BLD2020-0559+Architectural_Plan+6.1.2020_4.04.34_PMGENERAL NOTES GENERAL REQUIREMENTS ALL WORK SHALL COMPLY WITH THE 2015 EDITION OF THE INTERNATIONAL BUILDING CODE (STRUCTURAL DESIGN), INTERNATIONAL RESIDENTIAL CODE (ORDINANCE), MOST RECENT EDITION OF THE UNIFORM PLUMBING CODE, INTERNATIONAL MECHANICAL CODE, NATIONAL ELECTRIC CODE, WASHINGTON STATE ENERGY CODE, ANY STATE AND LOCAL AMENDMENTS. AND ANY APPLICABLE LAND USE CODE. THE OWNER/BUILDER SHALL BE RESPONSIBLE FOR DEVELOPING CONSTRUCTION DETAILS NECESSARY TO CONSTRUCT A WEATHER TIGHT, DURABLE BUILDING. ALL FLASHING, WEATHERPROOFING, ROOFING AND WATERPROOFING DETAILS AND CONSTRUCTION OF THESE DETAIL ASSEMBLIES ARE THE FULL AND COMPLETE RESPONSIBILITY OF THE OWNER/BUILDER AND THESE DETAILS SHALL BE CONSTRUCTED PER MANUFACTURER REQUIREMENTS, BUILDING CODE REQUIREMENTS AND ACCEPTED INDUSTRY STANDARDS FOR PERFORMANCE. THE DESIGNER HAS NOT BEEN CONTRACTED TO PERFORM CONSTRUCTION ADMINISTRATION SERVICES OR CONSTRUCTION OBSERVATION SERVICES FOR THIS PROJECT AND IS NOT LIABLE OR RESPONSIBLE FOR DETERMINING ADEQUACY OF CONSTRUCTION OF BUILDING ENVELOPE OR DETAILS. THE OWNER/BUILDER SHALL BE RESPONSIBLE FOR INSPECTING AND VERIFYING THAT ALL FLASHING, WEATHERPROOFING, ROOFING AND WATERPROOFING DETAILS ARE BUILT CORRECTLY AND MEET OWNER/BUILDER'S APPROVAL BEFORE BEING COVERED BY SUBSEQUENT CONSTRUCTION WORK. USE OF THESE PLANS BY ANYONE OTHER THAN THE INTENDED OWNER/BUILDER IS NOT PERMITTED. ANY REDUNDANCY BETWEEN THESE NOTES AND S-SHEETS THE S-SHEETS SHALL SUPERSEDE. SITE WORK 1. BACKFILL FOUNDATION DRAIN AT PERIMETER OF BUILDING WITH COURSE GRANULAR FILL. (1 1/2-3/8 CLEAN WASHED ROCK WITH MIN. 12" WIDE BLANKET EXTENDING TO FINISHED GRADE.) PROTECT DRAIN TILE AND WATERPROOFING. 2. ROUGH GRADING SHALL PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING. TRENCH TO ELEVATIONS BELOW FROST LINE FOR STORM DRAINS, WATER LINES, SEWERS, AND IRRIGATION SLEEVES. 3. PROVIDE PERFORATED PLASTIC PIPE FOUNDATION DRAINS WHERE SHOWN IN DRAWINGS. CONNECT TO ROOF AND STORM WATER SYSTEM. IN JURISDICTIONS REQUIRING SEPARATE ROOF DRAIN LINES, PROVIDE TIGHT LINE CONNECTED TO ROOF DRAINS IN ADDITION TO PERFORATED DRAIN LINES. 4. ROCKERIES AND RETAINING WALLS SHALL BE DESIGNED BY A LICENSED ENGINEER AND INSTALLED PER APPLICABLE CODE. MECHANICAL 1. PLUMBING SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT, EXPERIENCED PLUMBER AND IN ACCORDANCE WITH THE UNIFORM PLUMBING CODE AND LOCAL CODES. 2. HVAC SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT AND EXPERIENCED MECHANICAL CONTRACTOR IN ACCORDANCE WITH THE INTERNATIONAL MECHANICAL CODE, 2015 IRC, AND LOCAL CODES. PROVIDE DOCUMENTATION OF FURNACE A.F.U.E. DUCTWORK INSULATION SHALL CONFORM TO THE WASHINGTON STATE ENERGY CODE. WHEN INSTALLED IN GARAGE, HEATING UNITS SHALL BE PLACED SUCH THAT ALL PILOT LIGHTS, BURNERS, HEATING ELEMENTS, OR SWITCHES ARE LOCATED A MIN. OF 18" ABOVE THE GARAGE FLOOR. THERMAL AND MOISTURE 1. INSULATION REQUIREMENTS SHALL MEET OR EXCEED THE LATEST EDITION OF THE WASHINGTON ENERGY CODE OR ENERGY CODE ADOPTED BY THE LOCAL JURISDICTION. INSULATION REQUIREMENTS SHALL BE SHOWN ON PLANS OR ON A SEPARATE ENERGY CALCULATION SHEET. 2. APPLY 1 COAT (MIN) HEAVY BODIED ASPHALT BITUMINOUS DAMPPROFING TO EXTERIOR OF FOUNDATION WALLS, FROM FOOTING TO FINISHED GRADE AT FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE INTERIOR SPACES AND FLOORS BELOW GRADE.. (R406.1) 3. APPLY APPROPRIATE WATER REPELLENTS TO ANY MASONRY, CEMENT, PLASTER, OR STUCCO PER MANUFACTURER'S INSTRUCTIONS. 4. PROVIDE 6 MIL BLACK POLYETHYLENE VAPOR BARRIER IN ALL CRAWLSPACE AREAS, LAPPED AT ALL SPLICES AND OVER FOOTINGS. FINISHES GARAGE CEILINGS BENEATH HABITABLE SPACES SHALL BE COVERED WITH 5/81, TYPE "X" GYPSUM WALL BOARD. GARAGE CEILINGS BENEATH ATTIC OR NON LIVING SPACE SHALL BE COVER WITH 5/81' GYPSUM WALL BOARD. WALLS AND STRUCTURE SEPARATING RESIDENTIAL AND GARAGE SPACES SHALL BE COVERED WITH 1/2" GYPSUM WALL BOARD. ALL GARAGE GYPSUM WALLBOARD SHALL HAVE JOINTS FIRETAPED WITH NAILS SET AND COMPOUNDED. ALL OTHER WALLS SHALL RECEIVE 1/2" GYPSUM WALLBOARD. CEILINGS WITH JOISTS/ TRUSS SPACES GREATER THAN 16" SHALL RECEIVE 5/8" GYPSUM WALLBOARD OR 1/2" GYPSUM CEILING BOARD. WALLS SURROUNDING TUBS OR SHOWERS SHALL BE COVERED WITH WATER-RESISTANT GYPSUM WALL BOARD. WATER- PROOF SURFACE TO A HEIGHT OF 72" ABOVE ADJACENT FLOOR. ANY CEMENT PLASTER OR STUCCO SHALL BE INSTALLED IN ACCORDANCE WITH NORTHWEST WALL AND CEILING BUREAU RECOMMENDATIONS FOR MATERIALS, BACKING, LATH, APPLICATION TECHNIQUES, AND FINISHES. ELECTRICAL SYSTEMS SHALL BE DESIGNED AND INSTALLED BY A COMPETENT AND EXPERIENCED ELECTRICAL CONTRACTOR IN ACCORDANCE WITH MOST CURENT STATE AND LOCAL ELECTRICAL CODE. ELECTRICAL SCHEMATICS PROVIDED IN THIS SET OF PLANS ARE FOR REFERENCE LAYOUT ONLY. FIRESTOPPING FIRESTOPPING SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND HORIZONTAL) AND TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY AND THE ROOF SPACE. FIRESTOPPING SHALL BE PROVIDED IN WOOD FRAME CONSTRUCTION IN THE FOLLOWING LOCATIONS: 1. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES NOT TO EXCEED 10'-0" HORIZONTALLY, AND AT THE CEILING AND FLOOR LEVEL. 2. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS, COVE CEILINGS, ETC. 3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN AND WALL CAVITIES IN LINE WITH STRINGERS. 4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS AND FIREPLACES AT CEILING AND FLOOR LEVEL, WITH NON-COMBUSTABLE MATERIALS. MISCELLANEOUS 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CONDITIONS, ETC. IN THE FIELD PRIOR TO PROCEEDING. 2. VERIFY SIZE AND LOCATION OF ALL OPENINGS IN THE FLOOR, ROOF, AND WALL WITH MECHANICAL AND ELECTRICAL WORK. 3. PROVIDE SMOKE DETECTORS IN ACCORDANCE WITH (R314) SMOKE DETECTORS TO BE HARD WIRED AND INTERCONNECTED. (R314.4, R314.5). A SMOKE DETECTOR SHALL BE INSTALLED IN EACH SLEEPING ROOM AND OUTSIDE EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. (R314) CARBON MONOXIDE ALARMS SHALL BE INSTALLED OUTSIDE EACH SEPARATE SLEEPING AREA AND IN THE VICINITY OF THE BEDROOMS. (R315) 4. KITCHEN RANGE, DRYER, BATH AND LAUNDRY ROOM VENTILATION DUCTS SHALL TERMINATE OUTSIDE THE BUILDING AND BE EQUIPPED WITH BACK DRAFT DAMPERS. 