REVIEWED BLD BLD2020-1092+Interior_Lighting_Summary+10.15.2020_2.40.51_PM2015 Washington State Enerqv Code Compliance Forms for Commercial Build inqs including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017
Project Info Project Title: Sound Credit Union - Edmonds Date 1/1/2017
Compliance Applicant Information. Provide contact information for individual mho can For Building Department Use
forms do not respond to inquiries about compliance form information provided.
require a Company Name: JPC Architects, LLC BLD2020-1092
password to
use. Company Address: 909 112th Ave NE Suite 206 RECEIVED
Instructional and
calculating cells Applicant Name: Teresa Portman are mrite-Oct19 2020
protected. Applicant Phone: 425-460-2370 CITY OF EDMONDS
carchitects.com DEVELOPMENT SERVICES
Applicant Email: teresap@jpcarchitects.com DEPARTMENT
Project Description
0 New Building 0 Addition 0 Alteration 0 No Lighting Scope
Include PROJ-SUM form (included in envelope forms vtorkbook) vuth lighting compliance forms.
Interior Lighting System
New and Existing light fixture
Description
REVIEWED
BY
0 Interior Lighting Plans Included
CITY OF EDMONDS
Interior Lighting Power
p Building Area Method 0 Space -by -space Method
Allowance Method
Select method used in project.
Interior Lighting Controls
0 All C405.2.1- C405.2.8 Lighting Controls 0 C405.2 Exception 5 Luminaire Level
Lighting Controls (LLLC)
o Additional Efficiency Package Option
C406.4 Enhanced Digital Lighting
To comply vdth C406.4, no less than 90% of the total installed interior lighting poorer shall comply vdth
required controls per C406.4.
Dwelling Unit Interior
Permanently installed interior lighting fixtures in dvielling units comply viith: No Dwelling
Lighting
Units
4 C405.2 thru C405.5 Commercial Lighting Controls and LPA
4 C406.3 High Efficacy Lighting
R404.1 Residential High Efficacy Lighting. Dmelling unit lighting complies vdth WSECResidential
provisions in lieu of WSEC Commercial provisions.
Exterior Lighting System
Existing light fixtures, 2x4 recessed, 2x2 recessed, linear pendants, recessed can lights to
Description
be relamped with LED lamps.
0 Exterior Lighting Plans Included
Building Additions
Compliance Method
Interior lighting
Exterior lighting
Lighting systems in addition area comply with all applicable
provisions as a stand alone new construction project
Refer to Section C502.2.6 for additional
Lighting systems in addition are combined with existing
requirements.
building lighting systems to demonstrate compliance
Addition is combined with existing:
For interior lighting projects, include new + existing -to -remain interior lighting fixture mettage in
Proposed Lighting Wattage table in LTG-INT-BLD or L TG-INT-SPA CE form.
For exterior lighting projects, include new + existing -to -remain exterior lighting fixture wattage in
Proposed Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG-EXT form.
2015 Washington State FnPmv Cnde Cmmnliance Fnrms for Commercial 13uildinas including R2 R3_ R4 nver 3 stnries and all R1 Revised Nnv 2017
Project Title: Sound Credit Union -Edmonds
Date 1/1/2017
Change of Space Use
0 Existing interior lighting systems in areas under -going a change in space use are upgraded to
comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2).
Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage
table in LTG-INT-BLD or L TG-INT-SPA CE form.
Interior and Exterior
Lighting Power
Interior lighting
Parking garage
Exterior lighting
Lighting Alterations
50% or more of existing are replaced
0
0
0
Select all Lighting Power and Lighting
Control elements that apply to the scope
Less than 50% of existing are replaced
0
0
0
of the retrofit project. If project includes a
Lamp and/or ballast replacement only
—existing total wattage not increased
combination of spaces where less than
50% of the existing fixtures are replaced
in some spaces, and 50% or more of the
fixtures are replaced in others, then
provide separate lighting power
compliance forms for the two retrofit
50% or more replaced - Total lighting power of new + existing -to -remain fixtures shall comply with
total LPA per Sections C405.4.2 and C405.5.2. Include new+ existing -to -remain fixtures in
Proposed Lighting Wattage table in LTG-INT-BLD, L TG-INT-SPA CE or LTG-EXT form.
conditions. Spaces undergoing the same
Less than 50% replaced - Total lighting power of new + existing -to -remain fixtures shall not exceed
type of retrofit may be combined into one
the total lighting power prior to alteration. Include new + existing -to -remain fixtures in the Proposed
lighting power compliance form.
