Harb Fire Damage Repair Structural Drawings 03.02.20STRUCTURAL NOTES O 14M (THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS) CODE ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION. SPECIFICATIONS AND STANDARDS WHERE REFERENCED ON THE DRAWINGS ARE TO BE THE LATEST EDITION. DESIGN LOADS DEAD LOADS: ROOF 15 PSF FLOOR 15 PSF LIVE LOADS: ROOF (SNOW LOAD) 25 PSF FLOOR 40 PSF (LIVE LOADS ARE REDUCED WHERE PERMISSIBLE PER IBC SECTION 1607.10). STATEMENT OF SPECIAL INSPECTIONS SPECIAL INSPECTIONS ARE REQUIRED AS INDICATED IN THE FOLLOWING TABLE. THE CONTRACTOR SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND OWNER PRIOR TO COMMENCEMENT OF WORK IN ACCORDANCE WITH CHAPTER 1704.4 OF THE IBC. FREQUENCY AND DISTRIBUTION OF REPORTS - INSPECTION REPORTS SHALL BE PROVIDED FOR EACH DAY ON SITE BY SPECIAL INSPECTOR. STRUCTURAL OBSERVATION REPORTS SHALL BE PROVIDED AFTER EACH OBSERVATION. REPORTS SHALL BE DISTRIBUTED TO THE CONTRACTOR, ARCHITECT, ENGINEER AND BUILDING OFFICIAL. SPECIAL INSPECTION NOT REQUIRED FOUNDATIONS: SPREAD FOOTINGS SOILS REPORT: REPORT NO: PREPARED BY: DATED: ALLOWABLE SOIL PRESSURE: 2000 PSF (ASSUMED; TO BE FIELD VERIFIED DURING CONSTRUCTION) LATERAL EARTH PRESSURE: UNRESTRAINED: RESTRAINED: PASSIVE: COEFFICIENT OF FRICTION 35 PCF + ANY APPLICABLE SURCHARGE 50 PCF + ANY APPLICABLE SURCHARGE 300 PCF 0.35 FOOTINGS SHALL BEAR ON FIRM UNDISTURBED EARTH OR 12" OF COMPACTED STRUCTURAL FILL AS REQUIRED AND AT LEAST 18" BELOW ADJACENT EXTERIOR GRADE. ANY FOOTING ELEVATIONS SHOWN IN THE DRAWINGS REPRESENT MINIMUM DEPTHS AND ARE FOR BIDDING ONLY. ACTUAL FOOTING ELEVATIONS ARE SUBJECT TO SITE CONDITIONS AND MUST THEREFORE BE ESTABLISHED BY THE CONTRACTOR. FOOTINGS SHALL BE CENTERED BELOW COLUMNS OR WALLS ABOVE, UNLESS NOTED OTHERWISE. IMPORTED STRUCTURAL FILL AND BACKFILL MATERIAL SHOULD CONSIST OF CLEAN, WELL GRADED GRANULAR MATERIAL FREE OF DEBRIS OR ORGANICS WITH A MAXIMUM PARTICLE DIAMETER OF THREE INCHES AND NO MORE THAN 10% FINES (PASSING THE #200 SIEVE). FILL AND BACKFILL MATERIAL SHOULD BE PLACED IN LEVEL LIFTS NOT EXCEEDING TWELVE (12") INCHES IN LOOSE THICKNESS AND COMPACTED TO A MINIMUM OF 95% OF ITS MAXIMUM DRY DENSITY AS DETERMINED BY ASTM TEST METHOD D1557-00. BACKFILL BEHIND ALL RETAINING WALLS WITH WELL -DRAINING, GRANULAR FILL AND PROVIDE FOR SUBSURFACE DRAINAGE. PROVIDE DAMPPROOFING AT EXTERIOR FACE OF ALL FOUNDATION WALLS EXPOSED TO EARTH PER ARCHITECTURAL SPECIFICATIONS. EXCAVATIONS AND DRAINAGE INSTALLATION SHALL BE OBSERVED BY A SOILS ENGINEER RETAINED BY THE OWNER. IF EXCAVATION SHOWS