Loading...
BLD2021-0862_Manufacturer_Specifications_and_Installation_Instructions_6.21.2021_12.31.36_PM_2260734Job Name: System Reference: Date: Indoor Unit: MSZ-HM18NA Outdoor Unit: ❑ MUZ-HM18NA-U1 ❑ MUZ-HM18NA-U2 Wireless Remote Controller mnwo ,I��llIliilillllli��h III����IIIIIIIIIIIIIIIIIIIIIII �IIIIIIIIIIIIIIIIII���IIIIIIIIII °i�a��lllllllllllllu��l�' • � S GENERAL FEATURES • Four fan speed options: Low, Medium, High, Super -high • Anti -mold filter • INVERTER -driven compressors and electronic LEVs provide higher efficiency with controlled power usage • The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns • Cooling operation range: 14' F to 115' F • Heating operation range: -4° F to 75° F • Multiple control options available: - Hand-held Remote Controller (provided with unit) - kumo cloud° smart device app for remote access - Third -party interface options - Wired or wireless controllers • 12-hour timer • ECONO COOL mode • AUTO restart • Blue Fin anti -corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Maximum Capacity BTU/H 18,000 Rated Capacity BTU/H 17,200 Minimum Capacity BTU/H 5,800 Cooling Maximum Power Input W 2,028 Rated Power Input W 1,640 Moisture Removal Pints/h 2.1 Sensible Heat Factor 0.86 Power Factor % 98 / 98 Maximum Capacity BTU/H 2O,900 Rated Capacity BTU/H 18,000 Heating 47°F2 Minimum Capacity BTU/H 5,400 at Maximum Power Input W 2,208 Rated Power Input W 1,590 Power Factor % 98 / 97 Maximum Capacity BTU/H 15,000 Heating 17°F3 Rated Capacity BTU/H 11,500 at Maximum Power Input W 1,908 Rated Power Input W 1,300 Heating 5°F4 Maximum Capacity BTU/H 12,780 at Maximum Power Input W 1770 SEER 18.0 EERI 10.5 Efficiency HSPF (IV) 10.0 COP at 47°FZ 3.32 COP at 17°F in Maximum Capacity3 2.30 COP at 5°F in Maximum Capacity4 2.12 ENERGY STAR® certified units (ENERGY STAR products are third -party certified by an EPA -recognized Certification Body.) NO Voltage, Phase, Frequency 208/230V, 1 phase, 60Hz Guaranteed Voltage Range V AC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 V AC 208 / 230 Electrical Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating (SCCR) kA 5 Recommended Fuse/Breaker Size (Outdoor) A 15 Recommended Wire Size (Indoor - Outdoor) AWG 14 MCA A 1 MOCP A 15 Blower Motor Full Load Amperage A 0.67 Indoor Unit Blower Motor Output W 30 Airflow Rate at Cooling, Dry CFM 625-530-431-328 Airflow Rate at Cooling, Wet CFM 562-477-388-295 Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Airflow Rate at Heating, Dry CFM 625-530-431-307 Sound Pressure Level (Cooling) dB(A) 47-42-37-30 Sound Pressure Level (Heating) dB(A) 47-42-37-30 Drain Pipe Size In. (mm) 5/8 (15.88) Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.0Y 9.2/0.2 Unit Dimensions W: In. (mm) 36-5/16 (923) D: In. (mm) 12 (250) H: In. (mm) 9-13/16 (305) Package Dimensions W: In. (mm) 39 (990) D: In. (mm) 13 (330) H: In. (mm) 15 (380) Unit Weight Lbs. (kg) 28 (13) Package Weight Lbs. (kg) 33 (15) Indoor Unit Operating Cooling Intake Air Temp (Maximum / Minimum)* °F 90 DB, 73 WB / 67 DB, 57 WB Temperature Range Heating Intake Air Temp (Maximum / Minimum) °F 80 DB / 70 DB MCA A 10 MOCP A 15 Fan Motor Full Load Amperage A 0.5 Fan Motor Output W 55 Airflow Rate CFM 1,243 / 1,229 Refrigerant Control LEV Defrost Method Reverse cycle Heat Exchanger Type Plate fin coil Sound Pressure Level, Coolingi dB(A) 50 Sound Pressure Level, Heating2 dB(A) 51 Compressor Type DC INVERTER -driven Twin Rotary Compressor Model SNB130FQBMT Outdoor Unit Compressor Rated Load Amps A 7.4 Compressor Locked Rotor Amps A 9.3 Compressor Oil Type // Charge oz. FV50S // 11.8 External Finish Color Munsell 3Y 7.8/1/1 Base Pan Heater Optional Unit Dimensions W: In. (mm) 31-1/4 (800) D: In. (mm) 11-1/6 (285) H: In. (mm) 21-5/10 (550) Package Dimensions W: In. (mm) 37 (940) D: In. (mm) 14-15116 (380) H: In. (mm) 24-13/16 (630) Unit Weight Lbs. (kg) 81 (37) Package Weight Lbs. (kg) 88 (40) Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Cooling Air Temp (Maximum / Minimum)* °F 115 / 14 Outdoor Unit Operating Cooling Thermal Lock -out / Re -start Temperatures** °F -1 / 3 Temperature Range Heating Air Temp (Maximum / Minimum) °F 75 / -4 Heating Thermal Lock -out / Re -start Temperatures** °F -9 / -4 Refrigerant Type R410A Charge Lbs, oz 2,10 Gas Pipe Size O.D. (Flared) In. (mm) 1/2 (12.7) Liquid Pipe Size O.D. (Flared) In. (mm) 1/4 (6.35) Piping Maximum Piping Length Ft. (m) 65 (20) Maximum Height Difference Ft. (m) 40 (12) Maximum Number of Bends 10 Notes AHRI Rated Conditions 'Cooling (Indoor H Outdoor) °F 80 DB, 67 WB H 95 DB, 75 WB (Rated data is determined at a fixed 2Heating at 47°F (Indoor H Outdoor) °F 70 DB, 60 WB H 47 DB, 43 WB compressor speed) 3Heating at 17°F (Indoor H Outdoor) °F 70 DB, 60 WB H 17 DB, 15 WB Conditions 4Heating at 5*F (Indoor H Outdoor) °F 70 DB, 60 WB H 5 DB, 4 WB *Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Anti -allergy Enzyme Filter ❑ MAC-408FT-E Remote Controller Holder ❑ U01A01083 kumo touchTm RedLINKTM Wireless Controller ❑ MHK2 Deluxe MA Remote Controllers ❑ PAR-40MAAU Simple MA Controller' ❑ PAC-YT53CRAU-J Touch MA Controller) ❑ PAR-CT01 MAU-SB Wired Remote Sensor ❑ M21-EAA-307 Wireless Temperature and Humidity Sensor ❑ PAC-USWHS003-TH-1 System Control Interface ❑ MAC-3341F-E Wireless Interface 2 ❑ PAC-USWHS002-WF-2 Thermostat Interface ❑ PAC-US444CN-1 kumo station® ❑ PAC-WHS01HC-E USNAP Interface ❑ PAC-WHS01UP-E IT Extender ❑ PAC-WHS011E-E BACne& and MODBUS® Interface ❑ PAC-UKPRC001-CN-1 Lockdown Bracket for Hand-held Remote Controllers ❑ RCMKP1CB Blue Diamond Sensor Extension Cable —15 Ft. ❑ C13-103 Blue Diamond Alarm Extension Cable —6.5 Ft. ❑ C13-192 Blue Diamond MultiTank—collection tank for use with multiple pumps ❑ C21-014 Blue Diamond Rubber Foot Pads ❑ F10-010 Mini Condensate Pump —230 volt application ❑ S130-230 MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor ❑ X87-835 - 110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (110V) up to 48,000 BTU/ H[recommended] ❑ X87-711 - 110V Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] ❑ X87-721 - 208/230V MicroBlue Blue Diamond Mini Condensate Pump (110/208/230V) up to 18,000 BTU/H ❑ X85-003 Fascia Kit for MicroBlue Pump — mounts the MicroBlue and sensor directly beneath the indoor unit ❑ T18-016 Drain Pan Level Sensor ❑ SS610E (30A/600V/UL) [fits 2" X 4" utility box] - Black ❑ TAZ-MS303 (30A/600V/UL) [fits 2" X 4" utility box] - White ❑ TAZ-MS303W 1 Requires MAC-3341F-E 2 Allows indoor units to connect to an MA Controller Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Outlet Guide ❑ MAC-881 SG Drain Socket ❑ MAC-860DS Optional Defrost Heater ❑ MAC-640BH-U Hail Guard ❑ HG-B4 Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic ❑ DSD-400P Condensing Unit Mounting Pad 16" x 36" x 3" ❑ ULTRILITE1 Outdoor Unit Stand —12" High ❑ QSMS1201 M Outdoor Unit Stand —18" High ❑ QSMS1801 M Outdoor Unit Stand —24" High ❑ QSMS2401M Heavy Duty Wall Mounting Bracket —Coated Steel ❑ QSWB2000M-1 Heavy Duty Wall Mounting Bracket —316 Series Stainless Steel ❑ QSWBSS 15' x 1/4" x 15' / 1/2" Lineset (Twin -Tube Insulation) ❑ MLS141212T-15 30' x 1/4" x 30' / 1/2" Lineset (Twin -Tube Insulation) ❑ MLS141212T-30 50' x 1/4" x 50' / 1/2" Lineset (Twin -Tube Insulation) ❑ MLS141212T-50 65' x 1/4" x 65' / 1/2" Lineset (Twin -Tube Insulation) ❑ MLS141212T-65 100' x 1/4" x 100' / 1/2" Lineset (Twin -Tube Insulation) ❑ MLS141212T-100 Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 36-5/16 1/4 Capacity in 18 KBTU/H Capacity in 24 KBTU/H rn Insulation 02 O.D n Li uid line 05/16 15-3/8 Flared connection 01/4 'a Gas line 015/32 13-3/8 Flared connection 01/2 Drain hose Insulation 01-1/8 Connected part 05/8 O.D Unit: inch rn Insulation 02 O.D o. Liquid line 05/16 15-3/8 (Flared connection 03/8) a Gas line 015/32 13-3/8 Flared connection 05/8 Drain hose Insulation 01-1/8 Connected part 05/8 O.D Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Unit: inch REQUIRED SPACE *1 4 in. or more when front and sides of the unit are clear F-1-1 It Air in r, Drain hole 01-21/32 ; Air in ' c p( We+2 r��n Or L m rn 9 �� �0 :� r� rn — O i m C *2 When any 2 sides of left, right 1-9/16 and rear of the unit are clear air our 2-holes 3/8x13/16 Service Danel a u- n FORM# MSZ-HM18NA / MUZ-HM18NA - 202003 Liquid refrigerant pipe joint Refrigerant pipe (flared) o 1/4 N N m1 Gas refrigerant pipe joint Refrigerant pipe (flared) o 3/8 (09/12 KBTU/H) `n rno 1/2 (15/18 KBTU/H) 5-11/32 6-23/32 1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com ETA �s Intertek Specifications are subject to change without notice. © 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.