510 8 AVE N-SITE PLANGENERAL NOTES:
1.0 GENERAL
0
s
THESE STRUCTURAL NOTES SUPPLEMENT THE SPECIFICATIONS, ANY
DISCREPANCY FOUND AMONG THE DRAWINGS, SPECIFICATIONS, THESE NOTES,
AND THE SITE CONDITIONS SHALL BE REPORTED TO THE OWNER, WHO
SHALL CORRECT SUCH DISCREPANCY IN WRITING. ANY WORK DONE BY THE
CONTRACTOR AFTER DISCOVERY OF SUCH DISCREPANCY SHALL BE DONE AT THE
CONTRACTOR'S RISK THE CONTRACTOR SHALL VERIFY AND COORDINATE THE
DIMENSIONS AMONG ALL DRAWINGS PRIOR TO PROCEEDING WITH ANY WORK OR
FABRICATION. THE CONTRACTOR IS RESPONSIBLE FOR ALL BRACING AND
SHORING DURING CONSTRUCTION.
1.1 CODES
ALL METHODS, MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE
REQUIREMENTS OF THE CITY OF EDMONDS. 2012 INTERNATIONAL RESIDENTIAL CODE
(IRC), AS AMENDED AND ADOPTED BY THE CITY OF EDMONDS AND THE STATE OF
WASHINGTONt A.G.I. 318, A.IS.C. 9TH EDITION, AND A.I.T.C. 3RD
EDITION.
1.2 DESIGN CRITERIA
A. LIVE LOADS
ROOF (SNOW) 25 PSF
FLOOR RES 40 PSF
FLOOR DECKS (00 PSF
B. LATERAL LOADS:
WIND DESIGN CRITERIA:
1. BASIC WIND SPEED 85 mph
2. WIND IMPORTANCE, I W = 1.00 (CATEGORY II)
3. WINDOW EXPOSURE 'B'
4. INTERNAL PRESURE COEFFICIENT N/A (SIMPLIFIED WIND LOAD METHOD - 1609b)
5. COMPONENTS AND CLADDING
ZONE
POSITIVE
PRESSURE
NEGATIVE
PRESSURE
1
11.9 PSF
-133 PSF
2
11.9 PSF
-152 PSF
2 (OVERHANG)
-24.1 PSF
3
11.9 PSF
-152 PSF
3 (OVERHANG)
-24.1 PSF
4
13.0 PSF
-14.1 PSF
5
13.0 PSF
-11A PSF
TOPOGRAPHIC EFFECT FACTOR K =1.0 TZ
SEISMIC DESIGN CRITERIA:
1. SEISMIC IMPORTANCE, le = 1.0 SEISMIC USE GROUP 1
2. MAPPED SPECTRAL RESPONSE ACCELARATIONS S =155% Sd = 545,
3. SITE CLASS : D
4. SITE RESPONSE COEFFICIENTS: S ds = 1.03% S dl =545
5. SEISMIC DESIGN CATEGORY: D
6. BASIC SEISMIC -FORCE -RESTING SYSTEM: BEARING WALL SYSTEM
1. DESIGN BASE SHEAR: 18.8 KPS
8. SEISMIC RESPONSE COEFFIENTS: Cs -0.14
9. RESPONSE MODIFICATION FACTOR: R=65
10. SIMPLIFIED SEISMIC ANALYSIS RPOCEDURE
1.3 SOIL DATA
FOR LOCATIONS SEE SOILS REPORT. SOIL BEARING 9 CONT. SPREAD
FOOTINGS = 2000 PSF. ALLOW 33-1/3% INCREASE FOR LOADS FROM WIND OR
SEISMIC ORIGIN. EQUIVALENT FLUID ACTIVE PRESSURE AND PASSIVE
PRESSURE ARE 35 PCF AND 300 PCF, RESPECTIVELY.