SOIL CONDITIONS TO BE OTHER THAN THOSE ASSUMED ABOVE NOTIFY THE STRUCTURAL ENGINEER FOR POSSIBLE FOUNDATION REDESIGN. EXPANSION ANCHORS BASE MATERIAL ANCHOR SIZE MINIMUM ALLOWABLE ALLOWABLE SHEAR EMBEDMENT TENSION CONCRETE 1/2"0 3 1/2" 1,929 2,009 CONCRETE 5/8"0 4" 2,637 3,447 CONCRETE 3/4"0 1 4 3/4" 1 3,481 1 5,140 NOTE: 1. THE ABOVE VALUES ARE BASED ON HILTI CARBON STEEL KWIK BOLT III EXPANSION ANCHORS INSTALLED IN NORMAL WEIGHT CONCRETE, f'c = 2500 PSI. 2. SPECIAL INSPECTION IS REQUIRED PRIOR TO INSTALLING ANCHOR PER THE MANUFACTURER'S ICBO REPORT. 3. THE ABOVE VALUES ARE BASED ON AN EDGE DISTANCE GREATER THAN 10" AND A MINIMUM SPACING OF 12". CONTACT ENGINEER FOR OTHER CONDITIONS. LUMBER ALL GRADES SPECIFIED ARE MINIMUM GRADES REQUIRED. ALL LUMBER SHALL BE IN ACCORDANCE WITH WWPA GRADING RULES, KILN -DRIED TO MC 19 AND OF THE FOLLOWING MINIMUM STANDARDS: SIZE CLASSIFICATION SPECIES GRADE Fb (PSI) Fc (PSI) SLEEPERS DOUG-FIR STUD 700 - LIGHT FRAMING (STUDS) HEM -FIR STUD 675 800 2x JOISTS AND PLANKS HEM -FIR #2 850 - PLATES AND BLOCKING HEM -FIR #2 850 - 6x AND LARGER BEAMS AND STRINGERS DOUG-FIR #2 875 - 4x AND SMALLER BEAMS AND STRINGERS HEM -FIR #2 850 - ALL POSTS AND TIMBERS DOUG-FIR #1 1200 1000 REFER TO PLAN NOTES, SCHEDULES, AND DETAILS FOR MORE SPECIFIC LUMBER SIZE AND GRADE REQUIREMENTS. UNLESS NOTED OTHERWISE IN THE PLANS, ALL WOOD AND WOOD -BASED MEMBERS EXPOSED TO WEATHER OR IN CONTACT WITH CONCRETE, MASONRY, OR WITHIN 8" OF SOIL SHALL BE PRESERVATIVE -TREATED BY VACUUM -PRESSURE IMPREGNATION IN ACCORDANCE WITH AWPA STANDARD U1. NAILS, BOLTS, AND METAL CONNECTORS FOR WOOD ALL NAILS SHALL CONFORM TO THE STANDARDS SET FORTH BY THE NATIONAL DESIGN STANDARDS (NDS) FOR WOOD CONSTRUCTION, LATEST EDITION. NAILING NOT SPECIFIED SHALL BE PER IBC TABLE 2304.10.1 NAILING SCHEDULE. ALL NAILS CALLED OUT ON PLANS SHALL BE COMMON NAILS UNLESS NOTED OTHERWISE AND SHALL MEET OR EXCEED THE FOLLOWING MINIMUM GUIDELINES: NAIL SHANK 0 MIN LENGTH 8d COMMON 0.1310 2 1/2" SHANK 10d COMMON 0.1480 3" SHANK 12d COMMON 0.1480 3 1/4" SHANK 16d COMMON 0.1620 3 1/2" SHANK 10d BOX NAILS MAY BE SUBSTITUTED FOR 8d COMMON NAILS WITH NO CHANGE IN NAIL SPACING. FRAMING MEMBERS MAY BE NAILED WITH 16d SINKERS (0.148" 0 x 3 1/4"), BUT ONLY 16d COMMON NAILS SHALL BE USED WHERE 16d NAILS ARE INDICATED IN THIS DRAWING SET. ENGINEER MAY APPROVE OTHER NAILS IF NAIL LABELS ARE SUBMITTED TO ENGINEER PRIOR TO START OF CONSTRUCTION. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. LEAD HOLES FOR LAG BOLTS SHALL BE BORED FOR THE SHANK AND THREADED PORTIONS PER NDS 11.1.3. CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, CATALOG TO BE THE LATEST EDITION, OR ENGINEER APPROVED EQUAL. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND WITH THE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY THE MANUFACTURER. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS, SCREWS, OR BOLTS IN EACH MEMBER. INSTALL SOLID BLOCKING AT ALL BEARING POINTS. ALL SHIMS SHALL BE SEASONED, DRIED, AND THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. GALVANIZATION UNLESS NOTED OTHERWISE, STEEL CONNECTORS IN CONTACT WITH TREATED WOOD SHALL BE GALVANIZED ACCORDING TO THE FOLLOWING TABLE: GALVANIZATION UNTREATED WOOD CCA-C SBX ACQ-C ACQ-D CBA-A CA-B OTHER BORATE ACZA OTHER PT WOOD G90 X X X G 185 X X X X X X HDG X X X X X X STT300 X X X X X X X X G90 = 0.90 OZ. OF ZINC PER SQUARE FOOT OF AREA G185 = 1.85 OZ. OF ZINC PER SQUARE FOOT OF AREA HDG = HOT DIP GALVANIZED SST300 = TYPE 316L STAINLESS STEEL RATED SHEATHING RATED SHEATHING SHALL BE GRADE C-D INT-APA WITH EXTERIOR GLUE OR OSB SHEATHING WITH EXTERIOR GLUE IN CONFORMANCE WITH IBC STANDARD 2303.1.4. TIMBERSTRAND, MICROLLAM, AND PARALLAM MEMBERS FABRICATED IN CONFORMANCE WITH THE INTERNATIONAL CODE COUNCIL EVALUATION SERVICE (ICC-ES) REPORT NO. ESR-1387 OR CCMC REPORT NO. 12627-R, 08675-R, AND 11161-R. EACH MEMBER SHALL BE IDENTIFIED BY A STAMP INDICATING THE PRODUCT TYPE AND GRADE, ICC-ES OR CCMC REPORT NUMBER, MANUFACTURER'S NAME, PLANT NUMBER AND INDEPENDENT INSPECTION AGENCY'S LOGO. FABRICATOR SHALL BE CERTIFIED. MEMBERS SHALL MEET THE FOLLOWING MINIMUM STANDARDS: SIZE CLASSIFICATION SPECIES GRADE Fb (PSI) Fv (PSI Fc (PSI) BEAMS & POSTS (d < 9 1/2") LSL 1.3E 1,700 425 1,835 RIMS & BEAMS (d >_ 9 1/2") LSL 1.55E 2,325 310 - BEAMS & POSTS LVL 2.0E 2,600 285 2,510 POSTS (d < 9 1/2") PSL 1.8E 2,400 190 2,500 BEAMS (d >_ 9 1/2") PSL 2.0E 2,900 290 - TIMBERSTRAND, MICROLLAM, AND UNTREATED PARALLAM MEMBERS ARE INTENDED FOR DRY -USE APPLICATIONS. UNLESS NOTED OTHERWISE, ENGINEERED WOOD BEAMS EXPOSED TO WEATHER SHALL BE TREATED PER MANUFACTURES RECOMMENDATIONS. TYPICAL FRAMING NOTES 1. BEARING WALL FRAMING 2x STUDS @ 16" OC FOR ALL SHEAR AND/OR BEARING WALLS UNO. REFER TO FRAMING PLAN NOTES FOR TYPICAL DOOR & WINDOW HEADERS NOT CALLED OUT ON THE PLANS. HEADERS SHALL BE SUPPORTED BY A MINIMUM OF (1) CRIPPLE AND (1) FULL HEIGHT STUD UNO. COLUMNS BELOW FLUSH MULTIPLE JOIST BEAMS SHALL BE EQUAL IN WIDTH TO THE BEAM. ALL COLUMNS NOT CALLED OUT OTHERWISE SHALL BE TWO STUDS. WALL PLATES BEARING ON CONCRETE SHALL BE PRESSURE -TREATED. FOR ALL