APPROVED BLD-BLD2021-0367+Building_Floor_Plan+3.12.2021_11.34.21_AM+2090044r nay
APPROVAL STAMP PAGE
PLEASE KEEP WITH THE PLANS
PERMITTING & DEVELOPMENT
BUILDING DIVISION
121 5th Avenue N P: 425.771.0220 City Of Edmonds
www.edmondswa.gov
Building Department
----------------------------
Work AFH COMPLIANCE
-----------------------------------
Address 19615 88TH AVE W
----------------------------------------
Owner ACE SENIOR CARE HOME
Approved Date 04/19/2021
Building Official / relp�ft 91001fr4la
Permit Number
Approved by Fire
04/08/2021 AFM r'—F tterer
APPROVED
PLANS MUST BE
ON JOB SITE
-----------------
BLD2021-0367
City of Edmonds
Building Department
APPROVED Plans
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
RECEIVED
Mar 25 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
NOTE- This Stamp page must remain with the city approved plans at all times. Failure to have this
Stamp page with the City approved plans could result in delay of the inspections including the FINAL
inspection. If lost please contact the city as soon as possible to find a solution. Thank You.
35" SILL HEIGHT
EGRESS WI NDOW
35" SILL HEIGHT
It appears the upper loor
bedrooms are not de 3ignated
correctly. These bedrooms
use stairs as egress, which
would change the dE,signation
to S
NS1
11'11" X 9'8"
z8' CEILING HEIGHT
HVV Q
GARAGE
EMERGENCY ESCAPE AND RESCUE OPENINGS
SHALL BE INSTALLED IN SLEEPING ROOMS;
OPENABLE W/O USE OF KEYS, TOOLS, OR SPECIAL
KNOWLEDGE. IRC R310
* MIN. 5.7 SF NET CLR OPENABLE AREA
* MIN. 24" NET CLR OPENABLE HEIGHT
* MIN. 20" NET CLR OPENABLE WIDTH
* MAX. 44" FINISHED SILL HEIGHT
ALL BEDROOM WINDOWS IDENTIFIED AS EGRESS
DRIVEWAY
EGRESS WINDOW
BEDROOM B
NS1
130" X 130"
8' CEILING HEIGHT
BATHROOM
no
. ■ 0001l 1
DRIVEWAY
1
C
EGRESS WINDOW
BEDROOM C
NS1
172" X 119"
8' CEILING HEIGHT
� uu
°
o KITCHEN
°
Ln
1ST FLOOR PLAN
FURNACE
❑ \/7
BEDROOM A
NS1
180" X 156"
8' CEILING HEIGHT
EGRESS WINDOW
35" SILL HEIGHT
L71�1��1�
DO
BATHROOM
(E)
(E)
0
KI I C:HLN
BEDROOM E
NS1
11'11" X 9'8"
8' CEILING HEIGHT
0
LIVING ROOM
9' CEILING HEIGHT
EGRESS WI NDOW
35" STILL HEIGHT
:01
EGRESS WINDOW
O' \ ' 35" SILL HEIGHT
H
W
EGRESS DOOR
Windows designated
as egress, and
installed under a deck
or porch, must meet
the requirements of
' 2018 1 RC Section
310.2.4 Emergency
and rescue openings
under decks and
porches.
;All bathrooms '
servicing rooms
; designated as
; bedrooms for '
clients, must have
grab bars installed
in accordance with '
2018 International
; Residential Code
Section 330.8. '
� Carbon Monoxide alarms
w
= M
-are required for this home
n
per 2018 IRC Section 315.
r �
The alarms shall be placed i
m z
in locations as described
0
in 2018 IRC Section 315.3. ■
(Combination alarms are
acceptable.
LIVING ROOM
I' CEILING HEIGHT
1
EGRESS WINDOW
35" SILL HEIGHT
only the common bathroom on
the 2nd floor has grab bars.
0 THERMOSTAT
FIRE DISTINGUISHER
/—� HARDWIRED & INTERCONNECTED SMOKE
\—/ DETECTORS WITH BATTERY BACKUP
BLD2021-0367
RECEIVED
Mar 25 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
2ND FLOOR PLAN