Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2021-0804_Manufacturer_Specifications_and_Installation_Instructions_6.11.2021_10.21.15_AM_2244808
AIR CONDITIONERS LE---7 NNOX RES/DENT/AL PROD UC T SPEC/FICA TONS ELITE SERIES LENNOX QUANTUM" COIL MODEL NUMBER IDENTIFICATION EL16XC1 ELITE° Series R-410A - 60 Hz Bulletin No. 210833 October 2020 Supersedes July 2020 SEER up to 17.85 1.5 to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh EL16XC1-036-230A01 Product Tier ----------------- EL = Elite' Series Nominal SEER ----------; ------ Ratings Revision Level 16 = 16 SEER ' 9 RefrigerantType-------- Voltage X = R 410A 230 - 208/230V 1 phase 60hz Unit Type ------ ; ------ Nominal Cooling Capacity C = Air Conditioner (Condenser) 018 = 1.5 tons 024 = 2 tons Cooling Stages ---- 030 = 2.5 tons 036 = 3 tons 1 = Single Stage Compressor ' 041 = 3.5 tons 042 = 3.5 tons Regional Standards --- 047 = 4 tons — (dash) = All Regions 048 = 4 tons S = Southeast and North Regions 060 = 5 tons aft 19 C cy O U U U Q N O O (a W _ C N N O C E U a Cu a L) U c y co > CD O Cn C U v �j Q Cu F J of cv o co ow E c c U E n pco m c U a V U 2 a� C) > 0) ca � o > C) Or w 2 Cn o: CV M L-6 1.6 I� 00 M M O I- M (71 ON I- ON r- . . . . . cc . cc . Cl. N COcc M C- CV U Cn Cll . CU L a) (n i--� . C .L p a) 0) o y o o p D co p� cn COO� 0 0) C C-) +° o v n H p C:c Q Co u Z ( � L co c0 U i LLI O O +J C N .L +J = co C-0� p O N V �_ a i i N Cll N C1 OQ L) E LU LL I L O C/5 C) I— H V APPROVALS AND WARRANTY APPROVALS • AHRI Standard 210/240 certified • AHRI Certified system match -ups and expanded ratings, visit www.LennoxPros.com • ENERGY STAR° Certified (certain units) • Sound rated to AHRI Standard 270-2008 test conditions • Tested in Lennox' Research Laboratory environmental test room • Rated According to U.S. Department of Energy (DOE) test procedures • Region specific models meet the minimum efficiency requirements for U.S. DOE Federal Regional Standards in that area • Unit and components ETL, NEC and CEC bonded for grounding to meet safety standards for servicing • ETL certified (U.S. and Canada) • ISO 9001 Registered Manufacturing Quality System WARRANTY • Compressor: • Limited ten years in residential installations • Limited five years in non-residential installations • All other covered components: • Limited five years in residential installations • Limited one year in non-residential installations NOTE - Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details. FEATURES APPLICATIONS • 1.5 through 5 ton • Sound levels as low as 71 dBA • Single-phase power supply • Vertical air discharge • Applicable to indoor air handlers or gas furnaces with indoor add -on coils • Shipped completely factory assembled, piped and wired • Factory test operated REFRIGERATION SYSTEM R-410A Refrigerant • Non -chlorine, ozone friendly • Unit is factory pre -charged 0 Outdoor Coil Fan • Direct drive fan • Vertical air discharge • Totally enclosed fan motor • Sleeve bearings • Inherently protected • PVC (polyvinyl chloride) coated steel fan guard © Quantum" Coil • Lennox designed and fabricated coil • Enhanced aluminum alloy tube/enhanced fin coil • Superior corrosion resistance • Ripple -edged aluminum fins • Aluminum tube construction • Lanced fins for maximum fin surface exposure • Fin collars grip tubing for maximum contact area • Flared shoulder tubing connections • Factory tested under high pressure • Entire coil is accessible for cleaning ® High Capacity Liquid Line Drier • Factory installed in the liquid line • Drier traps moisture or dirt • 100% molecular -sieve, bead type, bi-flow drier ® High Pressure Switch • Protects the system from high pressure conditions • Automatic reset Discharge Thermostat • Factory installed on the discharge line of the compressor • SPST • Automatic reset • Removes power to the compressor when discharge