATED, AUTO -RESET, HIGH AND LOW PRESSURE CONTROLS TO ELIMINATE LEAKS (STANDARD ON ALL HIGH AND MEDIUM TEMPERATURE MODELS, ADJUSTABLE LOW PRESSURE CONTROL STANDARD ON LOW TEMPERATURE MODELS) • PIPING IS LAID OUT TO MINIMIZE STRESS AND VIBRATION AND IS PRE -BENT TO ELIMINATE LEAKS • 1* • LARGE ELECTRICAL PANEL FOR EASE OF ACCESS • PREFABRICATED WIRING HARNESSES FOR TIGHT CRIMP CONNECTIONS AND CONSISTENT LABELING • RECEIVER WITH FUSIBLE PLUG, LIQUID SHUTOFF VALVE AND CHARGING PORT IS STANDARD • SIGHT GLASS IS EASILY VIEWABLE • SUCTION SERVICE VALVES FOR HERMETIC COMPRESSORS LOCATED OUTSIDE THE CABINET FOR QUICK INSTALLATIONS. • UNIT STAYS ON IF THE HOOD IS REMOVED FOR SERVICING CABINET AND CONSTRUCTION • COMPRESSOR: IM TO 1 HP COMPRESSORS ARE RIGID MOUNTED AND HAVE A • HEAVY DUTY STEEL RAISED BASE WITH 1-1j2' LEGS DISCHARGE LOOP PAINTED STEEL CABINETS FOR SUPERIOR STRENGTH AND CORROSION • COMPRESSOR: DISCHARGE SERVICE VALVES COME STANDARD ON ALL UNITS PROTECTION • FAN: SPECIFICALLY MATCHED WITH MOTOR AND COIL TO ATTAIN MAXIMUM AIR MOVEMENT AND COOLING • DEFROST TYPE - AIR DEFROST • DEFROST TIMER OPTIONS - NO TIMER • BRAND LABEL OPTION -OEM CRANKCASE HEATER OPTIONS- CRANKCASE HEATER • DISCHARGE LINE OPTIONS - HEAD PRESSURE VALVE SUCTION LINE OPTKAJS - SUCTION TUBE ONLY • CABINET OPTIONS - PAINTED -OUTDOOR COIL SELECTION -ALUMINUM FIN COIL • LIQUID LINE OPTIONS - LIQUID STANDARD Walls or obstructions for Multiple Units with Horizontal Air Flow Horizontal Air Flow AIR FLOW AIR FLOW AIR W* *W - W* FLOW MIN. unit width E MIN. I W* +`MIN. W* MIN. DEC 17 2013 DEVELOPMENT SERVICE CTN. CITY OF EDMONDS Page 10 of 12 MOH008X62CFM - SUBMITTAL HEAWRAFT Nbrldwiac Ralrlgeratbn ❑ For Record ❑ For Approval Project Name: 0194049 Project Location: US Ouote ID: R520053 item N: 2010 Submitted For: Leo Submitted On: 0811512019 Submitted By: Chris Parker Submitted From: Identity #: Tag: System Description: Spilt system System Tog General Product • • Product Family: MOH Compressor Brand.- Copeland Application: Outdoor Compressor Type: Hermetic Temperature Range: Extended Temp Compressor hp.- 0.75 Voltage: (VoltSIPh/Hz) 208.230/1/60 Compressor Model: RST55ClECAV Refrigerant Type: R404A Number of Compmssor(s): 1 Piping- Standard Cdl Type: Mauchannel NOTE: THIS EQUIPMENT IS PROHIBITED FROM USE IN CALIFORNIA WITHANY REFRIGERANTS ON THE *UST OF PROHIBITED SUBSTANCES' FOR THAT SPECIFIC END -USE, IN ACCORDANCE WITH CALIFORNIA CODE OF REGULATIONS, TIRE 17, SECTION 95374, THIS DISCLOSURE STATEMENT HAS BEEN REVIEWED ANDAPPROVED BY HEATCRAFT REFRIGERATIONPRODUCTS UCANO HEATCRAFT REFRIGERATION PRODUCTS UCATTESTS. UNDER PENALTY OF PERJURY, THAT THESE STATEMENTS ARE TRUE ANDACCURATE. Ambient Temperature (7) Saturated Suction Temperature (IF) Capacity (BTU11-0 Altitude (lt) AWEF Value 95 24.18 69"..0 0 7.83 NOTE:AWEF 7.83 INDICATES REFRIGERATION