5. EXTERIOR OPENINGS TO THE WEATHER SHALL BE FLASHED AND COUNTER -FLASHED IN SUCH A MANNER AS TO MAKE THEM WATERPROOF. ROOF FLASHING PER R903. 6. GUARDRAILS TO BE A MIN. OF 36" ABOVE FINISH FLOOR. (R312) (EXCEPTIONS TO COMMERCIAL PER I.B.C.) 7. OPEN GUARDRAILS TO HAVE INTERMEDIATE RAILS OR PICKETS PLACED SUCH THAT A SPHERE 4" IN DIAMETER CANNOT PASS THROUGH. 8. BEDROOM EMERGENCY EGRESS WINDOWS MUST HAVE A MIN. NET CLEAR OPENING OF 5.7 SQ. FT. MINIMUM NET CLEAR OPENABLE WIDTH OF 20" AND MIN. NET CLEAR OPENING HEIGHT OF 24". MAX. FINISHED HEIGHT OF 44" FROM FINISHED FLOOR TO BOTTOM OF CLEAR OPENING (R310.1). AREA CALCULATIONS HEATED AREAS SQUARE FOOTAGE EXISTING MAIN FLOOR 1217 NEW ADDITION 270 TOTAL 1487 NON -HEATED AREAS SQUARE FOOTAGE NEW DECK 120 DRAWING INDEX SHEET NO. I DESCRIPTION Al COVER SHEET, INDEX, GENERAL NOTES A2 ELEVATIONS A3 MAIN FLOOR PLAN S1 STRUCTURAL NOTES/SCHEDULES S2 BUILDING CROSS SECTION, SHEARWALL & HOLDOWN LOCATIONS S3 FOUNDATION PLAN S4 FRAMING AND ROOF PLAN SYMBOL LEGEND CARBON MONOXIDE DETECTOR OO INTERCONNECTED 110v w/ BATTERY C.O. BACKUP O SMOKE DETECTOR S.D. INTERCONNECTED 110v w/ BATTERY O EXHAUST FAN (VENT TO OKEYNOT 101) DOOR SCHEDULE 1i WINDOW SCHEDULE REVISION- SEE DESCRIPTION IN l SIMN. DETAIL 101 SIMILAR DETAIL DETAIL SHEET 1 SIM BUILDING CROSS A10 DETAIL SHEET Room name ROOM Know what's b@IOW. STATE LAW REQUIRES THAT YOU CALL BEFORE YOU DIG TO Call before you dig. LOCATE ALL UNDERGROUND UTILITIES. BARTH ADDITION 8409 216TH STREET S.W., EDOMONDS., WA 98026 2015 WASHINGTON STATE ENERGY CODE R301 CLIMATE ZONE THIS PLAN IS DESIGNED FOR CLIMATE ZONE 5 AND MARINE 4 PER TABLE R301.1, 2015 WASHINGTON STATE ENGERY CODE. R101.4.3 Additions, alterations, renovations or repairs. Additions, alterations, renovations or repairs to an existing building, building system or portion thereof shall conform to the provisions of this code as they relate to new construction without requiring the unaltered portion(s) of the existing building or building system to comply with this code. Additions, alterations, renovations or repairs shall not create an unsafe or hazardous condition or overload existing building systems. An addition shall be deemed to comply with this code if the addition alone complies or if the existing building and addition comply with this code as a single building. Exception: The following need not comply provided the energy use of the building is not increased: 1. Storm windows installed over existing fenestration. 2. Glass only replacements in an existing sash and frame. 3. Existing ceiling, wall or floor cavities exposed during construction provided that these cavities are filled with insulation. 2x4 framed walls shall be insulated to a minimum of R-15 and 2x6 framed walls shall be insulated to a minimum of R-21. 4. Construction where the existingroof, wall or floor cavity is not exposed. � Y p 5. Reroofingfor roofs where neither the sheathing nor the insulation is exposed. Roofs without insulation in the cavity and where the sheathing or 9 P Y 9 insulation is exposed during reroofing shall be insulated either above or below the sheathing. Replacement of existing doors that separate conditioned space from the exterior shall not require the installation of a vestibule or revolving door, provided, however, that an existing vestibule that separates a conditioned space from the exterior shall not be removed. 7. Alterations that replace less than 60 percent of the luminaires in a space, provided that such alterations do not increase the installed interior lighting power. 8. Alterations that replace only the bulb and ballast within the existing luminaires in a space provided that the alteration does not increase the installed interior lighting power. The building official may approve designs of alterations or repairs which do not fully conform with all of the requirements of this code where in the opinion of the building official full compliance is physically impossible and/or economically impractical and: 1. The alteration or repair improves the energy efficiency of the building; or 2. The alteration or repair is energy efficient and is necessary for the health, safety, and welfare of the general public. TABLE R402.1.1 Climate Zone Fenestration U-Factor" Skylight U-Factor Glazed Fenestration SHGC''` Ceiling Wood Frame Wall" Mass Wall R-Value' Floor Below Grade Wall `' Slab' R-Value & Depth 5 & Marine 4 R-Valuea U-Factor" 6 R-Valuea U-Factora n/a 0.30 n/a 0.30 n/a 0.50 n/a 0.50 n/a n/a n/a n/a 49' 0.026 49 0.026 21 int 0.056 21+5ci 0.044 21/21'' 0.056 21+5' 0.044 30' 0.029 30" 0.029 10/15/21 int + TB 0.042 10/15/21 int + TB 0.042 10, 2 ft n/a 10, 4 ft n/a R402.2 FENESTRATION (PRESCRIPTIVE R402.3 Fenestration (Prescriptive). In addition to the requirements of Section R402, fenestration shall comply with Sections R402.3.1 through R402.3.6. R402.3.1 U-factor. An area -weighted average of fenestration products shall be permitted to satisfy the U-factor requirements. R402.3.2 Glazed fenestration SHGC. An area -weighted average of fenestration products more than 50 percent glazed shall be permitted to satisfy the SHGC requirements. R402.3.3 Glazed fenestration exemption. Up to 15 square feet (1.4 m2) of glazed fenestration per dwelling unit shall be permitted to be exempt from U-factor and SHGC requirements in Section R402.1.1. This exemption shall not apply to the U-factor alternative approach in Section R402.1.3 and the total UA alternative in Section R402.1.4. R402.3.4 Opaque door exemption. One side -hinged opaque door assembly up to 24 square feet (2.22 m2) in area is exempted from the U-factor requirement in Section R402.1.1. This exemption shall not apply to the U-factor alternative approach in Section R402.1.3 and the total UA alternative in Section R402.1.4 R404.1 LIGHTING EFFICACY MIN. OF 75%OF LAMPS IN PERMANENTLY INSTALLED FIXTURES SHALL BE HIGH EFFICACY LAMPS WHERE NEW CONSTRUCTION OCCURS. NOTE: SEE SHEETS S2 FOR INSULATION LOCATIONS AND MISC. DETAILS. ENERGY CREDIT THIS ADDITION REQUIRES 0.5 CREDITS PER 406.2. OPTION 5A. EFFICIENT WATER HEATING 5a: 0 All showerhead and kitchen sink faucets installed in the house shall be rated at 1.75 GPI\l or less. All other lavatory faucets shall be rated at 1.0 GPM or less.