Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2021-0697_Manufacturer_Specifications_and_Installation_Instructions_5.20.2021_9.45.16_AM_2207770
Am s f iaw Sia qda-, e id, HEATING & AIR CONDITIONING Submittal Side Discharge Variable Speed HP For coastal applications where units are installed within one (1) mile of salt water, epoxy coated models are recommended. These models have an 8 week lead time after order. Epoxy Coated Model 4A6L9048A1000A 4A6L9048A1 COTA Note: "Graphics in this document are for representation only. Actual model may differ in appearance. " March 2020 4A6L9048A-SUB-1 C-EN AAWc O Sluidae HEATING & AIR CONDITIONING Product Specifications OUTDOOR UNIT (a) (b) 4A6L9048A1XXXA POWER CONNS. — V/PH/HZ W 208-230/1/60 MIN. BIRCH. CIR. AMPACITY 31.8 BR. CIR. PROT. RTG. — MAX. (AMPS) 35 COMPRESSOR DURATION@- SCROLL NO. USED — NO. STAGES 1 —Variable VOLTS/PH/HZ 208-230/1/60 R.L. AMPS (d) — L.R. AMPS 12.4 / 48.9 FACTORY INSTALLED START COMPONENTS (a) NO INSULATION/SOUND BLANKET YES SUMP HEAT YES OUTDOOR FAN PROPELLER DIA. (IN.) — NO. USED 27.5 — 1 TYPE DRIVE — NO. SPEEDS DIRECT —VARIABLE CFM @ 0.0 IN. W.G. M 3500 NO. MOTORS — HP 1-1/2 MOTOR SPEED R.P.M. 200-1050 VOLTS/PH/HZ 325-385VDC/3/60 F.L. AMPS 2.3 OUTDOOR COIL — TYPE PLATE FIN ROWS—F.P.I. 2-16 FACE AREA (SQ. FT.) 15.02 TUBE SIZE (IN.) 5/16 REFRIGERANT LBS. — R-410A (O.D. UNIT) (g) 9 LBS, 0 OZ. FACTORY SUPPLIED YES LINE SIZE — IN. O.D. GAS (h) 7/8 LINE SIZE — IN. O.D. LIQ. 3/8 CHARGING SPECIFICATIONS SUBCOOLING COOLING MODE 10° F DIMENSIONS H X W X D CRATED (IN.) 48 x 56 x 24 UNCRATED (IN.) 42-3/4 X 47 X 17-1/2 WEIGHT SHIPPING (LBS.) 269 NET (LBS.) 245 (a) Certified in accordance with the Air -Source Unitary Air -conditioner Equipment certification program, which is based on AHRI standard 210/240. (b) Rated in accordance with AHRI standard 275. (c) Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers or fuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. M No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter. Optional kit shown. (f) Standard Air— Dry Coil — Outdoor (g) This value approximate. For more precise value see unit nameplate. (h) Reference the outdoor unit ship -with literature for refrigerant piping length and lift guidelines. Reference the refrigerant piping software pub # 32-3312-xx or refrigerant piping application guide SS- APG006-xx for long line sets or specialty applications (xx denotes latest revision). Center Mass Dimensions W2 wi Model 2 Ton 3 Ton 4/5 Ton Total Weight 206 228 247 W1 (LB) 135.63 143.03 150.35 Dim "A" 13.75 15.00 15.75 W2 (LB) 70.37 84.97 96.65 Dim "B" 26.50 25.25 24.50 4A6 L9048A-SUB-1 C-E N 4moricaw Siuidard, HEATING & AIR CONDITIONING Outline Drawing 6N9UN0 BEEEEi1EfRONI SURRWNINGNSHRUBBEERYNON LALLL�DSIDES. IOU ID LINE SERVICE VALVE, 'IF I.D. iFMALF BPAEE CONNECTION NITN I- SAE PLANE PRESSURE TAP PITTI- PANEL F H` T < TURN D,uL sERvrcE VALVE, "D- FIG.I.D. fEXALE BAAZNNARE PRESSURERIT.TAP PITTING., G ACCESS PANED II II RM E 2 AXD AFEA I6EAAX1LEARANCESIX6 CODFS.IXf SfPVICE. .D. fENALfXSAETfLAAE�[m' tAP fIiTIXG. GAS LINE SERVICE VALVE. "G" D. TENALE BRAZED COxxEC110x xllx Ill' SAE FLARE PRESSURE TAP FITTING. FIGURE I Model Base A B C D E F G H J K 4A6L9048A 4.4 1086 1194 445 22 10 60 159 (3 01 187 495 (42-3/4) (47) (17-1/2) (7/8) (3/8) (2-3/8) (6-1/4) 32) (7-11/32) (19-1/2) 4A6L9048A-SUB-1 C-E N 4&eficaw Siuida rd, HEATING & AIR CONDITIONING Sound Pressure Level Outdoor Unit Tft 5' ft Table 1. 