SYSTEM IS DESIGNED AND CERTIFIEDFORUSEIN WALK-IN COOLER APPLICATIONS ABOVE rVFROOM TEMPERATURE. (:orripr•16sor{8 Fan MOfoT(s) EAsam Ratings RLA LRA Quantity Hp FLA Defrost High or Number of MCA MOPD Evap.Fan Defrost Type Low Amps? Contactors Amps Heater Amps 6.1 33.7 1 1/15 0.5 AIR DEFROST NA 15 15 Connections (in.) Receiver 90% Full (Ibs) FanD e() Sound Data We/x' Not Liquid Line Suction Standard ��4 (in)(M) 3/8 1R 5.5 14 68 135 28 1/2 �— LIOUID AIRaOW SUCTION 2 7/16 17118 2 3/8 ff I L F-� 21 1/8 CL F-- 22. 118 CL 1 9/16 25 1/8 -- 4 3/8 UOM Inchon AGENCY LISTING'S C VL us 2 3/4 —3 T 211 I/16 — 4 7/8 EMMM® DEC 17 20113 JEVELOPMEWT SERVICES C-M. CITY OF EDMONDS Page 9 of 12 LCA690AEQRC6B - SUBMITTAL LARKIN Project Name: 019-4049 Project Location: us Quote ID: R520053 Item #: 1020 Submitted For: Leo SubrndW On: 0811512019 Submitted By: Chris Parker SubnittedFrom: Identity A Tag: System De ,tion: spit system System Tag: Standard Features EASE OF INSTALLATION & SERVICE PERFORMANCE • ALL ELECTRICAL COMPONENTS FACTORY WIRED TO TERMINAL BOARD AND INTERNAL PANELS ARE ISOLATED FOR QUIET OPERATION IDENTIFIED, MAKING IT EASY TO FIELD WIRE THE UNIT • INTERNALLY ENHANCED TUBING AND FIN DESIGN FOR HIGHER EFFICIENCY • CABINET DESIGN FEATURES FRONT ACCESS PANELS ON EACH SIDE FOR EASY ACCESS TO ELECTRICAL AND REFRIGERATION COMPONENTS • LIQUID LINE SOLENOID WIRE HARNESS IS FACTORY -INSTALLED FOR QUICK INSTALLATION • MOTORS PLUG INTO WIRING HARNESS FOR EASIER SERVICING • ON 4-6 FAN MODELS. DRAIN PAN HAS A LANYARD FOR EASY AND SAFE ACCESS • PRE -DRILLED HOLES ON THE BACK OF THE UNIT FOR ROOM THERMOSTAT - RELIABLE & DURABLE VERSATILE • ATTRACTIVE WHITE CABINET LARGE DIAMETER DRAIN HOLE (3/4- ID) IS LOCATED ON THE BACK OF THE UNIT • MOLDED FAN GUARD DESIGN MADE OF STRONG PLASTIC MATERIAL • MINIMAL HEIGHT OF THE LOW PROFILE SERIES MAKES IT IDEAL FOR LOW • SWEAT CONNECTIONS TO REDUCE POTENTIAL FOR LEAKS CEILING COOLERS • Variant condition - null • COIL SELECTION - ALM FIN COIL - BEACON • COIL COATING -ALUMINUM - • COIL MECHANICAL OPTION -BEACON • CONTROL OPTIONS - QRC CONTROLLER CONTROLS - ORC • VOLTAGE ASSEMBLY SELECTION - 115V EC FAN BLADE SELECTION - STANDARD FAN BLADE • CARTON OPTIONS -STANDARD CARTON FAN GUARD SELECTION - LARKIN PLASTIC GUARD • NOZZLE SELECTIONS -NOZZLE INSTALLED PLAN VIEW 11/2 H N AIR FLOW PLAN VIEW l •-N - One Evaporator f t 11/2 H 11/2 H + + NOTE: -► 11/2H 3H 11/2H H =Total Height evaporator coil surface. Two Evaporators N'i140114 IVf [i� DEC 17 2013 AVEf_ HVILIlyf SERVICES-CTR. CITY OF EDMONDS Page 8 of 12 LCA690AEQRC6B - SUBMITTAL Project Name: 019-4049 PmJect Location: us Quote ID: R520053 Item #: 1020 Submitted For., Leo Submitted On: 0611512019 Submitted By. Chris Parker Submitted From: Identity #: Tag: System Description : Spry system System leg: ❑ For Reoord ❑ For Approval By: _ Date: