RED HAWK FIRE PROTECTION, LLC 801 Valley Avenue N.W. Suite D Puyallup, WA 98371 (253) 840-9900 '7 - 1;c/e- V Aal(e FIRE SPRINKLER EQUIPMENT SUBMITTAL FOR CROUCH-MAUPIN RESIDENCE EDMONDS, WA RHFP JOB NO. 80260 Pipe & Fittings SPEARS FlameGuard' CP VC FIRE SPRINKLER PIPING PRODUCTS TECHNICAL INFORMATION WEIGHTS & DIMENSIONS C E R LPCB 0- UKAS MANAGEMEN T SYSTEMS 007 Assessed to ISO 9001: 2008 Certificate number 293 November 2015 SUPERSEDES ALL PREVIOUS EDITIONS Visit our • www.spearsmfg.com FG-4-1115 El FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS The information contained in this section is based on current information and Product design at the time of publication and is subject to change without notification. Our ongoing commitment to product improvement may result in some variation. No representations, guarantees or warranties of any kind are made as to its accuracy, suitability for particular applications or results to be obtained therefrom. For verification of technical data or additional information not contained herein, please contact Spears® Technical Services Department [West Coast: (818) 364-1611—East Coast: (678) 985-1263]. General Information RECOMMENDATIONS FOR INSTALLERS AND USERS: Plastic piping systems should be ENGINEERED, INSTALLED and OPERATED in accordance with ESTABLISHED DESIGN AND ENGINEERING STANDARDS AND PROCEDURES for plastic piping systems. Suitability for the intended service application should be determined by the installer and/or user prior to installation of a plastic piping system. All Installation and maintenance personnel should be trained in the proper handling and installation requirements and precautions of plastic piping systems. PRIOR TO ASSEMBLY, all piping system components should be inspected for damage or irregularities. Mating components should be checked to assure that tolerances and engagements are compatible. Do not use any components that appear irregular or do not fit properly. Contact the appropriate manufacturer of the component product in question to determine usability. Consult all applicable codes and regulations for compliance prior to installation. Installation must be made in accordance with Spears® Manufacturing Company FlameGuard® CPVC Fire Sprinkler Piping Products Installation Instructions - FG-3 NOTE — Individual or group instruction in correct solvent welding procedures is available by contacting your local distributor or your servicing Spears® Regional Distribution Center. SOLVENT CEMENT CONNECTIONS — Spears® Manufacturing Company recommends the use of Spears® FS-5 One Step solvent cement for joining Spears® products. Use of solvent cementing products not approved for CPVC fire sprinkler systems, or failure to follow installation instructions will automatically void the warranty. THREADED CONNECTION — Spears® Manufacturing Company recommends the use of Spears® BLUE 75TM Thread Sealant. This product has been tested by Spears® and the sealant manufacturer for compatibility with the Spears® CPVC fire sprinkler products. Consult the sprinkler head manufacturer before using this product. WARNING: OTHER PIPE JOINT COMPOUNDS OR PASTES MAY CONTAIN SUBSTANCES THAT COULD CAUSE STRESS CRACKING IN THE CPVC OR OTHER FITTING COMPONENTS. Care must be taken to avoid over torquing - generally 1 to 2 turns beyond finger tight is all that is required to make up a threaded connection. Factory testing has indicated 10-25 ft. lbs. of torque is adequate to obtain a leak free seal. GASKET SEALED THREAD CONNECTIONS — This type of connection can only be made with Spears@ TorqueSafe TM, SofTorqueTM or QuickTorqueTM style Gasket Sealed Female Sprinkler Adapters. DO NOT USE ANY TYPE OF THREAD SEALANT WHEN INSTALLING THIS TYPE OF ADAPTER. Tape or paste may impair proper sealing and function. Testing has shown that hand tight until snug for the TorqueSafeTm adapter and finger tight plus 1-turn is all that is needed to seal this special connection. Sprinkler heads in these specialty fittings can then be additionally tightened clockwise to bring sprinkler frames into desired alignment without stressing the fitting. See specific adapter instructions in package for details. GripLocTm CONNECTIONS — This type of connection can only be made with Spears@ GripLocTM Couplings or Repair Couplings. DO NOT USE ANY TYPE OF SOLVENT CEMENT OR SEALANT WHEN INSTALLING THIS TYPE OF CONNECTION. Uses an internal stainless steel gripper ring with an internal elastomer gasket seal. Connection allows immediate system use. See specific instructions in package for details. Installation Training Available - Contact Spears® Technical Services for Details FlameGuard® Products must be installed in accordance with Spears® FlameGuard® CPVC Fire Sprinkler Piping Products Installation Instructions, National Fire Protection Association Standards 13, 13R, 13D, and in accordance with local codes. Code requirements and field conditions may differ. It is the responsibility of the installing contractor to insure that the product is suitable to meet these requirements. Dimension Reference G = (LAYING LENGTH) Intersection of center lines to bottom of socket/thread; 90' elbows, tees, crosses; ± 1/32 inch. M = Outside diameter of socket/thread hub; ± 1/16 inch. H = Intersection of center lines to face of fitting; 90° elbows tees, crosses; ± 1/32 inch. N = Socket bottom to socket bottom; couplings; ± 1/16 inch. J = Intersection of center lines to bottom of socket/thread; 45' elbows; ± 1132 inch Q = Width of flats; ±1/16 inch. L = Overall length of fittings; ± 1/16 inch. W = Height of cap; ± 1/16 inch. CPVC FIRE SPRINKLER PIPE SDR 13.5 (ASTM F 442) Part Number Nominal Size Average O.D. I Average I.D. Approx. Weight Lbs./Ft. Inches (mm) Inches (mm) Inches (mm) CP-007 3/4 (19.1) 1.050 (26.7) .874 (22.5) 0.168 CP-010 1 (25.4) 1.315 (33.4) 1.101 (28.2) 0.262 CP-012 1-1/4 (31.8) I 1.660 (42.2) 1.394 (35.6) 0.418 CP-015 1-1/2 (38.1) 1.900 (48.3) 1.598 (40.7) 0.548 CP-020 2 (50.8) 2.375 (60.3) 2.003 (50.9) 0.859 CP-025 2-1/2 (63.5) 2.875 (73.0) 2.423 (61.5) 1.257 CP-030 3 (76.2) 3.500 (88.9) 2.950 (75.0) 1.867 "Lead Free" low lead certification — unless other wise specified, all Spears® FlameGuard® fittings specified here -in are certified by NSF International to ANSI/NSF® Standard 61, Annex G and is in compliance with California's Health & Safety Code Section 116825 (commonly known as AB1953) and Vermont Act 193. Weighted average lead content-0.25%. Spears® PVC and CPVC Pipe, Fittings and Valves have always been lead-free and Certified by NSF International for use in potable water systems. Spears® offers a wide range of lead-free specialty fittings and transition adapters for plumbing applications. However, certain brass threaded adapter fittings for applications that are not intended to convey water for human consumption through drinking or cooking are still produced and available. SPEARS® MANUFACTURING COMPANY FlameGuar& CPVC FIRE SPRINKLER PIPING PRODUCTS El SOCKET DIMENSIONS �~ C SCH 40 - ASTM F438 SCH 80 - ASTM F439 B A Socket Socket SCH 40 Minimum SCH 80 Minimum Size Tolerance Entrance A Bottom B Socket Length C Socket Length C 3/4 1.058 1.046 ± .004 .719 1.000 1 1.325 1.130 ± .005 .875 1.125 1-1/4 1.670 1.655 ±.005 .938 1.250 1-1/2 1.912 1.894 ± .006 1.094 1.375 2 2.387 2.369 ± .005 1.156 1.500 2-1/2 2.889 2.868 ± .007 1.750 1.750 3 3.516 3.492 ± .008 1.875 1.875 TEE Socket x Socket x Socket 1 I M-- --I- 1 H�G L H � L Part Number Size G H L M Approx. Wt. (Lbs.) 4201-007 3/4 9/16 1-1/2 2-31/32 1-5/16 .11 4201-010 1 7/8 1-13/16 3-5/8 1-5/8 .20 4201-012 1-1/4 15/32 2-3/32 4-7/32 2 .29 4201-015 1-1/2 1-5/32 2-9/16 5-3/32 2-11/32 .54 4201-020 2 1-13/32 2-15/16 5-7/8 2-7/8 .86 4201-025 2-1/2 1-23/32 3-1/2 7 3-15/32 1.62 4201-030 3 2-1/16 3-31/32 7-15/16 4-5/32 2.53 REDUCING TEE [--tml Socket x Socket x Socket H1 } } H1 MM2 � In. G1 LGHt2-- Part Approx. Size G G1 G2 H H1 H2 L M M1 M2 Number Wt. (Lbs.) 4201-102 3/43/41 3/4 3/4 3/4 1-11/16 1-25/32 1-11/16 3-13/32 1-5/16 1-21/32 1-5/16 .13 4201-125 1x3/43/4 23/32 7/8 23/32 1-25/32 1-13/16 1-21/32 3-7/16 1-19/32 1-11/32 1-5/16 .16 4201-126 1xNA 23/32 23/32 3/4 1-27/32 1-27/32 1-3/4 3-19/32 1-5/8 1-5/8 1-5/16 .17 4201-131 1x10/4 11/16 13/16 11/16 1-13/16 1-13/16 1-13/16 3-5/8 1-5/8 1-5/16 1-5/8 .17 4201-157 1-1/410/4 11/16 1-1/32 11/16 1-15/16 2-1/32 1-13/16 3-25/32 2-3/32 1-13/32 1-23/32 .32 MADE IN THE U.S.A. El FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS REDUCING TEE (continued) r--►rM1 Socket x Socket x Socket � M H1 M G1 LH G2 f H2 L Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx. Wt. (Lbs.) 4201-158 1-1/41x1 27/32 29/32 25/32 2-1/16 2-1/32 1-29/32 3-15/16 1-31/32 1-5/8 1-5/8 .24 4201-159 1-1/41x1-1/4 31/32 31/32 31/32 2-7/32 2-7/32 2-3/32 4-11/32 2-1/8 2-1/8 1-23/32 .36 4201-167 1-1/41-1/43/4 21/32 1 21/32 1-29/32 2 1-29/32 3-13/16 2 1-5/16 2 .22 4201-168 1-1/41-1/4x1 13/16 1 1 13/16 2-1/16 2-1/8 2-1/16 1 4-1/8 1-31/32 1-21/32 1-31/32 .24 4201-169 1-1/4x1-1/4x1-1/2 1-1/8 15/16 1-1/8 2-3/8 2-11/32 2-3/8 4-3/4 2-3/32 2-11/32 2-3/32 .51 4201-201 1-1/2xl-1/43/4 11/16 1 1/4 2-1/16 2 1-15/16 4 2-5/16 1-3/8 2-1/16 .41 4201-202 1-1/2xl-1/4xl 27/32 1-1/32 1 2-7/32 2-5/32 2-1/4 4-15/32 2-5/16 1-11/16 2-1/16 .42 4201-210 1-1/2xl-1/2x3/4 11/16 1-1/32 11/16 2-1/16 2-1/32 2-1/16 4-5/32 2-11/32 11-13/32 2-11/32 .39 4201-211 1-1/2xl-1/2xl 13/16 1-3/32 13/16 2-3/16 2-1/4 2-3/16 4-3/8 2-11/32 1-3/4 2-11/32 .41 4201-212 1-1/2xl-1/2xl-1/4 1-1/32 1-3/32 1-1/32 2-13/32 2-11/32 2-13/32 1 4-13/16 2-11/32 2-1/8 2-11/32 1 .49 4201-213 1-1/2xl-1/2x2 1-9/32 1-5/32 1-9/32 2-21/32 2-21/32 2-21/32 5-11/32 2-11/32 12-29/32 2-11/32 .64 4201-248 2x2x3/4 11/16 1-13/32 11/16 2-7/32 2-7/16 2-7/32 4-7/16 2-27/32 11-3/8 2-27/32 .52 4201-249 2x2xl 27/32 1-13/32 27/32 2-11/32 2-9/16 2-11/32 4-23/32 2-7/8 1-3/4 2-7/8 .58 4201-250 WA-1/4 1-1/32 1-11/32 1-1/32 2-17/32 2-19/32 2-17/32 5-3/32 2-7/8 12-3/32 2-7/8 .65 4201-251 WA-1/2 1-5/32 1-7/16 1 1-5/32 2-11/16 2-13/32 2-11/16 5-3/8 2-7/8 12-13/32 2-7/8 .79 4201-289 2-1/2x2-1/2xl 27/32 1-23/32 27/32 2-5/8 2-27/32 2-5/8 5-1/4 3-17/32 1-23/32 3-17/32 1 1.01 4201-290 2-1/2x2-1/2xl-1/4 1-3/32 1-23/32 1-1/32 2-13/16 2-31/32 2-13/16 5-21/32 3-9/16 2-3/32 3-9/16 1.13 4201-291 2-1/2x2-1/2xl-1/2 1-3/16 1/2 1-3/16 2-15/16 1-7/8 2-15/16 5-7/8 3-15/32 12-11/32 3-15/32 1.26 4201-292 2-1/2x2-1/2x2 1-13/32 1-5/8 1-13/32 3-3/16 3-1/8 3-3/16 6-3/8 3-1/2 12-7/8 3-1/2 1.37 4201-335 3x3x1 7/8 1-15/16 7/8 2-3/4 3-1/16 2-3/4 5-15/32 4-3/16 1-23/32 4-3/16 1.26 4201-336* 300-114 1-3/8 1-3/4 1-3/8 3-5/16 3-1/2 3-5/16 6-5/8 4-1/8 12-7/8 4-1/8 1.94 4201-337 30A-1/2 1-5/32 2-1/16 1-5/32 3-1/32 3-7/16 3-1/32 6-3/32 4-3/16 12-3/8 4-3/16 1.46 4201-338 3x3x2 1-7/16 1-13/16 1-7/16 3-5/16 3-5/16 3-5/16 6-19/32 1 4-3/16 2-7/8 4-3/16 1.69 4201-339 3x3x2-1/2 1-3/4 1-31/32 1-3/4 1 3-5/8 3-23/32 3-5/8 7-1/4 1 4-3/16 3-17/32 4-3/16 2.11 * Branch Outlet Sized with Bushing TorqueSafeTM SPRINKLER HEAD TEE Gasket Sealed Brass Thread Insert Style G1 Socket x Socket x Gasket Fipt 1 r With Elastomer Seal Use NO Thread Sealant 7,- M - M2 G G2 H H2 L Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx. Wt. (Lbs.) 4202-101 G 3/43/41/2 7/16 1-3/16 7/16 1-7/16 1-7/16 1-17/32 2-29/32 1-3/8 1-3/8 1-3/8 .22 4202-124 G 10/41/2 7/16 1-11/32 9/16 1-9/16 1-11/16 1-9/16 3-1/8 1-11/16 1-3/8 1-3/8 .26 4202-130 G 1x1x1/2 7/16 1-11/32 7/16 1-9/16 1-11/16 1-9/16 3-1/8 1-23/32 1-3/8 1-23/32 .28 4202-131 G 1xlx3/4 17/32 15/16 17/32 1-11/16 1-5/8 1-11/16 3-11/32 1-23/32 1-9/16 1-23/32 .31 4202-166 G 1-1/41-1/41/2 7/16 1-5/8 7/16 1-11/16 1-15/16 1-11/16 3-3/8 2-1/16 1-3/8 2-1/16 .34 4202-209 G 1-1/2xl-1/2xl/2 1/2 1-13/16 1/2 1-7/8 2-3/32 1-7/8 3-3/4 2-11/32 1-3/8 2-11/32 .41 4202-247 G 2x2xl/2 1/2 2-1/16 1/2 2 2-11/32 2 4-1/32 2-27/32 1-3/8 2-27/32 .54 Not intended to convey or dispense water for human consumption through drinking or cooking SPEARS" MANUFACTURING COMPANY FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS El SPRINKLER HEAD TEE Brass Thread Insert Style , Socket x Socket x Fipt H1 jG M — 1 M2 G2 LG H H2 L Part Number Size G G1 G2 H I H1 I H2 L M M1 M2 Approx. Wt. 4202-010 1x1x1 1 21/31 1 1-1/8 1 21/31 1 1-25/32 1 1-29/32 1 1-25/32 1 3-19/32 1 1-23/32 1 1-23/32 1 1-23/32 1 .37 Not intended to convey or dispense water for human consumption through drinking or cooking SofTorqueTM SR REDUCING TEE Gasket Sealed Special Reinforced Plastic Thread Style Socket x Socket x SR Fipt M1 With Elastomer Seal - Use NO Thread Sealant , H1 I T M— — — — — —.—.