APPROVED 19-014 Purser LOT 2 Civil Plans 2020-06-05LEGAL DESCRIPTION
LOT 11 OF BEL-AIRE DIVISION B, ACCORDING TO THE PLAT RECORDED IN VOLUME 20 OF
PLATS AT PAGE 44, IN SNOHOMISH COUNTY, WASHING TON;
SITUATE IN THE COUNTY OF SNOHOMISH, STATE OF WASHIN GTON.
HORIZONTAL DATUM
NAD 8312011
VERTICAL DATUM
NA VD 88
W*AY- #1;kk I:I:1
SNOHOMISH COUNTY BENCHMARK NO. SC32
FOUND CONCRETE MONUMENT IN CASE W/ 2" BRASS DISC W/ PUNCH AT THE
INTERSECTION OF 220TH STREET SW AND 92ND AVENUE W.
ELEVATION = 411.22'
SNOHOMISH COUNTY BENCHMARK NO. SC 33
FOUND CONCRETE MONUMENT IN CASE W/ 2" BRASS DISC W/ PUNCH ON THE
CENTERLINE OF 100TH AVENUE W. AT THE SOUTHEASTERLY CORNER OF EDMONDS
MEMORIAL CEMETERY.
ELEVATION = 312.05'
LOT COVERAGE
LOT AREA: 8,538 SF
ALLOWABLE COVERAGE (3590) 2,988 SF
HOUSE, COVERED DECK & GARAGE 2,232 SF
PERCENT COVERAGE 26.14%
BUILDING HEIGHT
CALCULATIONS (AOG)
SPOT ELEVA TIONS FOR HEIGHT CALCULA TONS.•
ELEVA TION A:
286.78
ELEVA TION B:
286.79
ELEVA TION C:
286.42
ELEVA TION D:
286.80
TO TA L: =
1146.79
A VERAGE ORIGINAL GRADE (AOG) =
286.70
FINISHED FLOOR =
288.00
ROOF AT RIDGE =
310.83
ALLOWABLE BUILDING HEIGHT =
311.70
PER CITY OF EDMONDS
(286.70 + 25 FT)
IMPERVIOUS AREAS -LOT 2
HOUSE+COVERED D/W, PATIO, PORCH, WALK 2,535 SF
(ROOF LINE)
UNCOVERED PA TIO AND WALK 100 SF
UNCOVERED DRI VEWA Y 1.065 SF
LOT 2 TOTAL = 3, 700 SF
GRADING QUANTITIES
CUT f100 CU YDS
FILL: t 100 CU YDS
1) GRADING QUANTITIES INCLUDE ADDITIONAL CUT AND FILL QUANTITIES POTENTIALLY NEEDED FOR
ORGANIC SOIL AMENDMENTS IN ACCORDANCE WITH BMP T5.13 POST CONSTRUCTION SOILS
QUALITY AND DEPTH.
2) GRADING QUANTITIES HAVE BEEN ESTIMATED AS SHOWN ABOVE. SITE IMPORT AND EXPORT IS
BELOW 10,000 CY AND THUS NO HAUL ROUTE AGREEMENT IS REQUIRED.
NOTES
A. A SEPARATE RIGHT—OF—WAY CONSTRUCTION PERMIT IS REQUIRED FOR ALL
WORK WI THIN THE CI TY RIGHT —OF— WA Y.
B. THE APPROVAL OF THESE PLANS DOES NOT INCLUDE APPROVAL OF THE
SINGLE FAMILY RESIDENTIAL CONSTRUCTION.
UTILITY NOTE
ALL NEW UTILITIES ARE REQUIRED TO BE INSTALLED UNDERGROUND.
CONSTRUCTION NOTE
4PPLICANT SHALL REPAIR/RELACE ALL DAMAGE TO UTILITIES OR FRONTAGE
MPR0VEMEN IS IN Cl TY RIGHT —OF— WA Y PER CI TY STANDARDS THA T IS CAUSED
)R OCCURS DURING THE PERMITTED PROJECT.
STORMWATER CONTROL SUMMARY
PROJECT S17E CA TEGOR Y CA 7EGOR Y 2
DISCHARGE LOCATION: CI TY'S MUNICIPAL SEPARATE STORM SEWER SYSTEM (MS4)
SW1/4, SEC 31, TWP 27N, RGE 4E, W.M.
PURSER SHORT PLAT -LOT 2
SITE DEVELOPMENT PLAN
I0
=
SHORT PLAT IMPROVEMENTS N cn
CONSTRUCTED AS PART OF BREGANTE CARLOS
THE PURSER SHORT PLAT 1427 7th PL S, EDMONDS, I I I ® I J— SS �4 TH WAYS W
(PLN29190040) WA 98020 I
PARCEL NO.
15' ACCESS AND 00390000001200
UTILITY EASEMENT
i FOR THE BENEFIT
OF LOTS 1 & 2.
, ' \�� N32 25'53 E I I tl I101
I I
oNP �$' / / i -_/--
-- \�\� _-- -- - 15.14'
/ .ti /�j � �� /
N65 2126 "W 1 / I (Z =1
14 8�t'-_ ��/��o ---1- 286- �) I % �� w I II11 I
DRY UTILITIES I I I N II I I I I BALLARD DONALD & JULIANNE
i / 1 - CONNECT TO 1435 8th AVE S, EDMONDS, WA
CONCRETE STORM STUB`-, I I 1 0 III 1
DRl VEWA Y 0� o I 98020
, 4" PVC / I ji
�I 11' I I PARCEL N0. 00393100000400
/� ROOF DRAIN ��� I j I 1 / I �'� 0
0, GARAGE \ 1.09 MINN%�\`/ I I
FF 286.50SDCO \ t BSBL I 131 /
4f PVC FOOTING / �`�� ,p / IE 284. I TYP a I 1
DRA @ 1.07 MINLci
110' MIN LENGTH FOOTINGS -
°y0 �� \ DRAIN DRYWELL ,TRENCH / PROPOSED HOUSE C � o 31 G-—
GEOTECH '�l I "�j
RECOMMENDA T10146) COVERED MAIN FF 288.00
M/N i 2
_ \ c \ I a�,,, < gSAy \ 8, 538 SF
I gspy is ,,2 �% O�Yy SSCO / 20' i 3(g1 • �� 1
IE 85.0fOX-
30 I
6'
4" PVC SEWER
SERVICE ®2.09 ?94--`\ I I i I ��\ i I I BARTH DANIEL
WILSON SHOWN & PETERSON LINDSAY \ '�'0 �\ I 0 gyp. CONNEC III 11439 8th AVE S, EDMONDS,
20
728 15th ST SW, EDMONDS, WA \ \ �\ i �RR2 \� ` SEWER STUB ro \�1II I I PARCELWA NO.
