Loading...
BLD2021-0529_Other_4.13.2021_9.00.56_AM_2142063__I& I RON RI DGE Flush Mount System Built for solar's toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested All components evaluated for superior structural performance. Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof. UL 2703 Listed System ® Entire system and components meet newest effective UL 2703 standard. PE Certified Pre -stamped engineering letters available in most states. - Design Assistant ® Online software makes it simple to create, share, and price projects. 20-Year Warranty Twice the protection offered by competitors. XR Rails O XR10 Rail i A low -profile mounting rail for regions with light snow. • 6' spanning capability • Moderate load capability • Clear and black finish XR100 Rail The ultimate residential solar mounting rail. • 8' spanning capability • Heavy load capability • Clear and black finish Clamps & Grounding O — UFOs Universal Fastening Objects bond modules to rails. • Fully assembled & lubed • Single, universal size • Clear and black finish Attachments 6 — FlashFoot2 Flash and mount XR Rails with superior waterproofing. • Twist -on Cap eases install • Wind -driven rain tested • Mill and black finish Resources Stopper Sleeves _L Snap onto the UFO to turn into a bonded end clamp. • Bonds modules to rails • Sized to match modules • Clear and black finish Slotted L-Feet XR1000 Rail Bonded Splices A heavyweight mounting All rails use internal splices rail for commercial projects. for seamless connections. • 12' spanning capability • Extreme load capability • Clear anodized finish Grounding Lugs Connect arrays to equipment ground. • Low profile • Single tool installation • Mounts in any direction Bonding Hardware Drop -in design for rapid rail Bond and attach XR Rails attachment. to roof attachments. Secure rail connections Slot for vertical adjusting Clear and black finish esign Assistant o from rough layout to fully E:Jngineered system. For free. o to IronRidge.com/design • T & Square Bolt options • Nut uses 7/16" socket • Assembled and lubricated • Self -drilling screws • Varying versions for rails • Forms secure bonding Microinverter Kits Mount Mls or POs to XR Rails. • Bonds devices to rails • Kit comes assembled • Listed to UL 2703 Flush Standoffs Raise Flush Mount System to various heights. • Works with vent flashing • 4" and 7" lengths • Ships assembled NABCEP Certified Training 0%w Earn free continuing education credits, POP while learning more about our systems. Go to IronRidge.com/training © 2016 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.30 Use IronRidge's Microinverter Kit to bond compatible microinverters and power optimizers to the racking system. Insert Microinverter Kit T-bolt into top rail slot. Place compatible microinverter or power optimizer into position and tighten hex nut to 80 in-Ibs. Q If installing in areas with ground snow loads greater than 40 psf, install MLPE devices directly next to module frame edge COMPATIBLE PRODUCTS Enphase M250-72, 250-60, M215-60, C250-72, S230, S280, IQ 6, IQ 6+, IQ IQ7, IQ 7A, IQ 7+9 IQ 7X, Q Aggregator Darfon MIG240, MIG300, G320, G640 Solar Edge P300, P320, P340, P370, P400, P405, P485, P505, P600, P700, P730, P800p, P800s, P850, P860 SMA RoofCommKit-P2-US, TS4-R Module