Loading...
ENG2021-0182 ROW PERMITOF WAY EUC PERMIT PERMITNUMBER, City of Edmonds EdmondsRIGHT 98020 1 1 www.cityofedmonds.gov Description: PUD - REPAIR SIDEWALK ISSUED: 05/25/2021 Address: 117 5TH AVE S EDMONDS WA 98020-3423 EXPIRES: 11/24/2021 rmit Type: RIGHT OF WAY EUC Permit Subtype: STANDARD Parcel Number: 00434212003900 I 11141 a i i NAME TYPE NAME ADDRESS PHONE APPLICANT SNOHOMISH COUNTY PUD P.O. BOX 1107, EVERETT WA 98206 (425)670-3216 CONTRACTOR SNOHOMISH COUNTY PUD P.O. BOX 1107, EVERETT WA 98206 (425)670-3216 OWNER JD YOUNG LLC 1916 N 49TH ST, SEATTLE WA 98103 FEE INFORMATION DESCRIPTION AMOUNT PAID CITY TECHNOLOGY FEE CHARGED PER PERMIT $40.00 $0.00 ENGINEERING INSPECTION FEE $220.00 $0.00 RIGHT OF WAY STANDARD - EUC PERMIT FEE $330.00 $0.00 • REQUIREMENT TYPE NOTES TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their posession. RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday - No Exceptions WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final inspection and acceptance of the work. INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM 24 HR NOTICE REQUIRED INDEMNITY The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of granting this permit. RELEASED BY THIS DOCUMENT IS NOT VALID UNTIL FEES ARE PAID AND THE CITY ENGINEER OR HIS/HER DEPUTY HAS SIGNED BELOW DATE Printed: Tuesday, May 25, 2021 11:36:16 AM 1 of 2 -KRWOF WAY EUC PERMIT City of • • • Edmonds•:• •ENG2021-018 www.cityofedmonds. ov/425.771.0220 CONDITIONS CONDITION TYPE Easement and/or permission from adjacent property owner is required prior to entry or work within ADJACENT PROPERTY an adjacent property. It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in DAMAGE TO FRONTAGE City right of Ways or Easements to City Standards caused by or occurring during the permitted IMPROVEMENTS project. Alert affected residents and/or businesses prior to work start. Verify clear bore crossings. ENGINEERING OTHER Restore landscape to like or better conditions. Call for required inspections as noted. ESC REQ Maintain erosion and sedimentation control per City and SWMMW standard requirements. Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly from the HOLD HARMLESS issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. Concrete sidewalk shall meet the City's requirement - 3000 psi commercial mix per WSDOT 6-02.3(2)B (see standard detail TR-531). If mix that PUD proposes to use is not installed properly or there are OTHER CONDITION issues with it setting after installation, PUD will be responsible for replacing any panel(s) that do not meet City standards. Sound/Noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:OOam to 6:OOpm on SOUND OR NOISE weekdays and 10:OOam and 6:OOpm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. All utilities shall be located prior to any excavation. New locates shall be called for if at time of UTILITY LOCATES excavation, original locates are no longer identifiable. Is INSPECTION TYPE DATE RESULT NOTES T 11 COMPLETE A-1 JOB START X-2 ENGINEERING FINAL" E-7 TRAFFIC CTRL E-7 CONCRETE SIDEWALK Printed: Tuesday, May 25, 2021 11:36:16 AM 2 of 2 of EpM04O� 100034595 RIGHT OF WAY CONSTRUCTION ENG2021-0182 PERMIT APPLICATION Complete and submit this Application in accordance with the Submittal RECEIVED '1 r. is') Requirements outlined in Right -of -Way permit Handout E6�. MAY 19 2021 If any field is not applicable to your project, write "N/A' instead of leaving blank. All fields required. Incomplete Applications will be denied. CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SECTION A General • Project Name Dayton Street Utility Replacement Project - 5th Sidewalk Site Address or if no site address use Property Address at NW corner of project area: 117 5th Ave S, Edmonds Associated Permits: BLD PLN ENG Owner and Entity Holding Name of Company Snohomish County PUD (same as below) Franchise Ordinance No: Point of Contact Title Address City State Zip Phone Email Contractor and Authorized Agent of Owner (see note below) Name of Company Snohomish County