APPROVED BLD2020-0349 BLD PLN Arch Struct permit set 6.11.20VICINITY MAP:
PROJECT SITE:
1141 VIEWLAND WAY
W(K0WAY
PUGFTLA
v
EDMONDS
MiUN Ti
� w
176rH ST SW
1 &TH ST SW
LU
LU
1 BOTH ST 3W
W
=
LYNN1 OOD
I�
1 96TH STSVV
200rH Srs
�v z
{
24 4TH Sr 5W
'
)OSTH Sr SW c 41
2? 2TH Sr SW r
4 UNINCORPORATED
COUNTY
220THSr34
_
ESPERANCE
is 228THST 90i
a
MOUNTLAKE
TERRACE
3.
w
Lr
_
` ^ 236TH ST SW
z
EXTERIOR MODELING SKETCHES (FOR REFERENCE ONLY)
SCHEMATIC VIEW FROM SE
SCHEMATIC VIEW FROM SW
PROJECT INFORMATION:
PROJECT SITE ADDRESS:
1141 VIEWLAND WAY
EDMONDS, WASHINGTON 98020
PROPERTY OWNER
TERRI MAUPIN & PETE CROUCH
6046 ANN ARBOR AVE. NE
SEATTLE, WA 98115
terrim99@gmail.com
ARCHITECT:
AIELLO ARCHITECTURE
928 NW LEARY WAY, #201
SEATTLE, WASHINGTON 98107
Contact: Paul Aiello
paul@aielloarchitecture.com
206.632.1229
STRUCTURAL ENGINEER
D.S. ENGINEERING
3121 147TH PLACE SE
MILL CREEK, WA 09012
Contact: Don Shin
425.338.4776
GEOTECHNICAL ENGINEER
ASSOCIATED EARTH SCIENCES, INC.
911 5TH AVENUE
KIRKLAND, WA 98033
Contact: Tony Romanick
425.827.7701
CIVIL ENGINEER
CG ENGINEERING
250 4TH AVE. S.
EDMONDS, WA 98020
Contact: Greg Gullien
425.778.8500
ZONING:
RS-12
TAX PARCEL NO.
SNOH. CO. Assessors # 00606600001800
LEGAL DESCRIPTION:
VIEWLAND HEIGHTS, BLK 000 D-00 - LOT 18
PROJECT DESCRIPTION:
CONSTRUCT ANEW SINGLE FAMILY
RESIDENCE IN SIMILAR LOCATION AS
EXISTING
DEMOLISH EXISTING RESIDENCE.
UTILIZE EXISTING DRIVEWAY AND
LANDSCAPE TO EXTENT FEASIBLE
1 ST FLOOR
2044 sq
ft
2ND FLOOR
700 sq
ft
GARAGE
710 sq
ft
TOTAL BUILDING PROPOSED
3454 sq
ft
GENERAL BUILDING NOTES:
CONSTRUCTION TYPE:
VB
OCCUPANCY:
R3 SINGLE FAMILY RESIDENCE
U GARAGE
FIRE SPRINKLER:
PER ECDC 19.05.020, R313.1.2
FOR TOTAL AREA RESIDENCE OVER 3000 SF,
PROVIDE SPRINKLER SYSTEM PER NFPA 13D.
BUILDING CODE:
: 2015 IRC, ARCHITECTURAL
2015 IBC, STRUCTURAL
SEE S1.0 FOR CODE NOTES
SHEET INDEX:
AO.0 PROJECT INFORMATION
VICINITY MAP
MODEL VIEWS
A1.0 SITE PLAN
A1.1 TYPICAL ENVELOPE ASSEMBLIES
WINDOW & EXT. DOOR SCHEDULE
INTERIOR DOOR & HW SCHEDULE
ENERGY CODE NOTES
CLIMATE & GEOGRAPHIC DESIGN CRITERIA
C1.1 CIVIL COVER SHEET & GENERAL NOTES
C2.1 TEMPORARY EROSION CONTROL & DEMO
C2.2 TEMPORARY EROSION CONTROL DETAILS
C3.1 GRADING & DRAINAGE PLAN & DETAILS
C3.2 GRADING & DRAINAGE DETAILS
C4.1 WATER & SEWER PLAN
C4.2
WATER & SEWER DETAILS
A2.1
1ST FLOOR PLAN
A2.2
2ND FLOOR PLAN
A2.3 ROOF PLAN
A3.1 EXTERIOR ELEVATIONS
A3.2 EXTERIOR ELEVATIONS
A4.1 BUILDING SECTIONS
ENERGY CODE NOTES
A4.2 BUILDING SECTIONS
A5.1 WALL SECTIONS & DETAILS
A5.2 WALL SECTIONS & DETAILS
S1.0 STRUCTURAL NOTES
TYPICAL STRUCTURAL DETAILS
S2.0 FOUNDATION PLAN
PIN PILE PLAN
S2.1 1ST FLOOR FRAMING PLAN
S2.2 2ND FLOOR & LOW ROOF FRAMING PLAN
1 ST TO 2ND SHEAR WALLS
S2.3 UPPER ROOF FRAMING PLAN
2ND TO UPPER ROOF SHEAR WALLS
S3.0 STRUCTURAL DETAILS TYPICAL
S3.1 STRUCTURAL DETAILS & SECTIONS
a u I aieIIo, p.s.
j architecture + design
7818
V
EGISTERED
ARCHITECT
t
IELLOASHINGTON
w
U
z
w
0
Vl
w
a
z
0. o
O
Q CD
Z � N
E
U�w
03.24.2020
0:
-
0
--
INDEX OF DRAWINGS
PROJECT INFO
WINDOW SCHEDULE
DOOR SCHEDULE
SITE GENERAL NOTES
A. EXISTING SITE SURVEY SHOWN AS BACKGROUND. SEE ACTUAL
SURVEY FOR MORE EXTENSIVE DETAIL.
