Loading...
BLD2018-15851 GK�4,0 OFE D�o� CITY OF EDMONDS 121 5TH AVENUE NORTH - EDMONDS, WA 98020 4c 1890 PHONE: (425) 771-0220 - FAX: (425) 771-0221 STATUS: ISSUED 07/08/2019 a Permit #: BLD20181585 Expiration Date: 07/08/2020 Project Address: 942 ALDER ST, EDMONDS Parcel No: 00434207101300 , , 1 , y , 1 M0 .APPLICANT CONTRACTOR ERNIE AND TINA DUECK ENCORE CONSTRUCTION ENCORE CONSTRUCTION 932 ALDER ST C/O DIMITRI LOKHMATOV C/O DIMITRI LOKHMATOV EDMONDS, WA 98020 7910 123RD AVE NE 7910 123RD AVE NE LK STEVENS, WA 98258 LK STEVENS, WA 98258 (425)359-9896 (425)359-9896 LICENSE #: ENCORCL8571(6 EXP:05/26/2019 JOB 1 11► ADDITION OF LIVING SPACE AND DECK - CONVERT EXISTING BASEMENT FOR USE AS AN ADU -MECHANICAL AND PLUMBING INCLUDED VALUATION: $112,789 PERMIT TYPE: Residential PERMIT GROUP: 02 - Addition-- GRADING: N CYDS: 0 TYPE OF CONSTRUCTION: VB RETAINING WALL ROCKERY: OCCUPANT GROUP: IRC SFR W/ADU OCCUPANT LOAD: FENCE: 0 X 0 FT. CODE: 2015 IEBC/IRC/UPC/WSEC OTHER: ------- OTHERDESC: ZONE: RS-6 NUMBER OF STORIES: 2 VESTED DATE: NUMBER OF DWELLING UNITS: 1 ILOT #: BASEMENT: 962 1ST FLOOR: 1050 2ND FLOOR: 0 '1 PO S ED BASEMENT: 0 IST FLOOR: 808 2ND FLOOR: 0 3RD FLOOR: 0 GARAGE: 534 DECK: 16 OTHER: 0 3RD FLOOR: 0 GARAGE: 0 DECK: 947 OTHER: 0 BEDROOMS:3 BATHROOMS:2 BEDROOMS:3 BATHROOMS:I FRONT1 :SETBACK REQUIRED:20' PROPOSED:18.91'N REQUIRED:5' PROPOSED:5'E REQUIRED:15' PROPOSED:36'S HEIGHT ALLOWED:O PROPOSED:O REQUIRED: 5' PROPOSED: PW SETBACK NOTES: Not change to existing setbacks. I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMENS COMPENSATION INSURANCE AND RCW 18:27. r,I THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED PY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. Signature ' Print Name Released By 7/8/19 Date ATTENTION ITIS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. UBC109/ IBCI 10/ IRCI 10. FIRE APPLICANT ASSESSOR r1TY 09 STATUS: ISSUED BLD20181585 CONDITIONS • Installation, use and maintenance of equipment and components shall be per manufacturer's specifications, installation instructions, and applicable state codes. Provide manufacture's installation instructions on site for Building Inspector. • Approval of this foundation design is conditional subject to inspection of existing site soil conditions. • Retaining Walls must be designed and constructed to resist the lateral pressure of the retained material. • Provisions must be made for the control and drainage of surface water around buildings. • Installer shall provide the manufacturer's installation, operating instructions, and a whole house ventilation system operation description. A label shall be affixed to the whole house timer control that reads "Whole House Ventilation" (see operating instructions). • Maximum Height 25 feet. The agent/contractor shall set up the equipment; establish the datum point and the point of average grade. Call for inspection to verify. These items must be consistent with the approved plan. Ifthe proposed height of a building (as shown on the plans) is within 12 inches of the maximum height permitted for the zone an elevation survey is required. • Obtain Electrical Permit fi-om State Department of Labor & Industries. 425-290-1309 • Gas pipe test must be observed by City Building inspector, affidavits shall not be accepted. • Final approval on a project or final occupancy approval must be granted by the Building Official prior to use or occupancy of the building or structure. Check the job card for all required City inspections including final project approval and final occupancy inspections. • Any request for altemate design, modification, variance or other administrative deviation (hereinafter "variance") from adopted codes, ordinances or policies must be specifically requested in writing and be called out and identified. Processing fees for such request shall be established by Council and shall be paid upon submittal and are non-refundable. • Approval of any plat or plan containing provisions which do not comply with city code and for which a variance has not been specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision of city code or state law does not approve any items not to code specification. • Sound/Noise originating fromtemporary construction sites as a result of construction activity are exempt fromthe noise limits of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. • Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly from the issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. • Maintain erosion & sedimentation control per city standards. • Nothing in this permit approval process shall be interpreted as allowing or permitting the maintenance of any currently existing illegal, nonconfomung or unpermitted building, structure or site condition which is outside the scope ofthe pen -nit application, regardless of whether such building, structure or condition is shown on the site plan or drawing. Such building, structure or condition may be the subject of separate enforcement action. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT TIME LIMIT: SEE ECDC 19.00.005(A)(6) BUILDING I IENGINEERING (425) 771-0220 EXT. 1326 1 1. Go to: www.edmondswa.gov Building Department Inspections 2. Then: Services are now scheduled online. If you 3. Then: Permits/Development have difficulties, please call the 4. Then: Online Permit Info Building Department front desk for 5: If you don't have one already, create a assistance during office hours. FIRE (425) 775-7720 PUBLIC WORKS (425) 771-0235 4 login (upper right hand corner) I (425) 771-0220 I RECYCLING (425) 275-4801 6: Schedule your inspection When calling for an inspection please leave the following information: Permit Number, Job Site Address, Type of Inspection being requested, Contact Name and Phone Number, Date Preferred, and whether you prefer morning or afternoon. • E-Erosion Control/Mobilization • E-Engineering Final • B-Preconstruction meeting • B-Footings • B-Foundation Wall • B-Foundation Drainage • B-Isolated Footings/Piers • B-Plumb Ground Work • B-Plumb Rough In • B-Gas Test/Pipe • B-Mechanical Rough In • B-Ext Wall-Sheathing/Nailing • B-Roof Sheathing • B-Window Flashing • B-Height Verification • B-Framing-Smoke/CO Alarms • B-Insulation/Energy • B-SheetrockNail • B-Building Final • B-Other COMMERCIALGENERAL DATA Occupancy Group(s): Occupant Load(s): Type(s) of Construction: Fire Sprinklers: Yes ❑ No ❑ WA STATE ENERGY CODE: If your project affects the building envelope, mechanical systems, and/or lighting, you must complete the appropriate WSEC forms. DEFERRED SUBMITTALS: All commercial building permits that will require associated plumbing, mechanical, fire sprinkler, and/or fire alarm permits are applied for separately. TI / CHANGE OF USE / NEW BLDG: Include TRAFFIC IMPACT worksheet EQUIPMENTMECHANICAL • BTUs Gas / Elec / Other Qty A/C Unit /Compressor Air Handler /VAV Boiler Dryer Duct Exhaust Fans 5 Fireplace ' Furnace Heat Pump Unit Hydronic Heating Roof Top Unit (Provide eleva- tions if a Commercial Bldg) Other: COUNTSPLUMBING FIXTURE Qty Qty Clothes Washer 2 Tub/ Showers (( Z. Dishwasher 1 Z Backflow Device (RPBA, DCDA, AVB) Drinking Fountain Pressure Reduction/ Regulator Valve Floor Drain/Sink Refrigerator Water Supply Hose Bibs Water Heater - Tankless?&r N Hydronic Heat Water Service Line ll)I Sinks y Other: Toiletsi 2 Other: GAS/FUEL CONNECTION COUNTS (New, Relocated or re -piped) BTUs Qty BTUs Qty A/C Unit Outdoor BBQ/ Fire pit Boiler Stove/Range/Oven Dryer Water Heater ' Fireplace/ Insert Other: Furnace I I GAS, Other: COUNTSMEDICAL AIR VACUUM .. .. •. Qty Qty Carbon Dioxide Nitrous Oxide Helium Oxygen Medical Air Other: Medical - Surgical Vacuum Other: DEMOLITION Type of structure to be demolished: Square footage of structure to be demolished: AHERA Survey done? Y / N PSCAA Case #: Critical Areas Determination: Study Required ❑ Conditional Waiver ❑ Waiver ❑ Fill in Place ❑ Fill Material: Removal ❑ Size of Tank (Gallons) Critical Areas Determination: Study Required ❑ Conditional Waiver ❑ Waiver ❑ .D Grading: Cut cubic yards Fill cubic yards Cut / Fill in Critical Area: Yes ❑ No ❑ GENERAL PROVISIONS APPLICATIONS: Applications are valid for a maximum of 1 year. ESLHA Applications, 2 years. LICENSING: All contractors and subcontractors are required to be licensed with Washington State Department of Labor & Industries and have a current City of Edmonds Business License. SINE PLAN SCALE: 1 "=20.00' L_ a 10, 20' 30' SITE ADDRESS 942 ALDER STREET EDNIONDS, WA 98020 OWNER ERNIE DUECK 942 ALDER STREET EDMONDS, WA 98020 ASSESSOR'S PARCEL NO. 00434207101300 ZONING R" DRAINAGE ORIGINAL CONSTRUCTION:1947 EXISTING IMPERVIOUS AREA: 2878 SF NEW IMPERVIOUS AREA: 643 SF MISCELLANEOUS NOTES _ • FILTER SOCKS TO BE ADDED TO ANY CATCH BASINS DOWNSTRAM FROM THE CONSTRUCTION SITE. SEE DETAIL E1.3. • ALL DISTURBED SOILS SHALL BE COMPOST AMENDED PER BMP T5.13. • SEE DETAIL E1.1 FOR SILT FENCING DETAILS. • EXISTING SWIMMING POOL TO BE FILLED PER GEOTECHNICAL SPECIFICATIONS. OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING ALL ON -SITE UTILITIES. RELOCATIOWREVISION TO ANY UTILITIES MAY REQUIRE SEPARATE PERMIT. LOT SIZE 9,880 SQ. FT. BUILDING FOOTPRINT EXISTING BUILDING: 1778 SO. FT. NEW ADDITION: 484 TOTAL: 2262 LOT COVERAGE: 22.9% IMPERVIOUS SURFACE AREA EXISTING ROOF 2245 SQ. FT. EXISTING DRIVE & WALKS 1341 NEW ROOF 516 ---NEWi)E0t `"'147 TOTAL AREA 4209 SO. FT. TOTAL NEW AREA 623 HEIGHT CALCS A=306.0 30(° ' p/ B=302.15 �aZ.�s * t`ZiZ.S C-30'1.5 AY6 3c 1. S r 0 z� , 1 Z t D=30'1.5 Sol. S Sol.�f r = E=302.85 ` AVERAGE GRADE=392-78'• SOS' Z� MAX. ALLOWABLE HEIGHT=W_ TOP OF NEW RIDGE=327.20' DP= TOP OF SEWER MH IN STREET NEAR NW CORNER OF SITE @ 298.2' OWNEWONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DAMAGE "Nothing in this permit approval proe M-shall be inters retell as all,)wing or permitt;W the maintenance of any currently noncorfi,rming or un rmitted buildm� or site condition which it,, . •,tside the soaps of the permit ?application, rewrtirbg of whe er such bulkhng, structure or condition is shown on the site pp1a.1 or drawing. Such building. Wamebire or conditi:n, nx# ,y be the subject of a separate enforcement EXSITING NON -CONFORMING STRUCTURE (NO CHANGE) top of sewer mh @ 2982 O* 0 RM ALDER STPEET _ (CENTER OF R.O.W.) New deck above e xl 5t'vk4) avvL6�e . .-----DESIGNATED PARKING FOR A.D.U. EXISTING NON -CONFORMING CORNER OF GARAGE AND ROC TO REMAIN. = NEW 2ND FLOOR ABOVE _ _ _EXISTING GARAGE i I EXISTING WALKWAY i EXISTING GARAGE WALLS BELOW ---NEW STAIRS 443 z i --! ENTRANCE TSY - v3 u�. � BAS§FMENfA.D.U. mi SILT FENCE ih z B t im i 1 9 I BY EBl6 xL------------------------ ------------------- Zone 5-� �;orner�F Flag SetbaWks Actual Front \ Sides 5` _ S` E I' w Rear 1 •' — Other 89.92' CITY COPY 3U-) 2cig- i',�)�55 RECEIVED DEC 10 2018 BUILDING fpc. 1 g9lj CITY OF EDMONDS 12151^ Avenue North, Edmonds WA 98020 Phone: 425.771.0220 • Fax: 425.771.0221 • Web: www.edmondswa.eov, DEVELOPMENT SERVICES DEPARTMENT • PLANNING DIVISION CONDITIONAL USE PERMIT ACCESSORY DWELLING UNIT (ADU) Owner/Applicant: Ernst and Christina Dueck 942 Alder St. Ed o ds, WA 98020 Reviewed By: Bra pley Associate Planner File Number: PLN20180029 Date of Report: December 13, 2018 I. SUMMARY OF PROPOSED ACTION The applicant is proposing to build an Accessory Dwelling Unit (ADU) in the basement level of the existing house located at 942 Alder St. (Attachments 1-3). Approval of an ADU requires compliance with Edmonds Cornmunity Development Code (ECDC) Chapters 16.20 and 20.21. Pursuant to ECDC 20.01, an ADU is a Type 11 decision requiring public notice. II. COMPLIANCE WITH ECDC CHAPTER 16.20 The subject site is located within the RS-6 Single-Fainily Residential zone (Attachment 4). The purpose of the RS - single-family residential zone is to reserve and regulate areas primarily for family living in single-family dwellings and to provide for additional non- residential uses which complement and are compatible with single-family dwelling use. Pursuant to 17_7CDC 1620.010.D, an Accessory Dwelling Unit is an allowed secondary use with a conditional use permit. The proposal is required to comply with the purposes of the single-family residential zone and criteria outlined in Chapter 20.21. Based on staffs review of the specific ADU criterion (as described in Section III of this report), staff finds that the proposal is in compliance with the purposes of the single-family zone. III. COMPLIANCE WITH ECDC CHAPTER 20.21 Section 20.21.030 of the Edmonds Community Development Code provides the criteria by which Accessory Dwelling Units arc to be reviewed. The ADU criteria was crafted to ensure that A.DUs would comply with Chapter 16.20 of the Edmonds Community Development Code. In order for the permit to be approved, all of the criteria must be met. Detailed findings of staffs review of each criterion follows: Land Use Permit Required: Any person who occupies orpermits anotherperson to occupy an attached accessory dwelling unit as a place of residence shall first obtain a permit. The permit shall he reviewed and processed as a Type II decision (Staff decision - Notice required). The application was determined to be procedurally complete on May 14, 2018. In accordance with ECDC 20.03., a Notice of Application dated May 17, 2018 with a comment period ending on May 31, 2018 was mailed to property owners within 300-feet of the subject site based on the Adjacent Property Owners' List submitted by the applicant, posted at the subject site, the Public Safety Complex, Development Services Department, and Library. The notice of application was also published in the Herald Newspaper on May 17, 2018. Attachment 6 documents compliance with the public notice requirements of ECDC 20.03. Number of Units : A single,�amr.'� daa�elling may have no more than one accessory dwelling unit per lot. The City is aware that the applicant intends to apply for an addition to the primary residence that includes an additional kitchen above the garage. The occupancy of the primary residence, including the addition, shall not exceed the definition of "Family" per ECDC: 21.30.010. The ADU portion of the house may not exceed two persons per ECDC 21.30.010(D)(2). The proposal will result in only one A1)U and therefore is in compliance with the number of units allowed per ECDC 20.21.030(B). Size: In no case shall an accescog dwelling unit be (1) Larger than 40 percent of the livable floor area o f the principal dwelling; (2) nor more than 800 .square feet, (3) nor have more than two bedrooms; provided, if the accessoDi dwelling unit is completely located on a single floor, the planning manager may allow increased si.Ze up to 50 percent of the floor area of the principal dwelling in order to �ficienily use all floor area, so long as all other standards set fortis in this chapter are met. The existing primary residence has 2,372 square -feet of livable floor area and the ADU is proposed to consist of 1,094 square -feet and comprise 46.1-percent of the total livable floor area of the primary dwelling. Since the ADU is located on a single floor, staff has determined that the application meets the size criteria. The following table describes both the maximum size that Accessory Dwelling Units are allowed to be as well as the proposed size for this application: Dueck Accessory Dwelling Unit File No. PLN20180029 Page 2 of 7 MAXIMUM ALLOWED 50-percent of livable floor arca of the t)rimary dw Two bedrooms PROPOSED 46.1-percent of livable floor area of the i ary dwelling _ _ __ J Two Bedrooms 800-SF 1,094-SF' Location and Appearance: The single. family appearance and character of the 7e.� dence shall be mainlai7red rwhe7r 7 iezved f nna the su7ro7ending neighborhood. The design of the accessory d7velli77� 7at7it shall be incorporated into the desz',gtt of the pri77cipal dtt�ellitzg unit and shall be designed to mainlait7 the ar hitecttrrcrl design, s1J,/e, appearance and character of tl)e stain buildiq as a niggle family residence zrsi7g r»atchhig maleiials, colors, window style, and roof des.gn. 'The primary entrance to the accesso!)r dwelling unit shall be located in such a manner as to be w7obli-xvive 7when r roved p om the streel. Whenever possible, neiv entrances should be placed at the side or rear n f The building. Only one electizc and one water teeter shall be allowed./or the entire building, serving boll) the princa7), residence and the accesrog d�wellii7g ur7it. /1 cce.rso y <ha�ellit7g units must be located will7in or atlached to single fancily divelliiig units The proposed AD will be located on the basement level of the existing principal dwelling. The ADU entrance will be located on the rear of the residence and not visible from the street. Staff finds that the proposed AllU maintains the architectural design, style, appearance, and character of the main building and would not compromise the singe-fanuly appearance of the residence; therefore, the subject application complies with die location and appearance criteria. Parkin•: One of -.heel pa7kiq .pace in addition to /he parkin; spacer 7convallJ+ required Jor the principal dwelling shall be required to be provided for the accessory divellin, unit, but in no event less than lhree .spaces Per lot. The existing residence has an attached two -car garage in addition to space for three vehicles on driveway in the front of the residence. There is sufficient space for more than three off- street parking spaces; therefore, the application complies with 1-CDC 20.21.030.8. Occupancy: Tither the prince) diaielling or the accesro9t dwelling unit shall be owner-occ7.r�icd. `t77amer- occupied" shall ocean a property o7vner 7»ho stakes his or her /.egal r esidence at the site, as evidenced by voter tegislration, vehicle t-egisliation, or similar means, and aclttall i iv.(zdes at the site score than siv ntonlhs oul o f anygiven fear, and at no lithe receives rent for /he o7wner=occlipied unit.. The owner(v) shall not rent the designated owner -occupied unit at any lime during the pendency o f the AD (;permit; any such rental shall void the peymit.. 