98020 \ \ \ II ,288-' \ \ lE 83.0E i / I I I I I I 00393100000300
PARCEL NO. 00390000000200
�
1I I d=21 33 23"
1" WATER SERVICE INSTALL AS �� j � \ / R=25.00'
PART OF SHORT PLAT. \ ,�\ I g L=53.04' I III 1 1
INSTALL 1 " WATER METER AND \ .' J2 \ \ _ / /3
1-1/2" PE (160 PSI) SERVICE LINE \ •� — —, 1 1 I
FROM WATER METER TO HOUSE
DETAILS. (TRACER WIRE TO BE \ dy0 \ I �'S I II I I I
INSTALLED WITH WATER LINE) S\
\ d I \ ,1(18838,i4.W I I III I I
73' (68 76' PLA T)
I
—SD—__
— SD
/ IBM A �\ / ► 0\ — �� I_ S\ I FOUND CONCRETE MONUMENT
FOUND CONCRETE MONUMENT \ ` / / l , \ I i I i IN CASE W/ 2- BRASS DOME
TYPE OF
AREA
SQUARE
FOOTAGE
STORMWA TER
FACILI TY
LA WN AND LANDSCAPE
4, 838 SF
SOIL AMENDMENTS (BMP T5.13
ROOFS
2, 535 SF
INFILTRATION TRENCH MEETING LID PERFORMANCE STD
HARD SURFACES
1,165 SF
INFIL IRA TION TRENCH MEETING LID PERFORMANCE STU
259. RETROFIT
0 SF
N.A.
SCHAFFER COLLEEN & //
MICHAEL SS
727 15th ST SW, EDMONDS, /
WA 98020
PARCEL NO.
00390000001000
IN CASE W/2" BRASS DOME i W/ PUNCH
W/ PUNCH DOWN 0.6' _i // / i/7- �S`S► Nor— DOWN 1. 1'
SVENSSON STEFFY CYNTHIA TOP BRASS DOME EL 292.05
COTT
1502th PLF S S, EDMONDS,——
WA 98020
PARCEL NO.
00745J00000100 / / dyo
SHAW ADRIAN C \ T
740 15th ST SW, EDMONDS, I
WA 98020 �
PARCEL NO.
/ 00390000000100
WAL UT T
NCEDAR ST
rn
Q h PINE ST
2 2 e
_ U N
BELLA COOLA RD ST
Q 220 S SW
to
_ 224 S S
PUGET
SOUND 226TH
ST S
S,T 228TH T S
S DEER D 3
Q 2 N T SW
— — WACHUSETT RD
ST SW
VICINITY MAP
NOT TO SCALE
SCALE. 1" = 20'
0 10 20 40
PROJECT TEAM
APPLICANT
PURSER DEVELOPMENT SERVICES, LLC
520 3RD AVE N
EDMONDS, WA 98020
(425) 531- 0923
CONTACT. ROB PURSER
CIVIL ENGINEER
!kl; Aq_1TJi
NORTH PEAK ASSOCIATES, LLC
17270 WOODINVILLE REDMOND ROAD NE, STE 705
WOODINVILLE, WA 98072
(206) 601-4682
CONTACT STEVEN C. BERG, PLS
GEOTECHNICAL
RAM ENGINEERING, INC.
EARTH SOLUTIONS NW, LLC
16531 13TH AVE W, SUITE A 108
1805 136 TH PL NE, SUITE 201
L YNNWOOD, WA 98037
BELLEVUE, WA 98005
(425) 678-6960
PHONE: (425) 449-4704
CONTACT: ROB L. LONG, PE
CONTACT: HENRY WRIGHT, PE
EMAIL: ROBL@RAMENGINEERINGINC.COM EMAIL: HENRYWOESNW.COM
SITE DATA
SITE ADDRESS.
735 15TH ST. SW EDMONDS, WA 98020
TAX PARCEL ID NUMBER:
00390000001100
TOTAL SITE AREA:
XXXXX SF (0. XX AC)
EXISTING ZONING:
RS-6 (6,000 SF)
PROPOSED LAND USE:
SINGLE FAMILY RESIDENTIAL
MAX BUILDING HEIGHT:
25 FEET
MAX LOT COVERAGE FOR STRUCTURES. 359 TOTAL LOT AREA
AGENCIES/UTILITIES
JURISDICTION
CITY OF EDMONDS
STORM WATER
CITY OF EDMONDS
WATER DISTRICT
OLYMPIC VIEW WATER & SEWER DISTRICT
SEWER DISTRICT
CITY OF EDMONDS
SCHOOL DISTRICT
EDMONDS SCHOOL DISTRICT NO. 15
FIRE DISTRICT
SNOHOMISH COUNTY FIRE DISTRICT NO. 1
TELEPHONE
FRONTIER COMMUNICATIONS
ELECTRICAL
SNOHOMISH COUNTY PUD NO. 1
GAS
PSE
CABLE
COMCAST
SHEET INDEX
1 SP-01 SITE DEVELOPMENT PLAN
2 TP-01 CLEARING, GRADING & TESC PLAN
3 GN-01 GENERAL NOTES & DETAILS
•
Know what's below.
Call before you dig.
BLD2020-0378
APPROVED FOR CONSTRUCTION
CITY OF EDMONDS
DATE:
BY
CITY ENGINEERING DIVISION
RAMI
ENGINEERING, INC.
Civil Engineering / Land Planning
16531 13TH AVE W, SUITE A108
LYNNWOOD, WA 98037
PHONE: (425) 678-6960
WWW.RAMENGINEERINGINC.COM
0
Z
Z
CA
2 Q
go WAg�V l�
d
�' aeeoa w
�EGISTER�9
T .�/
ENGINEER:
16/5/zo
ROB L. LONG, PE
DRA WN BY.•
MIKE MORRIS
ISSUE DATE: SCALE.•
3/4/20 AS NOTED
JOB NO:
19-014
SHEET
SP-0 1
SH T / OF 3
It
l j ill l #
/till
/
/ l % Pp l L
BJ
D/11
FFILTER
ENCE FAI
O 285
FG
\ c`y
CB TYPE 2
RIM=280.24 / j i , l / 12'F47 Ul/T
12'7E(NE) RCP= 274.8 / ONP 2�� / / �' �� 7 - J \ \ \`- --- --
127E(SE) RCP= 275.0 i / of ' / A\ �\\
12 9E(SW) RCP=�
ffEiT .0
8IV
�,' / / ' v7 / 1 286.
Z a 26
010 SF / f FG // / CONCRDTi
�V\ 6"F IT / / / DRI VEW a,I
1 / G� ORAN I/E BARRIER \ /
FENCING tE PLACED \ / / GARAG
FENCI �
/ I \ % / AROND IN F N TRENCH / / FF 286.50
AFTi? INSTALLA A ENCE TO /
\ BE IEMO VED %CFG
O N OF / / 286.5
CB TYPE SOLID LID _ HOU E CONST4lY TION. / \
RIM=278.41 - �.SS
s lE(S)=27Z _S / / \ �� \ /
\ \ \ ��ti \ I / �\ \ / / i PROPO�SEQ HpUSE
`� \ i COVERED MAIN FF 288.00
\ \ �\ \S,S \ \ »CON `�\ PATIO
_ $
CB TYPE SOLID LID i / \
RIM=279.00 i\ ��-- 1 \ \ `�
6'7E(N&E)=277.0 SSMH
RIM=280.77
811E(IN SW, E.)(OUT N.) PVC 86' EXISTING TREE TO
CTR. CHAN.=273 E. 4 RIM \\ \ ` �\ --2 \ BE REMOVED
I4FCH /
DEC
290 �SS �
EXISTING
FIRE \
HYDRANT \ ayp \ I
1
1
\ , ss�
�. 11
2" x 2" WOOD/STEEL
FILTER FABRIC SECURED
TO 2" x 2" 14 GA
WIRE FABRIC EQUAL
0
N
NATIVE BACKFILL MATERIAL
FILTER FABRIC MATERIAL IN CONTINOUS ROLLS
USE STAPLES OR WIRE RINGS TO ATTACH
FABRIC TO WIRE
2" x 2" WOOD/STEEL POSTS -\
I�
ivPPORT FILTER
FABRIC
1I BURY BOTTOM OF FILTER
a MATERIAL 8" TO 12"
NOTES:
1. CONTRACTOR/DEVELOPER SHALL MAINTAIN AND ENSURE PROPER
EROSION CONTROL THROUGHOUT PROJECT.