B. SEE CIVIL DRAWINGS FOR TEMPORARY EROSION CONTROLS,
SITEWORK DETAILS, AND UTILITIES.
C. SEE GEOTECH REPORT FOR E.C.A. INFORMATION AND
RECOMMENDATIONS.
HEIGHT CALCULATIONS
Proposed Comer points Elevation
A
237.80'
B
237.60'
C
237.40'
D
237.80'
Subtotal
950.60'
AVERAGE SITE ELEVATION
237.65'
MAX. ALLOWABLE HEIGHT.:
25.00'
MAX. ALLOWABLE ELEVATION
262.65'
MAX. PROPOSED ELEVATION
258.50'
(NOTE. SURVEY DATUM USED)
PROPERTY INFORMATION
kq
OWNER
TERRI MAUPIN & PETE CROUCH
PROPERTY ADDRESS:
1141 VIEWLAND WAY
EDMONDS, WASHINGTON 98020
TAX PARCEL NO.
606600001800
°
RECOMMENDED BUILDING SET BACK BUFFER —
OF 10' MINIMUM FROM TOP OF WEST SLOPE,
PER GEOTECH REPORT DTD 1-10-2020 PAGE 8.
/ i b
PROPOSED: 20' '
+/- / p I I /
^ tiI 1: 1 I I I
REFERENCE O / 0 1 I I
PL CORNER POINT z I I
° " 1 i —
w II 25'-564 2
,� 20' +/- x . 7'-8" 15'-01, 15'-0" 26'-6"
VO m l I 1 _0. 7.a x I I' I LT
/.
EQD PEraACK
20" P11
13 IN883618W 115.00' ��I,A/CK221.0 SEI
t
REMOVE 10'FIR
I E W�
LA N D WAY
EXT G TOP OF WEST ao 1I
REUgVE 12'FIR 101SLOPE 237.8 ooF EAVE, 12" FIR
(NO WORK) 237.—8: 23716'
w
x
D.S.
1
I I II I I 2ND FLOO
I 1
/ABOVE IGHEST POINT
NEW WEST SIDE 1 I I v
PATIO PAVING I I I SHOWN DASHED EAVE ELEV.: 258.5 , /11 1
Al GRADE LEVEL ' I 2ND FIN. FLR. �I I 2�..,
2�s.o i l ' k2 I ELEV.: 248.2' aP 1
I I I 1 N
583 SF TO THE SKY _ 23� 11
7,-6w+/ II II � 1 1 1�^N ryh0 x 0h
SEE CIVIL DRAWINGS
I I I GARAG E x I I I 1 I
I p. OLD RESIDENCE
I I N LOT COVERAGE: 710 SIF 0
1 ' TO BE DEMOLISHED OI I I I
I `�' I I I FOOTPRINT SHOWN LAB ELEV-238.6'/1 O1 EAST SLOPE I I
ALIGN I WEST SLOPE', I DOTTED/ ' DOOR -n NO WORK I
NEW CONSTRUCTION NO WORK I - - - _ oCA
f
WITH WEST PL I x23'� - w " ryNCI m I � S�4 II I
l i I I N 1100F EAVE ����G A X LOC
O
I I --_I \
I
I � /RESIDENCE � I G p. , I � I SIDE SEWER,
- ADJACENT �� � ; I I I I� I
LOT COVERAGE: 2044 SF��. I I CITY RECODS
RESIDENCE ; I I Ic I I D.S. D. : I V, e�P�� i
IW C I N I o II
I �,��� , w I �
I 1ST FIN. FLR. ,�. OVEREDIPORCH
ILL ELEV.: TIN. FILR LOT COVEIRAGE: 35 SF o I
ILL I I- I N
10
R4 I I I w
�N x
W I� �W I -
lo I I - I
K*1 I~ I I �o ' 100 I �Ib I u �
0� I i i z I Io x�1b S. 6 I DRIVEWAY 9 EAST SIDE I A _
V
I co
o PAVING REPLACED q 00 I 249.9s
M
I I I ` ` 680 SF TO T�E SKY I N
s I I D.S. �- SEE CIVIL I - co
I I I I ROOF AREA I� a j I+ I o 0
WEST SLOPE ' r 3574 SF i \ I I pI I
NO WORK I SHOWN HATCHED
DRAIN LOCA�fION I
COVERED PATIO I APPROX.
LOT COVERAGE: 115 SF II , ', I SEE CIVIL
x -- - ---- -_--- I I I12"FIR II
1 - - - - - - - - - - - - - - -
I �
' D: 237.8' OP-------�--- --: ", C 2374 0
�?