2.0 SITE WORK
2.1 EXCAVATION
EXCAVATE FOR FOOTINGS DOWN TO DEPTH SHOWN ON DRAWINGS OR TO FIRM
UNDISTURBED MATERIAL. AREAS OVER -EXCAVATED SHALL BE BACKFILLED
WITH LEAN CONCRETE (P'c = 2000 PSI), OR BE STRUCTURALLY FILLED PER
SECTION 22 AND SHALL BE AT THE CONTRACTOR'S EXPENSE.
2.2 BACKFILL AND COMPACTION
BACKFILL SHALL NOT BE PLACED UNTIL AFTER THE REMOVAL OF ALL FORMS,
SCREEDS, OTHER WOOD DEBRIS AND MATERIAL SUBJECT TO ROT OR
CORROSION. USE ONLY MATERIALS APPROVED FOR BACKFILL . IN AREAS
UNDER SLABS OR FOOTINGS, MATERIAL SHOULD BE GRANULAR IN NATURE,
PLACED IN 6-INCH LIFTS AND COMPACTED TO AT LEAST 95% OF MAXIMUM DRY
DENSITY AS DETERMINED BY AASHTO COMPACTION TEST, PROCEDURE T-180.
THE FILL SHOULD BE LIMITED TO GLEAN, GRANULAR MATERIAL.
3.0 CONCRETE 5 SACKS OF CONCRETE PER CUBIC YARD
3.1 GENERAL
ALL CONCRETE SHALL BE HARD ROCK CONCRETE MEETING REQUIREMENTS FOR
"ULTIMATE STRENGTH TYPE CONCRETE", PER ACI 301, "SPECIFICATIONS FOR
STRUCTURAL CONCRETE FOR BUILDING." PROPORTIONING OF INGREDIENTS FOR
EACH CONCRETE MIX SHALL BE BY METHOD 2 OR THE ALTERNATE PROCEDURE
GIVEN IN ACI 301. PLACE CONCRETE PER ACI-304 AND CONFORM TO
ACI-604(306) WINTER CONCRETING AND ACI-605(305) FOR HOT WEATHER
CONCRETING. CONCRETE SHALL BE PLACED TO AVOID SEGREGATION,
HONEYCOMBING OR POCKETS. USE INTERIOR MECHANICAL VIBRATORS WITH
1000 RPM MINIMUM FREQUENCY. DO NOT OVER -VIBRATE. CONCRETE SHALL
BE POURED MONOLITHICALLY BETWEEN CONSTRUCTION OR CONTROL JOINTS.
PROTECT ALL FRESHLY PLACED CONCRETE FROM PREMATURE DRYING AND
EXCESSIVE HOT OR COLD TEMPERATURES FOR SEVEN DAYS AFTER POURING.
PROVIDE ENGINEER WITH PROPOSED CONSTRUCTION OR CONTROL JOINT
LOCATIONS FOR HIS APPROVAL, OR USE JOINTS AS SHOWN ON THE DRAWINGS.
ALL TIES AND ANCHORS SHALL BE CUT OFF FLUSH WITH THE SURFACEt
SURFACES WHERE EXPOSED SHALL BE SMOOTH AND FREE FROM
IRREGULARITIES.
3.2 STRENGTH
TWENTY-EIGHT DAY COMPRESSIVE STRENGTHS SHALL BE:
SLABS ON GRADE : 2000 PSI MAX SLUMP 3" (UNSUPERVISED)
FOOTING # WALLS: 2000 PSIt MAX SLUMP 4" (UNSUPERVISED)
THESE SLUMPS MAY BE INCREASED IF A PROPER ADDITION OF POZZOLITH
IS ADDED TO ALLOW HIGHER SLUMP AND GREATER WORKABILITY WITHOUT
CHANGING THE WATER CONTENT OF THE ORIGINAL MIX DESIGN.
PROPORTION MIX ACCORDING TO IRC n04.
3.3 MATERIAL: MATERIAL: CEMENT, WATER < AGGREGATES PER ACI 301
A. CEMENT MUST CONFORM TO ASTM 150, TYPE I OR TYPE II. ENGINEER'S
APPROVAL IS REQUIRED FOR USE OF TYPE III CEMENT.