'The owners) shall not rent any portion of the owner -occupied residence either during the owner(,r)' occupancy or while the owner is absent from the owner -occupied unit for any period In no event shall t Per ECDC 20.21.030(C), if the accessoiy dNvclling unit is completely located on a single floor, the planning manager may allow increased size up to 50 percent of the floorarea of the principal d\velling in order to efficiently use all floor area, so long as all other standards set forth in this chapter are met. Ducck Accessory Dwelling Unit File No. PI,N20180029 Pale 3 of 7 the total number of occupants exceed one family as defined in this code; provided, however, that if the accessory dwelling unit is occupied by a nurse or other carrgiier assisting a disabled person who is an occupant of the principal residence, or the principal residence is occupied by a nurse/cargirler and the accesso y dwelling unit is occupied by a disabled person under the nurse's care, the occupancy limit of one famiy nvay be increased by one adililional unrelated person to a total of one family related hygenetics, adoption or mania plus one unrelated person, or a total a f six unrelated persons. In no event shall the total number of occupants exceed one family as defined in this code. The applicant has submitted a notarized affidavit to the City that meets this requirement (Attachment 8). The applicant must also file the Covenant required by ECDC 20.21.025.A.2 with the County Auditor following approval of the ADU. Safety} Light, Ventilation Floor Area, and Similar Factors: Acresso9i dwelling units .shall comply with all applicable requirements of the Uniform .Housing Code and the Un form Building Code adopted l y ECDC Title 19 and .shall. comply in all respects with the provisions of the Edmonds Community Development Code. No permit for an accessog dwelling unit .shall Ge issued to a nonconfvr�rrir�g stnvclure unless that str7scture is biwJ ght into con/bimance with the then current provisions of Ibis code. A condition of approval for this ADU has been added that requires compliance with the Building Division's inspection and compliance requirements. IV. PUBLIC COMMENTS Jim Carraway commented on the proposal noting that the basement has a history of being used as an ADU and was concerned that the initial proposal to establish an ADU in the proposed addition above the garage would create a third unit on a single family property. Mr. Carraway is concerned that this would create a precedent that could then be applied to other parts of the city. Janice and Gary Kirkpatrick live next door and are concerned about the loss of view from their property regarding the proposed addition (file no. BLD20181585) and noted that the basement is currently being rented out. Jay Magill had concerns similar to Mr. Carraway and the Kirkpatricks, stating that he is familiar with the subject house as his uncle built it in the late-1940's and knows that it has a full basement with living facilities. Mr. Magill is concerned that the establishment of an ADU will create a third individual family unit. Additionally, he is concerned that the addition of another unit will negatively impact the neighborhood by adding additional traffic and demands on infrastructure. Julie and Pat Perrine are concerned that the property was being rezoned from single-family to multi -family. STAFF RESPONSE: After consultation with the property owner and visit to the property, it was apparent that the basement is in fact being used as an ADU; however, the main level Dueck Accessory Dwelling Unit Pile No. PLN20180029 Page 4 of 7 and the proposed addition are to be occupied by one multi -generational. family, related by genetics or marriage. The applicant revised their application to establish a legal ADU in the existing basement. The home may be occupied by one family, as defined in ECDC 21.30.010, plus two additional persons in a legally -established ADU. In response to the Perrine comment, an ADU is an allowed conditional use within single- family zones. This is not a .rezone. V. TECHNICAL REVIEW The application was reviewed by Snohomish County Fire District #1 and the City of Edmonds' Building and Engineering divisions (Attachments 9-10). Snohomish County Fire District #1 and the Building Division had no comments. The Engineering Division found the proposal to be consistent with ECDC Title 18 (Attachment 10) VI. DECISION Based on statements of fact, conclusions, and attachments in this report, the application for a Conditional Use Permit for an Accessory Dwelling Unit at 924 Alder St. is APPROVED, subject to the following conditions: 1. The home may be occupied by one family, as defined in ECDC 21.30.010, plus up to two additional persons in the A.DU. 2. This permit shall expire automatically if any of the following issues arise: a. The Accessory Dwelling Unit is substantially altered and is thus no longer in conformance with the plans and drawings reviewed and approved by the permitting authority and Building Official; b. The subject site ceases to maintain the required number of parking spaces; c. The property owner ceases to reside in either the primary residence or the Accessory Dwelling Unit, the owner. -occupied unit is rented, or the current (or future) owner fails to file the ADU affidavit as required pursuant to ECDC 20.21.025(A)(1). 3. A building permit and/or compliance permit must be obtained from the Building Division and final inspection must be made and occupancy approval granted by the Dueck Accessory Dwelling Unit bile No. P1,N20180029 Page 5 of 7 City Building Inspector prior to the area being used as an ADU. Specific comments from the Building Division will be addressed during review of the applicable building pern-iit application. 4. The Accessory Dwelling Unit Covenant required under ECDC 20.21.025.A.2 must be filed with the Snohomish County Auditor. This covenant may be obtained from the Planning Division. Prior to occupancy of the Accessory Dwelling Unit, the applicant must either: a. Provide the City processing fee of $100 plus the County recording fee of $99 for one page, for a total of $199, and the City will record the covenant for you; OR b. Take the covenant to the County and record it for the County's recording fee of $99 for one page, and return a copy of the recorded covenant to the Edmonds Planning Division with the .Auditor's recording sticker on the COPY. 5. The Accessory Dwelling Unit permit shall not be transferable to any site other than the subject site described in the application. The Accessory Dwelling Unit permit is transferable to new owners of the subject property unless there is a violation of any conditions of approval listed above. New owners must file a notarized Accessory Dwelling Unit Affidavit with the City of Edmonds Planning Division. VII. ATTACHMENTS 1. Land Use Application 2. Site Plan 3. Floor Plan 4. Zoning and Vicinity .Map 5. Notice of Complete Application 6. Public Notice Documentation 7. Public Comments 8. Owner's Occupancy .Affidavit 9. Technical Review Comments 10. Engineering Memo of Compliance Dueck Accessory Dwelling Unit File No. 111..N20180029 Page 6 of 7 VIII. 01 PARTIES OF RECORD City of Edmonds 121 — 5"' Ave. N Edmonds, WA 98020 Dimitri Lokhmatov 7910 — 123' Ave. NE Lake Stevens, WA 98258 Jay Magill 925 Walnut St. Edmonds, WA 98020 Janice & Gary Kirkpatrick 948 Alder St. Edmonds, WA 98026 APPEALS Christine & Ernst Deuck 942 Alder St. Edmonds, WA 98020 Jim Carraway 944 Walnut St. Edmonds, WA 98020 Julie and Pat Perrin 401 —10' Ave. S. Edmonds, WA 98020 A party of record may submit a written appeal of a Type II decision within 14 days of the date of issuance of the decision. The appeal shall be made in writing and shall include all required information stated in EC.DC 20.07.004.D as well as the applicable fee. The appeal will be heard at an open record public hearing before the Hearing Examiner according to the requirements of ECDC Chapter 20.06 and Section 20.07.004. Dueck Accessory Dwelling Unit File No. 111,N20180029 Pagc 7 of 7 .11. 1 b' BUILDING PERMIT APPLICATION Development Services Building Division 121 5th Ave N / Edmonds, WA 98020 425.771.0220 For handouts, submittal requirements, permit status and inspection scheduling information go to: http://www.edmondswa.gov/ JOB SITE INFORMATION/LOCATION: (Where the work is taking place) Job Site Address: 7q2 Ader YWeel AeJxaoc1s 1VA 9�oZa Parcel: Lot /Unit/Suite #: Subdivision: PROPERTY OWNER: Name: &nl e 4 / 1�'IGt liue < Mailing Address: qq2 14Itl " ,Weeor City/State/Zip: %afyiJl oA, W11 riig'000 Phone #: Email OWNER INSTALLATION: *If yes, read and sign* Will work be performed by the property owner? ❑ Yes ❑ No I own, reside in, or will reside in the completed structure. This installation is being made on property that I own which is not intended for sale, lease, rent, or exchange according to RCW 18.27.090. Owner Signature: APPLICANT / CONTACT INFORMATION: Name of Applicant: tb/mi f /1 Z0kArn'910V Mailing Address: 7W /?-? ' /SUE me City/State/Zip: f KP shtle^14 (il A 'S'Z5 $ Phone #: l/25--_;5 —9"6 E-mail: 6lU1<14MA7OV(0/f-l/V/L . Cpi�a/ GENERAL CONTRACTOR: (If different from applicant) General Contractor:�L/LAC/ Mailing Address: City/State/Zip: Phone #: E-mail: WA STATE CONTRACTOR L & I # (CCB) & EXPIRATION DATE: CITY OF EDMONDS BUSINESS LICENSE #: ml K V 2_ UI 07 -! Office Use. Permit #: Z )j Q I ! 8 (ProvideTYPE OF PERMIT ccessoryStructureJ�c> Detached Garage ..- C -Addition od I , �'� lk ❑ Demolition ❑ Mechanical ❑ New Single Family / Duplex ❑ Plumbing ❑ Fire Sprinkler ❑ Remodel ❑ New Commercial/ Mixed Use ❑ Re -Roof ❑ Signs ❑ Tank ❑ Tenant Improvement ❑ Other Remodel Permit fees are based on: The value of the work performed. Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the work indicated on this application. Valuation: PROPOSED NEW SQUARE FOOTAGE FORTH IS APPLICATION Basement sq ft: Finished ❑ Unfinished ❑ 1st Floor, sq ft: 2nd Floor, sqft: 'W61i Garage/Carport:, sq ft: Deck/Covered Porch/Patio: 1 \ `Othersq ft: PROJECT DESCRIPTION AddfYlf, ao AddfYi'oyl Dye.r oei I certify that the information I have provided on this form/application is true, correct and complete, and that I am the property owner or duly authorized agent of the property owner to submit a permit application to the City of Edmonds. Print Name: ( ft A ' V Signature: Date -1Q--1 Ross Engineering Design Inc DUCK ADDITION STRUCTURAL CALCULATIONS 942 ALDER STREET, EDMONDS, WA 98020 Job Number 18016 Z .. w SS �CitSC� s10N�1. ELECTRONIC COPY ORIGINAL IS ON FILE .. " AT ROSS ENGINEERING r. ... . . ... .... For . " THE LEREN COMPANY Ross Engineering Design, Inc 425-314-2373 ...... l ryan ross@rossengineer com _: 5< • tt RECEIVED DEC 10 2018: BUILDING Page 1 of 36 Engineering Design Inc DUECK ADDITION STRUCTURAL CALCULATIONS 942 ALDER STREET, EDMONDS, WA 98020 Job Number 18016 ORIGINAL IS ON FILE AT ROSS ENGINEERING For THE LEREN COMPANY Ross Engineering Design, Inc 425-314-2373 ryan.ross@rossengineer.com Page 2 of 36 Results for LC 1, ASCE 2A.1-1 Full Model 1 Feb 20, 2018 at 7:39 PM DUECK ADDITION.rfl Page 3 of 36 BOSS Engineering Design Inc project: DUECK ADDITION by: RR sheet #: location: 942 ALDER STREET, EDMONDS, WA 98020 date: 2/20/2018 client: ITHE LEREN COMPANY job #: 18016 Governing Codes General - International Building Code - 2015 Wood - ANSI / AMPA NDS - 2015 ANSI / AMPA SDPWS - 2015 Loads - ASCE / SEI 7-10 Concrete - ACI 318 - 14 Building Input Information Plate Plate Heights Level Height 2 8.00 ft e' 1 9.00 ft r Floor Framing Depth 12 in Top Plate Height = 18 ft Roof Area = 820 sq ft 2 Area = 820 sq ft 1 Area = F sq ft (LEVEL 1 AREA ONLY USED FOR INTERIOR WALL WEIGHT CALCULATION) Level 2 Low Roof Area = 200 sq ft Floor 2 Side to Side Dimension 38' ft Floor 2 Front to Back Dimension 1 27 ft Floor 1 Side to Side Dimension 23.5 ft Floor 1 Front to Back Dimension 1 23.75 ft Average Roof Height ;= 21 ft Roof Rise per 12 ft = 5 ft Page 4 of 36 Rossproject: Engineering Design Inc DUCK ADDITION by: RR sheet #: location: 942 ALDER STREET, EDMONDS, WA98020 date: 2/20/2018 client: THE LEREN COMPANY job #: 18016 Roofloads Dead Load Sheathing Joist Beam Min. w/ Uplift Roofing 3.00 psf 3.50 psf 3.50 psf 2.00 Psf Sheathing 1.50 1.50 1.50 1.00 Insulation 2.00 2.00 2.00 1.00 Sprinkler Ceiling 2.50 2.50 Lights 0.50 0.50 Trusses 2.00 2.00 Mechanical 1.00 1.00 Misc -050-1 2.00 2.00 Total 7.00 psf 13.00 psf 15.00 psf 6.00 psf Snow Load Ground Snow Load Pg = Pg = 20 psf Minimum Roof Snow Load = 25 psf Exposure Factor Ce = Ce = 1.0 Thermal Factor Ct = Ct = 1.0 Slope Factor Cs = Cs = 1.0 0.7CeCtCslsPg Design Roof Snow Load Ps = Ps = 14 psf = 25 psf minumum roof snow load controls Wood Floor Loads Dead Loads Sheathing Joist Beam Floor Covering 2.50 psf 2.50 psf 2.50 psf Gyperete Sheathing 2.30 2.30 2.30 Insulation Sprinkler Ceiling 2.50 2.50 Lights 0.50 0.50 Joist 2.00 Mechanical 1.00 1.00 Misc 1.00 1.20 1.20 Total 5.80 psf 10.00 psf 12.00 psf Live Loads Residential 1 40 jpsf Page 5 of 36 Ross Engineering Design Inc project: DUECK ADDITION by: RR sheet #: location: 942 ALDER STREET, EDMONDS, WA 98020 date: 2/20/2018 client: THE LEREN COMPANY job M 18016 Wood Wall Weights Level 2 Exterior Height : 8.00 ft Weight s Cover/Veneer: siding 2.0 Plywood Shtg: 1/2" 1.5 Studs: 2x6 @ 16" oc 1.7 Insulation : fiberglass 1.0 Gwb : 5/8" 2.8 Misc : 1.0 10.0 psf x Height = 80.0 plf Level Interior Height: 8.00 ft Average wall spacing : 7 Ift Weight s Cover/Veneer: Plywood Shtg: Studs: 2x4 @ 16" oc 1.3 Insulation Gwb : /8" both sides 5.5 Misc : 2.0 8.8 psf x Height = 70.0 plf divided by Tributary Width = 1 30.0 psf Exterior Height : 9.00 ft Weight s Cover/Veneer: siding 2.0 Plywood Shtg : 1/2" 1.5 Studs: 2x6 @ 16" oc 1.7 Insulation : fiberglass 1.0 Gwb : 5/8" 2.8 Misc : 1.0 10.0 psf x Height = 90.0_plf_ Interior Height: 9.00 ft Average wall spacing: 7 ft Weight s Cover/Veneer: Plywood Shtg : Studs: 2x4 @ 16" oc 1.3 Insulation: Gwb : 5/8" both sides 5.5 Misc : 2.0 8.8 psf x Height = 78.8 plf divided by Tributary Width = 11.3 psf Page 6 of 36 Rossproject: Engineering Design Inc DUECK ADDITION by: RR sheet #: location: 942 ALDER STREET, EDMONDS, WA 98020 date: 2/20/2018 client: THE LEREN COMPANY job p: 18016 ASCE 7-10 Seismic Design Parameters Risk Category: II IBC Table 1604.5 Importance Factors ASCE Table 1.5-2 Seismic, IE = 1.00 hftp://earthquake.usgs.gov/designmaps/us/application.php Site Soil Class: ASCE Table 20.3-1 Or Geotechical Response Accelerations: For Lattitude = 47.81 degrees Recommendation & Longitude = -122.37 degrees Mapped spectral response acceleration SS= 1.27 g site -specific S1= 0.497 g site -specific Fa= 1.00 IBC Table 1613.3.3(1) Fv = 1.50 IBC Table 1613.3.3(2) Maximum spectral response acceleration IBC 1613.3.3 SMs = FA = 1.27 g Sm, = FvS1 = 0.747 g Design spectral response acceleration IBC 1613.3.4 SDs = (2/3) SMs = 0.847 g SE), = (2/3) SM, = 0.498 g Seismic Design Category: Based on SDs = D IBC Table 1613.3.5(1) Based on SDl = D 1BC Table 1613.3.5(2) Controlling Category = D Building Period: Structure Type = 4 1- Steel moment resisting frame ASCE 12.8.2.1 Building Height h = 18 ft 2 - Concrete moment reisisting frame Ct = 0.02 3 - Eccentrically braced steel frame x = 0.75 4 - All other structural systems Approximate fundamental period Ta =.Ct x h" = 0.17 seconds Response Coefficient: R = 6.50 ASCE Table 12.2-1 W o = 3.00 Cs = SDs/(R/IE) = 0.130 ASCE 12.8.1.1 Cs(max) = SM/(11Ta/10 = 0.438 Cs(mm) = 0.010 Controlling Cs = 0.130 Seismic Design Force: V = CsW = 0.130 W (ult) ASCE 12.8.1 V = CsW/1.4 = 0.093 W (asd ) rho Base Shear= 6T3 Kips 2/20/2018 Page 7 of 36 Ross Engineering Design Inc project: DUECKADDITION by: RR sheet#: location: 942 ALDER STREET, EDMONDS, WA 98020 date: 2/20/2018 client: THE LEREN COMPANY job #: 18016 ASCE 7-10 Wind Design Parameters Risk Category II IBC Table 1604.5 Design Wind Speed V 110 mph Figure 26.5-1 Exposure Category B Section 26.7 Enclosure Classification Enclosed Section 26.10 K,t Topographic Factor 1.0 Figure 26.8-1 Kd Directionality Factor 0.85 (Building CC) Table 26.6-1 Hurricane Region w/ V > 100 mph? No Wind Loads, Components and Cladding ASCE 7-10 Section 30.4, h<60ft; Height h, z 18 ft Roof Slope = 23 Degrees Slope Reduction Factor = 1 Applied to GCp; Velocity Pressure Coefficient Table 30.3-1 a 7 z 30 zg 1200 Kh,z = 2.01(z/zg)2/a = 0.70 Velocity Pressure Equation 30.3-1 qz,h = 0.0026KzKztKdV2 = 18.4 psf GCp; Internal Pressure Coeffecient 0.18 +/- Table 26.11-1 Design Wind Pressure: p = gz,h(GCp- GCp;) psf Figure 30.4-1, Equation 30.4-1 Zone 4, 5 Zone 4 Zone 5 Zone 4,5 Zone 4 Zone 5 Area Gcpi (+) Gcpi (-) Gcpi (-) p inward p outward p outward 10 1.000 -1.100 -1.400 k 21.8 -23.6 -29.1 20 0.947 -1.047 -1.294 # 20.8 -22.6 -27.2 ) 50 0.877 -0.977 -1.153 19.5 -21.3 -24.6 100 0.823 -0.923 -1.047 ) 18.5 -20.4 -22.6 150 0.792 -0.892 -0.985 I 17.9 -19.8 -21.5 200 0.770 -0.870 -0.941 17.5 -19.4 -20.7 300 0.739 -0.839 -0.878 j 17.0 -18.8 -19.5 500 0.700 -0.800 -0.800 16.2 -18.1 -18.1 ) Page 8 of 36 Rossproject: DUECK ADDITION by: RR sheet #: Engineering location: 942 ALDER STREET, EDMONDS, WA 98020 date: 2/20/2018 Design client: THE LEREN COMPANY job #: 18016 Inc Gravity Design Page 9 of 36 Page 10 of 36 1 �m� Z J54 P1_1-1 0 P3_L1 P22_L1 H1 - :. H2 P5_L1 B8/ J70 P4 L1 J69 J68 J67 P1 L1 P„_L1 - B5- ■ B6- J71 J87 P2 L1 I B12" . J86 J85 J101 ' B143 J84 - - J1o0 1 J99 ..... J83 \ m - ro J82. J98 J81 J97 B57 J96 J79 . P9_L1 J95 P8_L1-- P7 L1 - B10f B9 \gyp m m n m m N M N . _ N N . ..... m O N N m m - P12_L1 P13_L1 P1 Lt P2 _L1 P, L1 P16 L, H _. N m m m m m m n r n n m N m m m -- P17_L1 - P18_L1 P19_L1 Loads: DL PreComp - PreCompos@e Dead Load - - Results for LC 1. ASCE 2.4.1-1 UPPER FLOOR Feb 20, 2018 at 7:37 PM KEY PLAN DUECK ADDITIONA Page 11 of 36 Page 13 of 36 Company Feb 20, 2018 _ RASA Designer hPM Job Checked Number Checked By. A NEMETSCHEK COMPANY Model Name Floors Label.. Elevat..Area L... Floor T... _- Deck Default De_ckA.. Parent- Des...Bot :..Con_ Top Re-barAnacti..S L..Spli. No ... Para.., 1 IFOUNDA.� .67 ;None e•T None r 0 7 None N!A N/A N/A .67 sj:; T 0 2 GARAGE � 2 - None Floor B.. --�-- None ....--- - 0 None N/A,N/A' -- - ----- - N/A - --- -i� .1.33S�••, 0 3 UPPER F..; 11.5 ,Reside...Floor B..{Wood FloorDeckt O None ;N/AWN N/A Jr 9.5ashe..l 0 r4 ^ROOF . 19.5 Snow ,Floor-BB.,Wood Trussed R.... 0 _None _N/A N/A _ N/A 8 She..-, 0 Wood Material Properties IaW_ Tvna natnhaca Snar:iac rrarla Cm Fmrrt Nii Tharm r)ancrk/f 1 DF#1 Sdid Sa.. Visually Graded Douglas Fir -Larch No.1 1 .3 .3 .035 2 DF#2 'Solid Sa.. Visually Graded Douglas Fir -Larch No.2 1 _ .3 .3 .035� 3 HF#2 SolidSa.. Visually Graded Hem -Fir L No.2 J 1 J .3 ! .3 .035 I 4 HF STUD SolidSa... Visuall Graded Hem -Fir Stud 1 .3 3 035 5 24F-1.8E D.J.Glulami NDS Table 5A 24F-1.8E DF BAL ' na 1 .3 .3 ' 30 5 6 7 24F-'L8E �...Glulam. 'KING BEAM Custom NDS Table 5A N/A 24F-1.8E DF UNBALI King Beam na ! na 1 1 3 .3 3 .3 .035 T .035 8 VERSA -LAM! SCL Boise Cascade 2.0E-3100F VERSALAM ; na 1 .3 .3 .035 9 PT lCustom N/A PT na 1 .3 .3 1 .035 10 PARALLAM SCL TrusJoist 2.0E DF Parallam PSL na 1 .3 .3 7 .035 11 LVL ! SCL ( TrusJoist_ 1 1.9E TimberStrand LSL ( na l j 1 .3 L- .3 1 .035_ Custom Wood Properties Label Fh rknil Ft rknil Fv rksl Fr fksil F Iknil FnS Iksil Tvne rF 1 LVL_PRL 1.5... 