2. SILT FENCE TO BE PLACED DOWNSLOPE OF CONSTRUCTION
ACTIVITY.
`St. 1B9-
CITY INSPECTION REQUIRED ON
ALL EROSION CONTROL METHODS
BEFORE OTHER WORK CAN BEGIN
REVISION DATE
CITY OF EDMONDS FILTER FABRIC FENCE AUGUST 2017
FILTRATION SYSTEMS
PUBLIC WORKS STANDARD
DEPARTMENT DETAIL
APPROVED BY: R. ENGLISH E R - 9 00
CITY OF EDMONDS
PUBLIC WORKS
DEPARTMENT
CATCH BASIN
SW1/4, SEC 31, TWP 27N, RGE 4E, W.M.
_;MH
RIM=289.57 - - - _
87E(IN E.) (OU N.) PVC iPP CB TYPE 1
C7R. CHAN.=2 0.1 E.RIM \ -
I i RIM=288.48
127E(N) RCP=283.4
I 12%E(S) RCP=283.5
14TH WA Y SW
I I �
T12 I CB TYPE
I I RIM=289.60
A/RE I / / I \ 8%E(N) RCP=287.7
9/ON B
Oy PG. 44 I o
c I III I \lil I /
I o 1 II II 11 I /�
284.8 N III IIII
TOP CB CLEARINL A417S (G) I III Ila- l I
I
FNWA
R O7Ec77 NG AS V I I IIII I
/ 286. III 11= I I I
.286---1 �� I IIII
286.01 1 42 "FIR
I �I IIII I
iI ,, _,\ it I i
r
�� =1 I
0
11 I
111
/ �\ I ► ; III I 11 I I
► Ia.
IoI I
/ I 4"MAD
/ I ► I I III I
/ I ►' III, I IIII I I----
// I ► III 1=
►
/ C
W I I
o f I 10
;`�9� FIR III Q ' ► 1
� �o,��,
2
/ I '
` � 0 �,R ,-294-
- I Op IIII
"FIR,
I 0' \�`II
V
II
i I l II i I I I CB TYPE 1
RIM 295.22
_ 7-0 i /j3 I II I I I I 127E(N) RCP=290.2
c� 127E(S) RCP=291.4
---Go �a% "i I I I 127E(E) RCP=290.4
' I
IIII
PROPOSED CB
PR07EC77ON (TYP)
Sp - - -
NN
1\ `
7/yn
FILTER SOCK WITH
OVER FLOW HOLES
(n'P)
NOTES:
1. CONTRACTOR/DEVELOPER SHALL MAINTAIN
THIS APPLICATION AT ALL TIMES DURING
CONSTRUCTION PERIOD.
2. ANY SEDIMENT IN CATCH BASIN INSERT
SHALL BE REMOVED WHEN INSERT IS
ONE-THIRD FULL.
3. CITY INSPECTION REQUIRED ON ALL
EROSION CONTROL METHODS BEFORE
OTHER WORK CAN BEGIN.
TEMPORARY
SEDIMENT TRAP
FOR CATCH BASINS
APPROVED BY: R. ENGLISH
REVISION DATE
AUGUST 2017
STANDARD
DETAIL
ER-902
TREE PROTECTION NOTES
1. ANY WORK INSIDE THE DRIP LINES OF EXISTING TREES MUST TAKE PLACE IN ACCORDANCE
WITH ECDC 18.45.050.H SUBSECTIONS (1) - (6).
2. DURING CONSTRUCTION ADDITIONAL TREES MAY NEED TO BE REMOVED DUE TO IMPACTS
FROM THE PROPOSED SITE DEVELOPMENT. AN ARBORIST SHALL EVALUATE TREES PRIOR TO
REMOVAL AND CITY SHALL APPROVE ANY ADDITIONAL TREE REMOVAL.
3. PROTECTIVE BARRIER. BEFORE DEVELOPMENT, LAND CLEARING, FILLING OR ANY LAND
ALTERATION, THE APPLICANT SHALL:
a. ERECT AND MAINTAIN READILY VISIBLE TEMPORARY PROTECTIVE TREE FENCING ALONG
THE LIMITS OF DISTURBANCE TO COMPLETELY SURROUND THE PROTECTED AREA OF ALL
RETAINED TREES OR GROUPS OF TREES. FENCES SHOULD BE CONSTRUCTED OF
CHAIN -LINK AND BE AT LEAST SIX (6) FEET HIGH, UNLESS OTHER TYPE OF FENCING IS
AUTHORIZED BY THE CITY.
b. WHEN REQUESTED BY THE CITY, INSTALL HIGHLY VISIBLE SIGNS SPACED NO FURTHER
THAN 15 FEET ALONG THE ENTIRETY OF THE PROTECTIVE TREE FENCE. SAID SIGN MUST
STATE AT A MINIMUM "TREE PROTECTION AREA, ENTRANCE PROHIBITED' AND PROVIDE
THE CITY PHONE NUMBER FOR CODE ENFORCEMENT TO REPORT VIOLATIONS.
c. PROHIBIT EXCAVATION OR COMPACTION OF EARTH OR OTHER POTENTIALLY DAMAGING
ACTIVITIES WITHIN THE BARRIERS; PROVIDED, THAT THE ADMINISTRATOR MAY ALLOW
SUCH ACTIVITIES APPROVED BY THE CITY TREE PROTECTION PROFESSIONAL AND UNDER
THE SUPERVISION OF A QUALIFIED TREE PROFESSIONAL RETAINED BY THE APPLICANT.
d. MAINTAIN THE PROTECTIVE BARRIERS IN PLACE FOR THE DURATION OF THE PROJECT
UNTIL THE CITY AUTHORIZES THEIR REMOVAL.
e. ENSURE THAT ANY APPROVED LANDSCAPING DONE IN THE PROTECTED ZONE
SUBSEQUENT TO THE REMOVAL OF THE BARRIERS SHALL BE ACCOMPLISHED WITH
WALK -BEHIND MACHINERY OR HAND LABOR.
f. IN ADDITION TO THE ABOVE, THE CITY MAY REQUIRE THE FOLLOWING:
i) IF EQUIPMENT IS AUTHOR/ZED TO OPERATE WITHIN THE CRITICAL ROOT ZONE, COVER
THE AREAS ADJOINING THE CRITICAL ROOT ZONE OF A TREE WITH MULCH TO A DEPTH
OF AT LEAST SIX (6) INCHES OR WITH PLYWOOD OR SIMILAR MATERIAL IN ORDER TO
PROTECT ROOTS FROM DAMAGE CAUSED BY HEAVY EQUIPMENT.
ii)MINIMIZE ROOT DAMAGE BY EXCAVATING A 2-FOOT-DEEP TRENCH, AT EDGE OF
CRITICAL ROOT ZONE, TO CLEANLY SEVER THE ROOTS OF TREES TO BE RETAINED.
