BLD2020-0617+Manufacturer_Specifications_and_Installation_Instructions+6.15.2020_2.34.06_PM
Hussmwnno LEXCel a)- P2X-E Technical Data Sheet P/N 0463861 L Item Part # Description Wiring Item # Item Part # Description FAN ASSEMBLIES 8Ft& 12Ft A. 7W Standard Energy Efficient Fan Assembly (1) 0477654 Fan Motor, Evaporator (MO.4410545) 0142780 Fan Blade (FB.0142780) THERMOSTATS B. 0411744 Standard Non-adjustable Defrost Thermostat (CT.0411744) C. Optional Adjustable Refrigeration Thermostat Data sheet-Excel-P2X-E NSF® Certified October 2017 =Efficiency Wiring Item # LAMPS AND BALLASTS D. Ballast, Electronic 0480130 2 lamps (BA.4481676) 0480131 3 lamps (BA.4481654) 0480132 4 lamps (BA.4481677) E. Fluorescent Lamp Replace with like fixtures (2) LED FIXTURES AND POWER SUPPLY F. 0501213 Power Supply (EP.4481861) G. LED Canopy Fixture (3) Replace with like fixtures H. LED Shelf Fixture Replace with like fixtures c Note: Revision L: Removed 6 foot data. Other changes marked by bar, underline or circle. (4) (5) (6) (7) (8) ©2017 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-890-2900 • WWW.HUSSMANN.COM Spanish P/N 0533229 Engineering PHYSICAL DATA Merchandiser Drip Pipe (in.) 1 1/4 Plan Views Merchandiser Liquid Line (in.) 3/8 Merchandiser Suction Line (in.) 7/8 Bulk -Produce 10-2004 Dimensions shown as inches and (mm). P2X A D 3 In. B $ (203 Required R(77 mm) 41 1/2 43 7/s 41 1/2 ]14 1/2 (115) Air Gap (1054) (1114) (1054) 4 1/4 (108) 4 3/4 (120) Electrical Refrigeration Stub Up Area Outlet 26 1/4 31 5/8 42 1 1 s x s 1� 4 3/4 (120) I I I (665) (804) (1064) (612 I (152x152) I I I Waste Outlet 1 1 30 1/4 33 1/2 z r x x I -L %(768) Electrical (851) Waste Outlet LJ LJ LJ Field — — — — — — — — — — — — — — ------------- Connection Wirewav 26 1 /2 (673) Splashguard 12 1/8 (307) C NOTE: Case -to -Case Electrical Connections are made IN FRONT OF SPLASHGUARD. FRONT General 8ft 12ft (A) Case Length (without ends or partitions) 96 3/8 (2448) 144 1/2 (3670) (Each end and insulated partition adds 1 112 in. (38 mm) to case line up.) Maximum O/S dimension of case back to front (includes bumper) 42 (1064) 42 (1064) Back of case to front of splashguard 33 1/2 (851) 33 1/2 (851) Back of case to O/S edge of front leg 301/4 (768) 30 1/4 (768) Distance between edges of external legs and center legs 41 1/2 (1054) 41 1/2 (1054) Distance between edges of center legs NA 43 7/8 (1114) Distance between front legs and splashguard 2 3/4 (70) 2 3/4 (70) Electrical Service ® (Electrical Field Wiring connection point) (B) RH End of case to center of stub up area 84 1/4 (2140) 132 3/8 (3363) Back of case to center of stub up area 24 (612) 24 (612) Length of electrical wireway Wireway 26 1/2 (673) 26 1/2 (673) (C) RH End of case to LH end of wireway 901/8 (2289) 138 1/4 (3511) Waste Outlets (One each end) 0 (D) RH End of case to the center of LH waste outlet 84 1/4 (2140) 132 3/8 (3363) RH End of case to the center of RH waste outlet 12 1/8 (307) 12 1/8 (307) Back O/S of case to center of waste outlets 31 5/8 (804) 31 5/8 (804) Schedule 40 PVC drip pipe 1 1/4 (32) 1 1/4 (32) Refrigeration Outlet 0 Back of case to center of refrigeration outlet 26 1/4 (665) 26 1/4 (665) RH end of case to center of refrigeration outlet 8 (203) 8 (203) 2 Of 9 U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-890-2900 P2X-E Technical Data Sheet Multi -deck, 2 Display Levels (E 2oy Hussmann refrigerated merchandisers configured for sale for use in the United States E!�gy Efficiency Compliant meet or surpass the requirements of the DOE 2017 energy efficiency standards. P2X-E Dimensions shown as inches and (mm). 