2.25 i 1.5 .22 1.95 T 1500 1005 T sCL r - 2 LVL PRL 2.0... 2.9 1.9 .285 2.75 2000 1340 SCL 3 LV1 L Microllam- 2.6 1 1.555 .285 2.51 1900 1 1273 SCL 4 :PSL Parallam... 2.9 2.025 .29 2.9 2000 1340 SCL 5 PSL Parallam..., 2.4 1.755 .18 2.5 1800 1206 SCL 6 LSL TimberStr... 2.325 1.07 .31 2.05 1550 1038.5 SCL 7 LSL TimberStr... 1.7 1.075 .4 1.4 1300 871 SCL ' 8 f 9 King Beam PT _-- - 3 �- --.68 . - -- 2 _42 .3 _116 _ _ _i 1.8 .832 2300 i 1112 i 1541 745.04 visually... iVisualy .. -- Deck General Provertfes Label _ Material Type _ Deck ___ _ .. .Unbracedifll Max Spa._, 1 Wood Roof Deck Wood Deck .5 in 50 50 T2 Wood Floor Deck Wood Deck .8 in 50 50 _ 3 T Wood Exterior Deckiag Wood Deck _ 1.5 in _ ' 50 _ 50 4 Wood Trussed Roof Wood Deck .5 in 50 50 5- -- - None - _ Wood Deck 0 in - �- 50 Deck Loads _ Label _ Two W ay _-Self Wt [ksf]_ Super DL[ksq Const DLIks�t Const LL [ksfj_ _ 1 Wood Roof Deck .001 .012 r 0 0 2 Wood Floor Deck .002 .009 0 0 3 Wood Exterior Decking .004 1 .001 1 0 0 4 Wood Trussed Roof .001 .014 0 0 5 l - None. .. - - --- - l -. 0 2.917e-6 1-- -Q- -- - _I 0 - RISAFloor Version 12.0.1 [C:\... \...\...\...\...\18016 DueckAddition_LCI\CALCS\DUECKADDITION. rfq Pagel Page 14 of 36 Company RISA Designer Job Number A NEMETSCHEK COMPANY Model Name Feb 20, 2018 7:52 PM Checked By._ Design Deflection Parameters Label DL Deflj...DL Ratio LL Doli...LL Ratio DL+LL Defl[in]_ DL+LL ... Category .Defl[in]_ Ratio Category min] Ratio _ r__ _ r �,.;, • r+ru�nwl nnn n.n 1 1 ••`-•`• uVV NW LTv I VL I I vwv I 1\u11G NW 360 ! _ a. 360 - _---.-.-__-�-240 SL 360 None -- 360 3 2x6 360 ' 360 1240 t SL t 360 None 360 4 2x8 360 360_ 240 SL 360 None 360 5 , 2x10 360 r ' 360 240 _. T SL t 360 T None 360 6 y 2x12 360 360 240 SL None 360 7 4x10-� 360 360 240 SL _360 360 Y None 360 8 HEADER 360 360 240 SL 360 None 360 9 •3x GWLAM 360 360 240 _ SL 360 _ _ _ TNone 360 10 5x GWLAM 360 360 240 SL_ 360 None 360 11 6x GWLAM 360 360 - -' -240 �- SL - --- -- 360 None 360 12 SCL BEAM 360 360 240 SL 360 None 1 360 13 SCL F ULSCL s 360 360 240 SL 360 _ _ ' None R 360 14 TRUSS 1000 1000 1000 SL 1000 None 360 15 ' 1 JOIST 360 _ 480 240 _ ' SL 360 None 360 16 EXIST 1000 1000 1000 SL 1000 None 1 77 14 SCL FL...~-- 360 i -- 360 - - 240 _ fi SL 360 None r 360 18 141JOIST 360 4 - - 1 ;- - i 240 _ SL i 360 None 360 Uniform Area Loads Label... ---_.- ..- r_. Additive.._ „-.PreDL[ksfj_ PostDLjksfj. LL[ksf] LL Type. VL4ksf] Dy_n Laedjksf]_i 1 ' Residential .04 LL-Reduces ; 2 Snow .025 SL 3 -None — - - - - - - - T _ , LL-Non 4 Deck .06 LL-Reduce Line Loads: FOUNDATION Start Point End Point Start Pre... End PreD...Start Post..End Post -Start LL[k..End LL[k/ft] LL Type St Dyn Load [k/... End Dyn Load[_.. No Data to Print -- Line Loads: GARAGE Start Point End Point Start Pre... End PreD... Start Post -End Post -Start LL[k..End LL[k/ft]. LL Type St Dyn Loadjk/...End Dyn Load[_.. — -- -- - No Data to Print ... Line Loads : UPPER FLOOR _Start Point End Point Start Pre... End, PreD... Start Post -End Post..Start LL(k..End LL[klFtj LL Type TSt Dyn Load[k/.�End Dyn Load[ 1 1 i min i N�� T T- T n� T � nT I I -nl„n ; 2 N27 N29 .05 .05 LL-Non 3 N29 N30 .05 .05 LL-Non 4 N30 N 127 .05_ 05 LL-Non 5 N127 _ _ `N125 _ 05 5 LL-Non 6 N125 N129 .05 .05 I LL-Non 7 N129 N128 05 05 LL-Non 8 N128 N14 ! .05 05 LL-Non 9 N14 - - - - _ N12 r .05 1 _ -t - .05 i 1 - - _ _. . LL-Non t RISAFIoor Version 12.0.1 [C:\... \...\...\...\...\18016 DueckAddition_LCI\CALCS\DUECKADDITION. rfq Page 2 Ea6ed lJJ'NOIlIQOVA03n(i\SOl`d0\I0l uoi;ippy�oanO 9L08L\"'\"y"'\'*\"\:0I L'0'ZL uOISJanJOOLAVSlb saA saA SOA SaA Z6' L ("-£'b'ZL 3OS`d ZZ SaA saA saA SOA Z6' L LZ saA saA saA SOX Z6' L £ b'Z L 30Sd OZ j saA saA SaA SOA Z6' L " £'b z L 3 osdi 6 L SaA SOA Salk Salk Z6 L j '-£'b Z L 30SV, 81 SaA saA SaA SOA Z6- L (" E'b'Z L 3 osvi L L I SOA SOA I seA salk 9' L L-L'b Z 3OSV 9 L saA SOA SaA SOA I. 9' L + L-L b Z 3OSVI 9 L I saA SaA saA Salk 9' L - 9-Vt Z 3OSt/ b L SOA SOA -T—SaA saA SOA SaA 9' L 9- L ;+ 8-L b' Z 3 OS`d; E L I �__9-Vb Z 30SV, Z L SGA SaA saA sad SaA Salk 9' L j 9-L'b z 3OSd, L L s L b Z 3 �S d 0 L sa;� saA sa j� 9' l SOA sad SaA �saA SOA SaA 9" L j 9-L�b Z 3osv 6 sa)\ salk 9' L s L b Z 3os`d 8 SaA SaA SaA Salk 9" L j s-L'VZ 3DS`d L saA saA saA Salk 9' L S v b Z 3 oSv�9 SOA saA SaA —saA Salk Salk 9' L s L b Z 3 OSVI 9 saA saA 9 L' L b L b'Z 3 Osv ("b SaA SaA saA SaA I 9 L' L £-L'b Z 30SV £ SaA SaA se)\ Salk Z-L b'Z 30SV I Z saA saA saA Salk L uul{Jduuu-J nJUUW:n d{djuuuj wd WuM WuM wn7j NWJ FOINd {uH vJ!Ndy uJ I SV IWG I U ISaQ UOI)eu!gwoo S'Z- L88' 10 sa)l - 8-E b Z L 3 osv ZZ F—FCIO 9'Z £10 L88- 10 ISa)\ + 8-£'b'ZL 30SV LZ 9L' 1S 91' 11 '_­L- £lol o'n 10 jSakj - 9-£'b'Z L 30SV OZ 9L' 1S 9L' 11 ''81 £10j'01 10 I Sa.l I + 9-£17'ZL 3oSd 6 L S'Z-£10�70 l0 ISOA1 -S-E'bZL3�Sd 8L 9' Z £10' L' l l0 Sa,l + S E'b'Z L 3 0SV 1 L L L- Zl O 9- 10 �� -_ L-L'b'Z 30Sb' 9L L Z10' 9' 10 SaA +L-L'b'Z35Sd 9L (— L- L10 9' 10 sal` - 8-L'17'Z 3 0 SVI b L l no! 9' 10 saA + 8 L b' Z 3 Z)SV I £ L 9L- Z10 9L' IS 9L' 11 L 10 Sa.l -e9-L'b'Z306d ZL �9L' Z10 9L' 1S 9L' 11 L 10 SaA +e9-L'b'Z 30SV L L 9L'- L10 9L' 1S 9C 11 L l0 sa.l - g9-L'b'Z 30SV 0 L 9L' L10 9L' 1S 9L' 11 L 10 Sa,l + g9-L b'Z 3osv 6 L- Zl0 L l0 sa k M- S-L'b Z 3os`d 8 I L Z10 L I 10 Sal, M+9-L'b'Z30Sd, L -- L- L10 L 10 SaA j 3- S -L b Z 3OSV 9 L L10 L 10 Sal. 3+ 9-L b Z 3OSV 9 9L' 1S 9L' 11 L 10 Sal. b L'b'Z 30Sd b L IS L 10 Isar. £-L'b'Z 30SV £ L 11 L 10 Sal. Z-L "b'Z 30Sb z I L I l0 JsOA L-L"b"Z 30SV L W01 Ia:J f401 ia:J +J01 Ia:J fawl +a:J #401 +a:J Wad ia:J ay +WJ 01 401 al +aJ 01 WJ NJ IW.I suoi;euigwoo L. ... Mid of Me(] ON --. I "'TP�I �+� pu3"'�ITPeoI u�a lS ad�l TI Ill��fi Pu3""Mill 1Je1S'_1Sod Pu3 lSod Pels... 4ald Pu3 '**8Jd IRIS lu!od Pu3 lu!od UeIS -4008 : Speo7 aura aweN p POW ANVdW03N3HOS13VQNV A9 PeNoa4o jagwnN gof V.S111 Wd Z9:L lau6isap 8LOZ'OZ g93 Auedwoo 9£ 10 9L a6ed Page 16 of 36 Company Feb 20, 2018 RISA Designer hPM Checked Job Number Checked By. ANEMETSCHEKCOMPANY Model Name Beam Code Summary for Wood: FOUNDATION Label_.. _ _ Size„ Elicit ,Material Bending.._. Loc[ft]-__LC Deft Check Loc[ft]. Cat ShearCh,._Locjit]. --- .... No Data to Print... -- - Beam Code Summary for Wood: GARAGE Label. Size,,. E)911cit Matedal,.Bendir�g.._ _ Loc[ft]_ LC . Defl Check Loc_[ft]_ Cat -Shear Ch-Loc[ft] LC No Data to Print... Beam Code Summary for Wood: UPPER FLOOR Label Size ExMicit Material Bending - Locrftl LC Defl Cher_k Lnciftl Cat Shear Ch.Aacrftl LC 1 H1 ,- 3.5X10.5FS Yes 24F 1.8.. .482 15.042 T 2 .438 1 5.042 rLL .381 0 2 2 1-12 - 3.5X10.5FS ; Yes 24F-1.8... .341 ' 3.719 2 .29 1 4.96 LL ` 447 0 ' 2 3-"1 H3- i 3.125X12FS No 24F-1.8... .746-. 4.896 -r 4 .664 4.8L DL+L648 664 9.792 4 4 -1 B4 2X8 Yes PT .352 4.01 2 .224 5 LL 371 .4.01 2 i 5�e�. B5 3.5xl1.25Fs I No PARAL••. .494 i 5.948 1 2 .487 1 5.948 LL A 0 2 B6 3.5X11.875FS- Yes PARAL-•. .218 1.737 2 .502 11.869 DL+LL! 374 0 2 7 B7 I 5.5X9FS Yes 24F-1.8. .445 5.39 1 2 .755 1 11.499 DL+LL .257 I 0 2 ' 8 B8 3.5x11.25FS . Np ;PARAL..i .161 4.594 ' 2 .154 . 12.25 DL+LL, 10.208 2 9 B9- 3.5x11.25FS No 'PARAL..� 448 T 6.196 2 .466 _ 5.948 LL 332 1�.ase' 2 10 B10 3.5x11.875FS No PARAL••• .538 11.824 4 .806_ 13.354 SL 941 -11.963 4 11,' B11� 125X10.5FS -No 124E-1.8.J .685 T 6.363 2 .813 6.501 LL .402 L0 2 12 - 3.5x11.25FS No PARAL••• .371 11.824 4 .759 13.354 DL+LL y .591 .11•963. 4 _ 13 1 _B12i 1313 15.125X7.5FS No 24 8 .826 4.219 2 T- .866 4.5 + LL ' .585 1 0 2 14 B14 6.125X10.5FS No 24F-1•8.•,. .737 6.38 2 .752 6.125 LL .486 12.25 2 15� B15r 15.25M4FS ° Yes IF1 10.216 3 .899 0 DL+LL .348 12.12 3 16,` 1316- 5.25x11.25FS No PARAL••. .712 T 5_674 3 .878_ 7.565. DL+LL 17 ' B17 3.5x11.25FS No PARAL..� .748 4.721 r 4 r .878 5.283 DL*� L 714 0 4 18 B18 6X12 Yes PT .612 6.713 2 7.323 LL .247_ :14.646 2 19 B19 6X12 Yes r PT .83` 7.39 2 T _348 .478 7.24 LL t .299 t 0 T 2 20 B20 4X8 No PT .156 2.341 2 .055 1.938 LL .142 0 2 21 DJ41 2X8 No PT _ 076 r 10.421 2 .097 11.499 LL .084 _ to.541 _ 2 22 DJ42 2X8_ No PT : 10.421 2 063 ' 11.499 LL 10.541 2 23 DJ43 2X8 _ No _ PT t .047 .058 t 10.421 i 2 . 889 710.421 T LL .053 .065 110.541 2 1 24 DJ44 2X8 No PT .058 10.421 2 .323. 10.421 LL .065 :10.5a1� 2 25 DJ45 2X8 No ' PT .058 + 10.421 T 2 .401 10.421 LL 065 to.541 2 1 26 DJ46 2X8_ r No PT 058 10.421 2 .413 10.421 LL : .065 10.541 2 27 D 47J47J _ 2X8 _ No _ PT 1 .058 i 10.421 2 I .357 j 10.421 LL 1 .065 r•S4 2� 28 ; DJ48 2X8 No PT .058 10.421 2 .24 : 10.421 LL . .065 .10.541 2 29 DJ49_ S `2X8 t No PT .058 10.421 2 .08 10.421 LL 065 10.541 2 30 DJ50_ 2X8 No PT 046 10.421 2 10.421 DL+LL,;_.053 10.541 2 31 - DJ55 2X8 1 Yes PT .049 4.01 2 .C7 569 j 3.958 LL .061 4.01 2 32 ' DJ56 2X8 Yes PT A53 4.01 2 693 3.958 LL 065 :4.01 33 DJ57 2X8 Yes PT _ .053 4.01 fi 2 .697 3.958 LL .065 r4. 1 T 2 34 DJ58 2X8_ Y_es PT 053._ 4.01 2 3.958 LL .065 4.01 2 35 DJ59 _ 2X8 Yes _ PT 185 3.95�8 22 _.589 1 .392 i 3.958 LL 225 5 2 36 DJ60 2X8 Yes PT .156 ; 4.01 2 i 132 3.958 LL .189 4.01 2 37 DJ61 2X8 Yes r PT .283 _ 4.01 2 .187 5 1 LL 1 .34 14.0112 38 J38 2X8 No PT .015 .793 2 .081 .793 DL .043 ' .7931 2 _ 39 ' J39 t 2X8 No PT .01 ' .665 2 .036 0 DL ! .031 0 1 2 40 J40 2X8 ! No PT .01 .665 2 .036 0 DL ; .031 - 0 2 41 J41 2X8 No PT .01 .665 2 .036 0 _ DL I .031 6 t 2 42 , J42 2X8 No PT .01_ .665 2 .036 0_ DL } .031 0. 2 43� J43 2X8 No PT�.01 665 T 2 - _ r .036 0 i-DL_j_,03j_j 0 2 RISAFloor Version 12.0.1 [C:\... \...\...\..A..\18016 Dueck Addition-LCI\CALCS\DUECKADDITION.rfQ Page 4 Page 17 of 36 Company Feb 20, 2018 RASA Designer 7 52 PM Job Number Checked By. ANEMETSCHEK COMPANY Model Name Beam Code Summary for Wood: UPPER FLOOR (Continued) I ahol Riga FYnlirit Mafarial Ranrlinn I ncrffl I C r)efl r.herk I nrfffl r At Shear Ch I nrlffl I(, 44 J44 2X8 No PT .01 .665 2 .036 1 0 DL 1 0 2 45 J45 2X8 _ No _ PT .01 .665 „ 7 2 .036 0 DL _031 031 0 - 2 46 J46 2X8 No PT .01 .665 2 .036 0 DL .03_1_ : 0 2 47 J47 2X8 No PT .003 .393 2 .036 T 0 DL r .018 1.7861. 2 48 J48 2X8 No PT .007 .567 2 .036 0 DL .027_ 0 2. 4 J9 49 2X8 No PT .01 .665 ' 2 .036 0 DL r�.031 _ 0 1 2 50 J50 2X8 No PT .01 .665 2 .036 0 DL 031 0 2 51 i J51 2X8 No PT T01 .665 2 .036 0 DL .031 0 2 52 J52 2X8 No PT .01 .665 2 .036 0; DL i 031 0 _ 2 53 J54 2X8 No PT .58 2.656 ' 2 A38 5.795 1 LL 1 .457 13.8031 2 54 J55 2X8 Yes PT .01 2.5 1 036_ 0 DL .009 0 55 DJ62 2X8 Yes PT .009 2.5 3 0 DL T . 009 0 r _1 1 56 DJ63 2X8 No PT 0 .5 1 .036 DL '. .002 0 1 57 Y _ 657 r3.5x11.25FS Np PgRgL..I _ _ 537 8.395 _ _ 17 _ r .099 _0 13.896 LL I 33 12.014: 17 58 DJ120 2X10 No PT. .157 3 2 3 .125 6 2 59 DJ 221 T 2X10 a No PT .157 _ 3 2 _05 _ .05 _LL 3 1I LL 125 0 2 , 60 DJ164_ 2X10_ No PT .271_ 3_ 2 .103 3 LL 1 .246 ! 6 2 61 r ._ _i DJ165 r 2X10 NO _ r PT .278 3 2 .106 3 LL .253 6 2 62 DJ166 2X10 No PT .278 3 2 3 LL 253 6 2 63 DJ167 2X10 No J PT .2781 3 2 _106 .106 3 LL .253 1 6 i 2 64 DJ168 2X10 No PT 278 3 2 10 3 LL .253.6 6 i 2 65 DJ169� 2X10 No ' PT .278 T 3 T 2 l .106 3 LL t .253 6 2 66 DJ170 1 2X10 No PT .278 3 2 .106 3 LL .253 6_ 2 67 DJ171 2X10 No PT 278 3 - 2 _ .166 _ 3 r LL .253 6 t 2 68 DJ172 2X10 No PT .278 3 2 .106 3 LL .253 ' 6 2 69 DJ173 2X10 No PT ' .27 _ 3 T 2 ' 103_ 3 LL + .249 _T 0 T 2 70 DJ174 2X10 No PT .121 2 2 .036 0 DL .t. .168 4 t 2 71 DJ175 2X10 No PT .121 2 2 .0-3 6 0 DL .168_0 2 /Z UJl/b ZAIU NO l"I AZl Z Z UJO U UL AWS I 4_ Z 1 _ = T 73 DJ177 2X10 No PT 1 .121 1 2 2 1 .036 0 DL .168 4 2 74 DJ178 2X10 2X10 t No No PT PT 1 .121 .121 2 2 2 2 - .036 .036 0 • 0 DL DL .168 .168 4 4 2 2 75 DJ179 76 DJ180 2X10 No PT .121 2 2 .036 DL .168 4 2 _ 77 DJ181 r 2X10 No� y PT .121 2 2 .036 r _ _0......_... 0 DL� 168 42 78 DJ182 _ ._ 2X10 No PT _ .121 T2 . 2 . .036__ _ 0 DL .168_ 0 79 DJ183 2X10 No PT 277 3 2 .105 9 LL 262 0 _2� 2 80 DJ184 �2X10 No PT P/u .271 3 _ ' 2 .103 3 LL .246 • 6 ' 81 B143 i5.25x11.25F� No •i 032 11.869 r 3..� _255 1 11.869 o�+LL . _ .039�2.014 3 Beam Code Summary for Wood: ROOF Label Size Explicit 7Material Bending ... Loc_jftj LC . Drell Check L_o_c[ft] Cat _ ShearC_h...Loc[it] LC 1 T H1 4X8 I No ; DF#2' Al2 r 1-344 3 036 T 0 DL T 018TO0 i 3 ' 2 H2 4X8 No DF#2: .068 3.156 3 .036 0 DL 3 ' H3 _ 4X8 No D #F 2 .012 _ 1.318 1 3 T .036 - 0 -_..�. DL .0171 0 3 4 H4 4X8 No DF#2 .221 2.125 3 .065 2.125 .DL+LU .203 4.25 ! 3 5 H5 4X8 No DF#2 .09 3.625 3 .045 3.625 'DL+LL: .048 ; -' 3 6 H6 4X8 No DF#2 .047 2.625 3 036 0 DL ; .035 0 3 7 ! H7 =4X8 I No I DF#2 .031 2.125 A36 0 DL 028 01 3 8 H8 4X8 No DF#2 .018 1.625 3 .036 0 DL .022 0 : 3 9 j H9 j 3.1Z5X12FS j No 1zaF-1.s..j .742 1 6.375 3 i .692 1 6.375 jM+LLIl .503 j 0 3 Page 18 of 36 Company Feb 20, 2018 I Designer PM - RISA Job Number Checked By. ke Checked A NEMETSCHEK COMPANY Model Name Wood Column Code Checks Stack Lift Shape, „Code C... Elev[f9 LC Shear C... Elev[f1] Dirr LC [ksi] ,Ft' jksi],-;Fb1',[ksi Fb2 ksi , E�cn r1 P1 1 2-2X4 .620 2 2 .000 2 rFc' z ' 22 .384 ? .788 rFv_'.jks].7 1.268 1.403 15 3.6.3 ' 2 P2 ' 1 3-2X4 .801 2 2 .000 2 z 22 .428 863 1.347 ' 1.485 .18 3.6.3 3 P3 1- r ' 2-2X4 ? Y- .350 2 - - 2 .000 2 z 22 384 =-r 788 t r 1.268 1.403 ' '- .15 1 3.6.3 4 P4 1 ; 3-2X4 .756 2 4 000 2 z 122 .366 1 .906 1.462 • 1.613 .172 3.6.3 5 ; _ P5 1 i 2-2X4 .543 1 2 00 2 i z ; 22 .397 T1.512 �2 42 12.693 .288 T 3.6.3 f F PR i :: 1-9,xa TRF 9, a nnn 9 7 99 . aRa aa? 1 Raa 1 7nR �m R 7 - P7 1 ,- 4-2X4 .722 2 120 .000 i 2 1z 122 1 .486 1 1.656 1 2.586 12.851 1 .346 3.6.3 8 P8 1 4-2X4 .755 2 2 .000 2 z 22 .465 .863 1.349 1.485 .18 3.6.3 9 P9 11 1 5-2X4 .970 2 119 .000 2 z 22 I .486 1 1.656 ' 2.589 ' 2.851 .346 3.6.3 10 11 P10 P11 1 1 2-2X4 6X6 .762 .531 _ 2 2 2 2 4.000.. .000 2 _ z 22 2 z 22 .384 54 788 5 1.268 .75 1.403 .75 .15 17 3.6.3 3.6.3 12 13 P12 1 6X6 P13 :11 4X6 ! .322 .840 2 _� 2 3 2 .000 000 ' 2 z 22 ! 2 z 22 T .589 1 .483 288 I .546 .782 .88 .782 .928 _ 133 3.6.3 .116 3.6.3 14 P14 1 . 6X6 .502 , 2 2 000 2 z 22 .555 42_ .68 .68 .116 3.6.3 15 P15 11 6X6 380 23 .000-2- +z 22 .589 4 3� .782 .7821 .133 1 3.6.3 16 P16 .1 4X4 .124 2 2 .000 2 z 22. .29 .63 1.02 1.02 .116 3.6.3., 17 P17 1 6X6 .099 2 2 1 .000 1 2 1z 1221 .555 .42 .68 ' .68 .116 3.6.3 ; 18 19 T P18 .._� P19 1 6X6 _� 1 6X6 .163 .082 2 2 2 2 .000 .000 • 2 z 22 i 2 z : 22 .555 _� .555 ' .42 .42 -.-.68 .68 .68 .: .68 _116 .116 3.6.3 13.6.3 20 21 P20 P21 1 4X6 1 3-2X4 � .724 .896 2 2 2 000 _ 4 T .000 2 2 �z ' 22 ' z ! 22 .288 _ .439 .546 992 .88 ° .928 _.1_16 _.3fi- � _ ._ _._ T 1.549 ! 1.708 .207 t 3.6.3 22 P22 : 1 2-2X4 086 2 2 .000 1 2 z ` 22 .465 .863 1.344 1.485 .18 3.6.3 23 = P23 1 2-2X6 .330 3 1 .000 111.5 1 z 122 ' .708 ' .46 .773 I .893 .172 13.6.3 24 25 P24 1 : 2-2X6 P25 ' 1 2-2X6 .330 ; .021 11_5 11.5 3 3 000 0 . 11.5 z 22 11.5 ' z _ 22 r .708 .708 _46 46 .773 Y .893 T .773 .893 .172 .172 3.6.3 3.6.3 26 P26 1 2-2X6 .021 11.5 3 .000 11.5 z 22 .708 .46 .773 .893 .172 3.6.3 Wall Results, Wood Wall Panel Wall Pnncl Pc inn Stun RI7P Rturi Rnarinnfinl Avini Chork i,rw 1 R 1 r W44A R1 2X4 16 .298 2 2 _j W45 R1 2X4 _ 16 .233 2 3 W46 R1 2X4 _ 16 .397 4 4 W47 R1 2X4 16 .832 ! 19 5 W48 _ R1 7 2X4 t IT 16 ....... .... ......_......_....306 _ 3 6_ W49 R1 2X4 16 17 7 r W50 - R1 _ - _ _ - -�- 2X6 -- _.. 16 i _..021 _ .099 f 2 ----- 8 W51 R1 2X6 16 .117 2 9 W55 R1 2X6 16 .016 _ 3 - 10 W56 2X6 16 .015 3 11 -- W57 �- -R1 R1 . 2X6 -. T - - --, -- ...._ 16 ._. .084 3 12 W58 R1 2X6 16 ! 3 13 ' _ W59 �- R1 2X6 16 _102 _. T .021 3 14 W60 R1 _ 2X6 7 16 .021 15 W61 R1 2X6 16 .109 3 16 W62 R1 2X6 16 .011 3 1- W63 R1 2X6 16 .121 3 18 W64 R1 2X6 16 .02 3 19 _ W65 R1 2X6 16 .02 _ 3 26 W66 R1 2X6 16 .054 3 21. W67 _ i R1 2X6 16 3 22 _ W68 _ R1 i 2X6 --16 1 - - .016 _ A27 _ _ 3 RISAFIoor Version 12.0.1 [CA...\...\...\...\...\18016 Dueck Addition_LCI\CALCS\DUECKADDITION.rff Page 6 Page 19 of 36 Company ' Designer RISA Job Number ANEMETSCHEK COMPANY Model Name Wall Results, Wood Wall Panel (Continued) Feb 20, 2018 7:52 PM Checked By. Wall Panel Region Size_ Stud Spacing[in].. Abal Check_ Gov LC _ ___ r 23 W69 R1 _Stud 2X6 ___ -_-� 16 -.015 _ 3 24 W70 l R1 2X6 16 .117 3 25 ( W71 I R1 2X6 16 .122 3 27 -- W73 -- R1 2X6 1_ _16 _ _ _ -1 _ .077 ._ _.�. - - Page 20 of 36 Rossproject: Engineering Design Inc DUECK ADDITION by: RR sheet #: location: 942 ALDER STREET, EDMONDS, WA 98020 date: 2/20/2018 client: THE LEREN COMPANY job #: 18016 Footings Allowable Bearing = 2000 Wall St Loc [ft) End Loc [ft] Length [ft] psf Max Base Reaction[k) Label Top Floor Bottom Floor Start Point End Point Material Type Material Set Footing Width (in) Result (psf) Check F1 9.826,49.96 1L826,49.96 2.0 3.55 F1 FOUNDATION Base N1 N2 Concrete Conc3000NV) 24 888 OK F2 19.909,49.96. 21.909,4996 2.0 5.98 F2 FOUNDATION Base N3 N4 Concrete COnc3000NN 24 1495 OK F3 29.826,49.96 31.826,49.96 2.0 2.60 F3 FOUNDATION Base N5 N6 Concrete Conc3000Nv1 24 649 OK F4 - 32.659,46.96 32.659,44.96 2.0 2.79 F4 FOUNDATION Base N7 N8 Concrete Conc3000N1A 24 697 OK FS 32.659,44.106 32.659,42.106 2.0 5.95 FS FOUNDATION Base N9 N10 Concrete Conc3000MA 24 1488 OK F6 32.659,34.314 32.659,32.314 2.0 7.03 F6 FOUNDATION Base N11 N12 Concrete Conc3000NN 24 1758 OK F7 33.659,26A6 31.659,26.46 2.0 7.65 F7 FOUNDATION Base N14 N15 Concrete Conc30DOW 24 1913 OK F8 21.763,26.46 19.763,26.46 2.5 9.17 F8 FOUNDATION Base N16 N17 Concrete COnc3000NN 30 1467 OK F9 9.868,26.46 7.868,26.46 2.5 12.50 F9 FOUNDATION Base N18 N19 Concrete Cono3000NNI 30 2000 OK F11 19.763,39.46121.763,39.461 2.5 9.96 F11 - FOUNDATION Base N22 N23 Concrete Cone3000NN 30 1593 'OK F12 35.534,9.955 37.534,9.955 2.0 1.02 F12 FOUNDATION Base N24 N25 Concrete Conc3000NN 24 256 OK F13 6.409,3.955 8.409,3.955. 2.0 2.21 F13 FOUNDATION Base N26 N27 Concrete Conc3DODNVI 24 554 OK F14 20.888,3.955 22.888,3.955 2.0 3.25 F14 FOUNDATION Base N28 N29 Concrete Conc3000N1A 24. 