temperature exceeds the factory setting of 220OF EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 3 FEATURES REFRIGERATION SYSTEM (continued) Refrigerant Flow Control • Units applicable to RFCIV METERING SYSTEM expansion valve ORIFICE BODY RFCIV systems or RFC (On Coll) "BULLET systems when / ORIFICE matched with specific indoor coils O-RING LIQUID LINE RFCIV: OO LIQUID / • Accurately meters LINE SCREEN refrigerant in SEAL • system NUT SWEAT Refrigerant control CONNECTION is accomplished by exact sizing of refrigerant metering orifice • The principle involves matching indoor coil with proper bore size of orifice in metering device • Equalizes pressure shortly after compressor stops, unit starts unloaded • Eliminates need for additional controls • Furnished with air conditioner Optional Accessories Expansion Valve Kits • Field installed on certain indoor units • See TXV/Orifice Usage table • Chatleff-style fitting Freezestat • Senses suction line temperature • Cycles compressor off when suction line temperature falls below it's setpoint • Opens at 29°F and closes at 58°F • Installs on or near the discharge line of the evaporator or on the suction line Loss of Charge Switch Kit • Protects compressor from damage from low refrigerant charge conditions • SPST, normally -closed • Automatic reset Refrigerant Line Kits • Refrigerant lines are shipped refrigeration clean • Lines are cleaned, dried, pressurized and sealed at factory • Suction line fully insulated • Lines are stubbed at both ends NOTE - Not available for -060 models. Must be field fabricated. CnMPRES-ROR © Scroll Compressor • High efficiency with uniform suction flow • Constant discharge flow, high volumetric efficiency and quiet operation • Low gas pulses during compression reduces operational sound levels • Compressor motor is internally protected from excessive current and temperature • Muffler in discharge line reduces operating sound levels • Compressor is installed in the unit on resilient rubber mounts for vibration free operation Scroll Compressor Operation • Two involute spiral scrolls matched together generate a series of crescent -shaped gas pockets between them • During compression, one scroll remains stationary while the other scroll orbits around it • Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates • As the spiral movement continues, gas pockets are pushed to the center of the scrolls. Volume between the pockets is simultaneously reduced • When the pocket reaches the center, gas is now at high pressure and is forced out of a port located in the center of the fixed scrolls • During compression, several pockets are compressed simultaneously resulting in a smooth continuous compression cycle • Continuous flank contact, maintained by centrifugal force, minimizes gas leakage and maximizes efficiency • Compressor is tolerant to the effects of slugging and contaminants. If this occurs, scrolls separate, allowing liquid or contaminants to be worked toward the center and discharged Compressor Crankcase Heater (060 Models) • Protects against refrigerant migration that can occur during low ambient operation • Factory Installed Compressor Sound Dampening System • Polyethylene compressor • 2 inch thick batt fiberglass insulation • All open edges sealed with one -inch wide hook and loop fastening tape EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 4 FEATURES COMPRESSOR (continued) Optional Accessories Compressor Crankcase Heater (018 thru 048 models) • Protects against refrigerant migration that can occur during low ambient operation Compressor Hard Start Kit • Single-phase units are equipped with a PSC compressor motor • This type of motor normally doesn't need a potential relay and start capacitor • For conditions such as low voltage kit may be required to increase the compressor starting torque Compressor Low