EXTERIOR AND INTERIOR WALLS, BOLT PLATES OR SILLS TO CONCRETE WITH 5/8 INCH DIAMETER ANCHOR BOLTS WITH 7 INCH MINIMUM EMBEDMENT. PLACE AT 5'-0" OC MAXIMUM FOR SHEAR WALLS, AND AT 6-0" OC FOR BEARING WALLS AND OTHER PARTITIONS. USE MINIMUM OF TWO ANCHOR BOLTS PER SILL AND PLACE ONE WITHIN 12 INCHES OF EITHER END TYPICAL UNLESS NOTED OR DETAILED OTHERWISE. REFER TO SHEAR WALL SCHEDULE. AT ALL SILL PLATE ANCHOR BOLTS, CONTRACTOR SHALL INSTALL 1/4" x 3" x 3" FLAT PLATE WASHERS. 3. ROOF AND FLOOR FRAMING PROVIDE 1 1/2" FULL DEPTH BLOCKING FOR JOISTS AND RAFTERS AT ALL SUPPORTS AND AT 8'-0" OC MAXIMUM UNO. INTERMEDIATE 8'-0" OC BLOCKING NOT REQ'D IF GWB CEILING IS INSTALLED DIRECTLY TO UNDERSIDE OF FRAMING. INSTALL DOUBLE JOISTS UNDER PARTITIONS EXTENDING ONE HALF OR MORE OF THE JOIST SPAN. PROVIDE TRUSS BLOCKING PANELS FOR ROOF TRUSSES AT SUPPORTS AND SHEAR WALLS, AND WHERE INDICATED ON PLANS AND DETAILS. 4. DIAPHRAGM NAILING ALL SHEAR WALLS, FLOOR AND ROOF DIAPHRAGM NAILINGS SHALL BE AS CALLED OUT ON SCHEDULES OR ON THE PLANS. EXTERIOR WALLS NOT INDICATED AS SHEAR WALLS SHALL BE SHEATHED AND NAILED TO SUPPORTING FRAMING WITH 8d NAILS AT 6" OC AT ALL PANEL EDGES AND 12" OC AT ALL INTERMEDIATE SUPPORTS. THE USE OF NAIL GUNS WILL BE APPROVED IF NAILING INTO THE DIAPHRAGMS CAN BE INSTALLED FLUSH WITH FACE OF SHEATHING. NAIL PENETRATIONS GREATER THAN 1/16" ARE NOT ACCEPTABLE. 5. ALLOWABLE STUD AND PLATE PENETRATIONS CUTTING AND/OR NOTCHING OF WOOD STUDS OR PLATES SHALL NOT EXCEED 25% OF THE STUD/PLATE WIDTH IN EXTERIOR AND BEARING WALLS AND SHALL NOT EXCEED 40% OF THE STUD/PLATE WIDTH IN ANY NON -BEARING PARTITIONS. BORED HOLE DIAMETER IS LIMITED TO 40% OF STUD/PLATE WIDTH IN ANY STUD AND MAY BE 60% IN NONBEARING PARTITIONS OR IF STUD IS DOUBLED. MAINTAIN 5/8" MINIMUM EDGE DISTANCE FROM HOLE EDGE. 6. GYPSUM WALLBOARD NAILING ALL GYPSUM WALLBOARD SHALL BE NAILED TO ALL STUDS AND TOP AND BOTTOM PLATES WITH 6d COOLER NAILS OR NO. 13 GAUGE x 1 5/8" @ 7" OC (5d COOLER NAILS FOR 1/2 INCH GYPSUM SHEATHING). TYPICAL UNLESS NOTED OTHERWISE. INSTALLATION OF GWB SHALL BE SUCH THAT JOINTS ARE STAGGERED ON EACH SIDE OF A SINGLE WALL. EXISTING BUILDING CONTRACTOR SHALL VERIFY ALL DIMENSIONS, MEMBER SIZES AND CONDITIONS OF THE EXISTING BUILDING DEPICTED IN THE DRAWINGS, AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES FOR POSSIBLE REDESIGN. CONTRACTOR RESPONSIBLE FOR COMPLETELY SEALING ALL AREAS WHERE EXISTING ROOF MATERIAL IS PENETRATED OR REMOVED. PROVIDE WATER PROOFING AS REQUIRED BY THE ARCH. GENERAL STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL, CIVIL, ELECTRICAL, AND MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS FOR COMPATIBILITY BEFORE PROCEEDING. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. CONTRACTOR TO SEE ARCHITECTURAL, CIVIL, ELECTRICAL AND MECHANICAL DRAWINGS FOR SIZE AND LOCATION OF PIPE, VENT, DUCT AND OTHER OPENINGS AND DETAILS NOT SHOWN ON THESE DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION STABILITY AND TEMPORARY SHORING AS NECESSARY UNTIL PERMANENT SUPPORT AND STIFFENING ARE INSTALLED. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE City Of Edmonds Building Department Work Address Owner Approved Date zfP-a-11r Building Official 04132020 Permit Number LEGEND DEFINITION DIRECTION OF FRAMING SYMBOL DEFINITION NATIVE SOIL SYMBOL I I mI m I m I m I I EXTENT OF FRAMING GRANULAR FILL STRUCTURAL STEEL COLUMNS COLUMN BEARING ON BEAM P RATED SHEATHING BEAM CONTINUOUS OVER SUPPORT 0 SHEAR WALL (SEE SCHEDULE) SWX CONCRETE WALL COLUMN MARK (SEE SCHEDULE) BEARING STUD WALL FOOTING MARK (SEE SCHEDULE) O NON -BEARING STUD WALL l' J HOLDOWN MARK (SEE SCHEDULE) BEARING STUD SHEAR WALL NON -BEARING STUD SHEAR WALL CMU WALL HANGER MARK (SEE SCHEDULE) FLAG NOTE (SEE PLAN NOTES) STEEL MOMENT FRAME CONN. O ABBREVIATIONS (A) ABOVE ANCHOR BOLT GLB GLUE -LAMINATED BEAM AB HORIZ HORIZONTAL ALT ALTERNATE ARCHITECT KP KING POST KIPS PER SQUARE INCH ARCH KSI (B) BELOW L ANGLE BD BAR DIAMETER MECH MECHANICAL BLKG BLOCKING MF MOMENT FRAME BM BEAM BOTTOM MTL METAL NEAR SIDE BOT NS BRNG BEARING OC ON CENTER OPPOSITE BTWN BETWEEN OPP CJP COMPLETE JOINT PENETRATION PL PLATE PLACES CLR CLEAR PLCS CMU CONCRETE MASONRY UNIT PSI POUNDS PER SQUARE INCH COL COLUMN PSF POUNDS PER SQUARE FOOT CONC CONCRETE P/T POST TENSIONED CONN CONT CONNECTION CONTINUOUS PT REINF PRESSURE TREATED REINFORCING COORD COORDINATE DOUBLE REQ'D REQUIRED SCHEDULE DBL SCHED DIET DETAIL SIM SIMILAR SLAB ON GRADE DIA DIAMETER SOG DIM DIMENSION STD STANDARD STIFFENER DIR DIRECTION STIFF EA EACH STL STEEL ELEV ELEVATION SYMM SYMMETRICAL ES EACH SIDE SW SHEARWALL EX EXISTING TOC TOP OF CONCRETE EXP EXPANSION TOS TOP OF STEEL FLR FLOOR TOW TOP OF WALL FDN FOUNDATION FOOTING TYP TYPICAL FTG UNO UNLESS NOTED OTHERWISE FS GC FAR SIDE VERT VERTICAL GENERAL CONTRACTOR WF WIDE FLANGE ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 W 02/ 2020 O LJ Q O C) ---, M O DESIGN: ATN DRAWN: JEG CHECK: DMT JOB NO: 20052.10 DATE: 03/02/2020 a 0- Li 01:� W 3:: O 00 a J rn a�Q 0 _ 3:: W O .