— Mz H H22 f� L Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx. Wt. (Lbs.) 4202-101GSR 3/43/41/2 7/16 1-1/2 7/16 1-3/8 1-7/8 1-3/8 2-3/4 1-5/16 1-3/8 1-5/16 .16 4202-130GSR 1x1x1/2 7/16 1-5/8 7/16 1-1/2 2 1-1/2 3 1-5/8 1-3/8 1-5/8 .20 SPRINKLER REDUCING HEAD TEE Brass Thread Insert Style Socket x Socket x Fipt -M1—{ t i —T H1 M — - M2 G1 GH H2 2 L Part Number Size G G1 G2 H H1 H2 L M M1 I M2 Approx. Wt. (Lbs.) 4202-101 3/43/4x1/2 7116 1-1/16 7/16 1-15/32 1-5/8 1-15/32 2-29/32 1-13/32 1-3/16 1-13/32 .20 4202-124 1x3/41/2 7/16 1-11/32 9/16 1-9/16 1-11/16 1-9/16 3-1/8 1-11/16 1-3/8 1-3/8 .26 4202-130 1x1x1/2 7/16 1-7/32 7116 1-9/16 1-25/32 1-9/16 3-1/8 1-3/4 1-3/16 1-3/4 .26 4202-156 1-1/4x1x1/2 7/16 1-7/16 9/16 1-11/16 2-1/32 1-11116 3-3/8 2-3/32 1-3/16 1-23/32 .30 4202-166 1-1/4xl-1/4xl/2 7/16 1-15/32 7116 1-11/16 1 2-1/32 1-11/16 3-3/8 2-3/32 1-3/16 2-3/32 .31 4202-199 1-1/2xl-1/41/2 1/2 1-5/8 9/16 1-7/8 2-3/16 1-13/16 3-11/16 2-11132 1-3/16 2-1/16 .37 4202-209 1-101-1/202 1/2 1-5/8 1/2 1-7/8 2-3/16 1-7/8 3-3/4 2-11/32 1-3/16 2-11/32 .38 4202-237 2x1-101/2 1/2 1-27/32 17/32 2 2-7/16 1-29/32 3-15/16 2-7/8 1-3/16 2-11132 .47 4202-247 2x2xl/2 1/2 1-7/8 1/2 2 2-7/16 2 4-1/32 2-27/32 1-3/16 2-27/32 .50 Not intended to convey or dispense water for human consumption through drinking or cooking MADE IN THE U.S.A. El FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS SPRINKLER HEAD TEE Special Reinforced Plastic Thread Style Socket x Socket x SR Fipt I" L I Part Number Size G G1 G2 H H1 H2 I L I M I M1 M2 Approx. Wt. (Lbs.) 4202-010SR 1xlxl 21/32 3/4 21/32 1-25/32 1-5/8 1-25/32 3-19/32 1-23/32 1-11/16 1-23/32 .26 SPRINKLER REDUCING HEAD TEE Special Reinforced Plastic Thread Style Socket x Socket x SR Fipt �M1� f H1 MF � M2 G1 G « G2 �H-H2i L Part Number Size G G1 G2 H 1-11 H2 L M M1 M2 Approx. Wt. (Lbs.) 4202-101SR 3/43/41/2 19/32 25/32 19/32 1-19/32 1-7/16 1-19/32 3-7/32 1-13/32 1-3/16 1-13/32 .15 4202-124SR 1x3/4xl/2 7/16 29/32 9/16 1-19/32 1-5/8 1-9/16 3-5/32 1-23/32 1-3/16 1-17/32 .19 4202-130SR 1x1x1/2 7/16 29/32 7/16 1-9/16 1-5/8 1-9/16 3-1/8 1-23/32 1-3/16 1-23/32 .20 4202-156SR 1-1/4xlxl/2 15/32 1-5/32 19/32 1-23/32 1-7/8 1-23/32 3-13/32 2-3/32 1-3/16 1-23/32 .26 4202-166SR 1-1/41-1/41/2 7/16 1-1/8 7/16 1-11/16 1-27/32 1-11/16 3-3/8 2-3/32 1-3/16 2-3/32 .26 4202-168SR 1-1/41-1/41 27/32 1-1/32 27/32 2-3/32 1-29/32 2-3/32 4-7/32 2-3/32 1-11/16 2-3/32 .34 4202-199SR 1-1/2xl-1/41/2 9/16 1-9/32 17/32 1-15/16 2 1-25/32 3-23/32 2-11/32 1-3/16 2-3/32 .33 4202-209SR 1-1/2xl-1/2xl/2 1/2 1-1/4 1/2 1-7/8 1-31/32 1-7/8 3-3/4 2-11/32 1-3/16 2-11/32 .35 4202-211 SR 1-1/2xl-112xl 27/32 1-7/32 27/32 2-7/32 2-1/8 2-7/32 4-15/32 2-11/32 1-23/32 2-11/32 .44 4202-237SR 2xl-1/2xl/2 23/32 1-9/16 3/8 1 2-7/32 2-9/32 1-3/4 3-31/32 2-7/8 1-3/16 2-11/32 .45 4202-247SR 2x2x1/2 1/2 31/32 1/2 1 2 1-11/16 1 19/32 1 4 1 2-7/8 1 1-3/16 1 2-7/8 1 .48 4202-287SR 2-1/2x2-1/2xl/2 17/32 1-3/4 17/32 1 2-9/32 2-1/2 1 2-9/32 1 4-19/32 1 3-1/2 1 1-7/32 1 3-1/2 1 .78 SOFTORQU ETM SR SPRINKLER HEAD TEE I~M1� Gasket Sealed Special Reinforced Plastic Thread Style _ ___ M - 1 H, ! ____ M2 Socket x SR Fipt x Socket Stainless Steel Collar With Elastomer Seal - Use + NO Thread Sealant H �L H2' Part Number Size I G I G1 I G2 I H 1-11 H2 I L I M M1 I M2 I Approx. Wt. (Lbs.) 4203-122GSR 1xl/2x1 1 13/16 1 13/16 1 1-1/2 1 1-27/32 1 1-27/32 1 1-31/32 1 3-13/16 1 1-5/8 1-5/8 1 1-3/8 1 .22 5 SPEARS® MANUFACTURING COMPANY FlameGuar& CPVC FIRE SPRINKLER PIPING PRODUCTS TorqueSafeTM M1� SPRINKLER HEAD TEE Gasket Sealed — G1�ff I� Brass Thread Insert Style 1 + t2 _ _ _ _ Socket x Gasket Fipt x Socket With Elastomer Seal - Use NO Thread Sealant G2 �H �H2 L Part Number Size I G I G1 I G2 H H1 H2 I L M M1 M2 Approx. Wt. (Lbs.) 4203-122 G 1xl/2x1 1 19/32 1 13/16 1 1-13/32 1 1-19/32 1 1-27/32 1 1-3/4 1 3-11/32 1 1-5/8 1 1-5/8 1 1-3/8 .25 Not intended to convey or dispense water for human consumption through drinking or cooking SPRINKLER HEAD TEE M1 �I Brass Thread Insert Style Socket x Fipt x Socket G1 t HI1 1 Tr i + M — +- 2 G2 —H H2� L Part Number Size I G I G1 G2 I H H1 H2 I L M I M1 I M2 I Approx. Wt. (Lbs.) 4203-122 lxl/2x1 23/32 1 3/4 1-1/4 1 1-5/8 1-5/8 1-15/16 1 3-1/2 1 1-23/32 1 1-23/32 1 1-3/16 .25 Not intended to convey or dispense water for human consumption through drinking or cooking SPRINKLER HEAD TEE Special Reinforced Plastic Thread Style Socket x SR Fipt x Socket M1�I H1 t Tip M — M2 L L Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx. Wt. (Lbs.) 4203-122SR 1xl/2xl 27/32 23/32 1-3/32 1-23/32 1-5/8 1-25/32 3-13/32 1-3/4 1-3/4 1-3/16 .21 MADE IN THE U.S.A. 6 El FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS STREET TEE Spigot x Socket x Socket �M1� 0 of M2 f HI 1 I — —J— G1 G G2 Ham_ H2 L —: Part Number Size G G1 G2 H H1 H2 L M1 M2 Approx. Wt. (Lbs.) 4244-007 3/4 13/16 27/32 27/32 1-13/16 1-7/8 1-7/8 3-5/8 1-13/32 1-13/32 .16 4244-010 1 1-5/32 1-1/32 1-1/32 2-1/8 1-29/32 1-29/32 4-3/16 1-3/4 1-3/4 .27 4244-012 1-1/4 1-1/4 1 1 2-7/16 2-9/32 2-9/32 4-27/32 2-3/32 2-3/32 .42 4244-015 1-1/2 1-13/16 1-1/8 1-1/8 2-7/8 2-9/16 2-9/16 5-11/32 2-11/32 2-11/32 .56 4244-020 2 1-23/32 1-7/16 1-13/32 3-1/4 2-15/16 2-15/16 6-5/32 2-7/8 2-7/8 .84 900 ELBOW Socket x Socket G IF H �M� Part Number Size G H M Approx. Wt. (Lbs.) 4206-007 3/4 9/16 1-1/2 1-5/16 .07 4206-010 1 3/4 1-5/8 1-5/8 .11 4206-012 1-1/4 15/16 2-3/16 2 .22 4206-015 1-112 1-5/32 2-17/32 2-3/8 .41 4206-020 2 1-13/32 2-29/32 2-7/8 .62 4206-025 2-1/2 1-15/32 3-3/8 3-1/2 1.15 4206-030 3 1-5/32 3-3/32 4-3/16 1.83 SPEARS® MANUFACTURING COMPANY =FicameGuardO CPVC FIRE SPRINKLER PIPING PRODUCTS SIDE OUTLET ELBOW Socket x Socket x Socket M G H Part Number Size G H M Approx. Wt. (Lbs.) 4213-007 3/4 27/32 1-19/32 1-5/16 .09 4213-010 1 13/16 1-7/8 1-5/8 .18 REDUCING 900 ELBOW H1 Socket x Socket G1— G r - M1 H Part Number Size G G1 H H1 M M1 Approx. Wt. Lbs. 4206-131 1x3/4 21/32 13/16 1-25/32 1-13/16 1-19/32 1-5/16 .11 TorqueSafeTM 900 SPRINKLER HEAD ELBOW Gasket Sealed Brass Thread Insert Style Socket x Gasket Fipt With Elastomer Seal - Use NO Thread Sealant — H1 G1 G 1� M1 I 1 M, Part Number Size G G1 H H1 M M1 Approx. Wt. (Lbs.) 4207-101 G 3/41/2 9/16 1-7/32 1-13/32 1-17/32 1-13/32 1-3/8 .19 4207-130 G 1x1/2 7/16 1-3/16 1-9/16 1-11/16 1-23/32 1-3/8 .23 4207-166 G 1-1/4x1/2 15/32 1-19/32 1-15/16 1-11/16 2-3/32 1-3/8 .25 Not intended to convey or dispense water for human consumption through drinking or cooking MADE IN THE U.S.A. 8 El FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS SPRINKLER HEAD 900 ELBOW Brass Thread Insert Style H1— Socket x Fipt G t H II � Part Number Size G G1 H H1 M M1 Approx. Wt. (Lbs.) 4207-101 3/41/2 1/2 1-3/32 1-1/2 1-5/8 1-13/32 1-3/16 .17 4207-130 1x1/2 7/16 1-7/32 1-19/32 1-25/32 1-23/32 1-3/16 .21 4207-131 1x3/4 17/32 1-11/32 1-21/32 1-31/32 1-23/32 1-3/8 .25 4207-166 1-1/41/2 15/32 1-17/32 1-11/16 1-15/16 2-3/32 1-17/32 .33 Not intended to convey or dispense water for human consumption through drinking or cooking SofTorqueTM SR 900 ELBOW SPRINKLER HEAD ADAPTER Gasket Sealed Special Reinforced Plastic Thread Style Socket x SR Fipt H1 With Elastomer Seal - Use NO Thread Sealant c1 � I —— — M1 H I I I M Part Number Size G G1 H H1 M M1 Approx. Wt. (Lbs.) 4207-101GSR 3/41/2 7/16 1-17/32 1-3/8 1-27/32 1-11/32 1-3/8 .17 4207-130GSR 1x1/2 7/16 1-11/16 1-1/2 2 1-21/32 1-3/8 .19 4207-166GSR 1-1/4xl/2 7/16 1-7/8 1-11/16 2-7/32 2 1-3/8 .22 SPRINKLER HEAD 900 ELBOW Special Reinforced Plastic Thread Style —H1� Socket x SR Fipt G1 G M1 IH L I' M 'I Part Number Size G G1 H H1 M M1 Approx. Wt. (Lbs.) 4207-101SR 3141/2 11/32 13/16 1-15/32 1-1/2 1-13/32 1-3/16 .14 4207-130SR 1x1/2 7/16 7/8 1-9/16 1-5/8 1-23/32 1-3/8 .20 4207-131SR 1x3/4 1/2 7/8 1-5/8 1-9/16 1-23/32 1-3/8 .16 4207-166SR 1-1/41/2 13/32 1-1/32 1-21/32 1-23/32 2-3/32 1-7/32 .19 SPEARS® MANUFACTURING COMPANY FlameGuar& CPVC FIRE SPRINKLER PIPING PRODUCTS El 900 STREET ELBOW Spigot x Socket H1� G1 7 M1 fG H I.►� PIPE O.D. Part Number Size G G1 H H1 M1 Approx. Wt. (Lbs.) 4209-007 3/4 29/32 19/32 1-15/16 1-11/16 1-13/32 .12 4209-010 1 1-9/32 23/32 2-13/32 1-27/32 1-3/4 .21 4209-012 11-1/4 1 1-9/16 1 27/32 1 2-13/16 1 2-3/32 1 2-3/32 1 .32 4209-015 1-1/2 1-15/32 1-3/16 2-27/32 2-9/16 2-11/32 .42 4209-020 2 1-23/32 1-3/8 3-7/32 2-15/16 2-27/32 .65 22-1/20 ELBOW Socket x Socket ��lP �. M Part Number Size H J M Approx. Wt. (Lbs.) 4216-007 3/4 1-3/16 7/32 1-13/32 .09 4216-010 1 1-3/8 9/32 1-25/32 .14 4216-012 1-1/4 1-1/2 5/16 2-3/32 .20 4216-015 1-1/2 1-7/16 13/32 1-3/8 .19 4216-020 2 1-7/8 3/8 2-27/32 .43 4216-030 3 2-3/8 1/2 4-5/32 1.00 22-1/20 STREET ELBOW Spigot x Socket �— � M1 � H1 J1 H J .1-PIPE O.D. Part Number Size H H1 J J1 M1 Approx. Wt. (Lbs.) 4242-007 3/4 1-1/4 1-1/2 1/4 1/2 1-3/8 .08 4242-010 1 1-7/16 1-11/32 5/16 7/32 1-23/32 .14 4242-012 1-1/4 1-9/16 1-25/32 17/32 11/16 2-1/16 .21 4242-015 1-1/2 1-13/32 1-23/32 1/2 11/32 2-11/32 .28 4242-020 2 1-29/32 2-1/8 7/32 5/8 2-7/8 .42 4242-025 2-1/2 2-1/8 2-1/4 13/32 1/2 3-1/2 .68 4242-030 3 2-13/32 2-13/32 9/16 17/32 4-5/32 .99 MADE IN THE U.S.A. 10 El FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS 450 ELBOW Socket x Socket I H Part Number Size H J M Approx. Wt. (Lbs.) 4217-007 3/4 1-5/16 5/16 1-5/16 .07 4217-010 1 1-13/32 3/8 1-5/8 .11 4217-012 1-1/4 1-5/8 3/8 2-5/32 .21 4217-015 1-1/2 1-27/32 15/32 2-11/32 .32 4217-020 2 2-1/8 21/32 2-7/8 .48 4217-025 2-1/2 2-17/32 3/4 3-1/2 .88 4217-030 3 2-29/32 29/32 4-5/32 1.17 CROSS Socket x Socket x Socket x Socket OG1� iH1 L1 G ��� H �L-- Part Number Size G G1 H H1 L L1 M Approx. Wt. (Lbs.) 4220-007 3/4 518 5/8 1-21/32 1-21132 3-5/16 3-5/16 1-13/32 .22 4220-010 1 3/4 3/4 1-5/8 1-5/8 3-1/4 3-1/4 1-23/32 .20 4220-012 1-1/4 1-1/8 1-1/8 2-3/8 2-3/8 4-3/4 4-3/4 2-3/32 .63 4220-015 1-1/2 1-7/32 1-7/32 2-5/8 2-5/8 5-7/32 5-7/32 2-3/8 .80 4220-020 2 1-1/2 1-1/2 3 3 6 6 3 1.43 4220-025 2-1/2 1-11/16 1-11/16 3-7/16 3-7/16 6-7/8 6-7/8 3-17132 2.16 4220-030 3 2-3/32 2-3/32 3-31/32 3-31/32 7-15/16 7-15/16 4-7/16 3.37 SPEARS® MANUFACTURING COMPANY FlameGuar& CPVC FIRE SPRINKLER PIPING PRODUCTS El 450 STREET ELBOW Spigot x Socket H1 J1 M1 r H� ►I PIPE O.D. Part Number Size H Hl i ill Ml Approx. Wt. Lbs. 4227-010 1 1-1/2 1-5/16 1/2 1/4 1-5/8 .10 4227-012 1-1/4 1-25/32 1-9/16 9/16 11/32 1-31/32 .15 4227-015 1-1/2 2-1/32 2-1/8 19/32 25/32 2-11/32 .29 4227-020 2 2-5/16 1-15/16 25/32 13132 2-7/8 .44 REDUCING i.-- r-M1 Socket x Socket x Socket x Socket f H1 M - -' - L1 i • ► LPP1 ► L Part Number Size G G1 H H1 L L1 M M1 Approx. Wt. (Lbs.) 4220-131 1x3/4 23/32 5/8 1-5/8 1-5/8 3-1/4 3-1/4 1-7/8 1-1/2 .31 4220-167 1-1/43/4 1-1/16 23/32 2-1/16 1-31/32 4-3/32 3-31/32 2-1/16 1-13132 .35 4220-210 1-1/2x3/4 11/16 1-5/32 2-3/32 2-3/16 4-3/16 4-11/32 2-3/8 1-13/32 .42 4220-248 2x3/4 11/16 1-7/16 2-7/32 2-7/16 4-13/32 4-7/8 2-29/32 1-13/32 .56 4220-289 2-1/2xl 29/32 1-3/4 2-11/16 2-7/8 5-11/32 5-3/4 3-1/2 1-3/4 .98 COUPLING Socket x Socket N- M Part Number Size L M N Approx. Wt. (Lbs.) 4229-007 3/4 2-1/8 1-5/16 3/16 .05 4229-010 1 2-3/16 1-5/8 3/32 .08 4229-012 1-1/4 2-19/32 2 3/32 .13 4229-015 1-1/2 2-7/8 2-11 /32 3/32 .22 4229-020 2 3-1/8 2-7/8 1 /8 .33 4229-025 2-1/2 3-11 /16 3-15/32 3/16 .48 4229-030 3 4 4-3/16 1 /4 .89 MADE IN THE U.S.A. 12 El FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS REDUCER COUPLING Socket x Socket � 1 IM E M1 i —L N -� L Part Number Size L M M1 N Approx. Wt. (Lbs.) 4229-131 1x3/4 2-3/8 1-23/32 1-13/32 7/32 .10 4229-167 1-1/43/4 2-19/32 2-3/32 1-5/8 11/32 .17 4229-168 1-1/41 2-11/16 2-3/32 1-23/32 5/16 .18 4229-210 1-1/20/4 2-13/16 2-11/32 1-13/32 15/32 .19 4229-211 1-1/2xl 2-7/8 2-11/32 1-15/16 3/8 .24 4229-212 1-1/2xl-1/4 2-13/16 2-13/32 2-1/8 5/32 .23 4229-248 20/4 3-3/16 2-7/8 1-7/16 23/32 .32 4229-249 2x1 3-1/8 2-7/8 1-23/32 1/2 .31 4229-250 2xl-1/4 3-3/16 2-7/8 2-1/8 17/32 .33 4229-251 2xl-1/2 3-3/16 2-27/32 2-11/32 9/32 .31 4229-291 2-1/2xl-1/2 3-23/32 3-15/32 2-11/32 21/32 .51 4229-292 2-1/2x2 3-21/32 3-1/2 2-7/8 13/32 .52 4229-337 3x1-1/2 3-1/2 4-3/16 2-3/8 7/32 .71 4229-339 3x2-1/2 3-27/32 4-3/16 3-1/2 3/16 .80 GripLOCTM COUPLING - LEAD FREE w/EPDM 0-Ring Seals L 175 psi Maximum Internal Pressure @ 150°F Ar L1� WARNING: DO NOT INSERT FINGERS. Part Number Size L M1 N Approx. Wt. (Lbs.) GL4229-007 3/4 4 1-15/16 1-29/32 .25 GL4229-010 1 4-5132 2 2-1/4 .34 13 SPEARS® MANUFACTURING COMPANY FlameGuar& CPVC FIRE SPRINKLER PIPING PRODUCTS El GROOVED COUPLING ADAPTER Groove x Socket PIPE O.D. M1 1 L L Part Number Size L M1 N Approx. Wt. (Lbs.) 4233-012 1-1/4 3-5/8 2-3/32 2-11/32 .72 4233-015 1-1/2 3-3/4 2-11/32 2-11/32 .83 4233-020 2 3-27/32 2-27/32 2-11/32 1.27 4233-025 2-1/2 4-3/16 3-15/32 2-7/16 2.02 4233-030 3 4-5/16 4-1/8 2-7/16 2.76 Not intended to convey or dispense water for human consumption through drinking or cooking FEMALE ADAPTER Brass Thread Insert Style Socket x Fipt M L N M1 Part Number Size L M M1 N Approx. Wt. (Lbs.) 4235-007 3/4 2 1-13/32 1-3/8 5/16 .23 4235-010 1 2-3/16 1-3/4 1-11/16 11/32 .25 4235-012 1-1/4 2-3/8 2-3/32 2-1/16 3/8 .36 4235-015 1-1/2 2-17/32 2-3/8 2-7/16 3/8 .47 4235-020 2 2-25/32 2-27/32 3-3/16 7/16 1.05 Not intended to convey or dispense water for human consumption through drinking or cooking FEMALE ADAPTER Special Reinforced Plastic Thread Style Socket x SR Fipt M M1 1 1 N ~�~ L Part Number Size L M M1 N Approx. Wt. (Lbs.) 4235-007SR 3/4 1-7/8 1-13/32 1-3/8 3/32 .08 4235-010SR 1 2-5/32 1-23/32 1-7/8 3/32 .22 4235-012SR 1-1/4 2-5/16 2-1/8 2-1/16 3/16 .20 MADE IN THE U.S.A. 14 El FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style Socket x SR Fipt M I M1 N L� Part Number Size L M M1 N Approx. Wt. (Lbs.) 4235-101SR 3/41/2 1-29/32 1-13/32 1-3/16 1/8 .08 4235-130SR 1x1/2 1-31/32 1-23/32 1-3/8 3/32 .16 4235-131SR 1x3/4 2-3/32 1-3/4 1-3/8 1/4 .13 FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style with Socket Wrench Flats Socket x SR Fipt I M — M1 M = Flat -to -Flat Dimension N �L� Part Number Size L M M1 N Approx. Wt. (Lbs.) W4235-101SR 3/41/2 2-9/32 1-13/32 1-3/16 17/32 .09 W4235-130SR 1x1/2 2-9/32 1-3/4 1-3116 13/32 .12 15 SPEARS" MANUFACTURING COMPANY FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS El SPIGOT FEMALE ADAPTER Brass Thread Insert Style Spigot x Fipt PIPE O.D. M1 � N��► L� 1 Part Number Size L M1 N Approx. Wt. (Lbs.) 4278-007 3/4 2-5/32 1-3/8 17/32 .15 4278-010 1 2-9/32 1-11 /16 7/16 .22 Not intended to convey or dispense water for human consumption through drinking or cooking SPIGOT FEMALE ADAPTER Special Reinforced Plastic Thread Style 1 _ 1 Spigot x SR Fipt PIPE O.D. 1 M1 Part Number Size L M1 N Approx. Wt. (Lbs.) 4278-007SR 3/4 1-15/16 1-3/8 11/32 .08 4278-010SR 1 2-1/4 1-23/32 13/32 .13 TorqueSafeTm FEMALE SPRINKLER HEAD ADAPTER Gasket Sealed Brass Thread