Loading...
APPROVED PLN ENG SITE PLAN BLD2021-0074+1.20.2021_3.03.42_PM+1998663EXIST TYP. EDMONDS WAY APN:00491100001602 DNING: CIS - COMMERCIAL -. EXISTING T-MOBILE EQUIPMENT AREA WITHIN EXISTING ATC COMPOUND (SEE SHEET A-2) I A I I I EXISTING PROPERTY I TYP. (APPROXIMATE) I EXISTING PARKING LOTZ I I APPROVED BY PLANNING EDMONDS WAY EXISTING BUILDING (TYP) LEGA DESCRIPTION: NOT PROVIDED EXISTING PARKING LOT/ EXISTING TREE (TYP) EXISTING 'ARKING LOT /is 244TH ST SW�N 205TH ST 244TH ST SW Feb 23 2021 REC E IVE D SHEET TITLE: ENGINEERING DIVISION Jan 20 2021 OVERALL APPROVED INFORMATION CONTAINED WITHIN DRAWINGS CITY OF EDMONDS SERVICES SITE PLAN IS BASED ON PROVIDED INFORMATION AND IS 01/27/2021 DEVELOPMENT SERVICES NOT THE RESULT OF A FIELD SURVEY. DEPARTMENT SHEET NUMBER: 1 OVERALL SITE PLAN 22"x34"SCALE: 1"=30'-0" A-1 11"x17" SCALE: 1" = 60'-0" 30' 15' 30' T Mobile 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 111L AMERICAN TOWER CORPORATION INFINIGYS' FROM ZERO TO INFINIGY the solutions are endless BELLEVUE, WA 98004 r T-MOBILE SITE: SE01506A FIRDALE / CAMPBELL NELSON/VZW ATC SITE: 414383 SEAQ LAKE BALLINGER WA 24329 HWY 99 EDMONDS, WA 98026 SNOHOMISH COUNTY 90'-0" MONOPOLE DRAWINGS ISSUED FOR: REV. DATE DRAWN DESCRIPTION OA/OC A 12/08/20 RCD PRELIMINARY REVIEW PD B 12/29/20 CAP REVISED PRELIM. REVIEW PD 0 01/06/21 JGB 100% CONSTRUCTION PD REVISION: 0 THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF INFINIGY ENGINEERING, PLLC AND ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF INFINIGY ENGINEERING, PLLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE WRITTEN APPROVAL OF THE PROFESSIONAL OF RECORD INFORMATION CONTAINED WITHIN DRAWINGS EXISTING T-MOBILE ICE IS BASED ON PROVIDED INFORMATION AND IS EXISTING T-MOBILE COAX BRIDGE NOT THE RESULT OF A FIELD SURVEY. CABLES TO REMAIN T Mobile EXISTING T-MOBILE c D PURCELL CABINET TO 19807 NORTH CREEK PKWY N BE REMOVED BOTHELL, WA 98011 EXISTING T-MOBILE 10'-0"xl4'-6" EXISTING T-MOBILE EQUIPMENT CONCRETE PAD � � _ COVP MOUNTED ON EXISTING H-FRAME TO BE REMOVED (1 TOTAL) AMERICAN TOWER CORPORATION EXISTING T-MOBILE ULTRASITE CABINET TO BE REMOVED \ EXISTING T-MOBILE DIPLEXERS MOUNTED = ON EXISTING H-FRAME TO REMAIN (6 TOTAL) INFINIGYS' EXISTING T-MOBILE FCOA CABINET TO BE RELOCATED EXISTING (RELOCATE (1) FSME, (1) ESMC, RATING WALL FROM ZERO TO INFINIGY FXFC & FRIA; ALL OTHER the solutions are endless E EQUIPMENTT TO BE REMOVED) EXISTING EXISTING BUILDING EQUIPMENT ON X k x - x— x— X — X — X— X— X— I BELLEVUE, WA 98004 CONCRETE PADTxx — X — x PROPOSED (BY OTHERS)F T-MOBILE r T-MOBILE SITE: AREA EXISTING UTILITY H (SEEANTSHEET I (SEE SHEET A-4) FRAME (BY OTHERS) I I SE01506A EXISTING T-MOBILE TELCO EXISTING UTILITY H I FIRDALE / CAMPBELL BOX, AC PANEL & GEN PLUG FRAME (BY OTHERS) ® ' EXISTING ATC NELSON/VZW TO BE REMOVED MONOPOLE / ATC SITE: EXISTING T-MOBILE H-FRAME TO REMAIN EXISTING CHAIN LINK 414383 a FENCE W/ BARBED WIRE SEAQ LAKE BALLINGER WA & PRIVACY SLATS (TYP.) ® � Xx Xx Xx Xx Xx Xx = Xx Xx 24329 H WY 99 x x I I EDMONDS, WA98026 3 EXISTING ENLARGED EQUIPMENT PLAN 22"x34" SCALE: 1/2"=1'-0" 11"x17"SCALE: 1/4"=1'-0" 2' 1' 0' �' x EXISTING T-MOBILE EQUIPMENTAREA WITHIN EXISTING EXISTING ACCESS ATC COMPOUND SNOHOMISH COUNTY 90'-0" MONOPOLE � EXISTING T-MOBILE ICE BRIDGE EXISTING T-MOBILE COAX GATE, TYP. I EXISTING WOOD FENCE Q CABLES TO REMAIN x RELOCATED T-MOBILE $� --- PROPOSED T-MOBILE HCS q_5 x FCOA CABINET W/= INGRESS ESMC, (1) FXFC & (3) 2.0 PENDANT STYLE FRIA HYBRID CABLE (2 TOTAL) PROPOSED T-MOBILE HCS 2.0 1 EGRESS / JUNCTION BOX MOUNTED TO EXISTING H-FRAME (2 TOTAL) k + I x —x —x I / HH ❑� T x DRAWINGS ISSUED FOR: REV. DATE DRAWN DESCRIPTION OA/OC A 12/08/20 RCD PRELIMINARY REVIEW PD B 12/29/20 CAP REVISED PRELIM. REVIEW PD 0 01/06/21 JGB 100% CONSTRUCTION PD 1 �_ 1 1 1 Ij PROPOSED T-MOBILE HPL3 SSC W/ NEW CSR IXRE, (2) AMIA WITH EXISTING T-MOBILE ® J BASEBAND MODULES PER RFDS, DIPLEXERS MOUNTED x AND RELOCATED FSME ON EXISTING H-FRAME I TO REMAIN (6 TOTAL) i W PROPOSED T-MOBILE S�4yiAER �F WAs�'Qp. BATTERY CABINET (SEE NOTE BELOW) x PROPOSED T-MOBILE I y A-s A-s.z I 3'-e^ TECH LIGHT EXISTING T-MOBILE 10'-0"xl4'-6" EQUIPMENT CONCRETE PAD - PROPOSED T-MOBILE AA CUBE W/ RELOCATED LEC �� 40190 �4 CM) AS` PROPOSED T-MOBILE ROUTER (COORDINATE W/ I {DNA L ECGC1ST-V EMERSON CAC PPC/LOAD 1 BATTERY NOTE: CENTER AND CAM-LOK—, A-s • PROPOSED BATTERY CABINET W/ EXISTING T-MOBILE STRINGS OF (4) (16 CELLS TOTAL) OF O H-FRAME I RECEIVE SHEETTITLE: VALVE REGULATED LEAD ACID BATTERIES / (VRLA) WITH IMMOBILIZED ELECTROLYTE I Jan 20 2021 ENLARGED TECHNOLOGYAT2.34GALLONS PER CELL TOTAL ELECTROLYTE VOLUME IS 37.44. SITE PLANS GALLONS. AS THE TOTAL ELECTROLYTE CITY OF EDMONDS VOLUME DOES NOT EXCEED 50 GALLONS, DEVELOPMENT SERVICES DEPARTMENT SHEET NUMBER: REVISION: COMPLIANCE WITH INTERNATIONAL FIRE � CODE SECTION 608 IS NOT REQUIRED I ^ L O 2 PROPOSED ENLARGED EQUIPMENT PLAN ENLARGED SITE PLAN 22"x34"SCALE: 3132-1111. ® 111. 11"x17"SCALE: 1/4"=T-0" 2' 1' 0' 2' 11"x17"SCALE: 3/32"=1'-0" 4' 2' 0' 4' THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF INFINIGY ENGINEERING, PLLC AND ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF INFINIGY ENGINEERING, PLLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE WRITTEN APPROVAL OF THE PROFESSIONAL OF RECORD.