` To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall specify the nialinnun flow rates for all showerheads, kitchen sink- faucets. and other lavatory faucets. M1507.3.1 SYSTEM DESIGN. EACH DWELLING UNIT OR GUESTROOM SHALL BE EQUIPPED WITH A VENTILATION SYSTEM COMPLYING WITH SECTION M1507.3.4, M1507.3.5, M1507.3.6 OR M1507.3.7. COMPLIANCE IS ALSO PERMITTED TO BE DEMONSTRATED THROUGH COMPLIANCE WITH THE INTERNATIONAL MECHANICAL CODE. M1507.3.2 CONTROL AND OPERATION. 1. LOCATION OF CONTROLS. CONTROLS FOR ALL VENTILATION SYSTEMS SHALL BE READILY ACCESSIBLE BY THE OCCUPANT. 2. INSTRUCTIONS. OPERATING INSTRUCTIONS FOR WHOLE -HOUSE VENTILATION SYSTEMS SHALL BE PROVIDED TO THE OCCUPANT BY THE INSTALLER OF THE SYSTEM. 3. LOCAL EXHAUST SYSTEMS. LOCAL EXHAUST SYSTEMS SHALL BE CONTROLLED BY MANUAL SWITCHES, DEHUMIDISTATS, TIMERS, OR OTHER APPROVED MEANS. M1507.3.4.4 OUTDOOR AIR INLETS. OUTDOOR AIR SHALL BE DISTRIBUTED TO EACH HABITABLE SPACE BY INDIVIDUAL OUTDOOR AIR INLETS. WHERE OUTDOOR AIR SUPPLIES ARE SEPARATED FROM EXHAUST POINTS BY DOORS, PROVISIONS SHALL BE MADE TO ENSURE AIR FLOW BY INSTALLATION OF DISTRIBUTION DUCTS, UNDERCUTTING DOORS, INSTALLATION OF GRILLES, TRANSOMS, OR SIMILAR MEANS. DOORS SHALL BE UNDERCUT TO A MINIMUM OF 1/2 INCH ABOVE THE SURFACE OF THE FINISH FLOOR COVERING. INDIVIDUAL ROOM OUTDOOR AIR INLETS SHALL: 1. HAVE CONTROLLABLE AND SECURE OPENINGS; 2. BE SLEEVED OR OTHERWISE DESIGNED SO AS NOT TO COMPROMISE THE THERMAL PROPERTIES OF THE WALL OR WINDOW IN WHICH THEY ARE PLACED; 3. PROVIDE NOT LESS THAN 4 SQUARE INCHES OF NET FREE AREA OF OPENING FOR EACH HABITABLE SPACE. ANY INLET OR COMBINATION OF INLETS WHICH PROVIDE 10 CFM AT 10 PASCALS ARE DEEMED EQUIVALENT TO 4 SQUARE INCHES NET FREE AREA. INLETS SHALL BE SCREENED OR OTHERWISE PROTECTED FROM ENTRY BY LEAVES OR OTHER MATERIAL. OUTDOOR AIR INLETS SHALL BE LOCATED SO AS NOT TO TAKE AIR FROM THE FOLLOWING AREAS: 1. CLOSER THAN 10 FEET FROM AN APPLIANCE VENT OUTLET, UNLESS SUCH VENT OUTLET IS 3 FEET ABOVE THE OUTDOOR AIR INLET. 2. WHERE IT WILL PICK UP OBJECTIONABLE ODORS, FUMES OR FLAMMABLE VAPORS. 3. A HAZARDOUS OR UNSANITARY LOCATION. 4. A ROOM OR SPACE HAVING ANY FUEL -BURNING APPLIANCES THEREIN. 5. CLOSER THAN 10 FEET FROM A VENT OPENING OF A PLUMBING DRAINAGE SYSTEM UNLESS THE VENT OPENING IS AT LEAST 3 FEET ABOVE THE AIR INLET. 6. ATTIC, CRAWL SPACES, OR GARAGES. U Z N 00 M Z Q a �0 J W d m W N GS J J Lo U �Co C) O `E Z W O . uJ N m o aa) w m p W a E O U C + _ �y n r � O u ii1 C Q) L ir 11 Z N-O 0 y @ L° d d. O Z O� O N O C° L NaJ ° s~° o m �' m ?.E o o@ Taiy°Dc@ o�st io yo aE naiO w�o�d-NE o WoU N O O Li F Z o. o @ o f E 1-O CV 0 (DO CT Q Zcn 0 0 z 0 O LU Q W U Z W LL N C� LULU CV CIOm O Q � cu cu 0 0 0 Z PROJECT NO. 200506 DESIGNED BY TL DRAWN BY TL & RIM CHECKED BY TL SHEET NO. Al PRINT DATE 5/31/2020 6:51:14 AM ELEVATION NOTES PROVIDE METAL FLASHING OVER TOPS OF WINDOWS AND TOPS OF TRIMS DIRECTLY EXPOSED TO WEATHER. ROOFING MATERIAL, SIDING AND FLASHING SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS, INDUSTRY STANDARDS AND PER I.R.C. PORCHES, BALCONIES, RAMPS OR RAISED SURFACES LOCATED MORE THAN 30" ABOVE THE FLOOR OR GRADE BELOW SHALL HAVE GUARDS NOT LESS THAN 36" IN HEIGHT. OPEN SIDE OF STAIRS WITH A TOTAL RISE OF MORE THAN 30" SHALL HAVE GUARDS NOT LESS THAN 34" IN HEIGHT MEASURED VERTICALLY FROM THE NOSING OF THE TREADS. INTERMEDIATE RAILS OR ORNAMENTAL CLOSURES SHALL BE SPACED SUCH THAT A 4" SPHERE CANNOT PASS THROUGH. THE TRIANGLE OPENINGS FORMED BY THE RISER, TREAD, AND BOTTOM OF RAIL SHALL BE SUCH THAT A 6" SPHERE CANNOT PASS THROUGH. EXTERIOR STAIRS SHALL BE NOT LESS THAN 36" WIDE. HANDRAILS SHALL NOT PROJECT MORE THAN 4.5" ON EITHER SIDE OF THE STAIRWAY AND MIN. CLEAR WIDTH AT OR BELOW THE HANDRAIL SHALL NOT BE LESS THAN 31.5". MAX. RISER HEIGHT IS 7 3/4". MIN. TREAD DEPTH SHALL BE 10". A LANDING IS REQUIRED AT TOP AND BOTTOM OF EACH STAIRWAY. SITE ADDRESS SHALL BE VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. NUMBERS SHALL CONTRAST WITH BACKGROUND, BE ARABIC NUMBERS OR ALPHABETICAL LETTERS, BE A MIN. OF 4" IN HEIGHT WITH A MIN. STROKE WIDTH OF 1/2". (R319.1) Z. building height - 9 1/4" Ridge_Heiaht 113'-2 MAIN F 9' -1 MAIN F �J 101' - 1 rk agE 98er 9 1 /4" 2 EGRESS Ridge Hei ht 113' - 2 1 /2" MAIN FLOOR PLATE 109' - 1 3/8" MAIN FLOOR — — — 101' - 1 3/8" J -average grade AH jaF E�u 1E9 E� - jaE E�L E� a�E 98' - 9 1/4" CRAWLSPACE ACCESS (EITHER FROM EXISTING CRAWLSPACE OR THROUGH 3) EAST ELEVATION NEW WALL ACCESS MIN. NORTH ELEVATION 1/4" = 1'-0" - - ROOFING TO MATCH EXISTING. - --- NOTE: VERIFY EXISTING ROOF PITCH PRIOR TO CONSTRUCTION. Ridge Height 113'-21/2" - MAIN FLOOR PLATE -- CONT. ALUM. i 109' -1 3/8" z ® TRIMS AND SIDING TO MATCH EXISTINGii ❑ CDw PER OWNER SPECS. 