812 OK F15 35.534,3.955 37.534,3.955 2.0 1.92 F15 FOUNDATION Base N30 N31 Concrete Conc3000N%A 24 479 OK F16 6.409,9.95S 33.659,9.955 27.3 34.77 F16 FOUNDATION Base N32 N33 Concrete Conc3000N1n 16 9S7 OK EX F17 - 31.826,49.96 32.659,49.96 0.8 0.57 EX F17 FOUNDATION Base N6 N34 Concrete Conc3000NN .12 683 OK EX F18 32.659,49.96 32.659,46.96 3.0 0.79 EX F18 FOUNDATION Base N34 N7 Concrete Conc3000N1A 12 263 OK EX F20 8.868,49.96 9.826,49.96 1.0 0.73 EX F20 FOUNDATION Base N35 N1 Concrete Conc3000NN 12 764 OK F43 8.868,37.252 8.868,39.461 2.5 9.75 F43 FOUNDATION Base N36 N37 Concrete Conc3000NN 24 1949 OK EX F41 8.869,39.461 8.868,49.96 10.5 3.87 EX.F41 FOUNDATION Base N37 N35 Concrete .. Conc3000NIA 12 369 OK EX F52 32.659,44.96 32.659,44.106 0.9 1.17 EX F52. FOUNDATION Base N8 . N9 Concrete :. Conc3000NV) 12 1367 OK EX F53 32.659,42.306 32.659,34.314 7.8 1.51 EX F53 FOUNDATION Base N10 N11 Concrete Conc3000Nt4 12 194 OK EX F54 32.659,32.314 32.659,26.46 5.9 6.94 EX F54 FOUNDATION Base N12 N38 Concrete Conc3000NO[ 12 1185 OK Page 21 of 36 Rossproject: DUECK ADDITION b RR sheet #: Engineering location: 942 ALDER STREET, EDMONDS, WA 98020 date: 2/20/2018 Design client: THE LEREN COMPANY job #: 18016 Inc Lateral Design Page 22 of 36 Ross Engineering Design Inc roject:: DUECKADDITION by: RR sheet#: location: 942 ALDER STREET, EDMONDS, WA 98020 date: 2/20/2018 client: THE LEREN COMPANY job #: 18016 Seismic Story Shear Story Weights Level 2 Level 1 Weight Area / Length Total Weight Roof 15.0 psf 820 sq ft 12.3 Exterior Wall Above 0.0 plf 0 ft 0.0 Exterior Wall 40.0 plf 130 ft 5.2 Interior Wall Above 0.0 psf 0 sq ft 0.0 Interior Wall 5.0 psf 820 sq ft 4.1 Low Roof 0.0 psf 0 sq ft 0.0 Other i ( psf ) sq ft 0.0 Floor 12.0 psf 820 sq ft 21.6 i k 9.8 Exterior Wall Above 40 plf 130 ft 5.2 Exterior Wall 45 plf 94.5 ft 4:3 Interior Wall Above 5.0 psf 820 sq ft 4.1 Interior Wall 5.6 psf 0 sq ft 0.0 Low Roof 15.0 psf 200 sq ft 3.0 nrhor t 1-f I-ft nn Story Shear C, = 0.130 (ult ) Height Weight V. Level hx (ft) wx (k) hxwx Fx (k) ) ( 2 18.00 21.6 389 ) 3.88 1 9.00 26.4 238 ) 2.37 1 Total = 48.0 626 6.25 Mora, = cs x Swx = : - 6.25 k Fx = Vwtai x hxwx / Shxwx Diaphragm Shear SDs = 0.847 I E = 1.00 Weight Story Shear Level wi(k) Sw, F,(k) SF, 2 21.6 21.6 3.88 3.88 1 26.4 48.0 2.37 6.25 Max Fpx=0.40xlpxSpsxW;= 0.34 xw; Min Fpx=0.20xlpx5DSxW; = 0.17 x w; Base Shear V =1 6.25 k Dia. Shear Fpx(k) Max Fpx (k) Min Fpx (k) Controlling Fpx(M ) 3.88. 7.32 3.66 3.88 3.44 8.94 4.47 ( 4.47 Page 23 of 36 Rossproject: Engineering Design Inc DUECK ADDITION by: RR sheet#: location: 942 ALDER STREET, EDMONDS, WA98020 date: 2/20/2018 client: THE LEREN COMPANY job #: 18016 Wind Loads Main Wind Force Resisting System ASCE 7-10 - Method 2 per Figure 28.6-1 Wind Criteria Risk Category: II Wind, IW = 1.00 Hurricane Region w/ V > 100 mph? No I = 1.00 Basic Wind Speed (V) (ult) = 110 mph K,t = 1.00 Exposure = B Roof Angle = 23 deg Average Roof Height = 21 ft Plate Height (H) = 18 ft Least Horiz Dimension (L) = 23.5 ft 0.10L = 2.35 ft 0.4(H) 5 ft amin = max of3ftor0.04L= 3 ft a= 3 ft 2a = . 6.0 ft Simplified Design Wind Pressure Load Case 1 Load Case 2 IMinimurn Controlling Zone PM(PSO PI(Ps11 P00(0f) Ps(Psf) Ps (PA P:(Psf) A 26.6 26.6 0.0 0.0 16.0 26.6 B -7.0 -7.0 0.0 0.0 8.0 8.0 C 17.7 17.7 0.0 0.0 16.0 17.7 D -3.9 -3.9 0.0 0.0 8.0 8.0 E -23.1 -23.1 0.0 0.0 --- F -16.0 -16.0 0.0 0.0 --- -- G -16.0 -16.0 0.0 0.0 --- ---- H -12.2 -12.2 0.0 0.0 --- ---- EON -32.3 -32.3 0.0 0.0 --- ---- GoH -25.3. -25.3 0.0 0.0 --- ---- Transverse v 2/20/2018 Page 24 of 36 Rossproject: Engineering Design Inc DUECKADDITION by: RR sheet location: 942 ALDER STREET, EDMONDS, WA98020 date: 2/20/2018 client: THE LEREN COMPANY job #: 18016 Wind Story Shear Front to Back Zone A Zone B Zone C Zone D 26.6 Ps(Psf) 8 Ps(Psf) 17.7 Ps(Psf) 8 P:(Psf) Level Area (ft2) Area (ft2) Area (ft2) Area (ft2) VW (K) 2 66 129 4. 44 1 104 120 4.89 t Side to Side Zone A Zone B Zone C Zone D 26.6 Ps(Psf) 8 Ps(Psf) 17.7 Ps(Psf) 8 Ps(Psf) Level Area (ft2) Area (ft2) Area (ft2) Area (ft2) Vw (K) 2 36 62 80 184 4.34 1 117 191 6.49 2/20/2018 Page 25 of 36 Ross Engineering Design Inc project: DUECK ADDITION by: RR sheet#: location: 942 ALDER STREET, EDMONDS, WA 98020 date: 2/20/2018 client: THE LEREN COMPANY job M 18016 Story Shear Summary Front to Back Seismic Wind Level VE (K) VW (K) 2 3.88 4.04 1 2.37 4.89 Side to Side Seismic Wind Level VE (K) VW (K) 2 3.88 4.34 1 2.37 6.49 2/20/2018 Page 26 of 36 Ross Engineering Design Inc project: DUECK ADDITION by: RR sheet #: location: 942 ALDER STREET, EDMONDS, WA 98020 date: 2/20/2018 client: THE LEREN COMPANY job #: 18016 Roof Diaphragm and Chord Design Unblocked Diaphragm Allowable Shear per NDS Table 4.2B (asd) G r 0.43 SGAF = [1-(0.5-G)] Sheathing Grade Common Nail Size Minimum Fastener Penetration into Framing Mimimum Nominal Panel Thickness Minimal Nominal Framing Width V Seismic V Wind plf plf Case 1 Case 2, 3, 4, 5, 6 Case 1 Case 2, 3, 4, 5, 6 Struct I 6d 1-1/4 5/16 2 153 116 214 163 3 1 172 130 242 181 8d 1-3/8 3/8 2 223 167 312 235 3 246 186 344 260 Sod 1-1/2 15/32 2 265 200 372 279 3 298 223 416 312 Sheathing and Single Floor 6d 1-1/4 5/16 2 140 102 195 144 3 158 116 221 163 3/8 2 153 116 214 163 3 172 130 242 181 8d 1-3/8 3/8 2 200 149 279 209 3 223 167 312 235 7/16 2 214 158 300 221 3 237 177 332 246 15/32 2 223 167 312 235 3 246 186 344 260 10d 1-1/2 15/32 2 237 177 332 246 3 270 200 377 279 19/32 2 265 200 372 279 3 298 1 223 416 312 Check Roof Diaphragm Front to Back Case 2 Suport Perpendicular to Shear V (ult) Dia. D v (asd) (k) (ft) (plf) Seismic 3.88 27.0 s0 < 177 OK Wind 4.04 45 < 246 OK Side to Side Case 2 Suport Perpendicular to Shear V (ult) Dia. D v (asd) (k) (ft) (plf) Seismic 3.88 38.0 36 < 177 OK Wind 4.34 34 < 246 OK Check Tyical Chord For Maximum Force Vmax (ult) = 2.72 k (asd) Diaphragm Width= 38.0 ft Diaphragm Depth = 27.0 ft Plate Size 2x6 Ft alb. = 525 psi Chord Splice Capacity = (16) 16d nails = 16 x 122 lb x 1.6 = M = 12.90 kft T = M/D = 478 lb At = 8.25 Tallow = Ft allow x At x Cd = 6930 Ib > 3123.2 lb>T OK 478 OK Page 27 of 36 Rossproject: Engineering Design Inc DUECKADDITION by: RR sheet#: location: 942 ALDER STREET, EDMONDS, WA 98020 date: 2/20/2018 client: THE LEREN COMPANY job #: 18016::] Wood Shear Wall Schedule NDS Table 4.3A max stud spacing = 16" oc ? yes specific gravity: r 0.43 i specific gravity miltiplier = 0.93 Seismic panel panel fastener nail (common or nail edge spacing grade thickness penetration galvanized box) 6 4 3 2 5/16" 11/4 6d 186 279 363 474 3/8" 13/8 8d 260 400 512 679 C - D (Struct 1) 7/16" 13/8 8d 260 400 512 679 15/32" 13/8 8d 260 400 512 679 11/2 10d 316 474 618 809 3/8 11/4 6d 186 279 363 474 13/8 8d 242 353 456 595 7/16" 138 8d 242 353 456 595 C D 15/32" 138 8d 242 353 456 595 11/2 10d 288 428 558 716 19/32" 11/2 30d 316 474 618 809 Wind panel panel fastener nail (common or nail edge spacing grade thickness penetration galvanized box) 6 4 3 2 5/16" 11/4 6d 260 391 508 664 3/8" 13/8 8d 365 560 716 950 C - D (Struct 1) 7/16" 13/8 8d 365 560 716 950 15/32" 13/8 8d 365 560 716 950 1112 10d 443 664 866 1133 3/8" 1114 6d 260 391 508 664 13/8 8d 339 495 638 833 C-0 7/16" 13/8 8d 339 495 638 833 15/32" 13/8 8d 339 495 638 833 11/2 10d 404 599 781 1003 19/32" 11/2 10d 443 664 866 1133 Sheathing Capacities Shear Wall Panel Panel # of Sides Nail Nail Seismic Wind Label Grade Thickness Sheathed Size Spacing (plf) (plf) 11 C-D 7/16" 1 8d 6 242 339 1 12 C-D 7/16" 1 8d 6 242 339 1 13 C-D 7/16" 1 8d 4 353 495 1 4 C-D 7/16" 1 8d 3 456 638 1 5 C-D 7/16" 1 8d 2 595 833 1 16 C-D 7/16" 2 8d 3 911 1276 1 r r r � r � Page 28 of 36 Rossproject: Engineering Design Inc DUECKADDITION by: RR sheet#: location: 942 ALDER STREET, EDMONDS, WA 98020 date: 2/20/2018 client: THE LEREN COMPANY job #: 18016 Shearwall Connections Shear Clips Simpson Shear Connectors, pg 190 Fastener Allowable Shear (lb) LS50 630 LTP4 575 A34 445 A35 600 16d TOENAIL 75 Sill Plate Connection to Concrete Bolt Side NDS Table 11E Diameter Member Z (lb) Z' (lb) G = 0.43 1/2" 1-1/2" 590 944 CD = 1.6 5/8" 1-1/2" 860 1376 CM = 1.0 3/4" 1-1/2" 1200 1920 1/2" 2-1/2" 730 1168 5/8" 2-1/2" 1070 1712 3/4" 2-1/2" 1400 2240 Sole Plate Connection to Rim/Blocking NDS Table 11J & 11N, ESR-2236 side G = 0.43 Dowel Member Z (lb) Z' (lb) CD = 1.6 16d 1.5 122 195 CM= 1.0 SDSl/4x6 2.5 245 392 Connection Capacities Shear Wall Label Shear Clips Type Spacing Capacity Sill Plate Size Anchor Spacing Capacity Sole Plate Size Dowel Spacing Capacity Controlling Capacity 1 16d TOENAIL 6 1150 2x 5/8" 48 1344 2x 116d 16 1390 150 2 LTP4 24 1288 2x 5/8" 48 1344 2x 116d 16 1390 288 3 LTP4 18 1383 2x 5/8" 32 1516 2x 116d 14 1586 383 j 4 LTP4 14 1493 2x 5/8" 24 1688 2x 116d 14 1586 493 5 LTP4 10 1690 ..2x 5/8" 18 1917 2x 116d 13 1781 690 I 6 LTP4 7 1986 3x 5/8" 18 11141 3x ISDS1/4x6 14 11176 986 Page 29 of 36 Rossproject: Engineering Design Inc DUECK ADDITION by: RR sheet#: location: 942 ALDER STREET EDMONDS WA 98020 date: 2/20/2018 client: THE LEREN COMPANY job #: 18016 Shear Wall Braced Lines Front to Back Tributary (%) Side to Side Tributary {%J Level Level Label GRID A GRID B GRID E GRID F GRID GRID GRID GRID GRID GRID TOTAL SHEARWALL DESIGN 100 100 Label GRID 2 GRID 3 GRID 4 GRID 5 GRID 5.5 GRID 7 GRID 8 GRID GRID GRID TOTAL 100 100 Ve = Accumulated seismic shear on Braced Line (k) ve= Design seismic shear on the design panel (plf) Vw = Accumulated wind shear on Braced Line (k) vw = Design wind shear on the design panel (pin Ltot = Total shear panel length in Braced Line (ft) ve a = Allowable seismic shear of the design panel (plf) H = Plate height (ft) vw a = Allowable wind shear of the design panel (plf) Lsw = Length of design shear panel for overturning (ft) Tr = Tributary roof/floor (ft) L1, 2, 3 = Length of shear panels between openings in a perforated shear wall (ft) La = Adjacent wall length (ft) Hopg = Height of opening in a perforated wall (ft) Ta = Adjacent tributary roof/floor (ft) Co = Reduction factor for a perforated shear wall P1= Design panel weight (lb) Ratio = Height -length aspect ratio of a shear segment P2 = Adjacent wall weight (lb) 2L/H = Aspect ratio reduction factor T = Overturning tension (lb) C = Overturning compression (lb) V 2/20/2018 c- Ross Engineering Design Inc project: DUECK ADDITION by: RR sheet #: location: 942 ALDER STREET, EDMONDS, WA 98020 date: 2/20/2018 client: THE LEREN COMPANY job #: 18016 LEVEL 2 Front to Back Shearwall Design E T/C W T/C GRID Ve Vw Ltot H - - Type Lsw Ll L2 L3 Hopg Co Ratio 2L/H SW ve ve a vw vw a Tr La Ta P1 P2 Above Above E T/C W TIC Holdown A 194 202 014.S=8.00=Seg�577514 1.00 1.39 1.00 0=1=1 94 150 84 150 1112.5t 4t�1 923 228 0 0 60 -21 Iw NOT.REQ'D� E 097 101 JR21=8.00=Seg> 214 1.00 0.38 1.00 MIMI 32 150 29 150 012.5=4�1 3371 228 0 0 -1655 -1682 SNOT REQ'D= F 097 101 I♦1758001Seg�17� 1.00 0.47 1.00 �10i 40 150 36 150 N13.5W41 1� 2882 228 0 0 -1349 -1384 "�NOT REQ'D LEVEL GRID 3.88 2 Ve 4.04 Side to Side Shearwall Design Vw Ltot H Type Lsw Ll L2 L3 Hopg Co -Ratio 2L/H SW ve vea vw vwa Tr La Ta P1 P2 E T/C Above W T/C Above E T/C W TIC Holdown 2 097 109 06=800=Perf1 11�3i3�4=. 080 267 075 $=1" 113 145 109 150 1=11l4�1 627 228 0 0 48 -68 1•NOT REQ'D7 3 0.58 0.65 W4.5=8 00=5eg> 4.591 1.00 1.78 1.00 '"K11( 91 150 87 150 051�4�110 257 228 0 0 368 338 il� NOT REQ'D7� 5 155 1.74 W51 8.00=Seg> 151" - - 1.00 1.60 1.00 0220 217 242 208 288 0011�41 1=j 285 228 0 0 1368 1297 1�MSTC48R3 7 078 087 05135W800=Pert. 12.331=2.6=2:751 4=0 0.77 3.08 0.65 IN 10 102 121 97 150 =11 4t 1"- 703 228 0 0 -227 -241 N�NOTRDXD� Ross project: DUECK ADDITION by: RR sheet #: Engineering location: 942 ALDER STREET, EDMONDS, WA 98020 date: 2/20/2018 Design client: THE LEREN COMPANY job M 18016: Inc LEVEL GRID 1 Ve Front to Back Vw Ltot H Type Shearwall Design Lsw L1 L2 L3 Hopi; Co Ratio 2L/H SW ve vea vw vwa Tr La Ta PI P2 E T/C Above W T/C Above E T/C W T/C .. Holdown B 313 446 12 900 Seg. 12 100 075 100 1 2 1 182 242 223 288 1 1 4 4 L 734 331 0 0 943 1311 1 HDU4 E 313 446 11075 900 Seg. 425 1 100 212 094 1 2 1 204 228 249 288 1 1 4 1 1 260 245 -1655 -1682 -198 185 1 NOT REQ'D LEVEL GRID 6.25 1 Ve 8.93 Side to Side Vw Ltot H Type Shearwall Design Lsw L1 L.2 L3 Hopg Co Ratio 2L/H SW ve vea vw vwa Tr La Ta P1 P2 E T/C Above W T/C Above E T/C W T/C Holdown _ 3 1.56 2.71 1 4 7.00 Seg. 2 1 1.00 3.50 0.57 1 4 1 273 260 406 493 1 1 4 1 1 98 197 368 338 2037 2936 [ STHD14 4 2.50 4.33 1 23 8.00 Seg. 23 1 1 00 0.35 100 1 1 1 76 150. 113 150 1 1 4 1 1. 1270 221 0 0 -247 49 1 NOT REQ'D 1 8 2,19 3.79 1 5 7100 Seg 2.5 1- 100 2.80 0 71 1 4 1 306 326 455 493 1 1 4 1 1 123 197 0 0 1886 2927 1 STH014 1 to 50 0 y4 " 01 D CD W O_ W m Page 32 of 3 Loads: 01-1 - Other Load 1 Results for LC 1, ASCE 2.4.1-1 UPPER FLOOR SEISMIC OVERTURNING Lateral Gravity i Page 33 of 36 x l;T-z Loads: OL2 - Other Load 2 Results for LC 1, ASCE 2.4.1-1 UPPER FLOOR WIND OVERTURNING Feb 20, 2018 at 7:43 PM DUECK ADDITIONA Page 34 of 36 Beam: B57 Shape Group: 2.0E Parallam PSL Code: AWC NDS-12: ASD Floor: UPPER FLOOR Span: Continuous Size: 3.5x11.25FS Fixity: Pinned -Pinned Material: PARALLAM Bending: Strong Axis Function: Gravity Geometry: Length=13.8958ft Points (Start to End): N124 to N127 (20.7634,28.9554,0) to (34.6592,28.9554,0) Angle: 0 degrees Diagrams for Load Combination 22: ASCE 12.4.3-8 - Load Diagram : Distributed Loads (k/ft), Point Loads (k) Envelope and Category Shear Reactions: (k) Non Reducible (Unreduced) Non Reducible (Unreduced) DL LL+LLS LL+LLS Roof ILL Total Roof LL Total I -End: .083 0 .289(b)-.044(a) 0 J-End: Maximum Total I -End Reaction: 2.083k for LC 22 (ASCE 12.4.3-8 -), skip loading case. a Maximum Total J-End Reaction: Cantilevered end. No connection reactions Maximum Total I -End Uplift Reaction: -.658k for LC 21 (ASCE 12.4.3-8 +), skip loading case a Maximum Total J-End Uplift Reaction:-1.462k for LC 22 (ASCE 12.4.3-8 -), skip loading case c Shear: 32.3% Capacity at 12.0141ft for LC 21 (ASCE 12.4.3.8 +) UPLIFT HANDLED 9Y TWIST STRAPS V = 4.724k at 12.0141 ft fv = .1.8ksi Fv' = 0.5568ksi, skip loading case a TO Bil AND HDU4 TO POST AND HOLD-DOWN Wood Shear Factors Fv = .29ksi CD = 1.92 Cm = 1 Ct = 1 Bending: 53.6% Capacity at 8.3954ft for LC 21 (ASCE 12.4.3-8 +), skip loading case a M =-16.968k-ft RB. = 12.3749 le -bend Top = 11.8958ft le -bend Bot = 13.8958ft fb = 2.758ksi Fb' = 5.14588ksi Wood Bending Factors Fb=2.9ksi CD=1.92 Cm=1 Ct=1 Cfu=1 CL=0.924188 CIF =1 Cr=1 CV=1 RISAFloor Version 12.0.1 [CA ... \... \... \... \... \18016 Dueck Addition_LCI\CALCS\DUECK ADDITION.rfl] Page 1 Title Block Line 1 You can change this area using the "Settings" menu item and then using the "Printing 8 Title Block" selection. Beam on Elastic Foundation Description : GRADE BEAM CODE REFERENCES Calculations per ACI 318-11, IBC 2012, CBC 2013, ASCE 7-10 Load Combinations Used : ASCE 7-10 Material Properties Project Title: Page 35 of 36 Engineer: Project ID: Project Descr: fc = 2.50 ksi Phi Values Flexure : 0.90 fr = fc1� ' 7.50 = 375.0 psi Shear: 0.750 yr Density = 145.0 pcf p 1 = 0.850 ` X Lt Wt Factor = 1.0 Elastic Modulus = 3,122.0 ksi Soil Subgrade Modulus = 250.0 psi / (inch deflection) _ Load Combination ASCE 7-10 fy - Main Rebar = 60.0 ksi Fy - Stirrups = 40.0 ksi E - Main Rebar = ),000.0 ksi E - Stirrups = 29,000.0 ksi Stirrup Bar Size # = # 3 Number of Resisting Legs Per Stirrup 2 Beam is supported on an elastic foundation. Printed: 20 FEB 2018. 7:47PM ENERCALC, INC.1983.2014, Build:6.14.3.31, Ver.6.14.3.31 18 in D(2.5) L(Uj.8*.2p ("fQ.E4)2W.8) E(2.9) D(3.1) L(5.6) S(0.63) D(1.3) L(2.4$kZ5jQM64.8JXfPV2".8) E(2.9) I I 18"wx10"h Span=27.0 ft Cross Section & Reinforcing Details Rectangular Section, Width =18.0 in, Height =10.0 in Span #1 Reinforcing.... 244 at 3.0 in from Bottom, from 0.0 to 27.0 ft in this span Applied Loads Beam self weight calculated and added to loads Point Load: D = 2.50, L = 0.30, S = 3.20, W = -4.80, E = -2.90 k @ 1.50 ft Point Load: D=1.440, L = 3.20, S = 0.140, W = 4.80, E = 2.90 k @ 4.0 ft Point Load : D = 3.10, L = 5.60, S = 0,630 k @ 15.50 ft Point Load: D =1.30, L = 2.70, S = 0.140, W = -4.80, E _ -0.290 k @ 23.0 ft Point Load: D = 3.350, L = 0.660, S = 3.40, W = 4.80, E = 2.90 k @ 25.50 ft DESIGN SUMMARY 244 at 2.0 in from Top, from 0.0 to 27.0 ft in this span Service loads entered. Load Factors will be applied for calculations. Maximum Bending Stress Ratio = 0.730: 1 Maximum Deflection Section used for this span Typical Section Max Downward L+Lr+S Deflection Mu: Applied 9.928 k-ft Max Upward L+Lr+S Deflection Mn ` Phi: Allowable 13.603 k-ft Max Downward Total Deflection Load Combination +1.20D+1.60L+0.50S+1.60H Max Upward Total Deflection Location of maximum on span 15.565 ft Span # where maximum occurs Span # 1 Maximum Soil Pressure = 1.831 ksf at 27.00 ft 0.000 in 0.000 in 0.051 in 0.000 in Design Overall Maximum Deflections - Unfactored Loads Load Combination Span Max. '2 Defl Location in Span Load Combination Max. "+" Defl Location in Span Span 1 1 0.0509 27.000 0.0000 0.000 Page 36 of 36 10 Rossproject: Engineering Design Inc DUECK ADDITION by: RR sheet #: location: 942 ALDER STREET, EDMONDS, WA 98020 date: 2/20/2018 client: THE LEREN COMPANY job #: 18016 Misc Calculations Wood Guardrail Posts (if applicable) M = 2001b x 42" = 8400 in -lb fb = 850 psi Cd = 1.6 Seq'd = M/fb/Cd = 6.1764706 in3 d = 3.50 in w = 3.50 in S = 7.1458333 in3 4x4 post OK with no notch Post Attachment M = 8400 in -lb s = anchor space = 5 in T req'd = M/s = 1680 lb DTT2Z = 1800 LB OK M = 2001b x 42" = 8400 in -lb fb = 850 psi Cd = 1.6 Seq'd = M/fb/Cd = 6.1764706 in3 d = 2.75 in w = 5.50 in S= 6.9322917 in3 6x6 post ok with 2.75" max notch GENERAL NOTES GENERAL REQUIREMENTS ALL WORK SHALL COMPLY WITH THE 2015 EDITION OF THE INTERNATIONAL BUILDING CODE (STRUCTURAL DESIGN), INTERNATIONAL RESIDENTIAL CODE (ORDINANCE), MOST RECENT EDITION OF THE UNIFORM PLUMBING CODE, INTERNATIONAL MECHANICAL CODE, NATIONAL ELECTRIC CODE, WASHINGTON STATE ENERGY CODE, ANY STATE AND LOCAL AMENDMENTS, AND ANY APPLICABLE LAND USE CODE. THE OWNEWBUILDER SHALL BE RESPONSIBLE FOR DEVELOPING CONSTRUCTION DETAILS NECESSARY TO CONSTRUCT WEATHER TIGHT, DURABLE BUILDING. ALL FLASHING, WEATHERPROOFING, ROOFING AND WATERPROOFING DETAILS AND CONSTRUCTION OF THESE DETAIL ASSEMBLIES ARE THE FULL AND COMPLETE RESPONSIBILITY OF THE OWNERIBUILDER AND THESE DETAILS SHALL BE CONSTRUCTED PER MANUFACTURER REQUIREMENTS, BUILDING CODE REQUIREMENTS AND ACCEPTED INDUSTRY STANDARDS FOR PERFORMANCE. THE DESIGNER HAS NOT BEEN CONTRACTED TO PERFORM CONSTRUCTION ADMINISTRATION SERVICES OR CONSTRUCTION OBSERVATION SERVICES FOR THIS PROJECT AND IS NOT LIABLE OR RESPONSIBLE FOR DETERMINING ADEQUACY OF CONSTRUCTION OF BUILDING ENVELOPE OR DETAILS. THE OWNER/BUILDER SHALL BE RESPONSIBLE FOR INSPECTING AND VERIFYING THAT ALL FLASHING, WEATHERPROOFING, ROOFING AND WATERPROOFING DETAILS ARE BUILT CORRECTLY AND MEET OWNERBUILDER'S APPROVAL BEFORE BEING COVERED BY SUBSEQUENT CONSTRUCTION WORK. USE OF THESE PLANS BY ANYONE OTHER THAN THE INTENDED OWNER/BUILDER IS NOT PERMITTED. ANY REDUNDANCY BETWEEN THESE NOTES AND S-SHEETS THE S-SHEETS SHALL SUPERSEDE SITE WORK 1. BACKFILL FOUNDATION DRAIN AT PERIMETER OF BUILDING WITH COURSE GRANULAR FILL. (11/2-3/8 CLEAN WASHED ROCK WITH MIN. 12" WIDE BLANKET EXTENDING TO FINISHED GRADE.) PROTECT DRAIN TILE AND WATERPROOFING. 2. ROUGH GRADING SHALL PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING. TRENCH TO ELEVATIONS BELOW FROST LINE FOR STORM DRAINS, WATER LINES, SEWERS, AND IRRIGATION SLEEVES. 3. PROVIDE PERFORATED PLASTIC PIPE FOUNDATION DRAINS WHERE SHOWN IN DRAWINGS. CONNECT TO ROOF AND STORM WATER SYSTEM. IN JURISDICTIONS REQUIRING SEPARATE ROOF DRAIN LINES, PROVIDE TIGHT LINE CONNECTED TO ROOF DRAINS IN ADDITION TO PERFORATED DRAIN LINES. 