Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
REVIEWED PLN BLD BLD2020-1315+Manufacturer_Specifications_and_Installation_Instructions+12.1.2020_3.24.43_PM
Job Name: System Reference: Date: Indoor Unit: MSZ-GL09NA REVIEWED BY CITY OF EDMONDS Outdoor Unit: MUZ-GL09NA BLD2020-1315 Wireless Remote Controller RECEIVED Dec 03 020 CITY OF EDMONDS DEVELOPMENT SERVICES GENERAL FEATURES DEPARTMENT • Slim wall -mounted indoor units provide zone comfort control • The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns • INVERTER -driven compressor and LEV provide high efficiency and comfort while using only the energy needed to maintain maximum performance • Multiple fan speed options: Quiet, Low, Medium, High, Super -high, Auto • Multiple control options available: Hand-held Remote Controller (provided with unit) kumo cloud® smart device app for remote access Third -party interface options Wired or wireless controllers • Hot -Start Technology: no cold air rush at equipment startup or when restarting after Defrost Cycle • Quiet operation • Smart Set: recalls a preferred preset temperature setting at the touch of a button • Blue Fin anti -corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Maximum Capacity Btu/h 12,200 Rated Capacity Btu/h 9,000 Cooling Minimum Capacity Btu/h W 3,600 1,050 Maximum Power Input Rated Power Input W 585 Moisture Removal Pints/h 1.5 Sensible Heat Factor 0.82 Power Factor % 86 / 86 Maximum Capacity Btu/h 15,590 Rated Capacity Btu/h 10,900 Heating 47°F2 Minimum Capacity Btu/h 4,500 at Maximum Power Input W 1,250 Rated Power Input W 720 Power Factor % 90 / 90 Maximum Capacity Btu/h 10,200 Heating 17°F3 Rated Capacity Btu/h 6,700 at Maximum Power Input W 1,060 Rated Power Input W 630 Heating 5°F4 Maximum Capacity Btu/h 8,170 at Heating at -4°F5 Maximum Power Input W Maximum Capacity Btu/h SEER EER' 850 6,860 24.6 15.4 HSPF (IV) 12.8 Efficiency COP at 47°FZ 4.44 COP at 17°F in Maximum Capacity3 2.82 COP at 5°F in Maximum Capacity4 2.82 ENERGY STAR® Certified (ENERGY STAR products are third -party certified by an EPA -recognized Certification Body.) YES Voltage, Phase, Frequency 208/230V, 1 phase, 60Hz Guaranteed Voltage Range V AC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 V AC 208 / 230 Electrical Voltage: Indoor - Outdoor, S2-S3 V DC 24 Voltage: Indoor - Remote Controller Wireless Type Recommended Fuse/Breaker Size A 15 Recommended Wire Size (Indoor - Outdoor) AWG 14 MCA A 1 MOCP A 15 Indoor Unit Blower Motor Full Load Amperage A 0.76 Blower Motor Output W 30 Airflow Rate at Cooling, Dry CFM 399-321-237-170-145 Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Airflow Rate at Cooling, Wet Airflow Rate at Heating, Dry CFM 364-286-201-134-109 CFM 406-321-237-170-145 Sound Pressure Level (Cooling) dB(A) 43-37-30-22-19 Sound Pressure Level (Heating) dB(A) 43-37-30-22-19 Drain Pipe Size In. (mm) 5/8 (15.88) Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.OY 9.2/0.2 Unit Dimensions W: In. (mm) 31-7/16 (798) D: In. (mm) 9-1/8 (232) H: In. (mm) 11-5/8 (295) Package Dimensions W: In. (mm) 33-1/2 (850) D: In. (mm) 12 (300) H: In. (mm) 14 (350) Unit Weight Lbs. (kg) 22 (10) Package Weight Lbs. (kg) 26 (11.5) Indoor Unit Operating Cooling Intake Air Temp (Maximum / Minimum)* °F 90 DB, 73 WB / 67 DB, 57 WB Temperature Range Heating Intake Air Temp (Maximum / Minimum) °F 80 DB / 70 DB MCA A 9 MOCP A 15 Fan Motor Full Load Amperage A 0.5 Fan Motor Output W 55 Airflow Rate CFM 1,229 / 1,172 Refrigerant Control LEV Defrost Method Reverse cycle Heat Exchanger Type Plate fin coil Sound Pressure Level, Coolingi dB(A) 48 Sound Pressure Level, Heating2 dB(A) 50 Compressor Type DC INVERTER -driven Compressor Model KNB073FRVMC Outdoor Unit Compressor Rated Load Amps A 6.7 Compressor Locked Rotor Amps A 7.7 Compressor Oil Type // Charge oz. FV50S //9.1 External Finish Color Munsell 3Y 7.8/1/1 Base Pan Heater Optional Unit Dimensions W: In. (mm) 31-1/2 (800) D: In. (mm) 11-1/4 (285) H: In. (mm) 21-5/8 (550) Package Dimensions W: In. (mm) 37 (940) 14-15/16 (380) D: In. (mm) H: In. (mm) 24-13/16 (630) Unit Weight Lbs. (kg) 81 (37) Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Package Weight Cooling Air Temp (Maximum / Minimum)* Lbs. (kg) 88 (40) °F 115 / 14 Outdoor Unit Operating Cooling Thermal Lock -out / Re -start Temperatures** °F -1 / 3 Temperature Range Heating Air Temp (Maximum / Minimum) °F 75 / -4 Heating Thermal