00 3 w 10MAIN FLOOR 1' - 1 3/8" 98er9 1/4rade n WEST ELEVATION 1/4" = 1'-0" U Z N 00 o W Z a E a �0 , Lu wa-8 � �a O J, U �m� M CO Z W N C W o W m O W a 2 F E U C + C C O I� }'� o Z O J U C r N O L z o Q$, '= - 10 C E N O W U£ O U Co U EO p C C 3 -N N O U J J- y U a 0 U H C {p y a •- - 0 N O O. ( LU Z ao � � ID E n d 1-0 CN O (DO CT Q zcn I) 0 Z O 0 LU W U z W LL LU W� NO CV m O Q � m 00 0 _ 0 .n 6 z PROJECT NO. 200506 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. A2 PRINT DATE 5/31/2020 6:54:15 AM DOOR SCHEDULE SYM. NO. WIDTH HEIGHT DOOR TYPE COMMENTS MAIN FLOOR D1 2'- 6" 6'-8" SINGLE PANEL D3 2' -10" 6' - 8" SINGLE POCKET D7 3' - 0" 6' - 8" BI-FOLD 2 PANEL CLOSET DOOR D8 5' - 0" 6' - 8" BI-FOLD 4 PANEL CLOSET DOOR D10 6' - 0" 6' -10" SLIDING GLASS PATIO (TEMP.) WINDOW SCHEDULE SYM. NO. WIDTH HEIGHT AREA WINDOW TYPE U-VALUE COMMENTS MAIN FLOOR 3 6'- 0" 3' - 6" 21 SF SLIDER 0.30 5 6'- 0" 5' - 0" 30 SF SLIDER 0.30 TEMP. GLASS 6 6'- 0" 3' - 6" 21 SF SLIDER 0.30 Grand total 72 SF KEY VALUE KEYNOTE SCHELDULE TEXT 08 EGRESS WINDOWS: OPENINGS ARE REQUIRED FOR ALL SLEEPING ROOMS AND BASEMENTS. BOTTOM OF CLEAR OPENING IS NOT TO EXCEED 44" ABOVE FLOOR. OPENABLE AREA IS 5.7 SQ. FT. NET CLEAR MIN. EXCEPT 5.0 SQ. FT. IS ALLOWED FOR AN OPENING WITHIN 44" OF FINISHED GRADE. (R310.1) 11 TYPICAL EXTERIOR WALL: SIDING o/ INFILTRATION BARRIER o/ EXTERIOR SHEATHING PER STRUCTURAL PLANS o/ 2X6 STUDS @ 16" O.C. w/ R-21 BATT INSULATION AND 1/2" MIN. GWB AT INSIDE FACE w/ P.V.A. PRIMER. 17 CLOSET ROD w/ VINYL COATED WIRE SHELF MAIN FLOOR 1/4" = 1'-0" WALLS INDICATE NG STRUCTURE. U z N O O 00 z QE a �0 wa•�, -a U J� @ co CO 2 z W 04 C W �2 .Fu oW W m o W a F + -= E O + ALA'' W Z o Z J p U CO C O L (0 N N O N d N a m L H O- T j L U E y y C O J O y 0) C 0 0- @ t6 O (0 .t.. N U lL0Q o. '= C N O L 10C ELU N pWgV$oc�coUpp 3 �m�' UJJ- 2 U a0U a0•- -p N O H C {p y O. (6 Z a o m o E d 1-O CN O (DO CT Q z cn I) Z O Lu Q W U z W LL Lu 0 W� CV � O Q � m 00 0 _ 0 Mn 6 Z PROJECT NO. 200506 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY TL SHEET NO. A3 PRINT DATE 5/31/2020 6:54:35 AM GENERAL NOTES All design and construction shall conform to the requirements of the International Building Code 2015 Edition. Contractor shall verify all levels, dimensions and existing conditions in field before proceeding with any construction or demolition. Contractor shall notify the Architect of any discrepancies or field changes Contractor shall be responsible for all safety precautions and the methods, techniques, sequences or procedures required to perform the work. Contractor shall provide adequate shoring and bracing of all structural members, existing construction and soil excavations as required, in a manner suitable to the work sequence. Temporary shoring and bracing shall not be removed until all final connections have been completed in accordance with the drawings and materials have achieved design strength. Foundations walls greater than 4 feet shall not be backfilled until the floor framing and all connections to the floor framing per these details are complete. CHANGES: No changes to these structural drawings are permitted without written consent of the Engineer. Changes will be billed to the client, owner or contractor at the Engineer's hourly rate. Design drawings and calculations, for pre -manufactured wood trusses and joists shall bear the seal and signature of the Washington State Registered Professional Engineer who is responsible for the design, and shall be submitted to the Architect and Building official for review prior to fabrication. DESIGN LOADS LIVE LOADS: Live loads are determined in accordance with ASCE Ch. 7 L = 40 PSF (Residential) SNOW LOADS: Snow loads are determined in accordance with ASCE Ch. 7 with the following Factors: Ground Snow Load Pg = 20 psf Ct = 1.0 Ce = 1.0 Roof Snow Load Ps = 25 psf Is = 1.0 WIND LOADS: Wind loads are based on ASCE 7-10 Ch. 28 (Envelope Procedure) with the following factors: Exposure Category = B Iw = 1.0 Velocity (3 sec) =110 mph (ult) Kzt = 1.0 Design wind pressured for determining forces on components and cladding are determined in accordance with ASCE 7-10 Chapter 30. SEISMIC LOADS: Seismic loads are based on the Equivalent Lateral Force Procedure in ASCE 7-10 Section 12.8 with the following factors: Risk Category = II Ss = 1.27 Site Class = D S1 = 0.496 Design Category = D SIDS = 0.847 R = 6.5 (wood shear wall) SD1 = 0.497 Ie = 1.0 Cs = 0.130 (ult.) FOUNDATIONS Concrete foundations shall bear on stiff, competent, undisturbed native soil. Prior to construction, the contractor shall obtain confirmation from the Building Official that the native soil at this project is adequate to support the following bearing pressure: Allowable bearing pressure used for structural design = 2000 psf (assumed) Where footings must bear on structural fill due to inadequate soil conditions, the fill shall be mixed and compacted in accordance with specifications provided by a Geotechnical Engineer licensed in the State of Washington. Bottom of footing elevation shall be located at minimum frost depth 18" below top of finished grade unless required otherwise by the Building Official. The contractor shall confirm the minimum frost depth with the Building Official prior to excavation. CONCRETE Concrete work shall comply, in general, with ACI 301 (latest edition) "Specifications for Structural Concrete for Buildings." CONCRETE MIXES: Concrete mixes shall conform ACI 318 Ch. 5. Minimum concrete strength f'c at 28 days shall be as follows: Slab -on -grade, Curbs and Pads - 2000 psi Footings - 2500 psi Walls, Stems - 3000 psi (2500 psi used for structural design) Water/cement ratio shall be measured by weight and shall be based on the total cementitious material. Water/cement ratio shall be determined by the supplier based on strength requirements and shall not exceed 0.55. Water -reducing admixtures may be incorporated in concrete mix designs but shall conform to ASTM C 464, and be used in accordance with the manufacturer's recommendations. CaCI and other water-soluable chloride admixtures shall not be used. REINFORCING STEEL: All reinforcing shall be deformed bar (rebar) with bar diameters specified in these drawings and properties below: All reinforcing unless noted otherwise - ASTM A615, Grade 60 #3 stirrups and ties - ASTM A615, Grade 40 Welded rebar - ASTM A706, Grade 60 Galvanized Welded Wire Fabric - ASTM A165 Reinforcing steel shall be detailed in accordance with ACI 315 "Manual of Standard Practice for Detailing Reinforced Concrete Structures." Reinforcing steel shall be lapped as noted