APPROVED BLD PLN BLD2021-0693+Mechanical_SITE Plan+5.19.2021_1.43.25_PM+2206144MECHANICAL ABBREVIATIONS
A
AMPS
AC
AIR CONDITIONING
ACH
AIR CHANGES PER HOUR
ACT
ACOUSTICAL CEILING TILE
AD
ACCESS DOOR
ADD'L
ADDITIONAL
AFF
ABOVE FINISHED FLOOR
AFG
ABOVE FINISHED GRADE
AHU
AIR HANDLING UNIT
ALUM
ALUMINUM
AMP/AMPS
AMPERAGE
AP
ACCESS PANEL
ARCH
ARCHITECT
BC
BEADED COLLAR
BDD
BACKDRAFT DAMPER
BF
BELOW FLOOR
BHP
BRAKE HORSEPOWER
BLDG
BUILDING
BOD
BOTTOM OF DUCT
BOP
BOTTOM OF PIPE
BOT
BOTTOM
BS
BIRD SCREEN / BLACK STEEL
BTU
BRITISH THERMAL UNIT
BTUH
BRITISH THERMAL UNITS PER HOUR
CAP
CAPACITY
CBD
CALIBRATED BALANCING DAMPER
CC
CONTROLS CONTRACTOR
CD
CEILING DIFFUSER/CONDENSATE DRAIN
CDWR
CONDENSER WATER RETURN
CDWS
CONDENSER WATER SUPPLY
CFM
CUBIC FEET PER MINUTE
CHWR
CHILLED WATER RETURN
CHWS
CHILLED WATER SUPPLY
CLG
CEILING
COL
COLUMN
CONIC
CONCRETE
COND
CONDENSATE
CONN
CONNECT/CONNECTED/CONNECTION
CONT
CONTINUOUS/CONTINUATION
CONTR
CONTRACTOR
COORD
COORDINATE
COP
COEFFICIENT OF PERFORMANCE
CT
COOLING TOWER
CU
CUBIC/CONDENSER UNIT
CW
DOMESTIC COLD WATER/CONDENSER WATER
DB
DUCTBOARD/DRY BULB/DECIBEL
DDC
DIRECT DIGITAL CONTROL
DEFL
DEFLECTION
DEG
DEGREE/DEGREES
DIA
DIAMETER
DMPR
DAMPER
DN
DOWN
DOAS
DEDICATED OUTSIDE AIR SYSTEM
DWG
DRAWING
EXH
EXHAUST
EA
EACH/EXHAUST AIR
EAT
ENTERING AIR TEMPERATURE
EC
EGGCRATE GRILLE/END CAP/ELEC CONTRACTOR
EER
ENERGY EFFICIENT RATING
EF
EXHAUST FAN
EFF
EFFICIENCY
EL
ELEVATION
ELEC/ELECT
ELECTRICAL/ELECTRIC
EMCS
ENERGY MANAGEMENT CONTROL SYSTEM
ENT
ENTERING
EQUIP
EQUIPMENT
ESP
EXTERNAL STATIC PRESSURE
EWT
ENTERING WATER TEMPERATURE
EXIST/(E)
EXISTING
EXH
EXHAUST
F
FAHRENHEIT
FAC
FIRE ALARM CONTRACTOR
FD
FIRE DAMPER
FDC
FIRE DEPARTMENT CONNECTION
FF
FINISHED FLOOR
FIC
FURNISHED AND INSTALLED BY CONTRACTOR
FIO
FURNISHED AND INSTALLED BY OWNER
FLA
FULL LOAD AMPS
FLEX
FLEXIBLE
FLR
FLOOR
FOB
FLAT ON BOTTOM
FOIC
FURNISHED BY OTHERS,
INSTALLED BY CONTRACTOR
FOS
FLAT ON SIDE
FOT
FLAT ON TOP
FP
FIRE PROTECTION
FPM
FEET PER MINUTE
FSD
FIRE/SMOKE DAMPER
FT
FOOT/FEET
FUT
FUTURE
FV
FACE VELOCITY
G
GRILLE
GA
GAUGE/GALLON
GALV
GALVANIZED
GC
GENERAL CONTRACTOR
GPM
GALLONS PER MINUTE
GRID
GRILLE/REGISTER/DIFFUSER
GWB
GYPSUM WALL BOARD
HD
HEAD
HORIZ
HORIZONTAL
HP
HORSEPOWER
HR
HOUR
HSPF
HEATING SEASONAL PERFORMANCE FACTOR
HT
HEIGHT
HWTG
HIGH WALL TRANSFER GRILLE
HWR
HOT WATER RETURN
HWS
HOT WATER SUPPLY
HX
HEAT EXCHANGER
HZ
HERTZ
IBC
INTERNATIONAL BUILDING CODE
ICW
INDUSTRIAL COLD WATER
ID
INSIDE DIAMETER/DIMENSION
IE
INVERT ELEVATION
IEER
INTEGRATED ENERGY EFFICIENCY RATIO
IMC
INTERNATIONAL MECHANICAL CODE
IN
INCHES
IN WG
INCHES WATER GAUGE
IPLV
INTEGRATED PART LOAD VALUE
KW
KILOWATTS
LAT
LEAVING AIR TEMPERATURE
LB/LBS
POUND/POUNDS
LF/LIN FT
LINEAL FOOT/FEET
LPG
LIQUID PROPANE GAS
LPS
LOW PRESSURE STEAM
LVG
LEAVING
LWA
SOUND POWER RATING LEVEL (IN DB)
LWG
LOW WALL GRILLE
LWT
LEAVING WATER TEMPERATURE
MAX
MAXIMUM
MAU
MAKE UP AIR UNIT
MBH
1000 BRITISH THERMAL UNITS/HOUR
MCA
MINIMUM CIRCUIT AMPACITY
MD
MOTORIZED DAMPER
MFR
MANUFACTURER
MISC
MISCELLANEOUS
MIN
MINIMUM/MINUTE
MPS
MEDIUM PRESSURE STEAM
MT
MOUNT
MTD
MOUNTED
MUW
MAKE-UP WATER
NA
NOT APPLICABLE
NC
NORMALLY CLOSED/NOISE CRITERIA
NG/NGAS
NATURAL GAS
NIC
NOT IN CONTRACT
NO
NORMALLY OPEN/NUMBER
NPW
NON -POTABLE WATER
N-R
NON-RESIDENTIAL
OA/OSA
OUTSIDE AIR
OBD
OPPOSED BLADE DAMPER
OD
OUTSIDE DIAMETER/DIMENSION
PCF
POUNDS PER CUBIC FOOT
PD
PRESSURE DROP
PH
PHASE
POC
POINT OF CONNECTION
P/PRESS
PRESSURE
PSI
POUNDS PER SQUARE INCH
PSIG
POUNDS PER SQUARE INCH GAUGE
QTY
QUANTITY
R
RETURN GRILLE/RELOCATED/RETURN
RA
RETURN AIR
