APPROVED BLD PLN BLD2021-0693+Manufacturer_Specifications_and_Installation_Instructions+5.14.2021_11.25.38_AM+2197379r Complete warranty details available from your local dealer or at www.daikincomfort.com. Warranty registration not required to receive the 10-Year parts limited warranty for residential or commercial installations. Indoor Specifications Airflow Rate (cfm) Cooling H M 890 727 L SL 572 512 Sound (dBA) H/M/L/SL 53 / 47 / 40 / 37 Dimensions (H x W x D) (in) 13-3/8 x 47-1/4 x 10-3/16 Weight (Lbs) 38 Outdoor Specifications Compressor Hermetically Sealed Swing Type Refrigerant R-410A Factory Charge (Lbs) 3.64 Refrigerant Oil PVE (FVC50K) Cooling Airflow Rate (cfm) H 2,528 Sound Pressure Level(dBA) 56 Dimensions (H x W x D) (in) 28-15/16 x 34-1/4 x 12-5/8 Weight (Lbs) 133 Efficiencv Cooling SEER 17.50 EER 9.85 Performance Cooling (Btu/hr) Rated (Min/Max) 31,400 (10,200 / 31,400) Sensible @ AHRI 21,030 Standard Operating Range SOT — 115 T Extended Operating Range* -22°F — 115 T Rated Cooling Conditions: Indoor: 80°F DB/67°F WB Outdoor: 95T DB/75"F WB *With field settings and wind baffle Electrical 208/60/1 230/60/1 System MCA 17 17 System MFA 20 20 Compressor RLA 16.25 16.25 Outdoor fan motor FLA .62 .62 Outdoor fan motor W 93 93 Indoor fan motor FLA .37 .37 Indoor fan motor W 64 64 MFA: Max. fuse amps MCA: Min. circuit amps (A) FLA: Full load amps (A) RLA: Rated load amps (A) W: Fan motor rated output (W) Piping Liquid (in) 1/4 Gas (in) 5/8 Drain (in) 5/8 Max. Interunit Piping Length (ft) 98.4 Max. Interunit Height Difference (ft) 65.625 Chargeless (ft) 32.8 Additional Charge of Refrigerant (oz/ft) 32 Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date: May 2020 Page 1 of 4 0 �1 I�fi�fil lf�fifi fil lf�fi fif�l 47-1/4 (1200m 42-11/16 (108.' I E v WALL HOLE FOR EMBEDDED PIPING WALL HOLE r 03.1/8 (080mm) HOLE 03-1/8 (080mm) HOLE 2-9/16 (65mm) 3-1/2 (89mm) STANDARD LOCATIONS OF WALL HOLES v M W U z O u- ¢ ui 0 U LL �a (SP'AUL I-UH (SF'A(;t FUH MAINTENANCE) REQUIRED SPACE MAINTENANCE) 2-5/16 (58.5mm) f INCLUDING MOUNTING PLATE 10-1/4 (261mm) 10-3116 (259mm) n c6 non ii E NAME ro o PLATE TERMINAL n BLOCK m WITH GROUND TERMINAL WIRELESS REMOTE CONTROLLER (ARC466A37) 0 0 t .3 iv v m c 0 `o w C C m tD in c c O O n f6 X u H w u � v 0 0 -- � � c c o O OU 'y, 2 a) 'm O � bo Ln u O W 7 O m N Q bb C Q- w iy O u C E •r- m 0 'o ~� Ln c: •- Ln 3 v J � C J m V � V v v o E C s c Y Z Q Y C m � Q E 0 n E 0 0 0 u O u a m u a n Y_ m Q a 0 N m a 0 4-HOLES FOR FOUNDATION BOLTS 2-GROUND TERMINALS 6-13/16 IN CASE OF REMOVING STOP VALVE COVER AND TERMINAL STRIP COVER DRAIN OUTLET (I.D $5/8 (015.9) HOSE FOR ELECTRIC WIRE INTAKE OUTDOOR AIR THERMISTOR d 0 MWIMUM SPACE FOR AIR PASSAGE WALL. HEIGHT ON AIR OUTLET SIDE =LESS THAN 47-1/4 (1200) 1-15/16 (50) (7 Q O (` 1-15116 (50) 1 -15/16 (50) Ch �r C? Q r UNIT: inch (mm) a 3 O O � m •3 a, oa v a c 0 p `o w C r C m Ln r- N O 0 n - n co x � H w - u C ai O O- ^ N Yn v^ C 0 C O O on O N O to u O aJ 7 0 m vi n un Q- C w •i iy 0 u C E •� H O O ~ t 0 '-I Oil •— Ln 3 ai J � C J m m � V V i a) N O E C a Y O m z o C Y C m ai E CL E O m C O O u N O O N u >� ai m v � m c u O