on the drawings. Where lap length is not shown, reinforcing bars shall be lapped as follows: #5 and smaller - 48 bar diameters #6 and larger - 60 bar diameters Minimum concrete cover over reinforcing shall be as follows: Nonstructural Slab -on -grade - Mid -Depth Wall Bars: interior face - 3/4" exposed to earth/weather - 1-1/2" (#5 and smaller) 2" (#6 and larger) Footings: Bottom Bars - 3" (cast against earth) Top Bars - 1-1/2" Side Bars - 2" Provide supports as required for proper alignment and concrete cover around the reinforcement. Consult the CRSI Manual of Standard Practice MSP-1 for specific information. WOOD SAWN LUMBER: Structural sawn lumber shall be kiln dried and be of the species and grade noted below or better: Use Grade Fb(psi) Wall Studs Stud 675 Plates & Planks Hem Fir #2 850 Joists & Rafters Hem Fir #2 850 4x Beams Douglas Fir -Larch #2 900 6x Beams Douglas Fir -Larch #2 875 Posts Douglas Fir -Larch #2 750 2x4 T&G Decking Douglas Fir -Larch Select 1750 All lumber and plywood in contact with concrete, stucco, masonry or other cementitious materials shall be treated with an E.P.A. acceptable wood preservative, such as Alkaline -Copper -Quaternary "ACQ" or Copper Azole "CBA" type A and B. All wood connectors shall be manufactured by Simpson Strong Tie Company (or approved equal), and of the size and type shown on the drawings. All wood connectors in contact with preservative -treated wood shall be Triple Zinc G-185 galvanized (1.85 oz/sq ft coating). MINIMUM WOOD NAILING REQUIREMENTS: Unless otherwise noted on the drawings, typical wood framing shall be fastened as follows. See IBC Table 2304.10.1 for fastener alternatives not shown. Location Min. Nail Quantity/Spacing Type* Beams (built up 2x's) 3" x 0.131" 24" o.c. T&B* FN EF* staggered Blocking -to joists, rafters, trusses 3" x 0.131" 2 each end TN or studs -to top plates 3" x 0.131" 3 TN Bottom plate -to joist, rim joist 3" x 0.131" 12" o.c. FN or blocking -to studs 3" x 0.131" 3 EN Header (built up 2x's) 16d box 12" o.c. T&B FN Header -to studs 3" x 0.131" 4 TN Joist -to supports 3" x 0.131" 3 TN -to rim joist 3" x 0.131" 4 EN Rafter -to supports 3" x 0.131" 4 TN, EN Rim Joist -to sill or blocking 3" x 0.131" 6" o.c. TN Stud -to Stud 3" x 0.131" 12" o.c. FN -to top/bottom plate 3" x 0.131" 4 TN Top plate -to top plate 3" x 0.131" 12" o.c. FN -to studs 3" x 0.131" 3 EN -laps at corners and 3" x 0.131" 3 FN intersections Truss to top plate 3" x 0.131" 4 TN *EN = end nail, FN = face nail, TN = toe nail, EF = "each face", T&B = "top and bottom" RATED SHEATHING: Wood structural panels shall bear the APA trademark of the American Plywood Association. Sheathing shall be as follows: Shear Wall Shtg 7/16" 32/16 C-D INT APA with Exterior Glue (CDX) Roof Shtg 15/32" 32/16 C-D INT APA with Exterior Glue (CDX) Sub Floor Shtg 3/4" 48/24 T&G C-D INT APA with Exterior Glue Sheathing shall be orientated over the supports as shown on the drawings. Shear wall sheathing shall be blocked at all panel edges as shown in the shear wall schedule. GLUED LAMINATED MEMBERS: Glued Laminated members shall each bear an AITC identification mark and be accompanied by an AITC certificate of conformance. One coat of end sealer shall be applied immediately after trimming either shop or field. Members shall be Visual Graded Western Species Inductrual, Architectural or Premium grade with strength as follows: Symbol Species Fb E GLB 24F-V4 DF/DF 2400/1850 psi 1,800,000 psi GLIB 24F-V8 DF/DF 2400/2400 psi 1,800,000 psi ENGINEERED COMPOSITE LUMBER: Engineered Composite Lumber shall be manufactured by Trus-Joist, Boise Cascade or approved equal and shall have the following minimum strength (based on 12" member depth): Symbol Fb E PSL 2900 psi 2,000,000 psi LVL 2600 psi 2,000,000 psi LSL 1700 psi 1,300,000 psi Versa -Lam (1Y4-2Y") 2800 psi 2,000,000 psi VersalLam (3%" & wider) 3100 psi 2,000,000 psi RECOMMENDED INSPECTIONS The following recommended minimum items shall be inspected by a qualified individual provided by the Building Official: -Footings bear on competent native soil per the "Foundations" section above -Footing reinforcement -Shear wall sill plate anchors and washers per schedule -Shear wall nailing and shear clips per schedule TYPICAL DETAILS In addition to the details and schedules on the framing plans, those noted as "Typical" shall be ised throughout the structure as applicable. STRUCTURAL NOTES LX UUN I A34 WITH SD# SCREWS EACH F ROOF RAFTER PEI. I 10 BEAM PER LAN RAFTERS TO RIDGE BEAM x Q 00 v TOP Pl. MAN WOOD FRAMING PER PLAN VARIES. SEE 20/S2 FOR ALL CONNECTIONS PT SILL PLATE w/ ANCHOR BOLTS AND WASHERS PER SHEAR WALL SCHEDULE. MINIMUM ANCHOR BOLT EMBEDMENT = 7". #4 HORIZ. AT 18" o.c. AND (2) AT TOP OF WALL #4 VERT. DOWELS AT 18" o.c. ALTERNATE HOOK AT BOTTOM FOOTING PER PLAN SINGLE REINFORCING NOTES: 1. VERTICAL REINFORCING NOT SHOWN FOR CLARITY 2. SEE STRUCTURAL NOTES FOR CLEAR COVER 24" #4 x 24" MATCH HORIZ REINF. 24" #4 x 24" MATCH HORIZ REINF. #4 x 24" MATCH HORIZ REINF. DOUBLE REINFORCING TYPICAL CONCRETE FOUNDATION 1 TYPICAL CONCRETE WALL AND FOOTING CORNER 1 2 /Ol -i ll..n 1^l�ll nlAll c rn!'11 flnr NOTES: SEE STRUCTURAL NOTES FOR TYPICAL TOP PLATE NAILING NOT SHOWN TYPICAL TOP PLATE SPLICE I 4 CRIPPLE STUDS AT 16" O.C. WHERE APPLICABLE TOP PLATES NAIL STUD TO HEADER W/ (8) 16d STUD(S) PER PLAN FULL HEIGHT TO TOP PLATES TRIM STUDS (TRIMMERS) PER POST PLAN TYPICAL SHEAR WALL SCHEDULE NUMBER OF SHEAR WALL STUD/BLKG. SILL PLATE / SOLE PLATE FRAMING ANCHOR TO NAIL/SCREW SHEATHED EDGE AT ADJOINING 67 SYMBOL SHEATHING SIDES 1 NAILING PANEL EDGES s SIZE CONCRETE s TO RIM JOIST SHEAR CLIPS SW1 1 8d @ 6" OC 2x 2x 5/8" DIA. AB 3"x.131" NAIL 3"x.131" TOENAIL 8 @ 48" OC @ 6" OC @ 6" OC SW2 1 8d @ 6" OC 2x 2x 5/8" DIA. AB 16d BOX NAIL LTP4 @ 24" OC SEE @ 48" OC @ 6" OC SW3 STRUCT 1 8d @ 4" OC 2x 2x 5/8" DIA. AB 16d BOX NAIL LTP4 @ 18" OC NOTES @ 32" OC @ 4' OC SW4 1 8d @ 3" OC Z 3x 4 2x 5/8" DIA. AB 16d BOX NA ZL LTP4 @ 14" OC @ 24" OC @ 3' OC SW5 1 8d @ 2" OC 3x 3x 2x 5/8" DIA. AB 16d BOX NAIL LTP4 @ 10" OC @ 18" OC @ 2.5" OC SHEAR WALL SCHEDULE NOTES 1. NAILS SHALL BE COMMON OR GALVANIZED BOX UNLESS NOTED OTHERWISE. 