EXISTING WEST SLOPE I I I
TO REMAIN I .�„ 23,7,\'
NO WORK THIS AREA y� I ,Y I j �, 0 �\ k��\ 1 g P�' FIRR�I
SEE GEOTECH. REPORT G�Q�G
m EXISTING
,N /N 0'\ �,� PAVING TO REMAIN �,�
12" Pi, ti �' 'Sao
SEE CIVIL
T ) 10r CED
,,.° / oa '�4 6
42 / 4
10" PIN N 2x2
's P WM� —/ 1 24
y
i.4-22\ N
6 ' i7227,8s \ 2assa / 10" FIR
225.3 x a .� x TOP OF L g
.y, / w
�x-241.73
a x
O
238.0
p3 r AILBOX s " I
APiROX LOC OF GAS
PER CITY RECORDS
I
�z
3) MAILBOXES
D IRON
PINE
i /
x
7 S
OF
x°0
231.73 x \ 233.94 x C x "`.� ,t'L
�'L
b^ r
PROP COR
N88°36'1$'W 589.36'
\
ry° o
SSMH
1
%RTH
Sfi
SW
VIEW
AKI
ti°�
RIM=245.04'
E 8"CONC(N 1W
D WAY) \
m �
CB (TYPE 1)
RIM=239.23'
IE 6"DI=238.2T(E.j
IE 6"DI=238.13'(W.)
N ry
h
rye.
8"CONC=241 .50'
=239.64'(C.C.)
35
STRUCTURAL LOT COVERAGE
ALLOWABLE LOT COVERAGE
LOT AREA
11499 sq ft
ALLOWANCE
35%
TOTAL ALLOWABLE
4024.65 sq ft
PROPOSED LOT COVERAGE
RESIDENCE
2044 sq ft
GARAGE
710 sq ft
COVERED PORCH
35 sq ft
COVERED PATIO
115 sq ft
TOTAL PROPOSED
2904 sq ft
EXISTING EAST SLOPE, TO REMAIN,
NO BUFFER REQUIRED.
PROVIDING 7'6" BUFFER +/-
SEE GEOTECH REPORT
DATED 1-10-2020, PAGE 8.
EXSTING TOE OF SLOPE
(NO WORK)
ADJACENT -
RESIDENCE
N 88°36'18" W 250.01'
SITE PLAN o 10 20 30 40FT
Ill = 1 01_On
go
9 p a u I aieIIo, p.s.
Pg. architecture + design
w
U
z
W
w
1z
z
I"1 >. O
W
O
IG Z Q
U W N
> > Z
0 " 0
a � G
V R- W
y1
PERMIT
SUBMITTAL
WALL ASSEMBLIES
W-1 WALL ASSEMBLY
• SIDING/ STAINED CEDAR or PAINTED HARDI PLANKS
• AIR & WATER BARRIER
• PLYWOOD SHEATHING
• WOOD WALL FRAMING, 2 X 6 TYP. SEE STRUCTURAL
• INSULATION R-21
• 1/2" GWB
• PAINT, VAPOR BARRIER
W-2 WALL ASSEMBLY
• SIDING/ STAINED CEDAR or PAINTED HARDI PLANKS
• AIR & WATER BARRIER
• PLYWOOD SHEATHING
• WOOD WALL FRAMING, 2 X 6 TYP. SEE STRUCTURAL
• PLYWOOD or GWB INT. FIN.
• STAIN/ SEALER
W-3 WALL ASSEMBLY
• WOOD / TILE FINISHES AT SELECTED LOCATIONS
• 1/2" GWB, PAINT OR
• 1/2" CEMENT BOARD AT WET LOCATIONS/ TILE BACKER
• WOOD WALL FRAMING, 2 X 4 or 2 x 6
• SOUND INSULATION
• 1/2" GWB, PAINT
W-4 WALL ASSEMBLY
(RESIDENCE/ GARAGE SEPARATION)
• 1/2" GWB (GARAGE SIDE), FIRE TAPED
• PLYWOOD SHEATHING
• WOOD WALL FRAMING, 2 X 6 TYP. SEE STRUCTURAL
• INSULATION R-21
• 1/2" GWB
• PAINT WARM SIDE VAPOR BARRIER
ROOF ASSEMBLIES
R-1 ROOF ASSEMBLY
• FACTORY FIN., GALV. STL 24 GA., STANDING SEAM ROOFING.
• SLIP SHEET AS REQUIRED
• ICE AND WATER SHIELD MEMBRANE
• PLYWOOD SHEATHING
• WOOD ROOF FRAMING TRUSSES OR RAFTERS - SEE
STRUCTURAL
• INSULATION R-49. CLOSED CELL INSULATION TO ACHIEVE
VAPOR BARRIER, NO VENTILATION REQUIRED, MANUFACTURER
REQ'D TO PROVIDE CERTIFICATE. (SEE BELOW)
REMAINDER OF INSULATION BATTS AS NEEDED TO MEET R-49
• 1/2" GWB
• PAINT
CLARIFICATION: NON VENTED ROOF/ ATTIC ASSEMBLY.
COMPRISED OF 3" MIN. OF AIR-IMPERMAEABLE SPRAY FOAM
zi INSULATION (R-21) "JM CORBOND III", ESR NO. 3159.
R-2 ROOF ASSEMBLY
• FACTORY FIN., GALV. STL 24 GA., STANDING SEAM
ROOFING.
• SLIP SHEET AS REQUIRED
• ICE AND WATER SHIELD MEMBRANE
• PLYWOOD SHEATHING
• WOOD ROOF FRAMING,TRUSSES OR RAFTERS - SEE
STRUCTURAL
• SOFFIT/ CEILING
• LINEAR VENT
• PAINT/ STAIN
R-3 ROOF ASSEMBLY
• FACTORY FIN., GALV. STL 24 GA., STANDING SEAM ROOFING.