4. ROCKERIES AND RETAINING WALLS SHALL BE DESIGNED BY LICENSED ENGINEER AND INSTALLED PER APPLICABLE CODE. MECHANICAL 1. PLUMBING SYSTEMS SHALL BE DESIGNED AND INSTALLED BY COMPETENT, EXPERIENCED PLUMBER AND IN ACCORDANCE WITH THE UNIFORM PLUMBING CODE AND LOCAL CODES. 2. HVAC SYSTEMS SHALL BE DESIGNED AND INSTALLED BY COMPETENT AND EXPERIENCED MECHANICAL CONTRACTOR IN ACCORDANCE WITH THE INTERNATIONAL MECHANICAL CODE, 20151RC, AND LOCAL CODES. PROVIDE DOCUMENTATION OF FURNACE A.F.U.E. DUCTWORK INSULATION SHALL CONFORM TO THE WASHINGTON STATE ENERGY CODE. WHEN INSTALLED IN GARAGE, HEATING UNITS SHALL BE PLACED SUCH THAT ALL PILOT LIGHTS, BURNERS, HEATING ELEMENTS, OR SWITCHES ARE LOCATED A MIN. OF 18" ABOVE THE GARAGE FLOOR. THERMAL AND MOISTURE 1. INSULATION REQUIREMENTS SHALL MEET OR EXCEED THE LATEST EDITION OF THE WASHINGTON ENERGY CODE OR ENERGY CODE ADOPTED BY THE LOCAL JURISDICTION. INSULATION REQUIREMENTS SHALL BE SHOWN ON PLANS 2. APPLY 1 COAT (MIN) HEAVY BODIED ASPHALT BITUMINOUS DAMPPROFING TO EXTERIOR OF FOUNDATION WALLS, FROM FOOTING TO FINISHED GRADE AT FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE INTERIOR SPACES AND FLOORS BELOW GRADE- (R406.1) 3. APPLY APPROPRIATE WATER REPELLENTS TO ANY MASONRY, CEMENT, PLASTER, OR STUCCO PER - MANUFACTURER'S INSTRUCTIONS. 4. PROVIDE 6 MIL BLACK POLYETHYLENE VAPOR BARRIER IN ALL CRAWLSPACE AREAS, LAPPED AT ALL SPLICES AND OVER FOOTINGS. FINISHES GARAGE CEILINGS BENEATH HABITABLE SPACES SHALL BE COVERED WITH 5/8' TYPE'X' GYPSUM WALL BOARD. GARAGE CEILINGS BENEATH ATTIC OR NON UVING SPACE SHALL BE COVER WITH 5/8" GYPSUM WALL BOARD. WALLS AND STRUCTURE SEPARATING RESIDENTIAL AND GARAGE SPACES SHALL BE COVERED WITH 1/2" GYPSUM WALL BOARD. ALL GARAGE GYPSUM WALLBOARD SHALL HAVE JOINTS FIRETAPED WITH NAILS SET AND COMPOUNDED. ALL OTHER WALLS SHALL RECEIVE 10 GYPSUM WALLBOARD. CEILINGS WITH JOISTS/TRUSS SPACES GREATER THAN 16" SHALL RECEIVE 5/8" GYPSUM WALLBOARD OR ill" GYPSUM CEILING BOARD. WALLS SURROUNDING TUBS OR SHOWERS SHALL BE COVERED WITH WATER-RESISTANT GYPSUM WALLBOARD. WATER- PROOF SURFACE TO A HEIGHT OF 72" ABOVE ADJACENT FLOOR. ANY CEMENT PLASTER OR STUCCO SHALL BE INSTALLED IN ACCORDANCE WITH NORTHWEST WALL AND CEILING BUREAU RECOMMENDATIONS FOR MATERIALS, BACKING, LATH, APPLICATION TECHNIQUES, AND FINISHES. ELECTRICAL SYSTEMS SHALL BE DESIGNED AND INSTALLED BY COMPETENT AND EXPERIENCED ELECTRICAL CONTRACTOR IN ACCORDANCE WITH MOST CURENT STATE AND LOCAL ELECTRICAL CODE. ELECTRICAL SCHEMATICS PROVIDED IN THIS SET OF PLANS ARE FOR REFERENCE LAYOUT ONLY. FIRESTOPPING FIRESTOPPING SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND HORIZONTAL)AND TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY AND THE ROOF SPACE. FIRESTOPPING SHALL BE PROVIDED IN WOOD FRAME CONSTRUCTION IN THE FOLLOWING LOCATIONS: 1. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES NOT TO EXCEED 1B-0" HORIZONTALLY, AND AT THE CEILING AND FLOOR LEVEL. 2. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS, COVE CEILINGS, ETC. 3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN AND WALL CAVITIES IN LINE WITH STRINGERS. 4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS AND FIREPLACES AT CEILING AND FLOOR LEVEL, NTH NON-COMBUSTABLE MATERIALS. MISCELLANEOUS 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CONDITIONS, ETC. IN THE FIELD PRIOR TO PROCEEDING. 2. VERIFY SIZEAND LOCATION OF ALL OPENINGS IN THE FLOOR, ROOF, AND WALL WITH MECHANICAL AND ELECTRICAL WORK. 3. PROVIDE SMOKE DETECTORS IN ACCORDANCE WITH (R314) SMOKE DETECTORS TO BE HARD WIRED AND INTERCONNECTED. (R314.4, R314.5). A SMOKE DETECTOR SHALL BE INSTALLED IN EACH SLEEPING ROOM AND OUTSIDE EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS.(R314) CARBON MONOXIDE ALARMS SHALL BE INSTALLED OUTSIDE EACH SEPARATE SLEEPING AREA AND IN THE VICINITY OF THE BEDROOMS. (R315) 4. KITCHEN RANGE, DRYER, BATH AND LAUNDRY ROOM VENTILATION DUCTS SHALL TERMINATE OUTSIDE THE BUILDING AND BE EQUIPPED WITH BACK DRAFT DAMPERS. 5. EXTERIOR OPENINGS TO THE WEATHER SHALL BE FLASHED AND COUNTER -FLASHED IN SUCH A MANNER AS TO MAKE THEM WATERPROOF. ROOF FLASHING PER R903. 6. GUARDRAILS TO BE A MIN. OF 36"ABOVE FINISH FLOOR. (R312) (EXCEPTIONS TO COMMERCIAL PER I.B.C.) 7. OPEN GUARDRAILS TO HAVE INTERMEDIATE RAILS OR PICKETS PLACED SUCH THAT SPHERE 4" IN DIAMETER CANNOT PASS THROUGH. S. BEDROOM EMERGENCY EGRESS WINDOWS MUST HAVE A MIN. NET CLEAR OPENING OF 5.7 SQ. FT. MINIMUM NET CLEAR OPENABLE WIDTH OF 20"AND MIN. NET CLEAR OPENING HEIGHT OF 24". MAX. FINISHED HEIGHT OF 44" FROM FINISHED FLOOR TO BOTTOM OF CLEAR OPENING (R310.1). AREA CALCULATIONS HEATED AREAS SQUARE FOOTAGE EXISTING MAIN FLOOR 1275 EXISTING BASEMENT 1094 NEW ADDITION 864 TOTAL GROSS AREA 3233 NON -HEATED AREAS SQUARE FOOTAGE EXISTING GARAGE 558 NEW DECKS 154 BASEMENT A. D.U. TO MAIN RESIDENCE RATIO: MAIN RESIDENCE (WITH NEW ADDITION): 3233 A.D.U. IN BASEMENT: 1094 PERCENT ADU TO HOUSE: 33.8% Al A2 A3 A4 A5 A6 S1 S2 S3 S4 S5 S6 S7 DRAWING INDEX COVER SHEET, INDEX, GENERAL NOTES ENERGY CALCULATIONS ELEVATIONS BASEMENT ADU PLAN BASEMENT/GARAGE PLAN MAIN FLOOR PLAN STRUCTURAL NOTES/SCHEDULES STRUCTURAL DETAILS BUILDING CROSS SECTION, SHEARWALL & HOLDOWN LOCATIONS FOUNDATION PLAN MAIN FLOOR FRAMING ROOF PLAN MISC. DETAILS SYMBOL LEGEND OO CARBON MONOXIDE DETECTOR INTERCONNECTED 1IN w/ BATTERY BACKUP oo. CAN BE COMBINED W S.D. O SMOKE DETECTOR So. INTERCONNECTED 110v W BATTERY BACKUP GO EXHAUST FAN (VENT TO OUTSIDE) 0 KEYNOTE 101 DOOR SCHEDULE SYMBOL 71 WINDOW SCHEDULE SYMBOL Q REVISION -SEE DESCRIPTION IN TITLE BLOCK l SIM," DETAIL SYMBOL to SIMILAR DETAIL DETAIL NO. SHEET NO. l sIM 10 BUILDING CROSS SECTION DETAIL NO. SHEET NO. Room name— ROOMNAME 15- Know what below.STATE LAW REQUIRES THAT YOUOALL BEFORE YOU DIG TO Call before you dig. LOCATE ALL UNDERGROUND UTILITIES. ADDITION TO RESIDENCE � & BASEMENT CONVERSION TO AN ACCESSORY DWELLING UNIT 942 ALDER STREET, EDMONDS, WA 98020 Obtain Electrical Permit t'rom State Labor & Industries City of Edmonds Building Dcpn�_. ;. APPROVED PLC 0 t :.e s•. v lilt �s5g t " GIfppb� t b W U z W ce he U W 0 0 Q 0 z O ix LU z O t= 44 m W 0 a C14 O 00 CT Q Z O w H- W W H W W 01 J Q ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPR ED MIR • T CITY OF EDMONDS BUILDING DEPARTMENT WORK �W PROJECT NO. 171202 DESIGNED BY TL DRAWN BY TLBRM ADDRESS OWNER CHECKED BY TL ®APPROVED DATE:¢ BLDG.OFFICIAL: L SHEET NO. P[EtRBf1iRT NIU€'1f1BLER Al c 4a �-- MF1Y 3 21V19 RNTDATE 5B/201910:20:29AM R301 CLIMATE ZONE THIS PLAN IS DESIGNED FOR CLIMATE ZONE 5 AND MARINE 4 PER TABLE R301.1, 2015 WASHINGTON STATE ENGERY CODE. R402.2 FENESTRATION (PRESCRIPTIVE) R402.3 Fenestration (Prescriptive). In addition to the requirements of Section R402, fenestration shall comply with Sections R402.3.1 through R402.3.6. R402.3.1 U-factor. An area -weighted average of fenestration products shall be permitted to satisfy the U-factor requirements. R402.3.2 Glazed fenestration SHGC. An area -weighted average of fenestration products more than 50 percent glazed shall be permitted to satisfy the SHGC requirements. R402.3.3 Glazed fenestmliod exemption. Up to 15 square feet (1.4 m2) of glazed fenestration per dwelling unit shall be permitted to be exempt from U-factor and SHGC requirements in Section R402.1.1. This exemption shall not apply to the U- to. alternative approach in Section R402.1.3 and the total UA alternative in Section R402.1.4. R402.3.4 Opaque door exemption. One side -hinged opaque door assembly up to 24 square feet (2.22 m2) in area is exempted from the U-factor requirement in Section R402.1.1. This exemption shall not apply to the U-factor alternative approach in Section R402.1.3 and the total UA alternative in Section R402.1A R404.1 LIGHTING EFFICACY MIN. OF 75%OF LAMPS IN PERMANENTLY INSTALLED FIXTURES SHALL BE HIGH EFFICACY LAMPS. M 1507 MECHANICAL VENTILATION M1507.3.1 SYSTEM DESIGN. EACH DWELLING UNIT OR GUESTROOM SHALL BE EQUIPPED WITH A VENTILATION SYSTEM COMPLYING WITH SECTION M1507.3.4, Ml507.3.5. M1507.3.6 OR M1507.3.7. COMPLIANCE IS ALSO PERMITTED TO BE DEMONSTRATED THROUGH COMPLIANCE WITH THE INTERNATIONAL MECHANICAL CODE. M1507.3.2 CONTROL AND OPERATION. 1. LOCATION OF CONTROLS. CONTROLS FOR ALL VENTILATION SYSTEMS SHALL BE READILY ACCESSIBLE BY THE OCCUPANT. 2. INSTRUCTIONS. OPERATING INSTRUCTIONS FOR WHOLE -HOUSE VENTILATION SYSTEMS SHALL BE PROVIDED TO THE OCCUPANT BY THE INSTALLER OF THE SYSTEM. 3. LOCAL EXHAUST SYSTEMS. LOCAL EXHAUST SYSTEMS SHALL BE CONTROLLED BY MANUAL SWITCHES, DEHUMIDISTATS, TIMERS, OR OTHER APPROVED MEANS. 4. CONTINUOUS WHOLE -HOUSE VENTILATION SYSTEMS. CONTINUOUS WHOLE -HOUSE VENTILATION SYSTEMS SHALL OPERATE CONTINUOUSLY. EXHAUST FANS, FORCED -AIR SYSTEM FANS, OR SUPPLY FANS SHALL BE EQUIPPED WITH "FAN ON" AS OVERRIDE CONTROLS. CONTROLS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER ENERGY -CONSUMING APPLIANCES. A LABEL SHALL BE AFFIXED TO THE CONTROLS THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)." 5. INTERMITTENT WHOLE -HOUSE VENTILATION SYSTEMS. INTERMITTENT WHOLE -HOUSE VENTILATION SYSTEMS SHALL COMPLY WITH THE FOLLOWING: 5.1. THEY SHALL BE CAPABLE OF OPERATING INTERMITTENTLY AND CONTINUOUSLY. 52. THEY SHALL HAVE CONTROLS CAPABLE OF OPERATING THE EXHAUST FANS, FORCED -AIR SYSTEM FANS, OR SUPPLY FANS WITHOUT ENERGIZING OTHER ENERGY -CONSUMING APPLIANCES. 5.3. THE VENTILATION RATE SHALL BE ADJUSTED ACCORDING TO THE EXCEPTION IN SECTION 403.8.5.1. 5.4. THE SYSTEM SHALL BE DESIGNED SO THAT IT CAN OPERATE AUTOMATICALLY BASED ON THE TYPE OF CONTROL TIMER INSTALLED. 5.5. THE INTERMITTENT MECHANICAL VENTILATION SYSTEM SHALL OPERATE AT LEAST ONE HOUR OUT OF EVERY FOUR. 5.6. THE SYSTEM SHALL HAVE A MANUAL CONTROL AND AUTOMATIC CONTROL, SUCH AS A 24-HOUR CLOCK TIMER. 5.7. AT THE TIME OF FINAL INSPECTION, THE AUTOMATIC CONTROL SHALL BE SET TO OPERATE THE WHOLE -HOUSE FAN ACCORDING TO THE SCHEDULE USED TO CALCULATE THE WHOLE -HOUSE FAN SIZING. Ml507.3A WHOLE -HOUSE VENTILATION USING EXHAUST FANS. THIS SECTION ESTABLISHES MINIMUM PRESCRIPTIVE REQUIREMENTS FOR WHOLE -HOUSE VENTILATION SYSTEMS USING EXHAUST FANS. A SYSTEM WHICH MEETS ALL THE REQUIREMENTS OF THIS SECTION SHALL BE DEEMED TO SATISFY THE REQUIREMENTS FOR A WHOLE -HOUSE VENTILATION SYSTEM. M1507.3.4.1 WHOLE -HOUSE VENTILATION FANS. EXHAUST FANS PROVIDING WHOLE -HOUSE VENTILATION SHALL HAVE A FLOW RATING AT 0.25 INCHES WATER GAUGE AS SPECIFIED IN TABLE M 1 507.3.3(l). MANUFACTURERS' FAN FLOW RATINGS SHALL BE DETERMINED ACCORDING TO HVI 916 OR AMCA 210. M1507.3.4.2 FAN NOISE. WHOLE -HOUSE FANS LOCATED 4 FEET OR LESS FROM THE INTERIOR GRILLE SHALL HAVE A SOME RATING OF 1.0 OR LESS MEASURED AT 0.1 INCHES WATER GAUGE. MANUFACTURER'S NOISE RATINGS SHALL BE DETERMINED AS PER HVI 2 09). REMOTELY ISOLATED TELY MOUNTED FANS SHALL BE ACOUSTICALLY TED FROM THE STRUCTURAL ELEMENTS 915 (MARCH 0 OF THE BUILDING AND FROM ATTACHED DUCT WORK USING INSULATED FLEXIBLE DUCT OR OTHER APPROVED MATERIAL. M1507.3A.3 FAN CONTROLS. THE WHOLE -HOUSE VENTILATION FAN SHALL MEET THE REQUIREMENTS OF SECTION M1507.3.2AND M1507.3.2.1. M1507.3.4.4 OUTDOOR AIR INLETS. ' OUTDOOR AIR SHALL BE DISTRIBUTED TO EACH HABITABLE SPACE BY INDIVIDUAL OUTDOOR AIR INLETS. WHERE OUTDOOR AIR SUPPLIES ARE SEPARATED FROM EXHAUST POINTS BY DOORS, PROVISIONS SHALL BE MADE TO ENSURE AIR FLOW BY INSTALLATION OF DISTRIBUTION DUCTS, UNDERCUTTING DOORS, INSTALLATION OF GRILLES, TRANSOMS, OR SIMILAR MEANS. DOORS SHALL BE UNDERCUT TO A MINIMUM OF 1/2 INCH ABOVE THE SURFACE OF THE FINISH FLOOR COVERING. INDIVIDUAL ROOM OUTDOOR AIR INLETS SHALL: 1. HAVE CONTROLLABLE AND SECURE OPENINGS; 2. BE SLEEVED OR OTHERWISE DESIGNED SO AS NOT TO COMPROMISE THE THERMAL PROPERTIES OF THE WALL OR WINDOW IN WHICH THEY ARE PLACED; 3. PROVIDE NOT LESS THAN 4 SQUARE INCHES OF NET FREE AREA OF OPENING FOR EACH HABITABLE SPACE. ANY INLET OR COMBINATION OF INLETS WHICH PROVIDE 10 CFM AT 10 PASCALS ARE DEEMED EQUIVALENT TO 4 SQUARE INCHES NET FREE AREA, INLETS SHALL BE SCREENED OR OTHERWISE PROTECTED FROM ENTRY BY LEAVES OR OTHER MATERIAL. OUTDOOR AIR INLETS SHALL BE LOCATED SO AS NOT TO TAKE AIR FROM THE FOLLOWING AREAS: ` 1. CLOSER THAN 10 FEET FROM AN APPLIANCE VENT OUTLET, UNLESS SUCH VENT OUTLET IS 3 FEET ABOVE THE OUTDOOR AIR INLET. 2. WHERE IT WILL PICK UP OBJECTIONABLE ODORS, FUMES OR FLAMMABLE VAPORS. 3. A HAZARDOUS OR UNSANITARY LOCATION. 4. A ROOM OR SPACE HAVING ANY FUEL -BURNING APPLIANCES THEREIN. S. CLOSER THAN 10 FEET FROM A VENT OPENING OF A PLUMBING DRAINAGE SYSTEM UNLESS THE VENT OPENING IS AT LEAST 3 FEET ABOVE THE AIR INLET. 6. ATTIC, CRAWL SPACES, OR GARAGES. TABLE 1507.3.3 (1) CONTINUOUS WHOLE HOUSE MECHANICAL VENTILATION SYSTEM AIRFLOW FLOORAREA BEDROOMS' (SQ. FT.) 0-1 2-3 4-5 6.7 17 < 1500 30 45 W 75 90 (IN 1501-3000 45 60 75 90 105 3001-450D 60 75 90 105 120 4501-6000 75 90 105 120 135 6001-75DD 90 105 12D 135 150 >7500 105 120 135 150 165 TABLE 1507.3.3 (21 INTERMITTENT WHOLE HOUSE MECHANICAL VENTILATION RATE RUN-TIME PERCENTAGE IN EACH 4-HOUR SEGMENT 25% 33% 50% 66% 75% 100% - FACTOR 4 3 2 1.5 1.3 1.0 THIS PLAN USES AN INTERMITTENT WHOLE HOUSE VENTILATION SYSTEM WITH TOTAL HEATED FLOOR AREA=864 SO. FT. BEDROOMS =2 - WHOLE HOUSE VENTILATIONSIZE =45 CFM X4(25%PER 4-HOUR)= 180 TOTAL CFM FAN(s) SIZE. INTEGRATED FURNACE OUTSIDE AIR INTAKE WITH EXHAUST FANS AS NOTED IN PLAN. MULTIPLE WHOLE HOUSE VENTILATION FANS TO BE INTERCONNECTED TO OPERATE 2015 WASHINGTON STATE ENERGY CODE MISC. ENERGY CODE NOTES A permanent certificate shall be completed and posted on or within three feet of the electrical distribution panel by the builder or registered design professional. The certificate shall be completed by the builder or registered design professional and shall not cover or obstruct the visibility of the circuit directory label, service disconnect label or other required labels. The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundation (slab, below -grade wall, and/or floor) and ducts outside cone itioned spaces; U-factors for fenestration and the solar heal gain coefficient (SHGC) of fenestration, and the results from any required duct system and building envelope air leakage testing done on the building. Where there is more than one value for each component, the certificate shall list the value covering the largest area. The certificate shall list the types and efficiencies of heating, cooling and service water healing equipment. The building or dwelling unit shall be tested and vedfied as having an air leakage rate of not exceeding 5 air changes per hour. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals).W here required by the code official, testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Where the primary heating system is a forced -air furnace, at least one thermostat per dwelling unit shall be capable of controlling the heating and cooling system on a daily schedule to maintain different temperature set points at different times of the day. Specifics and Exceptions see SEC. ALL DUCTWORK SHALL BE SEALED AND TESTED PER R403.2.2. WINDOW AND DOOR HEADERS SHALL BE INSULATED WITH R-10 RIGID INSULATION EXCEPT IN SITUATIONS WHERE STRUCTURAL BEAM SIZE REQUIREMENTS OVERRIDE. ALL APPLIANCES SHALL BE U.L. LISTED. WHOLE HOUSE FANS Whole house ventilation fans shall be installed so as to run simultaniously. EXHAUSTFANS Exhaust fans to terminate at building exterior with clearances per SRC M1506.2 (min. 3 ft to openings) and for clothes dryer vent terminations to be per MI502.3 (3 it to bldg. openings). ALL FENESTRATION SHALL BE NFRC CERTIFIED. DBL. 2x6 TOP PLATES 1/2" G.W.B. -- 2" RIGID R-10 INSULATION INSTALLED IN CAVITY BETWEEN HEADER AND INTERIOR G.W.B. HEADER PER PLAN WINDOW, FINISH&TRIMS PER MISC. DETAILS NOTE: TYPICAL AT NEW CONSTRUCTION ONLY. STRUCTURAL BEAMS WIDTHS EXCEEDING 3.5" OVERIDE REQUIREMENT.. 1 HEADER INSULATION NOTE: SEE SHEETS S3 AND S7 FOR ADDITIONAL INSULATION LOCATIONS AND DETAILS. WINDOW SCHEDULE V I HEIGHT I AREA I WINDOW TYPE U VALUE COMMENTS ADDITION FLOOR 1 2'-6" 5-0' 113SF _ SINGLEHUNG 0.30 TEMP. GL. 2 2'-6" 5'-0" 13 SF SINGLE HUNG 0.30 TEMP. GL. 3 T-0" 4'-0" 28SF DOUBLE SLIDER 0.30 4 5'-(r 4'-0" 205F SLIDER 0.30 5 6'-0" T-0" 24 SF PICTURE (FIXED) 0.30 6 4'-0" 4'-0" 16SF PICTURE (FIXED) 0.30 7 6'-0" 4'-0" 24 SF PICTURE (FIXED) 0.30 8 4- 0" 3'-6" 14 SF SLIDER - 0.30 ADDITION PLATE 9 2'-0" 3'-0" 6SF SKYLIGHT 0.50 TEMP. GL. Grand total 157 SF GLAZING (ABOVE) 157 LESS EXEMPT GLAZING SF -00 SF PLUS GLAZED DOORS PLUS OTHER EXTERIOR 42 SF DOORS 215F TABLE R402.1.1 FOOTNOTES PRESCRIPTIVE ENERGY CODE COMPLIANCE HEATING SYSTEM SIZE 1 or SI:1 foot . 304.8 rum, ci .- continuous insulation, int.- intermediate framing Ft -values are minimums. U factors and SHGC are maximums. When insulation is installed in a cavity which is ass than the label or design thickness of the insulation, the compressed R-value of the insulation from ,ppendix Table A101.4shall not be less than the R-value specified in the table. The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration. "10/15/21.+TB" means R 10 continuous insulation on the exterior of the wall, or R 15 on the continuous Isulation on the interior of the wall,. or R 21 cavity insulation plus a thermal break between the slab and the asement wall at the interior of the basement wall. "10/15/21.+TB" shall be permitted to be met with R-13 evity insulation on the interior of the basement wall plus R 5 continuous Ill don on the interior or exteria ,f the wall. "30/13" means R-10 continuous insulation on the interior or exterior of the home or R-13 cavity lsulation at the tribal of the basement wait. "78" means thermal break between floor slab and basement R-10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1. There are no SHGC requirements in the Marine Zone. Reserved. Reserved. The second R-value applies when more than half the insulation is on the interior of the man wall. Reserved. For single rafter- or joist -vaulted ceilings, the insulation may be reduced to R-38. Reserved. ' Int. (intermed iate framing) denotes standard framing 16 inches on center with headers insulated with a ainimum of R 30 insulation. Nonfenestration U factors shall be obtained from measurement, calculation or an approved source or as 3ecified in Section ft402.1.3. Prescriptive Energy Code Compliance for All Climate Zones p 9Yin Washington Pm ecf In/ormari-n � c r rmrormahan DUECK ADDITIONERNIE DUECK 71 This Fmlect will .