Lock -out / Re -start Temperatures** °F -9 / -4 Refrigerant Type R410A Charge Lbs, oz 2,5 Gas Pipe Size O.D. (Flared) In. (mm) 3/8 (9.52) Liquid Pipe Size O.D. (Flared) In. (mm) 1/4 (6.35) Piping Maximum Piping Length Ft. (m) 65 (20) Maximum Height Difference Ft. (m) 40 (12) Maximum Number of Bends 10 Notes AHRI Rated Conditions 'Cooling (Indoor H Outdoor) °F 80 DB, 67 WB H 95 DB, 75 WB (Rated data is determined at a fixed 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB compressor speed) 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5*F (Indoor // Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB 5Heating at -4°F (Indoor // Outdoor) °F 70 DB, 60 WB H -4 DB, -5 WB *Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Anti -allergy Enzyme Filter Backlit, Wall -mounted, Wireless Controller Portable Central Controller Wired MA Controller' ❑ MAC-408FT-E ❑ MHK1 ❑ MCCH1 ❑ PAR-33MAA Simple MA Controller) Touch MA Controller) Wired Remote Sensor ❑ PAC-YT53CRAU ❑ PAR-CT01 MAU-SB ❑ M21-EAA-307 Wireless Temperature and Humidity Sensor ❑ PAC-USWHS003-TH-1 Outside Air Sensor for MHK1 ❑ MOS1 System Control Interfacez ❑ MAC-3331F-E Wireless Interface ❑ PAC-USWHS002-WF-1 Thermostat Interface ❑ PAC-US444CN-1 ❑ PAC-WHS01 HC-E kumo station® USNAP Interface ❑ PAC-WHS01 UP-E IT Extender ❑ PAC-WHS011E-E BACnet® and MODBUS® Interface ❑ PAC-UKPRC001-CN-1 Lockdown Bracket for Hand-held Remote Controllers ❑ RCMKP1 CB Blue Diamond Sensor Extension Cable —15 Ft. ❑ C13-103 Blue Diamond Alarm Extension Cable —6.5 Ft. ❑ C13-192 Blue Diamond MultiTank—collection tank for use with multiple pumps ❑ C21-014 Blue Diamond Rubber Foot Pads ❑ F10-010 Mini Condensate Pump —230 volt application ❑ S130-230 MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor ❑ X87-835 - 110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (110V) up to 48,000 Btu/h [recommended] ❑ X87-711 - 110V Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] ❑ X87-721 - 208/230V MicroBlue Blue Diamond Mini Condensate Pump (110/208/230V) up to 18,000 Btu/h ❑ X85-003 Fascia Kit for MicroBlue Pump — mounts the MicroBlue and sensor directly beneath the indoor unit ❑ T18-016 Drain Pan Level Sensor ❑ DPLS2 (30A/600V/UL) [fits 2" X 4" utility box] - Black ❑ TAZ-MS303 (30A/600V/UL) [fits 2" X 4" utility box] - White ❑ TAZ-MS303W 1 Requires MAC-3331F-E 2 Allows indoor units to connect to an MA Controller Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Outlet Guide Drain Socket Optional Defrost Heater ❑ MAC-881 SG ❑ MAC-860DS ❑ MAC-640BH-U Hail Guard ❑ HG-B4 Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic ❑ DSD-400P Condensing Unit Mounting Pad 16" x 36" x 3" ❑ ULTRILITE1 Outdoor Unit Stand —12" High ❑ QSMS1201 M Outdoor Unit Stand —18" High ❑ QSMS1801 M Outdoor Unit Stand —24" High ❑ QSMS2401M Heavy Duty Wall Mounting Bracket —Coated Steel ❑ QSWB2000M-1 Heavy Duty Wall Mounting Bracket —316 Series Stainless Steel ❑ QSWBSS 15' x 1/4" x 15' / 3/8" Lineset (Twin -Tube Insulation) ❑ MLS143812T-15 ❑ MLS143812T-30 30' x 1/4" x 30' / 3/8" Lineset (Twin -Tube Insulation) 50' x 1/4" x 50' / 3/8" Lineset (Twin -Tube Insulation) ❑ MLS143812T-50 65' x 1/4" x 65' / 3/8" Lineset (Twin -Tube Insulation) ❑ MLS143812T-65 Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 1/I6X1 Oblong hol ..le 3-1/8 1 1 Pawiiiiiiiiiii��ml lm iiiiiiiiiiiimiiiiiiiiiiim=iimiiiiiiiiiii�iiiiiiiiiiimm��i 9-I/8 3/I6 Indoor u TT .1 TJ I IN 11 3/4 1-15/16 J �. 24-3/8 _�5-1/8� 2-5/I� 3/4 'I \ M 2-3/16 15/16 1-3/I6 III Air in ID m Unit: inch II hole d lation of - 3/8 O.D id line tF--LGas o1/4 19 - 11/16 (Flared connection o1/4) line o3/8 16 - 15/16 (Flared connection: o3/8 (GL06109112NA), o112 (GL15NA)) Drain hose Insulation of-1/8 O.D Connected part o5/8 O.D Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. REQUIRED SPACE '1 4 in. or more when front and sides of the unit are clear U 15-3/4 v Air in n Drain hole 01-21/32 (09/12/15 Btum) Air in o, O t � t o m o '- o r m n 1-9/16 � Air out 2-holes 3/8x13/16 7/R u- FORM# MSZ-GL09NA / MUZ-GL09NA - 201902 4in O\ /110re Unit: inch 14�1 � more '2 When any 2 sides of left, right and rear of the unit are clear Service Donel Liquid refrigerant pipe joint Refrigerant pipe (flared) o 1/4 Gas refrigerant pipe joint Refrigerant pipe (flared) o 3/8 (09/12 kBtu/h) o 1/2 (15 kBtu/h) 4 MITSUBISHI /_ ELECTRIC COOLING & HEATING % �s Intertek Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.