Insert Style Socket x Gasket Fipt With Elastomer Seal - Use NO Thread Sealant J M - — - —- M1 1 N—= L� Part Number Size L M M1 N Approx. Wt. (Lbs.) 4235-101 G 3/4xl/2 1-7/8 1-13/32 1-3/8 9/16 .15 4235-130GS 1 x1 /2 2-1 /32 1-11 /16 1-3/8 17/32 .17 4235-131 G 1x3/4 2 1-11/16 1-9/16 9/16 .18 Not intended to convey or dispense water for human consumption through drinking or cooking MADE IN THE U.S.A. 16 El FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS FEMALE SPRINKLER HEAD ADAPTER Brass Thread Insert Style Socket x Fipt 1 1 M M1 N �► L Part Number Size L M M1 I N Approx. Wt. (Lbs.) 4235-101 I 3/41/2 1-7/8 1-13/32 1-17/32 I 15/32 .19 4235-130 I 1x1/2 2-11/32 1-11/16 1-3/16 I 5/8 .16 4235-131 I 1 x3/4 I 2-5/16 1-11/16 1-3/8 17/32 .18 Not intended to convey or dispense water for human consumption through drinking or cooking SofTorqueTM SR FEMALE SPRINKLER HEAD ADAPTER Gasket Sealed Special Reinforced Plastic Thread Style Socket x SR Fipt With Elastomer Seal - Use NO Thread Sealant �L� M E jN--- Part Number Size L M M1 N Approx. Wt. (Lbs.) 4235-101GSR 3/41/2 2-5/16 1-5/16 1-3/8 31/32 .11 4235-130GSR 1x1/2 2-13/32 1-19/32 1-3/8 31/32 .13 4235-131GSR 104 2-13/32 1-5/8 1-23132 1 .16 QuickTorqueTM SR FEMALE SPRINKLER HEAD ADAPTER Gasket Sealed Special Reinforced Plastic Thread Style Socket x SR Metal Fipt With Elastomer Seal - Use NO Thread Sealant r ' r M ---- - lM1 Part Number Size L M M1 N Approx. Wt. (Lbs.) 4235-101GMR 3/41/2 1-15/16 1-5/16 1-9116 13/16 .17 4235-13OGMR 1x1/2 2-3/16 1-19/32 1-9/16 15/16 .19 17 SPEARS® MANUFACTURING COMPANY =FlcameGuardO CPVC FIRE SPRINKLER PIPING PRODUCTS FEMALE SPRINKLER HEAD ADAPTER Brass Thread Insert Style M 1 t�l with Long Body Socket x Fipt tJ N L Part Number Size L M M1 N Approx. Wt. (Lbs.) L4235-130 1 x1 /2 2-3/16 1-23/32 1-7/32 1 /2 .19 Not intended to convey or dispense water for human consumption through drinking or cooking FEMALE SPRINKLER HEAD ADAPTER _ Brass Thread Insert Style with Positioning Ring M M1 Socket x Fipt 1 N « L� Part Number Size L M M1 N Approx. Wt. (Lbs.) R4235-101 3/4112 2-1/32 1-7/16 1-3/16 15/32 .15 Not intended to convey or dispense water for human consumption through drinking or cooking FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style with Positioning Ring IM M1 Socket x SR Fipt N L� Part Number Size L M M1 N Approx. Wt. (Lbs.) R4235-101SR 3/41/2 1-15/16 1-7/16 1-7/32 7/32 .09 TorqueSafeTm FEMALE SPIGOT SPRINKLER HEAD ADAPTER Gasket Sealed Brass Thread Insert Style Spigot x Gasket Fipt With Elastomer Seal - Use NO Thread Sealant PIPE M1 N �► L� Part Number Size L M N Approx. Wt. (Lbs.) 4238-101 G 314xl/2 1-15/16 1-3/8 21/32 .14 4238-130 G 1x1/2 2-1/16 1-3/8 19132 .15 Not intended to convey or dispense water for human consumption through drinking or cooking MADE IN THE U.S.A. 18 El FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS SPIGOT FEMALE SPRINKLER HEAD ADAPTER Brass Thread Insert Style Spigot x Fipt 1 PIPE 11111 O.D. M1 1 N -4— I L Part Number Size L M1 N Approx. Wt. (Lbs.) 4238-101 3/4xl /2 1-15/16 1-17/32 17/32 .18 4238-130 1 x1 /2 2-1/4 1-3/16 11 /32 .19 Not intended to convey or dispense water for human consumption through drinking or cooking TorqueSafe"'I BUSHING - GASKET SEALED Brass Thread Insert Style Spigot x Gasket FIPT With Elastomer Seal - Use NO Thread Sealant PIPE _ O.D. Part Number Size L Approx. Wt. (Lbs.) 4238-130BR G 1x1/2 1-7/32 .10 Not intended to convey or dispense water for human consumption through drinking or cooking BUSHING with BRASS THREAD INSERT Spigot x Fipt j I PIPE O.D, 1 Part Number Size L Approx. Wt. (Lbs.) 4238-130BR 1 x1 /2 1 .13 Not intended to convey or dispense water for human consumption through drinking or cooking SPIGOT FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style Spigot x SR Fipt 11 PIPE O.D. N--I L� Part Number Size L M1 N Approx. Wt. (Lbs.) 4238-101SR 3/41/2 1-29/32 1-7/32 1/8 .07 4238-130SR 1 x1 /2 2-1 /32 1-7/32 7/32 .09 19 SPEARS" MANUFACTURING COMPANY FlameGuar& CPVC FIRE SPRINKLER PIPING PRODUCTS El MALE ADAPTER With CPVC Lined Thread Brass Insert Mipt x Socket — - — - — M1 — - — - IN Part Number Size L M1 N Approx. Wt. (Lbs.) 4236-007 3/4 2-17/32 1-13/32 13/16 .26 4236-010 1 2-15/16 1-23/32 29/32 .43 4236-012 1-1/4 3-1/8 2-3/32 31 /32 .66 4236-015 1-1/2 3-9/32 2-11 /32 31 /32 .80 4236-020 2 3-7/16 2-27/32 31 /32 1.00 ADJUSTABLE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style Socket x SR Fipt Q N Body �L Width Part Number Size L N Q Body Width Approx. Wt. (Lbs.) Min Max Min Max 42001SR 3/41/2 6-9/32 8 4-7/16 6-1/4 1-7/16 2-3/16 .66 42011SR 1x1/2 6-13/32 8 4-1/2 6-1/8 1-7/16 2-1/8 .68 ADJUSTABLE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style Spigot x SR Fipt PIPE Q L.D. I 1= N Body ILL Width L N Part Number Size Q Body Width Approx. Wt. (Lbs.) Min Max Min Max 42004SR 3/4x1/2 5-1/32 6-5/16 3-3/16 4-15/32 1-5/16 2-1/8 .36 42014SR 1x1/2 6-7/16 8-1/8 4-7/16 6-1/4 1-7/16 2-3/16 .67 MADE IN THE U.S.A. 20 El FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS REDUCER BUSHING Flush Style Spigot x Socket PIPE O.D. L N L Part Number Size L N Approx. Wt. (Lbs.) 4237-131 1 x3/4 1-1/4 1 /4 .04 4237-167 1-1 /4x3/4 1-7/16 7/16 .10 4237-168 1-1/41 1-13/32 9/32 .06 4237-210 1-1/20/4 1-5/8 5/8 .19 4237-211 1-1/2xl 1-17/32 13/32 .13 4237-212 1-1/2xl-1/4 1-9/16 5/16 .07 4237-248 20/4 1-29/32 29/32 .28 4237-249 2x1 1-23/32 9/16 .23 4237-250 2x1-1/4 1-11/16 7/16 .21 4237-251 2x1-1 /2 1-11 /16 5/16 .15 4237-290 2-1/2xl-1/4 2-5/32 7/8 .41 4237-291 2-1/2xl-1/2 2-5/32 3/4 .39 4237-292 2-1 /2x2 2-9/32 3/4 .28 4237-338 3x2 2-7/32 11/16 .63 4237-339 3x2-1 /2 2-5/16 1 1 /4 .42 TRANSITION BUSHING IPS Spigot x CTS Socket PIPE O.D. 1 N �L� Part Number Size L N Approx. Wt. (Lbs.) 4240-101 3/4xl/2 1 1-1/8 5/8 .03 4240-130 1 x1 /2 11-1/4 23/32 .05 CAP Socket M W Part Number Size M W Approx. Wt. (Lbs.) 4247-007 3/4 1-5/16 1-5/16 .04 4247-010 1 1-5/8 1-9/16 .06 4247-012 1-1/4 2-3/32 1-27/32 .13 4247-015 1-1/2 2-11 /32 2 .17 4247-020 2 2-27/32 2-9/32 .39 4247-025 2-1/2 3-17/32 2-5/8 .50 4247-030 3 4-3/8 3 .92 21 SPEARS® MANUFACTURING COMPANY FlameGuar& CPVC FIRE SPRINKLER PIPING PRODUCTS El TEST PLUG - 0-ring Sealed Mipt - For Pressure Testing Only, Not For use with Z4235 Series Adapters L� M1 - - - - M 1/2-14 NPT Part Number Size L M M1 Approx. Wt. (Lbs.) FTP-005 1/2 1-27/32 1-15/16 1-7/32 .03 TEST PLUG for TorqueSafeTM Gasket Sealed Head Adapters Mipt - For Pressure Testing Only. Use ONLY with Gasket Sealed Head Adapters L� M1 M 1/2 14 NPT Part Number Size L M M1 Approx. Wt. (Lbs.) FTP-005GS 1/2 1-25/32 2-1/32 1-1/4 .05 TEST PLUG (PVC White) Not UL Listed; For Pressure Testing Only, Mipt L ;I Part Number Size L Approx. Wt. (Lbs.) 4250-005 1/2 27/32 .02 MADE IN THE U.S.A. 22 El FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS FLANGE - ONE PIECE 4 Bolt Holes, 175 psi Socket M � �= � NJ BOLT CIRCLE DIA. MAX O.D. No. of Bolt Min. Bolt Max. Approx. Wt. Part Number Size L M N R Bolt Circle Bolt Size O.D. (Lbs.) Holes Dia. Len th 4251-007 3/4 1-5/32 1-1/2 1/8 17/32 4 2-3/4 1/2 2 3-29/32 .31 4251-010 1 1-5/16 1-13/16 1/8 11/16 4 3-1/8 1/2 2-1/4 4-9/32 .35 4251-012 1-1/4 1-13/32 2-7/32 5/32 11/16 4 3-1/2 1/2 2-1/4 4-5/8 .44 4251-015 1-1/2 1-19/32 2-1/2 3/16 23/32 4 3-27/32 1/2 2-1/2 5-1/16 .61 4251-020 2 1-27/32 3 5/16 27/32 4 4-3/4 5/8 3 5-31/32 .95 4251-025 2-1/2 1 2-7/32 1 3-1/2 7/16 1 1-1/32 4 5-1/2 1 5/8 1 3-1/4 7 1 1.50 BLIND FLANGE 4 Bolt Holes, 175 psi LR BOLT CIRCLE DIA. ►i MAX O.D. - Bolt No. of Bolt Min. Bolt Part Number Size R Bolt Size Max. O.D. Approx. Wt. (Lbs.) Circle Dia. Holes Length 4253-007 3/4 17/32 2-3/4 4 112 2 3-27/32 .30 4253-010 1 23/32 3-1/8 4 1/2 2-1/4 4-1/4 .35 4253-012 1-1/4 21/32 3-1/2 4 1/2 2-1/4 4-5/8 .40 4253-015 1-1/2 23/32 3-27/32 4 1/2 2-1/2 5-1/16 .52 4253-020 2 27/32 4-3/4 4 5/8 3 5-31132 .86 4253-025 1 2-1/2 1-1/32 1 5-1/2 1 4 5/8 1 3-1/4 1 6-15/16 1 1.70 4253-030 1 3 1 1-5/16 1 6 1 4 1 5/8 1 3-1/4 1 7-5/8 1 1.72 FLANGE - TWO PIECE Van Stone Style, 4 Bolt Holes, 175 psi Socket M L R N-# BOLT CIRCLE DIA. �I MAX O.D. Bolt Circle No. of Bolt Min. Bolt Part Number Size L M N R Dia. Holes Bolt Size Length Max. O.D. Approx. Wt. (Lbs.) 4254-030 3 2-1/8 1 4-1/4 1 9/32 1 1-1/32 6 4 1 5/8 1 3-1/4 1 7-15/32 1 1.75 23 SPEARS® MANUFACTURING COMPANY FlameGuar& CPVC FIRE SPRINKLER PIPING PRODUCTS El FLANGE - TWO PIECE Van Stone Style, 4 Bolt Holes, 175 psi 11- PIPE O.D. Spigot N L R BOLT CIRCLE6DIA-0-1 MAX O.D. Bolt No. of Bolt Min. Bolt Approx. Wt. Part Number Size L N R Bolt Size Max. O.D. Circle Dia. Holes Length (Lbs.) 4256-007 3/4 1-15/16 13/16 17/32 2-3/4 4 1/2 2 3-27/32 .30 4256-010 1 2-7/32 1-1/32 11/16 3-1/8 4 1/2 2-1/4 4-1/4 .41 4256-012 1-1/4 2-3/8 1 11/16 3-1/2 4 1/2 2-1/4 4-5/8 .50 4256-015 1-1/2 2-7/16 1-3/32 23/32 3-7/8 4 1/2 2-1/2 4-31/32 .65 4256-020 2 2-3/4 1-5/32 25/32 4-3/4 4 5/8 3 5-15/16 1.00 4256-025 2-1/2 3-1/16 1-9/32 1-1/32 5-1/2 4 5/8 3-1/4 6-15/16 1.62 4256-030 3 3-3/8 1-13/32 1-1/32 6 4 5/8 3-1/4 7-9/16 1.76 TRANSITION UNION Brass Thread Insert Style Socket x Fipt 175 psi NUT M _ O.D. L L N Part Number Size L M N Nut O.D. Approx. Wt. (Lbs.) 4259-010BR 1 2-13/16 1-7/8 1-1/32 2-7/8 .52 4259-012BR 1-1/4 3 2-3/16 1-1/8 3-9/32 .98 4259-015BR 1-1/2 3-3/4 2-1/2 1-9/16 3-17/32 .93 4259-020BR 2 3-5/8 2-7/8 1-1/4 4-5/16 1.64 Not intended to convey or dispense water for human consumption through drinking or cooking UNION Socket x Socket 175 psi NUT M O.D. N L Part Number Size L M N Nut O.D. Approx. Wt. (Lbs.) 4257-007 3/4 2-3/8 1-17/32 3/8 2-1/2 .38 4257-010 1 2-9/16 1-27/32 3/8 2-7/8 .41 4257-012 1-1/4 2-27/32 2-7/32 11/32 3-5/16 .52 4257-015 1-1/2 3-1/8 2-1/2 3/8 3-17/32 .63 4257-020 2 3-5/8 3-1/32 9/16 4-3/16 1.09 MADE IN THE U.S.A. 24 El FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS SofforqueTM SR FEMALE SPIGOT SPRINKLER HEAD ADAPTER Gasket Sealed Special Reinforced Plastic Thread Style Spigot x SR Fipt With Elastomer Seal - Use NO Thread Sealant PIPE O.D. -- M1 N Part Number Size L M1 N Approx. Wt. (Lbs.) 4278-101GSR 3/4x1/2 2-1/4 1-3/8 1 .11 SHORT REPAIR COUPLING Spigot x Socket 175 psi L2 �L1- L3 I *-S Part Number Size L1 L2 L3 M S Approx. Wt. (Lbs.) SH118-07CO 3/4 4-13/16 5-17/32 3/4 1-3/4 2-3/16 .31 SH118-1000 1 4-3/4 5-5/8 31/32 2-1/16 2-5/32 .40 GripLocTM REPAIR COUPLING — LEAD FREE w/EPDM 0-Ring Seals WARNING: DO NOT INSERT FINGERS. 175 psi Maximum Pressure @ 150°F Part Number Size L L1 L2 M S Approx. Wt. Lbs. SG118-1000 1 1-17/32 7-17/32 4-1/4 2-1/4 2-27/32 .73 25 SPEARS" MANUFACTURING COMPANY FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS FlameGuard° CPVC Drain & Swing Check Valves for NFPA 13D Applications Only El Application: FlameGuard° CPVC Orange Swing Check Valves and PVC/CPVC True Union Drain Valves are for use in configuring CPVC Fire Sprinkler System connection to water supply (riser/drain assembly) in NFPA 13D installations only. These valves are not UL Listed and NOT for use in any other locations within the fire sprinkler system. TRUE UNION INDUSTRIAL DRAIN VALVES CPVC Gray Valve with CPVC Orange End Connector Socket x Socket E I I D I 1 A B C Part Number Size A B c D E 1822-007CFG 3/4 2-1/4 2-3/4 4-3/4 2-7/8 3-3/8 1822-010CFG 1 2-1/2 2-7/8 5-1/8 3-1/8 3-7/16 1822-012CFG 1-1/4 3-1/16 3-1/4 5-3/4 3-5/8 3-7/8 1822-015CFG 1-1/2 3-1/2 3-1/2 6-1/4 4 4-3/16 1822-020CFG 2 4-1/4 4-3/4 7-3/4 4-1/2 5-1/8 Not UL Listed TRUE UNION DRAIN VALVES PVC Valve with CPVC End Connector Socket x Socket WED A — — l B� C— Part Number Size A B c D E 3622-007FG 3/4 2-1/4 2-3/4 4-3/4 2 3 3622-010FG 1 2-1/2 2-7/8 5-1/8 2-5/16 3-7/16 Not UL Listed MADE IN THE U.S.A. 26 El FlameGuard® CPVC FIRE SPRINKLER PIPING PRODUCTS COMPACT 2000 DRAIN VALVE = E Socket x Socket D A — — — — — �B� c Part Number Size A B C D E 6622-007C0 3/4 1-13/16 1-1/2 3-9/16 2 3 6622-01000 1 2-1 /16 1-3/4 4 2-5/16 3-7/16 Not UL Listed CPVC SWING CHECK VALVES Socket x Socket A -- D B k C 10 Part Number Size A B C D Approx. Wt. (Lbs) S1520-1000 1 1-11/16 2-5/16 4-9/16 2-5/8 .33 S1520-12C0 1-1/4 2-1/16 2-15/16 5-1/2 3-3/8 .42 S1520-15C 1 1-1/2 1 2-7/16 13 15-5/8 13-3/8 1.89 Not UL Listed CPVC SPECIAL REINFORCED THREAD INLET SWING CHECK VALVES SR Fipt x Socket A WB-O— — — D 1 14 C Part Number Size A B C D Approx. Wt. (Lbs) S1520-10FSRSCO 1 1-11/16 2-15/16 4-9/16 2-5/8 .33 S1520-12FSRSCO 1-1/4 2-1/16 3-5/8 5-1/2 3-3/8 .42 S1520-15FSRSCO 1-1/2 2-7/16 3-11/16 5-5/8 3-3/8 .89 Not UL Listed 27 SPEARS® MANUFACTURING COMPANY NOTES NOTES PRODUCT LIMITED LIFETIME WARRANTY El Except as otherwise specified for certain products, mandated by law or herein provided, Spears" Manufacturing Company ("Company') warrants Standard Catalog Products ("Products") which have been directly manufactured by them to be free from defects in material and workmanship for as long as the original intended end user of the Products ("End User") retains ownership and possession of the Products and complies with this Warranty ("Warranty Period"). Each other person or entity acquiring or employing the Products, including buyers, contractors and installers ("Buyer") and End Users ('Buyer/End User") agrees that this Warranty shall be effective only during the Warranty Period so long as the Products are used solely for the normal purposes for which they are intended and in conformance with industry established standards, engineering, installation, operating, and maintenance specifications, recommendations and instructions including explicit instructions by the Company; the Products are properly installed, operated and used, and have not been modified; and all the other terms of this Warranty are complied with. Any