Product Family: LCA6 Motor type EC Defrost Type: Air Number of Fans: 2 Voltage: (VOHS)PNHI) 115/l/60 Fan HorsePowor 1/15 Refrigerant Type: R404A Fins per Inch 6 Capacity Air Flow AWEF Value TD (°F) SST (°F) Capacity (BTUM) CFM Fan Diameter (K) Air Throw (1t)� Standard w/CoAar 10.38 22.62 9,000 1,400 12 N/A Fan Motor(s) Delmar hleater(s) Drain Pan Heaters) Watts Amps watts Amps watts Amps 114 1.8 Connections; (in.) AW-.. Net Weight (Ibs) Coll Intel Su06017 External Equalzef Drain Side Pat Hot Gas Drain Pan 1/2 718 114 V4 48 Jr�rr. rMyi u/-ir Jz�vrR�,f t) T/s•' Eroccriea� KnockO�ta AGENCY LrST#IPGS r a S. NSF 2 1/S 2 1/4 ....I l- 1 3/4 t.._ 4 3/16 Refrigerant Electrical Connection End Connection End 13 1/4 I 6 1/S --• 11 Fes— 33 1/4--f F— 6 I/S 7- 14 3/4 1- AIR FLOW 2 i /S 16 3/4MPT 114 NPSI 12 uoF* inch.. 45 5/16 Drain Connection 14 13116 S1 IS��WU�® DEC 17 2019 ')EVEWPndtN'1' SERVICES-C71i. C17Y OF EDMONDS Page 7 of 12 LTA079SA - SUBMITTAL Project Name: 019-4049 Project Location: us Quote ID: R520053 ttem #: 2020 Submitted For: Leo Submitted On: 0811512019 Submitted By: Chris Parker SubnittedFmm: Identity #: Tag: System Descrlptian. Spit system System Tag: Standard Features CABINET AND CONSTRUCTION COILS • EASY ACCESS TO MOTORS AND THE REFRIGERANT AND ELECTRICAL BLOW -THROUGH COIL MEANS AIR IS DISCHARGED THROUGH THE COIL COMPONENTS WITH FRONT ACCESS PANELS • HEATERS ARE ATTACHED TO THE COIL FOR EASIER SERVICEABILITY • LIQUID -LINE SOLENOID WIRE HARNESS COMES STANDARD FOR QUICK • INTERNALLY ENHANCED TUBE DESIGN PRODUCES BETTER UNIT PERFORMANCE INSTALLATION • LOW HEIGHT MAKES IT THE MOST COMPACT UNIT FOR DISPLAY CASES WHERE SPACE IS LIMITED, GIVING THE CASE A CLEAN LOOK AND ALLOWING FOR MORE SHELVING AND PRODUCT STORAGE • MODULAR FRONT ACCESS PANELS CAN BE REMOVED INDEPENDENTLY OF THE DRAIN PAN • PLASTIC VIBRATION ISOLATORS FOR FAN PANELS AND DRAIN PAN REDUCE NOISE AND VIBRATION • TEXTURED ALUMINUM CABINET CONTROLS • DEFROST TERMINATION CONTROL • FAN DELAY CONTROL • HEATER SAFETY CONTROL • COIL COATING -ALUMINUM • COIL MECHANICAL OPTION -NONE • CONTROLS -NONE MOTOR TYPE - EC • COIL SELECTION - ALUM WISHRADER NOZZLE SELECTIONS - R22 NOZZLE KIT + NOZZLE SELECTIONS - R404A NOZZLE KIT • VOLTAGE ASSEMBLY SELECTION -115V EC • NAMEBRAND SELECTION - LARKIN • FAN BLADE SELECTION - STANDARD FAN BLADE • CABINET OPTIONS - STUCCO CABINET D•sWptlon Qoall" • QRC CONTROLS Coils 7.5" 3" 3" One Evaporator 7.5" Coils 7.5" Coils 3" 6" 3" Two Evaporators DEC 17 205l uEVEtA ZY Of EDMONDS CTI Page 12 of 12 LTA079SA - SUBMITTAL ❑ For Record Project Name., 019-4049 Project Location: us Quote ID. R520053 /tern A, 2020 Submitted For: Leo Submitted On: 0811512019 Submitted By. Chris Parker Submitted Fmm: identify A: 11 1 Tag: System DesmpPfai,: I Split system I System Tag: ❑ For Approval By:_ Date: Product Family: LTA Motor type EC Defrost Type: Air Number of Fans: 3 Voltage:(Voffs1PtVHz) 11511/60 Fan HorsePower 1/15 Refrigerant Type: R404A Fins per Inch 7 Capodly Air ROW 4F) SST Capacity CFM Fan Diameter Air Throw (R) �� AWEF Vsfue (F) (BTU/H) (it) Standard w,Collar 24. 