Lighting Wattage table in LTG-INT-BLD, L TG-INT-SPA CE or LTG-EXT form.
50% threshold applies to numberof luminaires for interior spaces and parking garages, and total
Refer to Section C503.6 for additional
installed wattage for exterior luminaires.
requirements.
Lighting Controls
Interior lighting
Parking garage
Exterior lighting
All alteration lighting controls shall be
commissioned perC408.3.
New wiring installed to serve added
fixtures and/or fixtures relocated to
0
0
0
new circuit(s)
New or moved lighting panel
0
0
0
Interior space is reconfigured -
luminaires unchanged or relocated
0
New wiring or circuit - For interior lighting, provide required manual controls per C405.2.3,
occupancy sensor controls per C405.2.1, daylight responsive controls per C405.2.4 and application
13 No changes are being made to
the interior or exterior lighting
systems and existing space
specific lighting controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7.
New or moved panel - Provide all applicable lighting controls as noted for New Wiring and
automatic time switch controls per C405.2.2.
uses and configuration are not
Reconfigured interior space - Provide all required lighting controls that apply to a new interior
changed.
space. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured
2015 Washington State Enerqv Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all F Revised Nov 2017
Project Title: Sound Credit Union - Edmonds
Date 1/1/2017
Calculation
New Construction oAddition - o Addition
For Building Department Use
NOTES
Area
stand alone + existing
❑ Spaces where < 50% of Spaces where >_ 50% of ❑ Spaces where the Use
luminaires are replaced luminaires are replaced is changing (C505)
LPA
f♦ Standard ❑ Additional Efficiency Package Option ❑
Calculation
C406.3 Reduced Interior Lighting Power
User Note
Type
To comply vuth C406.3, the Proposed LPD shall be 25% lovier than the Target LPA.
Refer to C406.3 for
additional requirements.
Maximum Allowed Lighting
WattagWTE 1
Watts Allowed
Location (plan #,
Gross Interior
Allowed
(watts/ft2 x area)
Building Area
room #, or ALL)
Area Description
Area in ft2
Watts perft2
NOTE
Office
All
Open office, closed offices
2483
0. 66
1639
Total
2483
Proposed Lighting Wattage
Building Area
Location (plan #,
room #)
Fixture Description NOTE 3, 4, 5, 6
Number of
Fixtures
Wafts per
Fixture NOTE 7
Watts Proposed
Office
Open
Office/Closed
Offices
2x4 recessed fixture (existing)
7
35
245
Office
Open Office
2x2 recessed fixture
11
35
385
Office
Open Office
6"can
21
35
735
Compliance by Building Area NOTES
BuiIdingArea
Warnings
otal Allowedotal
Watts
ProposedInterior
Watts
Lighting
Power Allowance
Office
1639
1365
COMPLIES
Note 1 - List all unique building areas per Table C405.4.2(1) that occur in the Totals 1639 1365
project scope. Select building area category from drop dow7 menu.
Note 2 - Unlit Message - Enter lighting fixture information for this building area surface in Proposed Lighting Wattage table to generate
Lighting
Povier Allovtance.
Note 3 - Proposed fixtures must be listed in the building area in which they occur. List all proposed lighting fixtures including exempt
lighting equipment and existing -to -remain fixtures.
Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if
included).
For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information.
Note 5 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank.
Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as
existing in fixture description.
Note 7 - For proposed Watts/Fixture enter the luminaire vtattage for installed lamp and ballast using manufacturer or other approved source.