violation thereof shall void this Warranty and relieve Company from all obligations arising from this Warranty and the Products. Upon receipt or discovery of any Products that appear questionable or defective each Buyer/End User shall promptly inspect and return any such Prod- uct to the Company at 15853 Olden Street, Sylmar, California 91342, accompanied by a letter stating the nature of any problems. If the Prod- ucts are determined by Company to be defective in materials or workmanship directly provided by Company, Company, at its sole option, may ei- ther repair or replace the defective Products, or reimburse applicable Buyer/End User for the cost of such Products. The applicable Buyer/End User shall bear all applicable shipping costs. THIS SHALL BE BUYERS/END USERS' SOLE REMEDY. EACH BUYER/END USER AGREES THAT COMPANY WILL NOT BE RESPONSIBLE FOR ANY OTHER OBLIGATIONS RELATING TO THE PRODUCTS, INCLUDING ANY OTH- ER MATERIALS OR LABOR COSTS, LOSS OF USE OR ANY OTHER ITEM OR FOR ANY DELAYS IN COMPLYING WITH THIS WARRANTY BEYOND COMPANY'S REASONABLE CONTROL. COMPANY SHALL NOT BE LIABLE FOR, DOES NOT ASSUME, AND EXPRESSLY DISCLAIMS, ANY LIABILITY, RESPONSIBILITY AND DAMAGES: DUE TO ANY BUYER/END USER'S FAILURE TO COMPLY WITH THIS WARRANTY, INCLUDING IMPROPER INSTALLATION, USE OR OPERATION; USE WITH PRODUCTS FROM OTHER MANUFACTURERS THAT DO NOT MEET ASTM OR OTHER APPLICABLE PRODUCT STANDARDS; IMPROPER CONTROL OF SYSTEM HYDRAULICS, IMPROPER WINTERIZATION PROCEDURES, IMPROPER VOLTAGE SUPPLY, CON- TACT WITH INCOMPATIBLE MATERIALS OR CHEMICALS, EXCAVATION/DIGGING, EXCESSIVE WEIGHT, AND VANDALISM; DUE TO REASONABLE WEARAND TEARAND DUE TOANYACTS OF NATURE, INCLUDING LIGHTNING, EARTHQUAKES, GROUND MOVEMENT, FROST HEAVE, OR FLOODS. COMPANY EXTENDS ONLYTHIS WARRANTYAND EXPLICITLY DISCLAIMSALL OTHER WARRANTIES, WHETHER IMPLIED OR OTHERWISE EXPRESSED, WHETHER ORAL, STATUTORY OR OTHERWISE, INCLUDING ANY IMPLIED WARRANTIES OR AFFIRMATIONS FOR SUITABILITY, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. NO AFFIRMATION BY COMPANY OR ANY OF ITS REPRESENTATIVES, BY WORDS, CONDUCT OR OTHERWISE, SHALL CONSTITUTE A WARRANTY. THIS WARRANTY MAY NOT BE TRANSFERRED, EXTENDED, ALTERED OR OTHERWISE MODIFIED IN ANY MANNER, EXCEPT BY WRITTEN AGREEMENT SIGNED BY COMPANY. BY ITS ACCEPTANCE OF THE PRODUCTS, EACH BUYER/END USER EXPRESSLY WAIVES ALL OTHER LIABILITY OR OBLIGATION OF ANY KIND OR CHARACTER OF COMPANY, INCLUDING LIABILITY PREDICATED UPON CONTRACT, TORT, STRICT LIABILITY OR OTHER LEGAL OR EQUITABLE GROUNDS, AND ALL, IF ANY, DAMAGES AND LOSSES AS A RESULT THEREOF, INCLUDING ALL, IF ANY, COMPENSATORY, GENERAL, SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR PUNITIVE DAMAGES. WITH RESPECT TO SUCH WAIVERS, EACH BUYER/END USER EXPLICITLY WAIVES CALIFORNIA CIVIL CODE §1542 WHICH STATES "A GENERAL RELEASE DOES NOT EXTEND TO CLAIMS WHICH THE CREDITOR DOES NOT KNOW OR SUSPECT TO EXIST IN HIS FAVOR AT THE TIME OF EXECUTING THIS RELEASE, WHICH IF KNOWN BY HIM MUST HAVE MATERIALLY ADVERSELY AFFECTED HIS SETTLEMENT WITH DEBTOR" AND ALL OTHER SIMILAR STATU- TORY, COMMON AND CASE LAW RIGHTS, DEFENSES AND LIMITATIONS. Having previously independently inspected the Products, or a sample, as fully as desired, or having the opportunity to and having not done so, upon acceptance of delivery of the Products, and except as otherwise herein explicitly provided, each Buyer/End User by acceptance or use of the Products accepts them in their "AS IS" and "WITH ALL FAULTS" condition without any other warranty, expressed, implied or otherwise, and accepts and assumes the entire risk and cost of all servicing, remediation and consequences thereof. This Warranty shall be governed by California law and any unenforceable provisions severed without affecting the remaining provisions. As used herein, "including" includes "without limitation." Spears° Quality Policy It is the policy and objective of Spears® Manufacturing Company to produce a superior quality product suitable for its intended use, with regard to functionality, structural integrity and conformance to established industry standards and practices. It is the commitment of this Company to do so in a manner which provides consistency of product quality, optimum availability, and superior customer service, while maintaining efficiency of operations and profitability necessary to perpetuate product improvement and customer satisfaction. Furthermore, it is recognized that the attainment of these objectives is the responsibility of all Company operations and personnel according to their respective functions. The information contained in this publication is based on current information and product design at the time of publication and is subject to change without notification. Our ongoing commitment to product improvement may result in some variations. No representations, guarantees or warranties of any kind are made as to its accuracy, suitability for particular application or results to be obtained therefrom. For information not contained herein, please contact Spears® Technical Services Department [West Coast: (818) 364-1611— East Coast: (678) 985-1263]. Reproduction of this publication in whole or in part is prohibited without the authorized consent of Spears® Manufacturing Company, Sylmar, California. © Copyright 2014 Spears® Manufacturing Company. All Rights Reserved. Printed in the United States of America. SPEARS° MANUFACTURING COMPANY Corporate Office SPEARS 15853 Olden Street • Sylmar, CA 91342 PO Box 9203 • Sylmar, CA 91392 1] (818) 364-1611 • http://www.spearsmfg.com © Copyright 2015 Spears® Manufacturing Company. All Rights Reserved. Printed in the United States of America 11/15. FG-4-1115 Hangers & Sway Bracing Fig. 187 (Formerly Afton Fig. 511) TWo Hole 90' Side Mount Strap U Size Range: 3/4' through 2" Finish: Zinc Plated Steel (Hot -Dip Galvanized optional) Service: Hanger for CPVC pipe in the horizontal position on the bottom of structural wood beams and Steel 20 Ga. (min.) (Fig. A). Can be used as a restrainer, only in Stee120 Ga. (min) (Fig. B). During installation, adjust hanger mounting flanges such that pipe contacts both mounting surface and hanger, minimizing vertical pipe movement. Approvals: UL and ULC Listed. Installation: • Snap hanger over pipe. • Secure hanger to mounting surface with screws provided. • Do not anchor tightly to mounting surface. Pipe must be allowed to move freely through hanger. • Steel applications require two (2) #14 x 1" hex washer head self -drilling TEK screws. Not Supplied. Part Number STD-0090. Features: • Beveled edge design helps protect the CPVC pipe from any rough surface. • Easily attaches to wood structure with #10 x 1" hex washer head self threading screw supplied with product. No pre -drilling required. Ordering: Specify CPVC pipe size, figure number and description. Fig. A c &us LISTED Fig. B FIG. 187: DIMENSIONS (IN) • WEIGHT (LBS) CPVC Pipe Size A B oC E F Max. Hanger Spacing (FT.) Approx. Weight/100 (lbs) a/4 1 11/2 1/4 11/a 2a/4 51/2 5 1 1 1/a 1 1/2 1/a 1 1/a 21 a/16 6 6 11/a 1'/1s 11 a/a 11/a 111/a 131/a 1 61/z 1 7 1 1/2 1 1/2 1 '/a 1/4 1 1A 31/2 7 8 2 1 a/a 2 1/a 11A 3% 8 9 0Z ANVIL PH-1.18 Fig. 188R (Formerly Afcon Fig. 514) Size Range:'/a" through 2" Material: Carbon Steel Finish: Pre -Galvanized per ASTM A653 Service: TWo Hole Standoff and Restrainer • Hanger and surge restraint for horizontal CPVC piping when installed on the top, bot- tom, and side of the supporting structure. • Guide for vertical CPVC piping when installed on the side of the supporting structure. • Horizontal and vertical seismic restraint per NFPA 13-2016 requirements. • Listed with hardware provided on structural wood beams and composite wood beams (1" minimum). Listed with steel (18ga minimum) with two (2) #141" or'/a"xl" hex washer head self -drilling TEK screws. For wood structures with less than 1" thickness, wood blocks may be placed on the backside of the wood structure. #10xl" fastener provided must be fully engaged in the wood block. • May be installed with concrete, steel structural members, and other structural members with fasteners which comply with the requirements of NFPA 13. Approvals: cULus Listed Patents: No. 6,648,278 Installation: • Snap hanger over pipe. If needed, squeeze strap back around pipe. • CPVC pipe must be allowed to slide freely through the Fig.188R. • Secure hanger to mounting surface with screws provided or with listed fasteners. Features: • Beveled edge design helps protect the CPVC pipe from any rough surface and eliminates pipe abrasion. • Easily attaches to wood structure with #10 x 1" hex washer head self -threading screw supplied with product. No pre -drilling required. • Bottom of pipe is offset 1'/2" from the structure. Eliminates wooden spacer blocks. Ordering: Specify CPVC pipe size, figure number and description. Hanger & Restrainer Hange Restra a& ainer C &us LISTED Installation - Backing Nut Hanger =1 - at top fastener Restraint = 2 - on each fastener Per NFPA-13D and NFPA-13R 0Z ANVIL PH-1.18 III CPVC III Fig. 188R (Formerly Afcon Fig. 514) 7Wo Hole Standoff and Restrainer (cons.) B A E O+ + Oc Hanger and Restrainer FIG.188R: DIMENSIONS (IN) a WEIGHT (LBS) CPVC Pipe Size A B �C D E F G Max. Hanger Spacing (FT.) Approx. Weight/100 (Ibs) % 2% 3'/2 '/4 2 1 2% 1'/2 5'/2 11 1 2' 3/ 6 3'/2 '/4 23/ 6 1 2' S/ 6 1'/2 6 12 1'/4 2' 3/ 6 3'/2 '/4 2'/16 1 3'/4 1'/2 6'/2 13 1'/2 3% 4'/4 '/4 2'/16 1 3'/2 1'/2 7 14 2 3" /s 4% '/4 2" /s 1 4 1'/2 8 16 Z ANVIL PH-1.18 Fig. 29 - Double Offset Hanger & Restrainer for CPVC Plastic Pipe & IPS Steel Pipe** Size Range: Available in 3/4" (20mm) and 1 " (25mm) pipe sizes Material: Pre -Galvanized Steel Function: Intended to perform as a hanger and restrainer for CPVC, plastic fire sprinkler pipe. Provides double offset 11/2" (20mm) x 11/2" (2omm) from mounting surface. This design will ease installation by eliminating the need for wood block extension and allow retro-fit attachment of hanger to sprinkler pipe. Features: • Thumb tab provides protection to restrain pipe in rough job site conditions. Tab is not required to be bent for listed installation. • Offset edge eliminates abrasion. • Attaches easily to wood structure with two special #10 x 1" hex head self -threading screws furnished with product. • Can be used as a single offset hanger by aligning "dimples" with top of mounting surface and utilizing two fasteners in two of the three holes provided. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) as a hanger and restrainer to support fire sprinkler systems. Meets and exceeds requirements of NFPA 13, 13R and 13D. Finish: Pre -Galvanized Order By: Figure number and pipe size. Patent Pending "" With reduced spacing, consult factory. Double Offset Single Offset (38.1 mm) �O 00 0 No 0 0 0 O C 1.5" (38.1mm) (bTOLCC' C&US LISTED Install using a rechargeable electric drill fitted with a 5/16" (7.9mm) socket attachment with the special hex head self -tapping screws provided. Install screws until they bottom out. Pipe can be "snapped" into hanger before or after installation of the screws to the mounting surface. "Thumb tab" may be bent up to provide additional protection to the pipe, but is not required for performance of the hanger / restrainer function. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. PW COOPER B-Line Valves & Accessories ES-A-200013 Job Name Contractor Job Location Approval Engineer Contractor's P.O. No. Approval Series 2000B Double Check Valve Assemblies Sizes: 1/2" - 2" Series 2000B Double Check Valve Assemblies are designed to protect drinking water supplies for dangerous cross -connections in accordance with national plumbing codes and water authority requirements for non -health -hazard non -potable service applica- tions such as irrigation, fire line, or industrial processing. These valves meet the requirements of ASSE Std. 1015 and AWWA Std. C510 and are approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. Features • Ease of maintenance with only one cover • Top entry • Replaceable seats and seat discs • Modular construction • Compact design •'/2" — 2" Cast bronze body construction • Top mounted ball valve test cocks • Low pressure drop • No special tools required •'/2" — 1 " have tee handles WAT111,11. It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material product, consult your local water author- ity, building and plumbing codes. Representative 3/4" 2000B (20mm) 1 —5 2" 2000B HC (50mm) Specifications A Double Check Valve Assembly shall be installed at each not- ed location. The assembly shall consist of two positive seating check modules with captured springs and rubber seat discs. The check module seats and seat discs shall be replaceable. Service of all internal components shall be through a single access cover secured with stainless steel bolts. The assembly shall also include two resilient seated isolation valves and four top mounted, resilient seated test cocks. The assembly shall meet the requirements of ASSE Std. 1015 and AWWA Std. C510. Approved by the Foundation for Cross - Connection Control and Hydraulic Research at the University of Southern California. Assembly shall be an Ames Fire & Waterworks Series 2000B. The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. Ames Fire & Waterworks product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measure- ments, please contact Ames Fire & Waterworks Technical Service. Ames Fire & Waterworks reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames Fire & Waterworks products previously or subsequently sold. A WATTS Brand Available Models Suffix: B - Quarter turn ball valves LBV - less ball valves SH - stainless steel ball valve handles HC - 21/2" inlet/outlet fire hydrant fitting (2" valve) Pressure — Temperature Temperature Range: 33°F — 140°F (0.5°C — 60°C) Maximum Working Pressure: 175psi (12.1 bar) Dimensions - Weights Standards AWWA Std. C510, IAPMO PS31 4:3AssiFje Approvals Gc U P� o c QL us us 1015 B64.5 3/4" - 2" (LBV Models Only) • Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. (Excluding all LBV Models) • Horizontal and vertical "flow up" approval on all sizes. Suffix HC — Fire Hydrant Fittings dimension "A" = 231/2" (594mm) SIZE DIMENSIONS WEIGHT in. in. A mm in. B mm in. C mm in. F mm G in. mm H in. mm I in. mm lbs. kgs. 1/2 10 254 4% 117 27/16 62 5 127 3% 85 25/116 59 21/16 52 4.5 2 3/4 111/8 282 4 102 31/8 79 63/s 157 3'/16 87 21/8 54 15/16 33 5 2.3 1 131/4 337 5% 130 4 102 71/2 191 3% 85 111/16 43 111/16 43 12 5.4 11/4 16% 416 5 127 V16 84 91/2 241 5 127 3 76 2 50 15 6.8 11/2 1 163/4 425 1 47/a 124 31/2 89 1 93/4 248 1 513/16 148 1 31/8 79 1 211/6 68 15.86 7.2 2 1 191/2 495 1 61/4 159 1 4 102 1 13% 340 1 61/6 156 1 3'/6 87 1 211/8 68 1 25.75 11.7 Strainer sold separately Capacities As compiled from documented Foundation for Cross - Connection Control and Hydraulic Research at the University of Southern California lab tests. ATypical maximum system flow rate (7.5 feet/sec., 2.3 meters/sec.) kPa psi 11211 A y 83 12 0 69 10 (D 55 8 7 41 6 N 28 4 N 14 2 n 0 0 0 2 4 6 8 10 12 gpm AP 0 7.6 15.2 22.8 30.4 38 45.6 Ipm 5 7.5 10 fps 1.5 2.3 3.0 mps Flow Rate kPa psi H 152 22 0 124 18 96 14 0 H 69 10 . 