RD/RND
ROUND
REF
REFERENCE
REQ
REQUIRED
RESID
RESIDENTIAL
RF
RELIEF
RG
REFRIGERANT DISCHARGE GAS
RL
REFRIGERANT LIQUID
RPM
REVOLUTIONS PER MINUTE
RS
REFRIGERANT SUCTION
S
SUPPLY
SA
SUPPLY AIR
SAT
SATURATION/SUPPLY AIR TEMPERATURE
SD
SMOKE DETECTOR
S/D
SLIP & DRIVE CONNECTION
S_C
SEATTLE CODE
SEER
SEASONAL ENERGY EFFICIENCY RATING
SENS
SENSIBLE
SL
SOUND LINED
SM
SHEETMETAL
SPEC
SPECIFICATION
SO
SCREENED OPENING
SOG
SLAB ON GRADE
SP
STATIC PRESSURE
SF
SQUARE FEET
SS
STAINLESS STEEL
STRUC
STRUCTURAL
TA
TRANSFER AIR
TEMP
TEMPERATURE/TEMPORARY
TBD
TO BE DETERMINED
TOD
TOP OF DUCT
TOS
TOP OF STEEL/TOP OF SLAB
TOT
TOTAL
TSP
TOTAL STATIC PRESSURE
TSTAT
THERMOSTAT
TYP
TYPICAL
UH
UNIT HEATER
UNO
UNLESS NOTED OTHERWISE
V
VOLT
VA
VENTILATION AIR
VD
VOLUME DAMPER
VEL
VELOCITY
VERT
VERTICAL
VFD
VARIABLE FREQUENCY DRIVE
VOL
VOLUME
W
WRAPPED DUCT
WB
WET BULB
WG
WATER GAUGE
W/
WITH
W/0
WITHOUT
W/SF
WATTS PER SQUARE FOOT
WSEC
WASHINGTON STATE ENERGY CODE
�-CHWS/CHWRj
CHILLED WATER SUPPLY/RETURN
RL/RS----s
REFRIGERANT LIQUID/SUCTION
N G
NATURAL GAS
Z LPG
LIQUID PROPANE GAS
�--CDWS/CDWR-s
CONDENSER WATER SUPPLY/RETURN
z-HWS/HWR--S
HEATING WATER SUPPLY/RETURN
2- COND
CONDENSATE
2 FOV
FUEL OIL VENT
�--FOS/FORS
FUEL OIL SUPPLY/RETURN
zRDG
REFRIGERANT DISCHARGE GAS
MECHANICAL LEGEND
t10"X10"M RECT SUPPLY AIR DUCT
10"X10" UP/TOWARD
10"X10" RECT SUPPLY AIR DUCT
10"X L D DN/AWAY
10"X10" P1 RECT RETURN DUCT
10"X10" UP/TOWARD
10"X10" RECT RETURN DUCT
10"X10 DN/AWAY
t10"X10"M RECT EXHAUST
10"X10" UP/TOWARD
10"X10" RECT EXHAUST
10"X10" DN/AWAY
105 GD
10� ROUND DUCT - UP/TOWARD
10" o i
10 ROUND DUCT - DN/ AWAY
12"X10"O FLATOVAL DUCT - UP/ TOWARD
12"X10"O FLATOVAL DUCT - DN/ AWAY
10"0 o DUCT OVERLAP
10" o
BOOT TAP
10" o
10" o 45° TAP
10"0 VOLUME DAMPER
10��
1ONO i 1 CALIBRATED BALANCING DAMPER
RLD-
RISE(R) & DROP(D)
TRANSITION
TURNING VANES/SPLITTERS
DUCT MOUNTED SMOKE DETECTOR
BDD
BACK DRAFT DAMPER
FLEXIBLE DUCT
n� AIR FLOW (FORCED AIR)
�7
COMBINATION FSD
FIRE DAMPER
SMOKE DAMPER
MOTOR OPERATED DAMPER
0 0 o t
ACCESS DOORS
SOUND TRAP
FLEX CONNECTION
El 6"X 16"0
aSLa ACOUSTICALLY LINED DUCT
OD = OUTSIDE DIMENSIONS
SL = SOUND LINING (THICKNESS)
FABRIC DUCT
CLEARANCE
® SUPPLY AIR DIFFUSER
(WITH CORE BLANKOFF/ROTATE)
® CEILING EXHAUST AIR GRILLE
CEILING RETURN OR TRANSFER
AIR GRILLE
o SLOTTED DIFFUSER (PLAN VIEW)
Qx REVISION CLOUD & TRIANGLE
##"0 ROUND DUCT SYMBOL
##X##'O FLATOVAL DUCT SYMBOL
##° DEGREES SYMBOL
S POINT OF CONNECTION
CD1-100 GRID TAG IDENTIFIER = TYPE-CFM
8" 0 SIZE
(DT'STAT/TEMP SENSOR CARBON DIOXIDE
( HUMIDITY SENSOR SENSOR
sD SMOKE DETECTOR CO CARBON MONOXIDE
SP STATIC PRESSURE SENSOR SENSOR
OO OCCUPANCY SENSOR (D SENSOR
EXISTING DUCTWORK
DEMO DUCTWORK
WALL -MOUNTED GRILLE
PIPE ELBOW UP
o
PIPE ELBOW DN
DIRECTION OF FLOW
-
DIRECTION OF SLOPE DOWN
PLUG OR CAP
PRESS REDUCING ASSEMBLY
SOLENOID VALVE
PUMP
MECHANICAL GENERAL NOTES
1. WORK SHALL CONFORM TO APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2018 IBC, 201AWPiuc- V D
& SIMILAR YEAR WAC 296-104 BOILER RULES. JE
2. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY N S MUST BE
3. LOCATION AND DETAILS OF EQUIPMENT, DUCT ROUTING AND CONNECTIONS ARE APPROXIMATE. COORDINATE FINAL LO 0 WITI�
OTHER TRADES. INSTALL IN ACCORDANCE WITH APPROVED SUBMITTALS AND DETAIL DRAWINGS WHEN APPLICABLE.
ON JOB SITE
4. VERIFY EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH WORK.
5. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, DETAILS SHALL BE THE
AS FOR OTHER SIMILAR WORK. IF ADDITIONAL QUESTIONS REMAIN, CONTACT THE ENGINEER PRIOR TO PROCEEDING.
