FIR2021-0014+Fire_Sprinkler_Plan+2.12.2021_9.32.31_AM+2045380
(2) #905 SCREWS UNHEATEDAREA SCOPE OF WORK REDHAWK FIRE PROTECTION, LLC FIG. 187 (2) #905 FIG. 188 (2) #905 HANGER SCREWS W/ HANGER —SCREWS W/ BACKING NUTS BACKING NUTS CPVC PIPE (1" - 2" ONLY) FIG. 187 HANGER CPVC PIPE (1" - 2" ONLY) FIG. 188 HANGER TJI JOISTS TJI JOISTS AFCON FIG 187 TO WOOD JOIST CPVC STEEL HANGER W H 10 0 n 1 3 DRAIN TO EXTERIOR RHFP START POINT I —III —III —I 11=><—III—I I I I Li I I=1 11= RISER DETAIL A0 1' 2' 4' 8' SCALE: 1 /4"=1'-0" AFCON FIG 188 TO WOOD JOIST CPVC / STEEL HANGER CPVC PIPE (1" ONLY) FIG. 29 HANGER TJI JOISTS TOLCO FIG 29 TO WOOD JOIST CPVC STEEL HANGER RHFP STANDARD RESIDENTIAL RISER KIT ITEM #I QTY I SIZE DESCRIPTION MANUFACTURER 1 1 '/4 PRESSURE GAUGE GENERIC 2 2 1 CPVC MALE ADAPTER SPEARS 3 1 1 BALL VALVE FOR DRAIN GENERIC 4 1 1'/ x 1 VSR-SG WATERFLOW SWITCH POTTER 5 1 11/ CPVC UNION SPEARS ADDITIONAL COMPONENTS ITEM # QTY SIZE DESCRIPTION MANUFACTURER 6 1 11/ CPVC MALE ADAPTER SPEARS 7 1 1'/2 2000B DOUBLE CHECK BACKFLOW AM ES 8 1 1'/2 0-3 BRASS NIPPLE GENERIC 9 1 1'/2 THREADED FEMALE ADAPTER GENERIC 10 1 N/A* SPARE STOCK BOX GENERIC 11 1 6" / 120V ELECTRIC BELL (NOT SHOWN) POTTER 12 1 6 x 2 CONTROL VALVE SIGN (NOT SHOWN) GENERIC 13 1 6 x 2 MAIN DRAIN SIGN (NOT SHOWN) GENERIC *SPARE SPRINKLERS LEFT IN SPRINKLER BOX FITTER NOTES 01 - ALL CEILING HEIGHTS 8-0 AFF. 02- IF UNABLE TO INSTALL ASPRINKLER HEADAT THE PRE -DETERMINED LOCATION PER PLAN, ALIGN WITH OTHER FIRE SPRINKLERS, LIGHTS, AND/OR DOORS WHERE POSSIBLE. 03 - MAIN DRAIN TO RUN TO EXTERIOR OF RESIDENCE. FINAL LOCATION TO BE COORDINATED WITH GC/OWNER ON SITE. GAS FIREPLACE REMOTE AREA FIRE SPRINKLER PLAN -FIRST LEVEL SPRINKLER LEGEND NIR GAP REQUIRED FIRE SPRINKLER AROUNDALL WET PIPING (BY SPRINKLER PIPING RHFP) INSULATION TENTING (BY \ OTHERS) HEATEDAREA (ALL INSULATION BY OTHERS) INSULATION TENTING OVER SPRINKLER PIPE CROSS SECTION 0 2' 4' 8' 16' __ SCALE: 1 /8"=1 '-0" PIPE TENTING ALL ATTIC PIPING TO BE TENTED WITH BATT TYPE INSULATION TO SYMBOL MFR SIN MODEL Iii TYPE THREAD RESP FINISH TEMP NOTE QTY ' Tyco TY2334 LFII 4.4 Sidewall % Quick White 155OF None 2 Tyco TY3596 LFII 4.9 Pendent % Quick White 160OF Concealed 16 Tyco TY3596 LFII 4.9 Pendent % Quick White 