Loading...
BLD2021-0772_Manufacturer_Specifications_and_Installation_Instructions_6.7.2021_1.11.10_PM_2235507Job Name: System Reference: �allllllllllllllllllllllllllo�, `\ ! � �Illlllllllllllllllllllllllllllllllll��i ulmmimwmmnnnnumm�u� �Il�����iiillllllllllllllliiilllllllhpfi GENERAL FEATURES • Variable speed INVERTER -driven compressor • Energy Star° certified' (non -ducted) • M-NET connection through outdoor unit • Quiet outdoor unit operation as low as 50 dB(A) • New Intelligent Power Module (IPM) for reduced power loss • Selectable thermal lockout/restart function • Optional base pan heater • High pressure switch for additional protection • Thermal differential of +/-1 ° F from setpoint 'ENERGY STAR products are third -party certified by an EPA -recognized Certification Body. Date: Specifications are subject to change without notice. © 2018 Mitsubishi Electric US, Inc. ModelIndoor-. Cooling*1 Outdoor Maximum Capacity Btu/h Ducted 20,000 Rated Capacity Btu/h 18,000 19,000 20,000 Minimum Capacity Btu/h 5,700 Maximum Power Input W 2,245 Rated Power Input W 1,417 1,709 2,000 Power Factor % 98.7 99.3 99.9 Heating at 47' F*2 Maximum Capacity Btu/h 25,000 Rated Capacity Btu/h 22,000 Minimum Capacity Btu/h 7,400 Maximum Power Input W 2,455 Rated Power Input W 1,641 1,706 1,771 Power Factor % 96.2 97.9 99.6 Heating at 17' F *3 Maximum Capacity Btu/h 15,500 15,000 14,500 Rated Capacity Btu/h 12,500 13,000 13,500 Maximum Power Input W 1,750 1,780 1,810 Rated Power Input W 1,300 1,325 1,350 Heating at 5° F *4 Maximum Capacity Btu/h 11,100 11,000 10,900 Maximum Power Input W 1,600 1,625 1,650 Efficiency SEER 20.00 18.00 16.00 EER *1 12.70 11.35 10.00 HSPF (IV) 10.00 9.65 9.30 COP at 47* F *2 3.93 3.78 3.64 COP at 17' F *3 2.82 2.87 2.93 ENERGY STAR® Certified YES NO NO Electrical Voltage, Phase, Frequency 208 / 230V, 1-phase, 60 Hz Guaranteed Voltage Range V AC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 V AC 208V / 230 Voltage: Indoor - Outdoor, S2-S3 V DC 12-24 Voltage: Indoor - Remote controller V DC 24 Recommended Fuse/Breaker Size A 20 Specifications are subject to change without notice. © 2018 Mitsubishi Electric US, Inc. Recommended AWG XW - Outdoor) ireMCA AWG14 Outdoor unit A 17.2 Fan Motor Full Load Amperage A 1.77 Fan Motor Output W 64 Airflow Rate CFM 1,342 / 1,458 Refrigerant Control Liner Expansion Valve Defrost Method Reverse Cycle Heat Exchanger Type Plate fin coil Sound Pressure Level, Cooling*1 dB(A) 50 Sound Pressure Level, Heating*2 dB(A) 54 Twin Rotary type Compressor Type Compressor Model SNB140FQUH2T Compressor Motor Output kW 1.5 Compressor Rated Load Amps A 10.7 Compressor Locked Rotor Amps A 15.5 Compressor Oil Type H Charge oz. NEO22 / 20.3 External Finish Color Munsell 3.OY 7.8/1.1 Base Pan Heater Optional Unit Dimensions W: In. [mm] 33-1/16 [840] D: In. [mm] 13 [330] H: In. [mm] 27-15/16 [710] Package Dimensions W: In. [mm] 40 (1,010] D: In. [mm] 18-1/2 [470] H: In. [mm] 33-1/2 [850] Unit Weight Lbs. [kg] 126 [57] Package Weight Lbs. [kg] 147 [67] Outdoor unit operating temperature range Cooling Intake Air Temp (Maximum / Minimum) OF 14 to 115 Heating Intake Air Temp (Maximum /Minimum) OF 5 to 75 Thermal Lock -out / Re -start Temperatures OF Cooling: 10.4 / 14 Heating: 1.5 / 5 W Specifications are subject to change without notice. © 2018 Mitsubishi Electric US, Inc. Outdoor