6. ALL STRUCTURAL OPENINGS AND PLATFORMS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR UNO. ALL WORK SUBJECT
7. DUCT SEALING AND CONSTRUCTION TO MEET SMACNA AND ENERGY CODE REQUIREMENTS. UNO: LOW PRESSURE D CTWORK DOWN�'fR'EAT1�d1=`bAV BOXES,
CONSTANT VOLUME AC SYSTEMS, TOILET EXHAUSTS, ETC.) TO MEET 2" C,ONSTRUCTION CLASS WITH SEAL CLASS C. EDIU�P fe17I�ONR f OR
(UPSTREAM >OF WI H BOXES,
CLASS A). DUCT
CTCITY EXHAUSTS,
IN ETC.)
WITH MEET
DAM EREDT PENETRATIONS ONSCLASS
TO MEET SEAL
6" CONTT U kamoll"_V�Ij _OUTDOOR INSTALLED SUPPLY & RETURN DUCTS TO HAVE SEAL CLASS A. C
8. ALL CEILING DIFFUSERS ARE 4-WAY THROW UNLESS NOTED OTHERWISE.
9. ALL DUCT DIMENSIONS ARE OUTSIDE DIMENSIONS BEFORE SOUND LINING HAS BEEN ACCOUNTED FOR (SOUND LINING @ 1", UNO)
10. OUTSIDE AIR INTAKES ON ALL AIR HANDLING UNITS SHALL BE 10 FEET AWAY FROM ANY VENTS, STREETS, LOADING DOCK,
NEIGHBORING LOT LINES & FUEL BURNING EQUIPMENT OR 3 FEET BELOW OR 25' ABOVE ANY CONTAMINANT SOURCE WITHIN 10 FEET.
11. ALL AIR ECONOMIZERS SHALL BE CAPABLE OF THE FOLLOWING PER C403.3.1 & C403.2.4.7:
-0% TO 100% OF THE DESIGN SUPPLY AIR WITH FAULT DETECTION & DIAGNOSTIC REPORTING.
-CONTROLLED BY A CONTROL SYSTEM DETERMINING IF THE OUTSIDE AIR CAN MEET PART OR ALL OF THE BUILDING COOLING LOADS.
-INTEGRATED TO PROVIDE PARTIAL COOLING EVEN WHEN MECHANICAL COOLING IS REQUIRED.
12. OUTSIDE AIR INTAKE, RELIEF, AND EXHAUST OPENINGS SHALL BE EQUIPPED WITH MOTORIZED CLASS 1 LOW LEAK (<4 CFM/SF @ 1" WG) DAMPERS (OR GRAVITY
PER EXCEPTIONS IN C403.2.4.3) DAMPERS WHICH CLOSE AUTOMATICALLY WHEN SYSTEM IS OFF OR UPON POWER FAILURE, UNO FOR SMOKE CONTROL SYSTEM
OPERATION.
13. THE CONTROL SYSTEM SHALL MEET C403 AND BE PROGRAMMABLE, CAPABLE OF BEING SET FOR DIFFERENT DAY TYPES PER WEEK,
DEADBAND SETTING OF AT LEAST 57 (107 FOR RESIDENNfROL
, BETWEEN THE HEATING AND COOLING SETPOINTS AND
SETBACK TEMPERATURES WITH OPTIMAL START CONTROL. SYSTEM SHALL INCLUDE A MICROPROCESSOR AND BE CAPABLE OF VARYING FLOWS
AND RESETTING SUPPLY AIR & WATER TEMPERATURES BY REPRESENTATIVE BUILDING LOADS WHERE REQUIRED IN C403.4.
14. WHERE REQUIRED BY C408, RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER
WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER THE ENERGY CODE. AN OPERATING MANUAL AND MAINTENANCE MANUAL
SHALL BE PROVIDED TO THE BUILDING OWNER. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCING REPORT
SHALL BE PROVIDED TO THE OWNER. HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE
WITH APPROVED PLANS. A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL
BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY. A COMPLETE FINAL COMMISSIONING REPORT OF
TEST PROCEDURES AND RESULTS SHALL BE PROVIDED TO THE OWNER.
15. MECHANICAL SYSTEMS SHALL COMPLY WITH SEISMIC RESTRAINT REQUIREMENTS OF THE BUILDING CODE, SMACNA AND ASCE 7. ALL LIFE
SAFETY OR HAZARDOUS MATERIAL RELATED SYSTEMS SHALL BE DEEMED AN Ip=1.5 FOR RESTRAINT METHODS OR AS NOTED ON THE DRAWINGS.
REFER TO CODES FOR INSTALLATION REQUIREMENTS AND EXCEPTIONS BASED ON SIZING, WEIGHTS AND MOUNTING HEIGHTS.
16. PROVIDE EARTHQUAKE RESTRAINTS FOR HVAC EQUIPMENT AS REQUIRED BY SMACNA SEISMIC RESTRAINT MANUAL, SEISMIC HAZARD B.
WIRES FOR CEILING SYSTEM ETC. SHALL NOT BE HUNG OFF HVAC EQUIPMENT OR HVAC EQUIPMENT SUPPORTS.
17. PROVIDE FIRE AND COMBINATION FIRE/SMOKE DAMPERS WHERE SHOWN ON PLANS AND WHERE REQUIRED PER CODE, AT 1-1/2 HR RATING UNO.
18. ALL PIPING PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH AN UL APPROVED FIRE CAULKING.
ALL MATERIALS EXPOSED WITHIN PLENUMS SHALL BE NON-COMBUSTIBLE OR SHALL BE UL LISTED AND LABELED FOR INSTALLATION IN PLENUMS OR
AS HAVING A FLAME SPREAD INDEX <- 25 AND A SMOKE -DEVELOPED INDEX OF <- 50.
19. SMOKE DETECTORS PROVIDING AUTOMATIC SHUTDOWN SHALL BE PROVIDED IN THE RETURN AIR, PER MECH CODE, SUCH AS HVAC
EQUIPMENT DELIVERING (NOT EXHAUST) >2000 CFM (INCLUDING MULTIPLE UNITS DUCTED INTO COMMON DISTRIBUTION OR RETURN, WITH A TOTAL
SUPPLY >2000 CFM) OR EACH STORY OF RETURN SYSTEMS OVER 15,000 CFM IN A MULTI -STORY INSTALLATION, NOT IN SYSTEMS SERVING SINGLE
ROOMS/SPACES. SMOKE DETECTORS SHALL BE FIC (ELEC) UNO. POWER -WIRING AND INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR
AS APPLICABLE. VAV BOX (WITH FAN) SHUTDOWN CAN BE THROUGH CONTROLS SYSTEM.
20. ARCHITECTURAL ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY GC AT ALL CONCEALED EQUIPMENT AND DEVICE LOCATIONS, UNLESS NOTED OTHERWISE.
21. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR.