• SLIP SHEET AS REQUIRED
• ICE AND WATER SHIELD MEMBRANE
• PLYWOOD SHEATHING
• WOOD ROOF FRAMING,TRUSSES OR RAFTERS - SEE
STRUCTURAL
TABLE R301.2(1)
CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
FLOOR/ CEILING ASSEMBLIES
-0 ----------------- o-
F-1 FLOOR ASSEMBLY
• 3/4" FINISHED FLOOR, WOOD FLOORING (OR TILE)
• PLYWOOD SHEATHING
• WOOD FLOOR FRAMING JOIST - SEE STRUCTURAL
• R-30 INSULATION
• CRAWLSPACE (VENTED) 18" MIN. CLR.
• VAPOR BARRIER, 6 MIL POLY SHEETING, TAPED
SEAMS AND EDGES
F-2 FLOOR ASSEMBLY
• 3/4" FINISHED FLOOR, WOOD FLOORING (OR TILE)
• PLYWOOD SHEATHING
• WOOD FLOOR FRAMING JOIST - SEE STRUCTURAL
• R-30 INSULATION (OVER UN-COND. SPACE)
• ACOUSTIC BATTS - OVER LIVING SPACE
• 1/2" GWB OR EXT SOFFIT
• LINEAR VENT @ EXTERIOR SOFFIT
• PAINT
F-3 FLOOR ASSEMBLY
• SEALER
• CONCRETE SLAB (SEE STRUCT.)
• VAPOR BARRIER, 6 MIL POLY
• 4" GRAVEL
• COMPACTED SUB -GRADE
INDOOR AIR QUALITY GENERAL NOTES::
THE PROPOSED PROJECT WILL UTILIZE AN INTEGRATED FORCED AIR FURNACE HEAT AND AIR DISTRIBUTION
SYSTEM. (REFER TO CODE SECTION M1507.3.5). CONTROLS AND OPERATIONS, SEE SECTION 1507.3.2
OUTDOOR AIR WILL BE SUPPLIED THROUGH AN OUT DOOR AIR SUPPLY TO THE FURNACE FAN. THE FURNACE
FAN AND THE EXHAUST FAN ARE TO BE INTEGRATED WITH A TIMER TO PROVIDE CODE MINIMUM AIR TO EACH
HABITABLE ROOM. INSURE ALL INTERIOR DOORS ARE UNDERCUT 1/2" MIN.
OUTDOOR AIR INLET(S), SEE M1507.3.5.3 FOR FULL DESCRIPTION. PRIMARY NOTE: OUTDOOR INLETS
SHALL BE SCREENED AND LOCATED SO AS NOT TO TAKE AIR FROM THE FOLLOWING AREAS:
1) CLOSER THAN 1 OFT FROM AN APPLIANCE VENT OUTLET, UNLESS SUCH VENT OUTLET IS 3 FT ABOVE THE
OUTDOOR AIR INLET.
PER TABLE M1507.3.3,(1) MIN. AIR FLOW RATE= 75 CFM, FOR CONTINUOUS OPERATION.
(2700 SF DWELLING, W/ (4) BEDROOMS)
UTILIZE CONTINUOUS OPERATION WHOLE HOUSE FAN WITH A MIN. OF 75 CFM. SEE PLAN A2.1 FOR LOCATION
OF EXHAUST FAN (LOCATED IN POWDER BATHROOM.)
SUBJECT
TO DAMAGE
FROM
ICE SHEILD
GROUND
WIND
SEISMIC
Frost
WATER
UNDER-
AIR
MEAN
SNOW
SPEEDe
DESIGN
line
DESIGN
LAYMENT
FLOOD
FREEZING
ANNUAL
LOAD
(mph)
CATEGORY9
Weatheringa
depth"
Termite
Decayd
TEMPT
REQUIRED'
HAZARDS"
INDEX)
TEMPk
Slight to
Firm Maps
25 psf
85
D1
Moderate
18"
S to M
27' F
No
0-1,000
50'
Moderate
11-8-99
• :A D • • 1111111111§114
ENERGY CODE GENERAL NOTES:
A) THE PROPOSED DWELLING IS TO MEET OR EXCEED THE PRESCRIPTIVE PATH PER PER W.S.E.C.,
2015 EDITION. TABLE 402.1.1. SEE TYPICAL ENVELOPE ASSEMBLIES AND WINDOW SCHEDULE FOR
ADDITIONAL NOTES.
B) DUCT LEAKAGE TEST RESULTS SHALL BE PROVIDED TO THE BUILDING INSPECTOR AND
HOMEOWNER PRIOR TO AN APPROVED FINAL INSPECTION.
C) AIR LEAKAGE SHALL BE LIMITED AND MEET WSEC 402.2. NOTE CREDIT CRITERIA BELOW.
PROVIDE A WRITTEN REPORT OF AIR LEAKAGE TEST RESULTS, SIGNED BY THE TESTING PARTY, TO
THE BUILDING INSPECTOR PRIOR TO APPROVED FINAL INSPECTION.
D) A RESIDENTIAL ENERGY COMPLIANCE CERTIFICATE COMPLYING WITH W.S.E.C. 105.4 IS
REQUIRED TO BE COMPLETED BY THE DESIGN PROFESSIONAL OR BUILDER AND PERMANENTLY
POSTED WITHIN 3' OF THE ELECTRICAL PANEL PRIOR TO FINAL INSPECTION.
E) DWELLING UNIT IS REQUIRED TO BE PROVIDED WITH AT LEAST ONE PROGRAMMABLE
THERMOSTAT FOR REGULATION OF TEMPERATURE.