Retrofit Kits (TS4-R-S, TS4-R-0, TS4-R-F) Tiao Tigo Access Point (TAP) TS4-R-X (where X can be F, M, O, or S) TS4-R-X-DUO (where X can be M, O, or S) TS4-A-X (where X can be F, 217, O, O-DUO, or S) AP Systems QS1, YC600 Q Remove Grounding Washer on AP Systems QS1 and YC600 inverters before installing to XR rails. Q Remove the Stainless Steel Clip on Tigo-"A" MLPE Devices before attaching to XR rails. Q Use the number of IronRidge Microinverter kits allowed by the MLPE mounting flange. Some will require 1 kit and others 2 kits. On AP systems equipment, ding Washer Two Microinverter Kits Required (80 in-Ibs) SYSTEMS USING ENPHASE MICROINVERTERS OR SUNPOWER AC MODULES IronRidge systems using approved Enphase products or SunPower modules eliminate the need for lay -in lugs and field installed equipment grounding conductors (EGC). This solution meets the requirements of UL 2703 for bonding and grounding and is included in this listing. COMPATIBLE PRODUCTS un ow r Modules with model identifier Ab-xxx-YY and InvisiMount (G5) 46mm frame; where "A" is either E, or X; "b" can be 17, 18, 19, 20, 21, or 22; and "YY" can be C-AC, D-AC, BLK-C-AC, or BLK-D-AC. Enphase Microinverters M250-72, M250-60, M215-605 C250-72, and Engage cables ETXX-240, ETXX-208, ETXX-277. Q A minimum of two inverters mounted to the same rail and connected to the same Engage cable are required. Q The microinverters or Sunpower AC modules must be used with a maximum 20 A branch rated overcurrent protection device (OCPD). Q If an AC module is removed from a circuit for maintenance, you must first disconnect AC power and then install a temporary EGC to bridge the gap by inserting an AC extension cable (or via other NEC -compliant means), in order to maintain effective ground continuity to subsequent modules. ML Use IronRidge's Microinverter Kit to bond compatible microstroage devices to the racking system. Insert Microinverter Kit T-bolt into top rail slot. Place compatible microstorage into position and tighten hex nut to 80 in-Ibs. COMPATIBLE PRODUCTS PHAZR PHAZR Devices PHAZR-X, where X is 6-12. Solpad Solpad Inverter model SI-1k Solpad Battery Storage model SB-2K Solpad Junction Box model SJB-4k Q Running a separate equipment grounding conductor to the PHAZR or Solpad devices is not required. Q If installing in areas with ground snow loads greater than 40 psf and underneath a module, install PHAZR and Solpad devices as close as possible to module frame edge. Q Solpad may only be installed on XR-100 and XR-1000 Q Solpad may only be installed with modules having a frame thickness of 35mm or greater. Q Use the number of Iron Ridge Microinverter kits allowed by the microstorage mounting flange. Some will require 1 kit and others 2 kits. FRAMELESS MODULE KITS Insert Frameless Kit T-bolt in top rail slot. Place star washer over T-bolt, allowing it to rest on top of rail. Secure module clamps with a hex nut and torque to 80 in-Ibs. COMPATIBLE PRODUCTS Sunforson Sunforson silver or black SFS-UTMC-200(B) mid and SFS-UTEC- 200(B) end clamps. Sunpreme Sunpreme silver or black mid and end clamps with part numbers 7500105X where "X" is 1, 5, 6 or 7. Ironridae IronRidge silver or black mid and end clamps with part numbers FMLS-XC-001-Y where "X" is E or M and "Y" is B or blank. 