18 7,900 1,350 10 N/A Fan Motors) DOW Hemter(s) Drain Parr Heater(S) Watts Amps Watts Amps watts Amps 90 3 (LJctiI.;Y)�+t l•^.i;}qjs ^tip Connediorrs (in.) Apor- Net Weight Coll In!et Suction External Equalizer Drain Side Pat Hot Gas Drain Pon (tom) 1/2 5R 114 314 69 _CJMviar.�i':�ld li 'iaf5Yri1?A(�x) AGENCY LSTINGS 7/8" ELECTRICAL DRAIN FITTING TS 3 5ns — 2 1/4 V 8718 ®coos NSF. 1 1/2 I 7/8 :'^ L 3/4-14 NIPSe 2 9/16 REAR VIEW 1 3/8 2 9/l6 DRAIN CONNECTION FRONT VIEW 69 1/8 —•-I 18 5/16 ELECTRICAL CONNECTION REFRIGERANT CONNECTION 8 718 199116 END END 6.5/8 10 1/16 i 314 I I AIR FLOW 215/I6 f-605/8-i159/16 18 1/8 UOM inches TOP VIEW SIDE VIEW RECE IVEC�� DEC 17 2013 DEVELOPMENT SERVICES CTF1. CITY OF EDMONDS Page 11 of 12 724 16 35M- - 694 - -- 16 3216 C1 - 1 20-- 12. 1 - }�°•X-fi{2 CONT: 26GA: 24 3 8' X 8" LAG SCREW GALVALUM TOP CAP AND WASHER D23" O.C. WITH #8 X 3/4" TEK /-26GA. METAL SCREWS 0 23" O.C. —CEILING PANEL CAULKING 3/8" BEAD MIN. NSF GASKET- --CAULKING 3/8" BEAD MIN. (FREEZER ONLY) WALL PANEL J -FOAM CEILING TO WALL WOOD UL-C K-78 K-1248 KK 1094 OUT -SWING LEFT ELEVATION SPECIFICATIONS 12316" 12316" ----- CONSTRUCTION: 724 351�' WALL: 5" WOOD -FRAME, POLYURETHANE, F-I-P �R-3 16 CEILING: 5" WOOD -FRAME, POLYURETHANE F I P )] - o FINISH: - WALL: 22GA. SST INTERIOR WHERE INDICATED C1 IMlfr C2 26GA. STUCCO -WHITE BALANCE OF INTERIOR 22GA. SST EXTERIOR WHERE INDICATED t/8" PLYWOOD EXTERIOR WHERE INDICATED 6 TOP VIEW (CEILING AI..I.. '"`0P;< ^LI RU CT CEILING: 26GA. STUCCO-GALVALUM BALANCE EXTERIOR 26GA. STUCCO -WHITE INTERIOR ss= F'.ELD 26GA. STUCCO-GALVALUM EXTERIOR 20'-8" [248] O.D. IP> SPE, T iON FOR ACCESSORIES: KEG COOLER GODS COMPLIANCE 1 EA. - 30" X 80" HINGED COOLER DOOR 6'-04" [724] 13'-34" [159NG 4] 16 22GA. SSTSELF-CLOJAMB (MAGNETIC) 22GA: SST INT & EXT (DOOR & DOOR SECTION) 1121 1157 I6 47' W4 W5, 8 W7 1 47 47 47" 12 W9 W5 W5 1 1 EA. - 36"H .100" DT/ALUM KICKPLATE INT & EXT. 24" X 80" HINGED COOLER DOOR SELF -CLOSING --------- -- .-.-- _.- -_. _---_ _ • -- - - -----_ . _=_. 22GA. SST JAMB (MAGNETIC) 22GA. SST INT & EXT (DOOR & DOOR SECTION) ' ] C A �IW6 " �W6 26GA. STUCCO -WHITE i ©' W11 2 EA. - 36"H .100" DT/ALUM KICKPLATE INT & EXT KASON LED LIGHT FIXTURE #1808 EA _ _ 2 EA. - 2 EA. - LIGHT SWITCH W/ DIGITAL TM (1 - SHIP LOOSE) KASON MOTION SENSOR #1901A - -- __-� 1 EA. - 30" X 80" 6" STRIPS PLASTIC CURTAIN i 1 EA. - 24" X 80" (6" STRIPS; PLASTIC CURTAIN r 30 NOTES: 23_ 47___ 47--47"_ 9 2516 41 1 I LAG DOWN CEILING THE CEILING IS DESIGNED FOf�' W3 W2 W2 W2 Wi DS1 �ORAO��® ilfP1, RD PLAF-HO MUST BI PLAN VIEW 3" 8 PLYWOOD WOOD UL-C K-78 • K-1248 K-1094 �N o-- w W z JAMB � wn- F !