� 00 V) L.L 0 M Z � M < rn 0 Ld SHEET: Simi w i J 14= - 4m ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 F-------------------------------- I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I ZS M • ?+ SLAB ON 'JF WAs� GRADE I I ti� I I 45901 1 I I ORAL I I 0NAL I I W 0212020 I I I I I I I I I I I I----- J IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII -------------------------------- — IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII QQQ� (D NON< EXIST BEAM ZO om I_ ~2 w Lu Q SLAB ON GRADE �p Q� m UZ O N U Q F-1 I EXIST BEAM DESIGN: ATN \ DRAWN: JEG CHECK: DMT JOB NO: 20052.10 DATE: 03/02/2020 L-------------------J I ---- r, 1 SJ FOUNDATION PLAN wIw2..L � Z SCALE: 1/4"=10" NQ 2'-0" 0 2'-0" 4'-w O O <00 aa Oow 0 No0 zZ m o O O<rno �ZQ Lii i w LL- SHEET: S201 UZ H_Y NU Xw w0 IIIIII IIiIIIIIIIII IIIII OXw ROOF FRAMING PLAN SCALE: 1/4" = V-0" 2'-0" I I I I I I I ROOF OVERHANG I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I EF=:�o 2'-0" 4'-0" 4= - 4m ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 W 0212020 O LJ [-- N Q O n ---, rn O 1 DESIGN: ATN DRAWN: JEG CHECK: DMT J O B NO: 20052.10 DATE: 03/02/2020 � Z a Q W Q-.: co W O (^ a 0 Z J arn CLQ p = Q W �- �00N L� p M Z L.. � � O lO 0) p O W 2 Ld � z J SHEET: S2m2 O 14ml STAGGER NAILS ON EA SIDE OF PANEL JOINT AS REQUIRED PER SHEAR WALL SCHED —n-------r— — I•j II I•I II HEADER PER PLAN II II I I II II I I I•I •11 II I I I I I•I II I I I I I CRIPPLE STUDS PER I I•I I I j I I 11 PLAN; DO NOT CUT 1 II 1 1.1 I•I I• AWAY MATERIAL FROM 1 I• I I I I I I I• I CRIPPLE STUDS j 1 I I 1 II 1 1 I I II I •I 1,1 I 1 I 1.1 I I 1 1 1 I I I I I I I I •1 1 1 1 1 1 1 I•I I I I• I I.I FULL -HEIGHT 1 I•I 1 I I I I 1 1 1 1 HOLDOWN CHORD 1 1 1 1 1 1 1111 II I I I •1 1 1 1 11 11.11 11 II I I I I' I 11 1111 II II I.I II 1 1 1 1 I•I 11.11 I I I I I I I, I 1 1 I.I 11 1111 II 11.11 I I 1111 II II I I II I 1 I' I I.I 11 11 II 1 1 1 1 I•I 1 1.1 1 I I 1 1.1 I I I I 1 1 I• I I• 1.1 11 AB W/ SIMPSON BP 1 II 1 1 II I I I,I I Ij 1 PL WASHER, TYP I I I•I II I I I •1 I 1 I•� • 1 1•I � PT SILL PL PER SHEAR I I I 1 1 1 1 WALL SCHED I I I A I•I I 1.1 II _ z II II CONCRETE FOOTING OR P/T SLAB NOTES: 1. REFER TO STRUCTURAL NOTES FOR ADDITIONAL INFORMATION. 2. FOR SHEAR WALLS WHERE NO HOLDOWNS ARE SPECIFIED THE FIRST AB SHALL BE LOCATED NOT MORE THAN V-0" AND NOT LESS THAN (7) BOLT DIAMETERS FROM END OF WALL. TYPICAL SHEAR WALL DETAIL SCALE: 3/4" = V-0" - - - - - - - - - - - - - - - - - - - - --------rn I'I I'I I'I I•I 11•I II II II II III II II II II III I I I I I I I I I II II II II III II II II II III I'I I'I I'I I•I 11. II I II II II II FRAMING AT ADJOINING I I I'I 1 1 PANEL EDGES PER SHEAR I I I I'I WALL SCHED 1 I II 1I 1 111 I I 11 I I 11 11•I II 11 11 11 111 II II II II II II II II II ,J L ;-- ;---j,I.