Ambient Cut -Off Switch • Non-adjustable switch (low ambient cut-out) prevents compressor operation when outdoor temperature is below 357 CONTROLS Optional Accessories iComfort® E30 Smart Wi-Fi Thermostat • Wi-Fi enabled, electronic 7-day, universal, multi -stage, programmable, touchscreen thermostat • 3 Heat/2 Cool • Auto -changeover • Controls dehumidification during cooling mode and humidification during heating mode • Offers enhanced capabilities including humidification / dehumidification / dewpoint measurement and control, Humiditrol° control, and equipment maintenance reminders • Easy to read 7 in. color touchscreen (measured diagonally) • LCD display with backlight shows the current and set temperature, time, inside relative humidity, system status (operating mode and schedules) and outside temperature (optional outdoor sensor required) • Smooth Setback Recovery starts system early to achieve setpoint at start of program period • Compressor short -cycle protection (5 minutes) • Up to four separate schedules are available plus Schedule IQ'" • One -Touch Away Mode - A quick and easy way to set the cooling and heating setpoints while away • Smart AwayTM - Uses geo-fencing technology to determine when the homeowner is within a predetermined distance from the home to operate the system when leaving, away and arriving • Wi-Fi remote monitoring and adjustment through a home wireless network for desktop PCs, laptops and apps for smartphones or tablets • Smart home automation compatible with Apple HomeKitTM, Amazon Alexa°, Google Assistant and IFTTT • Service Dashboard features online real-time monitoring of installed iComfort° thermostats • High Definition Color Display with Subbase, Smart Hub Controller, wallplate (for retrofit installations) furnished for easy installation • See the iComfort° E30 Smart Wi-Fi Thermostat Product Specifications bulletin for more information Remote Outdoor Temperature Sensor • Used with the iComfort° E30 Smart Wi-Fi Thermostat • When installed outdoors, sensor allows thermostat to display outdoor temperature • Sensor is auto -detected when connected to thermostat NOTE - Sensor is required for the Enhanced Dehumidification Accessory (EDA). Thermostat • Thermostat is not furnished with unit • See Lennox Price Book for selection Indoor Blower Off Delay Relay • Delays the indoor blower -off time during the cooling cycle Low Ambient Kit • Air conditioners can operate down to 45°F outdoor air temperature without additional controls • Allows unit to operate properly down to 30°F NOTE - Crankcase heater and freezestat should be installed on compressors equipped with a low ambient kit. NOTE - A compressor lock -out thermostat should be added to terminate compressor operation below recommended operation conditions. Compressor Timed -Off Control • Prevents compressor short -cycling • Allows time for suction and discharge pressure to equalize • Permits compressor start-up in an unloaded condition • Automatic reset with 5 minute delay between compressor shut-off and start-up EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 5 FEATURES CABINET 0 • Heavy -gauge steel construction • Pre -painted cabinet finish • Louvered heavy gauge steel panels surround unit on all four sides • Control box is conveniently located with all controls factory wired • Corner patch plate allows access to compressor components • Drainage holes are provided in base section for moisture removal • High density polyethylene unit support feet raise the unit off of the mounting surface, away from damaging moisture PermaGuard'" Unit Base • Durable zinc -coated base section resists rust and corrosion is SmartHinge'" Louvered Coil Protection • Steel louvered panels provides complete coil protection • Panels are hinged to allow easy cleaning and servicing of coils • Panels may be completely removed • Interlocking tabs and slots assure tight fit on cabinet Refrigerant Line Connections, Electrical Inlets and Service Valves • Sweat connection suction and liquid lines • Located on corner of unit cabinet • Suction valve can be fully shut off, while liquid valve may be front seated to manage refrigerant charge while servicing system • Refrigerant line connections and field wiring inlets are located in one central area of the cabinet • See dimension drawing EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 6 SPECIFICATIONS General Model No. All Regions Data Southeast and North Regions Nominal Tonnage EL16XC1-018 EL16XC1-024 EL16XC1-030 EL16XC1-036 - - - - - - - - - EL16XC1 SO36 1.5 2 2.5 3 Connections Liquid line (o.d.) - in. (sweat) Suction line (o.d.) - in. 3/8 3/8 3/8 3/8 3/4 3/4 3/4 7/8 Refrigerant R-410A charge furnished 4 lbs. 9 oz. 4 lbs. 9 oz. 5 lbs. 8 oz. 7 lbs. 1 oz. Outdoor Net face area - sq. ft. Outer coil Coil Inner coil Tube diameter - in. No. of rows Fins per inch 13.22 16.33 21.00 16.33 - - - - - - - - - 15.75 5/16 5/16 5/16 5/16 1 1 1 2 26 26 26 22 Outdoor Diameter - in. Fan No. of blades Motor hp Cfm Rpm Watts 18 22 22 22 3 3 3 3 1/10 1/6 1/6 1/6 2290 3160 3160 3160 1075 825 825 825 160 215 215 190 Shipping Data - lbs. 1 pkg. 155 171 187 205 ELECTRICAL DATA Line voltage data - 60hz 208/23OV-1 ph 208/23OV-1 ph 208/23OV-1 ph 208/23OV-1 ph 2 Maximum overcurrent protection (amps) 20 25 25 30 3 Minimum circuit ampacity 11.9 14.6 17 18.0 Compressor Rated load amps Locked rotor amps Power factor 9.0 10.9 12.8 13.6 48 59.3 67.8 79 0.97 0.97 0.97 0.96 Outdoor Fan Motor Full load amps Locked rotor amps 0.7 1 1 1 1.3 1.9 1.9 1.9 CONTROLS iComfort® E30 Smart Wi-Fi Thermostat 20A65 Remote Outdoor Temperature Sensor X2658 OPTIONAL ACCESSORIES - ORDER SEPARATELY Compressor Crankcase Heater 93M04 Compressor Hard Start Kit Copeland LG 1OJ42 88M91 • Compressor Low Ambient Cut -Off Switch 45F08 Compressor Timed -Off Control 47J35 Freezestat 3/8 in. tubing 5/8 in. tubing 93G35 50A93 • Indoor Blower Off Delay Relay 58M81 Loss of Charge Switch Kit 84M23 • 4 Low Ambient Kit (Fan Cycling) 34M72 Refrigerant Line Sets L15-41-20 L15-41-30 L15-65-30 L15-41-40 L15-41-50 L15-65-40 L15-65-50 NOTE -Extremes of operating range are plus 10 % and minus 5 % of line voltage. Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and additional refrigerant charge required. HACR type breaker or fuse. Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Crankcase Heater and Freezestat are recommended with Low Ambient Kit. EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 7 SPECIFICATIONS General Model No. All Regions Data Nominal Tonnage EL16XC1-041 EL16XC1-042 EL16XC1-047 EL16XC1-048 EL16XC1-060 3.5 3.5 4 4 5 Connections Liquid line (o.d.) - in. (sweat) Suction line (o.d.) - in. 3/8 3/8 3/8 3/8 3/8 7/8 7/8 7/8 7/8 1-1/8 Refrigerant R-410A charge furnished 9 lbs. 9 oz. 8 lbs. 12 oz. 11 lbs. 0 oz. 9 lbs. 12 oz. 12 lbs. 0 oz. Outdoor Net face area - sq. ft. Outer coil Coil Inner coil Tube diameter - in. No. of rows Fins per inch 21.00 21.00 22.17 21.00 29.09 20.25 20.25 21.33 20.25 28.16 5/16 5/16 5/16 5/16 5/16 2 2 2 2 2 22 22 22 22 22 Outdoor Diameter - in. Fan No. of blades Motor hp Cfm Rpm Watts 22 22 26 22 26 3 3 4 4 3 1/6 1/6 1/3 '/4 1/3 3050 3050 4400 3600 4550 825 825 825 825 825 190 190 310 310 310 Shipping Data - lbs. 1 pkg. 227 234 272 255 284 ELECTRICAL DATA Line voltage data - 60hz 208/230V-1ph 208/230V-1ph 208/230V-1ph 208/230V-1ph 208/230V-1ph 2 Maximum overcurrent protection (amps) 30 40 35 40 50 3 Minimum circuit ampacity 19.3 23.4 21.9 24.2 29.6 Compressor Rated load amps Locked rotor amps Power factor 14.7 17.9 16.1 18.0 22.2 75 112 105.5 117 127.9 0.96 0.96 0.98 0.96 0.98 Outdoor Fan Motor Full load amps Locked rotor amps 1 1 1.8 1.7 1.8 1.9 1.9 2.9 3.2 2.9 CONTROLS - ORDER SEPARATELY iComfort° E30 