41 6 a 14 2 31.11 kPa psi 96 14 N 83 12 o 69 10 y 55 8 41 6 y 28 4 L 14 2 0 0 41/wn AP 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate kPa psi � 1112 83 12 N 69 10 0 55 8 y 41 6 7 28 4 N 14 2 i 0 0 L pp0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate AP 0 5 10 15 26 25 30 35 40 45 50 gpm 0 19 38 57 76 95 114 133 152 171 190 Ipm 7.5 15 fps 2.3 4.6 mps Flow Rate kPa psi y 110 16 0 83 12 y 69 10 3 55 8 N 41 6 28 4 a 14 2 0 5 10 15 20 25 30 35 40 45 50 55 60 gp AP 0 19 38 57 76 95 114 133 152 171 190 209 228 Ip 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate A WATTS Brand ES-A-2000B 1735 kPa psi J a m 211 N 83 12 p 69 10 55 8 41 6 3 N 28 4 i 14 2 0 0 0 25 50 75 100 125 150 175 200 gpm DP 0 95 190 285 380 475 570 665 760 Ipm m 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate USA: Backflow T: (978) 689-6066 • F: (978) 975-8350 • AmesFireWater.com USA: Control Valves T: (713) 943-0688 • F: (713) 944-9445 • AmesFireWater.com Canada: T: (905) 332-4090 • F: (905) 332-7068 • AmesFireWater.ca Latin America: T: (52) 81-1001-8600 • AmesFireWater.com © 2017 Ames Fire & Waterworks Alarms & Supervisory Devices CrPOTTER The Symbol of Protection Specifications subject to change without notice. Ordering Information Nominal Pipe Size Model Part Number 2" DN50 VSR-2 1144402 21/2" DN65 VSR-2 1/2 1144425 3" DN80 VSR-3 1144403 3 1/2" VSR-3 1/2 1144435 4" DN100 VSR-4 1144404 5" VSR-5 1144405 6" DN150 VSR-6 1144406 8" DN200 VSR-8 1144408 Optional: Cover Tamper Switch Kit, stock no. 0090148 Replaceable Components: Retard/Switch Assembly, stock no. 1029030 VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD UL, CUL and CSFM Listed, FM Approved, LPCBApproved, For CE Marked (EN12259-5) / VdSApproved model use VSR-EU Service Pressure: 450 PSI (31 BAR) - UL Flow Sensitivity Range for Signal: 4-10 GPM (15-38 LPM) -UL Maximum Surge: 18 FPS (5.5 m/s) Contact Ratings: Two sets of SPDT (Form C) 10.0Amps at 125/250VAC 2.0 Amps at 30VDC Resistive 10 mAmps min. at 24VDC Conduit Entrances: Two knockouts provided for 1/2" conduit. Individual switch compartments suitable for dissimilar voltages. Environmental Specifications: • NEMA 4/IP54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fitting. • Temperature Range: 40°F - 120°F, (4.5°C - 49°C) - UL • Non -corrosive sleeve factory installed in saddle. Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 • Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. • Shock hazard. Disconnect power source before servicing. Serious injury or death could result. • Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. CAUTION Waterflow switches that are monitoring wet pipe sprinkler systems shall not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterflow switches used for this application may result in unintended discharges caused by surges, trapped air, or short retard times. Important: This document contains important information on the installation and operation of the VSR waterflow switches. Please read all instructions carefully before beginning installation. A copy of this document is required by NFPA 72 to be maintained on site. General Information Enclosure The Model VSR is a vane type waterflow switch for use on wet sprinkler The VSR switches and retard device are enclosed in a general purpose, systems. It is UL Listed for use on a steel pipe; schedules 5 through 40, die-cast housing. The cover is held in place with two tamper resistant sizes 2" - 6" and is UL Listed and FM Approved for use on steel pipe; screws which require a special key for removal. A field installable schedules 10 through 40, sizes 2" thm 8" (50 mm thm 200 mm). LPC cover tamper switch is available as an option which may be used approved sizes are 2" thru 8" (50 mm thru 200 mm). See Ordering to indicate unauthorized removal of the cover. See bulletin number Information chart. 5401103 for installation instructions of this switch. The VSR may also be used as a sectional waterflow detector on large systems. The VSR contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 GPM (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-1211/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG. #5401146 - REV M PAGE 1 OF 4 11115 (E)POTTER The Symbol of Protection VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Installation (see Fig. 1) These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they shall be installed on the top side of the pipe where they will be accessible. The device should not be installed within 6" (15 cm) of a fitting which changes the direction of the waterflow or within 24" (60 cm) of a valve or drain. NOTE: Do not leave cover off for an extended period of time. Drain the system and drill a hole in the pipe using a hole saw in a slow speed drill (see Fig. 1). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterflow. Take care not to damage the non -corrosive bushing in the saddle. The bushing should fit inside the hole in the pipe. Install the saddle strap and tighten nuts alternately to required torque (see the chart in Fig. 1). The vane must not rub the inside of the pipe or bind in any way. A CAUTION Do not trim the paddle. Failure to follow these instructions may prevent the device from operating and will void the warranty. Do not obstruct or otherwise prevent the trip stem of the flow switch from moving when water flows as this could damage the flow switch and prevent an alarm. If an alarm is not desired, a qualified technician should disable the alarm system. Fig. 1 Retard Adjustment DO NOT LEAVE COVER OFF FOR aNEXTENDED PER7oDOFTIME The delay can be adjusted by rotating the retard adjustment knob from 0 to the max setting (60-90 seconds). The time delay should be set at the minimum required to prevent false alarms DIRECTION OF WATERFLOW TIGHTEN NUTS ALTERNATELY O MOUNT ON PIPE SO ARROW ON SADDLE POINTS IN DIRECTION l \ OF WATERFLOW CAUTION Hole must be drilled perpendicular to the pipe and vertically centered. Refer to the Compatible Pipe/Installation Requirements chart for size. Correct Incorrect I -E��- _E7�_ ROLL PADDLE IN OPPOSITE DIRECTION OF WATERFLOW (Flowing water activates device in one direction only) DWG t146-1t 50- ADAPTER ADAPTER 20-+2= MAX. DN50 ONLY USE (2) 5180162 ADAPTERS AS SHOWN ABOVE DWG# 1146-IF Compatible Pipe/ Installation Requirements Model Nominal Pipe Size Nominal Pipe O.D. Pipe Wall Thickness Hole Size U-Bolt Nuts Torque Lightwall Schedule 10 (iIL) Schedule 40 (UL) BS-1387 (LPC) DN (VDS) inch mm inch mm inch mm inch mm inch mm inch mm inch min inch mm ft-lb n-m VSR-2 2 DN50 2.375 60.3 .065 1.651 0.109 2.77 0.154 3.91 0.142 3.6 0.091 2.3 1.25 +.125/- 062 33.0 2.0 VSR-21/2 2.5 2.875 73.0 .084 2.134 0.120 3.05 0.203 5.16 - - - - VSR-21/2 - DN65 3.000 76.1 - - - - - - 0.142 3.6 0.102 2.6 VSR-3 3 DN80 3.500 88.9 .083 2.108 0.120 3.05 0.216 5.49 0.157 4.0 0.114 2.9 2.00±.125 50.8t2.0 20 27 VSR-31/2 3.5 - 4.000 101.6 - - 0.120 3.05 0.226 5.74 - - - - VSR-4 4 DN100 4.500 114.3 .084 2.134 0.120 3.05 0.237 6.02 0.177 4.5 0.126 3.2 VSR-5 5 - 5.563 141.3 - - 0.134 3.40 0.258 6.55 - - - - VSR-6 6 DN150 6.625 168.3 .115 2.921 0.134 3.40 0.280 7.11 0.197 5.0 0.157 4.0 VSR-8 8 DN200 8.625 219.1 - - 0.148 1 3.76 1 0.322 8.18 0.248 1 6.3 1 0.177 1 4.5 NOTE: For copper or plastic pipe use Model VSR-CF. PRINTED IN USA MFG. #5401146 - REV M PAGE 2 OF 4 11115 CF�)POTTER The Symbol of Protection Fig. 2 To remove knockouts: Place screwdriver at inside edge of knockouts, not in the center. Do not drill into the base as this creates metal shavings which can create electrical hazards and damage the device. Drilling voids the warranty. Fig. 3 Break out thin section of cover when wiring both switches from one conduit entrance. Fig. 5 Typical Electrical Connections Notes: 1. The Model VSR has two switches, one can be used to operate a central station, proprietary or remote signaling unit, while the other contact is used to operate a local audible or visual annunciator. 2. For supervised circuits, see "Switch Terminal Connections" drawing and warning note (Fig. 4). rasa VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Fig. 4 Switch Terminal Connections Clamping Plate Terminal � % I�CO�Ilj6 1 �0�6 �� DWG. #1146-16 AWATNING M An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device inoperable risking severe property damage and loss of life. Do not strip wire beyond 3/8" of length or expose an uninsulated conductor beyond the edge of the terminal block. When using stranded wire, capture all strands under the clamping plate. NEUTRAL FROM BREAKER NEUTRAL FROM BELL 1 BREAKER J LINE FROM BREAKER EOL (End Of Line Resistor) NOTE: When connecting to a UL Listed control panel, use the panel's resistor value for circuit supervision. Testing The frequency of inspection and testing for the Model VSR and its associated protective monitoring system shall be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector's test valve shall always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR is not recommended or advisable. A minimum flow of 10 GPM (38 LPM) is required to activate this device. Advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. Fig. 6 Mounting Dimensions 5.56 in Fig. 7 3.50 in (141.2 mtn) 2.00 in r (89.0 —)y (50.8 mm) GREEN GROUND SCREWS 2.34 in (59.4 —) PI E DIA. U-BOLT NUT + 5.25 in U-BOLT WASHER (+ 33.4 —) PIPE SADDLE 4 4�- PIPE t t PLASTIC PADDLE---'® Q DWG. 11d8-id U-BOLT NOMINAL PIPE DIA. +1.75 in (+44.5 MM) FOR DN 50 — DN 65 2-2.5 in NOMINAL PIPE DIA. +2.125 in (+54.0 MM) FOR DN 80 — DN 200 3-8 in OWG 1146-15 PRINTED IN USA MFG. #5401146 - REV M PAGE 3 OF 4 11115 (E)POTTER The Symbol of Protection VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Maintenance Inspect detectors monthly. If leaks are found, replace the detector. The VSR waterflow switch should provide years of trouble -free service. The retard and switch assembly are easily field replaceable. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock #1029030 (see Fig. 8). There is no maintenance required, only periodic testing and inspection. Retard/Switch Assembly Replacement (See Fig. 8) The Retard/Switch Assembly is field -replaceable without draining the system or removing the waterflow switch from the pipe 1. Make sure the fire alarm zone or circuit connected to the waterflow switch is bypassed or otherwise taken out of service. 2. Disconnect the power source for local bell (if applicable). 3. Identify and remove all wires from the waterflow switch. 4. Remove the (2) mounting screws holding retard/switch assembly to the base. Do not remove the (2) retard housing screws. 5. Remove the retard assembly by lifting it straight up over the tripstem. 6. Install the new retard assembly. Make sure the locating pins on the retard/switch assembly fit into the locating pin bosses on the base. 7. Re -install the (2) original mounting screws. 8. Reconnect all wires. Perform a flow test and place the system back in service. Fig. 8 DO NOT REMO'V (2) RETARD HOL SCREWS Removal of Waterflow Switch REMOVE (2) ORIGINAL MOUNTING SCREWS HOLDING RETARD/SWITCH ASSEMBLY TO BASE BREAKOUTTHIN SECTION OF COVER WHEN WIRING BOTH SWITCHES FROM ONE CONDUIT ENTRANCE. (2) ORIGINAL MOUNTING CREWS RETARD/SWITCH ASSEMBLY Li (2) LOCATING PINS/ n (2) LOCATR BOSSES IN DWG# 1146-10 • To prevent accidental water damage, all control valves should be shut tight and the system completely drained before waterflow detectors are removed or replaced. • Turn off electrical power to the detector, then disconnect wiring. • Loosen nuts and remove U-bolts. • Gently lift the saddle far enough to get your fingers under it. With your fingers, roll the vane so it will fit through the hole while continuing to lift the waterflow detector saddle. • Lift detector clear of pipe. PRINTED IN USA MFG. #5401146 - REV M PAGE 4 OF 4 11115 (E)POTTER The Symbol of Protection Features • Listed for indoor and outdoor use • Outdoor use requires BBK-1 or HC-BB weatherproof back box • Indoor use mounts directly to standard 4" box • Low current draw • High dB output • AC and DC models • DC models are motor driven, polarized, and have built in transient protection for supervised alarm circuits • Available in 6", 8" and 10" sizes Description These vibrating type bells are designed for use as fire or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4" (101mm) square electrical box for indoor use or on a model BBK-1 or HC-BB weatherproof backbox for outdoor applications. Weatherproof backbox model BBK- 1 or HC-BB, Stock No. 1500001. Notes 1. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30' to 150°F (-34° to 66°C) 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. 3. ULC only applies to MBA DC bells. Size inches (mm) Voltage Model Number Stock Number Current (Max.) Typical dB at 10 ft. (3m) (2) Minimum dB at 10 ft. (3m) (1) 6 (150) 12VDC MBA-6-12 1750070 .12A 85 76 8 (200) 12VDC MBA-8-12 1750080 .12A 90 77 10 (250) 12VDC MBA-10-12 1750060 .12A 92 I 78 6 (150) 1 24VDC MBA-6-24 1750100 .06A 87 77 8 (200) 24VDC MBA-8-24 1750110 .06A 91 79 10 (250) 24VDC MBA-10-24 1750090 .06A 94 80 6 (150) 24VAC PBA246 1806024* .17A 91 78 8 (200) 24VAC PBA248 1808024* .17A 94 77 10 (250) 24VAC PBA2410 1810024* .17A 94 78 6 (150) 120VAC PBA1206 1806120* .05A 92 83 8 (200) 120VAC PBA1208 1808120* .05A 99 84 10 (250) 120VAC PBA12010 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. * Does not have ULC listing. Potter Electric Signal Company, LLC St. Louis, MO BELLS PBA AC & MBA -DC ( 0 U U C F M ;� �: a.... APPROVED * ULC on MBA -DC Only Technical Specifications Dimensions 6" (150mm), 8" (200mm) and 10" (250mm) Cover: Steel Finish: Red Powder Coat Enclosure Base: non -corrosive composite material All parts have corrosion resistant finishes Model BBK-1 or HC-BB weatherproof backbox (optional) 24VAC Voltages Available 120VAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Indoor or outdoor use (See Note 1) Environmental -400 to 150OF (-400 to 66°C) Limitations (Outdoor use requires weatherproof backbox.) Termination AC Bells - 4 No. 18 AWG stranded wires DC Bells - Terminal strip Service Use NFPA 13, 72, local AHJ *Specifications subject to change without notice. W WARNING Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. • Shock hazard. Disconnect power source before servicing. Serious injury or death could result. Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. WEE6:W:A:RNING In outdoor or wet installations, bell must be mounted with rweatherproof backbox, BBK-1 or HC-BB. Standard electrical boxes will not patherproofenclosure. If the bell and/or assembly is exposed to moisture,r create an electrical hazard. Phone: 800-325-3936 www.pottersignal.com 5400776 - REV Z • 11/17 PAGE 1 OF 2 (E)POTTER BELLS The Symbol of Protection PBA AC & MBA -DC Installation The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90" AFF and not less than 6" below the ceiling. 1. Remove the gong. 2. Connect wiring (see Fig. 3). 3. Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). 4. Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). 5. Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). Weatherproof Backbox Dimensions WARNING Inches (mm)WF.i1tuue,..inst.a11 striker down will prevent bell from ringing. MODEL BBK-1 OR HC-BB Fig 2 Bell Dimension Inches (mm) Fig 1 5 3/4" O 046 —) 10" (250mm) 8„ ----� — (200 mm) 6" (150 mm) J J (41 mm) L 2 11/16" (68 mm) DWGq 776-1 Wiring Rear View Fig 3 D.C. BELLS (OBSERVE POLARITY) A.C. BELLS 338' (86 —) 4 1/4" (108 —) 3 3/8" 5" (86—) (127—) RED (IN) RED (OUT) WHITE (IN) WHITE (OUT) 0 0 FROM CONTROL PANEL CIB EXT BELL FROM CONTROL PANEL OR D-OF-LINE OR PRECEDING BELL SISTOR PRECEDING BELL BLACK (IN) T) BLACK (IN) CBLACK CAUTION• WHEN ELECTRICAL SUPERVISION 15 REQUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: CAUTION; WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN - NOTES: 1. OBSERVE POLARITY TO RING D.C. BELLS. 1. WHEN USING A.C. BELLS, TERMINATE EACH EXTRA WIRE SEPERATELY 2. RED WIRES POSITIVE (+). AFTER LAST BELL. 3. BLACK WIRES NEGATIVE (-). 2. END -OF -LINE RESISTOR IS NOT REQUIRED ON AC BELLS . 4. EOL RESISTOR IS SUPPLIED BY FIRE ALARM CONTROL PANEL. Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 5400776 - REV Z • 11/17 PAGE 2 OF 2 Sprinklers tqC00 Worldwide I www.tyco-fire.com Contacts RAPID RESPONSE Series LFII Residential 4.9 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and Dry Pipe Systems General Description The TYCO RAPID RESPONSE Series LFII Residential 4.9K Concealed Pendent Sprinklers (TY3596) are dec- orative, fusible solder sprinklers, avail- able in both ordinary 160°F (71°C) and intermediate 212°F (100°C) tempera- ture rated configurations. They are designed for use in residential occu- pancies such as homes, apartments, dormitories, and hotels. The cover plate assembly conceals the sprinkler operating components above the ceiling. The flat profile of the cover plate provides the optimum aes- thetically appealing sprinkler design. In addition, the concealed design of the Series LFII Residential Con- cealed Pendent Sprinklers provides 1/2 in. (12,7 mm) vertical adjustment. This adjustment provides a measure of flexibility when cutting fixed sprin- kler drops. The Series LFII Residential Concealed Pendent Sprinklers are intended for use in the following scenarios: • Wet and dry pipe residential sprin- kler systems for one and two fam- ily dwellings and mobile homes per NFPA 13D • Wet and dry pipe residential sprin- kler systems for residential occupan- cies up to and including four stories in height per NFPA 13R IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. • Wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 The Series LFII Residential Concealed Pendent Sprinklers have been designed with heat sensitivity and water distri- bution characteristics proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. The Series LFII Residential Con- cealed Pendent Sprinklers (TY3596) are shipped with a Disposable Protec- tive Cap. The Protective Cap is tem- porarily removed for installation, and then it can be replaced to help protect the sprinkler while the ceiling is being installed or finished. The tip of the Pro- tective Cap can also be used to mark the center of the ceiling hole into the plaster board, ceiling tiles, and so on, by gently pushing the ceiling product against the Protective Cap. When the ceiling installation is complete the Pro- tective Cap is removed and the Cover Plate Assembly is installed. Dry Pipe System Application The 160°F (71°C) temperature rated Series LFII Residential Concealed Pendent Sprinklers offer a laboratory approved option for designing dry pipe residential sprinkler systems, whereas, most residential sprinklers are labora- tory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Concealed Pendent Sprinklers need not be increased over the number of design sprinklers (hydraulic design area) as specified for wet pipe sprinkler systems, as is accustomed for density/ area sprinkler systems designed per NFPA 13. Consequently, the Series LFII Residen- tial Concealed Pendent Sprinklers offer the features of non -water filled pipe in addition to not having to increase the number of design sprinklers (hydraulic design area) for systems designed to NFPA 13, 13D, or 13R. NOTICE The Series LFII Residential Concealed Pendent Sprinklers (TY3596) described herein must be installed and main- tained in compliance with this docu- ment and with the applicable standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TY3596 Page 1 of 6 SEPTEMBER 2019 TFP442 TFP442 Page 2 of 6 Technical Data Approvals UL and C-UL Listed NYC Approved under MEA 44-03-E-2NSF Certified to all requirements of NSF/ANSI 61 Australian WaterMark Certified The TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprinklers are Listed only when installed with LFII Con- cealed Cover Plates having factory -applied finishes. Sprinklers and Cover Plates are separately ordered. See the Ordering Procedure section for more information. Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K=4.9 GPM/psi' (70,6 LPM/bar") Temperature Rating Ordinary 160°F (71°C) Sprinkler/ 139°F (59°C) Cover Plate NOTE: Maximum Ambient Ceiling Temperature for the ordinary temperature configuration is 100°F (38°C) Intermediate* 212°F (100°C) Sprinkler/ 165°F (74°C) Cover Plate *For wet pipe systems only NOTE: Maximum Ambient Ceiling Temperature for the intermediate temperature configuration is 150°F (65°C) Vertical Adjustment 1/2 in. (12,7 mm) Finishes See the Ordering Procedure section Physical Characteristics Body..............................Brass Cap..............................Bronze Saddle.............................Brass Sealing Assembly. Beryllium Nickel w/TEFLON Soldered Link Halves ................ Nickel Lever.............................Bronze Compression Screw .................. Brass Deflector .................. Copper or Brass Guide Pin Housing ..................Bronze Guide Pins ......... Stainless Steel or Bronze Support Cup ....................... Steel Cover Plate ................. Copper/Brass** Retainer ......................... Copper Cover Plate Ejection Spring .... Stainless Steel ** Brass Cover Plate is offered for Intermediate Tem- perature 165°F (74°C) only. Operation When exposed to heat from a fire, the Cover Plate, which is normally soldered to the Retainer at three points, falls away to expose the sprinkler assembly. At this point the Deflector supported by the Arms drops down to its operated position. The fusible link of the sprin- kler assembly is comprised of two link halves that are soldered together with a thin layer of solder. When the rated temperature is reached, the solder melts and the two link -halves separate BODY (1/2" NP CAP SADDLI SUPPOF CUP W11 ROLL FORI THREAC GUIDE PIN GUIDE P HOUSIN THREADINTO SUPPOR CUP UNT MOUNTIN SURFACE FLUSH WI' CEILING SOLDEF TAB SPRINKLER ASSEMBLY ASSEMBLY FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER (TY3596) allowing the sprinkler to activate and flow water. Design Criteria The TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprinklers (TY3596) are UL and C-UL Listed for installation in accordance with this section. Note: When conditions exist that are outside the scope of the provided cri- teria, refer to the Residential Sprinkler Design Guide TFP490 for the manu- facturer's recommendations that may be acceptable to the authority having jurisdiction. System Types Per the UL and C-UL Listing, the 160°F (71°C) and 212°F (100°C) LFII Residential Concealed Pendent Sprin- klers may be utilized in wet pipe systems. Only the 160°F (71°C) LFII Res- ;EALING )SEMBLY 'RINKLER IENCHING AREA 1PRESSION SCREW LEVER _DER LINK LEMENT FLECTOR PERATED OSITIOM RETAINER H THREAD )IMPLES JECTION SPRING COVER PLATE idential Concealed Pendent Sprinklers may be utilized in dry pipe systems, per the UL and C-UL Listing. Refer to Technical Data Sheet TFP485 about the use of residential sprinklers in residential dry pipe systems. Ceiling Types Smooth flat horizontal, beamed, or sloped in accordance with NFPA 13D, 13R, or 13 as applicable. Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the minimum required sprin- kler flow rates are given in Tables A and B as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R. TFP442 Page 3 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure2,3 Maximum Coverage Maximum Temp. Rating Area' p Sfting 160°F (71°C), 212°F (100°C) Minimum ft x ft (m) Deflector to Installation Spacing (m x m) Flow Pressure Ceiling Type ft GPM psi (m) (LPM) (bar) 12 x 12 12 13 7.0 (3,7 x 3,7) (3,7) (49,2) (0,48) Smooth Ceilings 14 x 14 14 13 7.0 7/8 to 1-1/8 in. (4,3 x 4,3) (4,3) (49,2) (0,48) Beamed Ceilings per NFPA 13D or Concealed 8 16 x 16 16 13 7.0 (4,9 x 4,9) (4,9) (49,2) (0,48) 13R, or 13. Installed in (2,4) 18 x 18 18 17 12.0 beam (5,5 x 5,5) (5,5) (64,3) (0,83) 7/8 to 1-1/8 in. below bottom 20 x 20 20 20 16.7 of beam (6,1 x 6,1) (6,1) (75,7) (1,15) Notes: 1. For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. 2. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. See Hydraulic Design under the Design Criteria section. 3. For NFPA 13 residential applications, the greater of 0.1 GPM/ft2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENT SPRINKLER (TY3596) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Minimum Flowand Residual Pressure 2,3 Maximum Coverage Maximum Ordinary Temp. Rating Area' Spacing 160°F (71°C) Minimum ft x ft (m) Deflector to Installation Spacing (m x m) Flow Pressure Ceiling Type ft GPM psi (m) (LPM) (bar) 12 x 12 12 13 7.0 (3,7 x 3,7) (3,7) (49,2) (0,48) Smooth Ceilings 14 x 14 14 14 8.2 7/8 to 1-1/8 in. (4,3 x 4,3) (4,3) (53,0) (0,57) Beamed Ceilings per NFPA 13D or Concealed 8 16 x 16 16 15 9.4 (4,9 x 4,9) (4,9) (56,8) (0,65) 13R, or 13. Installed in (2,4) 18 x 18 18 18 13.5 beam (5,5 x 5,5) (5,5) (68,1) (0,93) 7/8 to 1-1/8 in. below bottom 20 x 20 20 21 18.4 of beam (6,1 x 6,1) (6,1) (79,5) (1,27) Notes: 1. For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. 2. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated us- ing the nominal K-factor. See Hydraulic Design under the Design Criteria section. 