B. WATER TO BE CLEAN AND POTABLE.
C. COARSE AND FINE AGGREGATES TO CONFORM TO A6TM-G33.
3.4 MATERIALS
A. WATER REDUCING ADMIXTURES: MUST CONFORM TO ASTM-C494, POZZOLITH
344N, POZZOLITH 100XR, OR POZOLITH 122HE. POZZOLITH SHALL BE
INCORPORATED INTO ALL CONCRETE IN EXACT ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTIONS "SYNERGIZED PERFORMANCE SYSTEMS"
CONCRETE USING POZZOLITH ADMIXTURES TO PRODUCE FLOWABLE
CONCRETE MAY BE USED WITH THE ENGINEER'S APPROVAL. ADMIXTURES
AND DOSAGES WILL VARY DEPENDING ON CLIMATIC CONDITIONS AND THE
CONTRACTOR'S J0561TE REQUIREMENTS. MAXIMUM SLUMP FOR
"SYNERGIZED PERFORMANCE SYSTEMS" CONCRETE SHALL NOT EXCEED 6".
USE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.
B. AIR ENTRAINMENT: CONFORM TO ASTM-C260 AND ASTM-C494, M5-AE-10
BY MASTER BUILDER ENTRAIN 59. +/- 19. AIR BY VOLUME IN ALL
EXPOSED CONCRETE.
C. OTHER ADMIXTURE: NO OTHER ADMIXTURES PERMITTED UNLESS PRIOR
APPROVAL IS GIVEN BY THE ENGINEER
3.5 REINFORCING STEEL
DETAIL, FABRICATE AND PLACE PER ACI-315 AND ACI-318. SUPPORT
REINFORCEMENT WITH APPROVED CHAIRS, SPACERS, OR TIES.
A. STEEL REINFORCEMENT SHALL BE NEW, DEFORMED BILLET STEEL,
MEETING ASTM A615, GRADE 60 FOR 05 AND LARGER
BARS, EXCEPT AS NOTEDt GRADE 40 FOR 04 AND SMALLER BARS. SHOP
DRAWINGS SHALL BE MARKED ACCORDINGLY AND SUBMITTED TO THE I
ENGINEER FOR REVIEW PRIOR TO FABRICATION. GRADE 60 REBARS
SHALL NOT BE BENT IN FIELD AFTER PLACING.
B. REINFORCEMENT IN ALL WALLS, SLABS, AND FOOTINGS SHALL BE
CONTINUOUS AROUND CORNERS OR CORNER BARS PROVIDED, BOTH
VERTICAL AND HORIZONTAL.
C. LAPS: ALL TENSION SPLICES ARE ACCORDING TO ACI 318-89, CLASS B
AND ALL COMPRESSION SPLICES ARE 30 DIAMETERS, UNLESS NOTED
OTHERWISE.
D. TRIM REINFORCING: AROUND ALL OPENINGS SHALL BE A MINIMUM 1-05
TOP AND BOTTOM, EXTENDING 2'46" BEYOND OPENING AT EACH CORNER
SEE TYPICAL DETAILS.
E. WELDING: TACK WELDING OF REBAR IS NOT PERMITTED UNLESS CALLED
F. MINIMUM REINFORCING: WHERE REINFORCEMENT IS NOT SHOWN ON
DRAWINGS, THE "BUILDING CODE REQUIREMENTS FOR REINFORCED
CONCRETE" (ACI 318-89) SHALL BE REFERRED TO FOR PROPER
REINFORCEMENT.
G. REBAR COVER: PROVIDE CONCRETE PROTECTION FOR REINFORCEMENT AS
FOLLOWS: I
3" CONCRETE DEPOSITED AGAINST EARTH
2" CONCRETE DEPOSITED AGAINST FORMS BUT EXPOSED TO EARTH
1-1/2" TO TIES IN COLUMNS, AND TIED REBAR IN WALLS
1-1/2" FOR BARS IN SLABS ON GROUND
3/4" INTERIOR FACE OF WALLS
H. WELDED WIRE FABRIC: ASTM-A185 AND ASTM-A82
J. MINIMUM STEEL REQUIREMENTS FOR CONCRETE WALL USING 04 REBAR
HEIGHT VERTICAL HORIZONTAL
0'-6' IS" O.G. 18" O.C.
