APPROVED BLD PLN BLD2021-0693+Manufacturer_Specifications_and_Installation_Instructions+5.14.2021_11.25.38_AM+2197379r
Complete warranty details available from your local dealer or at
www.daikincomfort.com. Warranty registration not required to
receive the 10-Year parts limited warranty for residential or
commercial installations.
Indoor Specifications
Airflow Rate (cfm)
Cooling
H
M
890
727
L
SL
572
512
Sound (dBA)
H/M/L/SL
53 / 47 / 40 / 37
Dimensions (H x W x D) (in)
13-3/8 x 47-1/4 x 10-3/16
Weight (Lbs)
38
Outdoor Specifications
Compressor
Hermetically Sealed Swing Type
Refrigerant
R-410A
Factory Charge (Lbs)
3.64
Refrigerant Oil
PVE (FVC50K)
Cooling
Airflow Rate (cfm)
H 2,528
Sound Pressure Level(dBA)
56
Dimensions (H x W x D) (in)
28-15/16 x 34-1/4 x 12-5/8
Weight (Lbs)
133
Efficiencv
Cooling
SEER
17.50
EER
9.85
Performance
Cooling (Btu/hr)
Rated (Min/Max)
31,400 (10,200 / 31,400)
Sensible @ AHRI
21,030
Standard Operating Range
SOT — 115 T
Extended Operating Range*
-22°F — 115 T
Rated Cooling Conditions: Indoor: 80°F DB/67°F WB
Outdoor: 95T DB/75"F WB
*With field settings and wind baffle
Electrical
208/60/1
230/60/1
System MCA
17
17
System MFA
20
20
Compressor RLA
16.25
16.25
Outdoor fan motor FLA
.62
.62
Outdoor fan motor W
93
93
Indoor fan motor FLA
.37
.37
Indoor fan motor W
64
64
MFA: Max. fuse amps MCA: Min. circuit amps (A) FLA: Full load amps (A)
RLA: Rated load amps (A) W: Fan motor rated output (W)
Piping
Liquid (in)
1/4
Gas (in)
5/8
Drain (in)
5/8
Max. Interunit Piping Length (ft)
98.4
Max. Interunit Height Difference (ft)
65.625
Chargeless (ft)
32.8
Additional Charge of Refrigerant (oz/ft)
32
Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056
(Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without
notice and without incurring any obligations)
Submittal Revision Date: May 2020 Page 1 of 4
0
�1
I�fi�fil lf�fifi fil lf�fi fif�l
47-1/4 (1200m
42-11/16 (108.'
I
E
v
WALL HOLE FOR EMBEDDED PIPING WALL HOLE
r 03.1/8 (080mm) HOLE 03-1/8 (080mm) HOLE
2-9/16 (65mm) 3-1/2 (89mm)
STANDARD LOCATIONS OF WALL HOLES
v
M
W
U
z
O
u- ¢
ui 0
U LL
�a
(SP'AUL I-UH
(SF'A(;t
FUH
MAINTENANCE)
REQUIRED SPACE
MAINTENANCE)
2-5/16
(58.5mm)
f INCLUDING
MOUNTING PLATE
10-1/4 (261mm)
10-3116 (259mm)
n
c6
non
ii
E NAME ro
o
PLATE
TERMINAL
n
BLOCK
m
WITH GROUND
TERMINAL
WIRELESS
REMOTE
CONTROLLER
(ARC466A37)
0
0
t
.3
iv
v
m
c
0
`o
w
C
C
m
tD
in c c
O O
n f6
X u
H w
u
� v
0 0 --
� � c
c o
O OU 'y,
2 a) 'm
O � bo
Ln u O
W
7 O m
N Q bb
C
Q- w
iy O u
C E •r-
m 0 'o
~�
Ln c: •-
Ln 3
v
J � C
J m
V � V
v v o
E C
s c
Y
Z Q
Y C
m �
Q E
0
n
E
0
0 0
u
O
u
a
m
u
a
n
Y_
m
Q
a
0
N
m
a
0
4-HOLES FOR FOUNDATION BOLTS
2-GROUND TERMINALS
6-13/16
IN CASE OF REMOVING
STOP VALVE COVER AND
TERMINAL STRIP COVER
DRAIN OUTLET
(I.D $5/8 (015.9) HOSE FOR
ELECTRIC WIRE INTAKE
OUTDOOR AIR THERMISTOR
d
0
MWIMUM SPACE FOR AIR PASSAGE WALL. HEIGHT ON AIR OUTLET SIDE
=LESS THAN 47-1/4 (1200)
1-15/16 (50)
(7
Q
O
(`
1-15116 (50) 1
-15/16
(50)
Ch
�r
C?