Ill) CORRECTIVE PRUNING PERFORMED ON PROTECTED TREES IN ORDER TO AVOID
DAMAGE FROM MACHINERY OR BUILDING ACTIVITY.
iv) MAINTENANCE OF TREES SHALL BE ACHIEVED BY THE APPLICANT THROUGHOUT
THE CONSTRUCTION PERIOD BY WATERING AND FERTILIZING.
fil
SCALE. 1" = 20'
0 10 20 40
CONSTRUCTION SEQUENCE
1. SCHEDULE A PRE -CONSTRUCTION MEETING WITH CITY ENGINEERING DIVISION
AT MYBUILDINGPERMIT.COM. TWO DAY (48 HR) NOTICE IS REQUIRED.
2. REVIEW TEMPORARY EROSION AND SEDIMENT CONTROL NOTES.
J. CALL FOR UTILITY LOCATES.
4. INSTALL TESC MEASURES AND MAINTAIN DUST CONTROL WHILE PREVENTING
DISTURBANCE OF ANY AREAS OF VEGETATION OUTSIDE THE CONSTRUCTION
ZONE.
5. HAVE EROSION CONTROL MEASURES INSPECTED BY CITY OF EDMONDS CITY
ENGINEERING INSPECTOR. ALL TEMPORARY SEDIMENTATION AND EROSION
CONTROL MEASURES MUST BE IN PLACE AND INSPECTED PRIOR TO ANY
CONSTRUCTION OR SITE CLEARING. EROSION AND SEDIMENTATION CONTROL
PRACTICES AND/OR DEVICES SHALL BE MAINTAINED UNTIL PERMANENT
VEGETATION IS ESTABLISHED.
6. DEMOLISH EXISTING STRUCTURES (UNDER SEPARATE PERMIT).
7. ROUGH GRADE SITE AS REQUIRED TO INSTALL DRAINAGE FEATURES.
8. CLEAR, GRUB & ROUGH GRADE SITE. REVEGETATE DISTURBED AREAS NOT
SUBJECT TO ADDITIONAL SURFACE DISTURBANCE IMMEDIA TEL Y AFTER ROUGH
GRADING. (OTHER EXPOSED AREAS SHALL BE STABILIZED PER EROSION
CONTROL NOTES BELOW)
9. INSTALL UTILITIES AND OTHER SITE IMPROVEMENTS.
10. STABILIZE AND COMPOST AMEND ALL EXPOSED SOILS PRIOR TO
REVEGETA TION OF ENTIRE SI TE.
11. ESTABLISH LANDSCAPING AND PERMANENT VEGETATION. ALL TEMPORARY
EROSION CONTROL MEASURES SHALL BE REMOVED UPON FINAL SITE
STABILIZATION AND APPROVAL BY CITY INSPECTOR.
GRADING QUANTITIES
CUT FILL
f 100 CY f 100 CY
TESC NOTE
INSTALL AND MAINTAIN ALL TESC MEASURES ACCORDING
TO APPROVED PLANS, EDMONDS STANDARD DETAILS, AND
THE SWPPP. CONTRACTOR lS RESPONSIBLE FOR
MAINTENANCE AND ADJUSTWENTS TO TESC MEASURES AS
NEEDED.
CB INLET PROTECTION NOTE
CATCH BASIN INLET PROTECTION SHALL BE INSERTED AND
MAINTAINED ON ALL NEWLY CONSTRUCTED CATCH BASINS
THROUGHOUT THE SITE IMMEDIATELY AFTER INSTALLATION.
FILTER FABRIC FENCE NOTE
ADDITIONAL FILTER FABRIC FENCING SHALL BE ADDED AS
NEEDED. FENCING TO BE INSTALLED PER CITY OF EDMOND �
STD DETAIL ER-900 (SEE DETAIL ON SHEET TD-01).
STOCKPILE NOTE
STOCKPILE SHALL TO STABILIZED BY PLASTIC COVERING.
THE EXPOSED SOILS SHALL BE STABILIZED ACCORDING TO
AN APPROVED TIMETABLE. (TYPICALLY, NO SOILS SHALL
REMAIN EXPOSED FOR MORE THAN TWO DAYS FROM
OCTOBER 1 THROUGH APRIL 30 AND NO MORE THAN
SEVEN DAYS FROM MAY 1 THROUGH SEP TEMBER 30).
SOILS NOTE
ALL DISTURBED SOILS WILL BE COMPOST AMENDED PER
BMP T.5.13.
SPECIAL INSPECTION NOTE
GE07ECHNICAL APPROVAL OF 7HE INFILTRATION SUBGRADE
IS REQUIRED PRIOR TO PLACING ANY ROCK OR FABRIC
FOR THE INFILIRA 77ON TRENCH. CONTACT GE07ECHNICAL
ENGINEER BEFORE PROCEEDING WITH INSTALLATION OF THE
INFIL TRA TION TRENCH.
Option (Choose
one)
Turf (grass or lawn) Areas
Planting Bed Areas
1 - Compost -Amend
existing soils (See
1. Ensure that there is at least 6 inches (in) of existing soil in the
1. Ensure that there is at least 5 in of existing soil in the disturbed area
Figure 1 for turf and
disturbed area (if not add topsoil).
(if not add topsoil).
Figure 2 for planting
2. Place 1 1/2 to 1 3/4in of compost on top of existing soil. Till or
2. Place 3 in of compost on top of existing soil. Till or otherwise mix
beds)
otherwise mix the compost into the top 6 inches of existing soil such
the compost into the top 6 inches existing soil such that the depth
that the depth right after mixing is about 9.5 in (mixing will entrain air
right after mixing is about 9.5 in (mixing will entrain air into the
into the mixture and make it fluffy). It may be necessary to loosen
mixture make it fluffy). It may be necessary to loosen (scarify)
(scarify) existing soil to facilitate this mixing.
existing soil to facilitate this mixing.
3. Water or roll to slightly compact to the 9.5 inch compost -amended
3. Water or roll to slightly compact to the 9.5 inch compost -amended
soil layer to approximately 8 inches.
soil layer to approximately 8 inches.
4. Rake to smooth and remove surface woody debris and rocks larger
4. Rake to smooth and remove surface rocks larger than 2 inch in
than 1 inch in diameter (if any).
diameter (if any)
5. Mulch planting beds with 2 to 4 inches of organic mulch (i.e.,
For 100 square feet of turf area: A 1 1h to 1 3/4 inch lift requires -14 cubic
arborist wood chips, leaves, bark) - Recommended not required.
feet or -1/2 cubic yard of compost.