6'-9' 16" O.G. 10" O.C.
3.6 FOUNDATION ANCHOR BOLTS
5/6" STEEL BOLTS, WITH 1" MIN. EMBEDMENT INTO CONCRETE. PROVIDE A MIN.
OF (2) BOLTS PER SILL PLATE. ANCHOR BOLTS SHALL BE PLACED AT 12" O.G.
FOR ONE STORY, 48" O.G. FOR TWO STORY RESIDENCES AND REFER TO
LATERAL ENGINEERING FOR THREE STORY RESIDENCES. ADDITIONALLY, ONE
BOLT MUST BE NO LESS THAN 1" FROM EACH END OF EACH INDIVIDUAL SILL PLATE.
ANCHOR BOLT WASHERS MUST BE A MINUMUM OF 3"x3" (SQUARE) x 3/16" (THICKNESS)
4.0 CARPENTRY
4.1 ROUGH CARPENTRY
ALL 2x FRAMING LUMBER SHALL BE STUD GRADE DOUG-FIR FOR STUDS AND
STANDARD OR BETTER FOR PLATES OR AS SHOWN ON THE DRAWINGS OR BELOW.
ALL 2" LUMBER SHALL BE KILN DRIED (KD) OR SURFACE DRIED (SD). EACH
PIECE OF LUMBER SHALL BEAR THE STAMP OF THE WEST COAST LUMBER
MATERIALS B SHOWN BELOW GRADE MARK OR APPROVED EQUAL. OTHER I (2 1 " W TER
2x a 3x STUDS - STUD GRADE DOUG-FIR M E R S 0 BE
2x JOISTS - *1 DOUG-FIR I N S T D BY CITY
4x444x6COLUMNS -01DOUGLAS FIR -------------
bx HEADERS - *1 DOUGLAS FIR
4xHEADERS - 02 DOUGLAS FIR -------------
ALL EXPOSED MATERIALS OR MATERIAL IN CONTACT WITH CONCRETE
SHALL BE PRESSURE TREATED.
4.3 CARPENTRY HARDWARE
A. BOLTS SHALL BE ASTM A-301.
B. WASHERS SHALL BE MALLEABLE IRON WASHERS(MIN). I EXISTING POWER
C. NAILS SHALL BE COMMON, AMERICAN OR CANADIAN MANUFACTURER ONLY. POLE
D. LAG SCREWS, SHEAR PLATES - SEE NATIONAL DESIGN SPECIFICATION.
E. ANCHORS AND CONNECTORS SHALL BE SIMPSON, TECO, BOWMAN OR OTHER TOP SS MANHOLE # 2�
ICBO APPROVED. I DATUM PT.
F. PROTECTION HARDWARE EXPOSED TO WEATHER OR TO VIEW OR IN
UNHEATED PORTION OF BUILDING SHALL BE GALVANIZED. RIM 95.5
4.4 MINIMUM NAILING - PER 2012 IRC INV 92.75
4.5 GLUE -LAMINATED TIMBER
ALL STRUCTURAL GLUE -LAMINATED TIMBER, MATERIALS, MANUFACTURE AND
QUALITY CONTROL SHALL BE IN CONFORMANCE WITH VOLUNTARY PRODUCT
STANDARD PS56 "STRUCTURAL GLUED LAMINATED TIMBER", AND ALL
MEMBERS SHALL BE MARKED WITH A QUALITY MARK THEREOF. ALL PLIES
SHALL BE DOUGLAS FIR COAST REGION. CAMBERS ARE AS SHOWN ON THE
DRAWINGS. ALL MEMBERS SHALL BE EITHER COMBINATION 24F-V4 (SIMPLE
SPAN) OR 24F-V8 (CANTILEVERED OR CONTINUOUS SPAN) AS APPLICABLE.