-he eAvoicanus ofine Prescriptive Path below and incorporate the the minimum values listed. In addition, based on the size of the structure, the appropriate number of additional credits are checked as ohosen by the permit applicant. Authorized Representative I51� .., .;All Climate Zones .;=-1 R Value- U Factor° Fenestration U-Factoe Va 0.30 Skylight U-Fecter n/a 0.50 Glazed Fenestration Etil a/a Na Ceiling° 49' 0.028 Wood Frame Well-'" 21 int 0.056 Mass Wall R-Value' 21/21" 0058 Floor so- Ott Below Grade wale''" ia15/21 int+TB O.lM2 Slab- R Value is Depth 10. 2 ft rm soh dwelling unit Ina residential buildino shall comply with sufficient options from Table R406.2 so as to achiave m following minimum number of credits: 1. Small 0wel mg Unit: 1.5 credits 'J Dwelling units less than 1500 square feet In conditioned floor area with less than 300 square feet of fenestration area Additions to existing building that are greater than 500 square feet of healed floor area but less Ihan 1500 square feet 12. Medium Dwelling Unit: 3.5 credits All dwelling units that are not included in 41 or 03. Exception: Dwelling units serving R-2 occupancies shall require 2.5 credits 7 3. Large Dwelling Unit: 4.5 credits Dwelling un is exceeding 5000 square feet of conditioned floor area. Table R406.2 Summary Total Credits "Please refer to Tabh,R406.2 forcompiete option descriptions 1.5 0.0 1.60 Sim le Heartina Samtent Size: Washin onState ThI learn, re I l k l based on rite Prescdot ve Reeulrerm t fth 2015W nl t St t E C tl'IWSECI' dAGFA M I J tl S 1ni 1 Wtor II calculate heating [,ad, i ACCA tl f II t h lab etl l tl t loads Please fill out all of the green drop -downs and becasthat are applicable to your project. As you make selectiens In the diopdowas for each aedbn, latedfor ff u do notaeethenlellon e values will be calve yo yo you need In the drop-dawnoptions, please call the WSU Energy Extension Program at l3fia)956-2042 for assistance. - - P,asid lnhrmafen Co nran lnrormanon '. DUEC1oK ADDITION-"181-� T1t „ Heatina Svstem Two: WTI cow syaem. Ciwtu,a,o ro aeeeemnea /oraeon aaanan, plena ywrcursoron fa. °era ^marrucnonr. Des^anT inarmandazure -"' - Des`gn�Tempaiawre Difference(AT) 46 Rk&g a7- rame,.ef o,mmovozba r..+m Area of Building Conditioned Floor Area _'.a.o Conditioned Floor Area (sq H) 'f8 Average Ceiling Height Conditioned Volume Innn.ons Average Ceiling Height(H) ;=:thR =:ti..._ 6,998 Chiral and Dears U-Factor X Area - UA � Nat naps -,1.2 88.00 W li vlahts k U-Factor % Area UA Inzuuc+lons 0.50 3.00 Insulation Allis UFacto, X Area UA L11O1S .."..._ w. h m 0.116 22.46 Singl R R J tV It tlCl q 'p DFeROr X ArmUA Ins ,ands ,a _ Above Brad, wall R h U-Faclor X Area UA Ins v o056 Yfc Z&3 "+f 42.73 Flo o U-Factor % Are UA _ 0.029 64fi9 25.06 But G d W ll p I UFactor X Area UA 1 `:..: 1.121 Slab B wGmdnr,re. I F-Facor X Len th UA Inst 0.303'it; Slab an Crude alv.� 1 .. F-Factor X Len th - .... ._..,....,„..,a UA. Ira . k Location of Ducts Du Leakage Coefficient 1.10 Sum of UA 159.25 Envelope Heat Load A Leakage Hers Lead 7,325 aw FHcuEARMI 3,4Tr Btul Hour Building 0eslga Healloatl 10,802 mu/Maur " Buildingand Duct Haag Load 11,882 BW/How Maximum .at Equipment Output 16,05 mul Hour 2 9 fi= cos; 3 ¢ 0 ®®®® I LL � Z U 0 0 Z 00 LU °� LU W > >Z > 0 0 ® U W C A LL1 W LU fn LpJ W 0 w F 0 ®y t�V Q ® IN Q 01 w o m a O a� 2 w Z M PROJECT NO. 1 171202 DESIGNED BY TL DRAWN BY TL & RM CHECKED SY Tl SHEET NO. A2P-EIMJJQ��) MAY 13 2019 r, @�s ryryortDP. PRINT DATE SM01910: D:45 AM 327 _93/8�ht — 4�— TOP OF RIDGE NEW ADDITION \ TOP OF NEW RIDGE327' - 2 3/8 wS D PICKE SPAC I � SUCH NEW GABLE OVERFRAME ADDITION PLATE I " I ,I, THAT A 4" SPHERE WITH TRIM AND .^ .... — CANNOT — — — — DECORATIVE_ — — - _ — A EXISTING HIP ROOF s '' 8 OVER NON -CONFORMING CORNER NEW 1 6— — — — — — —MAIN 315 8 l# a r1.._.. k r y ADDITION FLOOR _ ��,,__ � �-" '� � �" •- aF ' 313-05/8 - — — � GARAGE PLATE �_d L m rI , — .- - EXISTING HOUSE I -- .. I I 7-1 EXISTING GARAGE .. ..... . ... - l Average Grade.m. _ _ Max. Height TEMP. GL. — - 9 318 — — — — — TOP OF RIDGE A-,,32T, 32T - 2 3/8—" V ARCH. COMP. ROOFING TO MATCH EXISTING. CONTINUOUS ALUM. n SIDING AND TRIMS TO - MATCH n ADDITION PLATE— — _ _ _ __ — — — —— — — —_ 321' -1 31 5 Sim P 36' HIGH GUARDRAIL WI PICKETS SPACED SUCH THAT A 4" �. .,:c,' - - - - - SPHERE CANNOT PASS - -- -.... --- -- - MAIN FLOOR PLATE STAIRS AND HANDRAIL PER .. __ -_ -- --- --- ADDITION FLOOR _ 0 518" — — - " — — GARAG 3PLATE I1 Z-T � Y°'`" 1 4��� aE • L. I a�SSSsSa�is MAIN FLOOR — — — — — — — 7-10 _ BASMEN 3POLATOE c. �f-___. — -a Sao ;AGE F -1: In ELEVATION NOTES PROVIDE METAL FLASHING OVER TOPS OF WINDOWS AND TOPS OF TRIMS DIRECTLY EXPOSED TO WEATHER. ROOFING MATERIAL, SIDING AND FLASHING SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS, INDUSTRY STANDARDS AND PER I.R.C. PORCHES, BALCONIES, RAMPS OR RAISED SURFACES LOCATED MORE THAN 30" ABOVE THE FLOOR OR GRADE BELOW SHALL HAVE GUARDS NOT LESS THAN 36' IN HEIGHT. OPEN SIDE OF STAIRS WITH A TOTAL RISE OF MORE THAN 30" SHALL HAVE GUARDS NOT LESS THAN 34" IN HEIGHT MEASURED - VERTICALLY FROM THE NOSING OF THE TREADS. INTERMEDIATE RAILS OR ORNAMENTAL CLOSURES SHALL BE SPACED SUCH THAT A 4" SPHERE CANNOT PASS THROUGH. THE TRIANGLE OPENINGS FORMED BY THE RISER, TREAD, AND BOTTOM OF RAIL SHALL BE SUCH THAT A 6" SPHERE CANNOT PASS THROUGH. EXTERIOR STAIRS SHALL BE NOT LESS THAN 36" WIDE. HANDRAILS SHALL NOT PROJECT MORE THAN 4.5" ON EITHER SIDE OF THE STAIRWAY AND MIN. CLEAR WIDTH AT OR BELOW THE HANDRAIL SHALL NOT BE LESS THAN 31.5". MAX. RISER HEIGHT IS 7 3/4". MIN. TREAD DEPTH SHALL BE 10". A LANDING IS REQUIRED AT TOP AND BOTTOM OF EACH STAIRWAY. SITE ADDRESS SHALL BE VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. NUMBERS SHALL CONTRAST WITH BACKGROUND, BE ARABIC NUMBERS OR ALPHABETICAL LETTERS, BE A MIN. OF 4" IN HEIGHT WITH A MIN. STROKE WIDTH OF 10. (R319.1) =1 11=1 I I--- I I 1-1 11-1 ! 1-111-1 1 1=1 I I —I I "" EAST ELEVATION -- V MAIN FLOOR ----- — BASMENT PLATE 307' _ 0, ­­`:,_,_��;­_­­__ I I— NORTH ELEVATION 114" = 1'-0" _— RAIL CAP PER OWNER / METAL PIPE OR SQUARE VERTICAL POST AT 4" O.C. WITH INTERMEDIATE P,)CKETS SPACED SUCH THAT A 4" SPHERE - " CANNOT PASS THROUGH. PICKETS NOT REOIRED AT DECK LESS THAN m30" FROM GRADE, MIN. 200# IMPACT LOAD PER WHEELCHAIR FINISHED FLOOR WATER PROFFING MAX OPENING SUCH PER BUILDER THATA4"SPHERE CANNOT TRIM AND FASCIA _ PER BUILDER 3/8"x4" SS LAG SCREW (TYP. 4 PER BRACKET) DOUBLE 2x8 DECK FRAMING PER STRUCTURAL DECK RAIL 5 3/4" q t9 1naIga ci Lu Lu uJ DESIGNED BY TL DRAWN BY TL & RM CHECKED RY Tl SHEET NO. �® MAY-�,�.,k� G11Y Or Fj MOiVI. PRINT DATE 5/8/201910:21:06 AM NOTE! BASEMENT WALLS AND FINISHES ARE EXISTING. BASEMENT TO BE CONVERTED TO AN ACCESSORY DWELLING PER FILE NO.'PLN20180029. NOTE! EXISTING STAIRS TO MAIN FLOOR REQUIRED SMOKE AND CO2 DETECTORS AT A.D.U. TO BE INTERCONNECTED IN SUCH A WAY SO THAT IF ONE GOES BEDROOM OFF, ALL DETECTORS ON BOTH FLOORS, SHALL ACTIVATE. ai AS ALLOWED PER R302.3. —� - VERIFY AND/OR UPDATE EXISTING IXISTINGCONCRETE SMOKE DETECTORS WALKWAY ( (SEE NOTE') �1SD' 3 D.--- 8.0.l �y 8�g Pq @@°°aa gg �� PROPOSED A,&8,ffiP. UP EXISTINGI I I FURNACE — EXISTING CEILNG HT. r 1" —t. - --- - FIREPLACE EXISTING DOOR STORAGE UNDER = MECH. ROOM CLOSET. (VERIFY 112' --- EXISTING TEMP. MIN. G.W.B.) GL SIDELITES ELECT. WALL LEGEND . --- ----1 NEW WALLS EXISTING 8030 EGRESS WINDOWS �—� EXISTING WALLS TO REMAIN - @ 41" SILL HEIGHT. (TYP. @ 2 PLACES) i .------ WALLS AND STRUCTURES TO BE REMOVED �a ' . . -- a z — `. I — --- --- - :_ _ 1 � .� 2X FIRE EXISTING FLOOR i I BLOCKING JOISTS BEDROOM 0'-31/2' 1/2" GWB(EXISTING) ... ''•, I' -. - L.. - ... i .. 0'-2" DBL2X4 BLOCKING • r + sa LR•EU St1011 R _ S Na,I CC4 2X4 FURRING WALL 2X4 NON BRG INTERIOR WALL 0 p G't+ E�.SISTING 2 CAR STUDS SPACED 2X4 T16 O.C. UDS @SIDE. l-� - " 2"FROMCONCRETE WALL w51/2'GW8 TSUME EACH GARAGE = NINE" AT EXSTING INSULATION VALUES AND ffi" GWB AT INTERIOR FACE WITH IA PRIMERNAPOR BARRIER. Sim 4 4 EXISTING ) i FOUNDATION WALL CONTRACTOR TO VERIFY EXISTING P.T. 2X4 FLOOR I� OUTSIDE RETURN AIR TO FURNACE f� - PLATE wl 1/2" ANCHOR ROOMORI R - BOLTS CONCRINTO ETE @4IBTING O.C. P.T. 2x4 FLOOR M16022 REQL/N I ERIRCVIDE RETURN AIR PER IRC M1602.2. REQUIREMENTS. - - AND WITHIN I2"OF ENDS OR PLATE wl 11T ANCHOR AS CONSTRUCTED. BOLTS INTO EXISTING ' EXISTING CONCRETE CONCRETE @ 48" O.C. AND SLAB I. WITHIN 12" OF ENDS. A.D.U. ENTRY PANEL ISLAND WASH'R• ; CONTRACTOR TO VERIFY GWB BOTH /, .. ------- EXTERIOR STAIRS SIDES OFINTERIOR WALL AND/OR INSTALL GWB PER DETAIL 4/A4. —� TO MAIN FLOOR % j.S�ACE--.,',�\r ...-_._._... OR, ER A.D.U. CONVERSION AT -- — --- BASEMENT FLOOR -- _ -- .. ... ........ ___ _ _.___ .-- EXISTINGH.W.7. VERIFY 1/4"= I.-U° �12ANCHORAGE TO WALL PER I.R.C. 2 SOUTH ELEVATION DETAIL DEPICTS TYPICAL NEW WALL CONSTRUCTION AT BASEMENT AND ARE ASSUMED SIMILAR TO CUREENT CONSTRUCTION. INTERIOR WALL DETAIL �) 314" =1,_0„ Max. Height TOP OF RIDGE n — �HUI o � de skkgqa� O Lu O O C14 Z 00 ol Lu ILLS Lu 3 Z O 0 v ® Q >, W z O W C p H W F- W Lu Z LL® LLJ Q Q Q It 0, a 0 8 � � E c O. E z° PROJECT NO. 171202 DESIGNED BY TL DRAWN BY TL & RM CHECKED SY TL SHEET NO. 4L— n m MAY 13 ; 319 EPA Li PRINT DATE 5/8/201910:46:09 AM OralnEdge StriR Weathdoal tmwelapplied membrane hlpedandse9led Shines Wallshealhing 3 KICKOUT FLASHING DETAIL HANDRAIL, GUARD AND BALUSTERS TO CONFORM TO I.R.C. OPENINGS SPACED SUCH THAT A 4" SPHERE 10" RESIDENTIAL STAIRS'TO BE - 1 1/4" DIA. MIN; 7' DIA. MAX. HANDRAIL w/RETURNS TO WALL. DBL. JOIST (U.N.O. IN n S114PSON LUS210z JOIST TA10z EACH SIDE SIMPSON • OF TREADS TO OUTSIDE A35z STRINGERS EACH SIDE OF 012 P.T. STAIR TREADS OR EQUIV. PER OWNER 412 STRINGERS STAIR DETAIL - EXTERIOR 3/4" = 1'-0" GARAGE FLOOR IN Q O W z ® O V vi O AX ol B WL O ® u Z LuLu p �® 1= W Lu 06 u z Lu � o 0 ® Q ® N t Q 001 o � a 'm rc z 6 z N PROJECT NO. 171202 DESIGNED BY TL DRAWN BY TL&RM CHECKED BY TL SHEET NO. AS--c l ; MAY 13 219 PRINT DATE 5/8/201910:46:24 AM DOOR SCHEDULE SYM.NO. I W.DTH HEIGHT I DOOR TYPE COMMENTS ADDITION FLOOR D1 3'-0" . T-0" SINGLE ENTRY FIBERGLASS OR EQUIV. INSULATED ENTRY DOOR D2 6'-0" 6'-8" BI-PASS CLOSET DOOR D3 2-6" V-8' SINGLE PANEL - D4 6'-0" T-0" SLIDING GLASS PATIO (TEMP.) TEMP. GLASS(U=0.30) D5 r-6" V-8" SINGLE PANEL D6 5'-0" 6'-8' BI-FOLD 4 PANEL CLOSET DOOR D7 2'-6" 6'-8" SINGLE POCKET ' SINGLEPAIJEL -8' SINGLE PANEL D10 2'-0" 6-8' IsiNGLEPANEL D11 2'-6" 6'-8' ISINGLE PANEL WINDOW SCHEDULE SYM. NO. I WIDTH HEIGHT AREA I WINDOW TYPE U•VALUE COMMENTS ADDITION FLOOR 1 2'-6" 5'-0" 13 SF _ SINGLE HUNG 0.30 TEMP. GL 2 2'-6' S' 0" 13 SF SINGLE HUNG 0.30 TEMP. GL. 3 T-0 4'-0° 28 SF DOUBLE SLIDER 0.30 4 &-a" 4'-0" 20 SF SLIDER 0.30 5 6-0" 4'-0" 24 SF PICTURE (FIXED) 0.30 6 4'-0" 4' 0" 16 SF PICTURE (FIXED) 0.30 7 V-0" 4'-0" 24 SF PICTURE (FIXED) 0.30 8 4'-0" T-6" 14 SF SLIDER 0.30 ADDITION PLATE - 9 2'-0° 3'-0" 16SF ISKYLIGHT 0.50 ITEMP.GL Grand total . 157 SF KEYNOTE SCHELDULE IKEY VALUE TEXT 02 LANDINGS: THERE SHALL BE A FLOOR OR LANDING AT EACH SIDE OF EACH EXTERIOR DOOR. LANDING OR FLOOR SHALL BE A MAX. 1.5' LOWER THAN THE TOP OF THE THRESHOLD; 7 314" IS PERMITTED AT EXTERIOR DOORS THAT DO NOT SWING OVER THE LANDING, MAX. LANDING SLOPE IS 1/4:12. (R311.3.1 & 311.3.2) 04 COOKING APPLIANCES: HOUSHOLD COOKING APPLIANCES SHALL BE LISTED AND LABELED AND INSTALLED IN ACCORDANCE WITH MANUR SPECS. RANGE HOOD SHALL HAVE LIGHT & 100 CFM MIN. EXHAUST FAN AND BE VENTED TO OUTSIDE WALL. EXAHUST HOOD SYSTEMS IN EXCESS OF 40D CFM SHALL BE PROVIDED WITH MAKE UP AIR IN THE AMOUNT EQUIV. TO THE EXHAUST RATE. (M1503) 06 GUARDS SHALL BE REQUIRED AT OPEN SIDED WALKING SURFACES, PORCHES, STAIRS, RAMPS, BALCONIES AND LANDINGS LOCATED MORE THAN 30" ABOVE THE FLOOR OR GRADE BELOW. GUARD SHALL NOT BE LESS THAN 36' IN HEIGHT. OPEN RAILS SHALL HAVE INTERMEDIATE RAILS SPACED SO THATA 4" SPHERE CANNOT PASS "THROUGH. (R312) 08 EGRESSWINDOWS: OPENINGS ARE REQUIRED FOR ALL SLEEPING ROOMS AND BASEMENTS. BOTTOM OF CLEAR OPENING OTT 44" FLO R. ENAB IS .N MI PT S. .ISA FO AN NG WI 4°OFF S DGR 310.1) 09 DIRECT VENT GAS FIREPLACE SHALL BE INSTALLED PER MANUFACTURER SPECS. AND IN STRICTACCORDANCE W/ LOCAL BUILDINGCODES. MUST BE U.L. LISTED. (M73D3/G2427.2.1) 1 DRY :VENT TO UTSIDE PER MAN ACTURER ECICATIO . DUCTS S LL HAVE A MOOTH I RIOR FlNIS AND UC ET DU H P M ... OR 2. 4.2. 11 TYPICAL EXTERIOR WALL: SIDING o/ INFILTRATION BARRIER of EXTERIOR SHEATHING PER STRUCTURAL PLANS d 2X6 STUDS @ 16" O.C. w/ R-21 BATT INSULATION AND 11T MIN. GWB AT INSIDE FACE w/ P.V.A. PRIMER 12 PILOTS, BURNERS, & SWITCHES TO BE I8"MIN. ABOVE FLOOR. ALL APPLIANCES TO BE U.L. RATED. DUCTS IN GARAGE AND THOSE PENETRATING THE WALLS OR CEILINGS SEPARATING THE GARAGE FROM THE DWELLING SHALL BE 26 GA. SHEET STEEL AND SHALL HAVE NO OPENINGS IN THE GARAGE. WATER HEATERS SHALL BE ANCHORED AGAINST MOVEMENT AND OVERTURNING IN ACCORDANCE WITH M1307.2. PROVIDEPRESSURE RELIEF LINE PLUMBED TO OUTSIDE. - 17 CLOSET ROD w/ VINYL COATED WIRE SHELF 19 TEMP. GLASS DOOR 20 TEMP. GLASS WINDOW 22 ONE PIECE SHOWER WITH TEMP. GLASS SHOWER DOOR. 25 PANTRY SHELVING: PROVIDE (5) MELAMINE OR EQUIV. 16" DEEP SHELVES PER BUILDER SPECIFICATIONS. WALL LEGEND NEW WALLS }.# EXISTING WALLS TO REMAIN ------ WALLS AND STRUCTURES TO BE REMOVED A B QC D E F 2T-3" 1'-51n". 13'-61n' 12'-3" I 36' HIGH GUARDRAIL I / PICKETS SPACED STING j-- •-'- '== - -^--T _ :--.9--- - ---- CANNOT PASS THROUGH. - COIRNEROP �HE NONICONRMING I., I GARAGE. -- l.' j 8-- 06 �— BEDROOM ! BEDROOM \ DES i6 .'y 4•-710 4'-71n" ---2 MASTER 1 —I _ f ,� D4 I INTERIOR 1 20 VAULT — -._........J't.� __,,,,,"_„•"R_„ ._..._. _ ......_ i�..__ _._.._. - .20 19 -�— INT5' ERIOR VAULT -61n' S-91n'I- 7 I. BOOKCASE EXISTING MAIN FLOOR 51n„ F4 D7 I� •' I�'� I� I � I .. j .. IIj O9 I LIVING RAM__ -, GAS FIREPLACE I j I, EMP. GL.I WI,C,I 17 0 0 6 FAMILY RM ';LIVING ---- j GL '"+ I L._.. �- .� � SKYLIGHT iSOCFM HOLE HOUSE F N w/ ilk 5 3'-7­ TIMER(V it jl EDGE OF GAR EBELOW I BATH s 22 - -I - �, ET 4'x3'SHOWER� ..._I 0 �� w - I D10 WASH'R 10 KITCHEN Ds l I 25 3J_ ..s.o. D5 DRYR , I ............._-._ I , I bI � w------- NIN�� 3'-210 3'_9" T-1112 --- r...-. ---77.i'-- II KITCHEw D2 GUEST RM � - --- --- I 17 i --- ,'Sim .o& 3 --- (TYP.) Tt EXTERIOR ,o ENTRANCE 02 38" HIGH GUARDRA\ DOOR �`. O6 \ w/ PICKETS SPACED, SUCH THAT 4"SPHERE \\ / CANNOT PASS THROUGH. CLIPPED BACK OF DECK V I A TO MAINTAIN A 5 FOOT TuAcK FROM I I PRO PERTYDNERAST- i 0 z-41n" 5' -6" -Liz, '-2 14'-3' 11'•0" 4'-0" li ADDITION FLOOR 1/4" =1'-0" 6 z z E 9L 6 O U�� z� 09 v W m J 0 W u F 3 wzj nu ass o t §gtia§ � ,oa19 � UP ��1 ci 4 O W z V N 0 O ol O>>l Lu Z ® I , Z Lu LLl W f- LL1 oji � Vz O ® Q 0 Cl CV d Ornm�, v a a co ro rc E m ^'cam W Y 0 d z m m n PROJECT NO. 171202 - DESIGNED BY TL DRAWN BY TL & RM_ CHECKED BY TL 19 SHEET 110. MAY 13 W PRINT DATE 5/8/201910:47:14 AM �.. GENERAL NOTES All design and construction shall conform to the requirements of the International Building Code 2015 Edition. ENGINEERED COMPOSITE LUMBER: Engineered Composite Lumber shall be manufactured by Trus-Joist, Boise Cascade or approved equal and shall have the following minimum strength (based on 12"member depth): Contractor shall verify all levels, dimensions and existing Architect to field before proceeding with Symbol Fb E any construction or demolition. Contractor shall notify the Architect of any discrepancies Or field changes PSL 2600 psi 2,000,000 psi LVL 2600 psi 2,000,000 psi LSL 1700 I 1,300,000 I psi psi Contractor shall be responsible for all safety precautions and the methods, techniques, sequences or procedures required to perform the work. Contractor shall provide adequate shoring and bracing of Versa -Lam (i -2 8") 2800 psi 2,000,000 psi all structural members, existing construction and soil excavations as required, in a manner suitable - Versallam (3yz" &wider) 3100 psi 2,000,000 psi to the work sequence. Temporary shoring and bracing shall not be removed until all final PREMANUFACTURED OPEN WEB WOOD TRUSSES: Trusses shall be design by a Structural Engineer connections have been completed in accordance with the drawings and materials have achieved I;ro_ ;",Ae c,,,e of We°h;,,,,b, ,,,,,_,,, ro,,;,,,,, ,,,,,,,,,,,,, ;_ °L.-._",__ _� -.