For 100 square feet of planting bed area: A 3 inch lift requires 25 cubic
feet or -I cubic yard of compost.
2 - Import
1. Place a 3 inch thick layer of a topsoiUcompost mixture that contains
1. Place a 3 inch thick layer of a topsoiUcompost mixture that contains
Topsoil/Compost Mix
4% to 5% organic matter (typically 25-35% compost by volume - the
approximately 10% organic matter (typically 40% compost by
balance shall be sand and or sandy loam soil).
volume) - the balance shall be sand and or sandy loam soil).
2. Till or otherwise mix into the top 2 inches of existing soil. It may be
2. Till or otherwise mix into the top 2 inches of existing soil. It may be
necessary to loosen (scarify) existing soil to facilitate this mixing.
necessary to loosen (scarify) existing soil to facilitate this mixing.
3. Place a second lift of 3 inches of the topsoil/compost mixture on the
3. Place a second lift of 3 inches of the topsoil/compost mixture on the
surface.
surface.
4. Water or roll to slightly compact.
4. Rake to smooth and remove surface rocks larger than 2 inch in
5. Rake to smooth and remove surface woody debris and rocks larger
diameter (if any)
than 1 inch in diameter (if any).
5. Mulch planting beds with 1 to 2 inches of organic mulch (i.e.,
leaves, bark) - Recommended not required.
For 100 square feet of turf area: each 3 inch lift will require 25 cubic feet
(-1 cubic yard) of the topsoiUcompost mix. This mix will have
For 100 square feet of planting bed area: the each 3 inch lift will require
approximately 30% compost by volume (0.3 cubic yards, - 8.1 cubic feet)
25 cubic feet (-1 cubic yard) of the topsoil/compost mix. This mix will
and 70 % topsoil by volume (0.7 cubic yards, -19 cubic feet).
have approximately 40% compost by volume (0.4 cubic yards, -11 cubic
feet) and 60 % topsoil by volume (0.6 cubic yards, -16 cubic feet).
COMPOST -AMENDED SOILS REQUIREMENT
FOR TURF AND PLANTING BED AREAS
TREE PROTECTION DETAIL
NOT TO SCALE
I
Know what's below.
Call before you dig.
BLD2020-0378
APPROVED FOR CONSTRUCTION
CITY OF EDMONDS
WE.
BY.
CITY ENGINEERING DIVISION
ENGINEERING, INC.
Civil Engineering I Land Planning
RAMI
16531 13TH AVE W, SUITE Al08
LYNNWOOD, WA 98037
PHONE: (425) 678-6960
WWW.RAMENGINEERINGINC.COM
16/5/ZO
I�irlglL�l��:�l
O
Z
ROB L. LONG, PE
DRAWN BY
MIKE MORRIS
ISSUE DATESCALE.•
314120 AS N07ED
JOB NO:
19-0114
SHEET. TP-0 1
SHT 2 OF 3
RESIDENCE
1 1 2' '
CLEANOUT (MAX)
(TYP)
w
Z
}J
F
w
a
0
CLEANOUT a
WITH 45'
BEND AND
CAP
NOT TO EXCEED 100' BETWEEN CLEANOUTS
CLEANOUT (WYE WITH CAP
AND CLEANOUT COVER) AND
CONCRETE LEVELING COLLAR
2" t f-FINISHED GRADE
WATER TIGHT CAP
45' RISER
/ 45'
4" OR 6" SIDE SEWER
GENERAL CLEANOUT DETAIL
12" LOCKING COVER
3
SEE NOTE 3
La w
z
0 w
LEVELING COLLAR
_0
N
SEE NOTE 4
a a
6
ASPHALT SURFACE
12" t
�1 FOOT LONG 12" PVC
SLEEVE
6" RISER END OF PIPE GRIPPER
PLUG (CHERNE 270261
OR APPROVED EQUAL)
TYPICAL CLEANOUT
UNDER ASPHALT OR CONCRETE
`SI. 181 -
Z
Q
Of
w
U)
r
�z
�
w
Uj
w
Uj
w
0
0
12" LOCKING COVER
3
SEE NOTE 3
w
0
END OF PIPER GRIPPER PLUG
(CHERNE 27061 OR APPROVED
a
0
EQUAL)
LEVELING COLLAR -
SEE NOTE 4
12" PVC SLEEVE -
6" RISER
6" WYE AND �\ [-6" CITY STUB
45' BEND Y�
4" OR 6" J
SIDE SEWER CLEANOUT DETAIL
AT PROPERTY LINE/CITY EASEMENT
NOTES:
1. SEWER PIPE SHALL BE SDR-35 AND JOINTS SHALL BE
GASKETED.
2. PIPE SLOPE TO BE 2% MIN AND UP TO 50% MAX.
3. SEWER CLEANOUT COVER TO BE EAST JORDAN IRON WORKS
PRODUCT #00366102 STAR PIPE COSP48L OR APPROVED
EQUAL.
4. LEVELING COLLAR SHALL BE CONSTRUCTED AS FOLLOWS:
• IN ROADWAYS PER COE STD DWG GU-424
• IN SIDEWALK/LANDSCAPED AREAS, EITHER 24"x24"x6"
DEEP CONCRETE COLLAR OR 24" DIAMETER x 6" DEEP
CONCRETE COLLAR
CITY OF EDIvIONDS SEWER CLEANOUT DETAILS
PUBLIC WORKS
DEPARTMENT
APPROVED BY: R. ENGLISH
REVISION DATE
DECEMBER 2017
STANDARD
D ETAI L
SS-200
SW1/4, SEC 31, TWP 27N, RGE 4E, W.M.
6" MIN DEPTH
3- SET DEPTH AS REQ D FOR POSI TI VE
fiRerfabric FLOW FROM WALL/HOUSE FOOTING DRAIN
compacted backfill
4' rigid or 6" flexible
perforated pipe
washed rock
1 1/2"-314'
ROOM
Iof
SECTION A
NTS
RETAINING WALL / FOOTING DRAIN
DRYWELL TRENCH
NOT TO SCALE
TESC NOTES
1. ESC MINIMUM REQUIREMENT -CONSTRUCTION ACCESS ROUT, CONSTRUCTION VEHICLE ACCESS SHALL BE, WHENEVER
PRACTICAL, LIMITED TO ONE ROUTE. ACCESS POINTS SHALL BE STABILIZED WITH QUARRY SPALLS OR CRUSHED ROCK TO
MINIMIZE THE TRACKING OF SEDIMENT ONTO PUBLIC ROADS. IF SEDIMENT IS TRANSPORTED ONTO A ROAD SURFACE, THE
ROADS SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY. SEDIMENT SHALL BE REMOVED FROM ROADS BY
SHOVELING OR SWEEPING AND BE TRANSPORTED TO A CONTROLLED SEDIMENT DISPOSAL AREA WITHIN 24 HOURS. STREET
WASHING SHALL BE ALLOWED ONLY AFTER SEDIMENT IS REMOVED IN THIS MANNER.