� RESUB I' qEC -9 2019 TYPE COUNT JAN 2 3 2020 H TOTAL - ®� S TOTAL - BUICDING pEPAR'fM5 DSTOTAL 2 (CIW TOTAL 15 7/ C TOTAL 2 __ `, F TOTAL geev-1.:001'ev- y GRAND TOTAL: 1 12/0/19 BOX DIMENSION MARIO IQ it/11/19 CHANGED BOX DIMENSION & (1) DOOR SIZE pHAT CHANGED BOX EXTERIOR FINISH REV. WTE DESCRIPTION REV. E1' f Custom Cooler 420 E. ARROW HIGHWAY 1005 SIGMAN ROAD NE SAN DIMAS, CA 91773 CONYERS. GA 30013 TEL: 909 592.1111 TEL: (678) 7125656 FAX: 909 599.6225 FRONT ELEVATION LEFTCRAFT CUSTOMER CRAFT RESTAURANT SUPPLY 519 MAIN STREET DRnwNer MARIO-WINGW.: DAT CUSTOM COOLER PRODUCTS COMPLY WITH THE "R' VALUE REQUIREMENTS OF SECTION 340 OF THE ENERGY POLICY EDMONDS, WA 98020 12/03/19 19-1985-1 AND CONSERVATION ACT (42 U.S.C. 6311) AND CALIFORNIA TITLE 20 AND TITLE 24.E INDOOR KEG COOLER ° 1/4."-1'—O" SHEET OF OUT -SWING B SPECIFICATIONS 20'-8" [248] O.D. KEG COOLER 6'-04" [724] 1. 4,r 13'-34" [1594] <1 C>' _ o A 26GA. STUCCO -WHITE ' -- I I � OUT -SWING LEFT ELEVATION L 17'-2" PLAN VIEW 22GA. SST l ,,� I 3" PLYWOOD -- � Z U' I I I i� W_ J _ W o in �' OUT -SWING ° FRONT ELEVATION CONSTRUCTION: WALL: 5" WOOD -FRAME, POLYURETHANE, F-I-P R-37 CEILING: 5" WOOD -FRAME, POLYURETHANE, F-I-P R-37 FINISH: WALL: 22GA. SST INTERIOR WHERE INDICATED 26GA STUCCO -WHITE BALANCE OF INTERIOR 22GA. SST EXTERIOR WHERE INDICATED 3/8" PLYWOOD EXTERIOR WHERE INDICATED 26GA. STUCCO-GALVALUM BALANCE EXTERIOR CEILING: 26GA. STUCCO -WHITE INTERIOR 26GA. STUCCO-GALVALUM EXTERIOR ACCESSORIES: 1 EA. - 30" X 80" HINGED COOLER DOOR SELF -CLOSING 22GA. SST JAMB (MAGNETIC) 22GA. SST INT & EXT (DOOR & DOOR SECTION) 36"H .100' DT/ALUM KICKPLATE INT & EXT 1 EA. - 24" X 80" HINGED COOLER DOOR SELF -CLOSING 22GA. SST JAMB (MAGNETIC) 22GA. SST INT & EXT (DOOR & DOOR SECTION) 36"H .100" DT/ALUM KICKPLATE INT & EXT 2 EA. - KASON LED LIGHT FIXTURE #1808 2 EA. - LIGHT SWITCH W/ DIGITAL TM (1 - EA SHIP LOOSE) 2 EA. - KASON MOTION SENSOR #1901A 1 EA. - 30" X 80" (6" STRIPS) PLASTIC CURTAIN 1 EA. - 24" X 80' 6" STRIPS) PLASTIC CURTAIN NOTES: LAG DOWN CEILING THE CEILING IS DESIGNED FOR "NO STORAGE" SECTION 2603.4.1.2 COMPLIANCE DATA COMPOSITE PANEL— SURFACE BURNING CHARACTERISTICS: FLAME SPREAD: 20 - SMOKE DEVELOPED: 250-400 CORE FLASH IGNITION TEMPERATURE: 8967 CORE SELF —IGNITION TEMPERATURE: 9WF V&UEs ARE REPOR7M BY UNDERNRRERS LA90RATDPoE3 FILE W. 2520 AND SYIbJbb - - SPRINKLER SYSTEMS PRE UNDER SEPWE KNIT - B ESU B JAN 2 3 2020 SUICITYYO DMONDSNT 2 12/03/19 CHANGED BOX DIMENSION _ MARIO- SUBMITTAL DRAWING 0 I1/I1/19 CHANGED BOX DIMENSION & (1) DOOR SIZE PH4T CHANGED BOX EXTERIOR FINISH MUST BE SIGNED & RETURNED BY ---------- O^^E DESCRIPTION REV. SY TO BE SHIPPED ON____________ Custom Cooler ❑ NOT APPROVED -REVISE AND RESUBMIT ❑ APPROVED AS NOTED - MANUFACTURE AS NOTED ❑ APPROVED AS IS - MANUFACTURE