2. WHERE NAIL SPACING IS LESS THAN 4"oc, STAGGER NAILS %". 3. ALIGN ALL VERTICAL ADJOINING PANEL EDGES WITH STUD PER SCHEDULE. PROVIDE BLOCKING PER SCHEDULE AT ALL HORIZONTAL ADJOINING PANEL EDGES. 4. AT SW4 ONLY, 3x FRAMING MAY BE SUBSTITUTED WITH (2)2x NAILED TOGETHER W/ 3"0.131" NAILS @ 3" o.c EACH FACE. 5. AT SW1 PROVIDE STANDARD CUT WASHERS AT ALL SILL BOLTS. AT SW2 AND HIGHER PROVIDE 3"x3"x.223" STEEL PLATE WASHERS. LOCATE EDGE OF WASHER WITHIN YZ" OF EDGE OF SHEATHED SIDE OF SILL PLATE. HOLE IN WASHER MAY BE DIAGONALLY SLOTTED 1.75" MAX. 6. ENSURE ONE CLIP EACH END OF SHEAR WALL AT EACH REQUIRED FACE OF SHEATHING. 7. SHEAR CLIPS ARE REQUIRED ONLY AS INDICATED IN THE SECTIONS. 8. SEE DETAIL (TOP FAR RIGHT) FOR TYPICAL TOENAIL ROC' ROOF C( SF SHEAR WALL AT PERPENDICULAR RAFTERS 112 SOLID BLKG MATCH WIDTH OF BEAM/GIRDER TYPICAL HEADER DETAIL I rj SHEAR CLIPS PER SHEAR WALL SCHEDULE WHERE APPLICABLE TYP. SQUASH BLOCKS IN RIM JOISTS AT ALL POSTS AND HOLD-DOWNS, ALL LEVELS. SEE TYPICAL POST BLKG. DETAIL TYP. ANCHOR TYPE HOLD-DOWN W/ ANCHOR ROD PER HOLD-DOWN SCHEDULE TYP. 8d AT 12" o.c. NAILING AT ALL INTERMEDIATE SUPPORTS PANEL EDGE NAILING TYP. SILL/SOLE PLATE W/ ANCHORS PER SCHED. TYP. ANCHOR TYPE HOLD-DOWN PER PLAN WHERE APPLICABLE. SEE SCHEDULE FOR ANCHOR ROD TYP. ROOF BOUNC SHEAR WALL E SHEAR W, SHEAR WALL SW- ID SHEAR WALL KEY III III III III III III I -1r--IT-----IT--TF==; 1.1 I.I I I 1.1 1.1 1 II 1 II LI - - -r _ , I I I I 1�1 I�I j 1 I II II 11 I1 11 1 I I I I.I I I II II II 11 I SEGMENTAL SHEAR WALL S PER AT 48" o.c. SHEAR WALL AT PARALLEL RAFTERS 113 DIAPHRAGM NAILING SCHEDULE NAIL SPACING NAIL SPACING AT AT BOUNDARIES INTERMEDIATE NAIL SPACING BLKG SIZE OF AND "OTHER" FRAMING AT BLOCKED LOCATION SHEATHING REQD NAIL PANEL EDGES MEMBERS PANEL JOINTS ROOF SEE STRUCT NOTES NO 10d 6" OC 12" OC 6" OC SUB-FLR NO 10d & GLUE 6" OC 12" OC 6" OC DIAPHRAGM NOTES 1. ALL DIAPHRAGM SHEATHING IS TO BE STAGGERED IN THE DIRECTION OF THE PLYWOOD SPAN PER DIAPHRAGM DETAIL 2. PROVIDE BOUNDARY NAILING CONTINUOUS AROUND THE ENTIRE PERIMETER OF THE DIAPHRAGM 3. NAILS SHALL BE COMMON OR GALVANIZED BOX 4. ALL FRAMING MEMBERS SHALL BE 2x MINIMUM NOMINAL WIDTH BLOCKED DIAPHRAGM TYPICAL CONTINUOUS WHERE INDICATED I �PANELJOINT BOUNDARY NAILING BLOCKED CONTINUOUS PANELJOINT INTERMEDIATE NAILING TOP PLATE "OTHER" PANEL EDGE NAILING JOIST/TRUSS DIAPHRAGM DETAIL TYPICAL DIAPHRAGM NAILING 1 $ HOLD-DOWN ID BLKG PER SCHED AT HORIZ. PANEL JOINTS w/ EDGE NAILING BOTH SIDES OF JOI NIT TYP. - LOCATE VERTICAL PANEL JOINT ON STUD w/ EDGE NAILING BOTH SIDES OF JOINT - MIN (2) STUDS AT EACH HOLD-DOWN UNLESS NOTED OTHERWISE PER PLAN OR POST SCHEDULE TYP. - STRAP TYPE HOLD-DOWN PER PLAN TYP. TYPICAL TOENAIL a SHEAR WALL SCHEDULE AND NAILING DETAIL 1 9 BEAM PER PLAN (2) 16d TYP TOP PLATES (2) ROWS 16d @ 3" o.c. TYP SHIM EACH FACE AS NEEDED POST PER PLAN FULL HEIGHT STUD EACH SIDE OF POST. ATTACH WITH 16d AT 12" o.c. RIDGE BEAM TO POST 114 Ross Engineering Design Inc JOB # 17088 (425) 314-2373 ryan.ross@rossengineer.com ELECTRONIC COPY ORIGINAL ON FILE AT ROSS ENGINEERING DESIGN UF o _ Z U o t-m° mmy t o U o) m@ y a H Q°o'd o °L_'U20 a o 0 20 N � Z dw=Q�p O W, tco..�.cm�(-m� oym��2�3 ryaO �d w U J OO U�.p -'O a �O O LJ,-°° �O Co J Q O F O �O CV O 00 (>1 Q Z 0 Z O NNNIIN O Q 0 W 0 W 3i U Z I_.- W w 1121:� W R- � CV 0 Q 00 a� R G c O EL 0 O IZI FILE/ NO. DATE DESIGNED BY RR DRAWN BY RR CHECKED BY RR SHEET: S1 PRINT DATE 5 / 29 / 2020 TYPICAL ASSEMBLY UNLESS NOTED OTHERWISE IN DETAILS. SHOWN WITH OPTIONAL TRUSS ROOF 1" AIR SPACE w/ CARDBOARD BAFFLE. EXTEND 24" ABOVE INSULATION VENT BLOCKS w/ (3) 2" dia. WIRE SCREENED VENT HOLES @ EA. BLOCK CONT. ALUM. GUTTER ON FASCIA BOARD PER ELEVATIONS j OVERHANG I. PER PLAN SIDING PER ELEVATION o/ 15# PAPER OR AIR INFILTRATION BARRIER o/ %6" APA RATED 24/16 SHEATHING NAILED w/ 8d @ 6" EDGE, 12" FIELD O.C. (U.N.O. IN SHEAR WALL SCHEDULE). o/ 2x6 STUDS @ 16"O.C. w/ R-21 BATT. INSULATION (HEATED AREAS ONLY) &%" GWB AT INTERIOR FACE 2x6 BASE PLATE RIM JOIST PER PLAN R-30 BATT INSULATION ROOFING PER ELEVATIONS o/ 30 # FELT OVER %6"APA RATED 24/16 SHEATHING ON OPTIONAL MANUF. TRUSSES R-49 BATT OR BLOWN INSUL. (HEATED AREAS ONLY) YZ" CEILING G.W.B. (2) 2x6 TOP PLATES STAGGER JOINT MIN. 48"O.C. 3/4" T&G PLY OR EQUIV. SUB -FLOOR GLUED & NAILED TO FLOOR JOISTS. u V I Il P.T. 2x6 MUD SILL w/ ANCHOR BOLTS PER SHEAR WALL SCHEDULE. 4" TIGHTLINE DRAIN �" WHERE REQ'D 1! II FOUNDATION WALL SIZE AND z_ 4" PERF. FT'G DRAIN. REINFORCING PER PLAN WRAP IN FILTER FABRIC w/ GRAVEL OVER. FOOTING SIZE AND REINFORCING PER PLAN. ) �11 z w J O p a 9 ,ik -� (_6 MIL BLACK V.B. PER PLAN TYPICAL ONE STORY ASSEMBLY SCALE: 3/4" = V-0" MAIN FLOOR PLATE 8'-0" (verify) MAIN FLOOR ROOFING PER ELEVATIONS o/ 30 # 1" AIR SPACE FELT OVER %6'APA RATED 24/16 SHEATHING RIPPED BLOCKS w/ (3) 2" dia. HOLES OR (3) 1" "V" NOTCH w/ WIRE SCREEN BETWEEN EACH RAFTER w it OVERHANG PER PLAN RAFTERS TO WALLS SCALE: 3/4" = 1'-0" 12" dia. CONCRETE SONO TUBE TO GRADE R-38 HIGH DENSITY BATT INSUL. (HEATED AREAS ONLY) RAFTERS PER ROOF PLAN %" CEILING GWB SIMPSON H-1 TIES @ EA. RAFTER SEE TYP. ASSEMBLY BEAM PER PLAN CAP PER SCHEDULE POST PER SCHEDULE BASE PER SCHEDULE ..... - -- 11 4 (3) #4 BARS z Hi 11 II ;; FOOTING & REINFORCING a PER SCHEDULE - z a Q ii n n /% BEARING SOIL PER PLAN EXTERIOR FOOTING AND POST / SCALE: 3/4" = 1'-0" BUILDING SECTION. S2 SCALE: 1/4" = 1'-0" 2x_ ROOF OVER FRAMING SCALE: 3/4" = 1'-0" DECK PER PLAN RIPPED 2x8 P.T. @16" O.C. CONCRETE LANDING EXTERIOR DECK & STEP SCALE: 3/4" = 1'-0" FRAMING MEMBERS BELOW ROOF SHEATHING AS PER PLAN MIN. 2x6 BLOCK BETWEEN FRAMING MEMBERS w/ (2) 16d NAILS EA. SIDE 2x6 VALLEY BOARD w/(2) 16d NAILS INTO EA. FRAMING MEMBER BELOW 2x4 RAFTERS @24"O.C. BRACED DOWN TO FRAMING MEMBER BELOW @48"O.C. 2x6 RIDGE BOARD DECK & JOISTS PER PLAN BEAM PER SCHEDULE BEAM PER PLAN w/ SIMPSON "MSTC28" TIES @ ALL HORIZ. SPLICES. POST CAP OR GUSSET PER SCHEDULE POST PER SCHEDULE [)fz W J 0- A ISOLATED FOOTING / SCALE: 3/4" = 1'-0" TYP. ASSEMBLY 4"x4" L- FLASHING MIN. DECKING & JOISTS PER PLAN Y4' T&G APA 48/24 RATED SHEATHING GLUED & NAILED TO FLOOR JOISTS FLOOR JOIST PER PLAN LAP JOISTS MIN. OF 6" & NAIL w/ (3) 10d FACE NAILS (IF REQURIED) SOLID BLOCKING OVER BEAM BASE PER SCHEDULE FOOTING & REINFORCING PER SCHEDULE TYP. ASSEMBLY i II a 1' -2" a a"x3 2" SIDS@ 7" O.C. STAGGERED a NOTE: HANGERS PER SCHEDULE ,)/a CAP PER SCHEDULE DTT1Z EACH END &12'-0" O.C. POST PER SCHEDULE MUD SILL& BOLT PER PLAN a FOUNDATION PER DETAIL 1. ALL DECKING MATERIAL SHALL CONFORM w/ I.R.C. & LOCAL CODES. 