Loading...
APPROVED BLD-BLD2021-0367+Building_Floor_Plan+3.12.2021_11.34.21_AM+2090044r nay APPROVAL STAMP PAGE PLEASE KEEP WITH THE PLANS PERMITTING & DEVELOPMENT BUILDING DIVISION 121 5th Avenue N P: 425.771.0220 City Of Edmonds www.edmondswa.gov Building Department ---------------------------- Work AFH COMPLIANCE ----------------------------------- Address 19615 88TH AVE W ---------------------------------------- Owner ACE SENIOR CARE HOME Approved Date 04/19/2021 Building Official / relp�ft 91001fr4la Permit Number Approved by Fire 04/08/2021 AFM r'—F tterer APPROVED PLANS MUST BE ON JOB SITE ----------------- BLD2021-0367 City of Edmonds Building Department APPROVED Plans ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE RECEIVED Mar 25 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT NOTE- This Stamp page must remain with the city approved plans at all times. Failure to have this Stamp page with the City approved plans could result in delay of the inspections including the FINAL inspection. If lost please contact the city as soon as possible to find a solution. Thank You. 35" SILL HEIGHT EGRESS WI NDOW 35" SILL HEIGHT It appears the upper loor bedrooms are not de 3ignated correctly. These bedrooms use stairs as egress, which would change the dE,signation to S NS1 11'11" X 9'8" z8' CEILING HEIGHT HVV Q GARAGE EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE INSTALLED IN SLEEPING ROOMS; OPENABLE W/O USE OF KEYS, TOOLS, OR SPECIAL KNOWLEDGE. IRC R310 * MIN. 5.7 SF NET CLR OPENABLE AREA * MIN. 24" NET CLR OPENABLE HEIGHT * MIN. 20" NET CLR OPENABLE WIDTH * MAX. 44" FINISHED SILL HEIGHT ALL BEDROOM WINDOWS IDENTIFIED AS EGRESS DRIVEWAY EGRESS WINDOW BEDROOM B NS1 130" X 130" 8' CEILING HEIGHT BATHROOM no . ■ 0001l 1 DRIVEWAY 1 C EGRESS WINDOW BEDROOM C NS1 172" X 119" 8' CEILING HEIGHT � uu ° o KITCHEN ° Ln 1ST FLOOR PLAN FURNACE ❑ \/7 BEDROOM A NS1 180" X 156" 8' CEILING HEIGHT EGRESS WINDOW 35" SILL HEIGHT L71�1��1� DO BATHROOM (E) (E) 0 KI I C:HLN BEDROOM E NS1 11'11" X 9'8" 8' CEILING HEIGHT 0 LIVING ROOM 9' CEILING HEIGHT EGRESS WI NDOW 35" STILL HEIGHT :01 EGRESS WINDOW O' \ ' 35" SILL HEIGHT H W EGRESS DOOR Windows designated as egress, and installed under a deck or porch, must meet the requirements of ' 2018 1 RC Section 310.2.4 Emergency and rescue openings under decks and porches. ;All bathrooms ' servicing rooms ; designated as ; bedrooms for ' clients, must have grab bars installed in accordance with ' 2018 International ; Residential Code Section 330.8. ' � Carbon Monoxide alarms w = M -are required for this home n per 2018 IRC Section 315. r � The alarms shall be placed i m z in locations as described 0 in 2018 IRC Section 315.3. ■ (Combination alarms are acceptable. LIVING ROOM I' CEILING HEIGHT 1 EGRESS WINDOW 35" SILL HEIGHT only the common bathroom on the 2nd floor has grab bars. 0 THERMOSTAT FIRE DISTINGUISHER /—� HARDWIRED & INTERCONNECTED SMOKE \—/ DETECTORS WITH BATTERY BACKUP BLD2021-0367 RECEIVED Mar 25 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 2ND FLOOR PLAN