2. ESC MINIMUM REQUIREMENT -STABILIZATION OF EXPOSED AREAS. ALL SOILS EXPOSED BY LAND DISTURBING ACTIVITIES
SHALL BE STABILIZED BY SUITABLE APPLICATION OF BMPS, INCLUDING, BUT NOT LIMITED, SOD, HYDROSEEDING, OR OTHER
VEGETATION, PLASTIC COVERING, OR MULCHING. ALL BMPS SHALL BE SELECTED, DESIGNED, AND MAINTAINED IN
ACCORDANCE WITH THE MANUAL. THE EXPOSED SOILS SHALL BE STABILIZED ACCORDING TO AN APPROVED TIMETABLE.
(TYPICALLY, NO SOILS SHALL REMAIN EXPOSED FOR MORE THAN TWO DAYS FROM OCTOBER 1 THROUGH APRIL 30 AND
NO MORE THAN SEVEN DAYS FROM MAY 1 THROUGH SEPTEMBER 30).
J. ESC MINIMUM REQUIREMENT -PROTECTION OF ADJACENT PROPERTIES. ADJACENT PROPERTIES SHALL BE PROTECTED FROM
SEDIMENT DEPOSITION BY APPROPRIATE USE OF VEGETATIVE BUFFER STRIPS, SEDIMENT BARRIERS OR FILTERS, DIKES OR
MULCHING, OR BY A COMBINATION OF THESE MEASURES AND OTHER APPROPRIATE BMPS.
4. ESC MINIMUM REQUIREMENT- MAINTENANCE. ALL EROSION AND SEDIMENT CONTROL BMPS SHALL BE REGULARLY
INSPECTED AND MAINTAINED BY THE OWNER TO ENSURE CONTINUED PERFORMANCE OF THEIR INTENDED FUNCTION. ALL
MAINTENANCE AND REPAIR SHALL BE CONDUCTED IN ACCORDANCE WITH THE MANUAL.
5. ESC MINIMUM REQUIREMENT -OTHER BMPS. AS REQUIRED BY THE CITY, OTHER APPROPRIATE BMPS TO MITIGATE THE
EFFECTS OF INCREASED RUNOFF SHALL BE APPLIED.
6. EROSION AND SEDIMENT CONTROL REQUIREMENT- UNDERGROUND UTILITY CONSTRUCTION. THE CONSTRUCTION OF
UNDERGROUND UTILITY LINES SHALL SPECIFICALLY ADDRESS THE FOLLOWING:
a. EROSION CONTROL FOR EXCAVATED AND STOCKPILED MATERIALS;
b. THE PLACEMENT OF EXCAVATED MATERIAL WHERE CONSISTENT WITH SAFETY AND SPACE CONSIDERATIONS SHALL BE
PLACED ON THE UPHILL SIDE OF TRENCHES;
C. TRENCH DEWATERING SYSTEMS (MUST DISCHARGE INTO SEDIMENT TRAPS, SEDIMENT PONDS, OR OTHER ACCEPTABLE
MEANS);
d. TRACKING AND SPILLING OF MATERIALS ON STREETS DUE TO HAULING;
e. DAILY CLEANUP AND STREET MAINTENANCE.
7. ADDITIONAL ESC MINIMUM REQUIREMENTS FOR LARGER DEVELOPMENTS. ALL NEW DEVELOPMENT AND REDEVELOPMENT
THAT INCLUDED LAND DISTURBING ACTIVITIES OF GREATER THEN, OR EQUAL TO, ONE ACRE IN ADDITION TO MEETING THE
MINIMUM REQUIREMENTS SET FORTH ABOVE SHALL COMPLY WITH ESC REQUIREMENTS LISTED BELOW.
8. ESC MINIMUM REQUIREMENT- DELINEATE CLEARING AND EASEMENT LIMITS. IN THE FIELD, MARK CLEARING LIMITS AND/OR
ANY EASEMENTS, SETBACKS, SENSITIVE/CRITICAL AREAS AND THE BUFFERS, TREES AND DRAINAGE COURSES.
9. ESC MINIMUM REQUIREMENT -SEDIMENT TRAPPING. PRIOR TO LEAVING THE SITE, STORM WATER RUNOFF SHALL PASS
THROUGH A SEDIMENT POND OR SEDIMENT TRAP, OR OTHER APPROPRIATE BMPS. SEDIMENT PONDS AND TRAPS,
PERIMETER DIKES, SEDIMENT BARRIERS, AND OTHER BMPS INTENDED TO TRAP SEDIMENT ON -SITE SHALL BE
CONSTRUCTED AS A FIRST STEP IN GRADING. THESE BMPS SHALL BE FUNCTIONAL BEFORE LAND DISTURBING ACTIVITIES
TAKE PLACE. EARTHEN STRUCTURES, SUCH AS DAMS, DIKES, AND DIVERSIONS SHALL BE SEEDED AND MULCHED
ACCORDING TO AN APPROVED TIMETABLE.
10. ESC MINIMUM REQUIREMENT -CUT AND FILL SLOPES. CUT AND FILL SLOPES SHALL BE DESIGNED AND CONSTRUCTED IN A
MANNER THAT WILL MINIMIZE EROSION. IN ADDITION, SLOPES SHALL BE STABILIZED IN ACCORDANCE WITH ESC
REQUIREMENT NO. 2.
11. ESC MINIMUM REQUIREMENT -CONTROLLING OFF -SITE EROSION. PROPERTIES AND WATER WAYS DOWNSTREAM FROM
DEVELOPMENT SITES SHALL BE PROTECTED FROM EROSION DUE TO INCREASES IN THE VOLUME, VELOCITY, AND PEAK
FLOW RATE OF STORM WATER RUNOFF FROM THE PROJECT SITE.
12. ESC MINIMUM REQUIREMENT -STABILIZATION OF TEMPORARY CONVEYANCE CHANNELS AND OUTLETS. ALL TEMPORARY
ON -SITE CONVEYANCE CHANNELS SHALL BE DESIGNED, CONSTRUCTED AND STABILIZED TO PREVENT EROSION FROM THE
EXPECTED VELOCITY OF FLOW FROM A TWO-YEAR, 24-HOUR FREQUENCY STORM FOR THE DEVELOPED CONDITION.
STABILIZATION ADEQUATE TO PREVENT EROSION OF OUTLETS, ADJACENT STREAM BANKS, SLOPES AND DOWNSTREAM
REACHES SHALL BE PROVIDED AT THE OUTLETS OF ALL CONVEYANCE SYSTEMS.
13. ESC MINIMUM REQUIREMENT -STORM DRAIN INLET PROTECTION. ALL STORM DRAIN INLETS MADE OPERABLE DURING
CONSTRUCTION SHALL BE PROTECTED SO THAT STORM WATER RUNOFF SHALL NOT ENTER THE CONVEYANCE SYSTEM
WITHOUT FIRST BEING FILTERED OR OTHERWISE TREATED TO REMOVE SEDIMENT.
14. ESC MINIMUM REQUIREMENT -REMOVAL OF TEMPORARY BMPS. ALL TEMPORARY EROSION AND SEDIMENT CONTROL BMPS
SHALL BE REMOVED WITHIN 30 DAYS AFTER FINAL SITE STABILIZATION IS ACHIEVED OR AFTER THE TEMPORARY BMPS
ARE NO LONGER NEEDED. TRAPPED SEDIMENT SHALL BE REMOVED OR STABILIZED ON SITE. DISTURBED SOIL AREAS
RESULTING FROM REMOVAL SHALL BE PERMANENTLY STABILIZED.
