REVIEWED BLD-BLD2020-1409+Structural_Analysis_or_Calculations+1.11.2021_12.58.51_PM+1983616STRUCTURAL NOTES
O C
(THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS)
nLC1l:AI 1 nAnC
DEAD LOADS:
ROOF 15 PSF
LIVE LOADS:
ROOF (SNOW LOAD) 25 PSF
(LIVE LOADS ARE REDUCED WHERE PERMISSIBLE PER IBC SECTION 1607.10).
LUMBER
ALL GRADES SPECIFIED ARE MINIMUM GRADES REQUIRED. ALL LUMBER SHALL BE IN ACCORDANCE WITH WWPA
GRADING RULES, KILN -DRIED TO MC 19 AND OF THE FOLLOWING MINIMUM STANDARDS:
SIZE CLASSIFICATION
SPECIES
GRADE
Fb (PSI)
Fc (PSI)
SLEEPERS
DOUG-FIR
STUD
700
-
LIGHT FRAMING (STUDS)
HEM -FIR
STUD
675
800
2x JOISTS AND PLANKS
HEM -FIR
#2
850
-
PLATES AND BLOCKING
HEM -FIR
#2
850
-
6x AND LARGER BEAMS AND
STRINGERS
DOUG-FIR
#2
875
-
4x AND SMALLER BEAMS AND
STRINGERS
HEM -FIR
#2
850
-
ALL POSTS AND TIMBERS
DOUG-FIR
1 #1
1 1200
1 1000
REFER TO PLAN NOTES, SCHEDULES, AND DETAILS FOR MORE SPECIFIC LUMBER SIZE AND GRADE REQUIREMENTS.
UNLESS NOTED OTHERWISE IN THE PLANS, ALL WOOD AND WOOD -BASED MEMBERS EXPOSED TO WEATHER OR IN
CONTACT WITH CONCRETE, MASONRY, OR WITHIN 8" OF SOIL SHALL BE PRESERVATIVE -TREATED BY
VACUUM -PRESSURE IMPREGNATION IN ACCORDANCE WITH AWPA STANDARD U1.
NAILS, BOLTS, AND METAL CONNECTORS FOR WOOD
ALL NAILS SHALL CONFORM TO THE STANDARDS SET FORTH BY THE NATIONAL DESIGN STANDARDS (NDS) FOR
WOOD CONSTRUCTION, LATEST EDITION. NAILING NOT SPECIFIED SHALL BE PER IBC TABLE 2304.9.1 NAILING
SCHEDULE. ALL NAILS CALLED OUT ON PLANS SHALL BE COMMON NAILS UNLESS NOTED OTHERWISE AND SHALL
MEET OR EXCEED THE FOLLOWING MINIMUM GUIDELINES:
NAIL
SHANK 0
MIN LENGTH
8d COMMON
0.1310
2 1/2" SHANK
10d COMMON
0.1480
3" SHANK
12d COMMON
0.1480
3 1/4" SHANK
16d COMMON
0.1620
3 1/2" SHANK
10d BOX NAILS MAY BE SUBSTITUTED FOR 8d COMMON NAILS WITH NO CHANGE IN NAIL SPACING. FRAMING
MEMBERS MAY BE NAILED WITH 16d SINKERS (0.148"0 x 3 1/4"), BUT ONLY 16d COMMON NAILS SHALL BE USED
WHERE 16d NAILS ARE INDICATED IN THIS DRAWING SET. ENGINEER MAY APPROVE OTHER NAILS IF NAIL LABELS
ARE SUBMITTED TO ENGINEER PRIOR TO START OF CONSTRUCTION.
ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS
OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. LEAD HOLES FOR LAG BOLTS SHALL BE BORED FOR THE
SHANK AND THREADED PORTIONS PER NDS 11.1.3.
CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, CATALOG
TO BE THE LATEST EDITION, OR ENGINEER APPROVED EQUAL. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE
WITH THE MANUFACTURER'S RECOMMENDATIONS AND WITH THE NUMBER AND SIZE OF FASTENERS AS SPECIFIED
BY THE MANUFACTURER. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS,
SCREWS, OR BOLTS IN EACH MEMBER.