2. NAIL ALL DECKING OR SHEATHING TO JOISTS w/ RING SHANKED HOT DIPPED GALV. NAILS. o EXTERIOR DECK TO RIM JOIST SCALE: 3/4" = V-0" EMBED REBAR INTO XIST'G STEM WALL (DRILL & EPDXY MIN. 4" INTO STEM WALL) MATCH TO STEM WALL REINF. MIN. (1) TOP & BOTTOM BARS I I XIST'G STEM y WALL /I a XIST'G ' FOOTING ' ° 11 �. d EMBED REBAR INTO \ XIST'G FOOTING (DRILL & EPDXY MIN. 4" INTO STEM WALL) ° MATCH TO FT'G REINF. EXISTING FOUNDATION TO NEW SCALE: 3/4" = 1'-0" CEILING FRAMING PER PLAN SIDING INSTALLED PER MANUF. SPECIFICATION EXTERIOR TRIM PER PLAN 4"x- "L" METAL FLASHING w/ DRIP EDGE INSTALLED UNDER BARRIER _ NEW STEM WALL NEW FOOTING �- DBL. 2x6 TOP PLATES 2" RIGID R-10 INSULATION INSTALLED IN CAVITY BETWEEN HEADER & INTERIOR G.W.B. HEADER PER PLAN SEALANT j WINDOW FINISH AND TRIMS PER OWNER SPECS. I HEADER INSULATION DETAIL SCALE: 1 1/2" = 1'-0" EXTERIOR WALLS NOT MARKED SHALL BE SW1 HOLDDOWNS CALLED OUT ARE LOCATED AT BASE OF SHEAR WALLS. SEE SHEET S1 FOR SHEAR WALL SCHEDULE E; -------------------- n �--T_________________________ n u MAIN FLOOR SHEARWALLS SCALE: 1/8" = 1'-0" Z N W o >m Q > U CL YwxaiT d Of ��a O 0:; J V U �Loo Z coo= co N N W � .m 0 W m o W H E V C + C1 .y sC ALA,, W Z U E N o Z ~O o� _o-n2N pm=cm'_o��� O N a d a a m y c } Z Q f6 N U.N o c aw o J��._�ca�ao2a�= o OLU �w �po�3mi.c_p-Op 0w0 n"a3-lj 3OJ 0 g o o w s d �' > F E m m J Q O F O 6/1/2020 y p,N N. R0S OF WAS,yi,� S 17 88 46411 GISTVE �4NALE ELECTRONIC COPY ORIGINAL ON FILE AT CD ENGINEERING DESIGN CD O�1 Q z 0 V) 0 z O O Q 0 W 0 W U Z V) W Lu Lu Immom Z � � CV 011 Q Im O 00 0 0 :r a 0 d 0 G Z PROJECT NO. 200506 DESIGNED BY TL DRAWN BY TL & RIM CHECKED BY RR SHEET: S2 PRINT DATE 5/30/2020 9:50 AM FOUNDATION NOTES • VERIFY ALL DIMENSIONS AND FIELD CONDITIONS PRIOR TO COMMENCING ANY WORK. • GENERAL CONTRACTOR AND/OR FOUNDATION CONTRACTOR SHALL A o cNi l B VERIFY THE LOCATION OF ANCHOR BOLTS AND HOLDOWNS PRIOR TO r U POURING CONCRETE. 15' 0" 1'-6" 6'-0" 6' 1'-6" • ALL FOOTING SHALL BEAR 18" BELOW UNDISTURBED NATURAL SOIL. FINISHED GRADE SHALL BE NO LESS THAN 12" ABOVE BOTTOM OF F-03 F-03 Q F— 3 FOOTINGS. • TOP OF FOOTING SHALL BE LEVEL. BOTTOM SURFACE OF FOOTING SHALL NOT SLOPE MORE THAN 10%. STEP FOOTING AS NECESSARY TO MAINTAIN MIN. DEPTH OF FOOTING BELOW FINISHED GRADE. S2 • FOUNDATION WALL SHALL EXTEND MINIMUM 6" ABOVE FINISHED GRADE. • ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED. • UNLESS NOTED OTHERWISE OR IN SHEAR WALL SCHEDULE, ALL ANCHOR BOLTS SHALL BE 2" dia. x 10" AND EXTEND MINIMUM 7" INTO CONCRETE WITH MINIMUM SPACING OF 48" ON CENTER. EACH ANCHOR BOLT SHALL HAVE A 3"x3"x.229" GALVANIZED WASHER. • SEE SHEARWALL & HOLDOWN SCHEDULES FOR SIZE AND PLACEMENT. • CRAWLSPACE ACCESS SHALL BE A MIN. OF 18"x24". OPENINGS THROUGH A PERIMETER WALL SHALL BE NOT LESS THAN 16"x24". (R408.4) • PROVIDE A 6 MIL. BLACK VAPOR BARRIER OVER ALL CRAWLSPACE AREAS. (R406.3.2) • PROVIDE 2" SAND OVER 6 MIL BLACK VAPOR BARRIER OVER 4" COMPACTED GRANULAR FILL UNDER ALL CONCRETE SLABS. • PROVIDE TEMPORARY BRACING AS REQUIRED UNTIL ALL PERMANENT CONNECTIONS ARE IN PLACE. • ALL ISOLATED SPREAD FOOTING TO BE 24"x24"x8" REINFORCE FOOTINGS WITH (2) #4 BARS EACH WAY UNLESS NOTED OTHERWISE IN PLAN. • FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE INTERIOR SPACES AND FLOORS BELOW GRADE SHALL BE DAMPPROOFED FROM TOP OF FOOTING TO FINISHED GRADE. (R406.1) • SEE SIMPSON RECOMMENDATIONS FOR HOLD DOWN PLACEMENT. COORDINATE LOCATIONS WITH DOOR & WINDOW ROUGH FRAMING TO PROVIDE ACCURATE DIMENSION FOR OPENINGS. FOUNDATION VENT CALCS. (R408.1) PROVIDE 1 SQ. FT. OF VENTILATION FOR EVERY 300 SQ. FT. OF CRAWLSPACE. FOUNDATION VENTS SHALL BE EXTRUDED, LOAD BEARING 16"x8" VENTS. PROVIDE A MINIMUM OF (1) FOUNDATION VENT WITHIN T-0", BUT NOT WITHIN THE FIRST V-0" OF EACH CORNER OF CRAWLSPACE. ASSUMED VENTS ARE MIN. 15.5"x6" AND HAVE A NET FREE VENTILATION AREA OF .48 SQ. FT. TOTAL CRAWLSPACE AREA = 245 SQ. FT. / 300 = 0.82 SQ. FT OF NET VENTILATION REQ'D. 0.82 SQ. FT. DIVIDED BY .48 = 2 VENTS NOTE: VENT SIZES MAY VARY AND MESH OR LOUVERS MAY DECREASE THE NET FREE VENTILATION AREA. CONTRACTOR TO VERIFY CALCULATIONS AND PROVIDED NEEDED VENTILATION BASED ON ACTUAL VENT SIZE, DESIGN, AND LOCATION. FOUNDATION PLAN SCALE: 1/4" = 1'-0" q ao NOTE ! ALL FOUNDATION WALLS TO BE 6" UNLESS CALLED OUT OTHERWISE. LEGEND STEM WALL — FOOTING CONCRETE SLAB EXISTING STEM WALL EXISTING FOOTING CONCRETE FOOTING SCHEDULE SYM. FOOTING SIZE RE -BAR PLACEMENT F-01 *12"x6" CON'T. (2) #4 CON'T. F-02 24"x24"x8" (2) #4 EA. WY. F-03 "24"x24"x8" (2) #4 EA. WY. F-04 �30"x24"ff' (3) #4 EA. WY. NOTE: "EXTERIOR FOOTINGS SHALL BE MIN. 18" BELOW GRADE AND REST ON BEARING SOIL. V z � N CD W 00 Q � U IL Y 2 a wa'� w ,n � O "�� J V � U z 00o.. 00 N '- Lu 99 0 Lu m J 0 W Air E 0 V C .N a� C ZoE� 9�osm�a�0 c° Y o 1.c� ti° E m y m o E O N p =OJm _a ��asmm O-o m�in2 OUm m�'mNmE om c Z Q ap LL° y o c 3- T p �.