212OF Concealed 1 Total =19 /fv2" X 12 NO SPRINKLER PROTECTION % REQURED IN GARAGES PER NFPA 13D (8.3.4) NO SPRINKLER PROTECTION REQUIRED IN BATHROOMS (<_ 55 FT 2) PER NFPA 13D (8.3.2) (TYP) ROOF OUTLINE NO SPRINKLER PROTECTION REQUIRED IN CLOSETS (5 24 FT2) PER NFPA 13D (8.3.3) (TYP) Hydraulic Information Remote Area 1 OCCUPANCY CLASSIFICATION Residential DENSITY (gpmlft2) 0.10 for 427.04ft2 TOTAL HEADS FLOWING 2 K-FACTOR 4.9 TOTAL WATER REQUIRED 34.84 TOTAL PRESSURE REQUIRED 50.748 BASE of RISER (gpm) 34.84 BASE of RISER (psi) 50.748 SAFETY MARGIN (psi) +17.236 (25.4%) IL � V N �OCZ` ♦ cArn 1'/2 CARRIED UP TO 2ND LEVEL D I6Ef7-2 FIRE SPRINKLER PLAN -SECOND LEVEL VI PROPERTY LINE RHFP START POINT I� I 2 I PROPOSED z I RESIDENCE W 21444 FT Q I = I N I I I DRIVEWAY _F ZI Q �I RED HAWK FIRE PROTECTION, LLC (RHFP) WILL PROVIDE ONE WET PIPE AUTOMATIC FIRE SPRINKLER SYSTEM TO PROTECTTHE ENTIRE NEW RESIDENCE. RHFPTO STARTAT 1'/2' WATER SUPPLY CONNECTION PROVIDED 6"ABOVE FINISH FLOOR IN THE GARAGE. ALLAREAS PROTECTED BYA WET SYSTEM MUST BE MAINTAINED BY OTHERS ATA MINIMUM 40°F TO PREVENT FREEZING. EXCLUSIONS PAINTING OR LABELING OF PIPE/EQUIPMENT, FURRING, CUTTING OR PATCHING ELECTRICAL WIRING OF ANY KIND, INCLUDING BUT NOT LIMITED TO WATERFLOW SWITCHES, TAMPER SWITCHES OR ELECTRIC BELLS WIRING AND SERVICING OF CENTRAL STATION MONITORING EQUIPMENT ALL UNDERGROUND WORK INCLUDING BUT NOT LIMITED TO: BACKFILL, SELECT FILL, BREAKING PATCHING, SAW CUTTING, LAWN REPAIR, LANDSCAPING, TREE REMOVAL, STERILIZATION, DEVELOPMENT FEES AND CITY CONNECTION GENERAL NOTES 01 - FIRE SPRINKLER SYSTEM TO BE DESIGNED, INSTALLED AND TESTED IN ACCORDANCE WITH NFPA 13D (2016) AND CITY OF EDMONDS (AHJ). 02 - RHFP SHALL NOT BE RESPONSIBLE FOR THE ABILITY OF THE STRUCTURE TO ADEQUATELY SUPPORTTHE FIRE SPRINKLER SYSTEM OR ANY APPURTENANCES THEREOF. 03 - IN LOCALITIES SUBJECTTO FREEZING CONDITIONS, IT IS THE OWNERS RESPONSIBILITY TO HEATTHE WET PIPE SPRINKLER SYSTEM AREAS AND IN ENCLOSURES WHERE DRY PIPE, DELUGE, AND OTHER TYPES OF VALVES CONTROLLING THE WATER SUPPLY EXIST. 04 - WHERE PIPE IS TO BE INSTALLED IN ATTIC OR JOIST SPACE EXPOSED TOA UNHEATED SPACE, PIPE IS TO BE "TENTED" TO THE HEATED SPACE WITH BATT INSULATION IN SUCH A WAYAS TO ALLOW HEATTO REACH SPRINKLER PIPING AND PROTECT FROM FREEZING. NO INSULATION IS TO BE BETWEEN THE HEATED SPACE AND SPRINKLER PIPE (BY OTHERS). 