F) MINIMUM OF 75% OF ALL INTERIOR LUMINAIRES SHALL BE HIGH EFFICACY LUMINAIRES. ALL
EXTERIOR LIGHTING SHALL BE HIGH EFFICACY LUMINAIRES.
G) ADDITIONAL ENERGY EFFICIENCY CREDITS OF 3.5 PER WSEC R.406:
(Medium sized dwelling unit.) ACHIEVED THROUGH A COMBINATION OF THE FOLLOWING OPTIONS.
OPTION 2b - 1.0 Credit: AIR LEAKAGE CONTROL & EFFICIENT VENTILATION:
(Whole house ventilation system with a minimum sensible heat recovery of .70)
(Air leakage test of 2.0 Air Changes/Hour max.)
OPTION 3B - 1.0 Credit: HIGH EFFICIENCY HVAC EQUIPMENT
(Air source Heat pump with a min. HSPF of 9.0)
OPTION 5c - 1.5 Credits: HIGH EFFICIENCY WATER HEATING.
(Gas water heater with a minimum of of of .91)
WINDOW & EXT. DOOR SCHEDULE:
R n 1;17F APPRny (7" +/-1 cnNCI II T W/ MANI IF MIN
NO.
STYLE
W x" x
H
AREA (SI)
AREA SF
U VALUE
NOTES
1
PATIO SLIDER Assembly
74" x
111"
8,214
57.0
0.30
1,2
2
PICTURE Assembly
38" x
72"
2,736
19.0
0.30
3
PATIO SLIDER Assembly
160" x
111"
17,760
123.3
0.30
1
4
PATIO SLIDER Assembly
160" x
111"
17,760
123.3
0.30
1
5
CASEMENT PAIR
72" x
72"
5,184
36.0
0.30
1
6
PATIO SLIDER Assembly
74" x
111"
8,214
57.0
0.30
1
7
PICTURE
38" x
72"
2,736
19.0
0.30
1
8
CASEMENT PAIR
72" x
72"
5,184
36.0
0.30
9
CASEMENT
36" x
56"
2,016
14.0
0.30
2
10
CSMT/ PICTURE/ CSMT
108" x
56"
6,048
42.0
0.30
11
PICTURE
30" x
96"
2,880
20.0
0.30
1
12
FRONT DOOR
44" x
96"
4,224
29.3
0.30
1
13
PICTURE
30" x
96"
2,880
20.0
0.30
1
14
AWNING/PICTURE STACKED
24" x
65"
1,560
10.8
0.30
3
15
NOT USED
F
16
DOOR
38" x
86"
3,268
22.7
0.30
17
AWNING TRIPLE
90" x
24"
2,160
15.0
0.30
18
CASEMENT
24" x
36"
864
6.0
0.30
3
19
CASEMENT
24" x
36"
864
6.0
0.30
3
20
AWNING TRIPLE
90" x
24"
2,160
15.0
0.30
1
21
CSMT/ PICTURE/ CSMT
108" x
56"
6,048
42.0
0.30
2
22
CSMT/ PICTURE/ CSMT
108" x
56"
6,048
42.0
0.30
1
23
CSMT/ PICTURE/ CSMT
108" x
56"
6,048
42.0
0.30
2
24
CASEMENT
36" x
56"
2,016
14.0
0.30
25
CASEMENT
36" x
32"
1,152
8.0
0.30
26
CSMT/ PICTURE/ CSMT
108" x
32"
3,456
24.0
0.30
27
CASEMENT
36" x
32"
1,152
8.0
0.30
1,3
28
AWNING TRIPLE
108" x
16"
1,728
12.0
0.30
1
29
CASEMENT
24" x
32"
768
5.3
0.30
30
ICASEMENT
1 24" x
32"
768
5.3
0.30
TOTAL AREA
NOTES:
* U-VALUES LISTED SHALL BE LABELED ON THE FENESTRATION & CERTIFIED IN ACCORDANCE W/ NFRC 100.
PROVIDE OPTIONS FOR SCREENING AT ALL OPENING
1) GLASS TO MEET SAFETY GLAZING REQUIREMENTS
2) UNIT TO MEET EGRESS REQUIREMENTS OF THE IRC.
3) OBSCURE GLASS
DOOR
NO. LOCATION DOOR SLAB SIZE STYLE OPERATION JAMB
HARDWARE CYLINDER BORE DIA.
