BLD2021-1029_Other_7.26.2021_8.27.55_AM_2320352SOLAR PV SYSTEM DETAILS TOTAL MODULE(S) 14 TOTAL DC POWER 4.62kW OPERATING VOLTAGE 240V MAX AC POWER OUT 7.8KVA MODULE 1 DATA MODULE MODEL SILFAB SIL-330 HL vmpp 33.70V IMPP 9.80A Voc 40.1 OV I 10.40A V TEMP COEFF -0.28%/"C MIN DESIGN TEMP 10°C MODULE 2 DATA MODULE MODEL ITEK IT-275-HE Vmpp 32.1 V IMPP 8.5A Voc 39.OV I 9.2A Vt. TEMP COEFF -0.32%/"C MIN DESIGN TEMP -40'C BUSBAR CALCULATIONS MAIN I PV IBUSBARI TOTAL SUPPLY% 200 1 40A 1 200 1 120 %5120 % CONDUIT CURRENT CALCULATIONS #12 THWN-2 ALLOWABLE CURRENT 30A CURRENT CARRYING CONDUCTORS 2 ADJUSTMENT FACTOR 80% ADJUSTED ALLOWED CURRENT 24A STRING MAX AC OUTPUT CURRENT 14A OVERCURRENT PROTECTION NEC 2020]05.12B 8210.20A MAX AC OUTPUT 25 % 1SAFETY OCPD SIZE " PV STRING MAX N/A 20A " PV TOTAL 32A 40A FEEDER SCHEDULE O POWER OPTIMIZER CONNECTORS + #6 BARE EGC IN OPEN AIR (2) #12 THWN-2 +(1) #12 GND IN 3/4" EMT ® NOT USED (2) #12 THWN-2 + (1) #12 THWN-2 NEUT + (1) #12 GND IN 3/4" EMT ® NOT USED ® (2) #10 THWN-2 + (1) #10 THWN-2 NEUT + (1) #10 GND IN 1" EMT (�) (2) #10 THWN-2 + (1) #10 THWN-2 NEUT + (1) #10 GND IN 1" PVC 1®l NOT USED FLAG NOTES: BACKFEEDING INTO MAIN PANEL IN COMPLIANCE WITH NEC 2020 705.12(B)(3)(2) - SUM OF PV AND MAIN 120% OF BUSBAR MONITORING DEVICE CT LEADS, (2) 18 AWG IN 1/2" EMT INVERTER 1 DATA INVERTER 2 DATA INVERTER MODEL SOLAREDGE SE380OH-US INVERTER MODEL DELTA M4-TL-US MAX DC IN 380V MAX DC IN 380V MAX CURRENT IN 10.5A MAX CURRENT IN 12A MAX AC OUT 3.8KVA MAX AC OUT 4.OKVA MAX CURRENT OUT 16A I MAX CURRENT OUT 16A EXISTING INVERTER 2 DELTA M4 PV DC DISCONNECT # MODULES: 13 IMP = 8.5A Vmp = 417V Voc = 507V a a °C Isc = 9.2A \ J b 125A SUBPANEL MONITORING + + EXISTING STRING OF + + DEVICE 125A MAIN LUG SUBPANEL 125A BUS BAR 13 MODULE 2 2OA 40A 20A� NEW INVERTER 1 o- SE380OH-US P370 DC OPTIMIZER 0 PV DC DISCONNECT ° # MODULES: 14 b IMP = 12.2A VMp = 380V DELDc- ° Voc = 480V 3 O Isc = 15A MONITORING + + NEW + + O DEVICE o% STRING OF 60A UNFUSED 14 MODULE 1 AC DISCONNECT ROOF EXTERIOR INTERIOR EXTERIOR LEGEND 0 4 PUGET SOUND SOLA 805 Rainier Ave S Seattle, WA 98144 Tel: 206-706-1931 W X mod, ioa oak �o z� -oo co¢ N o. GROUNDING O a 52 o K SO M UL ❑J JUNCTION BOX O ODUCTION METER OM N T METER ®SED AC DISCONNECT FUSED AC DISCONNECT I ICROINVERTER + DC OPTIMIZER UTILITY SERVICE Q Z 00 aD M Y w D_ L�2 E D_ E J UU ?-Z 0 ova yza 3� wC1w oro boy oaw yw ioa Duo 3w15 �1w ow F U �00 LOAD CENTER 0 PREUMINARY DESIGN 72121 REV DESCRIPTION DATE DRAWN BY AB 200A MAIN 200A BUS CHECKED BY AL PROJECT #: 14111 SALES: JEFF PERAMBO PM: BILL ULSUND _ PM CELL: (253) 951-0385 ELECTRICAL ONE LINE 40A DIAGRAM PV-102 EXISTING