05 - ALL MATERIALS SHALL BE NEW AND ULAND/OR FM APPROVED. 06 - TYPICAL CPVC HANGER TO BE CPVC TYPE UNLESS NOTED OTHERWISE. ALL HANGERS TO BE SPACED AND INSTALLED PER NFPA 13D AND CPVC INSTALLATION GUIDE. 07 - ALL CPVC PIPE TO BE 1" UNLESS NOTED OTHERWISE. 08 - ALL PIPING SHOWN WITHOUT CUT LENGTHS TO BE CPVC WITH CPVC FITTINGS. WATER FLOW INFORMATION WATER FLOW INFORMATION TESTED BY CITY OF EDMONCS PUBLIC WORKS & UTILITIES AND PROVIDED BY PM ON 1/19/2021: STATIC PRESSURE RESIDUAL PRESSURE RESIDUAL FLOW 68 PSI 60 PSI 1000 GPM DESIGN CRITERIA PER NFPA 13D (2016) AND CITY OF EDMONDS RESIDENTIAL - MULTIPLE SPRINKLERS IN COMPARTMENT WET SYSTEM RESIDENTIAL 13D DESIGN DENSITY: 18x18 SPACING (17 GPM @ 12 PSI) / C2) MOST DEMANDING SPRINKLERS SYMBOLLEGEND X NEW CPVC SPRINKLER PIPE WITH LABEL ♦ PIPE HANGER --��� REMOTEAREABOUNDRY OHYDRAULIC NODE PLAN VIEW DETAIL A SECTION DETAILARROW POINTS X.XX VIEW DIRECTION 0" TS ELEVATION TAG j ELECTRIC FIRE ALARM BELL VICINITY MAP PROJECT SITE i 96,I�m 9W �Zuri, Edmonds College 0 f City of Lynnwood Municipal Golf ,;ourse __6" POTTER BELL PROVIDED BY RHFP V I United States (LOCATION AND INSTALL BY OTHERS) Postal Service roams sw SEATTLE.HEIGHT- �± 162 LF 11/2" CPVC FROM CITY MAIN I a TO RESIDENCE (BY OTHERS) Barge, King© ilim S, SW 11Rm5 Q Magic Toyota PROPERTY LINE _ Southwest Recyclingp �1" WATER METER StationEvanafer Sw (BY OTHERS) I Edmonds Campus© D WAY FIRE HYDRANT H E PAR K BORHOOD 4" CITY MAIN_ _ _ _ _ _ � Lynnwood Honda f F SITE PLAN FOR REFERENCE ONLY - NOT TO SCALE Lew V�Aal(( 801 VALLEY AVE NW, SUITE D PUYALLUP, WA 98371 PHONE: (253) 840-9900 FAX (800) 591-4382 WA CL# REDHAHF90I OP NICET Stamp 31 R Approvals Required CITY OF EDMONDS OWNER/ARCHITECT Contract With: RIDGELINE CONSTRUCTION 1203 12TH ST NE AUBURN, WA 98002 PM: TRAVIS NAKAMURA Phone: 206-349-5197 Email: travis@ridgelinenw.com Contract Name: CROUCH-MAUPIN RESIDENCE 1141 VIEWLAND WAY EDMONDS, WA 98020 Drawing Title FIRE SPRINKLER PLAN Date: Job Number: Designer: Building Permit: February 11, 2021 80260 BEN D. McQUAGE Drawing No. FP1 OF I 0 2' 4' 8' 16' W SCALE: 1 /8"=1'-0" W0 2_ 4' 8' 16' SCALE: 1 /8"=1 '-0"