MOTOR EFFICIENCIES TO MEET OR EXCEED CODE MINIMUM.
22. FOR ALL "SEALED AIR TGHT" OR PRESURZEDUSE SECTION 909.5I OF THE 2015 SBCI FOR SMAX AHAFTSLLOWABLE ROOMS �LEEAKAGE AREA,TFOLLOW NG D PRESSURE/EMERATURETHE GUIDELINES HUMIDITY NTFOR TIGHT OLLED ROOSTAIRTSHAFTLCONISTRUCTION.00CUR:
-ALL VERTICAL JOINTS, CORNERS AND WALL TRACKS (TOP AND BOTTOM) SHALL BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT (BY
GC)
-ANY FLOOR DECKING PERPENDICULAR TO THE CONSTRUCTION SHALL BE CAULKED (BY GC). FILLING WITH ROCK WOOL IS NOT ACCEPTABLE.
-ANY PENETRATIONS OF THE CONSTRUCTION (DUCTWORK, CONDUIT, PIPING, ...) SHALL BE SEALED ON BOTH SIDES
-ALL DOORS SHALL BE PROVIDED WITH TIGHT FITTING GASKETS AND THRESHOLD SWEEPS, AND OPEN AGAINST THE DIRECTION OF PRESSURE.
-IN ADDITION TO ABOVE, ROOM ENVELOPE TO HAVE VAPOR BARRIER FOR HUMIDITY CONTROLLED ROOMS
-ROOM ENVELOPE TO BE INSULATED (R-11 MIN) IF TEMPERATURE DIFFERENCE EXCEEDS 10°F TO AJACENT AREAS
23. ALL ADHESIVES, SEALANTS, PAINTS AND COATINGS USED DURING THE INSTALLATION/FINISH WORK SHALL MEET THE LEED REQUIREMENTS FOR IEQ.
24. MAXIMUM STANDARD LENGTH OF FLEXIBLE DUCT SHALL BE BUILDING STANDARDS OR 12' MAX; UP TO 25' MAXIMUM LENGTH IS ACCEPTABLE IF;
FLEX DUCT (UL-181 TESTED & NOT "CONNECTOR") IS USED, DUCT 0 IS INCREASED BY 1 NOMINAL SIZE & BENDS DO NOT EXCEED 235° TOTAL.
REFER TO INSTALLATION DETAILS FOR SUPPORT REQUIREMENTS. FLEXIBLE DUCT FLAME SPREAD RATING SHALL BE < 25 AND SMOKE DEVELOPED RATING SHALL
BE < 50. USE THERMAFLEX MODEL G-KM FOR LOW AND MEDIUM PRESSURE APPLICATIONS OR APPROVED EQUAL.
25. ELECTRICAL METERING OF SYSTEMS AS REQUIRED BY ENERGY CODE SECTION C409 IS BY ELECTRICAL. THE ELECTRICAL DESIGN & CONTRACTOR TEAM
WILL FURNISH THE NECESSARY ELECTRICAL DISTRIBUTION AND METERING COMPONENTS - SEE ELECTRICAL DRAWINGS. THE MECHANICAL CONTRACTOR
WILL FURNISH A BUILDING MANAGEMENT SYSTEM CAPABLE OF COLLECTING AND STORING THE INFORMATION WITH A VISIBLE DISPLAY/NOTIFICATION
READILY ACCESSIBLE TO OPERATION AND MANAGEMENT PERSONNEL AS REQUIRED.
26. THE PROJECT TEAM IS COLLECTIVELY RESPONSIBLE FOR COMPLIANCE WITH APPENDIX D, "RENEWABLE ENERGY SYSTEMS." AS WELL AS C406 "ADDITIONAL ENERGY
PACKAGE OPTIONS" AS APPLICABLE AND AS COORDINATED DURING DESIGN WITH DESIGN/CONSTRUCTION TEAM.
MINIMUM DUCT INSULATION LAST UPDATED 07/11/16
DUCT TYPE
DUCT LOCATION (IN HEATED AND MECHANICALLY COOLED DUCT SYSTEM)
INSULATION
R-VALUE
REMARKS
SUPPLY & RETURN
NOT WITHIN CONDITIONED SPACE: OUTSIDE BUILDING
R-8
1,2,3
OUTSIDE AIR
WITHIN CONDITIONED SPACE: INSIDE BUILDING
SEE NOTES 4 & 5
1,2,3,4,5
SUPPLY & RETURN
NOT WITHIN CONDITIONED SPACE: INSIDE BUILDING
R-6
1,2
SUPPLY AIR
<550 OR > 1050
WITHIN CONDITIONED SPACE
R-3.3
1,2
1 REFER TO C403.2.8 FOR FURTHER REQUIREMENTS & ALSO R403 FOR RESIDENTIAL INSTALLATIONS
2 INSULATED COOLED DUCTS REQUIRED A VAPOR RETARDER (PERM < 0.5) AND SEALED JOINTS
3 WEATHERPROOF BARRIER REQUIRED AROUND DUCTWORK TO MAINTAIN WATER TIGHTNESS
4 INSULATE OUTSIDE AIR DUCTS TO BUILDING EXTERIOR WALL LEVEL PER ENERGY CODE SECTION: C403.2.8.1 UNTIL
CONNECTED TO EQUIPMENT SERVED OR TO THE CODE REQUIRED SHUTOFF DAMPER (AND Z" THICK INSULATION MIN.
TO PREVENT CONDENSATION ON DUCTS IN PLENUM UP TO THE HEATING OR COOLING EQUIPMENT)
5 R-7 CAN BE USED IN LIEU OF BUILDING ENVELOPE INSULATION LEVEL IF: DEDICATED OUTSIDE AIR SYSTEM AND <2,800 CFM SUPPLY AIR
MINIMUM PIPE INSULATION LAST UPDATED: 07/11/16
FLUID DESIGN
INSULATION CONDUCTIVITY
NOMINAL PIPE DIAMETER (INCH)
OPERATING
TEMP OF
CONDUCTIVITY
RANGE
MEAN TEMP
RATING `
<1
1 TO
<1-1/2
1-1/2 TO
<4
4 TO
<8
>8
HEATING SYSTEMS (STEAM, CONDENSATE, HYDRONIC
HOT WATER, DOMESTIC HOT WATER & RECIRC)
>350
0.32-0.34
250
4.5
5.0
5.0
5.0
5.0
251-350
0.29-0.32
200
3.0
4.0
4.5
4.5
4.5
201-250
0.27-0.30
150
2.5
2.5
2.5
3.0
3.0
141-200
0.25-0.29
125
1.5
1.5
2.0
2.0
2.0
105-140
0.21-0.28
100
1.0
1.0
1.5
1 1.5
1 1.5
DOMESTIC COLD WATER AND HORIZONTAL RAIN LEADERS TO FIRST VERTICAL RAIN LEADER (TO PREVENT CONDENSATION)
N/A
0.21-0.27
75
0.5
0.5
0.5
0.5
0.5
COOLING SYSTEMS (CHILLED WATER, BRINE AND REFRIGERANT, WATERSIDE ECONOMIZER SYSTEMS)**
40-60
0.21-0.27
75
0.5
0.5
1.0
1.0
1.0
<40
0.20-0.26
75
0.5
1.0
1.0
1.0
1.5
DRAWING INDEX
SHEET NO.