-- ;-- ;--i- --1 r------ I I I I 101 11 II II 11 II II II II II II II II II II II 101 II II II II II II II II II II II II II II II 101 11 II II II II II II II II II II II II II II 101 II II II _1L---___��______� ------ II II I II II 11 II II II II II 11 1L—_ _1L------1 AB SIZE AND SPACING __;A III— II I I PER PLAN AND SHEAR 1� WALL SCHEDULE, TYP RIM BOARD �\ OR BLOCKING -III=III- -III=III- -III=III- EDGE NAILING PER PLAN AND SHEAR WALL SCHEDULE OR STRUCTURAL NOTES, TYP 0.131"0 x 3" NAILS @ 9" OC (2) ROWS OF 0.131" 0 x 3" NAILS @ 9" OC STUD WALL PER FRAMING PLAN NOTES, TYP EDGE NAILING PER PLAN AND SHEAR WALL SCHEDULE OR STRUCTURAL NOTES, TYP SHEATHING (OR GWB) AND NAILING PER PLAN AND SHEAR WALL SCHEDULE OR STRUCTURAL NOTES, TYP A. CORNER INTERSECTION B. 'T' INTERSECTION TYPICAL WALL INTERSECTION DETAIL SCALE: 1" = V-0" PANEL EDGE NAILING PER SHEAR WALL SCHEDULE, TYP PANEL EDGE NAILING INTO HOLDOWN CHORDS, TYP INTERMEDIATE NAILING @ 12" OC SHEATHING PER PLAN AND SHEAR WALL SCHEDULE HOLDOWN CHORD PER SCHEDULE. REFER TO TYPICAL BUILT-UP COLUMN DETAIL ADDITIONAL END STUD IF REQUIRED TO PROVIDE COUNTERSINK FOR HOLDOWN BOLTS HOLDOWN ANCHORAGE PER PLAN AND SCHEDULE SIMPSON CNW COUPLER 1/2" TO NUT W/ SIZE TO MATCH SHEATHED EDGE HOLDOWN ANCHORAGE PANELEDGE NAILING PER SHEAR WALL SCHED CONTINUE HOLDOWN CHORD TO FOUNDATION 2x6 STUD @ 2x4 CROSS WALL 2x8 STUD @ 2x6 CROSS WALL EDGE NAILING PER PLAN AND SHEAR WALL SCHEDULE OR STRUCTURAL NOTES, TYP 0.131"0 x 3" NAILS @ 9" OC STUD WALL PER FRAMING PLAN NOTES, TYP SHEATHING (OR GWB) AND NAILING PER PLAN AND SHEAR WALL SCHEDULE OR STRUCTURAL NOTES, TYP CONCRETE STEM WALL CONCRETE FOOTING PLATE WASHER PER SHEAR WALL SCHED SECTION A -A SCALE: 1 1/2" = V-0" EDGE NAILING PER PLAN AND SHEAR WALL SCHEDULE OR STRUCTURAL NOTES, TYP (2) ROWS OF 0.131" 0 x 3" NAILS @ 9" OC EDGE NAILING PER PLAN AND SHEAR WALL SCHEDULE OR STRUCTURAL NOTES, TYP (2) ROWS OF 0.131"O x 3" NAILS @ 9" OC (EACH SIDE OF PARTY WALL) STUD WALL PER FRAMING PLAN NOTES, TYP SHEATHING (OR GWB) AND NAILING PER PLAN AND SHEAR WALL SCHEDULE OR STRUCTURAL NOTES, TYP C. PARTY WALL INTERSECTION NOTE: STAGGER SHEATHING AS SHOWN. (IBC TABLE 2306.3.1, CASE 1 SHEATHING PANEL, TYP CONTINUOUS PANEL EDGES SUPPORTED PANEL EDGES 2x OR 3x BLOCKING ONLY IF BLOCKED DIAPHRAGM (SHEAR WALL, BEAM, OR DRAG STRUT) TYPICAL FLOOR/ ROOF SHEATHING DETAIL SCALE: NTS SIMPSON A35 (ONLY REQUIRED AT EXTERIOR HEADERS GREATER THAN 