BLD2021-0746_Manufacturer_Specifications_and_Installation_Instructions_6.1.2021_3.28.10_PM_2226334A*& feW s�wdard H EATI N G & Al R CON D ITI ONING 4A6H7036B-SUB-1 C-EN 3 Ton Split System Heat Pump —1 Ph NOTE: All dimensions are in mm/inches. 4A6H7036B FiN37[�IN•LIDW� ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES. TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 152E 15 FEET) ABOVE UNIT. UNIT SHOULD BE PLACED SO ROOF AUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 305 (12'.) FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED. —T.. — 22.2 (118) DIA. HOt LOW VOLTA( 28.6 ll-1/8) DIA. K. WITH 22.2 (T/81 DI HOLE IN CONTROL E BOTTOM FOR ELECTRICI POWER SUPS LIQUID LINE SERVICE — VALVE, 'E" I.D. FENT BRAZE CONNECTION WITH I/4 " SAE FLARE PRESSURE TAP FITTING: irnillW��IWWt� it�i� I III i.Y iE I1/I I�I �a IIII`:I11111 m� liliiilnlw i _will FIG. t J N.O. FOR ALTERNATE G ELECTRICAL ROUTING AS LINE I/E TURN BALL SERVICE VALVE, 'D' I.D. FEMALE BRAZED CONNECTION WITH I/E SAE FLARE PRESSURE TAP FITTING. From li D152862 Rev.26 MODELS I BASE I A I B I C I D I E I F I G H J K 4A6H703613 4 1045 946 870 3/4 3/8 152 (6) 98 219 86 711 (41-1/8) (37-1/4) (34.1/4) (3-7/8) (8-5/8) (3-3/8) (28) Product Specifications OUTDOOR UNIT (DQz 4A6H7036B1000DA POWER CONNS.—V/PH/HZ QQ 208/230/1/60 MIN. BIRCH. CIR. AMPACITY 20 BR. CIR. PROT. RTG. — MAX. (AMPS) 35 COMPRESSOR DURATION TIA -SCROLL NO. USED - NO.STAGES 1-2 VOLTS/PH/HZ 208/230/1/60 R.L. AMPS 07 - L.R. AMPS 15.3 - 83 FACTORY INSTALLED START COMPONENTS Q NO INSULATION/SOUND BLANKET NO COMPRESSOR HEAT YES OUTDOOR FAN PROPELLER DIA. (IN.) - NO. USED 27.6 - 1 TYPE DRIVE - NO. SPEEDS DIRECT - 1 CFM @ 0.0 IN. W.G. ® 3200 NO. MOTORS - HP 1 - 1/8 MOTOR SPEED 1 835 VOLTS/Pi 200/230/1 /60 F.L. AMPS 0.71 OUTDOOR COIL —TYPE SPINE FIN TIA ROWS - F.P.I. 1 - 24 FACE AREA (SQ. FF.) 27.87 TUBE SIZE (IN.) 3/8 REFRIGERANT CONTROL EEV REFRIGERANT R-410A LBS. — R-410A (O.D. UNIT) Qs 9 LBS.- 4 OZ. FACTORY SUPPLIED YES LINE SIZE - IN. O.D. GAS © 3/4 LINE SIZE - IN. O.D. LIQ. © 3/8 CHARGING SPECIFICATION SUBCOOLING 11 °F DIMENSIONS H X W X D CRATED (IN.) 46.4 X 35.1 X 38.7 WEIGHT SHIPPING (LBS.) 258 NET (LBS.) 210 O Certified in accordance with the Air -Source UnitaryAir-conditioner Equipment certification program, which is based on AHRI standard 210/240. In order to achieve AHRI standard rating, the indoor fan time delay on the comfort control must be enabled. OO Rated in accordance with AHRI standard 270. ( Calculated in accordance with Nall. Elec. Codes. Use only HACR circuit breakers Or fuses. EO Standard Air — Dry Coll —Outdoor Os This value approximate. For more precise value see unit nameplate. © Max. linear length 60 it.; Max. lift - Suction 25 ft.; Max lift - Liquid 25 ft. For greater length consult refrigerant piping software Pub. No. 323312-0' (` denotes latest revision). (D This value shown for compressor F LA on the unit nameplate and on this specification sheet is used to compute minimum branch Circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. Op No means no start components. Yes means quick start Wtcomponents. PTCmeans positive temperature coefficient sta for. Sound Power Level Model A -Weighted Sound Power Level [dB(A)] Full Octave Sound Power [dB] 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4A6H7036B1 72 66 1 66 1 64 1 64 1 63 1 57 1 54 48 Note: Rated in accordance with AHRI Standard 270-2008 0 2019 American Standard Heating & Air Conditioning Mechanical Specification Options General The 4A6H7 is fully charged from the factory for matched indoor section and up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide se- lection of air handlers and furnace coils that are AHRI certified. The unit shall be certified to UL 1995. Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, G60 galvanized steel and paint- ed with a weather -resistant powder paint on all louvers and panels. Corrosion and weatherproof CMBP-G30 DuraBaseTM base. Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and high pressure switch. High and low pressure controls are inherent to the compressor. A factory installed liquid line drier is standard. Compressor The Duration ° 2-stage compressor features internal over temperature and pressure protection and hermetic motor. Other features include: roto lock suction and discharge refrigerant connections, centrifugal oil pump and modular plugs for electrical connections. loeori6" �S7iWdVd HEATING & AIR CONDITIONING Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured, this unit has a cool- ing capability to 55°F. For low ambient cooling below 55' see Application Guide APP-APG014-EN. C us O'T� STE Intertek 06/19 American Standard Heating & Air Conditioning www.americanstandardair.com American Standard Heating & Air Conditioning has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.