SHEET TITLE
CURRENT
REVISION
M0.00
COVER SHEET - HVAC
M0.01
SCHEDULE SHEET - HVAC
M1.01
SITE PLAN - HVAC
M2.01
PARTIAL 1ST FLOOR PLANS - HVAC
City Of Edmonds
Building Department
---------- ---------
Work MECHNICAL
----------------------------------------
Address
20903 70TH AVE W
Owner COMPASSHEALTH
----------------------
Approved Date 6-2-2021
BuildingOfficial:Eri&C 4-fer
27042000302700
APPROVED BY PLANNING
w'111�
May 27 2021
3)
Hermanson
Building Today, Defining Tomorrow
Hermanson Company LLP
1221 2nd Avenue North
Kent, Washington 98032
Tel: (206) 575-9700
Fax: (206) 575-9800
www.hermanson.com
Contractor Reg #: HERMACLO05BJ
SPLIT
SYSTEMS
COMPASSHEALTH AURORA HOUSE
20903 70TH AVE. W.
EDMONDS, WA 98026
LEGAL DESCRIPTION
SEC 20 TWP 27 RGE 04 TH PTN E1/2 SE1/4 SW1/4 DAF COM AT NE COR
OF SD SE1 /4 SW1 /4 TH S02*46 23E ALG E LN OF SD SUBDIV 3OFT TH
S89*22 07W 672.13FT M/L TAP 1 OFT E OF W LN E1 /2 SE1 /4 SW1 /4 TH
S02*33 23EALG E LN OF PRTY CONVYD TO SNO CO REC AF NO 1399049
DIST 357.42FT TAP THAT BEARS S89*22 07W FR SW COR LOT 12 PLAT OF
HOYT ACRES TPB TH N89*22 07E 223.23FT TAP THAT BEARS NO2*33 23W
FR SW COR LOT 7PLAT OF HOYT ACRES TH S02*33 23E 120FT TH S89*22
07W 223.23FT TAP 1 OFT E OF W LN OF SD E1 /2 SE1 /4 SW1 /4 TH NO2*33
23W 120FT TO TPB EXC W 20FT THOF (AURORA HSE EXEMPT WA ST
REG#09380-003)
cN�ooOR A,.
�SSfoNAL E�`G
May 18, 2021
Revisions
a Lynnwood rya
`11i ul Cr
EDMONDS BOWL 4 A 3
Puget Sound - 2DathStswCedar Valley £
9 Edmonds ALDERYI
arCh Way
20903 70th Ave W, Mew
EDMONDS WATERFRONT _ Edmonds, WA 98026 I'm St SW
"�^• -'4th St SW
223;t. i; �;v - MELODY HILL
Woodway m
Esperance EASTTERRACE Brier
ze
FRUITLAND ACRES Terrace $ ?
Firdale Abbey
�T A View
__________ _________ ------------Memorial_
� 2
N 236tr St N �QD,h St
BALLINGER -
Richmond Beach a - F 1 e
HILLWOOD-
crun..vc
o� �0M
VICINITY MAP
NO SCALE
05/14/21 WSS ISSUE FOR PERMIT
ti
a
No. Date By Description
Z4
SITE MAP
NO SCALE
FOR CITY USE:
0
M
�
A
z
Q
z
ti
^
a
RECEIVED
May 19 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
BLD2021-0693
Design Team
Design WSS
Drawn FVP
Checked DTN
Pre -Construction Number 14-21-19350
Construction Number
Issue Date 05/14/21
COVER
SHEET
- HVAC
M0000
ISSUE FOR PERMIT
NOTE:
* NOT REQUIRED FOR STRAINERS, CONTROL VALVES & BALANCING VALVES ASSOCIATED WITH PIPING 1" OR LESS IN DIA.
** TYPICAL CONDENSER WATER PIPE IN NON -ECONOMIZER SYSTEMS IS NOT INSULATED SEE R403 FOR RESIDENTIAL INSTALLATIONS.
DEMO SPLIT SYSTEM INDOOR FAN COIL UNIT SCHEDULE LAST UPDATED: 051121
UNIT
TAG
LOCATION
SERVES
BASIS OF
DESIGN
ASSOCIATED
CONDENSER
SUPPLY
CFM
OSA
CFM
ESP
IN WG
MAX REFR
FT HT
HEATER
KW
ELECTRICAL
SOUND
dBA
WEIGHT
LBS
REMARKS
MCA
V PH
FCU-102
WALL
DATA ROOM
MITSUBISHI MSY-D30NA
CU-SOS
-
-
0.00
-
NA
1.0
208-230/1
-
40
1
REMARKS:
1 DEMO
DEMO SPLIT SYSTEM OUTDOOR CONDENSING UNIT SCHEDULE LAST UPDATED: 05/11/21
UNIT
TAG
LOCATION
AREA
SERVED
BASIS
OF DESIGN
ASSOCIATED
FAN COIL UNIT
COOLING
CAPACITY BTUH
HEATING
CAPACITY
ELECTRICAL
SOUND
dBA
WEIGHT
LBS
REMARKS
TOTAL
I SENS.