15. EROSION AND SEDIMENT CONTROL REQUIREMENT-DEWATERING CONSTRUCTION SITES. DEWATERING SYSTEMS SHALL
DISCHARGE INTO A SEDIMENT TRAP OR SEDIMENT POND.
16. EROSION AND SEDIMENT CONTROL REQUIREMENT -CONTROL OF POLLUTANTS OTHER THAN SEDIMENT ON CONSTRUCTION
SITES. ALL POLLUTANTS OTHER THAN SEDIMENT THAT OCCUR ON SITE DURING CONSTRUCTION SHALL BE HANDLED AND
DISPOSED OF IN A MANNER THAT DOES NOT CAUSE CONTAMINATION OF STORM WATER.
17 EROSION AND SEDIMENT CONTROL REQUIREMENT -FINANCIAL LIABILITY. PERFORMANCE BONDING, OR OTHER APPROPRIATE
FINANCIAL INSTRUMENTS, SHALL BE REQUIRED FOR ALL PROJECTS TO ENSURE COMPLIANCE WITH THE APPROVED EROSION
AND SEDIMENT CONTROL PLAN. [ORD. 3013 1, 1995]..
GENERAL NOTES
1. ALL MATERIALS AND WORK SHOWN ON THESE PLANS SHALL CONFORM TO THE CITY OF EDMONDS STANDARD PLANS AND
DETAILS, THE FOLLOWING SPECIFICATIONS AND CODES, AND ALL OTHER APPLICABLE LOCAL MUNICIPAL, STATE, AND
FEDERAL CODES, RULES AND REGULATIONS.
- CURRENT INTERNATIONAL BUILDING CODE (IBC)
- CURRENT WSDOT/APWA STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION
- 2012 WASHINGTON STATE DEPARTMENT OF ECOLOGY STORMWA TER MANAGEMENT MANUAL FOR WESTERN WASHINGTON
(AS AMENDED IN DECEMBER 2014)
2. STANDARD PLAN AND TYPE NUMBERS INDICATED ON THESE DRAWINGS REFER TO CITY OF EDMONDS STANDARD DETAILS,
UNLESS NOTED OTHERWISE
J. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOBSITE WHENEVER CONSTRUCTION IS IN PROGRESS.
4. DEVIATIONS FROM THESE PLANS MUST BE APPROVED BY THE ENGINEER OF RECORD AND THE LOCAL GOVERNING
AUTHORITY.
5. CONTRACTOR SHALL RECORD ALL APPROVED DEVIATIONS FROM THESE PLANS ON A SET OF 'AS -BUILT" DRAWINGS AND
SHALL SUMMARIZE ALL ASBUILT CONDITIONS ON ONE SET OF REPRODUCIBLE DRAWINGS FOR SUBMITTAL TO THE OWNER
PRIOR PROJECT COMPLETION AND ACCEPTANCE. A SET OF AS -BUILT DRAWINGS SHALL BE SUBMITTED TO THE CITY OF
EDMONDS PRIOR TO FINAL APPROVAL OF THE BUILDING OCCUPANCY/FINAL PROJECT APPROVAL.
6. ELEVATIONS SHOWN ARE IN FEET. SEE SURVEY FOR BENCHMARK INFORMATION.
7. THE LOCATIONS OF EXISTING UTILITIES AND SITE FEATURES SHOWN HEREON HAVE BEEN FURNISHED BY OTHERS BY FIELD
SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHOULD THEREFORE BE CONSIDERED APPROXIMATE ONLY AND
NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE
ACCURACY OF ALL UTILITY LOCATIONS SHOWN AND TO FURTHER DISCOVER AND PROTECT ANY OTHER UTILITIES NOT
SHOWN HEREON WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. CONTRACTOR SHALL VERIFY
LOCATION, DEPTH, SIZE, TYPE AND CONDITION OF EXISTING UTILITY LINES AT CONNECTION OR CROSSING POINTS BEFORE
TRENCHING FOR NEW UTILITIES. ENGINEER ASSUMES NO RESPONSIBILITY FOR THE COMPLETENESS OR ACCURACY OF THE
EXISTING UTILITIES AND SITE FEATURES PRESENTED ON THESE DRAWINGS. ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF
CONFLICTS THAT ARISE.
8. CONTRACTOR SHALL LOCATE AND PROTECT ALL UTILITIES DURING CONSTRUCTION AND SHALL CONTACT THE
UNDERGROUND UTILITIES LOCATION SERVICE (1-800-424-5555) AT LEAST 48 HOURS PRIOR TO CONSTRUCTION.
9. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE PROJECT SITE BEFORE STARTING WORK AND
SHALL NOTIFY OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES.
10. PIPE LENGTHS WHERE SHOWN ARE APPROXIMATE AND MAY CHANGE DUE TO FIELD CONDITIONS.
11. CONTRACTOR SHALL OBTAIN A COPY OF THE GEOTECHNICAL REPORT (WHERE APPLICABLE) AND SHALL THOROUGHLY
FAMILIARIZE HIMSELF WITH THE CONTENTS THEREOF. ALL SITE WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH
THE RECOMMENDATIONS OF THIS REPORT.
12. STRUCTURAL FILL MATERIAL AND PLACEMENT SHALL CONFORM TO THE RECOMMENDATIONS OF THE PROJECT
GEOTECHNICAL REPORT.
13 SUBGRADE SOILS IN ALL AREAS WHERE RAIN GARDENS, INFILTRATION OR PERVIOUS PAVEMENT IS TO BE PLACED SHALL
BE DELINEATED AND PROTECTED AT ALL TIMES FROM COMPACTIVE ACTIVITIES (I.E. HEAVY EQUIPMENT, STOCKPILING).
14. MANHOLES, CATCH BASINS, UTILITIES AND PAVEMENT SHALL BEAR ON MEDIUM DENSE TO VERY DENSE NATIVE SOIL OR
COMPACTED STRUCTURAL FILL. IF SOIL IS DISTURBED, SOFT, LOOSE, WET OR IF ORGANIC MATERIAL IS PRESENT AT
SUBGRADE ELEVATION, REMOVE AND REPLACE WITH COMPACTED STRUCTURAL FILL PER GEOTECHNICAL REPORT.
15. SEE SURVEY AND ARCHITECTURAL DRAWINGS FOR DIMENSIONS AND LOCATIONS OF BUILDINGS, LANDSCAPED AREAS AND
OTHER PROPOSED OR EXISTING SITE FEATURES.
16. SEE ARCHITECTURAL DRAWINGS FOR PERIMETER FOUNDATION DRAINS. FOUNDATION DRAINS SHALL BE INDEPENDENT OF
OTHER SITE DRAIN LINES AND SHALL BE TIGHTLINED TO THE STORM DRAIN SYSTEM WHERE INDICATED ON THE PLANS.
17 ALL REQUIRED STORMWA TER FACILITIES MUST BE CONSTRUCTED AND IN OPERATION PRIOR TO INSTALLATION OF ANY
PAVEMENT UNLESS OTHERWISE APPROVED BY THE ENGINEER.