4 Follow module manufacturer's installation instructions to install the module clamps. 4 Frameless modules require using a Grounding Lug on every rail. 4 For Sunpreme Modules Only: If required to use slide prevention hardware, see Module Slide Prevention Addendum (Version 1.10). Microinverter 't (80 in-Ibs) PHAZR Solpad �- Module Clamp (80 in-Ibs) FLUSH MOUNT INSTALLATION MANUAL - 12 MODUL,r&COMPATIBILI +il The Flush Mount System may be used to ground and/or mount a PV module complying with UL 2703 only when the specific module has been evaluated for grounding and/or mounting in compliance with the included instructions. Unless otherwise noted, "xxx" refers to the module power rating and both black and silver frames are included in the certification. Amerisolar modules with 35, 40 and 50 mm frames Amerisolar AS-bYxxxZ Where "b" can be 5 or 6; "Y" can be M, P, M27, P27, M30, or P30; and 'T' can be blank, W or WB Aptos modules with 35 and 40 mm frames Aptos Solar DNA-yy-zz23-xxx Where "yy" can be 120 or 144; and "zz" can be MF or BF FAstronergy modules with 30, 35, 40, and 45 mm frames Astronergy Solar aaSMbbyyC/zz-xxx Where "aa" can be CH or A; "bb" can be 60, 66, or 72; "yy" can be blank, 10 or 12; "C" can M, P, M(BL), M-HC, M(BL)-HC, P-HC, M(DG), or M(DGT); and "zz" can be blank, HV, F-B, or F-BH ASUN modules with 35 and 40 mm frames ASU N AS U N-xxx-YYZZ-aa Where "YY" can be 60 or 72; "ZZ" can be M,or MH5; and "aa" can be blank or BB Auxin modules with 40 mm frames Auxin AXN6y6zAxxx Where "y" can be M or P; "z" can be 08, 09, 10, 11, or 12; and "A" can be F or T Axitec Modules with 35 and 40 mm frames Axitec AC-xxxY/aaZZb Where "Y" can be M, P or MH; "aa" can be blank, 125- or 156-; "ZZ" can be 54, 60, 72, 120, or 144; "b" can be S Boviet modules with 35 and 40mm frames Boviet BVM66aaYY-xxxBB Where "aa" can be 9, 10 or 12; "YY" is M or P; and "BB" can be blank or L BYD Canadian Sola CertainTeed CSUN Ecosolargy ET Solar BYD modules with 35 mm frames BYDxxxAY-ZZ Where "A" can be M6, P6, MH or PH; "Y" can be C or K; and "ZZ" can be 30 or 36 Canadian Solar modules with 30, 35 and 40 mm frames CSbY-xxxZ r Where "b" can be 1, 3 or 6; "Y" can be H, K, P, U, V, W, or X; and 'T' can be M, P, MS, PX , M-SD, P-AG, P-SD, MB-AG, PB-AG, MS -AG, or MS -SD CertainTeed modules with 35 and 40 frames CTxxxYZZ-AA Where "Y" can be M, P, or HC; "ZZ" can be 00,01, 10, or 11; and "AA" can be 01, 02, 03, or 04 Csun modules with 35 and 40 mm frames YYxxx-zzAbb Where "YY" is CSUN or SST; "zz" is blank, 60, or 72; and "A" is blank, P or M; "bb" is blank, BB, BW, or ROOF Ecosolargy modules with 35, 40, and 50 mm frames ECOxxxYzzA-bbD Where "Y" can be A, H, S, or T; "zz" can be 125 or 156; "A" can be M or P; "bb" can be 60 or 72; and "D" can be blank or B ET Solar modules with 35, 40, and 50 mm frames ET-Y6ZZxxxAA Where "Y" can be P, L, or M; "ZZ" can be 60 or 72; and "AX can be WB, WW, BB, WBG, WWG, WBAC, WBCO, WWCO, WWBCO or BBAC Flex modules with 35, 40, and 50 mm frames Flex FXS-xxxYY-ZZ; Where "YY" can be BB or BC; and "ZZ" can be MAA1 B, MAA1 W, MAB1 W, SAA1 B, SAA1 W, SAC1 B, SAC1 W, SAD1 W, SBA1 B, SBA1 W, SBC1 B, or SBC1 W FA GC L modules with 35 mm and 40 mm frames MODULE...: GCL GCL-ab/YY xxx Where "a" can be M or P; "b" can be 3 or 6; and "YY" can be 60, 