SEER
I BTUH
HSPF COP
MCA
V PH
CU-101
AT GRADE
DATA 101
MITSUBISHI MUY-D30N
FCU-102
32000
26240
-
N/A
N/A
21.0
208-230/1
-
126
REMARKS:
1 DEMO
DEMO SPLIT SYSTEM INDOOR FAN COIL UNIT SCHEDULE LAST UPDATED: 05/11/21
UNIT
TAG
LOCATION
SERVES
BASIS OF
DESIGN
ASSOCIATED
CONDENSER
SUPPLY
CFM
OSA
CFM
ESP
IN WG
MAX REFR
LINE FT
HEATER
WATTS
ELECTRICAL
SOUND
dBA
WEIGHT
LBS
REMARKS
MCA
V PH
FCU-101
CEILING
KITCHEN
SANYO TWH3672R
HP-101
-
0.00
-
NA
1.0
208-230/1
-
90
1
REMARKS:
1 DEMO
DEMO SPLIT SYSTEM OUTDOOR HEAT PUMP UNIT SCHEDULE LAST UPDATED: 05/11/21
UNIT
TAG
LOCATION
I AREA
SERVED
BASIS
OF DESIGN
ASSOCIATED
FAN COIL
I COOLING CAPACITY BTUH
I HEATING CAPACITY
I ELECTRICAL
SOUND
dBA
WEIGHT
LBS
REMARKS
TOTAL
SENS
SEER/EER
BTUH
HSPF/COP
MCA
V/PH
HP-101
AT GRADE
I KITCHEN
SANYO CH3672R
FCU-101
36,000
27,000
-
37,000
-
21.0
208-230/1
-
-
1
REMARKS:
1 DEMO
REPLACEMENT SPLIT SYSTEM INDOOR FAN COIL UNIT SCHEDULE LAST UPDATED: 05/11/21
UNIT
TAG
LOCATION
SERVES
BASIS OF
DESIGN
ASSOCIATED
CONDENSER
SUPPLY
CFM
OSA
CFM
ESP
IN WG
MAX REFR
FT / HT
HEATER
KW
ELECTRICAL
SOUND
dBA
WEIGHT
LBS
REMARKS
MCA
V/PH
FCU-102
WALL
DATA ROOM
DAIKIN FTX30NVJU
CU-101
512/572/727/890
NA
0.00
98' / 65'
NA
17.0
208-230/1
37-40-47-53
38
1-11
GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS (ELECTRICAL, WEIGHT, SIZE, ETC...) WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION; FIELD COORDINATE FINAL LOCATION & INSTALL
PER MANUFACTURERS REQUIREMENTS
1 ELECTRICAL CONTRACTOR TO PROVIDE SCCR PROTECTION FOR EQUIPMENT AS REQUIRED BY NATIONAL ELECTRICAL CODE.
MANUFACTURER TO PROVIDE SCCR LISTING (5 KAIC MINIMUM) INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE.
2 SINGLE CONDENSING UNIT FOR EACH INDOOR FAN COIL UNIT. PROVIDE WITH WALL -MOUNTED WIRELESS PROGRAMMABLE T'STAT, REFER TO MFG'S REQUIREMENTS FOR REFRIGERANT PIPE SIZES
3 INDOOR UNIT POWERED FROM OUTDOOR UNIT BY ELECTRICAL CONTRACTOR
4 REFRIGERANT: R-410A. PROVIDE ADDITIONAL CHARGING OF LINES AS REQUIRED FOR LONG LINE LENGTH APPLICATIONS
5 PROVIDE WALL MOUNTED FCU CONDENSATE DRAIN PUMP (GOBI 230-XL - 2.5 GPH @ 10 FT LIFT & < 100 FT HORIZ, 115V/1 PH @ 32W, 5 LBS). TERMINATE DRAIN LINE IN HUB DRAIN BY NEAREST SINK
TAILPIECE OR INDIRECT AT NEAREST FLOOR DRAIN
6 OUTSIDE AIR INDICATES MINIMUM CFM PER ASHRAE. TAB WORK MUST MEET OR EXCEED INDICATED QUANTITY.
7 ECONOMIZER EXEMPT PER 2018 WSEC C403.5 EXCEPTION 11 (UNIT IS 15% MINIMUM HIGHER EFFICIENCY THAN THE 13 SEER REQUIREMENT IN TABLE C403.3.2(1)A)
8 UNIT TO BE CONFIGURED TO PROVIDE LOW AMBIENT COOLING AT BELOW 240F
9 PROVIDE FILTERS AT RETURN AIR OPENINGS OF NEW AND/OR EXISTING UNITS, UPSTREAM OF ANY HEAT EXCHANGER OR COILS PER SMC / IMC 605
10 PROVIDE SEISMIC BRACING PER ACSE 7, UNLESS: UNIT IS WALL MOUNTED OR <20 LBS OR IS RIGID MOUNTED INLINE WITH DUCT (NO FLEX) AND <75 LBS
11 HEATING & COOLING FANS/PUMPS SHALL SHUT OFF WHEN THERE IS NO CALL FOR HEATING AND COOLING IN THE ZONE PER WSEC 2018 C403.3.5.2, EXCEPT IF HEATING/COOLING FANS <0.12W/CFM
SPLIT SYSTEM OUTDOOR CONDENSING UNIT SCHEDULE LAST UPDATED: 01 23 20
UNIT
TAG
LOCATION
AREA
SERVED
BASIS
OF DESIGN
ASSOCIATED
FAN COIL UNIT
COOLING CAPACITY BTUH
HEATING CAPACITY
ELECTRICAL
SOUND
dBA
WEIGHT
LBS
REMARKS
TOTAL
SENS.
SEER
BTUH
HSPF/COP
MCA
V/PH
CU-R01
AT GRADE
DATA ROOM
DAIKIN RK30NMVJUA
FCU-102
31,400
21,030
17.5
N/A
N/A
17.0
208-230/1
56
133
1-9
GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS (ELECTRICAL, WEIGHT, SIZE, ETC...) WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION; FIELD COORDINATE FINAL LOCATION & INSTALL
PER MANUFACTURERS REQUIREMENTS
1 ELECTRICAL CONTRACTOR TO PROVIDE SCCR PROTECTION DIRECTION FOR EQUIPMENT AS REQUIRED BY LATEST APPROVED VERISON OF THE NATIONAL ELECTRICAL CODE, PRIOR TO ORDER.