AS DRAWN 420 E. ARROW HIGHWAY 1005 SIGMAN ROAD HE SAN DIMAS, CA 91773 CONYERS, GA.30013 L�1�M F00LOWE !! PANE, TEL: (908)582-1111 TEL:(678) 712-5656 FAX: (809) 599-6225 aoa cusroNLxe: LEFTCRAFT CMA RESTAURANT SUPPLY D&VIE 9)009 519 MAIN STREET DRAV NBN BAU —INGND.: EDMONDS, WA 98020 wrE 10/30 19 19-1985-1 CUSTOM COOLER PRODUCTS COMPLY WITH THEW VALUE REQUIREMENTS OF SECTION 340 OF THE ENERGY POLICY AND CONSERVATION ACT (42 U.S.C. 6311) AND CALIFORNIA TITLE 20 AND TITLE 24. INDOOR KEG COOLER sCaE: j 4"-1'-0" SHEET -I OF > `> 1" X 6%" CONT. 26GA. 2GALV. <' " 3/8" ' h STEEL TOP CAP 26GA. METAL X 6�" CONT. 26GA. 24" X 8" LAG SCREW GALVALUM TOP CAP AND WASHER 023" O.C. WITH8 X 3/4" TEK SCREWS ® 23" O.C. WITH8 X 3/4" TEK 26GA METAL CEILING PANEL ' SCREWS 0 23" O.C. CAULKING 3/8" BEAD MIN '; CEILING PANEL CAULKING —� _ °� NSF GASKET 3/8" BEAD MIN. T, NSF GASKET SCAM LOCK FASTENER �; CAULKING NSF GASKET 3/8" BEAD MIN. l FOAM `; WALL PANEL f (FREEZER ONLY) WALL PANEL 1 FOAM T l , 1 41 CAM LOCK CEILING TO WALL <; 1 1 CEILING TO WALL EXTERIOR CAULKING 3/8" BEAD MIN. 2X4 26GA. METAL FOAM PLUG BUTTON CAM LOCK FASTENER 0 48"O.C. MAX. INTERIOR SUBMITTAL DRAWING MUST BE SIGNED & RETURNED BY ---------- TO BE SHIPPED ON-----------_ ❑ NOT APPROVED -REVISE AND RESUBMIT rJ NOT USED 2 PANEL TO PANEL (COOLER) ❑APPROVED ASNOTED - MANUFACTURE ASNOTED ❑APPROVED AS IS- MANUFACTURE AS DRAWN EXTERIOR < DM(60MERL3W DDLA14Lga WALL PANEL INTERIOR ( DDG14C @9@a SILICONES TOP & BOTTOM 6" COVE BASE AS REDURED & ACCEPTABLE BY CODE ; 26GA.— 6 H. COVE BASE 1}° X 26GA. METAL SCREED W/�8 X 3/4" TEK SCREW `, RESUB )'3 )j; #14 X 1%' TEK @23" O.C. ))>; SCREWS 0 23" O.C. <' JAN 2 3 2020 FINISH FLOOR ; CAULKING . ULKING ; IQ 11/I I/19 Cry CHANGED DEAL #4 & REVISED DETAIL rya OF EDMONDS CHAT 3/8" BEAD MIN.^ >.:: ,°3/8° BEAD MIN. DESCRIPTION BEV. BV Custom Cooler HILTI KH—EZ 1/4" DIA. • ' < ' ' •' • ' ASSUMED MINIMUM DESIGN: ; 1 5/8' EMB. @ 24° O.C. 4" THK, 2500 PSI CONIC. SLABS ` ' ESR 3027 G.C. TO VERIFY420 IARR 25897 OR EQUAL �� E. SAN DIMAS, CA 9OW 1 TT CONY RSS, IODS GA 30013 OAD E C21111 ` TEL; 4909; TEL: (878) 712 5W6 FAX: 909 599.6225 > NOTE. <' FOR All MECBANICAULY FASTENED ANCHORS,LEFTCRAFT INSPECTION MAY BE REQUIRED. VERIFY J09: CUSTOMER CMA RESTAURANT SUPPLY \SPECIAL WITH LOCAL Bmmmc OFFICIAL 519 MAIN STREET mm- BAU41,97,985-1) EETAILS , wA s8ozo DATE 10/.T.S.OF3DETAILS 6 NOT USED 3 WALL TO CONCRETE FLOOR s� N.T.S.SHEET 3 OF 3 10'-9" [129] O.D. COOLER 17167 47" 47" 177 16 36 W2 W2 W7 ,8 10 - M� W5 t-E —M o v W2 d o ����'k�� Wz 26GA. STUCCO -WHITE . k W4 A 10 0 0 0 Ii -� 36 82 47 _ 47" 2616 W3 DS1 W2 W1 PLAN VIEW ro JAMB � OUT -SWING SPECIFICATIONS CONSTRUCTION: WALL: 5" WOOD -FRAME, POLYURETHANE, F-I-P CEILING: 5" WOOD -FRAME, POLYURETHANE, F-I-P FINISH: 129 WALL: 22GA. SST INTERIOR WHERE INDICATED - ---- 26GA. STUCCO -WHITE BALANCE