INSTALL SOLID BLOCKING AT ALL BEARING POINTS. ALL SHIMS SHALL BE SEASONED, DRIED, AND THE SAME GRADE
(MINIMUM) AS MEMBERS CONNECTED.
GALVANIZATION
UNLESS NOTED OTHERWISE, STEEL CONNECTORS IN CONTACT WITH TREATED WOOD SHALL BE GALVANIZED
ACCORDING TO THE FOLLOWING TABLE:
GALVANIZATION
UNTREATED
WOOD
CCA-C
SBX
ACQ-C
ACQ-D
CBA-A
CA-B
OTHER
BORATE
ACZA
OTHER PT
WOOD
G90
X
X
X
G185
X
X
X
X
X
X
HDG
X
X
X
X
X
X
STT300
X
X
X
X
X
X
X
X
G90 = 0.90 OZ. OF ZINC PER SQUARE FOOT OF AREA
G185 = 1.85 OZ. OF ZINC PER SQUARE FOOT OF AREA
HDG = HOT DIP GALVANIZED
SST300 = TYPE 316L STAINLESS STEEL
EXISTING BUILDING
CONTRACTOR SHALL VERIFY ALL DIMENSIONS, MEMBER SIZES AND CONDITIONS OF THE EXISTING BUILDING
DEPICTED IN THE DRAWINGS, AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES FOR POSSIBLE
REDESIGN.
CONTRACTOR RESPONSIBLE FOR COMPLETELY SEALING ALL AREAS WHERE EXISTING ROOF MATERIAL IS
PENETRATED OR REMOVED. PROVIDE WATER PROOFING AS REQUIRED BY THE ARCH.
GENERAL
STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL, CIVIL, ELECTRICAL, AND
MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
CONDITIONS FOR COMPATIBILITY BEFORE PROCEEDING. ANY DISCREPANCIES SHALL BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT BEFORE PROCEEDING.
CONTRACTOR TO SEE ARCHITECTURAL, CIVIL, ELECTRICAL AND MECHANICAL DRAWINGS FOR SIZE AND LOCATION
OF PIPE, VENT, DUCT AND OTHER OPENINGS AND DETAILS NOT SHOWN ON THESE DRAWINGS.
CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION STABILITY AND TEMPORARY SHORING AS NECESSARY UNTIL
PERMANENT SUPPORT AND STIFFENING ARE INSTALLED.
CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL
ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS
ONLY WILL NOT SATISFY THIS REQUIREMENT.
DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT
SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF
CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL
ENGINEER.
TI
ROOF FRAMING PLAN
SCALE: 1/4" = V-0"
48 HF#2 HDR
i■ 1■ 1■ 1■ 1■ 1■ 1■ 1■ 1■ 1■ 1■ 1■ 1■ 1■ 1■ 1■ 1■ 1■ 1■ 1■ 1■ 1■ 1■ 1■
■
REVIEWED
■
BY '
CITY OF EDMONDS!
■
■ BUILDING DEPARTMENT
■
i■1■1■1■1■1■1■1■1■1■1■1■1■1■1■1■1■1■1■1■1■1■1■IL
SIMPSON A35 (ONLY
REQUIRED AT EXTERIOR
HEADERS GREATER
THAN 6- SPAN)
(6) 0.131"0 x 3" NAILS
TYPICAL STUDS
NAILING PER TYP
BUILT-UP STUD
COLUMN DETAIL
AT HOLDOWNS: PROVIDE FULL HT
HOLDOWN CHORDS PER HD SCHED.
OTHERWISE: (1) 2x FULL HT
TYP DOUBLE
TOP PLATE
BEAM OR HEADER PER
PLAN AND NOTES
CRIPPLE STUDS PER PLAN
AND COLUMN SCHEDULE OR
STRUCTURAL NOTES
TYPICAL HEADER DETAIL
SCALE: 1" = V-0"
RECEIVED
Jan 11 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
ENGINEERING
250 4TH AVE. S., SUITE 200
EDMONDS, WASHINGTON 98020
PHONE (425) 778-8500
FAX (425) 778-5536