Q r
UNIT: inch (mm)
a
3
O O
� m
•3 a,
oa
v a
c
0
p
`o
w
C
r
C
m
Ln r-
N
O 0
n -
n co
x �
H w
- u
C ai
O O- ^
N
Yn v^ C
0 C O
O on
O N
O
to u O
aJ 7
0 m
vi n un
Q-
C w •i
iy 0 u
C E •�
H O O
~ t 0
'-I Oil •—
Ln 3
ai
J � C
J m
m � V
V i
a) N O
E C
a
Y
O m
z o
C
Y C
m ai
E
CL
E
O
m
C
O O
u N
O O
N
u >�
ai m
v �
m
c
u O
O N
n K
v1 fa
•C
Y E
m .0
v N
Optional Accessories r"DA/K1
Indoor Unit
Included
Part Number
Description
BRP072A43
Wireless Interface Adapter
BRC944B2-A08
Wired Remote Controller kit
BRCW90IA08
Wired Remote Controller Cable — 25ft included in above kit
BRCW901A03
Wired Remote Controller Cable —10 ft
DACA-CPI-I
Inline Condensate Pump (Fits inside all Daikin wall & floor mount units
DACA-CP4-1
External Condensate Pump
KRP928BB2S
Interface Adaptor for DIII-NET
Outdoor Unit
Included Part Number Descri tion
KPW063B4 Air Ad'ustment Grille RX & RK
KKG063A42 Back rotection wire net
Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056
(Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without
notice and without incurring any obligations)
Submittal Revision Date: May 2020 Page 4 of 4
. KIN
Submittal Data Sheet
3.0 Ton VRV-IVS Heat Pump
RXTQ36TAVJ9A
FEATURES
0 Variable Refrigerant Temperature (VRT) technology allows VRV IV S series to deliver improved efficiencies and
year round comfort
0 Improved efficiencies with SEER values up to 18.0 and HSPF values up to 10.0
0 Engineered with highly reliable Daikin Swing compressors
0 All inverter compressors to increase efficiency and avoid starting current rush
0 Can provide heating down to -4°F
_
-
0 Added safety with optional auto changeover to auxiliary heat
0 Easier installation with over 60%weight reduction compared to VRV III S
-
BENEFITS
0 Single-phase technology enables installation in light commercial and residential applications
1
0 Broader diversity with up to 9 indoor units connectivity
V14
0 Space saving compact design
0 Design flexibility with long piping lengths up to 984ft total and 49ft vertical separation between indoor units
0 Designed with reduced MOP to optimize installation costs
0 Backed by best in class 10-years Parts Limited Warranty and 10-years Replacement Compressor Limited
Warranty
I r Ir
"IERPq
1
C(
�S
IV
<ISTEO
Daikin North America LLC, 19001 Kamtier Rd, Waller, TX 77484
Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com
(Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations)
Submittal Date: 9/9/2020 6:13:22 PM Page 1 of 3
. KIN
Submittal Data Sheet
3.0 Ton VRV-IVS Heat Pump
RXTQ36TAVJ9A
PERFORMANCE
Outdoor Unit Model No.