3 In. (77 mm) Required Air Gap 14 5/s (878) 7 1/4 (183) I r .Q 361/4 421/2 (920) ; (1080) 301/4 (768) oo FAN 28 5/8 Refrigeration (727) outiet i 31 (787) � 1 15 (381) 4 3/4 (122) i Electrical � Case to Case 26 1/4 (665) — Connections 301/4 (768) r 31 5/8 (804) 33 1/2 (851) - 42 (1064) C O L 74 % (1890) 16 1/4 (412) Estimated Charge** P2X-E 8 ft 2.3 lb 37 oz 1.0 kg 12 ft 3.3 lb 53 oz 1.5 kg "This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound (8 oz/0.2 kg NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability. Excel P2X-E Bulk Produce REFRIGERATION DATA Note: This data is based on store temperature and humidity that does not exceed 75°F and 55% R.H. P2X-E§ Discharge Air °F 33 Evaporator °F 24 Unit Sizing °F 22 § Average evaporator temperature shown. Use dew point for high glide refrigerants for unit sizing. Care should be taken to use the dew point in PT tables for measuring and adjusting superheat. Adjust evaporator pressure as needed to maintain discharge air temperature shown. Btu/hr/ft — Unlit Shelves I P2X-E Parallel Conventional UNLIT 949 1029 1 Add 10 Btu/hr/ft per shelf row for LED fixtures. Add 20 Btu/hr/ft per shelf row for fluorescent lamps. DEFROST DATA P2X-E Frequency (hr) 8 Defrost Water (lb/ft/day) 6 (± 15% based on case configuration and product loading). OFFTIME P2X-E Temp Term °F 48°F Failsafe Minutes 30 ELECTRIC oa GAs Not Recommended Standard Defrost Thermostat Close on rise: close 48°F — open 33°F CONVENTIONAL CONTROLS Low Pressure Backup Control P2X-E Cl/CO* 17/70F Indoor Unit Only, Pressure Defrost Termination* 48°F *Use a Temperature Pressure Chart to determine PSIG conversions. P/N 0463861_L HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM 3 of 9 Excel P2X-E Bulk Produce Electrical Data 8ft 12 ft Number of Fans - 7W 2 3 Number of Fans - 4W - - Amperes Watts 8 ft 12 ft 8 ft 12 ft Evaporator Fan 120V 50/60Hz Standard Energy Efficient 0.38 0.57 28 42 230V 50/60Hz Standard Energy Efficient 0.20 0.30 28 42 230V 60Hz Export 0.50 0.75 78 117 230V 50Hz Export 0.56 0.84 84 126 Minimum Circuit Ampacity 120V 50/60Hz Standard Energy Efficient 0.58 0.77 230V 60Hz Export 0.70 0.95 230V 50Hz Export 0.76 1.04 230V 50/60Hz Standard Energy Efficient 0.40 0.50 Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15 Standard Lighting (T-8 fluorescent) 1 Row Canopy 0.51 0.77 59 85 ONLY LIGHTING CONFIGURATIONS THAT ARE COMPLIANT WITH THE U.S. DEPT. OF ENERGY (DOE) 2017 REGULATION ARE AVAILABLE FOR SALE FOR USE IN THE U.S.A. Optional Lighting (T-8 fluorescent) Additional 1 Row Canopy 0.51 0.77 59 85 Additional 2 Row Canopy 1.02 1.54 118 170 Additional 3 Row Canopy 1.53 2.31 177 255 1 Row Rail Light 0.51 0.77 59 85 1 Row of Shelves 0.51 0.77 59 85 2 Rows of Shelves 1.02 1.54 118 170 3 Rows of Shelves 1.53 2.31 177 255 EcoShine II Canopy EcoShine II 0.46 0.70 55.6 83.4 EcoShine II HO 0.56 0.84 67.2 100.8 EcoShine II Rail Light 1 Row 0.17 0.26 20.5 30.7 EcoShine II Shelves 1 Row of Shelves 0.17 0.26 20.5 30.7 2 Rows of Shelves 0.34 0.51 40.9 61.4 3 Rows of Shelves 0.51 0.77 61.4 92.1 120V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting 120V LED Lighting Circuit Total = Canopy Lighting + Shelf Lighting + Optional Rail Lighting 230V Lighting Circuit Total = Multiply 120V Lighting Circuit Total by 0.52 Please note: some combinations of fluorescent lights on this case model may not be compliant with DOE2017 and may not be available to order in the US and Canada. More lighting options are available with LED lights. The Hussmann Product Configurator will not allow lighting options that do not comply with the DOE2017 standards. 4 of 9 U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-890-2900 P2X-E Technical Data Sheet Product Data Recommended Usable Cube 1 (Cu Ffft) AHRI Total Display Area 2 (Sq Ffft) Shelf Area 3 (Sq Ffft) Excel P2X-E Bulk Produce 6.69 ft3/ft (0.62 m3/m) 3.06 ft2/ft (0.93 m2/m) 3.87 ft2/ft (1.18 m2/m) I AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft3/ft [1n3/m] 2 Computed using AHRI 1200 standard methodology: Total Display Area, ft2 [m2]/Unit of Length, ft [m] 3 Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is (1) row of 16-inch shelf. ESTIMATED SHIPPING WEIGHT 4 Case Solid End 8 ft 12 ft (each) lb (kg) 1000 (454) 1200 (544) 75 (34) 4 Actual weights will vary according to optional kits included. P/N 0463861_L HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM 5 of 9 Fan Wiring Offtime Defrost 1,2&3Fans 8 ft — 2 Fans 120V NEUTRAL I 12 ft — 3 Fans Fans O BROWN BAND I 120V POWER I BROWN BAND Defrost O2 Refrigeration O3 Termination Thermostat Thermostat Lig t Blue Dar Blue To Condensing 8 ft 