handset type 2 3/8 BACKSET verify DEADBOLT MISC., NOTES
1
GARAGE
T-0" X 7'-0"
FLUSH
SWING
7"
1
PASSAGE
2 1/8"
1
SELF CLOSING, FIRE RATED
2
LAUNDRY
2'-8" X 7'-0"
FLUSH
SWING
4 1/2"
1
PASSAGE
2 1/8"
-
3
1/2 BATHROOM
2'-4" X 7'-0"
FLUSH
SWING
4 1/2"
1
PASSAGE/ PRIVACY
2 1/8"
-
4
HALL CLOSET
2 2'-0" X 7'-0"
FLUSH
PAIR SWING
4 1/2"
1
DUMMY SET
-
-
TOP BALL CATCH es
5
COAT CLOSET
2 2'-0" X 7'-0"
FLUSH
PAIR SWING
4 1/2"
1
DUMMY SET
-
-
TOP BALL CATCH es
6
DEN
2'-8" X 7'-0"
FLUSH
SWING
5"
1
PASSAGE
2 1/8"
-
7
DEN CLOSET
2'-4" X 7'-0"
FLUSH
SWING
4 1/2"
1
PASSAGE
2 1/8"
-
8
UNDERSTAIR
2'-6" X 5'-0"
FLUSH
SWING
4 1/2"
1
PASSAGE
2 1/8"
-
KEYED LOCK? TBD
9
MASTER VESTIBU
T-0" X 7'-0"
FLUSH
SWING
4 1/2"
1
PASSAGE
2 1/8"
-
10
EXTRA CLOSET
2'-4" X 7'-0"
FLUSH
SWING
4 1/2"
1
PASSAGE
2 1/8"
-
11
MASTER BR
2'-8" X 7'-0"
FLUSH
SWING
4 1/2"
1
PASSAGE
2 1/8"
-
12
MASTER CLOSET
2'-4" X 7'-0"
FLUSH
SWING
4 1/2"
1
PASSAGE
2 1/8"
-
13
MASTER BATH
2'-8" X 7'-0"
FLUSH
SWING
4 1/2"
1
PASSAGE/ PRIVACY
2 1/8"
-
14
WATER CLOSET
2'-6" X 7'-0"
FLUSH
POCKET
6 1/2"
-
RECESSED CUP
-
-
POCKET DOOR HW
15
NOT USED
16
S BR CLOSET
2 2'-0" X 7'-0"
FLUSH
PAIR SWING
4 1/2"
1
DUMMY SET
2 1/8"
-
TOP BALL CATCH es
17
SOUTH BEDROOM
2'-8" X 7'-0"
FLUSH
SWING
4 1/2"
1
PASSAGE
2 1/8"
-
18
BATH
2'-6" X 7'-0"
FLUSH
SWING
4 1/2"
1
PASSAGE/ PRIVACY
2 1/8"
-
19
NORTH BEDROOM
2'-8" X 7'-0"
FLUSH
SWING
4 1/2"
1
PASSAGE
2 1/8"
-
20
N BR CLOSET
2 2'-0" X 7'-0"
FLUSH
PAIR SWING
4 1/2"
1
DUMMY SET
2 1/8"
-
TOP BALL CATCH es
18
1
►ee
pal aiello, p.s.
chitecture + desi n
9
7818
REGISTERED
ARCHITECT
PAUL AIELLO
STATE OF WASHINGTON
w
V
IZ
w
0
Vi
w
Z
CD
0. CV
CD
Q
a a
0 0
V W
03.24.2020 (Intake)
06.05.2020 (correction 1)
: TYPICAL WALL/ ROOF/
: FLOOR ASSEMBLIES
: WNDO SCHEDULE
: INT. DOOR SCHEDULE
: ENERGY NOTES
GENERAL NOTES:
A. ALL TEMPORARY SHORING, EXCAVATIONS STABILITY AND
CONSTRUCTION MEANS AND METHODS SHALL BE THE SOLE
RESPONSIBILITY OF THE GENERAL CONTRACTOR.
B. SCALING OF DRAWINGS SHOULD BE USED FOR REFERENCE
PURPOSES ONLY. VERIFY WITH ARCHITECT.
C. SEE S2.0 FOR FOUNDATION AND STRUCTURAL
PLAN NOTES:
1. GUARDS: TOP OF GUARD AT 36" ABOVE WALKING SURFACE WITH
MAXIMUM OPENING OF 4".
2. HANDRAIL: 1 1/2" DIA HANDRAIL MOUNTED AT 34" ABOVE THE LINE
OF THE NOSING. RETURN END TO WALL OR NEWEL
3. STAIRS: MAX RISE 7 3/4", MIN. TREAD 10". 6'8" MIN. HEAD ROOM. 36"
MIN. WIDTH
4. ANY ENCLOSED STORAGE AREA BELOW STAIRS REQUIRES 1/2" GWB
FIRE PROTECTION
5. MECHANICAL SYSTEMS REQUIRE SEPARATE PERMIT. INSURE ALL
VENTILATION REQUIREMENTS MEET ALL CURRENT CODES. SEE
ENERGY CODE NOTES A4.2
6. SAFETY GLAZING REQUIRED - SEE WINDOW SCHEDULE
7. EGRESS (EMERGENCY ESCAPE AND RESCUE OPENINGS) WINDOW
REQUIRED -SEE WINDOW SCHEDULE.
NOTE: SEE IRC SECTION 310 FOR COMPLETE DESCRIPTION.
MINIMUM OPENING AREA 5.7 SF, SILL 44" MAX. ABOVE FINISHED
FLOOR.
8. ACCESS PANEL (22" X 30" MIN.) REQUIRED TO ALL ENCLOSED
SPACES WITH 30" HEAD ROOM. INSULATED/ GASKETED IF IN
INSULATED ASSEMBLY.
9. VENT HOT WATER TANK RELIEV FALVE DIRECTLY TO THE OUTSIDE,
PROVIDE SEISMIC STRAPS WITHIN UPPER 1/3 AND LOWER 1/3 OF
HOT WATER TANK, PROVIDE EXPANSION TANK.
10. SOURCES OF IGNITION FOR GAS HOT WATER TANK AND FURNACE TO
BE LOCATED 18"A.F.F. MIN., OR LABLED FVIR.
11. INSTALL DIRECT -VENT MANUFACTURED GAS FIREPLACE IN
ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AND ALL
APPLICABLE CODES.
12. DRYER TO VENT DIRECTLY TO THE OUTSIDE WITH A MAXIMUM VENT
LENGTH OF 25' AND A MAXIMUM OF (2) 90° ELBOWS.
