APPROVED BLD-BLD2021-0319+Architectural_Plan+3.3.2021_1.28.01_PM+20739667'3"
403ORS 403ORS
403ORS
remove
window
not load bearing
joist direction
Master Bedroom
doubled
2x8 fir joists
16" o.c.
interior bearing wall
(supports roof only)
Walk-in Closet
r10
3068
coo
not load bearing
'S
0
joist direction
doubled
2x8 fir joists
16" o.c.
Master Bath
Bedroom
O SD
above
■ to remove
2ND (TOP) FLOOR PLAt 7027 174th St SW
EXISTING Bedroom Area renovation
March 2021
GARAGE BELOW
100% fire separation drywall coverage
(GARAGE SEPARATION REQUIRES'/2" ■
■GYPSUM WALL BOARD ON THE GARAGE
(SIDE. 5/8" TYPE "X" GYPSUM WALL BOARD IS
.REQUIRED WHERE THERE IS LIVING SPACE I
(ABOVE. SUPPORTING COLUMNS, WALLS ■
■AND BEAMS USE'/2" GYPSUM WALL BOARD I
�I RC R302.6 ■
APPROVED
PLANS MUST BE
ON JOB SITE
City of Edmonds
Building Department
APPROVED Plans
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
City Of Edmonds
Building Department
Work REMODEL
Address 7027 174TH ST SW
----------------------------------------
Owner STINSON
--------------------------------------------
Approved Date 3/11 /202'
Building Official 4661p/� 1510oxh;
Permit Number BLD2021-0319
Property Owner/ D. GRAHAM STINSON
Project Contact: 7027174th ST SW
EDMONDS, WA 98026
RECEIVED
Mar 03-2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
t: 206 228 0740
e: gstinson@gmaiL.com
6'
403ORS 403ORS 403ORS O
egress egress egress
open area 6ft� open area Eft= open area Eft=
sill height 42.5" sill height 42.5" sill height 42.5"
move window here
post to ceiling
Master Bedroom Walk-in Bedroom
Closet m � W ^�
8'wall, O �'yA
open @ top .„
to cathedral N
ceiling
SD SD
5'
O O
3068 2868 2868 B
interior bearing wall 674"
(supports roof only) CO O
2868
O
�
SD
N o N A
�a w O
S 7 N O
s�
1'11" Bedroom N cb
�N
Master Bath
O SD
abov �y
i
new construction
❑ load bearing wall
2ND (TOP) FLOOR PLAN -
PROPOSED
16'3"
7027 174th St SW
Bedroom Area renovation
March 2021
fir header
:ud
ALARMS/DETECTORS SHALL BE INSTALLED IN ■
=EPING ROOMS, IN THE AREA OUTSIDE THE
VG ROOM AND IN OTHER LOCATIONS PER IRC
NFPA 72. POWER SOURCE AND
ONNECTION PER CODE. ALARMS MUST BE A
M OF 36 INCHES AWAY FROM BATHROOM DOORS,
G OR COOLING REGISTERS, AND CEILING FANS. ■
)ubled 2x10 fir header
)ubled jack stud
New bedroom does not show how it is heated.
Interior spaces intended for human occupancy shall be
provided with active or passive space heating systems ■
capable of maintaining an indoor temperature of not
less than 680F (20°C) at a point 3 feet (914 mm) above i
the floor on the design heating day. I
Per 2018 IBC 1203.1 ■
d 2x8 fir header
jack stud
r ■ ■ ■ ■ ■
I if area is vaulted
r move to location ■
I closer to bedrooms
■
i ■ ■ ■ ■ Elm
Property Owner/ D. GRAHAM STINSON
Project Contact: 7027 174th ST SW
EDMONDS, WA 98026
RECEIVED
Mar 03-2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
t: 206 228 0740
e: gstinson@gmail.com