ModelIndoor Ducted Type R410A Refrigerant Charge Lbs., Oz. 3,15 Maximum Number of Connected IDU 2 Minimum Number of Connected IDU 2 Indoor unit connection Maximum connected capacity Btu/h 24,000 Minimum connected capacity Btu/h 12,000 Gas Pipe Size O.D. (Flared) In. [mm] 3/8 [9.52] Liquid Pipe Size O.D. (Flared) In. [mm] 1/4 [6.35] Total Piping Length Ft. [m] 164 [50] Maximum Height Difference, ODU above IDU Ft. [m] 33 [10] Piping Maximum Height Difference, ODU below IDU 49 [15] Ft. [m] Ft. [m] 82 [25] Farthest Piping Length from ODU to IDU Maximum Number of Bends 50 AHRI Rated *1 Cooling (Indoor // Outdoor) OF 80OF DB, 670F WB // 950F DB, 750F WB Conditions (Rated *2 Heating at 470F (Indoor H Outdoor) OF 70OF DB, 60OF WB H 470F DB, 430F WB data is determined at a fixed *3 Heating at 17°F (Indoor // Outdoor) OF 70°F DB, 60OF WB // 17°F DB, 15OF WB compressor speed) Conditions *4 Heating at 5°F (Indoor // Outdoor) OF 70oF DB, 60°F WB // -4°F DB, -5°F WB For reference to connected capacity charts, please refer MXZ-2C20NA2-U1 Operational Performance. Notes: Specifications are subject to change without notice. © 2018 Mitsubishi Electric US, Inc. Port Adapter size: 3/8" x 5/8" ❑ PAC-SG76RJ-E Port Adapter size: 1/4" x 3/8" ❑ PAC-493PI Joint Pipe Port Adapter size: 3/8" X 1/2" ❑ MAC-A454JP-E Port Adapter size: 1/2" X 3/8" Port Adapter size: 1/2" X 5/8" Air Discharge Guide Base Pan Heater Control Cable ❑ MAC-A455JP-E ❑ MAC-A456JP-E ❑ MAC-856SG ❑ PAC-646BH-E ❑ CW162S 3-pole Disconnect ❑ TAZ-MS303 M-NET Adapter ❑ PAC-IF01 MNT-E Wall Mounting Bracket (Powder -coated Steel) ❑ QSWB2000M-1 Wall Mounting Bracket (316 Series Stainless Steel) ❑ QSWBSS Outdoor Unit Mounting Pad 24" x 42" x 3" ❑ ULTRILITE2 MiniSplit Mounting Stand -Dual Fan models - 12" ❑ QSMS1202M MiniSplit Mounting Stand -Dual Fan models - 18" ❑ QSMS1802M MiniSplit Mounting Stand -Dual Fan models - 24" ❑ QSMS2402M 1/4 x 1/2 x 15' / 1/2" Lineset (Twin -Tube Insulation) ❑ MLS141212T-15 1/4 x 1/2 x 30' / 1/2" Lineset (Twin -Tube Insulation) ❑ MLS141212T-30 1/4 x 1/2 x 50' / 1/2" Lineset (Twin -Tube Insulation) ❑ MLS141212T-50 1/4 x 1/2 x 65' / 1/2" Lineset (Twin -Tube Insulation) ❑ MLS141212T-65 1/4 x 1/2 x 100' / 1/2" Lineset (Twin -Tube Insulation) ❑ MLS141212T-100 Diamondback Linesets*l 3/8 x 5/8 x 10' / 1/2" Lineset () Twin -Tube Insulation 3/8 x 5/8 x 15' / 112" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-10 ❑ MPLS385812T-15 3/8 x 5/8 x 30' / 1/2" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-30 3/8 x 5/8 x 50' / 1/2" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-50 3/8 x 5/8 x 65' / 1/2" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-65 3/8 x 5/8 x 100' / 1/2" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-100 "1 Linesets are indoor unit specific and will be listed in the IDU information - the Joint Pipe adaptors are used in this application Specifications are subject to change without notice. © 2018 Mitsubishi Electric US, Inc. Handle Rio 1.FREE SPACE E E E 3-15/16' or more p 0 8 3-15/16' or more 13-25/32' or more FORM# MXZ-2C20NA2 - 201805 Unit: inch (mm) l GAS H (a.35 )FLA E I GA53I6'(eg.51�FLARE ® k rounding terminal MITSUBISHI kn�nnea ELECTRIC COOLING & HEATING 1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com ETA us Intertek Specifications are subject to change without notice. © 2018 Mitsubishi Electric US, Inc.