13. PROVIDE PRESSURE REDUCING VALVE AND MAIN WATER SHUT-OFF
ON WATER SUPPLY LINE. COORDINATE WITH CIVIL ENGINEER AND
�FIRESPRIIVKLER SYS M.
14. KITCHEN HOOD PROPSED 300 CFM. IF HOOD CFM EXCEES 400 CFM,
THEN MAKE-UP AIR WILL BE REQUIRED
15. DRYER VENTAND LAUNDRY FAN COMBINATION NOT TO EXCEED
MANUFACTURER'S SPECIFICATIONS OR MAKE-UP AIR WILL BE
REQUIRED.
PLAN KEY
NEW EXT WALL: 2X6 DF #2 STUDS @
16" O.C. W/ R-21 INSUL.
NEW INT. WALL: 2X6 DF #2 STUDS @
16" O.C.
NEW INT. WALL: 2X4 DF #2 STUDS @
16" O.C.
•--------------• ITEM BELOW
— — — — ITEM ABOVE
O WINDOWS & EXTERIOR DOORS -
SEE SCHEDULE A1.1
O INTERIOR DOORS & HARDWARE
SEE SCHEDULE,A1.1
SMOKE DETECTOR & CARBON
SDI MONOXIDE DETECTOR -HARDWIRED
FAN W/ CFM AS NOTED - FOLLOW ALL
CURRENT MECHANICAL CODES -
SWITCHED W/ TIMERS
#7. PLAN NOTE - SEE LIST
WALL, ROOF OR FLOOR TYPE
SEE SHEET A 1.1
I ST FLOOR PLAN
1 /411 = 1 I-011
1 2 3 4 4 5 6 7
64'
2"
7'-8"
15'-0"
11 '-8"
31-4"
2'-6"
24'-0"
,,---EAVE ABOVE TYP.
8 FEET
0 or
pauI aiello, p.s.
j architecture + design
w
U
z
w
0
w
m
z
O
a
Sao
Co
Z Q
U w
Z
pR, o
lz
U �- W
PERMIT
SUBMITTAL
3/27/2020 INTAKE
GENERAL NOTES:
A. ALL TEMPORARY SHORING, EXCAVATIONS STABILITY AND
CONSTRUCTION MEANS AND METHODS SHALL BE THE SOLE
RESPONSIBILITY OF THE GENERAL CONTRACTOR.
B. SCALING OF DRAWINGS SHOULD BE USED FOR REFERENCE
PURPOSES ONLY. VERIFY WITH ARCHITECT.
C. SEE S2.0 FOR FOUNDATION AND STRUCTURAL
PLAN NOTES:
1. GUARDS: TOP OF GUARD AT 36" ABOVE WALKING SURFACE WITH
MAXIMUM OPENING OF 4".
2. HANDRAIL: 1 1/2" DIA HANDRAIL MOUNTED AT 34" ABOVE THE LINE
OF THE NOSING. RETURN END TO WALL OR NEWEL
3. STAIRS: MAX RISE 7 3/4", MIN. TREAD 10". 6'8" MIN. HEAD ROOM. 36"
MIN. WIDTH
4. ANY ENCLOSED STORAGE AREA BELOW STAIRS REQUIRES 1/2" GWB
FIRE PROTECTION
5. MECHANICAL SYSTEMS REQUIRE SEPARATE PERMIT. INSURE ALL
VENTILATION REQUIREMENTS MEET ALL CURRENT CODES. SEE
ENERGY CODE NOTES A4.2
6. SAFETY GLAZING REQUIRED -SEE WINDOW SCHEDULE
7. EGRESS (EMERGENCY ESCAPE AND RESCUE OPENINGS) WINDOW
REQUIRED -SEE WINDOW SCHEDULE.
NOTE: SEE IRC SECTION 310 FOR COMPLETE DESCRIPTION.
MINIMUM OPENING AREA 5.7 SF, SILL 44" MAX. ABOVE FINISHED
FLOOR.
8. ACCESS PANEL (22" X 30" MIN.) REQUIRED TO ALL ENCLOSED
SPACES WITH 30" HEAD ROOM. INSULATED/ GASKETED IF IN
INSULATED ASSEMBLY.
9. VENT HOT WATER TANK RELIEV FALVE DIRECTLY TO THE OUTSIDE,
PROVIDE SEISMIC STRAPS WITHIN UPPER 1/3 AND LOWER 1/3 OF
HOT WATER TANK, PROVIDE EXPANSION TANK.
10. SOURCES OF IGNITION FOR GAS HOT WATER TANK AND FURNACE TO
BE LOCATED 18"A.F.F. MIN., OR LABLED FVIR.
11. INSTALL DIRECT -VENT MANUFACTURED GAS FIREPLACE IN
ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AND ALL
APPLICABLE CODES.
12. DRYER TO VENT DIRECTLY TO THE OUTSIDE WITH A MAXIMUM VENT
LENGTH OF 25' AND A MAXIMUM OF (2) 90° ELBOWS.
13. PROVIDE PRESSURE REDUCING VALVE AND MAIN WATER SHUT-OFF
ON WATER SUPPLY LINE. COORDINATE WITH CIVIL ENGINEER AND
FIRE SPRINKLER SYSTEM.
PLAN KEY
NEW EXT WALL: 2X6 DF #2 STUDS @
16" O.C. W/ R-21 INSUL.
NEW INT. WALL: 2X6 DF #2 STUDS @
16" O.C.
NEW INT. WALL: 2X4 DF #2 STUDS @
16" O.C.