� N o U Lu 0 0"� @ �_ O a> o c c— 3 —_ m Lu ° c ? N 0,5 L N d > F J Q F O 6/1/2020 yPNN.Ro OF WA S y c� o JJ B# 17 88 46411 GISTER�� FSS�QW- ELECTRONIC COPY 1-0 ORIGINAL ON FILE AT O ROSS ENGINEERING DESIGN 0 011 Q z 0 IC) z O O Cl Q LLJ 0 W V z W LLJ LLJ V) W 1-0 � N Q 0 00 a� a 0 c 0 a �L V 0 VM PROJECT NO. 200506 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY RR SHEET: S3 PRINT DATE 5/30/2020 9:51 AM ROOF PLAN NOTES • SEE DESIGN LOADS AND/OR STRUCTURAL NOTES FOR GROUND AND ROOF SNOW LOADS. • FOR MANUFACTUREDED TRUSS ROOFS: ROOF PLAN IS FOR SCHEMATIC PURPOSES ONLY. ACTUAL ROOF PLAN TO BE DESIGNED AND ENGINEERED BY A LICENSED TRUSS ENGINEER. RAFTER FRAMING PER PLAN. • TRUSS LAYOUT TO BE REVIEWED AND APPROVED BY THE TRUSS MANUFACTURER PRIOR TO CONSTRUCTION. • SHADED AREAS INDICATE OVER -FRAMING. • LOCATE DOWNSPOUTS PER SITE CONDITIONS AND PER GENERAL CONTRACTOR. • INSTALLATION OF ALL ROOFING AND WALL FLASHING SHALL BE TO INDUSTRY STANDARDS AND IN COMPLIANCE WITH CURRENT CODES. • PROVIDE CONTINUOUS ALUMINUM GUTTERS ON FASCIA AS SPECIFIED IN DETAILS. • SKYLIGHT SIZES, IF ANY, ARE APPROXIMATE. CONTRACTOR TO VERIFY ACTUAL ROUGH OPENING SIZE PER MANUFACTURER SPECIFICATIONS. • PROVIDE SOLID BLOCKING OVER ALL SUPPORTS. • PROVIDE MIN. 22"x30" ATTIC ACCESS WITH APPROVED WEATHERSTRIPPING. IF ACCESS IS IN A GARAGE, A SELF CLOSING MECHANISM MUST BE INCORPORATED. • 16d @ 8"o.c. END TRUSS TO TOP PLATES. (TYPICAL AT ALL GABLE ENDS) • ATTICS WHERE THE MAX. CLEAR HEIGHT BETWEEN JOIST AND RAFTERS IS MORE THAN 42", OR WHERE THERE ARE TWO OR MORE ADJACENT TRUSSES WITH THE SAME WEB CONFIGURATION CAPABLE OF CONTAINING A RECTANGLE 42" HIGH BY 24" WIDE OR GREATER, MUST BE CONSIDERED ATTIC WITH LIMITED STORAGE. • ATTIC SPACE SERVED BY A FIXED STAIR SHALL BE DESIGNED TO SUPPORT THE MIN. LIVE LOAD FOR SLEEPING ROOMS. ATTIC VENTILATION CALCULATIONS ATTIC VENTILATION (R806.1 & 806.2) PROVIDE 1 SQ. FT. OF ATTIC VENTILATION FOR EACH 150 SQ. FT. OF ATTIC AREA. EXCEPTION: PROVIDE 1 SQ. FT. OF ATTIC VENTILATION FOR EACH 300 SQ. FT. OF ATTIC SPACE WHEN 50% (BUT NOT MORE THAN 80%) OF VENTILATION IS IN THE UPPER Y3 OF ATTIC. PROVIDE A COMBINATION OF ROOF JACKS OR CONTINUOUS RIDGE VENTING ALONG WITH EAVE VENTS. AF50 JACK VENTS =. 333 SQ. FT. NET FREE AREA. EAVE BIRD BLOCKS = .074 SQ. FT. NET FREE AREA. CORAVENT V300 = .094 SQ. FT. NET FREE AREA PER L.F. NEW ROOF AREA ROOF AREA = 374 SQ. FT. / 300 = 1.25 SQ. FT. / 2 = .62 SQ. FT. OF REQUIRED VENTING IN BOTH UPPER 50% OF ROOF AND IN LOWER 50% OF ROOF. IN UPPER 50% OF ROOF TOTAL SQ. FT. REQUIRED / .333 = 2 AF50 JACK VENTS. IN LOWER 50% OF ROOF TOTAL SQ. FT. REQUIRED / .074 = 9 EAVE BIRD BLOCKS A MATCH I U \ < °� GABLE WALL r I I I I 1 OPTIONAL 2 S2 S2 i CUT AND REMOVE EXISTING OVERHANGS AS NEEDED. ------ ----- ---------- - ----- ---------- zi=il II L I I Lu LLI co II II II II II II II II II II II II II II II II II II II II II II II II II II I; II I II II II II II II II II II II II -7 II II I� II II II II jl II II II II II I� II II I II II _J I� II II ______ II II E--_-_-_-_ ----- ----- -- -- ----- ---I II II XISTIN RID E II II II II II II II II II II II NO CALLOUTS SHALL BE HEADER: BM-01 COLUMN: P-01 (ea. side) LEGEND RAFTERS OVER FRAMING WALLS UNDER HEADERS & BEAMS ROOF LINES EXISTING WALLS UNDER EXISTING HEADERS & BEAMS EXISTING REMOVED ROOF PLAN SCALE: 1 /4" = V-0" FOR SCHEMATIC PURPOSES ONLY. REFER TO TRUSS FRAMING PLANS PER MANUFACTURER AND PREPARED BY A LICENSED TRUSS ENGINEER. I I I I I I I I I r� v N E-1 �1 \ II jj II II II mll � 3:12 0 3:12 (9 (ver II II II II — I I 'le B --- I I I I I I 1 I I Lam, I "f I 2 12 S1 A �X I ' ---- ------ I I i i FRAMING EXISTING ■l L L — T — F- �� ___ __ __ __ __ __ __--I r--- -- ----- ----- -----1 l X w co I LJ I I I II I I II Ilj I II II I I II II I I II II I I r� I I I I I I II I r---- -�1F ---J-� II L--- ---- — ----� I II I POST, CAP & BASE SCHEDULE SYM. POST CAP BASE NOTES: P-01 (1) 2x_ STUD w/ (1) TRIMMER (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER P-02 2x_ STUD w/ (2) TRIMMERS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. (8) 16d NAILS STUD TO HEADER P-03 (2) 2x— TRIMMERS (4) 16d NAIL (HEADER) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-04 (2) 2x_ STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-05 (3) 2x_ STUDS (4) 16d NAIL (DBL. TOP PLATE) (4) 16d NAIL (TOE PLATE) 16d NAILS STAGGERED @ 12" O.C. P-06 44 DF#2 ` SIMPSON PC44 SIMPSON A-35 * OPTION: 2x4 CLEAT EA. SIDE NAILED w/ (2) ROWS OF 10d @4"O.C. P-07 4x6 DF#2 ` SIMPSON PC44 SIMPSON A-35 ` OPTION: 2x4 CLEAT EA. SIDE NAILED w/ (2) ROWS OF 10d @4"O.C. P-08 44 P.T. EPC4Z PBS44A P-09 4X6 DF#2 SEE 14/S1 (4) 16d NAIL (TOP PLATE) P-10 4X4 DF#2 EPC4Z (2) A34 w/ SD#9's (BEAM) NOTE: SOLID BLOCKING BETWEEN FLOOR @ POINT LOAD BLOCKING TO BE EQUAL TO OR GREATER THEN THE POST ABOVE BEAM SCHEDULE SYM. BEAM BM-01 48 DF#2 OR BETTER BM-02 410 DF#2 OR BETTER BM-03 (2)- 2x8 (min.) BM-04 410 P.T. BM-05 (2) 2x10 DF#2 BM-06 3.5"x12" GLULAM BM-07 3.5"x10.5" GLULAM BM-08 3.5"x9.25" PSL HANGER SCHEDULE SYM. HANGER H-01 LU210 H-02 LU28 (min.) H-03 LU28 / LUC28 H-04 LSU26 NOTE: HANGERS NOT CALLED OUT IN ROOF PLAN SHALL BE PROVIDED BY TRUSS ENGINEER LEGEND CONCRETE WALL UNDER WALLS/ FIXTURES OVER FLOOR PERIMETER 2x10 FLOOR JOISTS DECK JOISTS HEADERS & BEAMS CONCRETE SLAB CONCRETE CONCRETE WALL UNDER EXISTING REMOVED A RIPPED 2x8 P.T. STEP OVER CONCRETE PAD @16"O.C. SIN 0 ti O� BM-04 0 —✓ o Iq P.T1 2x8 J ISTS 16" .C. I N DO cn ---------- ., I . • I A I I O Lu O m i. I m off w 1 " I m J O la OW U i. N O J 0CD N 4 I= I I I I Z a U ° I P MI / °I I I I° - - I MAIN FLOOR FRAMING SCALE: 1 /4" = V-0" --------- 2 1\ �S2, --------- 0 U z 00 � N 0 0 >M Q > U CL Y x iT wad w�� OJ V � U M w Z (o o c co N N W � .M o M W m IL H E O V C + C1 .y L o uj ami _m `o -p da owo0 ozZ'o ooc�������° UI O. a _ 0_ p a ib O O O- N a d a a m `o m y IfNm yi od.c E}a ZwJ oU aE O d oO Y 0 L,o c E > Lu O�3oE,aM mwn o 20y20sa c5op ;u �'>FEmm J Q O F O 6/1/2020 y p,N N . RCS Q� OF WA S 17 88 46411 GISTvE �4NAl- ELECTRONIC COPY ORIGINAL ON FILE AT O ROSS ENGINEERING DESIGN 00 Cr z >Q cn z O O 0 LLj Q W U z W Lw Lj h V) W No CN 011 Q CD 00 N 0 C O :r C. �L V 0 O Z PROJECT NO. 200506 DESIGNED BY TL DRAWN BY TL & RM CHECKED BY RR SHEET: PRINT DATE 5/30/2020 9:52 AM