72, 72H, or 72DH Gigawatt modules with 40 mm frames GigaWatt Solar GWxxxYY Where "YY" can be either PB or MB Hansol modules with 35 and 40 frames Hansol HSxxxYY-zz Where "YY" can be PB, PD, PE, TB, TD, UB, UD, or UE; and "zz" can be AH2, AN1, AN3, AN4, HV1, or JH2 Hanwha Solar modules with 40, 45, and 50 mm frames Hanwha Solar HSLaaP6-YY-1-xxxZ I Where "aa" can be either 60 or 72; "YY" can be PA or PB; and 7" can be blank or B Hanwha Q CELLS Modules with 32, 35, 40, and 42 mm frames aaYY-ZZ-xxx where "aa" can be Q. or B.; "YY" can be PLUS, PRO, PEAK, LINE PRO, LINE PLUS, PLUS DUO or PEAK DUO; and "ZZ" can be G3, G3.1, G4, G4.1, L-G2, L-G2.3, L-G3, L-G3.1, L-G3y, L-G4, L-G4.2, L-G4y, LG4.2/ Hanwha Q CELLS TAA, BFR-G3, BLK-G3, BFR-G3.1, BLK-G3.1, BFR-G4, BFR-G4.1, BFR G4.3, BLK-G4.1, G4/SC, G4.1/SC, G4.1/TAA, G4.1/MAX, BFR G4.1/TAA, BFR G4.1/MAX, BLK G4.1/TAA, BLK G4.1/SC, EC-G4.4, G5, G5/SC, BLK-G5, BLK-G5/SC, L-G5, L-G5.1, L-G5.2, L-G5.2/H, L-G5.3, G6, G6/SC, G6+, BLK-G6, L-G6, L-G6.1, L-G6.2, L-G6.3, G7, BLK-G6+, BLK-G6+/AC, BLK-G6+/SC, BLK-G7, G7.2, G8, BLK-G8, G8+, BLK-G8+ L-G7, L-G7.1, L-G7.2, L-G7.3, L-G8, L-G8.1, L-G8.2, L-G8.3, L-G8.3/BFF, L-G8.3/BFG, ML-G9 or XL-G9.3 Heliene modules with 40 mm frames FHeliene YYZZxxxA Where "YY" can be 36, 60, 72, or 96; "ZZ" can be M, P, or MBLK; and "A" can be blank, HomePV, or Bifacial HT-SAAE modules with 35 and 40 mm frames HT-SAAE HTyy-156Z-xxx Where "yy" can be 60 or 72, 'T' can be M, P, M-C, P-C, M(S), M(VS), M(V), P(V), M(V)-C, P(V)-C Hyundai modules with 33, 35, 40 and 50 mm frames Hyundai H iY-SxxxZZ "Y" "ZZ" Where can be A, D, M or S; and can be HG, HI, KI, MI, MF, MG, RI, RG, RG(BF), RG(BK), SG, TI, or TG Itek Modules with 40 and 50 mm frames Itek IT-xxx-YY Where "YY" can be blank, HE, or SE, or SE72 JA Solar modules with 30, 35, 40 and 45 mm frames JAyyzz-bbww-xxx/aa JA Solar Where "yy" can be M, P, M6 or P6; "zz" can be blank, (K), (L), (R), (V), (BK), (FA), (TG), (FA)(R), (L)(BK), (L) (TG), (R)(BK), (R)(TG), (V)(BK), (BK)(TG), or (L)(BK)(TG); "bb" can be 48, 60, or 72; "ww" can be D09, S01, S02, S03, S06, S09, S10, or S12; and "aa" can be BP, MP, SI, SC, PR, 31313, 4BB, 4BB/RE, 566 Jinko modules with 35 and 40 mm frames J KMYxxxZZ-aa Jinko Where "Y" can either be blank or S; "ZZ" can be M, P, or PP; and "aa" can be blank, 60, 6013, 60H, 60L, 6013L, 60HL, 60HBL, 60-J4, 6013-J4, 6013-EP, 60(Plus), 604, 60-MX, 72, 72-V, 72H-V, 72L-V, 72HL-V, 72-MX, 72H-BDVP, or 72HL-TV Kyocera Modules with 46mm frames KYxxxZZ-AA Kyocera Where "Y" can be D or U; "ZZ" can be blank, GX, or SX; and "AA" can be LPU, LFU, UPU, LPS, LPB, LFB, LFBS, LF132, LPB2, 3AC, 313C, 3FC, 4AC, 413C, 4FC, 4UC, 5AC, 513C, 5FC, 5UC, 613C, 6FC, 813C, 6MCA, or 6MPA LG modules with 35, 40, and 46 mm frames LG LGxxxYaZ-bb Where "Y" can be A, E, N, Q, S; "a" can be 1 or 2; 'T' can be C, K, T, or W; and "bb" can be A3, A5, B3, G3, G4, J5, K4, or V5 Longi modules with 30, 35 and 40 mm frames Longi LRa-YYZZ-xxxM "a" "YY" "ZZ" Where can be 4 or 6; can be blank, 60 or 72; and can be blank, BK, BP, HV, PB, PE, PH, HBD, HPB, or HPH �ilr Mission Solar modules with 33 and 40 mm frames Mission Solar MSEbbxxxZZaa Where "bb" can be blank or 60A; "ZZ" can be blank, MM, SE, SO, SQ , SR, or TS; and "aa" can be blank, 1 J, 4J, 4S, 5K, 5T, 