6' SPAN) (6) 0.131"0 x 3" NAILS NAILING PER TYP BUILT-UP STUD COLUMN DETAIL AT HOLDOWNS: PROVIDE FULL HT HOLDOWN CHORDS PER HD SCHED OTHERWISE: (1) 2x FULL HT TYP DOUBLE TOP PLATE BEAM OR HEADER PER PLAN AND NOTES CRIPPLE STUDS PER PLAN AND COLUMN SCHEDULE OR STRUCTURAL NOTES TYPICAL HEADER DETAIL SCALE: 1" = V-0" SAWCUT EXIST CHARRED TRUSS TAIL @ EXTERIOR WALL SIMPSON RBC CLIP EACH TRUSS SPACE DIAPHRAGM BOUNDARY NAILING W/ 8d COMMON NAILS @ 6" OC 2x BIRD BLOCKING OFFSET 3/4" MAX FROM EDGE OF DOUBLE TOP PLATE 4'-0" MIN\X 1/2" PL 40/20 REPLACEMENT SHEATHING WHERE REQ'D W/ 8d COMMON NAILS @ 6" AT ALL DIAPHRAGM BOUNDARIES, PANEL EDGES, AND BLKG. NAILING AT INTERMEDIATE FRAMING SHALL BE 8d COMMON NAILS @ 12" OC. 3" 3„ 3„ • ° MIN ° • • ° (2) 10d EA END, • • TYP — EXIST TRUSS PER SISTER NEW 2x4 HF#2 PROVIDE BOUNDARY PLAN MEMBER TO EXIST NAILING AT TOP PLATE TRUSS W/ 10d @ 3" OC W/ 8d COMMON NAILS SIMPSON H2.5A STAGGERED 2" ABOUT @ 6" OC TIE AT EACH TRUSS CENTERLINE; (8) TOP & EXIST STUD WALL BOT MIN REPLACEMENT T1-11 SHEATHING W/ 8d COMMON FRAMING NAILS @ 6" OC AT ALL DIAPHRAGM BOUNDARIES, PANEL EDGE, AND BLKG. NAILING AT INTERMEDIATE FRAMING SHALL BE 8d COMMON NAILS @ 12" OC TYPICAL TRUSS SUPPORT DETAIL W/ RBC CLIP SCALE: 1" = V-0" ADJACENT NAILS IN A ROW ARE TO BE DRIVEN FROM OPPOSITE SIDES, TYP FOR 2x4 STUDS, PROVIDE SINGLE ROW OF NAILS STAGGERED EA SIDE WITH 1 1/2" EDGE DISTANCE. FOR 2x6 STUDS, PROVIDE (2) ROWS OF NAILS SPACED AT 2 1/2" W/ 1 1/2" EDGE DISTANCE 9" OC MAX SPACING BETWEEN ADJACENT NAILS IN A ROW 0.131"0 x 3" NAILS, TYP (5) STUDS MAX TO BE USED FOR BUILT-UP COLUMNS TYPICAL BUILT-UP STUD COLUMN DETAIL SCALE: 1" = V-0" 2 1/4" END DISTANCE, TYP (2) ROWS OF (8) 0.131"0 x 3" NAILS @ 3" OC EA SIDE OF SPLICE AND (2) @ 9" OC ELSEWHERE W/ 1 1/2" EDGE DISTANCE 3" OC \ SPACING i \ TOP CHORD SPLICE J AT LOCATIONS WHERE IT IS NOT POSSIBLE BOTTOM TO INSTALL THE SPECIFIED 0.131"0 CHORD SPLICE NAILS, THE CONTRACTOR SHALL SPLICE INSTALL SIMPSON CS20 STRAPS EA SIDE OF WALL AT SPLICE. INSTALL EA STRAP W/ (12) 10d AT EA END. WHERE BOTH PLATES ARE CUT, INSTALL CS20 STRAPS AT EA PLATE AND EA SIDE OF THE WALL. 6'-0" MIN BETWEEN SPLICES I SPLICES TO OCCUR AT CENTER OF VERTICAL STUDS TOP CHORD SPLICE BOTTOM CHORD SPLICE TYPICAL TOP PLATE SPLICE DETAIL SCALE: 1" = V-0" ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 W 02/ 2020 J H H z O_ m F- �_ N D H O (n � W Lu Q a O W Q � c» O Y D' Q DESIGN: ATN DRAWN: JEG CHECK: DMT JOB NO: 20052.10 DATE: 03/02/2020 a CL W 3:: 0 00 a J rn a�Q 0 W 0 00 V) E: 0 M Z m o 0 Q 0) M _ W SHEET: 0 O S3ml