-- �r� P WOOD FRAMING PER PLAN PT SILL PLATE w/ANCHOR BOLTS I I VARIES I I PER SHEAR WALL SCHEDULE I BOLTAT48' o c�WHE E;SHEAR 1 I I 1 WALL IS NOT INDICATED). I I 7" MIN. EMBEDMENT. I I I 2q" 24' -- HOLD-DOWN ANCHOR SCHEDULE HOLD-DOWN ANCHORINCONC. STEM WALL ANCHORIN THICKENED SLAB EPDXY ANCHOR IN EXISTING FOUNDATION *FLOOR TO FLOOR ANCHOR HDU4 583` x 24 PABS x 6" EMBED -TABS 59 DIA. x8" EMBED �" DIA. HDUS SB x 24 s/e" x 6" EMBED DIA. x8" EMBED %" DIA. HDUB 56 T/B x 24 PA87 x 8�J" EMBED %" DIA. %12" EMBED HDUll SB 1 x 30 PABS x 10' EMBED I" DIA. x14" EMBED I" DIA. HDU14 SB 1 x 30 PA B8 z 10 EEMBED 1" DIA. xlb" EMBED 1" DIA. design strength. Foundations walls rester than 4 feet shall not be backfilled until the Boor framing ' """"`"" "" `"'-` "' ""'"""'""' """'" "'""" •r "'y">"" ••• " " 11. -' 1— `�""""" - - I-aasa GRI16E Ib g g g wood trusses. Truss desi n shall be accordance with IBC Section 2303.4. Trusses shall be designed #4 HORIZ. AT 12" o.c. AND (2) AT and all Connections to the floor framing per these details are complete. g g TOP OF WALL TYP. WALL THREAD ROD for 10 psf top Chord dead load plus 5 psf bottom chub dead load (15 psf total). In addition to dead WALL - � 24„ REINF. ANCHOR TYPE CHANGES: No changes to these structural drawings are ermined without wd[ter. consent of the loads, the design shall include the live, wind, snow and snow drift loads as Identified In the "Design THICKNESS HOLD-DOWN PER PLAN g g P Loads" section of these drawings. In addition, the truss design shall Include Concentrated and axial _PER PLAN #4 VERT. DOWELS AT 18" o.c. Engineer. Changes will be billed to the client, owner or contractor at the Engineer's howdy rate. loads shown on framing plans and hanger schedules in these drawings. Trusses shall be designed ALTERNATE HOOK AT BOTTOM 24" SUBMITTALS: Shop drawings shall be submitted to the Architect prior to any fabrication or for wind net uplift of 30 psf unless otherwise noted on the drawings. construction for all the following: Trusses shall be fabricated by a manufacturer who is a member of the Truss Plate Institute. Trusses M PERFORATED pOTING PER PLAN Concrete reinforcement, embedded steel items, structural steel, steel canopies, shall be supplied with the proper hangers, end connections, bridging, bracing to provide lateral FIG. DRAIN glued -laminated in and pre -manufactured wood members. stability of all truss members, and tie -down connections to beams and tops of walls. Trusses shall CON T. W he supplied with tapered hardwood shimming so that every chord hears on the full width of every W ANCHOR PER Design drawings and calculations, for pre -manufactured Prole woad trusses and joists shall bear the seal -- - SCHEDULE and signature of the Washington State Registered Professional Engineer who is responsible for the support, without notching the truss members. The truss manufacturer is responsible for ensuring design, and shall be submitted to the Architect and Building official for review prior to fabrication. the bearing seat does not exceed the sill plate capacity of the supporting element. ADD #4 z48" FOUNDATIONS PREMANUFACRJRED WOOD I -JOIST: Shall he fabricated by Truss -Joist or Boise Cascade. _ ., AT EACH ANCHOR Alternative manufactures must be approved by the Architect or Engineer. Joists shall be Installed dl ALT. HOOK • according to the manufactures instructions including blocking, web stiffeners, bridging, etc. Fasten BEAM PER PLAN Concrete foundations shall bear on stiff, competent, undisturbed native soil. Prior to construction, the contractor shall obtain confirmation from the Building Official that the native Boll at this project joists to supports as recommended by the joist and hanger manufacturer. Provide temporary I` - isadequatetoebeari gpresSumthe uedforsng pressure: openigasrecommended bsonly the owedbythmanufacturer manufa tuner.inplaceuntilpermanentiysecured,Cut TYPICAL CONCRETE FOUNDATION WALL 1 TYPICAL CONC. WALL CORNER REINFORCING 2 TYPICAL HDU HOLD-DOWN ANCHORS $ Allowable bearing pressure used for structural design = 2000 W. (assumed) openings in fist webs only as allowed by the manufacturer. Where footings must bear on structural fill due to inadequate soil Conditions, the fill shall be mixed MINIMUM WOOD NAILING REQUIREMENTS: Unless otherwise noted on the drawings, typical wood and compacted in accordance with specifications provided by a Gcotechniwl Engineer licensed in - framing shall be fastened in conformance with th e n Ong State of W h' to n. IBCTable23Rafter DIAPHRAGM NAILING SCHEDULE Joists/Rafters Bottom of footing elevation shall be located at minimum frost depth 18" below top of finished grade Jotst/Rafter to plate, sill or girder (3) 8d common toe nail NAIL SPACING NAIL SPACING AT unless required otherwise by the Building Official. The contractor shall confirm the minimum frost Blocking/Bridging (8)16d EACH SIDE (8) 16d EACH SIDE depth with the Building Official prior to excavation. - FLOOR BOUNDARY AT BOUNDARIES INTERMEDIATE NAIL SPACING OF SPLICE P P Bridging to joist (2) Bd common toe nail NAILING PER BLKG SIZE OF AND "OTHER" FRAMING AT BLOCKED (16 TOTAL) OF SPLICE (16 TOTAL) Blocking between joist to top plate (3) 8d common We nail FLOOR BOUNDARY DIAPHRAGM SCHED LOCATION SHEATHING REQD NAIL PANEL EDGES MEMBERS PANEL JOINTS CONCRETE Double top plates TOP PLATES Top plate to studs (2) 16d common end nail SOLE PLATE CONNECTION NAILING PER ROOF SEE STRUCT NO 10d 6" OC 12" OC 6" OC Concrete work shall Comply, In general, with AC[ 301 (latest edition) "Specifications for Structural PER SHEAR WALL SCHED DIAPHRAGM SCHED Concrete for Buildings." - Nall together I6d common 16" o.c. face nail SUB-FLR NOTES NO lOd &GLUE 6" OC 12" OC 6" OC 4'-0" MIN4,1 ,_, _""......"...",... ,.".. CONCRETE MIXES: Concrete mixes shall conform ACE 318 Ch. 5. Minimum concrete strength fc at - Lap splices (8) 16d wmmon face nail e n Ong State of W h' to n. IBCTable23Rafter DIAPHRAGM NAILING SCHEDULE Joists/Rafters Bottom of footing elevation shall be located at minimum frost depth 18" below top of finished grade Jotst/Rafter to plate, sill or girder (3) 8d common toe nail NAIL SPACING NAIL SPACING AT unless required otherwise by the Building Official. The contractor shall confirm the minimum frost Blocking/Bridging (8)16d EACH SIDE (8) 16d EACH SIDE depth with the Building Official prior to excavation. - FLOOR BOUNDARY AT BOUNDARIES INTERMEDIATE NAIL SPACING OF SPLICE P P Bridging to joist (2) Bd common toe nail NAILING PER BLKG SIZE OF AND "OTHER" FRAMING AT BLOCKED (16 TOTAL) OF SPLICE (16 TOTAL) Blocking between joist to top plate (3) 8d common We nail FLOOR BOUNDARY DIAPHRAGM SCHED LOCATION SHEATHING REQD NAIL PANEL EDGES MEMBERS PANEL JOINTS CONCRETE Double top plates TOP PLATES Top plate to studs (2) 16d common end nail SOLE PLATE CONNECTION NAILING PER ROOF SEE STRUCT NO 10d 6" OC 12" OC 6" OC Concrete work shall Comply, In general, with AC[ 301 (latest edition) "Specifications for Structural PER SHEAR WALL SCHED DIAPHRAGM SCHED Concrete for Buildings." - Nall together I6d common 16" o.c. face nail SUB-FLR NOTES NO lOd &GLUE 6" OC 12" OC 6" OC 4'-0" MIN4,1 ,_, _""......"...",... ,.".. CONCRETE MIXES: Concrete mixes shall conform ACE 318 Ch. 5. Minimum concrete strength fc at - Lap splices (8) 16d wmmon face nail ,_, _""......"...",... ,.".. CONCRETE MIXES: Concrete mixes shall conform ACE 318 Ch. 5. Minimum concrete strength fc at - Lap splices (8) 16d wmmon face nail I ,..°�� BLKG DIAPHRAGM NOTES 1. ALL DIAPHRAGM SHEATHING IS TO BE STAGGERED IN THE DIRECTION OF THE PLYWOOD SPAN PER 28 days shall be as follows: Sole plate DIAPHRAGM DETAIL Slab -on -grade, Curbs and Pads - 2000 psi Sole plate to studs (2) 16d common end nail or ( 2. PROVIDE BOUNDARY NAILING CONTINUOUS AROUND THE ENTIRE PERIMETER OF THE DIAPHRAGM - Footings - 2500 psi (4) 8d common toe nail --------,--------_-.........__-�_ 3. NAILS SHALL BE COMMON OR GALVANIZED BOX Sole plate to rim joist/blocking l6d common 6" Walls, Stems - 0 psi (2500 psi used for structural design) o.c. face nail 3D0 (ADD BLOCKAT DECK 4. ALL FRAMING MEMBERS SHALL BE 2z MINIMUM NOMINAL WIDTH Studs TIES I BLOCKED DIAPHRAGM TYPICAL CONTINUOUS Water/cement ratio shall be measured by weight and shall be based on the total cementitious Built up stud posts & corners 10d Common 8" D.E. face nail ' ' ' CONT RIM JOIST WHERE INDICATED PANELJOINT - material. Water/cement ratio shall be determined by the supplier based on strength requirements ' Studs to header (4) 8d common toenail and shall not exceed 0.11. Water -reducing admixtures may be Incorporated in concrete mix designs N- " F A �:'=. STUDS but shall conform to ASTM C 464, and be used in accordance with the manufacturer's BUILDING OFFICIAL INSPECTIONS recommendations. CaCI and other water-soluable chloride admixtures shall not be used. . The following recommended minimum items shall be inspected by a qualified individual provided BOUNDARY H y n n - B' by the Building Official' REINFORCING STEEL: "Foundations" DECKJOISTS PER PLAN NAILING n n 't n - p TOP PLATE U '� U 0 U -Footings bear on competent native soil per the section above • Deformed Bars - - ASTM A 615, Grade 60 -Footing reinforcement SHEARCLIPS PER BLOCKED CONTINUOUS R R .. U Il. U - "OTHER" PANEL Galvanized Welded Wire Fabric - ASTM A 165 -Sheaf wall sill plate anchors and Washers per schedule DECK TIE PER PLAN SHEARWALL SCHED (BLKG TO TOP PLATE) PANEL JOINT 'rY.f3 U R EDGE NAILING N y = H '.,j NOTES: - SEE STRUCTURAL NOTES FOR TYPICAL TOP . -Shear wall nailing and Sheaf clips per schedule Reinforcing steel be detailed accordance with ACT 315 °Manual of Standard Practice for l -Shear Wdll hold-downs t U U 1 i '- INTERMEDIATE lOI5T/TRUSS PLATE NAILING NOT SHOW N Detailing Reinforcedd Concrete Structures." -Verify type, size and grade of structural steel members and bolts EDGE NAILING NAILING Reinforcing steel shall be lapped as noted on the drawings. Where lap length is not shown, - - DESIGN LOADS DIAPHRAGM DETAIL reinforcing bars shall be lapped as follows: SECTION 4 TYPICAL DIAPHRAGM NAILING 5 TYPICAL TOP PLATE SPLICE 6 #5 and smaller -48 bar diameters LIVE LOADS: Live loads are determined in accordance with ASCE Ch.7 #6 and larger -60 bar diameters - L = 40 PSF(Residential) _ Minimum concrete cover over reinforcing shall be n follows: SNOW LOADS: Snow loads are determined in accordance with ASCE Ch. 7 with the following ... Nonstructural Slab -on -grade - Mid -Depth Factors: Wall Bars: interior face - 3/4" Ground Snow Load Pg = 20 psf Ct = 1.0 Ce = 1.0 exposed to earth/weather - 1-1/2" (#5 and smaller) Roof Snow Load Ps = 25 psf Is = 1.0 2" (#6 and target) Footings: Bottom Bars - 3" Cast against earth WIND LOADS: Wind loads are based On ASCE 7-10 d1. 28 EnvelO a Procedure With the tolbWin 9 ( 9 ) ( P ) 9—POST SIMPSON CS16 SUB FLOOR WITH (20)16d PER PLAN TO RIM JOIS� BEAM PER PLAN NOTES: I� ^HI^ DETAIL APPLIES^AT ALL POST TII ttl'—I'm'_ PER PLAN -SOLID BLKG MATCH WHEREGIRDER WIDTH OF BEAM/GIRDER APPLICABLE -Top Bars - 1-1/2" factors: Side Bars - 2" Exposure Category = B Iv✓ = 1.0 ' -- Velocity (3 sec) =110 mph (ult) Kzt = 1.0 — --- --- LEVELS NOLD-DOWN PER PLAN WHERE CRIPPLESTUDSAT ".' O.C. WHEREAPPLICABLE Provide supports as required. for proper alignment and concrete cover around the reinforcement. Design wind pressured for determining forces on components and cladding are determined in Consult the CRSI Manual of Standard Practice MSP-1 for specific information. accordance with ASCE 7-10 Chapter 30. - -- ADD SOLID BLKG. MATCHING WIDTH AND APPLICABLE TOP PLATES "— DEPTH OF POST ABOVE. ANCHORS SEISMIC LOADS: Seismic loads are based on the Equivalent Lateral Force Procedure in ASCE 7-10 Use of drilled concrete anchors, including expansion bolts and adhesive anchors, where not Section 12.8 with the following factors: - Risk Category = Ss = 112 I 1 I I----J specified in these documents shall be subjeC to approval by the Architect. D =D SI =0.497 0*497 _.. SIMPSON CSl6 WITH 20 ( ) .._,.........._......... _............... -SItoC1a55 EXPANSION BOLTS: Expansion bolts in solid concrete shall be wed e- p g type anchors made of carbon Design Category = D SOS = D.847 16d TO DEL. TOPPLATE NAIL STUD TO HEADER W/ (8)16d steel. Bolt sae, spacing and embedment length shall be as designated in these drawings. Bolts shall R = 6.5 (wood shear wall) SDI = 0.498 - be Installed per the manufacturer's Instructions rs with inspection per schedule. Expansion boils shall Ie = 1.0 Cs = 0130 (ult.) .. STUD AT EACH SIDE. be Simpson Strong Bolt 2 Or approved equal. A current ICBO or ICC Report shall be submitted for SHIM AS NEEDED. RIM JOIST PER PLAN alternates. ' I- `� STUD(S) PER PLAN FULL HEIGHT ADHESIVE ANCHORS: Adhesive ore z epoxy type anchors in Solid Concrete shrill be Installed per the - POST PER PLAN FLOOR FRAMING TO TOP PLATES - manufacturer's instructions. Anchor size, spacing and embedment length shall be as designated in NOTES: FLOOR FRAMING BOTH SIDES WHERE these drawings. Adhesive shall be Simpson AT-XP. A current ICBO or ICC Report shall be submitted for alternates. TYPICAL DETAILS In addition the details and schedules on the framing plans, those noted as 'Typical" l" shall be I used throughout thh 1. USE THIS DETAILAT ALL LOCATIONS WHERE BEAM WIDTH EXCEEDS 3)4"AND/OR BEAM BOTTOM BEARING IS BELOW DOUBLE TOP PER PLAN ' APPLICABLE HEADER PER PLAN WOOD s e Structure a5 applicable. PLATES. TRIM STUDS (TRIMMERS) SAWN LUMBER: Structural sawn lumber shall be kiln dried and be of the species and grade noted 2. EXTEND BEAMS FOR 5-1/2" BEARING ON 2x6 WALLS, 3-1/2" BEARING ON 20 WALLS. CONCRETE WALL BELOW WHERE ' POST PER PLAN PER POST PLAN below or better: '- APPLICABLE _ Use , Grade Fb i Wall Studs -Stud 675 TYPICAL PLATE STRAP AT BEAMS 7 TYPICAL POST BLOCKING $ TYPICAL HEADER DETAIL 9 Plates & Planks Hem Fir #2 850 . Joists & Rafters Hem Fir#2 850 4x Beams. Douglas Fir -Larch #2 900 - 6x Beams 'Douglas Fir -Larch #2 875 Posts Douglas Fir -Larch #2 750 2x4 T&G Decking Douglas Fir -Larch Select 1750 NOTE: SOd @ 3" o.c. ROSS ENGINEERING HAS PROVIDED All lumber and plywood in contact with concrete, stuaro, masonry or other cementitious materials 2x BLKG CALCULATIONS FOR THE EDGE shall be treated with an E.P.A. acceptable wood preservative, such as Alkaitne-Capper-Quaternary MEMBER TO SUPPORT GUARDRAIL "ACQ" or Copper Azole "CBA" type A and B. 2x BLKG W/ LOADS.THE GUARDRAIL 616 OR AxA GUARDRAIL POST All wood connectors shall be manufactured by Simpson Strong Tie Company (or approved equal), (3) SDS25312 EA. BLOCK MANUFACTURER SHALL SUBMIT CALCULATIONS FOR THE POST PER PLAN and of the size and type shown on the drawings. All wood wnnecbcm in contact with ATTACHMENT INTO THE EDGE preservative -treated wood shall be Triple Zinc G-185 galvanized (1.85 ce/sq it coating). ' 10d @ 3" O.C. GVARORAIL BY OTHERS MEMBER INCLUDING THE FASTENERS. " RATED SHEATHING: Wood Structural panels Shall bear the APA trademark of the American Plywood I>a Y CONT 2x SHAPED BLKG POST BASE PER Association. Sheathing shall be as ficil B: - _ %-"'C GUARDRAILATTACHMEm DESIGNED BY MANUFACTURER _`` _ 2 3/4" MAX NOTCH AT 6x6 SCHEDULE Shear Wall Shtg 7/16" 32/16 C-D INT APA with Exterior Glue (CDX) - .Roofshtg 15132" 32/16 C-D INTAPA with Exterior Glue (CDX) SHEAR CLIPS PER EDGE DTr2ZrvlTH iS•' DIA. eoD DTIR WNH 3G"DIA. BOLT 12" SONO Sub Floor Shtg 3/4" 48/24 T&G C-D ANT APA with Exterior Glue SHEAR WALL SCHED. .TOJOIST/BLRG. TO GRAD shall be Orientated over the supports as shown the drawings. Shear wall sheathingshall (3) #4 VERNAILINGSheathing be blacked at all panel edges as shown in the shear wall schedule. a DOWELS GLUED LAMINATED MEMBERS: Glued Laminated members shall each bear an AITC identificationFOOTING mark and be accompanied by an ALTC certificate of conformance. One coat of end sealer shall be Hi CLIP EACH TRUSSappliedirtlmediateyafter PER AAI trimming either shop or field. Members shall be Visual Graded Western 0PLAN Species Inductrual, Architectural or Premium grade with strength as follows: SOLE PLATE NAIUNGSvmbol Sep [leyPER SHEARWALLeolTGLB 24F-V4 DF/DF 2400/1850 psi 1,800,000 psi SCHEDGLB24F-V8 DF/DF 2400/2400 psi 1,800,000 psi BEAM OR RIM JOIST PER PLAN IOISTSPERNAN BEAM OR RIM JOIST PER PLAN IOLSTS PER PLAN' • BEAM PER PLAN ENSURE 3" MIN. SOLID WOOD MEMBER IBIIGAT -' wHERE ENSURE 3" MIN. SOLID WOOD MEMBER (BLRGAT24"o WHERE ADD SOLID BLKG. OR DBL. JOIST IF REQ'D JOI6T5 AREPARALLELTO GUAR —al ADD SOLID BLKG. OR DBL JOIST IF REQ'D IOISTSARE PARALLELTO I -JOISTS ARE NOTACCEPTABLE (I -JOISTS ARE NOT ACCEPTABLE GUARDRAIq PRE -MANUFACTURED SITE BUILT SOLID SAWN LUMBER STRUCTURAL NOTES SECTION 10 TYPICAL TIES AT GUARDRAIL POSTS 11 POST AT CONCRETE PIER 12 ROSS Engineering Design Inc JOB # 18016 (425) 314-2373 ryan.ross@rossengineer.com B2 BB�T� g�V yi!8 E aas�$9y�� q#ag�s� £G aAw gk'SC°8 V ��3sE8a€b&eo02m 4/25 2019 �eN N. Ro 4'P2 OY WpBy/pros 6 JO If 19 36 q 46411 ,ur pFCIBTEEY'G p'YSJONAL EtAGA ELECTRONICCOPY ORIGINAL ON FILE AT ROSS ENGINEERING CD CV 0 00 01 Q ® V3 0 — H Z O W Q 0 Z W Q W � 0 N a W W � W vJ i Q LU Q N 0, 0 a 0 d z DATE DESIGNED BY RR DRAWN BY RR CHECKED BY RR SHEET: S MAY 13 2019 PRINT DATE-JLi%'1,7120'f 20YB;0.!;Tn':T TYPICAL SHEAR WALL SCHEDULE NUMBER SMD/BLKG.' OF SHEAR WALL' AT SILL PA'T' /SOLE PATE SHEATHED EDGE ADJOINING FRAMING ANCHORTO NAIL/SCREW e SYMBOL SHEATHING SIDES NAILING PANEL EDGES SIZE CONCRETE TO RIM JOIST SHEAR CLIPS SW3(P) 1 8d @ 6" OC 2x 2x 5/8' DIA. AB @ 98,E OC 16d @ 6" OC i6d TOENAIL" d@ 8.� (N SW2(P) SEE 1 Ed @ 6" OC 2x 2X 5/8" DIA. AB @ 48" OC I6d @ 6" OC LTP4 @ 24" OC STRUCT 1 Lid @ 4" OC ' 2x 2x 5/8" DIA. AB 16tl @ 4" OC LTP4 @ 18" OC SW3(P) @ 32" OC NOTES 1 Ed @ 3" OC 3xc 2x 5/8' DIA. AB I6d @ 3" OC LTP4 @ 14" OC SW4(P) @ 24" OC 1 Ed @ 2" OCR 3z 2x 5/8' DIA- AB I6d @ 3" OC LTP4 @ 10" OC SWS(P) @18'OC SW6 2 Bd @ 3" OC 3x 3x 5/8' DIA. Al @ 16" OC NA LTP4 @ 14" OC EACH FACE 10 HEAR WALL �OJ'�. STH pX SW_P NpUX 0"- SHEAR WALPLPER AN HOLD-DOWN ID '\ SHEAR CLIPS PER SHEAR WALL KEY SHEAR WALL KEYSHEAR WALL SCHEDULE EDGE NAILING WHERE APPLICABLE j. SQUASH BLOCKS IFIMPM IOISTSATALLPOSTS AND RIII iII ill III III III IIIII III III N III III II JOIST HANGER HOLD-DOWNS, ALL LEVELS. 11 I TYPICAL TOENAIL PERPAN SEE TYPIAL POST BLKG. _ -- -- --- - _ -- DETAILTYP. Ir _ _TI_ _`Ir--I) TT,-.-TITI-`-IT: rL LI II, 4I H BLKGPERSCHEDATHORIZ._11 41 Id' ANCHOR TYPE HOLD-DOWN J - It _ II _IL PANELJOINTS w/EDGE W/ ANCHOR ROD PER 'II LI T NAILING BOTH SIDES OF i I r STRAP TYPE HOLD-D OWN SCHEDULE PERYP. JI. i( II II ji I. JOINTTYP. 11 1(�, N it IL- ;,jL HOLD-DOWN CENTER 11 It II II' it II• fl 11. IY I II. 11 ON RIM JOIST AT SHEAR WALL SCHEDULE NOTES Ed AT 12" o.c. NAILING ATALL II LI 11. I LI' (- 4 :If UPPER FLOORS TYP. 1. 