OF INTERIOR 22GA. SST EXTERIOR WHERE INDICATED 84,184 27 20 27 184 84 CEILING: 26GA. STUCCO-WHITELN)TERIORNCE EXTERIOR 26GA. STUCCO-GALVALUM EXTERIOR ACCESSORIES: N8 N� C) ^N� I EA. - 36" X 74" HINGED COOLER DOOR SELF -CLOSING --- o - 22GA. SST JAMB (MAGNETIC) 22GA. SST INT & EXT (DOOR & DOOR SECTION) 36"H .100" DT/ALUM KICKPLATE INT & EXT N2 101 36f-6 C2 36A 361-5� 0 2 EA. - KASON LED LIGHT FIXTURE #1808 1 EA. - LIGHT SWITCH W/ DIGITAL TM. --- 1 EA. - KASON MOTION SENSOR #1901A k 1 EA. - 36" X 74" (6" STRIPS) PLASTIC CURTAIN N2 C2 NOTES: 0 o CAM LOCK CEILING o _ ff CEILING IS DESIGNED FOR "NO STORAGE" V9s C3 �s 0.I .27_.y2 10-16� 27234�138� II ��� ������ o i ,fits Q �0 " TOP VIEW (CEILING ®LOD ALL WORK SUBJECT _ TO FIELD N0'�'PE F; E'"' INSPECTION FOR DEC -� 2019 22GA. SST CODE COMPLIANCE _ S TOTAL - S TOTAL 1 TOTAL 15 C TOTAL 4 D F OTAL GRAND TOTAL• 20 I 11/n/19 CHANGED BOX DIMENSION & DOOR SIZ CHANGED BOX EXTERIOR FINI LOCK.000NG PST C® aev. on oesaemnou - �v. er Custom Cooler 42D E. ARROW HIGHWAY - 1005 SIGMAN ROAD RES® 91® SAN DIMAS, CA 91773 CONYERS. GA. 30013 E 4�.6 t� TA809)5995 EL: 9097J 592-1TEL: (678) 7125656 X. 225111 FRONT ELEVATION JAN232020 T NE„ EPARTMEN LEFTCRAFT CMA RESTAURANT SUPPLY 8LBLDDINO MONDS 519 MAN STREET. wuwner. MARIO oanwmo na: EDMONDS, WA 98020 nne: 12 03/19 19-1985-2 CUSTOM COOLER PRODUCTS COMPLY WITH THE "R" VALUE REQUIREMENTS OF SECTION 340 OF THE ENERGY POLICY AND CONSERVATIONACT(42U.S.C.6311)AND CALIFORNIA TITLE 20 AND TITLE 24. INDOOR COOLER scnie I/4"=1'-0SHEET 20F3 j 10'-9"v[1291 O.D. COOLER s--------------- c � D u (E) 6"0 COL.— <2C> 1' ;� 26GA, STUCCO=WHITE A 22GA. SST _;-O 22GA. SST 1 '-2 3' 6'-7" , PLAN VIEW t N 1 I SPECIFICATIONS CONSTRUCTION: WALL: 5" WOOD -FRAME, POLYURETHANE, F-I-P R-37 CEILING: 5" WOOD -FRAME, POLYURETHANE, F-1-P (R-37) FINISH^ - - ✓v . -� WALL: 22GA. SST INTERIOR WHERE INDICATED (� 260A. STUCCO -WHITE BALANCE OF INTERIOR 22GA. SST EXTERIOR WHERE INDICATED ' 26GA. STUCCO-GALVALUM BALANCE EXTERIOR 1 p CEILING: 26GA. STUCCO -WHITE INTERIOR 1% `. : 26QA „STt,�CCQ-QALyALt,IM ,EXT,�RIQR ACCESSORIES: _ - - 1 EA. ,-4 W,' 7HINGED COOLER DOOR SELF -CLOSING 220A. SST JAMB (MAGNETIC) 22GA. SST INT & EXT (DOOR & DOOR SECTION) 36"H .100" DT/ALUM KICKPLATE INT & EXT 2 EA. - KASON LED LIGHT FIXTURE #1808 1 EA. - LIGHT SWITCH W/ DIGITAL TM 1 EA. - KASSN MOTION SENSOR #1901A 1 EA.- (` 6" 041(6" STRIPS) PLASTIC CURTAIN fHE CEILING IS DESIGNED FOR "NO gTOPAr,F" SECTION 2603.4.1.2 COMPLIANCE DATA COMPOSITE PANEL- SURFACE BURNING CHARACTERISTICS: FLAME SPREAD: 20 SMOKE DEVELOPED 250 400 CORE FLASH IGNITION TEMPERATURE:,896-F - CORE SELF -IGNITION TEMPERATURE: 914-F VALUE$ ARE REPORTED W UNDERU1- LABORATORIES FILE ND:254S5--- AND SVI ft WRINNIER S FEMS ME UNDER SEPARATE PERMIF RESWB DIN 2 3 20 20 D BUILDING DEPARTMENT CITY OF EDMONDS FRONT ELEVATION SUBMITTAL