4.0 Ton Heating Reflective Surface (Back wall) Sound Pressure Level dB (A) per ARI 275 (Max Heating) # Reflective Surfaces 3' from Property Line 5' from Property Line 7' from Property Line 9' from Property Line 0 49 44 1 520) 47 44 2 55 50 47 45 Ia) Lab tested as per the illustration shown above Table 2. 4.0 Ton Cooling Sound Pressure Level dB(A) per ARI 275 (Max Cooling) # Reflective Surfaces 3 ' from Property Line 5' from Property Line 7' from Property Line 9' from Property Line 15' from Property Line 0 51 46 43 1 540) 49 46 44 2 57 52 49 47 43 (a) Lab tested as per the illustration shown above Notes: • Measuring place: Hemi-Anechoic chamber • Sound pressure level will vary depending on a range of factors such as the construction of the particular room where the equipment is installed. • Operation sound level may differ depending on operation and ambient conditions. 4A61-9048A1 Sound Characteristics — Cooling —Heating 4 4A6 L9048A-SUB-1 C-E N 4&eficaw Siuida rd, HEATING & AIR CONDITIONING Mechanical Specification Options General The outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit, ten (10) feet of tested connecting line, and the smallest rated indoor evaporative coil match. This unit is designed to operate at outdoor ambient temperatures from 55' F to 120' F in cooling. From — 10° F to 66' F in heating. Only AHRI approved indoor matches are approved for use with these models. This outdoor unit contains the Accul-inkT^" digital communication with 2 wire connection to outdoor and Plug-n-Play set up. Casing Unit is painted with a glossy corrosion resistant finish on all panels. Refrigerant Controls Refrigeration system controls include condenser fan, high and low pressure switches. A factory supplied, field installed filter drier is standard. 4A6L9048A-SUB-1 C-EN Compressor Inverter driven scroll compressor with 35 to 100% output capacity. Noise enclosure minimizes sound levels and built in compressor protection will reduce operating speed and current draw to maintain operation while protecting the compressor. Condenser Coil The copper tube, aluminum fin outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected by a wire guard. Low Ambient Cooling As manufactured, this system has built in freeze protection that will allow cooling operation down to 45° F but will reduce capacity or shut down completely to prevent operation under adverse conditions. Comfort Control The 1050/950/850 Control is required and provides Plug-n-Play setup and 3 wire connection. A*i ew Shtodvd HEATING & AIR CONDITIONING About American Standard Heating and Air Conditioning American Standard has been creating comfortable and affordable living environments for more than a century. For more information, please visit www.americanstandardair.com. c&u s LISTED The AHRI Certified mark indicates company participation in the AHRI Certification program. For verification of individual certified products, go to ahridirectory.org. The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. 4A6L9048A-SUB-1 C-EN 19 Mar 2020 Supersedes 4A61-9048A-SUB-1 B-EN (July 2018) © 2020 American Standard Heating and Air Conditioning