ENG2021-0182 ROW PERMITOF WAY EUC PERMIT
PERMITNUMBER,
City of Edmonds
EdmondsRIGHT
98020 1 1
www.cityofedmonds.gov
Description: PUD - REPAIR SIDEWALK ISSUED: 05/25/2021
Address: 117 5TH AVE S EDMONDS WA 98020-3423
EXPIRES: 11/24/2021
rmit Type: RIGHT OF WAY EUC Permit Subtype: STANDARD Parcel Number: 00434212003900
I 11141 a i
i
NAME TYPE NAME ADDRESS PHONE
APPLICANT SNOHOMISH COUNTY PUD P.O. BOX 1107, EVERETT WA 98206 (425)670-3216
CONTRACTOR SNOHOMISH COUNTY PUD P.O. BOX 1107, EVERETT WA 98206 (425)670-3216
OWNER JD YOUNG LLC 1916 N 49TH ST, SEATTLE WA 98103
FEE INFORMATION
DESCRIPTION AMOUNT PAID
CITY TECHNOLOGY FEE CHARGED PER PERMIT
$40.00 $0.00
ENGINEERING INSPECTION FEE
$220.00 $0.00
RIGHT OF WAY STANDARD - EUC PERMIT FEE
$330.00 $0.00
•
REQUIREMENT TYPE
NOTES
TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City
Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification
verifying completion of the required training in their posession.
RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with
asphalt or City approved material prior to the end of the workday - No Exceptions
WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final
inspection and acceptance of the work.
INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM
24 HR NOTICE REQUIRED
INDEMNITY
The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of
any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments
or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of
granting this permit.
RELEASED BY
THIS DOCUMENT IS NOT VALID UNTIL FEES ARE PAID AND THE CITY ENGINEER OR HIS/HER DEPUTY HAS SIGNED BELOW
DATE
Printed: Tuesday, May 25, 2021 11:36:16 AM 1 of 2
-KRWOF WAY EUC PERMIT
City of • • •
Edmonds•:• •ENG2021-018
www.cityofedmonds. ov/425.771.0220
CONDITIONS
CONDITION TYPE
Easement and/or permission from adjacent property owner is required prior to entry or work within
ADJACENT PROPERTY
an adjacent property.
It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in
DAMAGE TO FRONTAGE
City right of Ways or Easements to City Standards caused by or occurring during the permitted
IMPROVEMENTS
project.
Alert affected residents and/or businesses prior to work start.
Verify clear bore crossings.
ENGINEERING OTHER
Restore landscape to like or better conditions.
Call for required inspections as noted.
ESC REQ
Maintain erosion and sedimentation control per City and SWMMW standard requirements.
Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to
indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and
agents from any and all claims for damages of whatever nature, arising directly or indirectly from the
HOLD HARMLESS
issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any
requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance
provision.
Concrete sidewalk shall meet the City's requirement - 3000 psi commercial mix per WSDOT 6-02.3(2)B
(see standard detail TR-531). If mix that PUD proposes to use is not installed properly or there are
OTHER CONDITION
issues with it setting after installation, PUD will be responsible for replacing any panel(s) that do not
meet City standards.
Sound/Noise originating from temporary construction sites as a result of construction activity are
exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:OOam to 6:OOpm on
SOUND OR NOISE
weekdays and 10:OOam and 6:OOpm on Saturdays, excluding Sundays and Federal Holidays. At all
other times the noise originating from construction sites/activities must comply with the noise limits
of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120.
All utilities shall be located prior to any excavation. New locates shall be called for if at time of
UTILITY LOCATES
excavation, original locates are no longer identifiable.
Is
INSPECTION TYPE
DATE
RESULT
NOTES
T 11
COMPLETE
A-1 JOB START
X-2 ENGINEERING FINAL"
E-7 TRAFFIC CTRL
E-7 CONCRETE SIDEWALK
Printed: Tuesday, May 25, 2021 11:36:16 AM 2 of 2
of EpM04O� 100034595
RIGHT OF WAY CONSTRUCTION ENG2021-0182
PERMIT APPLICATION
Complete and submit this Application in accordance with the Submittal RECEIVED
'1 r. is') Requirements outlined in Right -of -Way permit Handout E6�. MAY 19 2021
If any field is not applicable to your project, write "N/A' instead of leaving blank.
All fields required. Incomplete Applications will be denied.