Smart Wi-Fi Thermostat 20A65 Remote Outdoor Temperature Sensor X2658 OPTIONAL ACCESSORIES - ORDER SEPARATELY Compressor Crankcase Heater 93M04 93M06 Factory Compressor Hard Copeland 1OJ42 Start Kit LG 88M91 Compressor Low Ambient Cut -Off Switch 45F08 Compressor Timed -Off Control 47J35 Freezestat 3/8 in. tubing 93G35 5/8 in. tubing 50A93 Indoor Blower Off Delay Relay 58M81 Loss of Charge Switch Kit 84M23 4 Low Ambient Kit (Fan Cycling) 34M72 Refrigerant L15-65-30 L15-65-40 Line Sets L15-65-50 Field Fabricate NOTE -Extremes of operating range are plus 10% and minus 5% of line voltage. Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and additional refrigerant charge required. HACR type breaker or fuse. Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. ^ Crankcase Heater and Freezestat are recommended with Low Ambient Kit. EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 8 SOUND DATA ' Unit Model Octave Band Sound Power Levels dBA, re 10-11 Watts Center Frequency - HZ 1 Sound Rating Number (dBA) 2 Estimated Sound Pressure Level at Distance From Unit (dBA at distance in ft.) 125 250 500 1000 2000 4000 8000 3 5 10 15 50 018 55 61 67 68 63.5 59 50.5 72 65 60 54 51 40 024 55 62 67.5 66.5 63 59 52.5 72 65 60 54 51 40 030 54 61.5 66 66 62 57 51 71 64 59 53 50 39 036 56 66 69 67 62.5 57.5 50.5 73 66 61 55 52 41 041 54.5 62.5 67.5 67 62.5 58.5 52.5 72 65 60 54 51 40 042 55.5 62.5 68 67 62 57.5 51.5 72 65 60 54 51 40 047 55 62 67 66.5 62.5 57.5 49.5 72 65 60 54 51 40 048 55.5 64.5 70 71 65 60.5 54 75 68 63 57 54 43 060 55.5 62.5 1 67 1 66.5 62.5 60 1 53.5 73 66 61 55 52 41 NOTE - The octave sound power data does not include tonal correction. 1 Tested according to AHRI Standard 270-2008 test conditions. 2 Estimated sound pressure level at distance based on AHRI Standard 275-2010 method for equipment located on the ground, roof, or on side of building wall with no adjacent reflective surface within 9.8 feet. Sound pressure levels will increase based on changes to assumptions. For other applications, refer to AHRI Standard 275. FIELD WIRING DI SWITCHCT r r DI THERMOSTAT I SWITCHCT (By Others) (Required) (gy Others) --�---� t------� t----J LENNOX LENNOX AIR HEATING UNIT CONDITIONER OR AIR HANDLER UNIT INSTALLATION CLEARANCES N See NOTES OTES See NOTES ...,,,trol Box A -Two Wire Power (not furnished) B - Two Power (not furnished). See Electrical Data C - Four Wire Low Voltage (not furnished). 18 ga. minimum D - Five Wire Low Voltage (not furnished). 18 ga. minimum All wiring must conform to NEC or CEC and local electrical codes. NOTES: Service clearance of 30 in. (762 mm) must be maintained on one of the sides adjacent to the control box. Clearance to one of the other three sides must be 36 in. (914 mm) Clearance to one of the remaining two sides may be 12 in. (305 mm) and the final side may be 6 in. (152 mm). A clearance of 24 in. (610 mm) must be maintained between two units. 48 in. (1219 mm) clearance required on top of unit. EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 9 DIMENSIONS - UNIT r TOP VIEW C (depth) DISCHARGE AIRt 0 0 0 0 0 o 000000 ��� 4-3/4 4-1/4(108) (121) SUCTION LINE CONNECTION LIQUID LINE CONNECTION SIDE VIEW UNIT SUPPORT FEET \ 0 0 (216) (216) 0 8-3/4 (222) LIQUID LINE CONNECTION ELECTRICAL A INLETS SUCTION LINE CONNECTION 5-1/2 13-1 /2� (140) (343) EL16XC1-018 BASE SECTION (Small Base) 9-1/2 (241) 8-1/4 (210) Ur FE B (width) 1 (25) END VIEW EL16XC1-024 TO -060 BASE SECTION (Medium and Large Base) Model No. A in. mm B in. mm C in. I mm D in. imm E in. mm F in. imm G in. imm H in. mm J in. Imm K in. mm EL16XC1-018 31 787 27 686 28 711 --- --- --- --- --- --- --- --- --- --- --- --- --- --- EL16XC1-024 31 787 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524 EL16XC1-030 39 991 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524 EL16XC1-036 / EL16XClSO36 