Loading...
BLD2021-0827_Manufacturer_Specifications_and_Installation_Instructions_6.14.2021_9.42.10_AM_2247415A*& iew s7itqd&rd® HEATING & AIR CONDITIONING Submittal Split System Heat Pump 4A6H5042H1000A Note: "Graphics in this document are for representation only. Actual model may differ in appearance." TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. December 2016 4A6H5042H-SUB-1 B-EN 4 OUR Ingersoll Rand S H EATING & Al R CONDITIONING SERVICE PANEL ELECTRICAL AND REF COMPONENT CLEARANC PER PREVAILING COD TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524 (5 FEET) ABOVE UNIT. UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 305 (12") FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED. ELECTRICAL SERVI PAN 22.2 (7/8) D LOW 28.6 (1-1/8) DIA. 1 22.2 (7/8) DIA. HOLE II BOX BOTTOM FOR El POW[ LIQUID LINE SERVIC 'E' I.D. FEMALE BR CONNECTION WITH 1/4" SAE FLARE PRESSURE TAP FITTINGS. GAS LINE 1/4 TURN BALL SERVICE VALVE, 'D" I.D. FEMALE BRAZED CONNECTION WITH 1/4' SAE FLARE PRESSURE TAP FITTING. Model Base A B C D E F G H J K 4A6H5042H 4 1147 946 870 7/8 3/8 152 98 219 86 813 (45-1/8) (37-1/4) (34-1/4) (6) (3-7/8) (8-5/8) (3-3/8) (32) SOUND POWER LEVEL Model A -Weighted Sound Power Level [dB(A) ] Full Octave Sound Power [dB] 63 Hz* 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4A6H5042H 72 77 75 72 70 67 62 59 52 Note: Rated in accordance with AHRI Standard 270-2008 *For reference only. 4A6H5042H-SUB-1 B-EN S H EATING & Al R CONDITIONING Product Specifications OUTDOOR UNIT (a) (b) 4A6H5042H1000A POWER CONNS. — V/PH/HZ (c) 208/230/1/60 MIN. BRCH. CIR. AMPACITY 22 BR. CIR. PROT. RTG. — MAX. (AMPS) 35 COMPRESSOR DURATION-_ SCROLL NO. USED — NO. STAGES I— 1 VOLTS/PH/HZ 208/230/1/60 R.L. AMPS (d)— L.R. AMPS 16.7— 109 FACTORY INSTALLED START COMPONENTS (e) NO (Uses BAYKSKT263) INSULATION/SOUND BLANKET NO COMPRESSOR HEAT NO OUTDOOR FAN PROPELLER DIA. (IN.) — NO. USED 26.6 — 1 TYPE DRIVE — NO. SPEEDS DIRECT— 1 CFM @ 0.0 IN. W.G. M 4171 NO. MOTORS — HP 1-1/5 MOTOR SPEED R.P.M. 850 VOLTS/PH/HZ 200/230/1/60 F.L. AMPS .93 OUTDOOR COIL — TYPE SPINE FINT ROWS—F.P.I. 2-24 FACE AREA (SQ. FT.) 29.15 TUBE SIZE (IN.) 3/8 REFRIGERANT CONTROL EXPANSION VALVE REFRIGERANT LBS. — R-410A (O.D. UNIT) (g) 10 LBS., 5 OZ FACTORY SUPPLIED YES LINE SIZE — IN. O.D. GAS (h) (i) 7/8 LINE SIZE — IN. O.D. LIQ. 3/8 CHARGING SPECIFICATIONS SUBCOOLING 8°F DIMENSIONS H X W X D CRATED (IN.) 51 x 35.1 x 38.7 WEIGHT SHIPPING (LBS.) 277 NET (LBS.) 227 (a) Certified in accordance with the Air -Source Unitary Air -conditioner Equipment certification program, which is based on AHRI standard 210/240. (b) Rated in accordance with AHRI standard 270. W Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers or fuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. (e) No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter. Optional kit shown. M Standard Air — Dry Coil — Outdoor (9) This value approximate. For more precise value see unit nameplate. (h) Reference the outdoor unit ship -with literature for refrigerant piping length and lift guidelines. Reference the refrigerant piping software pub # 32-3312-xx or refrigerant piping application guide SS- APG006-xx for long line sets or specialty applications (xx denotes latest revision). 0) Trane outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit and 15 feet of tested connecting lines. If connecting line length exceeds 15 feet, then final refrigerant charge adjustment is necessary. Each additional foot over 15 feet requires 0.6 ozs of refrigerant. See the Installer's Guide for full charging instructions. 4A6H5042H-SUB-1 B-EN l�cP�`Ic�rti! s7 iw HEATING & AIR CONDITIONING Mechanical Specification Options General The Outdoor Units are fully charged from the factory for up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 1995. Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather -resistant powder paint finish on all louvered panels and the fan top panel. The corner panels are prepainted. All panels are subjected to our 1,000 hour salt spray test. The base is made of a CMBP-G30 weatherproof material to resist corrosion. Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and high pressure switch. High and low pressure controls are inherent to the compressor. A factory supplied liquid line drier is standard. Some models may require field installation. A*M Wff SAwdwde HEATING & AIR CONDITIONING Compressor The compressor features internal over temperature, pressure protection and total dipped hermetic motor. Other features include: Centrifugal oil pump and low vibration and noise. Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured, this system has a cooling capacity to 55°F. The addition of an evaporator defrost control permits operation to 40°F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 30°F. Thermostats —Cooling only and heat/cooling (manual and automatic change over). Sub -base to match thermostat and locking thermostat cover. Evaporator Defrost Control — See Low Ambient Cooling. 041TSus TE Intertek Globally Recognized. Industry Respected. Ingersoll Rand (NYSE:IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands —including Club Caro, Ingersoll Rand®, Thermo King® and Trane@—work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and efficiency. We are a global business committed to a world of sustainable progress and enduring results. For more information, visit www.ingersollrand.com. Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. The AHRI Certified mark indicates Ingersoll Rand participation in the AHRI Certification program. For verification of individual certified products, go to www.ahridirectory.org. (D2016 Ingersoll Rand All rights reserved 4A6H506H5042H-SUB-SUB-16-EN 01 Dec2016 ,../ Ingersoll Rand 4A6H5042H-SUB-IA-EN (August 2016)