Water Availability - 328 348 3rd Ave - Signedt:n4f
WATER AVAILABILITY
CERTIFICATE
PERMITTING & DEVELOPMENT
ENGINEERING
DIVISION
121 5th Avenue N
P: 425.771.0220
www.ednnondswa.aov
ITEMS IN THIS BOX TO BE FILLED IN BY APPLICANT
® Building Permit ❑ Preliminary Plat or PUD
❑ Subdivision ❑ Rezone or Other
Applicant's name: Jigsaw Real Estate / John Jackels
Proposed Use: 16 Townhouses
Location (attach map and legal description if necessary): 328/348 P Ave. S
Updated on 811412018 Page] of 2
ITEMS IN THIS BOX TO BE FILLED IN BY EDMONDS DEVELOPMENT SERVICES DEPARTMENT
Permit Number
PRE2021-0005
Project Name
328/348 3rd Ave S Townhomes
INFORMATION PROVIDED BY WATER AGENCY
1.
® a. Water will be provided by service connection only to an existing 8-inch (size) water
main that is ad'acent to the site.
OR
❑ b. Water service will require an improvement to the water system of:
❑ (1). feet of water main to reach the site; and/or
❑ (2). The construction of a distribution system on the site; and/or
❑ ( ).Other(describe):
z.
® a. The water system is in conformance with a City approved water comprehensive plan.
OR
❑ b. The water system improvement will require a water comprehensive plan amendment.
(This will cause a delay in permit issuance and approval.)
I
❑x a. The proposed project is within the corporate limits of the City, or has been granted Boundary
Review board approval for extension of service outside the City, or is within the City approved
service area of a private water purveyor.
OR
❑ b. Annexation or Boundary Review Board approval will be necessary to provide service.
4.
® a. Water is/or will be available at the rate of flow and duration indicated below at no less than zo psi
Measured at the nearest fire hydrant 70 feet from the building/property (or as marked on attached map)
Rate of Flow Duration
❑
Less than Soo gpm. (approximately gpm) ❑ Less than one (i) hour
❑
500 to 999 gpm ❑ One (1) to two (2) hours
❑
1500 gpm or more Two (z) hours or more
El
Flow test of gpm ❑ Other
®
Calculation of 2855 gpm (Commercial building permits require flow test or calculation)
OR
❑ b. Water will system is not capable of providing fire flow.
WATER AGENCY CERTIFICATION
COMMENTS/CONDITIONS: Per model Static Pressure is 3.3.6.psi
at s000 qpm, residual ressure is 11 si
at max flow of 28SS gpm, residual pressure is q6.4o psi
I hereby certify that the above water purveyor information is true. This certification shall be valid for
one year from date of signature.
City of Edmonds Russell Lynch
(Agency Name) :Signatory Printed ame l
Associate Engineer
(Title) (Signature/Date)
Updated on 811412018 Page 2 of 2