5HEARWALLSNOTEDA5"5W_" INDICATE "SEGMENTAL SHEAR WALL" PER DETAIL (RIGHT) INTERMEDIATE SUPPORTS II 'll LOCATE VERTICAL PANEL I f( H LII 11• PANEL EDGE NAILING 2. SHEAR WALLS NOTED AS "SW _P"INDIATE"PERFORATED SHEAR WALL" PER DETAIL (RIGHT). APPLY ALL It -'li �� JOINT ON STUD w/EDGE JI IL: II LII; N II TYP. DECK JOISTS PER PAN. EDGE SHEATHING, NAILING AND FRAMING REQUIREMENTS PER SCHEDULE TO THE FULL LENGTH OF SHEAR WALL PANEL EDGE NAILING TYR. NAILING BOTH SIDES OF II IF Llf N ql ALIGN w/FLOOR JOISTS NAILING INCLUDING AREAS ABOVE AND BELOW OPENINGS. JOINT II tl' IT 11- N ;IP qLL AROUNDEL EDGE NAILING CONTAIM JOIST 3. NAILS SHALL BE COMMON OR GALVANIZED BOX. SILL/SOLE PATE W/ I IJ, I` rll. II SHEAR CUP 4. WHERE NAIL SPACING IS LESS THAN 4"oc, STAGGER NAILS ER ANCHORS PER SCHED.7VP. MIN (2)STUDS AT EA CH 11 11 III _ OPENING PER SHEAR 5. ALIGN ALL VERTICAL ADJOINING PANEL EDGES WITH STUD PER SCHEDULE. PROVIDE BLOCKING PER SCHEDULE HOLD-DOWN UNLESS II 11, III SIMPSON DTT2Z EACH END WALL ANCHOR TYPE HOLD-DOWN NOTED OTHERWISE PER AT HORIZONTAL ADJOINING PANEL EDGES. PANEL EDGE NAILING OF DECK AND AT 64"o.c. SCHEDULE 6. AT SW4 ONLY, 3x FRAM I NG MAY BE SUBSTITUTED WITH NAILED TOGETHER W/10d@3"o.c EACH FACE. PER PAN WHERE APPLICABLE. PAN OR POST TYP. WEB STIFFENER EA. JOIST SHEARWALL 7. USE 3"x3"x.223" STEEL PATE WASHERS AT SILL BOLTS. LOCATE EDGE OF WASHER WITHIN Y4"OF EDGE OF SEE SCHEDULE FORROD TYP. ANCHOR SCHEDULE TYP. SHEATHED SIDE OF SILL PATE. HOLE IN WASHER MAY BE DIAGONALLY SLOTTED 1.75" MAX. PER PAN B. IN ADDITION TO SHEAR CLIP SPACING PER SCHEDULE, PROVIDE ONE CLIP EACH END OF SHEAR WALL AT EACH STRAP TYPE HOLD-DOWN REQUIRED ACE OF SHEATHING. SEGMENTAL SHEAR WALL PER PLAN TYP. PERFORATED SHEAR WALL 9. SEE DETAIL (TOP FAR RIGHT) FOR TYPICAL TOENAIL SHEAR WALL SCHEDULE 4 —SOLE PLATE CONNECTION PER SHEAR WALL SCHEDULE —BOUNDARY NAILING PER DIAPHRAGM SCHEDULE NAILSTUDTO BOUNDARY NAILING PER HDR PER TYP. DIAPHRAGM SCHEDULE HEADER DETAIL FLOOR SHTG. A34 EA CONT. SOLID BLOCKING JOIST NAIL SHTG TO HEADER W/ 10d @ 3"o.c. EA WAY HEADER PER PAN ISTA18 EACH FACE SHIMINSIDEFACEAS CANTILEVERED 3 o NEEDED FLOOR JOIST PER (2) ROW516d AT 3" o.c. PAN POST PER PAN BEAM PER PAN w (TOP PATE) 3 za �g u sHOLD-DOWN PER PAN SECTION 5 3° oa 4" MIN ANCHOR BOLTSPER TYP SHEAR WALL SCHEDULE (2 MINIMUM) NEW SHEAR WALL " PER PAN (SHEATHING SHEAR WALL PER MAY BE APPLIED TO PAN SHEAR WALL PER PAN #3 HORIZ TIES @ 8" INSIDE OR OUTSIDE o.c. & (2) AT TOP FACE) SOLE PIATE NEARING PER H. OF EXISTING TINGCSPACING AND CRETENCHDIAMETER PRESSURE RHEA ALL sxEARwquscHEo OF EXISTING CONCRETE ANCHOR PATE PER SHARWALL BOLTS. ADD %" DIA.x5" TITEN HD SCHEDULE. AS NEEDED SO THAT NO SPACE BOLT EMBED =7"MIN. EDGE NAILING lad A76^o.c. y _ TYPICAL STUDS NOT BETWEEN ANCHOR BOLTS EXCEEDS SHEAR WALL PER PAN THE SPACING PER SHEAR WALL SHOWN FOR CARITY EDGE NAILING TO (SHEATHING ON INSIDE FACE) - SCHEDULE. PROVIDE PATE SILL PATE WASHERS PER SHEAR WALL SCHEDULE NOTE 6. BEAM PER PAN EDGE NAILING #4 VERT. EA. END OF STEM TO BOT PATE A WALL AND @ 12"o.c. r / 4 Z �, HOOK INTO FOOTING EXISTING FOUNDATION. CONTRACTOR SHALL VERIFY FOUNDATION WALL PER CONCRETE IS REINFORCED AND NEW FOOTING PER PLAN HOLD-DOWN STRAP PER PLAN �� IN ADEQUATE CONDITION FOR (OUTSIDE FACE) TO DOUBLE STUD LOAD BEARING, IE. FREE OF RUST, SPALUNG AND CRACKS LARGER THAN HAIRLINE CRACKS. O F PAN AND DETAIL 1/Sl PLAN VIEW A06TN G. Ai 48" FOOTING PER PAN I V BEAM PER PM 2xB lNG16d AT6"o.c. "W" PER PAN ADD (3)#4x24" z4" EMBED -- EPDXY DOWEL AT EXISTING FOOTING (2 SIDES) HOLD-DOWN DETAIL 6 NEW SHEAR WALL AT EXISTING FOUNDATION 7 SHEAR WALL AT NEW FOUNDATION $ SECTION 9 SHEAR WALL AT GARAGE DOOR 1 C CSi6 X 48" STRAP AT 48" o.c. TAPERED JOISTS PER PAN FILL ALL NAILHOLE8S. CENTER T48- . (TAPER NOT SHOWN) SHEAR WALL PER PAN FLOOR BOUNDARY NAILING - N JUN BOUNDARY PER DIAPHRAGM SCHED FLOOR BOUNDARY NAILING PER FLOOR BOUNDARY NAIUM FLOOR JOISTS PER PAN - NAILING PER 30d AT6" o.c. DIAPHRAGM SCHED SOLE PATE CONNECTION PER PER DIAPHRAGM SCHEDUL DIAPHRAGM SCHED GUARDRAIL SEE OTHERS SHEAR WALL SCHEDULE ALIGNED PER PAN ALIGNED OVER SHEAR WALL (CON'T. SOLID BLKG. AT SOLE PATE CONNECTION A35 MATCH SHEAR (3)16d rACH STUD PERPENDICULAR FRAMING) PER SHEAR WALL SCHED SOLID CLIP SPACING PER CONT. 2x BLKG. FLOOR BLKG SHEARWALL SCHEDULE EDGE SOLE PATE NAILING SHTG. EDGE NAILING TO ' SOLE PLATE X' CONT.RIM JOIST FLOOR BOUNDARY NAILING FLOOR BOUNDARY NAILING HANGERS PER PLAN TYP PER DIAPHRAGM SCHED - PER DIAPHRAGM SCHED FLOOR 1015T5 PER PAN CONT RIM JOIST CONT RIM BEAM PER PAN - (2) BAYS OF JOIST DECK JOISTS PER PANXBLOCKING AT EACH STRAP EDGE NAILING FLOOR JOIST SHEAR CLIPS SHEAR CLIPS PER - PER PAN BEAM PER PAN PER SHEARWALL SCHED JOISTS PER PAN HANGER PER PAN SHAR WALL SCHED OTTIZ WITH SDS25312 EACH END ' - SHEARWALL (BLKG TO TOP PATE) OF DECK AND AT 54" o.c. SHEAR WALL PER PAN PER PAN SHEAR CLIPS PER BEAM PER PAN (SHEATHING OK AT INSIDE FACE) (INSIDE FACE SHEAR WALL PER PAN EDGE NAILING OK) SHEAR WALL SCHEDULE (TOP PLATE) WALL PER PAN . .. SHEAR WALL PER PAN SECTION 11 TYPICAL SHEAR WALL AT OVERHANG 12 SECTION 13 SHEAR WALL AT CANTILEVERED JOISTS 14 SHEAR WALL AT DECK JOISTS 15 2x BLOCK @ EA BRACE ROOF BOUNDARY NAILING ATTACH W/ (2) 16d ROOF BOUNDARY NAIUNG SHEAR WALL PER PAN PER DIAPHRAGM SCHED EA END PER DIAPHRAGM SCHED _ — - (4)10d TO BLKG ROOF DIAPHRAGM SHTG _ PER STRUCT NOTES SIMPSON NBC AT48" o.C. SOLE PLATE NAILING OBL 2x8 NAILER RIPPED TO 10d AT 4" o.c. PER SHEARWALL SCHED /�:ROOFSHTG -- MATCH 10. ANDLACHPLY LANED TO 2X CONT. BLKG. W/16d AT 4"O.C. DRAG TRUSS PER w/ 16d AT 6" O.C. PAN ALIGNED DECK JOISTS PER PLAN Ross Engineering Design Inc JOB #18016 (425) 314-2373 ryan. ross&OSSengineemom tiwE _m2%mod Qg3`a X3£ nU�995gg�@�8 �gg 8g�8 �s#gf!85�Y5EY g�E 4/25 2019 4, N' Ro 4,R�0T a4ygiNc�, !0 # J 19 36 484t1 �O `P80tSTEa� 9s10RAL ENc'Y ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING 0 Ol Ol z 3 z 1� O W w Q W Z W 1.2 w ® a W W c~ i Q Q W 0 d 2 SW EDGE NAILING TYP ROOOVER SHEAR WALL - F 10d AT 6" ox.. TRU55 EXTEND SHEARWALL CONT.2x BLKG SHTG OVER GABLE- . (VENT PERARCH) END TRUSS TO ROOF DIAPHRAGM SW EDGE NAILING SHEAR CLIPS PER SHEAR TAPERED DECK DTT1Z WITH SD525312 EACH WALL SCHED (BOTTOM Z. BLKG @ 48"o.c. 2x4 BRACE FLOOR JOISTS PER PAN CHORD TO TOP PATE) NAIL TO BRACE AT 48" o.c. 21 BLKG @ 48"o.c. JOISTS PER PAN END OF DECK AND AT 64" FT O.c. NP Hl. CLIP EACH TRUSS W/ (4) SHEAR CLIP PERSHEARWALL FLOOR JOISTS PER PAN A35 BLKG TO AT TOP & GOT SCHED (BOTTOM CHORD TO lOd EA SIDE NAIL FIRST IOISTTO JTOP PATE TOP PLATE) OF BLCK BEAM w/ l6d AT 12" HANGER PER PAN BEAM PER PLAN EDGE NAILING EDGE NAILING TO TOP PLATE SEDGE H ARWALING PER a.c TOP AND BOTTOM HANGERS PER PAN TYP GLUAM BEAM PER PAN -" SHEARWALL PER PAN SHEAR WALL PERPENDICULAR TO TRUSS 16 SHEAR WALL PARALLEL TO TRUSS 17 INTERIOR SHEAR WALL PARALLEL TO TRUSS 1$ SECTION 19 SECTION 20 FILE/ NO. 171202 DATE DESIGNED BY RR DRAWN BY RR CHECKED BY RR SHEET: S2 3 2019 PRINT DAT- 111; 3 23,/i2019,5 pg,=,^.J I W Aff'NNEWA QFIN5•2W CARAC d' MAIN F 11'll� ASEN fiARA( ZE 1 BUILDING SECTION S'3 SCALE: 1/4" =1'-0" 0 o 2ND FLOOR SHEARWALLS SCALE: 1 /8" =1'-0" EXTERIOR WALLS NOT MARKED SHALL BE SW1 HOLDDOWNS CALLED OUT ARE LOCATED AT BASE OF SHEAR WALLS. SEE SHEET SI FOR HOLDDOWN SCHEDULE AND SHEET S2 FOR SHEARWALL SCHEDULE MAIN FLOOR SHEARWALLS SCALE: 1/8" = 1'-0" >. - CL y68 o p U gm®p Lu ryNw Lu m J O Lua t- 4/25 2019 N•Ro 4'�V.04 WAASyJyco� j JO # 19 36 41VA"pop RFOISREEEO �SSIONAL EEO` ELECTRONICCOPY ORIGINAL ON FILE AT ROSS ENGINEERING O CV O 00 z 01 Q O 1n 0 z 0 U o Z W Q W F= Q W W Luuj v~i CIL ® Q Q W_ 04 o d 0 o" 6 z PROJECT NO. 171202 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET: S31 7 MAY 9 3 201 elY tV 'd3 PRINT DATE 5/SI21911b:53 AMAM FOUNDATION NOTES • VERIFY ALL DIMENSIONS AND FIELD CONDITIONS PRIOR TO COMMENCING ANY WORK. • GENERAL CONTRACTOR AND/OR FOUNDATION CONTRACTOR SHALL VERIFY THE LOCATION OF ANCHOR BOLTS AND HOLDOWNS PRIOR TO POURING CONCRETE. • ALL FOOTING SHALL BEAR 18" BELOW UNDISTURBED NATURAL SOIL. FINISHED GRADE SHALL BE NO LESS THAN 12" ABOVE BOTTOM OF FOOTINGS. • TOP OF FOOTING SHALL BE LEVEL. BOTTOM SURFACE OF FOOTING SHALL NOT SLOPE MORE THAN 10%. STEP FOOTING AS NECESSARY TO MAINTAIN MIN. DEPTH OF FOOTING BELOW FINISHED GRADE. • FOUNDATION WALL SHALL EXTEND MINIMUM 6" ABOVE FINISHED GRADE. • ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED. • UNLESS NOTED OTHERWISE OR IN SHEAR WALL SCHEDULE, ALL ANCHOR BOLTS SHALL BEX' dia. x 10"AND EXTEND MINIMUM 7" INTO CONCRETE WITH MINIMUM SPACING OF 48" ON CENTER. EACH ANCHOR BOLT SHALL HAVE A3"x3"x.229" GALVANIZED WASHER. • SEE SHEARWALL& HOLDOWN SCHEDULES FOR SIZE AND PLACEMENT. • CRAWLSPACE ACCESS SHALL BE A MIN. OF 18"x24". OPENINGS THROUGH A PERIMETER WALL SHALL BE NOT LESS THAN 16'SQ4". (R408.4) • PROVIDE A 6 MIL. BLACK VAPOR BARRIER OVER ALL CRAWLSPACE AREAS. (R406.3.2) • PROVIDE 2" SAND OVER 6 MIL BLACK VAPOR BARRIER OVER 4" COMPACTED GRANULAR FILL UNDER ALL CONCRETE SLABS. • PROVIDE TEMPORARY BRACING AS REQUIRED UNTIL ALL PERMANENT CONNECTIONS ARE IN PLACE. • ALL ISOLATED SPREAD FOOTING TO BE 24"x24"xB" REINFORCE FOOTINGS WITH (2) #4 BARS EACH WAY UNLESS NOTED OTHERWISE IN PLAN. • FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE INTERIOR SPACES AND FLOORS BELOW GRADE SHALL BE DAMPPROOFED FROM TOP OF FOOTING TO FINISHED GRADE. (R406.1) • SEE SIMPSON RECOMMENDATIONS FOR. HOLD DOWN PLACEMENT. COORDINATE LOCATIONS WITH DOOR & WINDOW ROUGH FRAMING TO PROVIDE ACCURATE DIMENSION FOR OPENINGS. FOUNDATION PLAN SCALE: 1/4" =1'-0" y J s1i , w 8 4/25 2019 N.Ro WAyylNars R`R ' CTO 9 JO N 19 36 q'go R4'CIP SEE�`�' �SSIORAL ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING N 0 CO Z 1T Op - Z U o Z w Q W 1--2 � Q _ N w w w W cl) ix �C IY Lu ® p Q W (V 0 0 c 0 0 Z PROJECT NO. 171202 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET: S4 MAY f32019 PRINT DATE 5/8/20i9'lr,,6 Ck I Y POST, CAP & BASE SCHEDULE SYM. POST CAP BASE NOTES: P-01 (1)2z— STUD w/(1)TRIMMER (4) led NAIL(DBL TOP PLATE) (4) led NAIL (TOE PLATE) 16d NAILS STAGGERED@ 12" O.C.(8) 18d NAILS STUD TO HEADER P-02 2X_STUD w/(2)TRIMMERS (4) 16d NAIL(DBL TOP PLATE) (4) 1ad NAIL (TOE PLATE) led NAILS STAGGERED@ 1Y D.C.(8) 16d NAILS STUD TO HEADER P-03 (2)2x_TRIMMERS (4) 16d NAIL(HEAOER) (4) led NAIL (TOE PLATE) lad NAILS STAGGERED @12"O.C. P-04 (2)2x_STUDS (4) 16d NAIL(ML. TOP PLATE) (4) 16d NAIL (TOE PLATE) led NAILS STAGGERED@12"O.C. P-05 NOT USED P-06 (3)2x_STUDS (4) lad NAIL(DBL. TOP PLATE) (4) 16d NAIL ITOE PLATE) 16d NAILS STAGGERED @Ir D.C. p-07 PT6x6 HF#2 SIMPSON CCQ OR ECCO PBS66 p-08 PT4%6 HF#2 PC6Z (4) 16d NAIL (TOE PLATE) p-09 PT 4x4 HF#2 EPC4Z PBS44A ` - p-1O 64 DF#2 SIMPSON ECCQ PBS66 P-11 (4) 2z_STUDS (4) 1 Ed NAIL(DBL TOP PLATE) (4) led NAIL ITOE PLATE) led NAILS STAGGERED @ 12" O.C.. P-12 (5) 2 x _ STUDS (4)16d NAIL (DBL. TOP PLATE) (4) led NAIL ITOE PLATE) led NAILS STAGGERED @ 12" O.C. NOTE: SOLID BLOCKING BETWEEN FLOOR@ POINT LOAD BLOCKING TO BE EQUAL TO OR GREATER THEN THE POST ABOVE BEAM SCHEDULE SYM. BEAM SM-01 4x8 DF#2 OR BETTER BM-02 4x10 DF#2 OR BETTER A B BM-03 6x12 PT HF#2 BM-04 3.5NI1.875"PSL I - BM-05 5.25NIC PSL I EXTEND HEADER BM-06 5.5"z12"GLULAM OVER SHEAR) EXTEND HEADER ICI - BM-07 &2V'x11.875" PSL WALL PER 101S2 OVER _ -- OV.E.R� BSHEAR 9 BM-08 33..55""xz1120".5G"LGULLUALM WALL PER 10/S2 REPLACE EXISTING BM-09 — (11EM— BM-10 6.7S'x9'GLULAM - HEADIER — BM-11 PT4%B HF720RA BETT ER ---- 4—_—_— B-� HA NGER SCHEDULE SYM. HANGER IiI P.T. 111J EXISTING STICK FRAMED ROOF TO REMAIN H-01 ITS2.37/11.88 13, -;+- - H-oz Luz1o/Lcz10 ii `SZ iil N BM— 4 Db I T-O" H-03 IUS2.37H1.88 CANT II I i'j 19 _.'.o♦ H-04 HWOFFSET, H=11.675" S2 H-05 HUG48 MAX H-06 HU0412 MAX I ' n l I iij I Q H-07 HGUS6.88/10 "_`..=_7 ��'.__ _= S OC___ _.i; ♦ III y' REPLACE EXIST NO HEADER i„ NOTE: HANGERS NOT CALLED OUT IN ROOF ,, ti �i,l O PLAN SHALL BE PROVIDED BY TRUBS 6`- ATTACH RIM w/SDS25312 AT _---_ ENGINEER _—_—_---_ _—_—_---_—' —---_---_—_---_— V' o.c. TOP AND BOTTdM !i I BM-04 B —04 3 .. - j j(2)TS22 NO CALLOUTS . - SDrr'GOF'P i02s 4 I I A o SHALL BE n io ....f., m I j'............. o :.... O„♦ d j - HEADER: BM-01 3 ? ! m `�� COLUMN: P-01 (ea. side) S7 o m o z! f 1 2 "ro LEGEND m I I i TYPICAL STRAPS (2) T522 Og i CAN'T /TM92I BM 0 WALLS UNDER 5 - — —--------------------- ___-------------- ♦O IN -FILL EXISTING A (2) HDW BEAM TO POST ... .... WALLS/ FIXTURES OVER g ti ♦1� BEAM 8 POST FACE FLUSH lz p2 ' I HEADERS & BEAMS ____ j — —_ —_ .-.—_--_—_—------- FLOOR PERIMETER • _ _ __ _j, ♦ M-0 I M 0 O FLOORJOISTS '--i-'i--- Ilk 2 CONCRETE --- LANDING JOISTS w i j j LANDING&STEPS —STAIR STRINGERS I I TOG RgC. PER --- EXISTING ' I 19 I I i I 1875 eCl a 00.118 I I I ` m 6"Ol. 2) P.T. 4> 12 STAI m i I I I I I I I _ 4 - I j - ' "ol 3 -- _.._..... - ' 2 _ - ---------- r P.T. zt J ISTS A 18 - ♦o j o f I � I ♦ I , BM 03 �i j. M- i ; I I ------------ c--------- MAIN FLOOR FRAMING SCALE: 1/4" = 1'-13" FLOOR TRUSS NOTE: THIS LAYOUT IS FOR SCHEMATIC PURPOSES ONLY. REFER TO TRUSS FRAMING PLANS PER MANUFACTURER AND PREPARED BY A LICENSED TRUSS ENGINEER. ` V w Eg� C 4/25 2019 qP� N • Ro 4 OE TA3yIys'S' �t4 � CTo y Jo It 19 36 A'Fo 'P#'CISTIEE� �SSIONALBN ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING N CD 00 ol Z Q O0 � z '.ICI W O Q Z Lu W W 1= 0 LLJ Q _ W N � W T~i> c se Lou ® W Q Q = o' DESIGNED BY TL DRAWN BY TL&RM CHECKED BY TL SHEET: 51 1*7�;Oli ' 3 MAY 13 c )19, PRINT DATE �• m "N" 54"A' 7—MIT 5/8/2OQj1P:5,�7---dki,•2,;; ;Nbs ROOF PLAN NOTES • SEE DESIGN LOADS AND/OR STRUCTURAL NOTES FOR GROUND AND ROOF SNOW LOADS. • FOR MANUFACTUREDED TRUSS ROOFS: ROOF PLAN IS FOR SCHEMATIC PURPOSES ONLY. ACTUAL ROOF PLAN TO BE DESIGNED AND ENGINEERED BY A LICENSED TRUSS' ENGINEER. RAFTER FRAMING PER PLAN. • TRUSS LAYOUT TO BE REVIEWED AND APPROVED BYTHE TRUSS MANUFACTURER PRIOR TO CONSTRUCTION. SHADED AREAS INDICATE OVER -FRAMING • LOCATE DOWNSPOUTS PER SITE CONDITIONS AND PER GENERAL CONTRACTOR. • INSTALLATION OF ALL ROOFING AND WALL FLASHING SHALL BE TO INDUSTRY STANDARDS AND IN COMPLIANCE WITH CURRENT CODES. • PROVIDE CONTINUOUS ALUMINUM GUTTERS ON FASCIA AS SPECIFIED IN DETAILS. • SKYLIGHT SIZES, IF ANY, ARE APPROXIMATE. CONTRACTOR TO VERIFY ACTUAL ROUGH OPENING SIZE PER MANUFACTURER SPECIFICATIONS. • PROVIDE SOLID BLOCKING OVER ALL SUPPORTS. • PROVIDE MIN. 22"x30" ATTIC ACCESS WITH APPROVED WEATHERSTRIPPING. IF ACCESS IS IN A GARAGE, A SELF CLOSING MECHANISM MUST BE INCORPORATED. . • 16d @ 8"o.a END TRUSS TO TOP PLATES. (TYPICAL AT ALL GABLE ENDS) • ATTICS WHERE THE MAX. CLEAR HEIGHT BETWEEN JOIST AND RAFTERS IS MORE THAN 42, OR WHERE THERE ARE - TWO OR MORE ADJACENT TRUSSES WITH THE SAME WEB CONFIGURATION CAPABLE OF CONTAINING A RECTANGLE 42" HIGH BY 24" WIDE OR GREATER, MUST BE CONSIDERED ATTIC WITH LIMITED STORAGE. ATTIC SPACE SERVED BY A FIXED STAIR SHALL BE - DESIGNED TO SUPPORT THE MIN. LIVE LOAD FOR SLEEPING X,\ ROOMS. ATTIC VENTILATION CALCULATIONS ATTIC VENTILATION (R806.1 8 806.2) ' PROVIDE 1 SQ. FT. OF ATTIC VENTILATIOWFOR EACH 150 SO. FT. OF ATTIC AREA. EXCEPTION: PROVIDE 1 SQ. FT. OF ATTIC VENTILATION FOR EACH 300 SQ. FT. OF ATTIC SPACE WHEN NOT LESS THAN 40% AND NOT MORE THAN 50% OF THE REQUIRED VENTILATION AREA IS PROVIDED BY VENTILATORS LOCATED WITHIN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED NOT MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACED MEASURED VERTICALLY WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. WHERE THE LOCATION OF WALL OR ROOF FRAMING MEMBERS CONFLICTS WITH THE INSTALLATION OF UPPER VENTILATORS, INSTALLATION OF MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE SHALL BE PERMITTED. PROVIDE A COMBINATION OF ROOF JACKS OR CONTINUOUS RIDGE VENTING ALONG WITH EAVE VENTS. AF60 JACK VENTS =. 333 SQ. FT. NET FREE AREA. EAVE BIRD BLOCKS =.074 50. FT. NET FREE AREA. CORAVENT V300 =.094 SO. FT. NET FREE AREA PER L.F. ROOF ROOF AREA = 864 $0. FT. / 300 = 2.88 SQ. FT. 12 =1.44 SQ. FT OF REQUIRED VENTING IN BOTH UPPER 50% OF ROOF AND IN LOWER 50%OF ROOF. IN UPPER 50%OF ROOF TOTAL SQ. FT. REQUIRED / .333 =5AF50 JACKVENTS. ' IN LOWER 50%OF ROOF TOTAL SQ. FT. REQUIRED /.074 = 20 EAVE BIRD BLOCKS POST, CAP & BASE SCHEDULE POST CAP BASE (1)2x_STUD w/(1)TRIMMER (4) 16d NAIL (DEL. TOP PIATE) (4) 16d NAIL ROE PLTE) 16d NAILS STAGG 2x-STUD w/(2)TRIM MERS (4) 16d NAIL(DBL. TOP PLATE) (4) 16d NAIL ITOE PLATE) 16d NAILS STAGG (2) 2x_TRIMMERS (4) 16d NAIL (HEADER) (4)16d NAIL TTCE PLATE) 16d NAILS STAGG (2) 2x_ STUDS (4)16d NAIL (DBL. TOP PLATE) (4)16d NAIL (TOE PLATE) 16d NAILS STAGG NOT USED (3) 2x-STUDS (4)16d NAIL (DBL. TOP PLATE) (4)16d NAIL (TOE PLATE) 16d NAILS STAGG PT 6.6 HF#2 SIMPSON CCO OR ECCO PBS68 PT 4X6 HF#2 PC6Z (4) 16d NAIL (TOE PLATE) PT4x4 HF#2 EPC4Z PBS44A 6x6 DF#2 SIMPSON ECCO PBS66 (4) 2 x_ STUDS (4)16d NAIL (DBL. TOP PLATE) (4)16d NAIL (TOE PLATE) 1Ed NAILS STAGG (5) 2X_STUDS (4) 18d NAIL(WL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGG SOLID BLOCKING BETWEEN FLOOR @ POINT LOAD BLOCKING TO BE EQUAL TO OR GREATER THEN THE POST ABOVE ROOF PLAN SCALE: 1X' =1'-0" FOR SCHEMATIC PURPOSES ONLY. REFER TO TRUSS FRAMING PLANS PER MANUFACTURER AND PREPARED BY A LICENSED TRUSS ENGINEER. C BEAM SCHEDULE BEAM A 48 DF#2 OR BETTER )2 4.10 DF#2 OR BETTER )3 6x12 PT HF42 )4 3.5"xl 1.875"PSL 55 5.25M4" PSL )6 5.5"x12"GLULAM )7 5.25"A 1.875"PSL )8 3.5"MZ'GLULAM 39 . 3.5"x10.5" GLULAM 10 6,75N9"GLULAM 11 PT 08 HF#2 OR BETTER HANGER SCHEDULE HANGER i ITS2.37/11.88 2 LU210 ILUC210 3 IUS2.37/11.88 4 HW OFFSET H=11.875" 5 HUG48 MAX 6 HUC412 MAX 7 HGUS8.88/10 HANGERS NOT CALLED OUT IN ROOF PLAN SHALL BE PROVIDED BY TRUSS ALL ROOF FRAMING MEMBERS TO BE MANUFACTURED TRUSSES @ 24" O.C. (U.N.O.) NO CALLOUTS SHALL HEADER: BM-01 COLUMN: P-01 (ea. side) LEGEND TRUSSES ---... OVER FRAMING ;'�� WALLS UNDER HEADERS 8 BEAMS ROOF LINES EXISTING sgEs 'Wi=9s 6 Sp�B $ Ilia gs 8 e a 4/25 2019 qAN N . Ro 4,R%0Y TA3ylycJl Ro 4 Ao Jo # 19 36 Ado Rd0T464111 t� JONALG\ ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING O N O Z CO 01 Q O IN IN H U o Q Z Q W W Q H= W W Q W t/J `'w i � Q W Q Q = N O, DESIGNED BY TL DRAWN BY TL 8 RM CHECKED BY TL SHEET: s6l b, FrF�' p� MAY 13 20 PRINT DATE 3/4" T&G PLY OR EQUIV. SUB -FLOOR GLUED & NAILED TO ROOFING PER ELEVATIONS W 30 #fAN'TFLOOR PER PLA JOISTS. 1" AIR SPACE wl CARDBOARD FELT OVER %s APA _ _ _ FRAMING MEMBERS BELOW ROOF —' --H PLY OR EQUIV. SUB -FLOOR BAFFLE. EXTEND 24'ABOVE RATED 24/16 SHEATHING ON i SHEATHING AS PER PLAN GLUED & NAILED TO - INSULATION MANUF. TRUSSES PER PLAN FLOOR JOISTS. MIN.IN BLOCK BETWEEN TYP. WALL r3l4"T&G n FRAMING MEMBERS wl (2)16d I ASSUMBLY JOISTS PER PLAN VENT BLOCKS w/(3)2'tlia. I I I NAILS EA. SIDE WIRE SCREENED VENT 2x6VALLEY BOARD w/NAILS HOLES @ EA. BLOCK INTO INTO EA. FRAMING MEMBER CONT. ALUM. GUTTER BELOW ' ON FASCIA BOARD R-49 BATT OR I I I I PER ELEVATIONS BLOWN INSUL. (HEATED AREAS 2x4 RAFTERS @24"O.C. BRACED ONLY) I I I DOWN TO FRAMING MEMBER "CEILING GWB I I I BELOW @48"O.C. RJO BATT INSULATION - X'CEILING G.W.B. I I I I I I OVERHANG SOFFIT PER OWNER/ BUILDER INSTALL SHEETROCK BACKING (2) 2x6 TOP PLATES PER PLAN STAGGER JOINT MIN. 48"O.C. I I I I I I SOLID BLOCKING NEEDED E N AS ASDE D FOR PARALLEL JOISTS. PLATES' 2x6 RIDGE BOARD STAGGER JOINT MIN. 48"O.C. TYP. WALL ASSEMBLY I I I I I SEE TYP. ASSEMBLY _ FOR ROOF TO BEAM ASSEMBLY BEAM REPLACES TYP. WALL ASSEMBLY TYPICAL ROOF ASSEMBLY 2x_ ROOF OVER FRAMING o/ EXTERIOR BEARING WALL (AN'T SCALE: 31/4" = l'-0" 2'-0° a"T&G APA48124 RATED SHEATHING NOTE: GLUED & NAILED TO 1. ALL DECKING MATERIAL SHALL FLOOR JOISTS CONFORM w/ I.R.C. 8 LOCAL TYP. ASSEMBLY CODES. Y 2. NAIL ALL DECKING OR SHEATHING o RAIL PER BUILDER ` TO JOISTS wl RING SHANKED HOT o PROVIDE CANT STRIP AND DIPPED GALV. NAILS. FLASHING 3. ALL RAILING AND PANEL N „ FLOOR RIM OR BEAM PER PLAN SYSTEMS INSTALLED PER — FLOOR JOISTS PER PLAN FLOOR JOISTS IRC AND MFG. SPECS. TO j FLOOR JOIST PER PLAN RIPPED FOR SLOPE PER PLANS MEET MIN. 200# POINT LOAD m ¢ WATERPROOFING MEMBRANE • DOUBLE TOP PLATES LOAD. ALL OPENINGS _ OVERACX CROSS BANDED - STAGGER JOINTS MIN. 48"O.C. SHALL BE NO GREATER THAN PLWC SHEATHING SOLID BLOCKING OVER BEARING TOALLOWA4"SPHERETO z — — PASS THROUGH. PITCH PER PLAN (MIN.% PEA RFOOT BEARING WALL PER PLAN — y FLASHING TRIM PER BUILDER - HANGER PER SCHEDULE • — — — —OR— — — RIM JOIST x_ LEDGER W #14 WOOD SCREWS @ -. 5"o.c. STAGGERED 15"T 1f-9y" DTTiZ EACH END &12'-0" O.C. BEAM PER PLAN 1111 TYP. ASSEMBLY - CEILING PER BUILDER LRBR� BEAM PER PLAN TAPERED RAFTERS PER PLAN JOISTS OVER BEARING ED DECK TO RIM JOISTS MINIMAL SLOPED DECK 0 @RAIL �)S-AALEL'4' SCALE: 3/4" = 1'A" 3= 1'-0" SCALE:.1= T-W BEAM PER PLAN CAP PER SCHEDULE BEARING WALL OR POST PER SCHEDULE ' N POST PER SCHEDULE NEW FOOTING PER SCHEDULE CUT AND REMOVE EXISTING CONCRETE > r-o" .25'-a'• 2'-0" SLAB 12" dia. CONCRETE 11�LR - - EXISTING CONCRETE SLAB EXISTING CONCRETE SLAB SONG TUBE TO GRADE BASE PER SCHEDULE FINISHED GRADE (3)#4 BARS ~ I<II I FOOTING & REINFORCING • ...i �.. �I. PER SCHEDULE. BAR PER SCHEDULE— w zw FOOTING o PER BEARING SOIL o �+ SCHEDULE d '� w a PER PLAN 9y", 7T-W FOOTING @ EXISTING SLAB s OTING AND POST 2'-0' 23J 2-0" �LE "D" SCALE: 3/4" =1'-0" 4/25 2019 q0x N • Ro W93glyc �P RO a To JO # 19 36 484ll �op yb'OISRBR�# �4� ySS[ORAL Lp0` ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING O (\I O OD Z ol O 0 — z W Q o Lu Z W Q W F= Q Q W W W v> Y Q ® U Q W C4 d- Q d C 0 c O 6 z PROJECT NO. 1 171202 DESIGNED BY TL DRAWN BY TL&RM CHECKEDBY TL. SHEET: S7 MAY s 1n�s I PRINT DATE