Loading...
REVIEWED BLD BLD2020-1092+Interior_Lighting_Summary+10.15.2020_2.40.51_PM2015 Washington State Enerqv Code Compliance Forms for Commercial Build inqs including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Info Project Title: Sound Credit Union - Edmonds Date 1/1/2017 Compliance Applicant Information. Provide contact information for individual mho can For Building Department Use forms do not respond to inquiries about compliance form information provided. require a Company Name: JPC Architects, LLC BLD2020-1092 password to use. Company Address: 909 112th Ave NE Suite 206 RECEIVED Instructional and calculating cells Applicant Name: Teresa Portman are mrite-Oct19 2020 protected. Applicant Phone: 425-460-2370 CITY OF EDMONDS carchitects.com DEVELOPMENT SERVICES Applicant Email: teresap@jpcarchitects.com DEPARTMENT Project Description 0 New Building 0 Addition 0 Alteration 0 No Lighting Scope Include PROJ-SUM form (included in envelope forms vtorkbook) vuth lighting compliance forms. Interior Lighting System New and Existing light fixture Description REVIEWED BY 0 Interior Lighting Plans Included CITY OF EDMONDS Interior Lighting Power p Building Area Method 0 Space -by -space Method Allowance Method Select method used in project. Interior Lighting Controls 0 All C405.2.1- C405.2.8 Lighting Controls 0 C405.2 Exception 5 Luminaire Level Lighting Controls (LLLC) o Additional Efficiency Package Option C406.4 Enhanced Digital Lighting To comply vdth C406.4, no less than 90% of the total installed interior lighting poorer shall comply vdth required controls per C406.4. Dwelling Unit Interior Permanently installed interior lighting fixtures in dvielling units comply viith: No Dwelling Lighting Units 4 C405.2 thru C405.5 Commercial Lighting Controls and LPA 4 C406.3 High Efficacy Lighting R404.1 Residential High Efficacy Lighting. Dmelling unit lighting complies vdth WSECResidential provisions in lieu of WSEC Commercial provisions. Exterior Lighting System Existing light fixtures, 2x4 recessed, 2x2 recessed, linear pendants, recessed can lights to Description be relamped with LED lamps. 0 Exterior Lighting Plans Included Building Additions Compliance Method Interior lighting Exterior lighting Lighting systems in addition area comply with all applicable provisions as a stand alone new construction project Refer to Section C502.2.6 for additional Lighting systems in addition are combined with existing requirements. building lighting systems to demonstrate compliance Addition is combined with existing: For interior lighting projects, include new + existing -to -remain interior lighting fixture mettage in Proposed Lighting Wattage table in LTG-INT-BLD or L TG-INT-SPA CE form. For exterior lighting projects, include new + existing -to -remain exterior lighting fixture wattage in Proposed Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG-EXT form. 2015 Washington State FnPmv Cnde Cmmnliance Fnrms for Commercial 13uildinas including R2 R3_ R4 nver 3 stnries and all R1 Revised Nnv 2017 Project Title: Sound Credit Union -Edmonds Date 1/1/2017 Change of Space Use 0 Existing interior lighting systems in areas under -going a change in space use are upgraded to comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2). Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in LTG-INT-BLD or L TG-INT-SPA CE form. Interior and Exterior Lighting Power Interior lighting Parking garage Exterior lighting Lighting Alterations 50% or more of existing are replaced 0 0 0 Select all Lighting Power and Lighting Control elements that apply to the scope Less than 50% of existing are replaced 0 0 0 of the retrofit project. If project includes a Lamp and/or ballast replacement only —existing total wattage not increased combination of spaces where less than 50% of the existing fixtures are replaced in some spaces, and 50% or more of the fixtures are replaced in others, then provide separate lighting power compliance forms for the two retrofit 50% or more replaced - Total lighting power of new + existing -to -remain fixtures shall comply with total LPA per Sections C405.4.2 and C405.5.2. Include new+ existing -to -remain fixtures in Proposed Lighting Wattage table in LTG-INT-BLD, L TG-INT-SPA CE or LTG-EXT form. conditions. Spaces undergoing the same Less than 50% replaced - Total lighting power of new + existing -to -remain fixtures shall not exceed type of retrofit may be combined into one the total lighting power prior to alteration. Include new + existing -to -remain fixtures in the Proposed lighting power compliance form. Lighting Wattage table in LTG-INT-BLD, L TG-INT-SPA CE or LTG-EXT form. 50% threshold applies to numberof luminaires for interior spaces and parking garages, and total Refer to Section C503.6 for additional installed wattage for exterior luminaires. requirements. Lighting Controls Interior lighting Parking garage Exterior lighting All alteration lighting controls shall be commissioned perC408.3. New wiring installed to serve added fixtures and/or fixtures relocated to 0 0 0 new circuit(s) New or moved lighting panel 0 0 0 Interior space is reconfigured - luminaires unchanged or relocated 0 New wiring or circuit - For interior lighting, provide required manual controls per C405.2.3, occupancy sensor controls per C405.2.1, daylight responsive controls per C405.2.4 and application 13 No changes are being made to the interior or exterior lighting systems and existing space specific lighting controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7. New or moved panel - Provide all applicable lighting controls as noted for New Wiring and automatic time switch controls per C405.2.2. uses and configuration are not Reconfigured interior space - Provide all required lighting controls that apply to a new interior changed. space. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured 2015 Washington State Enerqv Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all F Revised Nov 2017 Project Title: Sound Credit Union - Edmonds Date 1/1/2017 Calculation New Construction oAddition - o Addition For Building Department Use NOTES Area stand alone + existing ❑ Spaces where < 50% of Spaces where >_ 50% of ❑ Spaces where the Use luminaires are replaced luminaires are replaced is changing (C505) LPA f♦ Standard ❑ Additional Efficiency Package Option ❑ Calculation C406.3 Reduced Interior Lighting Power User Note Type To comply vuth C406.3, the Proposed LPD shall be 25% lovier than the Target LPA. Refer to C406.3 for additional requirements. Maximum Allowed Lighting WattagWTE 1 Watts Allowed Location (plan #, Gross Interior Allowed (watts/ft2 x area) Building Area room #, or ALL) Area Description Area in ft2 Watts perft2 NOTE Office All Open office, closed offices 2483 0. 66 1639 Total 2483 Proposed Lighting Wattage Building Area Location (plan #, room #) Fixture Description NOTE 3, 4, 5, 6 Number of Fixtures Wafts per Fixture NOTE 7 Watts Proposed Office Open Office/Closed Offices 2x4 recessed fixture (existing) 7 35 245 Office Open Office 2x2 recessed fixture 11 35 385 Office Open Office 6"can 21 35 735 Compliance by Building Area NOTES BuiIdingArea Warnings otal Allowedotal Watts ProposedInterior Watts Lighting Power Allowance Office 1639 1365 COMPLIES Note 1 - List all unique building areas per Table C405.4.2(1) that occur in the Totals 1639 1365 project scope. Select building area category from drop dow7 menu. Note 2 - Unlit Message - Enter lighting fixture information for this building area surface in Proposed Lighting Wattage table to generate Lighting Povier Allovtance. Note 3 - Proposed fixtures must be listed in the building area in which they occur. List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures. Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 5 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank. Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing in fixture description. Note 7 - For proposed Watts/Fixture enter the luminaire vtattage for installed lamp and ballast using manufacturer or other approved source.