MANUFACTURER TO PROVIDE SCCR LISTING (5 KAIC MINIMUM OR PER ELECTRICAL CONTRACTOR CALCULATION) INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE-
2 SPLIT SYSTEM UNITS REQUIRE DISCONNECT AT THE CONDENSING UNIT BY ELECTRICAL CONTRACTOR
3 INVERTER DRIVEN COMPRESSOR, TEST CONDITIONS BASED ON AHRI 210/240
4 REFRIGERANT: R-410A. PROVIDE ADDITIONAL CHARGING OF LINES AS REQUIRED FOR LONG LINE LENGTH APPLICATIONS
5 SINGLE CONDENSING UNIT FOR EACH INDOOR FAN COIL UNIT. REFER TO MFG'S REQUIREMENTS FOR REFRIGERANT PIPE SIZES FOR EACH UNIT CONNECTION - CONFIRM CONTROL WIRE
GAUGE (14 OR 16 AWG) WITH SUBMITTALS PRIOR TO INSTALLATION TO INDOOR UNIT
6 PROVIDE WITH WIND BAFFLE AND LOW AMBIENT OR HEAD PRESSURE CONTROL SUITABLE FOR LOW AMBIENT COOLING
7 ECONOMIZER EXEMPT PER 2018 WSEC C403.5 EXCEPTION 11 (UNIT IS 15% MINIMUM HIGHER EFFICIENCY THAN THE 13 SEER REQUIREMENT IN TABLE C403.3.2(1)A)
8 UNIT TO BE CONFIGURED TO PROVIDE LOW AMBIENT COOLING AT BELOW 240F
9 PROVIDE WITH AIREX PROSYSTEM KIT E-FLEX GUARD OR APPROVED EQUAL WHEN EXPOSED TO WEATHER IN COLOR TO MATCH SURROUNDING AREAS (BLACK OR WHITE) COLOR FROM EXTERIOR
PENETRATION TO CONDENSING UNIT CONNECTION IN COMPLIANCE WITH WSEC C403.10.3
REPLACEMENT SPLIT SYSTEM INDOOR FAN COIL UNIT SCHEDULE LAST UPDATED: 05 11 21
UNIT
TAG
LOCATION
SERVES
BASIS OF
DESIGN
ASSOCIATED
CONDENSER
SUPPLY
CFM
OSA
CFM
ESP
IN WG
MAX REFR
LINE FT
HEATER
WATTS
ELECTRICAL
SOUND
dBA
WEIGHT
LBS
REMARKS
MCA
V PH
FCU-101
CEILING
KITCHEN
DAIKIN FXHQ36MVJU
HP-101
670/830
-
0.00
65'
NA
1.4
208-230/1
46
90
1-13
GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS (ELECTRICAL, WEIGHT, SIZE, ETC...) WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION; FIELD COORDINATE FINAL LOCATION & INSTALL PER
MANUFACTURERS REQUIREMENTS
1 ELECTRICAL CONTRACTOR TO PROVIDE SCCR PROTECTION FOR EQUIPMENT AS REQUIRED BY NATIONAL ELECTRICAL CODE.
MANUFACTURER TO PROVIDE SCCR LISTING (5 KAIC MINIMUM) INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE.
2 SINGLE CONDENSING UNIT FOR EACH INDOOR FAN COIL UNIT. PROVIDE WITH WALL -MOUNTED WIRELESS PROGRAMMABLE T'STAT, REFER TO MFG'S REQUIREMENTS FOR REFRIGERANT PIPE SIZES
3 INDOOR UNIT POWERED FROM OUTDOOR UNIT BY ELECTRICAL CONTRACTOR
4 REFRIGERANT: R-410A. PROVIDE ADDITIONAL CHARGING OF LINES AS REQUIRED FOR LONG LINE LENGTH APPLICATIONS
5 PROVIDE WALL MOUNTED FCU CONDENSATE DRAIN PUMP (GOBI 230-XL - 2.5 GPH @ 10 FT LIFT & < 100 FT HORIZ, 115V/1PH @ 32W, 5 LBS). TERMINATE DRAIN LINE IN HUB DRAIN BY NEAREST SINK
TAILPIECE OR INDIRECT AT NEAREST FLOOR DRAIN
6 PROVIDE PLENUM RATED OVERFLOW SHUT-OFF DEVICE CONFORMING TO UL-508 (I.E. RECTORSEAL SS2AP) IN LIEU OF SECONDARY DRAIN PAN
7 OUTSIDE AIR INDICATES MINIMUM CFM PER ASHRAE. TAB WORK MUST MEET OR EXCEED INDICATED QUANTITY.
8 ECONOMIZER EXEMPT PER 2018 WSEC C503.4.3 (SPLIT SYSTEM IS < 60,000 BTUH, AND +10% MORE EFFICIENT THAN THE 13 SEER REQUIREMENT IN TABLE C403.3.2(1)A)
9 HEAT PUMPS SHALL UTILIZE COMPRESSION HEATING AS FIRST STAGE OF HEAT AND AUXILIARY ELECTRIC HEAT SHALL NOT OPERATE ABOVE 40°F.
10 PROVIDE FILTERS AT RETURN AIR OPENINGS OF NEW AND/OR EXISTING UNITS, UPSTREAM OF ANY HEAT EXCHANGER OR COILS PER IMC 605
it PROVIDE SEISMIC BRACING PER ACSE 7, UNLESS: UNIT IS WALL MOUNTED OR <20 LBS OR IS RIGID MOUNTED INLINE WITH DUCT (NO FLEX) AND <75 LBS
12 PROVIDE WITH AIREX PROSYSTEM KIT E-FLEX GUARD OR APPROVED EQUAL WHEN EXPOSED TO WEATHER IN COLOR TO MATCH SURROUNDING AREAS (BLACK OR WHITE) COLOR FROM EXTERIOR
PENETRATION TO CONDENSING UNIT CONNECTION IN COMPLIANCE WITH WSEC C403.2.9.1
13 HEATING & COOLING FANS/PUMPS SHALL SHUT OFF WHEN THERE IS NO CALL FOR HEATING AND COOLING IN THE ZONE PER WSEC 2018 C403.3.5.2, EXCEPT IF HEATING/COOLING FANS <0.12W/CFM
REPLACEMENT SPLIT SYSTEM OUTDOOR HEAT PUMP UNIT SCHEDULE LAST UPDATED: 05/11/21
UNIT
TAG
LOCATION
AREA
SERVED
BASIS
OF DESIGN
ASSOCIATED
FAN COIL
COOLING CAPACITY BTUH
HEATING CAPACITY
ELECTRICAL
SOUND
dBA
I WEIGHT
LBS
REMARKS
TOTAL
SENS
SEER/EER
BTUH
HSPF/COP
MCA
V/PH
HP-101
AT GRADE
KITCHEN
DAIKIN RXTQ36TAV
FCU-101
34,200
25,650
18 / -
37,000
10.3 / -
16.5
208-230/1
58
172
1-6
GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS (ELECTRICAL, WEIGHT, SIZE, ETC...) WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION; FIELD COORDINATE FINAL LOCATION & INSTALL PER
MANUFACTURERS REQUIREMENTS
1 ELECTRICAL CONTRACTOR TO PROVIDE SCCR PROTECTION DIRECTION FOR EQUIPMENT AS REQUIRED BY LATEST APPROVED VERISON OF THE NATIONAL ELECTRICAL CODE, PRIOR TO ORDER.
MANUFACTURER TO PROVIDE SCCR LISTING (5 KAIC MINIMUM OR PER ELECTRICAL CONTRACTOR CALCULATION) INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE.