12 ft Unit Light Circuits — Fluorescent Fixtures Field Connections Connections W I Ballast -------------JI I G B1K� BK V Orange or Tan Band W � for Optional Licht Rail Standard Lighting —1 Row Canopy Optional Lighting — 2 Row Canopy — 3 Row Canopy I Connector 8 ft 12 ft BK R R Case R R Ground � 5 5 Bar BL BK=== BL BL --- -, R R W R R Optional L 5 5 Two Row ' BL Canopy BL BL -- -- --- -- ---- -- -- -- -- -------------------- -- R R-- - - --------------- ------ -------- ------ ------------------------ - ' W R R i R R Optional 5 5 Two Row BL Canopy BL BL - -------------------------------------------------- - - - - - - Optional Lighting —1 Row Rail QB Connector 8 ft 12 ft W R R R R L IEE 5 5 BL BL BL WARNING All components must have mechanical ground, and the merchandiser must be grounded. CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS R = Red Y = Yellow G = Green BL = Blue BK = Black W = White 0 = 120V POWER O = 120V NEUTRAL 1 = FIELD GROUND mim = CASE GROUND 6 of 9 U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-890-2900 P2X-E Technical Data Sheet Optional Shelf Lighting Fluorescent Fixtures Optional Shelf Harness and Light Circuits for Two Rows of Shelves I I I W w I W I wT— BK w— BK w7 BK I BK BK IBK I I 4 4 I ® I I Connector I I I I I I I R (Connector R I R BL- BL B BL I JDL- BL- BLBL I BL R 5 R�� I R BL R BL I R BLL�P[I R/�5FC I I I I I I I I I I I I 8 ft case I — — — — — — — — — — — — — — — — — — — — — — 12 ft case I I I I I — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — WARNING All components must have mechanical ground, and the merchandiser must be grounded. CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS R = Red Y = Yellow G = Green BL = Blue BK = Black W = White = 120V POWER O = 120V NEUTRAL 1 = FIELD GROUND mim = CASE GROUND P/N 0463861_L HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM 7 of 9 Optional Canopy and Rail Light Circuits — LED Fixtures EcoShine II LED Canopy Lighting —1 Row r---------------------------------n I Ballast Plug for Optional 8� Light Rail (if applied) �- BK c BK BL-4 10 W' W © R I r G Case Ground Bar Orange or 8-Ft Case Tan Band I R R I BL BL I BL— O RBL 7 I R I L— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — J r------------------------------------------------------ 1 — Ballast Plug for Optional I �... Light Rail (if applied) I I �BK' I I o-W G BKBL1; I I r Case Ground Bar W © R I I Orange or 12-Ft Case � I Tan Band I R I I BL I I R R I I BL BL I RBL RBL RBL L- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - J EcoShine II LED Rail Lighting —1 Row r—————————————————————————————————- I I I I I BK < BK BL I I �W W O R I � I I 8-Ft Case I I I R BL R BL RBL B < RBL B I L- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - J r------------------------------------------------------� I I I I I BK BK © BL I I O—W W R I � I I 12-Ft Case I I R I I BL I I R R I I BL BL I RBL $ RBL ® RBL L- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - J WARNING All components must have mechanical ground, and the merchandiser must be grounded. CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS R = Red Y = Yellow G = Green BL = Blue BK = Black W = White 9 = 120V POWER O = I20V NEUTRAL 1 = FIELD GROUND mim = CASE GROUND 8 of 9 U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-890-2900 P2X-E Technical Data Sheet Optional Shelf Lighting LED Fixtures Optional Shelf Harness and LED Light Circuits for 2 or 3 Rows of Shelves -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- I WB I d I I I I Ir I I'G BK p W BKBL Connector WLK R BL I Connector I BL I —R— BL R R IR I I �L 8 I �BL s I �BIL R $ R I R I �RL e I 1 R $ I �RL s [�R L s I I I I I Shelf Light I Plug & Receptacle 8 ft case I (TYP) 12 ft case I — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — WARNING All components must have mechanical ground, and the merchandiser must be grounded. CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS R = Red G = Green BL = Blue BK = Black W = White = 80V POWER O = 80V NEUTRAL 1 = FIELD GROUND m% = CASE GROUND P/N 0463861_L HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM 9 of 9