18. ALL ROOF DRAINS, PERIMETER FOUNDATION DRAINS, CATCH BASINS AND OTHER EXTERNAL DRAINS SHALL BE CONNECTED
TO THE STORM DRAINAGE SYSTEM, UNLESS NOTED OTHERWISE.
19. ALL FOOTING DRAINS SERVING BUILDINGS, WALLS, ROCKERIES, ETC. SHALL CONNECT TO THE DRAINAGE SYSTEM.
20. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS REQUIRED FOR INSTALLATION OF ALL SITE IMPROVEMENTS
INDICATED ON THESE DRAWINGS.
21. A SEPARATE IRRIGATION PERMIT MUST BE OBTAINED FROM THE CITY PUBLIC WORKS DEPARTMENT. PRIOR TO FINAL
CONSTRUCTION ACCEPTANCE, PROVIDE TO THE CITY WATER QUALITY TECHNICIAN, A COPY OF THE BACKFLOW TEST
REPORT. TEST REPORTS CAN BE FAXED TO 425-744-6057 OR EMAILED TO JEFF.KOBYLK@EDMONDSWA.GOV. BACKFLOW
TESTING SHALL BE COMPLETED BY THE OWNER ANNUALLY THEREAFTER.
22. AS A MINIMUM REQUIREMENT, ALL DISTURBED AREAS ON AND OFF SITE SHALL BE RETURNED TO THE EQUIVALENT OF
THEIR PRECONSTRUCTION CONDITION IN ACCORDANCE WITH APPROPRIATE REQUIREMENTS AND STANDARDS.
23. ALL DISTURBED SOIL AREAS SHALL BE COMPOST AMENDED AND SEEDED OR STABILIZED BY OTHER ACCEPTABLE
METHODS FOR THE PREVENTION OF ONSITE EROSION AFTER THE COMPLETION OF CONSTRUCTION. SEE EROSION CONTROL
PLANS FOR SPECIFIC GRADING AND EROSION CONTROL REQUIREMENTS.
24. THE CONTRACTOR SHALL KEEP OFF -SITE STREETS CLEAN AT ALL TIMES BY SWEEPING. WASHING OF THESE STREETS WILL
NOT BE ALLOWED WITHOUT PRIOR APPROVAL.
25. THIS PROJECT IS NOT A BALANCED EARTHWORK PROJECT. BOTH EXPORT AND IMPORT OF SOIL AND ROCK MATERIALS
ARE REQUIRED.
26. SLOPE OF FINISHED GRADE SHALL BE CONSTANT BETWEEN FINISHED CONTOURS OR SPOT ELEVATIONS SHOWN.
27. FINISHED GRADE SHALL SLOPE AWAY FROM BUILDING WALLS AT MINIMUM 57 SLOPE FOR A MINIMUM DISTANCE OF 10
FEET.
28. CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL INSTALL AND MAINTAIN SHORING AND BRACING AS NECESSARY
TO PROTECT WORKERS, EXISTING BUILDINGS, STREETS, WALKWAYS, UTILITIES AND OTHER EXISTING AND PROPOSED
IMPROVEMENTS AND EXCAVATIONS AGAINST LOSS OF GROUND OR CAVING EMBANKMENTS. CONTRACTOR SHALL ALSO BE
RESPONSIBLE FOR REMOVAL OF SHORING AND BRACING, AS REQUIRED.
29. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE CITY AND FOLLOW CITY PROCEDURES FOR ALL WATER SERVICE
INTERRUPTIONS, HYDRANT SHUTOFFS, STREET CLOSURES OR OTHER ACCESS RESTRICTIONS. CONTRACTOR SHALL NOT
RELOCATE OR ELIMINATE ANY HYDRANTS WITHOUT FIRST OBTAINING WRITTEN APPROVAL FROM THE FIRE MARSHAL.
30. COORDINATE AND ARRANGE FOR ALL UTILITY CONNECTIONS, UTILITY RELOCATIONS AND/OR SERVICE INTERRUPTIONS WITH
THE AFFECTED OWNERS AND APPROPRIATE UTILITY COMPANIES. CONNECTIONS TO EXISTING UTILITIES SHALL BE MADE
ONLY WITH ADVANCE WRITTEN APPROVAL OF THE AUTHORITIES GOVERNING SAID UTILITIES.
31. ALL UTILITIES SHALL BE PLACED UNDERGROUND.
32. EXISTING UTILITY LINES IN SERVICE WHICH ARE DAMAGED DUE TO CONSTRUCTION WORK SHALL BE REPAIRED AT
CONTRACTOR'S EXPENSE AND INSPECTED AND ACCEPTED BY CITY OF EDMONDS AND OWNER'S REPRESENTATIVE PRIOR
TO BACKFILLING.
33 NEW UTILITY LOCATIONS ARE GENERALLY SHOWN BY DIMENSION, WHERE NO DIMENSIONS ARE INDICATED, LOCATIONS MAY
BE SCALED FROM DRAWINGS. FIELD ADJUSTMENTS SHALL BE APPROVED BY OWNER'S REPRESENTATIVE AND CITY.
34. FIELD STAKE ALL UTILITY STUBS AT THE PROPERTY LINE.
35. TRENCH BACKFILL OF UTILITIES LOCATED WITHIN THE CITY RIGHT-OF-WAY SHALL BE COMPACTED TO 959: COMPACTION
TEST REPORTS SHALL BE PROVIDED TO THE CITY PRIOR TO PAVING.
36. WHERE NEW PIPE CLEARS AN EXISTING OR NEW UTILITY BY 6" OR LESS, PLACE POLYETHYLENE PLASTIC FOAM AS A
CUSHION BETWEEN THE UTILITIES.
37. SEE MECHANICAL DRAWINGS (WHERE APPLICABLE) FOR CONTINUATION OF SITE UTILITIES WITHIN THE BUILDING.
38. SEE ELECTRICAL DRAWINGS (WHERE APPLICABLE) FOR EXTERIOR ELECTRICAL WORK.
39. SEE LANDSCAPE DRAWINGS (WHERE APPLICABLE) FOR SITE IRRIGATION SYSTEM.
40. PIPE MATERIAL AND SIGNAGE SUBMITTALS SHALL BE PROVIDED TO CITY ENGINEERING DIVISION FOR APPROVAL PRIOR TO
INSTALLA TION.
Know what's below.
Call before you dig.
BLD2020-0378
APPROVED FOR CONSTRUCTION
CITY OF EDMONDS
DATE:
BY
CITY ENGINEERING DIVISION
RAM
ENGINEERING, INC.
Civil Engineering / Land Planning
16531 13TH AVE W, SUITE Al08
LYNNWOOD, WA 98037
PHONE: (425) 678-6960
WWW.RAMENGINEERINGINC.COM
ti
O
go WA l�
d
36508 W
�EGISTER�9
T .�/
16/5/ZO
Z
Z
CA
to
Q
W
ENGINEER:
ROB L. LONG, PE
DRAWN BY:
MIKE MORRIS
ISSUE DATE: SCALE.•
J14120 AS NOTED
JOB NO:
19-014
SHEET.•
GN-01
SH T 3 OF 3