BLD2021-0529_Comment_Response_Letter__4.13.2021_9.00.33_AM_2142057SOLAR PV SYSTEM DETAILS TOTAL MODULE(S) 40 TOTAL DC POWER 13.6kW OPERATING VOLTAGE 240V MAX AC POWER OUT 11.62kVA PV STRING SIZING DETAILS INVERTER TOTAL 40 SYSTEM AC OUTOUT 48.40A MAX MICROINVERTERS IN STRING 10 MAX CONTINUOUS AC OUTPUT IN STRING 12.10A MODULE DATA HANWHA Q.PEAK MODEL BLK-G6+/AC 340 MPP VOLTAGE 33.94V MPP CURRENT 10.02A OPEN CIRCUIT VOLTAGE 40.7V SHORT CIRCUIT CURRENT 10.52A VOC TEMP COEFF -0.27%/°C MIN DESIGN TEMP -10°C INVERTER DATA ENPHASE INVERTER IQ7PLUS-72-2-US MAX DC INPUT 60V MAX INPUT CURRENT 15A MAX CONTINUOUS 290VA OUTPUT POWER MAX CONTINUOUS OUTPUT CURRENT 1.21A fm I MI STRING ( OO 10MODULES S CONDUIT AMPERAGE CALCULATIONS WIRE TYPE #12 THWN-2 ALLOWABLE AMPERAGE 30A CURRENT CARRYING CONDUCTORS 8 ADJUSTMENT FACTOR NEC 2017310.15(B)(3)(1) 70% STRING AMPERAGE COMPLIANCE 15.1<21.0A OVERCURRENT PROTECTION 125% OF STRING MAX AC OUTPUT NEC201721020 15.13A 125 % OF SYSTEM MAX AC OUTPUTNEC 2017210.zo I 60.50A STRING BREAKER SIZE 20A PV BREAKER SIZE N/A SOLAR INTERCONNECTION CALCULATIONS UTILITY PV BUSBAR RATING TOTAL SUPPLY % 200A OA 200A 100% <_120% FEEDER SCHEDULE ( ENPHASE Q CABLES + #6 BARE EGC IN OPEN AIR (8) #12 THWN-2 +(1) #8 GND IN 3/4" EMT CONDUIT Q (2) #4 THWN-2 +(1) #4 THWN-2 NEUT +(1) #8 GND IN 1"EMT ® (2) #4 THWN-2 +(1) #4 THWN-2 NEUT +(1) #8 GND IN 1" PVC GENERAL LINE DIAGRAM NOTES: 1. ENPHASE COMBINER PANEL CO -LOCATED WITH NET METER 2. ENPHASE IQ7+ MICROINVERTERS UL LISTED IN COMPLIANCE WITH NEC 2017 690.12 (RSD COMPLIANT) FLAG NOTES: (2) CT LEADS, LEAD WIRE 18AWG IN 1/2" EMT CONDUIT CIRCUIT INSTALLED FOR EV, (2) #8 THWN-2 +(1) #8 THWN-2 NEUT +(1) #10 GND IN 3/4" EMT MAIN BONDING JUMPER, LINE SIDE TAP BEFORE MAIN BREAKER WITH ILSCO IPC KUP-L-TAP, INSIDE MAIN PANEL IN COMPLIANCE WITH NEC 705.12(A) LEGEND BREAKER EA SOLAR MODULE JUNCTION BOX NET METER Mi IQ7+ MICROINVERTER GROUNDING FUSED DISCONNECT CURRENT TRANSFORMER ENPHASE COMBINER PANEL 80A, 240V FUSED AC MI MI DISCONNECT STRING O O 20A 100A, 70A FUSES OF 10 MODULES O O UTILITY 20A SERVICE 20A o MI MI 20A STRING OF O ^ 200A 10 MODULES 10A MAIN 50A PANEL SOLAR _ MI MI MONITORING STRING OF OO DEVICE -- 10 MODULES rr-11 PUGET SOUND SOL 805 Rainier Ave S Seattle, WA 98144 Tel: 206-706-1931 W X mod, 0oa oak �o z� =oo ova t� ��o UOCO d � 0 0�a z� oza 3 1�i1 dog 0 boy 0- Boa o 3u� c � F U 0 PRELIMINARY DESIGN 4/5~2021 REV DESCRIPTION DATE DRAWN BY AY CHECKED BY AL SOLAR NEXUS #: 13182 SALES: JEFF ROSS PM: BILL ULSUND PM CELL: (253) 951-0385 ELECTRICAL ONE LINE DIAGRAM ROOF EXTERIOR EXISTING PV-102