31 787 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524 EL16XC1-041 35 889 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524 EL16XC1-042 39 991 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524 EL16XC1-047 35 889 35-1/2 902 39-1/21003 16-7/8 429 8-3/4 222 3-1/8 79 30-3/4 781 4-5/8 117 3-3/4 95 26-7/8 683 EL16XC1-048 39 991 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524 EL16XC1-060 45 1143 35-1/2 902 39-1/21003 16-7/8 429 8-3/4 222 3-1/8 79 30-3/4 781 4-5/8 117 3-3/4 95 26-7/8 683 EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 10 TXV/ORIFICE USAGE Use this table for C35, CH23, CH35 and CR33 Field Installed TXV/Orifice Match -Ups Model No. Refrigerant Metering Orifice (RFC) Order No. Orifice Size Thermal Expansion Valve (TXV) EL16XC1-018 97M74 0.053 12J18 EL16XC1-024 97M75 0.057 12.118 EL16XC1-030 1OW99 0.065 12J18 EL16XC1-036 EL16XC1 SO36 11W02 0.073 12J19 EL16XC1-041 97M77 0.074 12J20 EL16XC1-042 97M78 0.076 112.120 EL16XC1-047 1OW86 0.080 12J20 EL16XC1-048 11W07 0.083 12J20 EL16XC1-060 10M13 0.097 112.120 CX35 and CHX35 coils and all Lennox air handlers are shipped with a factory installed TXV. In most cases, no change out of the valve is needed. If a change out is required it will be listed in the `TXV SUBSTITUTIONS" table by size. The correct TXV must be ordered separately and Feld installed. C35 and CH35 coils - Use the RFC orifice shipped with the outdoor unit or replace the factory installed RFC orifice with the expansion valve listed. CR33 and CH23 coils - Use the RFC orifice shipped with the outdoor unit or use the expansion valve listed. AHRI STANDARD 210/240 Cooling or heating capacities are net values, including the effects of blower motor heat, and do not include supplementary heat. Power input is the total power input to the compressor(s) and fan(s), plus any controls and other items required as part of the system for normal operation. Units which do not have an indoor air -circulating blower furnished as part of the model, i.e., split system with indoor coil only, is established by subtracting from the total cooling capacity 1250 Btu/h per 1,000 cfm, and by adding the same amount to the heating capacity. Total power input for both heating and cooling is increased by 365 W per 1,000 cfm of indoor air circulated. TXV SUBSTITUTION A general guide for replacing the factory installed TXV if the indoor unit (coil/air handler) is larger or smaller than the outdoor unit. Outdoor Unit Indoor Unit TXV Furnished TXV Replacement Size Tons Size Tons 018 1.5 30/36 2.5/3 112.119 12J18 018 1.5 36 3 12J19 12J18 018 1.5 42 3.5 12J20 12J18 018 1.5 48 4 12J20 12J18 018 1.5 49 4 12J20 12J18 018 1.5 50/60 4/5 12J20 112.118 018 1.5 51/61 4/5 12J20 112.118 018 1.5 60 5 12J20 12J18 024 2 42 3.5 12J20 12J18 024 2 48 4 12J20 12J18 024 2 49 4 12J20 12J18 024 2 50/60 5 12J20 12J18 024 2 51/61 5 12J20 12J18 024 2 60 5 12J20 12J18 030 2.5 42 3.5 12J20 12J18 030 2.5 43 3.5 12J20 12J18 030 2.5 48 4 12J20 12J18 030 2.5 49 4 12J20 12J18 036 3 24 2 12J18 12J19 036 3 30 2.5 12J18 12J19 042 3.5 24 2 12J18 112.120 042 3.5 30 2.5 12J18 12J20 042 3.5 30/36 3 12J19 12J20 042 3.5 36 3 12J19 12J20 048 4 30/36 2.5/3 12J19 12J20 048 4 36 3 12J19 12J20 TXV Ranges: 12J18 - 1.5 to 2.5 ton systems - Use on 2.5 ton (030) and lower systems. 12J19 - 3 ton systems - Use down to 2 ton (024) systems. 12J20 - 3.5 to 5 ton systems - Use down to 3 ton (036) systems. EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 11 REVISIONS Sections Optional Accessories TXV Substitutions LEN;NP E .) Updated. Updated. Description of Change A © ,/MfMBfR COMPANY CM c us 0STE'D ntertek Visit us at www.Lennox.com For the latest technical information, www.LennoxPros.com Contact us at 1-800-4-LENNOX NOTE - Due to Lennox' ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. ©2020 Lennox Industries, Inc.