Loading...
APPROVED BLD-BLD2021-0319+Architectural_Plan+3.3.2021_1.28.01_PM+20739667'3" 403ORS 403ORS 403ORS remove window not load bearing joist direction Master Bedroom doubled 2x8 fir joists 16" o.c. interior bearing wall (supports roof only) Walk-in Closet r10 3068 coo not load bearing 'S 0 joist direction doubled 2x8 fir joists 16" o.c. Master Bath Bedroom O SD above ■ to remove 2ND (TOP) FLOOR PLAt 7027 174th St SW EXISTING Bedroom Area renovation March 2021 GARAGE BELOW 100% fire separation drywall coverage (GARAGE SEPARATION REQUIRES'/2" ■ ■GYPSUM WALL BOARD ON THE GARAGE (SIDE. 5/8" TYPE "X" GYPSUM WALL BOARD IS .REQUIRED WHERE THERE IS LIVING SPACE I (ABOVE. SUPPORTING COLUMNS, WALLS ■ ■AND BEAMS USE'/2" GYPSUM WALL BOARD I �I RC R302.6 ■ APPROVED PLANS MUST BE ON JOB SITE City of Edmonds Building Department APPROVED Plans ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE City Of Edmonds Building Department Work REMODEL Address 7027 174TH ST SW ---------------------------------------- Owner STINSON -------------------------------------------- Approved Date 3/11 /202' Building Official 4661p/� 1510oxh; Permit Number BLD2021-0319 Property Owner/ D. GRAHAM STINSON Project Contact: 7027174th ST SW EDMONDS, WA 98026 RECEIVED Mar 03-2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT t: 206 228 0740 e: gstinson@gmaiL.com 6' 403ORS 403ORS 403ORS O egress egress egress open area 6ft� open area Eft= open area Eft= sill height 42.5" sill height 42.5" sill height 42.5" move window here post to ceiling Master Bedroom Walk-in Bedroom Closet m � W ^� 8'wall, O �'yA open @ top .„ to cathedral N ceiling SD SD 5' O O 3068 2868 2868 B interior bearing wall 674" (supports roof only) CO O 2868 O � SD N o N A �a w O S 7 N O s� 1'11" Bedroom N cb �N Master Bath O SD abov �y i new construction ❑ load bearing wall 2ND (TOP) FLOOR PLAN - PROPOSED 16'3" 7027 174th St SW Bedroom Area renovation March 2021 fir header :ud ALARMS/DETECTORS SHALL BE INSTALLED IN ■ =EPING ROOMS, IN THE AREA OUTSIDE THE VG ROOM AND IN OTHER LOCATIONS PER IRC NFPA 72. POWER SOURCE AND ONNECTION PER CODE. ALARMS MUST BE A M OF 36 INCHES AWAY FROM BATHROOM DOORS, G OR COOLING REGISTERS, AND CEILING FANS. ■ )ubled 2x10 fir header )ubled jack stud New bedroom does not show how it is heated. Interior spaces intended for human occupancy shall be provided with active or passive space heating systems ■ capable of maintaining an indoor temperature of not less than 680F (20°C) at a point 3 feet (914 mm) above i the floor on the design heating day. I Per 2018 IBC 1203.1 ■ d 2x8 fir header jack stud r ■ ■ ■ ■ ■ I if area is vaulted r move to location ■ I closer to bedrooms ■ i ■ ■ ■ ■ Elm Property Owner/ D. GRAHAM STINSON Project Contact: 7027 174th ST SW EDMONDS, WA 98026 RECEIVED Mar 03-2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT t: 206 228 0740 e: gstinson@gmail.com