ALL MEMBERS SHALL BE INDUSTRIAL APPEARANCE AND SHALL BE GLUED WITH
WATERPROOF ADHESIVE PER P.S. 56, ARCHES SHALL BE COMBINATION
24F-V8 AND HAVE EXTERIOR GLUE, ARCHITECTURAL GRADE.
5.0 MISCELLANEOUS
VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO PROCEEDING. PROVIDE
ERECTION BRACING AS NECESSARY UNTIL PERMANENT SUPPORT AND STIFFNESS
ARE INSTALLED. REFER TO ARCHITECTURAL PLANS FOR WALL OPENING,
ARCHITECTURAL TREATMENT AND DIMENSIONS NOT SHOWN. REFER TO
MECHANICAL AND ELECTRICAL PLANS FOR SIZE AND LOCATION OF ALL
OPENINGS FOR DUCTS, PIPES, CONDUITS, ETC., NOT SHOWN.
6.0 ENERGY
2012 WASHINGTON STATE ENERGY CODE WINDOWS 30 'U' VALUE
CREDIT 55 DOORS 20 'U' VALUE
2012 WASHINGTON STATE ENEF rGY CODE
CREDIT 55: GAS WATER HEATER TO HAVE
MINIMUM EF OF 0.82
MEDIUM GAS FURNACE
25'-0" 10'-0"
NORTH
SITE PLAN SOT 3
SCALE: 1- -20 0"
M
LOT SLOPE:
FLAT
LOT AREA:
12,017 SQ. FT.
BUILDING LOT COVERAGE:
3.280 SQ. FT./12-017=
14.30'
Cn
C-�-) -K��'- - - - - - - - - -
CD3Ww CO
O O 0
&TORM WATER DETENTION
WAVER SY DON FIENE 0-1/1-1/200-1:
REFER TO 05-05-2009. DISCHARGE DIRECTLY
INTO REGIONAL DETENTION FACILITY JUST WEST
OF SITE WHICH DISCHARGES DIRECTLY INTO
PUGET SOUND.
�CCCEP T ABLE TIGHT SIF
MATERIAL
WR 35
SCH 40
N-12
PR10 HANCC
Applicant shall repair/replace all danMe to
utilities or frontage improvements in City
right-of-way per city standards that Is caused
or occurs during the permitted project
OWNEFJCONTRACTOR IS RESPONSIELc
FOR EROSION CONTROL AND DAMAGE
HEIGHT CALC.
I'1VU1'_)t ul'(HUCJ:
A) 94
B) 93
C) 93
D) 93
AVERAGE = 93.25
MAX HEIGHT = 93.25 +
PROPOSED HEIGHT =
GARAGE GRADES:
A) 9 4.2 5
B) 97
C) 94.25
D) 93
AVERAGE = 94.63
MAX HEIGHT = 94.63 +
PROPOSED HEIGHT =
APPROVED AS NOTED
_ BY ENGaNEERING
Date:__
NO 4 ,o,1N, uJ - Iol�o PoS�b
1Nt-r�_ --(#is Pg_rr_kT. WrUTy
5zu.35 hWt2F07 W/7h�-
&#W-1- &R-f - VCA1 W6f 70(17
901
25 = 118.25'
117.25'
'Gone `y Comer A Flag
Setbacks
Required
-Actual
Front
a
_ :
A< -
Sides
Ic , c
-� 0�� ' 0
Rear
Other
Height
_aS
ai
15 = 109.63'
109.0'
RESUB
fit 12016'�l
i�UIL ING SEPAkcENT
CITY OF EDMONDS
CITY COPY
REISVB
MAR 14 2016
BUILDINS REPAR7,MENT
CITY OF EDMONDS
U
J
J
Cn 0
W N
0
0 00
Z 0)
0
0
j..
Cl)
Z Z
UW♦♦
M=^^
V J
Z
Z Q
W
w
CO
>
WQ
•
Z
coo
U
�
T
W
U) W
SF�F -2d! S j
nr
GENERAL I
SITE PLAN
PROJECT NO.
DESIGN
DRAWN
ISSUE DATE
LATEST REV.