CITY OF EDMONDS
DEVELOPMENT
SERVICES DEPARTMENT
SECTION A
General •
Project Name Dayton Street Utility Replacement Project - 5th Sidewalk
Site Address or if no site address use Property Address at NW corner of project area: 117 5th Ave S, Edmonds
Associated Permits: BLD PLN ENG
Owner and Entity Holding
Name of Company Snohomish County PUD (same as below) Franchise Ordinance No:
Point of Contact
Title
Address
City
State
Zip
Phone
Email
Contractor and Authorized Agent of Owner (see note below)
Name of Company Snohomish County PUD
Contractor Contacts During Construction
Primary Name Curt Christensen
Agent Name Beth Haskin
Title Restoration Crew Lead
Title Joint Use and Permit Administrator
Mobile 425-783-568o
Address PO Box 1107
Email CDChristensen@snopud.com
City Everett
State WA
Zip 98201
Secondary Name
Phone 425-783-4315
Title
Email JointUse@snopud.com BAHaskin@snopud.com
Mobile
City of Edmonds Business License No:
Email
State License No:
pJ Contractor verifies it is currently bonded
® Contractor verifies it currently has general liability insurance
NOTE: ECDC 18.6o. o2o requires that the Application be signed by a licensed and bonded contractor unless otherwise approved by the city
engineer.
❑ Multifamily residential ❑ Commercial 2g City project
❑ Single family residential subdivision ❑ Single family -other ❑ Industrial
❑ Demo and rebuild or from vacant land?
❑ Other, please specify:
❑ Utility Franchise Work associated with development (check one of the above boxes as welt
® Traffic Control Only (no associated development)
❑ Utility Franchise Work (no associated development)
City of Edmonds ROW construction permit Application --Page 1 of 3 Updated 3/25/2021
Include an overall narrative description of the proposed work. Be specific and detailed:
Describe infrastructure to be impacted, such as, poles, wires, conduit, utility mains, etc.
Include whether this is construction, maintenance, or repair.
Include description of proposed construction methods, (e.g., bores, trenches, overhead wires proposed, depth for
underground utilities, etc.)
Repair the sidewalk in front of 117 5th Ave S, Edmonds. Utility transformer lid was replaced but concrete sidewalk restoration needs to be
completed. The east sidewalk of 5th Ave S between Main St and Dayton St will need to be closed during work and sidewalk detours will be
provided at Main & 5th and Dayton & 5th.
RIGHT-OF-WAY
CLOSURE
AREA
TOTAL
DURATION
(Number of Months)
Sidewalk 72 hours +
LF
I x
LF
SF
Alley 72 hours +
LF
Ix
I LF
SF
Parking 72 hours +
LF
Ix
I LF
SF
SECTION B - If you are not a utility company performing work in the City ROW, skip to SECTION C.
1. The work in the right of way is on or for the following type of facilities:
❑ telecommunications ❑ cable ® power ❑ gas
❑ water ❑ sewer ❑ storm
Details of Work to be Completed
1. Does the utility owner have existing overhead infrastructure in the area of work?
Yes
No
X
2. Will any equipment be added underground or above ground (e.. pedestals, vaults, etc.)?
X
If yes, describe:
3.
Does the proposed work connect a lot or commercial development with utilities that serve more
than one lot or commercial development?
X
4.
Does the work involve rebuilding or relocating an existing aboveground utility system which
connects a lot or commercial development to an existing underground common utility stem?
X
5.
Does the work involve proposed additions to an aboveground utility stem? If es:
X
Are the additions for the purpose of serving new commercial development?
Are the additions for the purpose of serving a single-family residential subdivision?
Details
of Work to be Completed
Yes
No
6.
Does your project involve rebuilding or replacing utility equipment which currently serves more
than one lot or commercial development?
X
If yes, answer the following questions related to project area, i.e. the actual area in which the
project is proposed:
6a.
Does your project involve wires/cables/lines? If yes:
X
How many are existing? I I How many are to be added?
City of Edmonds ROW construction permit Application --Page 2 of 3 Updated 3/25/2021
6b.
Does your project involve poles? If yes:
X
How many poles are existing in the project area?
What is the height of the existing poles?
How many poles are to be removed?
Are additional poles to be laced?
How many? I I What is the height of the additionalpoles?
6c.
Are any poles to be modified/rebuilt/replaced? If yes:
X
How many? I I What is the height of the poles after?
Describe the modification rebuild:
SECTION C
Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as
required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have
certification verifying completion of the required training in their possession.
Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be
patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS.
Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to
any permit approval.
Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials,
officers, employees, and agents against any injuries, damages, or claims of any kind or description whatsoever,
foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectly from any act or
omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose
acts or omissions they may be liable, arising out of, related to, or by reason of the granting of this permit; and
specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any
respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the
expiration, revocation, or termination of any resulting permit approval.
Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and
requirements set forth in this Application and agrees they apply to any resulting permit and shall comply with them to
the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal
Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable
requirements of state and federal law.
Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a
licensed and bonded contractor; the information provided herein is correct and complete; and I am authorized by
owner to act on its behalf and have authority to bind the owner to this application.
Fees. The Applicant is responsible for all permit fees.
APPLICANT SIGNATURE: Ka.&"' DATE: 5/19/2021
APPLICANT PRINTED NAME: Kallen Shaug nessy- ndall
APPLICANT TITLE: Engineer
NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE
City of Edmonds ROW construction permit Application --Page 3 of 3 Updated 3/25/2021
Concrete sidewalk shall meet
the City's requirement - 3000
psi commercial mix per WSDOT
6-02.3(2)B (see attached SIDEWALK
standard detail TR-531). If mix (PEDESTRIAN
that PUD proposes to use is not
installed properly or there are
issues with it setting after
installation, PUD will be
responsible for replacing any
panel(s) that do not meet City
standards.
Main St
ENGINEERING DIVISION
APPROVED AS NOTED
05/25/2021
Dayton St
Applicant shall repair/replace all
damage to utilities or frontage
improvements in City right-of-way
per city standards that is caused or
occurs during the permitted project.
(n
Q)
Q
CLOSURE
DETOUR)
RECEIVED
MAY 19 2021
CITY OF EDMONDS
DEVELOPMENT
SERVICES DEPARTMENT
HAVE BARRICADES
NOT ENTIRELY
BLOCK SIDEWALK
SO ACCESS TO
BUSINESSES ON
EITHER SIDE OF
JOB SITE CAN
REMAIN OPEN.
SIDEWALK CLOSED
SP-6
USE OTHER SIDE
SIDEWALK CLOSED
AHEAD - CROSS HERE.
BARRICADE, TYP
SIDEWALK
CLOSED
SUIDWALK CLOSED
SP-5
SIDEWALK CLOSED
AHEAD - CROSS HERE.
OWNER/CONTRACTOR IS RESPONSIBLE FOR
EROSION CONTROL AND DRAINAGE
w P
Concrete sidewalk shall meet the City's requirement - 3000 psi commercial
mix per WSDOT 6-02.3(2)B (see attached standard detail TR-531). If mix
that PUD proposes to use is not installed properly or there are issues with
it setting after installation, PUD will be responsible for replacing any
panel(s) that do not meet City standards.
RECEIVED
MAY 19 2021
CITY OF EDMONDS
DEVELOPMENT
SERVICES DEPARTMENT
1/2" FULL DEPTH 10'
EXPANSION
JOINT DUMMY
JOINT
d a v
a d d d a v
d a
a � d
a
a a d a a
10' O.C. 5' O.C.
PLAN VIEW
(NOT TO SCALE)
1'
5' MIN MIN.
2% MAX
FULL DEPTH 1/2" EXPANSION
CURB/GUTTER SEE COE STD JOINT MATERIAL
?1i
DTL TR-520 2% MAX
a ?�M
a 1 /.2„ R d
v
a a a as as ao as as as aa�J
a
2" MIN 5/8" MINUS CSTC ON SEE NOTES 4 & 5
NATIVE SUBGRADE BEARING SOIL
SEE NOTE 9
SECTION VIEW
NOTES: (NOT TO SCALE)
1 /8" TO 1 /4"
1. CITY INSPECTION REQUIRED ON FORM WORK PRIOR TO POUR.
2. CONCRETE SHALL BE CLASS 3000/COMMERCIAL MIX. o a l 1/2"
3. FINISH SHALL BE LIGHT BROOM.
DUMMY JOINT
4. SIDEWALK THICKNESS SHALL BE 4". (NOT TO SCALE)
5. SIDEWALK THICKNESS AT DRIVEWAYS AND DRIVEWAY TRANSITIONS SHALL BE 6".
6. CURB AND GUTTER SHALL BE POURED SEPARATELY FROM SIDEWALK.
7. LIDS FOR JUNCTION BOXES AND UTILITY VAULTS SHALL BE NON—SKID AS SPECIFIED BY ENGINEER.
8. SEE COE STD DTL TR-550 FOR POSSIBLE ROOT BARRIER INSTALLATION.
9. NATIVE SUBGRADE BEARING SOIL AND CSTC SHALL BE COMPACTED TO 95% MAXIMUM DENSITY.
10. ALL EDGES AND JOINTS SHALL HAVE 1/2" RADIUS
REVISION DATE
CITY OF EDMONDS APRIL 2021
CONCRETE SIDEWALK
PUBLIC WORKS STANDARD
DEPARTMENT DETAIL
FS t . 18 9� APPROVED BY: R. ENGLISH T R — 5 31