60, 6J, 6S, 6W, 8K, 8T, or 9S Mitsubishi modules with 46 mm frames Mitsubishi PV-MYYxxxZZ Where "YY" can be LE or JE; and "ZZ" can be either HD, HD2, or FB Motech IM and XS series modules with 40, 45, and 50 mm frames Neo Solar Power modules with 35 mm frames Neo Solar Power D6YxxxZZaa Where "Y" can be M or P; "ZZ" can be B3A, B4A, E3A, E4A, 1-13A, H4A; and "aa" can be blank, (TF), ME or ME (TF) Panasonic modules with 35 and 40 mm frames Panasonic VBHNxxxYYzzA Where "YY" can be either KA, RA, SA or ZA; "zz" can be either 01, 02, 03, 04, 06, 06B, 11, 11 B, 15, 15B, 16, 16B, 17, or 18; and "A" can be blank, E, G, or N Peimar modules with 40 mm frames Peimar SbxxxYzz Where "b" can be G, M or P; "Y" can be M or P; and "zz" can be blank, (BF) or (FB) Philadelphia modules with 35 and 40 mm frames Philadelphia Solar PS-YzzAA-xxx Where "Y" can be M or P; "zz" can be 60 or 72; and "AX can be blank or (BF) Phono Solar modules with 35, 40, and 45 mm frames Phono Solar PSxxxY-ZZ/A Where "Y" can be M, M1, MH, or M1 H or P; "ZZ" can be 20 or 24; and "A" can be F, T, U, or TH Recom modules with 35 and 40 mm frames Recom RCM-xxx-6yy Where "yy" can be MA or MB REC modules with 30, 38 and 45 mm frames REC Solar RECxxxYYZZ Where "YY" can be AA, M, NP, PE, PE72, TP, TP2, TP2M, TP2SM, or TP2S; and "ZZ" can be blank, Black, BLK, BLK2, SLV, or 72 ' ReneSola modules with 35, 40 and 50 mm frames Renesola AAxxxY-ZZ Where "AA" can be SPM(SLP) or JC; "Y" can be blank, F, M or S; and "ZZ" can be blank, Ab, Ab-b, Abh, Abh-b, Abv, Abv-b, Bb, Bb-b, Bbh, Bbh-b, Bbv, Bbv-b, Db, Db-b, or 24/Bb Risen S-Energy Renogy Modules with 40 and 50 mm frames RNG-xxxY Where "xxx" is the module power rating; and "Y" can be D or P Risen Modules with 35 and 40 mm frames RSMyy-6-xxxZZ Where "yy" can be 60, 72, 120 or 144; and "ZZ" can be M or P S-Energy modules with 40 frames SNxxxY-ZZ Where "Y" can be M or P; and "ZZ" can be 10, or 15 Seraphim modules with 35 and 40 mm frames Seraphim Energy SEG-aYY-xxxZZ Group Where "a" can be blank, 6 or B; "YY" can be blank, MA, MB, PA, or PB; and "ZZ" can be blank, BB, BG, BW, HV, WB, WW, BMB, BMB-HV Seraphim modules with 40 and 50 mm frames Seraphim USA SRP-xxx-6YY Where "xxx" is the module power rating; and "YY" can be MA, MB, PA, PB, QA-XX-XX, and QB-XX-XX Sharp modules with 35 and 40 mm frames Sharp N UYYxxx Where "YY" can be SA or SC Silfab Modules with 38 mm frames Silfab SYY-Z-xxxAb Where "YY" can be IL, SA, LA, SG or LG; "Z" can be blank, M, P, or X; "A" can be blank, B, H, M, or N; and "b" can be A, L, G, or T Solaria modules with 40 mm frames Solaria PowerXT xxxY-ZZ Where "Y" can be R or C; and "ZZ" can be AC, BD, BX, BY, PD, PM, PM -AC, PX, PZ, WX or WZ Solarcity modules with 40 mm frames Solarcity (Testa) SCxxxYY Where "YY" can be blank, B1 or B2 SolarTech modules with 42 mm frames SolarTech STU-xxxYY Where "YY" can be PERC or HJT SolarWorld Sunmodule Plus, Protect, Bisun, XL, Bisun XL, may be followed by mono, poly, duo, black, bk, or SolarWorld AG clear; modules with 31, 33 or 46 mm frames SW-xxx SolarWorld Sunmodule Plus, Protect, Bisun, XL, Bisun XL, may be followed by mono, poly, duo, black, bk, or SolarWorld Americas clear; modules with 33 mm frames I SWA-xxx Stion SunEdison I Suniva r Sunpower Sunspark Suntech Stion Thin film