O N n K v1 fa •C Y E m .0 v N Optional Accessories r"DA/K1 Indoor Unit Included Part Number Description BRP072A43 Wireless Interface Adapter BRC944B2-A08 Wired Remote Controller kit BRCW90IA08 Wired Remote Controller Cable — 25ft included in above kit BRCW901A03 Wired Remote Controller Cable —10 ft DACA-CPI-I Inline Condensate Pump (Fits inside all Daikin wall & floor mount units DACA-CP4-1 External Condensate Pump KRP928BB2S Interface Adaptor for DIII-NET Outdoor Unit Included Part Number Descri tion KPW063B4 Air Ad'ustment Grille RX & RK KKG063A42 Back rotection wire net Daikin North America LLC 5151 San Felipe, Suite 500 Houston, TX 77056 (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date: May 2020 Page 4 of 4 . KIN Submittal Data Sheet 3.0 Ton VRV-IVS Heat Pump RXTQ36TAVJ9A FEATURES 0 Variable Refrigerant Temperature (VRT) technology allows VRV IV S series to deliver improved efficiencies and year round comfort 0 Improved efficiencies with SEER values up to 18.0 and HSPF values up to 10.0 0 Engineered with highly reliable Daikin Swing compressors 0 All inverter compressors to increase efficiency and avoid starting current rush 0 Can provide heating down to -4°F _ - 0 Added safety with optional auto changeover to auxiliary heat 0 Easier installation with over 60%weight reduction compared to VRV III S - BENEFITS 0 Single-phase technology enables installation in light commercial and residential applications 1 0 Broader diversity with up to 9 indoor units connectivity V14 0 Space saving compact design 0 Design flexibility with long piping lengths up to 984ft total and 49ft vertical separation between indoor units 0 Designed with reduced MOP to optimize installation costs 0 Backed by best in class 10-years Parts Limited Warranty and 10-years Replacement Compressor Limited Warranty I r Ir "IERPq 1 C( �S IV <ISTEO Daikin North America LLC, 19001 Kamtier Rd, Waller, TX 77484 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date: 9/9/2020 6:13:22 PM Page 1 of 3 . KIN Submittal Data Sheet 3.0 Ton VRV-IVS Heat Pump RXTQ36TAVJ9A PERFORMANCE Outdoor Unit Model No. RXTQ36TAVJ9A Outdoor Unit Name: 3.0 Ton VRV-IVS Heat Pump Type: Heat Pump Rated Cooling Conditions: Indoor (°F DB/DB): 80 / 67 Ambient (°F DBNUB): 95 / 75 Rated Heating Conditions: Indoor (°F DB/VY81: 70 160 Ambient (°F DB B): 47 / 43 Rated Piping Length(ft): 25 Rated Height Difference (fl): Rated Cooling Capacity (Btu/hr): 34,200 Rated Heating Capacity (Btu/hr): 37,000 Cooling Input Power (kW): 3.13 Heating Input Power (kW): 3.12 EER (Non-Ducted/Ducted): 12.00 / 10.00 Heating COP (Non-Ducted/Ducted): / SEER (Non-Ducted/Ducted): 18.00 / 16.00 HSPF (Non-Ducted/Ducted): 10.3 / 9.0 Max(Min Cooling Capacity (Btu/hr): / Max/Min Heating Capacity (Btu/hr): OUTDOOR UNIT DETAILS Power Supply (V/Hz/Ph): 208-230 / 60 / 1 Compressor Stage: Inverter Power Supply Connections: Capacity Control Range (%): 14 - 100 Min. CircuitAmps MCA (A): 16.5 Airflow Rate (H) (CFM): 2682 Max Overcurrent Protection (MOP) (A): Max Starting Current MSC(A): 25 Gas Pipe Connection (inch): Liquid Pipe Connection (inch): 5/6 318 Rated Load Amps RLA(A): Dimensions (HxWxD) (in): Net Weight (Ib): 15.3 39 x 37 x 12-5/8 172 Sound Pressure (H) (dBA): Sound Power Level (dBA): 58 75 Daikin North America LLC, 19001 Kamiier Rd, Waller, TX 77484 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date: 9/9/2020 6:13:22 PM Page 2 of 3 . KIN Submittal Data Sheet 3.0 Ton VRV-IVS Heat Pump RXTQ36TAVJ9A SYSTEM DETAILS Refrigerant Type: R-410A Cooling Operation Range (°F DB): 23 - 122 Holding Refrigerant Charge (lbs): 6.4 Healing Operation Range (°F WB): A - 60 Additional Charge (lb/ft): Max. Pipe Length (Vertical) (ft): 98 Pre -charge Piping (Length)(ft): Cooling Range w/Baffle ff DB): - Max. Pipe Length (Total) (ft): 820 Heating Range w/Baffle (°F WB): - Max Height Separation (Ind to Ind ft): DIMENSIONAL DRAWING Unit: in. U 0 0 0 0 0 0 0 0 .0 Daikin North America LLC, 19001 Kamtier Rd, Waller, TX 77484 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date: 9/9/2020 6:13:22 PM Page 3 of 3 A f KI Submittal Data Sheet 3.0-Ton Ceiling Suspended Unit FXHQ36MVJU FEATURES RECEIVED May 19 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ■ One of our slimmest indoor units (less than ME) fits any interior design ■ Wide air discharge outlet distributes a comfortable airflow throughout the entire space f Silent stream fan technology keeps sound pressure levels low ■ Unit requires minimal installation space ■ Standard Limited Warranty: 10-year warranty on compressor and all parts �NTERTFk US VARY VC HOSTED Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date: 3/5/2020 2:01:13 PM Page 1 of 3 . KIN Submittal Data Sheet 3.0-Ton Ceiling Suspended Unit FXHQ36MVJU PERFORMANCE Indoor Unit Model No. FXHQ36MVJU Type: Ceiling Suspended Rated Cooling Capacity (Btu/hr): 36,000 Sensible Capacity (Btu/hr): 25,100 Cooling Input Power (kW): 0.160 Rated Heating Capacity (Btu/hr): 40,000 Heating Input Power (kW): 0.16 Power Supply (V/Hz/Ph): 208-230 / 60 / 1 Power Supply Connections: L1, L2, Ground Min. Circuit Amps MCA (A): 1.4 Max Overcurrent Protection (MOP) (A): 15 Dimensions (HxWxD) (in): 7-11/16 x 62-5/8 x 26-3/4 Net Weight (lb): 90 Ext. Static Pressure (Rated/Max) (inWg): / Indoor Unit Name: Rated Cooling Conditions: Rated Heating Conditions: Rated Piping Length(ft): Rated Height Separation (ft): 3.0-Ton Ceiling Suspended Unit Indoor (°F DB/WB): 80 / 67 Ambient ff DB/WB): 95 / 75 Indoor (°F DB/WB): 70 / 60 Ambient ff DB/WB): 47 / 43 Airflow Rate (H/L) (CFM): 830/670 Moisture Removal (Gal/hr): Gas Pipe Connection (inch): 5/8 Liquid Pipe Connection (inch): 3/8 Condensate Connection (inch): 1 Sound Pressure (H) (dBA): 46 Sound Power Level (dBA): Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date: 3/5/2020 2:01:13 PM Page 2 of 3 . KIN Submittal Data Sheet 3.0-Ton Ceiling Suspended Unit FXHQ36MVJU DIMENSIONAL DRAWING FXHQ36MVJU Unit (in.) for backward pipe connection from the front) 26-1/3 Position of holes in the wall for backward pipe connection (view from the front) Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056 Daikin City Generated Submittal Data www.daikinac.com www.daikincomfort.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date: 3/5/2020 2:01:13 PM Page 3 of 3