Loading...
BLD2021-0696_Manufacturer_Specifications_and_Installation_Instructions_5.20.2021_7.39.39_AM_2207468Amof iew s7itqd&rd® HEATING & AIR CONDITIONING Submittal Split System Cooling 4A7A6036J1000A Note: "Graphics in this document are for representation only. Actual model may differ in appearance." TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. January 2016 4A7A6036J-SUB-1 B-EN ��IngersollRand S H EATING & Al R CONDITIONING SERVICE PANEL ELECTRICAL AND REF COMPONENT CLEARANC PER PREVAILING COD TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524 (5 FEET) ABOVE UNIT. UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 305 (12") FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED. ELECTRICAL SERVI PAN 22.2 (7/8) D LOW 28.6 (1-1/8) DIA. 1 22.2 (7/8) DIA. HOLE II BOX BOTTOM FOR El POW[ LIQUID LINE SERVIC 'E' I.D. FEMALE BR CONNECTION WITH 1/4" SAE FLARE PRESSURE TAP FITTINGS. GAS LINE 1/4 TURN BALL SERVICE VALVE, 'D" I.D. FEMALE BRAZED CONNECTION WITH 1/4' SAE FLARE PRESSURE TAP FITTING. Model Base A B C D E F G H J K 4A7A60363 4 943 946 870 3/4 3/8 143 98 219 86 508 (37-1/8) (37-1/4) (34-1/4) (5-5/8) (3-7/8) (8-5/8) (3-3/8) (20) SOUND POWER LEVEL Model A -Weighted Sound Power Level [dB(A) ] Full Octave Sound Power [dB] 63 Hz* 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4A7A60363 71 78 72 69 68 66 61 58 53 Note: Rated in accordance with AHRI Standard 270-2008 *For Reference Only 4A7A6036J-SUB-1 B-EN S H EATING & Al R CONDITIONING Product Specifications OUTDOOR UNIT (a) (b) 4A7A603631000A POWER CONNS. — V/PH/HZ (c) 208/230/1/60 MIN. BRCH. CIR. AMPACITY 18 BR. CIR. PROT. RTG. — MAX. (AMPS) 30 COMPRESSOR DURATION-_ SCROLL NO. USED — NO. STAGES I— 1 VOLTS/PH/HZ 208/230/1/60 R.L. AMPS (d)— L.R. AMPS 13.6 — 79 FACTORY INSTALLED START COMPONENTS (e) NO (Uses BAYKSKT263) INSULATION/SOUND BLANKET NO COMPRESSOR HEAT NO OUTDOOR FAN PROPELLER DIA. (IN.) — NO. USED 27.5 — 1 TYPE DRIVE — NO. SPEEDS DIRECT— 1 CFM @ 0.0 IN. W.G. M 4300 NO. MOTORS — HP 1-1/8 MOTOR SPEED R.P.M. 850 VOLTS/PH/HZ 200/230/1/60 F.L. AMPS 0.77 OUTDOOR COIL — TYPE SPINE FINT ROWS—F.P.I. 1-24 FACE AREA (SQ. FT.) 24.93 TUBE SIZE (IN.) 3/8 REFRIGERANT LBS. — R-410A (O.D. UNIT) (g) 7 LBS., 11 OZ FACTORY SUPPLIED YES LINE SIZE — IN. O.D. GAS (h) (i) 7/8 LINE SIZE — IN. O.D. LIQ. 3/8 CHARGING SPECIFICATIONS SUBCOOLING 8°F DIMENSIONS H X W X D CRATED (IN.) 42 x 35.1 x 38.7 WEIGHT SHIPPING (LBS.) 246 NET (LBS.) 212 (a) Certified in accordance with the Air -Source Unitary Air -conditioner Equipment certification program, which is based on AHRI standard 210/240. (b) Rated in accordance with AHRI standard 270. W Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers or fuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. (e) No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter. Optional kit shown. M Standard Air — Dry Coil — Outdoor (9) This value approximate. For more precise value see unit nameplate. (h) For standard, recommended linear length and lift applications, see the Subcool Charging Chart on page 5. For greater lengths and other applications, consult refrigerant piping software Pub. No. 32-3312-xx (xx denotes latest revision). (1) Trane outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit and 15 feet of tested connecting lines. If connecting line length exceeds 15 feet, then final refrigerant charge adjustment is necessary. Each additional foot over 15 feet requires 0.6 Ibs of refrigerant. See the Installer's Guide forfull charging instructions. 4A7A6036J-SUB-1 B-E N l�cP�`Ic�rti! s7 iw HEATING & AIR CONDITIONING Mechanical Specification Options General The Outdoor Units are fully charged from the factory for up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 1995. Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather -resistant powder paint finish on all louvered panels and the fan top panel. The corner panels are prepainted. All panels are subjected to our 1,000 hour salt spray test. The base is made of a CMBP-G30 weatherproof material to resist corrosion. Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and high pressure switch. High and low pressure controls are inherent to the compressor. A factory supplied liquid line drier is standard. Some models may require field installation. HEATING & AIR CONDITIONING Compressor The compressor features internal over temperature, pressure protection and total dipped hermetic motor. Other features include: Centrifugal oil pump and low vibration and noise. Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured, this system has a cooling capacity to 55°F. The addition of an evaporator defrost control permits operation to 40°F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 30°F. Thermostats —Cooling only and heat/cooling (manual and automatic change over). Sub -base to match thermostat and locking thermostat cover. Evaporator Defrost Control — See Low Ambient Cooling. ETA us (ISTEO Intertek American Standard optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, American Standard offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.americanstandardair.com. American Standard has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. 62015 American Standard Heating & Air Conditioning 4A7A6036J-SUB-1 B-EN 11 Jan 2016 / // Ingersoll Rand Supersedes 4A7A6036J-SUB-IA-EN (October 2015) (