modules with 35 mm frames STO-xxx or STO-xxxA SunEdison Modules with 35, 40 & 50 mm frames SE-YxxxZABCDE Where "Y" can be B, F, H, P, R, or Z; "Z" can be 0 or 4; "A" can be B,C,D,E,H,I,J,K,L,M, or N ; "B" can be B or W; "C" can be A or C; "D" can be 3, 7, 8, or 9; and "E" can be 0, 1 or 2 Suniva modules with 35, 38, 40, 46, and 50 mm frames O PTxxx-AA-B-YYY-Z MVXxxx-AA-B-YYY-Z Where "AA" is either 60 or 72; "B" is either 4 or 5; "YYY" is either 100,101,700,1 BO, or 1 B1; and "Z" is blank or B Sunpower standard (G3 or G4) or InvisiMount (G5) 40 and 46 mm frames SPR-Zb-xxx-YY Where "Z" is either A, E, P or X; "b" can be blank, 17, 18, 19, 20, 21, or 22; and "YY" can be blank, BILK, COM, C-AC, D-AC, E-AC, G-AC, BLK-C-AC, or BLK-D-AC Sunspark modules with 40 mm frames SYY-xxxZ Where "YY" can be MX or ST, and "Z" can be M, P or W Suntech Modules with 35, 40 and 50mm frames STPxxxy-zz/aa Where "y" is blank or S; and "zz" can be 20, 24; and "aa" can be Vd, Vern, Vfw, Wdb, Wde or Wd Talesun modules with 35 and 40 frames TP6yZZaaxxx-b Where "yy" can be blank, F or H; "ZZ" can be 60 or 72; "aa" can be M or P; and "b" can be blank, B, T, or (H) Trina Modules with 30, 35, 40 and 46mm frames TSM-xxxYYZZ Where "YY" can be DD05, DD06, DD14, DE14, DE15, DEG15, PA05, PC05, PD05, PD06, PAK PC14, PD14, PE14, or PE15 ; and "ZZ" can be blank, .05, .08, .10, .18, .08D, .18D, 0.82, .002, .00S, 05S, 08S, A, A.05, A.08, A.10, A.18, A(II), A.05(II), A.08(II), A.082(II), A.10(II), A.18(II), H, H(II), H.05(II), H.08(II), HC.20(II), HC.20(II), or M URE modules with 35 mm frames DyZxxxHaa Where "y" can be 6 or 7; "Z" can be K or M; and "aa" can be H3A, H4A, or H8A Vikram solar modules with 40 mm frames VSyy.ZZ.AAA. bb Where "yy" can be M, P, MBB, MH, MS, MHBB, or PBB; rating; and "bb" can be 03.04 or 05 "ZZ" can be 60 or 72; "AAA" is the module power MODULEilr VSUN modules with 35 and 40 mm frames VSUN VSUNxxx-YYz-aa Where "YY" can be 60, 72, 120, or 144; "z" can be M, P, MH, PH, or BMH; and "aa" can be blank, BB, or DG Winaico modules with 35 and 40 mm frames Winaico Wsy-xxxZa Where "y" can be either P or T, "Z" can be either M, P, or MX; and "a" can be blank or 6 Yingli Panda, YGE, YGE-U, and YLM series modules with 35, 40, and 50 mm frames ZNShine Modules with 30, 35, and 40mm frames ZNShine ZXy6-ZZaa-xxx/b Where "y" can be M or P; "ZZ" can be blank, H, HLD, HLDD, LID, LDD, NH, NHLD or NHLDD; "aa" can be 60, 72, 120 or 144; and "b" can be M or P FRAMELESS•D_ Astronergy Solar Astronergy frameless modules CHSM6610P(DG)-xxx Canadian Solar frameless modules Canadian Solar CSbY-xxx-Z Where "b" can be 3 or 6; "Y" is K, P, U, or X; and "Z" can be M-FG, MS-FG, P-FG, MB-FG, or PB-FG Jinko Jinko frameless modules JKMxxxPP-DV Prism Solar frameless modules Prism Solar BiYY-xxxBSTC Where "YY" can be 48, 60, 60S, 72 or 72S Risen frameless modules Risen RSMyy-6-xxxZZ Where "yy" can be 60, 72, 120 or 144; and "ZZ" can be MDG or PDG Stion Stion frameless modules STL-xxx or STL-xxxA Sunpreme frameless modules Sunpreme GXB-xxxYY Where "YY" can be blank or SL Trina frameless modules Tri n a TSM-xxxYY Where "YY" can be either DEG5(II), DEG5.07(II), DEG5.40(II), DEG5.47(II), DEG14(II), DEG14C(II), DE- G14C.07(II), DEG14.40(II), PEGS, PEG5.07, PEG5.40, PEG5.47, PEG14, or PEG14.40