RXTQ36TAVJ9A
Outdoor Unit Name:
3.0 Ton VRV-IVS Heat Pump
Type:
Heat Pump
Rated Cooling Conditions:
Indoor (°F DB/DB): 80 / 67
Ambient (°F DBNUB): 95 / 75
Rated Heating Conditions:
Indoor (°F DB/VY81: 70 160
Ambient (°F DB B): 47 / 43
Rated Piping Length(ft):
25
Rated Height Difference (fl):
Rated Cooling Capacity (Btu/hr):
34,200
Rated Heating Capacity (Btu/hr):
37,000
Cooling Input Power (kW):
3.13
Heating Input Power (kW):
3.12
EER (Non-Ducted/Ducted):
12.00 / 10.00
Heating COP (Non-Ducted/Ducted):
/
SEER (Non-Ducted/Ducted):
18.00 / 16.00
HSPF (Non-Ducted/Ducted):
10.3 / 9.0
Max(Min Cooling Capacity (Btu/hr):
/
Max/Min Heating Capacity (Btu/hr):
OUTDOOR UNIT DETAILS
Power Supply (V/Hz/Ph):
208-230 / 60 / 1
Compressor Stage:
Inverter
Power Supply Connections:
Capacity Control Range (%):
14 - 100
Min. CircuitAmps MCA (A):
16.5
Airflow Rate (H) (CFM):
2682
Max Overcurrent Protection (MOP) (A):
Max Starting Current MSC(A):
25
Gas Pipe Connection (inch):
Liquid Pipe Connection (inch):
5/6
318
Rated Load Amps RLA(A):
Dimensions (HxWxD) (in):
Net Weight (Ib):
15.3
39 x 37 x 12-5/8
172
Sound Pressure (H) (dBA):
Sound Power Level (dBA):
58
75
Daikin North America LLC, 19001 Kamiier Rd, Waller, TX 77484
Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com
(Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations)
Submittal Date: 9/9/2020 6:13:22 PM Page 2 of 3
. KIN
Submittal Data Sheet
3.0 Ton VRV-IVS Heat Pump
RXTQ36TAVJ9A
SYSTEM DETAILS
Refrigerant Type: R-410A Cooling Operation Range (°F DB): 23 - 122
Holding Refrigerant Charge (lbs): 6.4 Healing Operation Range (°F WB): A - 60
Additional Charge (lb/ft): Max. Pipe Length (Vertical) (ft): 98
Pre -charge Piping (Length)(ft): Cooling Range w/Baffle ff DB): -
Max. Pipe Length (Total) (ft): 820 Heating Range w/Baffle (°F WB): -
Max Height Separation (Ind to Ind ft):
DIMENSIONAL DRAWING
Unit: in.
U
0
0
0
0
0
0
0
0
.0
Daikin North America LLC, 19001 Kamtier Rd, Waller, TX 77484
Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com
(Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations)
Submittal Date: 9/9/2020 6:13:22 PM Page 3 of 3
A f KI
Submittal Data Sheet
3.0-Ton Ceiling Suspended Unit
FXHQ36MVJU
FEATURES
RECEIVED
May 19 2021
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
■ One of our slimmest indoor units (less than ME) fits any interior design
■ Wide air discharge outlet distributes a comfortable airflow throughout the
entire space
f Silent stream fan technology keeps sound pressure levels low
■ Unit requires minimal installation space
■ Standard Limited Warranty: 10-year warranty on compressor and all parts
�NTERTFk
US
VARY
VC
HOSTED
Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056
Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com
(Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without
incurring any obligations)
Submittal Date: 3/5/2020 2:01:13 PM Page 1 of 3
. KIN
Submittal Data Sheet
3.0-Ton Ceiling Suspended Unit
FXHQ36MVJU
PERFORMANCE
Indoor Unit Model No. FXHQ36MVJU
Type: Ceiling Suspended
Rated Cooling Capacity (Btu/hr): 36,000
Sensible Capacity (Btu/hr): 25,100
Cooling Input Power (kW): 0.160
Rated Heating Capacity (Btu/hr): 40,000
Heating Input Power (kW): 0.16
Power Supply (V/Hz/Ph):
208-230 / 60 / 1
Power Supply Connections: L1, L2, Ground
Min. Circuit Amps MCA (A): 1.4
Max Overcurrent Protection (MOP) (A): 15
Dimensions (HxWxD) (in): 7-11/16 x 62-5/8 x 26-3/4
Net Weight (lb): 90
Ext. Static Pressure (Rated/Max) (inWg): /
Indoor Unit Name:
Rated Cooling Conditions:
Rated Heating Conditions:
Rated Piping Length(ft):
Rated Height Separation (ft):
3.0-Ton Ceiling Suspended Unit
Indoor (°F DB/WB): 80 / 67
Ambient ff DB/WB): 95 / 75
Indoor (°F DB/WB): 70 / 60
Ambient ff DB/WB): 47 / 43
Airflow Rate (H/L) (CFM): 830/670
Moisture Removal (Gal/hr):
Gas Pipe Connection (inch): 5/8
Liquid Pipe Connection (inch): 3/8
Condensate Connection (inch): 1
Sound Pressure (H) (dBA): 46
Sound Power Level (dBA):
Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056
Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com
(Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without
incurring any obligations)
Submittal Date: 3/5/2020 2:01:13 PM Page 2 of 3
. KIN
Submittal Data Sheet
3.0-Ton Ceiling Suspended Unit
FXHQ36MVJU
DIMENSIONAL DRAWING
FXHQ36MVJU
Unit (in.)
for backward pipe connection
from the front)
26-1/3
Position of holes in the wall
for backward pipe connection
(view from the front)
Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056
Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com
(Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without
incurring any obligations)
Submittal Date: 3/5/2020 2:01:13 PM Page 3 of 3