DRAWING Q „/„/19 CHANGED BOX DIMENSION & DOOR SIZE CHANGED BOX EXTERIOR FINISH / CAN LOCK CEILING PHAT MUST BE SIGNED & RETURNED BY __________ REV. DATE oEEDwPnoN REv.Ev TO BE SHIPPED ON____________ I� - D.NOTAPPROVED -REVISE AND RESUBMIT �CStom CnOier APPROVED AS NOTED - MANUFACTURE AS NOTED ❑ APPROVED AS IS - MANUFACTURE AS DRAWN - 420 E. ARROW HIGHWAY SAN DIMAS, CA 91773 1006SIGMAN ROAD HE . ��ISONILG3S7 DD /,"W Il L5o° TEL (809) 692-1111 FAX: 909 5998225 CONYERS, CA 30013 TEL (878) 712fi658 JOS: LEFTCRAFT 519 MAIN STREET CUSTOMER: CMA RESTAURANT SUPPLY NAVE oR®b DRAVM" BAU e oRAx No : EDMONDS, WA 98020 DATE: 10/30/19 CUSTOM COOLER PRODUCTS COMPLY WITH THE "R" VALUE REQUIREMENTS OF SECTION 34G OF THE ENERGY POLICY - 19-1985-2 AND CONSERVATION ACT(42 U.S.C.6311) AND CALIFORNIA TITLE 20 AND TITLE 24. INDOOR COOLER ED.E: 1/4 "=1'-0" SHEET 2OF3- > 2" X 0 CONT. 26GA. 1 SCREW > GALV. STEEL TOP CAP y" JB' X 8" LAG h" X 6%" CONT.26Gk- 24 AND WASHER 023' O.C. WITH #8 X 3/4" TEK 26GA.. METAL GALVALUM TOP CAP SCREWS ® 23" O.C. WITH #8 X 3/4" TEK -26GA METAL ' CAULKING, CEILING PANEL <, : CEIUNO PANEL SCREWS 0 23" O.C. 1-} 3/8" BEAD MIN. \ CAULKING ; j > NSF GASKET t - 1 NSF GASKET SCAM LOCK FASTENER 3/8" BEAD MIN. CAULKING NSF CASKET 3/8" BEAD MIN. FOAM (FREEZER ONLY) > WALL PANEL-/ ; WALL PANEL --FOAM `> > 1 CEILING TO WALL 4 CAM LOCK CEILING TO WALL <; EXTERIOR CAULKING BEAD MIN. *2X4-,26CA.METAL FOAMPLUG BULCK FASTENER 0 48"0.C. MAX. INTERIOR NOT USED NOT USED SUBMITTAL DRAWING MUST BE SIGNED & RETURNED BY TO BE SHIPPED ON--____---___ ❑ NOT APPROVED -REVISE AND RESUBMIT _ ❑ APPROVED ASNOTED - MANUFACTURE ASNOTED ❑ APPROVED AS IS - MANUFACTURE AS DRAWN 21 PANEL TO PANEL (COOLER) EXTERIOR ` DDGdONICG3�lDDL^�4Co INTERIOR WALL PANEL DD L14C� �OC�3(nl SILICONES TOP & BOTTOM 6" COVE BASE ��su AS REQUIRED & ACCEPTABLE BY CODE 1 " X 26GA. METAL SCREED ` 26GA- 6'H. COVE BASE W/#B X 3/4" TEK SCREW 1'14 X 111h" TEK ` JAN 2 3 2020 023 O.C. SCREWS ® 23" O.C. <� FINISH FLOOR BUILDING DEPARTMENT CITYOFEDMONDS CAULKING _ .. < CAULKING Q II/11/19 CHANCED DETAIL #4 @ REVISED DETAIL #3 PHAT 3/8" BEAD MIN..-.-. < .,. `. 3/8" BEAD MIN. `T REV. DATE DESCRIPTION REV. BY HILTI KH-EZ 1/4" CIA. 1 5/8' EMB. 0 24' O.C. ASSUMED MINIMUM DESIGN: 4' INK. 2500 PSI CONC. SLAB( ` Custoril Cooler. ESR 3027 LARR 25897 OR EQUAL G.C. TO VERIFY 420 E. ARROW HIGHWAY 1005 SIGMAN ROAD NE SAN DIMAS. CA 91773 CONYERS, GA. 3DO13 <T TEL: ((9D9)) 592-1111 TEL (678) 712-5555 FAX: (909) 5996225 FOR ALL MECHANICALLY FASTENED ANCHORS, �' LEFTCRAFT DDErDRER: CMA RESTAURANT SUPPLY SPECML INSPECTION MAY BE REQUIRED. VERIFY ` WITH LOCAL BUILDING OFFICIAL" ^ j _^-_^-.^ .^ _^ _^ _^ _, _^ .^ _^ _. ,. _, _. _^ _^ .^ _. 519 MAIN STREET EDMONDS, WA 98020 DRAwT1 ev: BAO DI ANNCND: 19-1985-D DATEo 10/30/19 - 3 WALL TO CONCRETE FLOOR DETAILS SHEET 3OF3 'D"E' N.T.S.