3. For NFPA 13 residential applications, the greater of 0.1 GPM/ft2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM RAPID RESPONSE SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENT (TY3596) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA TFP442 Page 4 of 6 2-1/2" DIA. _ (63,5 mm) 1/2" (12,7 mm) 1/2 THREADED NPT, ADJUSTMENT COVER- SPRINKLER - RETAINER SUPPORT CUP ASSEMBLY ASSEMBLY 3-3/16" DIA. _ (81,0 mm) TEMPERATURE RATING PROFILE DEPTH AIR GAP ORDINARY 3/16" (4,8 mm) 1/8" (3,2 mm) INTERMEDIATE 5/32" (4,0 mm) 3/32" (2,4 mm) 1 FACE OF SPRINKLER 1-7/8"t1/4" FITTING (47,6 mm MOUNTING t6,4 mm) SURFACE � t PROFILE AIR DEPTH GAP (SEE (SEE TABLE) TABLE) SPRINKLER SUPPORT Cl ASSEMBLY 5/8" (15,9 mr 1-1/8" (28,6 m LE TIP PROTECTIVE CAP COVER PLATE OPERATED RETAINER SPRINKLER DEFLECTOR IN OPERATED POSITION FIGURE 2 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER (TY3596) INSTALLATION DIMENSIONS, PROTECTIVE CAP, AND ACTIVATED DEFLECTOR The number of "design sprinklers" specified in NFPA 13D and 13R for wet pipe systems is to be applied when designing dry pipe systems. Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: • The flow rates given in Tables A and B as a function of temperature rating and the maximum allowable cover- age area • A minimum discharge of 0.1 GPM/ft2 over the design area comprised of the four most hydrauli- cally demanding sprinklers for actual coverage areas protected by the four sprinklers The number of design sprinklers speci- fied in NFPA 13 for wet pipe systems is to be applied when designing dry pipe systems. Dry Pipe System Water Delivery When using the Series LFII Residen- tial Concealed Pendent Sprinklers in dry pipe sprinkler systems, the time for water delivery must not exceed 15 seconds for the most remote operat- ing sprinkler. Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational Sensitivity The sprinklers are to be installed rela- tive to the ceiling mounting surface as shown in Figure 2. Sprinkler Spacing The minimum spacing between sprin- klers is 8 ft (2,4 m). The maximum spacing between sprinklers cannot exceed the length of the coverage area (see Table A or B) being hydraulically calculated, for example, maximum 12 ft for a 12 ft x 12 ft coverage area, or 20 ft for a 20 ft x 20 ft coverage area. The Series LFII must not be used in applications where the air pres- sure above the ceiling is greater than that below. Down drafts through the Support Cup could delay sprinkler operation in a fire situation. Installation The TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprinklers (TY3596) must be installed in accordance with this section. General Instructions Damage to the fusible Link Assembly during installation can be avoided by handling the sprinkler by the support cup only. Therefore, do not apply pres- sure to the fusible Link Assembly. A 1/2 in. NPT sprinkler joint should be obtained with a minimum to maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N•m). Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Cover Plate Assembly by under -or over - tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 18 SPRINKLER WRENCH Step 1. The sprinkler must only be installed in the pendent position and with the centerline of the sprinkler per- pendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant applied to the pipe threads, and using the W-Type 18 Wrench shown in Figure 3, install and tighten the Sprinkler/ Support Cup Assembly into the fitting. The W-Type 18 Wrench will accept a 1/2 in. ratchet drive. Step 4. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. The Protec- tive Cap helps prevent damage to the Deflector and Guide Pins during ceiling installation and/or during application of the finish coating of the ceiling. It may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Cap. TFP442 Page 5 of 6 Note: As long as the protective Cap remains in place, the system is consid- ered to be "Out Of Service." Step 5. After the ceiling has been com- pleted with the 2-1/2 in. (63 mm) diam- eter clearance hole and in preparation for installing the Cover Plate Assembly, remove and discard the Protective Cap, and verify that the Deflector moves up and down freely. If the sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire sprinkler assembly. Do not attempt to modify or repair a damaged sprinkler. Step 6. Push on the Cover Plate Assembly until its flange comes in contact with the ceiling. Do not continue to push on the Cover Plate Assembly such that it lifts a ceiling panel out of its normal position. If the Cover Plate Assembly cannot be engaged with the Mounting Cup or the Cover Plate Assembly cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. Care and Maintenance The TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprinklers (TY3596) must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of a Cover Plate may delay the sprinkler operation in a fire situation. When properly installed, there is an air gap between the lip of the Cover Plate and the ceiling. The Ordinary Tem- perature Cover Plate assembly has a nominal 1/8 in. (3,2 mm) air gap. The Intermediate Temperature Cover Plate has a nominal 3/32 (2,4 mm) air gap, as shown in Figure 2. This air gap is necessary for proper operation of the sprinkler by allowing heat flow from a fire to pass below and above the Cover Plate to help assure appropriate release of the Cover Plate in a fire situation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted units. Non -factory applied paint may adversely delay or prevent sprinkler operation in the event of a fire. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied or over heated sprinklers must be replaced. Care must be exercised to avoid damage before, during, and after instal- lation. Sprinklers damaged by drop- ping, striking, wrench twist/slippage, or the like, must be replaced. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSOCIATION, for example, NFPA 25, in addition to the standards of any other authorities having jurisdiction. Contact the installing contractor or product manufacturer with any questions. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non - operation in the event of a fire or inad- vertent operation may result. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and part number (P/N). Sprinkler Assemblies Specify: Series LFII (TY3596) 4.91K Res- idential Concealed Pendent Sprinkler, P/N (specify): 160'F(71°C) ...................51-112-1-160 212°F(100°C)..................51-112-1-212 Note: Sprinkler and Cover Plates are separately sold. See below for Cover Plate ordering information. Cover Plate Assemblies Specify: LFII Concealed Sprinkler Cover Plate Assembly, temperature rating (specify), (specify) finish, P/N (specify): 139'F(59°C) Ivory (RAU 015) ............... 56-204-0-135 Bright Chrome ................ 56-204-1-135 Beige (RAL1001) .............. 56-204-2-135 Pure White (RAL9010)* .........56-204-3-135 Signal White (RAL9003)** .......56-204-4-135 Grey White (RAL9002).......... 56-204-5-135 Brown(RAL8028)..............56-204-6-135 Black (RAL9005) .............. 56-204-7-135 Brushed Brass ................56-204-8-135 Brushed Chrome ..............56-204-9-135 Custom Paint .................56-204-X-135 165°F (74°C) Ivory (RAU 015) ............... 56-204-0-165 Bright Chrome ................ 56-204-1 165 Beige (RAL1001) ..............56-204-2-165 Pure White (RAL9010)* .........56-204-3-165 Signal White (RAL9003)'* .......56-204-4-165 Grey White (RAL9002).......... 56-204-5-165 Brown(RAL8028)..............56-204-6-165 Black (RAL9005) .............. 56-204-7-165 Brushed Brass ................56-204-8-165 Brushed Chrome ..............56-204-9-165 Custom Paint .................56-204-X-165 'Eastern Hemisphere sales only "Previously known as Bright White Note: All Custom Cover Plates are painted using SHERWIN-WILLIAMS Interior Latex Paint. Contact Johnson Controls Customer Service with any questions related to custom orders. Sprinkler Wrench Specify: W-Type 18 Sprinkler Wrench, P/N 56-000-1-265 TFP442 Page 6 of 6 1400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone A-215-362-0700 02019 Johnson Controls. All rights reserved. All specifications and other Information shown were current as of document revision date and are subject to change without notice. Johnson 400 NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; Controls TEFLON is a registered trademark of DuPont; SHERWIN-WILLIAMS is a registered trademark of SWIMC LLC tqC00 Worldwide I www.tyco-fire.com Contacts RAPID RESPONSE Series LFII Residential Sprinklers 4.4 K-factor Horizontal Sidewall Wet Pipe Systems General Description The TYCO RAPID RESPONSE Series LFII Residential Horizontal Sidewall Sprinklers (TY2334) are decorative, fast response, frangible bulb sprinklers designed for use in residential occu- pancies such as homes, apartments, dormitories, and hotels. When aesthet- ics and optimized flow characteristics are the major consideration, the Series LFII Residential Sprinklers (TY2334) should be the first choice. The Series LFII Residential Sprinklers are intended for use in the following scenarios: • wet pipe residential sprinkler sys- tems for one -and two-family dwell- ings and mobile homes per NFPA 13D • wet pipe residential sprinkler sys- tems for residential occupancies up to and including four stories in height per NFPA 13R • wet pipe sprinkler systems for the residential portions of any occu- pancy per NFPA 13 The recessed version of the Series LFII Residential Sprinklers is intended for use in areas with finished walls. It employs a two-piece Style 20 Recessed Escutcheon. The Recessed Escutcheon provides 1/4 in. (6,4 mm) of recessed adjustment or up to 1/2 in. (12,7 mm) of total adjustment from the flush mounting surface position. The IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. adjustment provided by the Recessed Escutcheon reduces the accuracy to which the pipe nipples to the sprinklers must be cut. The Series LFII Residential Sprinklers has been designed with heat sensitivity and water distribution characteristics proven to help in the control of residen- tial fires and to improve the chance for occupants to escape or be evacuated. Corrosion -resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo- spheres. Although corrosion -resistant coated sprinklers have passed the standard corrosion tests of the appli- cable Approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. NOTICE The Series LFII Residential Horizontal Sidewall Sprinklers (TY2334) described herein must be installed and main- tained in compliance with this docu- ment and with the applicable standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. I:A 1 NSF® Sprinkler Identification Number (SIN) TY2334 Page 1 of 6 SEPTEMBER 2019 TFP412 TFP412 Page 2 of 6 Components: 1 Frame 2 Button 3 Sealing TOP -OF - Assembly DEFLECTOR 4 - Bulb 5 -Compression 1 Screw 6 - Deflector* * Temperature rating is indicated on top of Deflector. 7/16" (11,1 mm) END -OF - DEFLECTOR BOSS WRENCH FLATS O 112" NPT 7/16" (11,1 mm) NOMINAL 6* 5 4 2 MAKE -IN CENTERLINE OF WATERWAY 3 (38,1 mm) ESCUTCHEON 2-1/8" _ PLATE SEATING (54,0 mm) -I SURFACE WRENCH FLATS STYLE 20 RECESSED ESCUTCHEON RECESSED FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS (TY2334) 7/16±1 /8" (11,1±3,2 mm) MOUNTING FACE OF SURFACE SPRINKLER FITTING TOP -OF- CLOSURE DEFLECTOR } TY2334 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) 7/16" 1 (11,1 mm) MOUNTING PLATE END -OF - DEFLECTOR 1/8" BOSS (3,2 mm) 1-1/4" (31,8 mm) 1/2" (12,7 mm) 1" (25,4 mm) 1/4" (6,4 mm) FIGURE 2 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE RAPID RESPONSE SERIES LFII RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER (TY2334) Technical Data Approvals UL and C-UL Listed Certified to all requirements of NSF/ANSI 61 Australian WaterMark Certified Note: Sprinklers with a polyester finish are UL Listed as corrosion -resistant sprinklers. See the Design Criteria section for details on these approvals. Maximum Working Pressure Maximum 175 psi (12,1 bar) Discharge Coefficient K= 4.4 GPM/psis= (63,4 LPM/bar%) Temperature Rating 155°F (68°C) or 175°F (79°C) 2-7/8" DIA. (73,0 mm) / WRENCH RECESS (END "A" USED FOR TY2334) FIGURE 3 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH Finishes Natural Brass, Signal White Polyester Coated, or Chrome Plated Physical Characteristics Frame .............................Brass Button............................Bronze Sealing Assembly. Beryllium Nickel w/ TEFLON Bulb..........................3 mm Glass Compression Screw ................. Bronze Deflector ......................... Copper TFP412 Page 3 of 6 Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb allowing the sprinkler to acti- vate and flow water. Design Criteria The TYCO RAPID RESPONSE Series LFII (TY2334) Residential Horizontal Sidewall Sprinklers are UL and C-UL Listed for installation in accordance with this section. Residential Sprinkler Design Guide When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufactur- er's recommendations that may be acceptable to the local authority having jurisdiction. System Type Only wet pipe systems may be utilized. Ceiling Type Smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R, or 13 as applicable. Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the minimum required sprin- kler flow rate are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of design sprinklers as specified in NFPA 13D or NFPA 13R. Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: • The flow rates given in Table A as a function of temperature rating and the maximum allowable coverage area. • A minimum discharge of 0.1 gpm/ft2 over the "design area" comprised of the four most hydraulically demand- ing sprinklers for the actual cover- age areas being protected by the four sprinklers. Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational Sensitivity The sprinklers are to be installed with an end of defector -boss to wall dis- tance of 1-1/8 in. to 6 in. In addition the top -of -deflector -to - ceiling distance is to be within the range (see Table A) being hydraulically calculated. Sprinkler Spacing The minimum spacing between sprin- klers is 8 ft (2,4 m). The maximum spacing between sprinklers cannot exceed the width of the coverage area (see Table A) being hydraulically calcu- lated, for example, maximum 12 ft for a 12 ft x 12 ft coverage area, or 16 ft for a 16 ft x 20 ft coverage area. Installation The TYCO RAPID RESPONSE Series LFII (TY2334) Residential Horizontal Sidewall Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb -type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm). A leak -tight 1/2 in. NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N•m). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the sprinkler by under- or over -tightening the sprin- kler. Re -adjust the position of the sprin- kler fitting to suit. Series LFII Residential Horizontal Sidewall Sprinklers The Series LFII Horizontal Sidewall Sprinklers must be installed in accor- dance with the following instructions. Step 1. Horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of water- way perpendicular to the back wall and parallel to the ceiling. The word "TOP" on the Deflector is to face towards the ceiling with the front edge of the Deflector parallel to the ceiling. Step 2. With pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (see Fig- ure 3). With reference to Figure 1, the W-Type 6 Sprinkler Wrench is to be applied to the wrench flats. Series LFII Residential Recessed Horizontal Sidewall Sprinklers The Series LFII Recessed Horizontal Sidewall Sprinklers must be installed in accordance with the following instructions. Step A. Recessed horizontal sidewall sprinklers are to be installed in the hor- izontal position with their centerline of waterway perpendicular to the back wall and parallel to the ceiling. The word "TOP" on the Deflector is to face towards the ceiling. Step B. After installing the Style 20 Mounting Plate over the sprinkler threads and with pipe thread seal- ant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (see Fig- ure 4). With reference to Figure 1, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step D. After the wall has been installed or the finish coat has been applied, slide on the Style 20 Closure over the Series LFII Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the wall. TFP412 Page 4of6 WET PIPE SYSTEM Max. Minimum Flow and Residual Pressure(b, C) Max. Coverage Ordinary Temp. Rating Intermediate Temp. Rating Minimum Area (a) Spacing Width x Length (d) ft (m) 155°F (68°C) 175°F (79°C) Deflector to Installation Spacing Flow Pressure Flow Pressure ft x ft Ceiling Type ft (m x m) GPM PSI GPM PSI (m) (L/min) (bar) (L/min) (bar) 12 x 12 12 13 8.7 13 8.7 (3,7 x 3,7) (3,7) (49,2) (0,60) (49,2) (0,60) 14 x 14 14 14 10.1 14 10.1 (4,3 x 4,3) (4,3) (53,0) (0,70) (53,0) (0,70) 16 x 16 16 16 13.2 16 13.2 (4,9 x 4,9) (4,9) (60,6) (0,91) (60,6) (0,91) 4in. to 16x18 16 19 18.6 19 18.6 (4,9 x 5,5) (4,9) (71,9) (1,28) (71,9) (1,28) 6 in. 16 x 20 16 23 27.3 23 27.3 (4,9 x 6,1) (4,9) (87,1) (1,88) (87,1) (1,88) 18 x 18 18 23 27.3 23 27.3 (5,5 x 5,5) (5,5) (87,1) (1,88) (87,1) (1,88) Recessed 2 18 x 20 18 26 34.9 26 34.9 (5,5 x 6,1) (5,5) (98,4) (2,41) (98,4) (2,41) Escutcheon or non -recessed 8 (2,4) 12 x 12 12 13 8.7 13 8.7 (3,7 x 3,7) (3,7) (49,2) (0,60) (49,2) (0,60) per NFPA 13D, 13R, or 13 14 x 14 14 14 10.1 14 10.1 (4,3 x 4,3) (4,3) (53,0) (0,70) (53,0) (0,70) 16 x 16 16 17 14.9 17 14.9 (4,9 x 4,9) (4,9) (64,3) (1,03) (64,3) (1,03) 6 in. to 16 x 18 16 20 20.7 20 20.7 (4,9 x 5,5) (4,9) (75,7) (1,43) (75,7) (1,43) 12 in. 16 x 20 16 23 27.3 23 27.3 (4,9 x 6,1) (4,9) (87,1) (1,88) (87,1) (1,88) 18 x 18 18 23 27.3 23 27.3 (5,5 x 5,5) (5,5) (87,1) (1,88) (87,1) (1,88) 18 x 20 18 26 34.9 26 34.9 (5,5 x 6,1) (5,5) (98,4) (2,41) (98,4) (2,41) Notes: a. For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. b. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. See Hydraulic Design under the Design Criteria section. c. For NFPA 13 residential applications, the greater of 0.1 gpm/ftz over the design area or the flow in accordance with the criteria in this table must be used. d. The Width x Length dimension refers to the Width (backwall where the sprinkler is located) times the Length (horizontal throw of sprinkler). TABLE A WET PIPE SYSTEMS SERIES LFII (TY2334) RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS NFPA 13D, 13R AND 13 WET PIPE HYDRAULIC DESIGN CRITERIA TFP412 Page 5 of 6 Care and Limited Maintenance Warranty The TYCO RAPID RESPONSE Series For warranty terms and conditions, LFII (TY2334) Residential Horizontal visit www.tyco-fire.com. Sidewall Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of an Escutcheon Plate may delay the sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non - operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers - before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. Seethe Installation section for additional information. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSOCIATION, for example, NFPA 25, in addition to the standards of any other authorities having jurisdiction. Contact the installing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N): Sprinkler Assembly Specify: Series LFII (TY2334), K=4.4, Residential Horizontal Sidewall Sprin- kler, (specify) temperature rating, (specify) finish, P/N (specify): 155-F(68°C) Natural Brass ................. 51-215-1-155 Signal White (RAL9003) Polyester' .................... 51-215-4-155 Chrome Plated ................ 51-215-9-155 175°F(79°C) Natural Brass ................. 51-215-1-175 Signal White (RAL9003) Polyester' .................... 51-215-4-175 Chrome Plated ................ 51-215-9-175 1. UL Listed as corrosion -resistant. Recessed Escutcheon Specify: Style 20 Recessed Escutcheon with (specify*) finish, P/N (specify*). ' Refer to Technical Data Sheet TFP770. Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 TFP412 Page 6 of 6 1400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone A-215-362-0700 02019 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. Johnson 400 NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; Controls TEFLON is a registered trademark of DuPont Miscellaneous ARGCO dI:1=11--i:3:1I►,I:/g4:�&-i:JA:1=1:I4A11-1•): * Heavy duty 20 gauge steel construction Red powder coated finish Knockouts and shelf to accommodate any 1/2" or 3/4" sprinkler head All -welded construction and full length hinge Slotted for easy mounting with screws, rivets or strapping 3 Head Box 6510152 6 Head Box 6510151 12 Head Box 6510150 6 large Head Box (6510151A) The information contained herein is produced in good faith and is believed to be reliable but is for guidance only. ARGCO and its agents cannot assume liability or responsibility for results obtained in the use of its product by persons whose methods are outside or beyond our control. It is the user's responsibility to determine the suitability of any of the products, methods of use, or preparation prior to use, mentioned in our literature. It is the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of any of our products. FOR MORE INFORMATION CALL ARGCO AT 1-800-854-1015 OR LOG ONTO WWW.ARGCO.COM SPEARS° MANUFACTURING COMPANY �ti y FS-5 v:_. RED SPr aMeG ,C,S TECHNICAL SPECIFICATIONS Low VOC CPVC Solvent Cement PRODUCT: Spears® FlameGuard® FS-5 RED One -Step (no primer required) CPVC cement specifically formulated and approved for use with Spears® FlameGuard® and other approved CPVC Fire Sprinkler Products with interference fit through 3". INTENDED USE: Spears® FS-5 is approved for use with Spears® FlameGuard® and other approved CPVC Fire Sprinkler Products. See publication FG-3, FlameGuard® Installation Instructions for additional application details. GENERAL PRODUCT SPECIFICATIONS: COLOR: Red RESIN: CPVC SPECIFIC GRAVITY. 0.985 ± 0.04 BROOKFIELD VISCOSITY Heavy Body - Minimum 1600 cP@ 73 f 2°F (23°C +1° C) RELATIVE SET: Fast MAX VOC EMISSIONS: 490 G/L per SCAQMD Rule 1168/316A SHELF LIFE: 2 years from date stamped on the bottom of container. Note: Product usability is limited by the evaporation of the solvents when the container is opened and can cause the cement to thicken and reduce its usefulness. Always seal the can tightly between uses to prevent the solvent from becoming thickened, stringy or jelled. Do not add thinners to change viscosity of thickened cement. Significant changes in cement properties can result. CONFORMANCE STANDARDS AND APPROVALS: • NSF®/ANSI Standard 14 Listed and Certified for compliance to ASTM F493 • NSF®/ANSI Standards 14/61 Listed and Certified for Potable Water, Drain Waste and Vent, and Sewer service use (NSF®-PW, DWV, SW) NSF® Listed and Certified to requirements of the Uniform Plumbing Code (NSF® U.P. Code); NSF® Certified Lead -Free. • FM® and UL® approved for use with Spears® FlameGuard® and other approved CPVC Fire Sprinkler Products. • Meets SCAQMD Rule 1168/316A for Compliance with LEED® (Leadership in Energy and Environmental Design). Low VOC product credit can be claimed for LEED Green Building Rating System - Indoor Environmental Quality. PACKAGING, SHIPPING & TRANSPORTATION INFORMATION: Can Size Standard Case Ouantity Pint 12 Quart 12 The following is general information for ground shipping, see SDS FS5-6 for additional detail. Proper Shipping Name: Adhesive Exceptions for Quantities < 1 liter Hazard Class: 3 Classification: Limited Quantity Identification Number: UN 1133 49CFR172.315 Marking: Packing Group: II <:> Label Required: Class 3 Flammable Liquid Note: Purchasers who may repackage this product must also conform to all local, state and federal labeling, safety and other regulations. SAFETY & USE PRECAUTIONS: WARNING: CAN CAUSE SERIOUS EYE IRRITATION. HARMFUL IF INHALED. MAY CAUSE DROWSINESS OR DIZZINESS. MAY CAUSE RESPIRATORY IRRITATION. REPEATED EXPOSURE MAY CAUSE SKIN DRYNESS OR CRACKING. KEEP OUT OF REACH OF CHILDREN. Do not take internally. Keep away from heat, spark, open flame, other sources of ignition. Vapors may ignite explosively. Use only in well ventilated area; if not well ventilated, use forced ventilation or NIOSH approved respirator. Avoid breathing vapors. Do not smoke, eat or drink while using. Avoid contact with skin and eyes. Use skin and eye protection. Eye contact may cause injury. Keep container closed when not in use. Contains Tetrahydrofuran (CAS#109-99-9); Methyl Ethyl Ketone (CAS# 78-93-3); Cyclohexanone (CAS# 108-94-1); Acetone (CAS# 67-64-1); CPVC Resin (CAS# 68648-82-8). FIRST AID Contact with eyes: Flush eyes immediately with plenty of water for 15 minutes and seek medical advice immediately. Skin contact: Remove contaminated clothing and shoes. Wash skin thoroughly with soap and water. If irritation develops, seek medical advice. Inhalation: Remove to fresh air. If breathing is stopped, give artificial respiration. If breathing is difficult, give oxygen. Seek medical advice. Ingestion: Rinse mouth with water. Give 1 or 2 glasses of water or milk to dilute. Do not induce vomiting. Seek medical advice immediately. INSTALLATION & INSTALLER TRAINING FS-5 is specialty cement; see Spears® publication FG-3, F1ameGuard® Installation Instructions, for specific details and limitations. Installation instructions are printed on the can label and instructional information is available on Spears® website at www.spearsmfg.com. Certified Installers Training for FlameGuard® CPVC Fire Sprinkler Systems is also available. Contact Spears® for additional instructional information or formal training. AVOID USE AROUND DRY GRANULATED CALCIUM HYPOCHLORITE While CPVC Fire Sprinkler Systems typically are not disinfected, a fire or explosion may result if dry granular calcium hypochlorite is used to disinfect plastic piping systems that are exposed to organic vapors found in solvent cements, cleaners or primers when a water solution is not used. Calcium hypochlorite is a strong oxidizer and common in Pool & Spa chemicals such as "pool -shock". If required, it is recommended to purify lines by pumping nonvolatile chlorinated water into the piping system. Do not store or use dry granular calcium hypochlorite near solvent cements, cleaners and primers. Refer to Safety Data Sheet (SDS), Spears" publication FS5-6, for more information. LIMITED LIFETIME WARRANTY. - Spears" Manufacturing Company warrants all new Solvent Cement and Primer products shall be free from defects in material and workmanship for the specified product shelf life based on the assigned manufactured date on the original product container. If any such product becomes defective under normal use and storage conditions during this warranty period, Spears® will replace the nonconforming solvent cement or primer product without charge. Spears® liability will be limited, without exception, to product replacement. Spears® further warrants properly made solvent cement joints using this product for the life of the system. See Spears® standard Limited Lifetime Warranty for additional detailed information and exclusions. Progressive Products From Spears® Innovation & Technology SPEARS® MANUFACTURING COMPANY • CORPORATE OFFICE 'N T4F SPERRS 15853 Olden St., Sylmar, CA 91342 • PO Box 9203, Sylmar, CA 91392 (818) 364-1611 • www.spearsmfg.com © Copyright 2013 Spears® Manufacturing Company. All Rights Reserved. Printed in the United States of America 10113. FS-5TS-1013