PUD Contractor Contacts During Construction Primary Name Curt Christensen Agent Name Beth Haskin Title Restoration Crew Lead Title Joint Use and Permit Administrator Mobile 425-783-568o Address PO Box 1107 Email CDChristensen@snopud.com City Everett State WA Zip 98201 Secondary Name Phone 425-783-4315 Title Email JointUse@snopud.com BAHaskin@snopud.com Mobile City of Edmonds Business License No: Email State License No: pJ Contractor verifies it is currently bonded ® Contractor verifies it currently has general liability insurance NOTE: ECDC 18.6o. o2o requires that the Application be signed by a licensed and bonded contractor unless otherwise approved by the city engineer. ❑ Multifamily residential ❑ Commercial 2g City project ❑ Single family residential subdivision ❑ Single family -other ❑ Industrial ❑ Demo and rebuild or from vacant land? ❑ Other, please specify: ❑ Utility Franchise Work associated with development (check one of the above boxes as welt ® Traffic Control Only (no associated development) ❑ Utility Franchise Work (no associated development) City of Edmonds ROW construction permit Application --Page 1 of 3 Updated 3/25/2021 Include an overall narrative description of the proposed work. Be specific and detailed: Describe infrastructure to be impacted, such as, poles, wires, conduit, utility mains, etc. Include whether this is construction, maintenance, or repair. Include description of proposed construction methods, (e.g., bores, trenches, overhead wires proposed, depth for underground utilities, etc.) Repair the sidewalk in front of 117 5th Ave S, Edmonds. Utility transformer lid was replaced but concrete sidewalk restoration needs to be completed. The east sidewalk of 5th Ave S between Main St and Dayton St will need to be closed during work and sidewalk detours will be provided at Main & 5th and Dayton & 5th. RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (Number of Months) Sidewalk 72 hours + LF I x LF SF Alley 72 hours + LF Ix I LF SF Parking 72 hours + LF Ix I LF SF SECTION B - If you are not a utility company performing work in the City ROW, skip to SECTION C. 1. The work in the right of way is on or for the following type of facilities: ❑ telecommunications ❑ cable ® power ❑ gas ❑ water ❑ sewer ❑ storm Details of Work to be Completed 1. Does the utility owner have existing overhead infrastructure in the area of work? Yes No X 2. Will any equipment be added underground or above ground (e.. pedestals, vaults, etc.)? X If yes, describe: 3. Does the proposed work connect a lot or commercial development with utilities that serve more than one lot or commercial development? X 4. Does the work involve rebuilding or relocating an existing aboveground utility system which connects a lot or commercial development to an existing underground common utility stem? X 5. Does the work involve proposed additions to an aboveground utility stem? If es: X Are the additions for the purpose of serving new commercial development? Are the additions for the purpose of serving a single-family residential subdivision? Details of Work to be Completed Yes No 6. Does your project involve rebuilding or replacing utility equipment which currently serves more than one lot or commercial development? X If yes, answer the following questions related to project area, i.e. the actual area in which the project is proposed: 6a. Does your project involve wires/cables/lines? If yes: X How many are existing? I I How many are to be added? City of Edmonds ROW construction permit Application --Page 2 of 3 Updated 3/25/2021 6b. Does your project involve poles? If yes: X How many poles are existing in the project area? What is the height of the existing poles? How many poles are to be removed? Are additional poles to be laced? How many? I I What is the height of the additionalpoles? 6c. Are any poles to be modified/rebuilt/replaced? If yes: X How many? I I What is the height of the poles after? Describe the modification rebuild: SECTION C Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their possession. Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS. Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to any permit approval. Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials, officers, employees, and agents against any injuries, damages, or claims of any kind or description whatsoever, foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectly from any act or omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose acts or omissions they may be liable, arising out of, related to, or by reason of the granting of this permit; and specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the expiration, revocation, or termination of any resulting permit approval. Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and requirements set forth in this Application and agrees they apply to any resulting permit and shall comply with them to the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable requirements of state and federal law. Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a licensed and bonded contractor; the information provided herein is correct and complete; and I am authorized by owner to act on its behalf and have authority to bind the owner to this application. Fees. The Applicant is responsible for all permit fees. APPLICANT SIGNATURE: Ka.&"' DATE: 5/19/2021 APPLICANT PRINTED NAME: Kallen Shaug nessy- ndall APPLICANT TITLE: Engineer NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE City of Edmonds ROW construction permit Application --Page 3 of 3 Updated 3/25/2021 Concrete sidewalk shall meet the City's requirement - 3000 psi commercial mix per WSDOT 6-02.3(2)B (see attached SIDEWALK standard detail TR-531). If mix (PEDESTRIAN that PUD proposes to use is not installed properly or there are issues with it setting after installation, PUD will be responsible for replacing any panel(s) that do not meet City standards. Main St ENGINEERING DIVISION APPROVED AS NOTED 05/25/2021 Dayton St Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. (n Q) Q CLOSURE DETOUR) RECEIVED MAY 19 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT HAVE BARRICADES NOT ENTIRELY BLOCK SIDEWALK SO ACCESS TO BUSINESSES ON EITHER SIDE OF JOB SITE CAN REMAIN OPEN. SIDEWALK CLOSED SP-6 USE OTHER SIDE SIDEWALK CLOSED AHEAD - CROSS HERE. BARRICADE, TYP SIDEWALK CLOSED SUIDWALK CLOSED SP-5 SIDEWALK CLOSED AHEAD - CROSS HERE. OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE w P Concrete sidewalk shall meet the City's requirement - 3000 psi commercial mix per WSDOT 6-02.3(2)B (see attached standard detail TR-531). If mix that PUD proposes to use is not installed properly or there are issues with it setting after installation, PUD will be responsible for replacing any panel(s) that do not meet City standards. RECEIVED MAY 19 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 1/2" FULL DEPTH 10' EXPANSION JOINT DUMMY JOINT d a v a d d d a v d a a � d a a a d a a 10' O.C. 5' O.C. PLAN VIEW (NOT TO SCALE) 1' 5' MIN MIN. 2% MAX FULL DEPTH 1/2" EXPANSION CURB/GUTTER SEE COE STD JOINT MATERIAL ?1i DTL TR-520 2% MAX a ?�M a 1 /.2„ R d v a a a as as ao as as as aa�J a 2" MIN 5/8" MINUS CSTC ON SEE NOTES 4 & 5 NATIVE SUBGRADE BEARING SOIL SEE NOTE 9 SECTION VIEW NOTES: (NOT TO SCALE) 1 /8" TO 1 /4" 1. CITY INSPECTION REQUIRED ON FORM WORK PRIOR TO POUR. 2. CONCRETE SHALL BE CLASS 3000/COMMERCIAL MIX. o a l 1/2" 3. FINISH SHALL BE LIGHT BROOM. DUMMY JOINT 4. SIDEWALK THICKNESS SHALL BE 4". (NOT TO SCALE) 5. SIDEWALK THICKNESS AT DRIVEWAYS AND DRIVEWAY TRANSITIONS SHALL BE 6". 6. CURB AND GUTTER SHALL BE POURED SEPARATELY FROM SIDEWALK. 7. LIDS FOR JUNCTION BOXES AND UTILITY VAULTS SHALL BE NON—SKID AS SPECIFIED BY ENGINEER. 8. SEE COE STD DTL TR-550 FOR POSSIBLE ROOT BARRIER INSTALLATION. 9. NATIVE SUBGRADE BEARING SOIL AND CSTC SHALL BE COMPACTED TO 95% MAXIMUM DENSITY. 10. ALL EDGES AND JOINTS SHALL HAVE 1/2" RADIUS REVISION DATE CITY OF EDMONDS APRIL 2021 CONCRETE SIDEWALK PUBLIC WORKS STANDARD DEPARTMENT DETAIL FS t . 18 9� APPROVED BY: R. ENGLISH T R — 5 31