2 SPLIT SYSTEM UNITS REQUIRE DISCONNECT AT THE CONDENSING UNIT BY ELECTRICAL CONTRACTOR
3 INVERTER DRIVEN COMPRESSOR, TEST CONDITIONS BASED ON AHRI 210/240
4 SINGLE CONDENSING UNIT FOR EACH INDOOR FAN COIL UNIT. REFER TO MFG'S REQUIREMENTS FOR REFRIGERANT PIPE SIZES FOR EACH UNIT CONNECTION, WIND BAFFLE, LOW AMBIENT
OR HEAD PRESSURE CONTROL SUITABLE FOR LOW AMBIENT COOLING - ADDITIONALLY, CONFIRM CONTROL WIRE GAUGE (14 OR 16 AWG) WITH SUBMITTALS PRIOR TO INSTALLATION TO INDOOR UNIT
5 REFRIGERANT: R-410A. PROVIDE ADDITIONAL CHARGING OF LINES AS REQUIRED FOR LONG LINE LENGTH APPLICATIONS
6 ECONOMIZER EXEMPT PER 2018 WSEC C503.4.3 (SPLIT SYSTEM IS < 60,000 BTUH, AND +10% MORE EFFICIENT THAN THE 13 SEER REQUIREMENT IN TABLE C403.3.2(1)A)
FOR CITY USE:
RECEIVED
May 19 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
rir
Hermanson
Building Today, Defining Tomorrow
Hermanson Company LLP
1221 2nd Avenue North
Kent, Washington 98032
Tel: (206) 575-9700
Fax: (206) 575-9800
www.hermanson.com
Contractor Reg #: HERMACLO05BJ
SPLIT
SYSTEMS
COMPASSHEALTH AURORA HOUSE
20903 70TH AVE. W.
EDMONDS, WA 98026
c��ODOk',"
NO,��FGISTERV
SSION
May 18, 2021
Revisions
05/14/21 WSS ISSUE FOR PERMIT
No. Date By Description
Design Team
Design WSS
Drawn FVP
Checked DTN
Pre —Construction Number 14-21-19350
Construction Number
Issue Date 05/14/21
SCHEDULE
SHEET
- HVAC
WIT [I) to] I
ISSUE FOR PERMIT
PROPERTY LINE PROPERTY LINE
13' TO NEAREST PROPERTY LINE
I I
CU-101 I'
II II
I II
I II
I II
--- ------ IL_----------------------------------------------- -
---------------------------------------------------------- -
r
I r
r � I
II II
I ii ii I
II II
II II
II II
II II
II II
II II
II II
II II
II II
I II II I
II II
II II
II II
II II
II ------ �� II
I I I� -----i I I
II II II II
II I� II II
II II II
I I L�1 I I
� I I
L--------------JI IL-----------� IL J
L-----————————---J-----------
�I-------------------------------------J
II II
II
II II
II II
II II
II II
II II
1, II
II I�
II r -
I J r— II
------
L------------------- @95' TO PROPERTY LINE I
I I
,I I
,I II
r J I---J
II
,7_j II
II II
I II �I I
II
II II
II II
II II
II II
II II
II II
II II
II II
II
LL II
L-------
L------- --------
II II
II II
�I II
II II
II II
II II
II II
II II
I II II I
II II
II Il
IL JI
L J
1
I I
I I
I I
I I
I I
I I
I I
I I
PROPERTY LINE PROPERTY LINE
BLD2021-0693
Zone Corner Flag
Setbacks: Required Actual
Front
Sides
Rear
Other
Height
�1
oN C o�
� A
z SITE PLAN - HVAC
{
SCALE: 1/8" = 1'-0"
ti
FOR CITY USE:
RECEIVED
May 19 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Hermanson
Building Today, Defining Tomorrow
Hermanson Company LLP
1221 2nd Avenue North
Kent, Washington 98032
Tel: (206) 575-9700
Fax: (206) 575-9800
www.hermanson.com
Contractor Reg #: HERMACLO05BJ
SPLIT
SYSTEMS
COMPASSHEALTH AURORA HOUSE
20903 70TH AVE. W.
EDMONDS, WA 98026
c�ODOR A,
NO ��GISTERV
��SSfUN
May 18, 2021
Revisions
05/14/21 WSS ISSUE FOR PERMIT
No. Date By Description
Design
Design Team
WSS
Drawn FVP
Checked DTN
Pre —Construction Number 14-21-19350
Construction Number
Issue Date 05/14/21
SITE
PLAN
- HVAC
M1.01
ISSUE FOR PERMIT
Mir)RACK11C
I_J 1Y■_JETSIM
�1
Co
o 4'
PARTIAL
^ SCALE: 1/4" = 1'-0"
ti ^
a
OMEN'S
STROOM
MEN'S
QGeTQnnnn
I A Al ITOD
MEN'S
RESTROOM
MED ROOM/
NURSE'S OFFICE
U'DEMO EXIST UNIT
DINING ROOM
ET]
1ST FLOOR DEMO PLAN - HVAC
F,
REPLACE EXIST UNIT W/ NEW UNIT, OF "NAEN'S
THE SAME CAPACITY. RE —CONNECT TO ;OOM
EXIST DUCTWORK & UTILITIES, SEE
EQUIPMENT SCHEDULE FOR DETAILS ON
NEW UNIT (TYP 2)
CU-102
CAH
oN M
5 �
PARTIAL
SCALE: 1/4" = 1'-0"
ti ^
a
SCALE: 4"=1 '
OMEN'S
3TROOM
MEN'S
RGeTL2nnnn
1 A AI ITOD
MEN'S
RESTROOM
REPLACE EXIST UNIT W/ NEW UNIT, OF
THE SAME CAPACITY. RE —CONNECT TO
EXIST DUCTWORK & UTILITIES, SEE
EQUIPMENT SCHEDULE FOR DETAILS ON
NEW UNIT (TYP 2)
MED ROOM/
NURSE'S OFFICE
ViTruCnI
FCU-101
DINING ROOM
1 ST FLOOR PLAN - HVAC
1'
3'
5'
2'
4'
10'
25'
4 G J
�1
o C C ti
[� A
z KEY PLAN
{
SCALE: NONE
�v ^
a
FOR CITY USE:
RECEIVED
May 19 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Hermanson
Building Today, Defining Tomorrow
Hermanson Company LLP
1221 2nd Avenue North
Kent, Washington 98032
Tel: (206) 575-9700
Fax: (206) 575-9800
www.hermanson.com
Contractor Reg #: HERMACLO05BJ
SPLIT
SYSTEMS
COMPASSHEALTH AURORA HOUSE
20903 70TH AVE. W.
EDMONDS, WA 98026
c�ODOR A,
No ��crs�RV
��SSfUN
May 18, 2021
Revisions
05/14/21 WSS ISSUE FOR PERMIT
No. Date By Description
Design Team
Design WSS
Drawn FVP
Checked DTN
Pre —Construction Number 14-21-19350
Construction Number
Issue Date 05/14/21
PARTIAL
1ST FLOOR PLANS
- HVAC
M2001
ISSUE FOR PERMIT