•--------------• ITEM BELOW
— — — — ITEM ABOVE
O WINDOWS & EXTERIOR DOORS -
SEE SCHEDULE A1.1
O INTERIOR DOORS & HARDWARE
SEE SCHEDULE,A1.1
SMOKE DETECTOR & CARBON
SDI MONOXIDE DETECTOR -HARDWIRED
FAN W/ CFM AS NOTED - FOLLOW ALL
CURRENT MECHANICAL CODES -
SWITCHED W/ TIMERS
#7. PLAN NOTE - SEE LIST
WALL, ROOF OR FLOOR TYPE
SEE SHEET A 1.1
0
Wo
A
❑m
w
1 /4" = 1 `-V"
1 2 3 4 4 5 6 7
64'
2"
7'-8"
15'-0"
11 '-8"
31-4"
2'-6"
24'-0"
11
paul aiello, p.s.
architecture + design
7818
REGISTERED
C -tARCFITECT AIELLO
WASHINGTON
w
U
z
w
0
w
m
z
O
a
Sao
Co
Z Q
U w m
..
Z
pR, o
lz
U �- W
A
Z
PERMIT
SUBMITTAL
0
We
4.2
w
1 /4" = 1 `-V"
B
4.2
4.2
P % %
paul aiello, p.s.
0 j architecture design
7818
FARCFJITECT
STERED
'
PAUL AIELLO
STATE OF WASHINGTON
w
V
z
w
Y!
w
It
z
0
ada
o
Qom
zQ
V W N
..
z
0 R. 0
a � G
V �. W
PERMIT
SUBMITTAL
247.2'
2nd Floor
238.8'
1 st Floor
WEST ELEVATION
11411 = 1'-0"
F1
IL
SOUTH ELEVATION
114" = 1 `-O"
P % %
paul aiello, p.s.
j architecture +design
7818
REGISTERED
C -tARCFITECT
AIELLOWASHINGTON
w
V
z
w
0
w
m
z
O
a
Sao
z Q
� Q
U w m
..
z
0 0
a � o
U �- W
U)
z
o° OEM
a
w>
1=0 w
x J
W W
PERMIT
SUBMITTAL
A B C D E
15'-0" 15'-0" 15'-0" 15'-0"
EAST ELEVATION
1 /4" = 1 1-V'
17
24'-0"
NORTH ELEVATION
1/4" = 1'-0"
6 5 4
2'-6" 31-4"
3 2 1
11'-8" 15'-0" 7'-8"
paul aiello, p.s.
j architecture +design
7818
REGISTERED
C -tARCFITECT
AIELLOWASHINGTON
w
V
z
W
I�
i�
W
m
z
O
a
Sao
za
U w m
..
z
0 0
a � o
U �- W
U)
z
o° OEM
a
w
>
1=0
w
x
J
W
W
PERMIT
SUBMITTAL
SECTION NOTES:
A. FOR WALL, FLOOR & ROOF TYPES,
REFER TO SHEET A1.1
B. SCALING OF DRAWINGS SHOULD BE
USED FOR REFERENCE PURPOSES
ONLY. VERIFY WITH ARCHITECT.
C. SEE S2.0 FOR FOUNDATION AND
STRUCTURAL
n
W
248.2'
2nd Floor
238.8'
1 st Flc
15'-0"
15'-0"
BEDROOM
zz� L
DEN / LIVING ROOM
/ BEYOND
'ILIF1
SECTION TO WEST
1/4" = 1'-O"
C
15'-0"
HALLWAY
..ws � I I VESTIBULE
15'-0"
R1
F2 BEDROOM
MASTER
CLOSET
F1
774 1
E
O 2 4 8 FEET
W
_
w
=
J
0
O
LO
Q
=
N
O
J
0I
J
o
D-
N
o
237.65'
RAGE GRADE
2 or
01111 paul aiello, p.s.
j architecture + design
7818
REGISTERED
C — ' ARCHITECT
PAUL AIELLO
STATE OF WASHINGTON
w
U
z
W
I�
i�
W
m
z
O
a
Sao
za
U w
z
0 0
a � o
U �- W
�N
z z
-o
o�
= U
� W
m tlf
PERMIT
SUBMITTAL
1 2 3
7'-8" 15'-0" 11 '-8"
4 5 6
31-4" 2'-6" 24'-0"
7
SECTION NOTES:
A. FOR WALL, FLOOR & ROOF TYPES,
REFER TO SHEET A1.1
B. SCALING OF DRAWINGS SHOULD BE
USED FOR REFERENCE PURPOSES
ONLY. VERIFY WITH ARCHITECT.
C. SEE S2.0 FOR FOUNDATION AND
STRUCTURAL
248.2'
2nd Floor
238.8'
1st Floor
T-0"
A O.H.
CHIMNEY
TRUSS & INSULATED ATTIC --
R1 5•
5.1
IIII IIII�I_III____I_III,\III ��i
c
5.1
SECTION TO NORTH THRU LIVING ROOMS ENTRY &GARAGE
A.J / 1/4" = 1'-O"
248.2'
2nd Floor
LU
+CD a
U_
0 00
H
238.8'
1st Floor
i�
\1\ 2 3
7'-8" 15'-0"
CHIMNEY
BEYOND
F
I
I
5.
\ \
\ \
b)
J
W
U
R1
I I =1LERNE I
C
R1
Cl
5 6
31-4" 2'-6"
I�
IN
CRAWL SPACE
SECTION TO NORTH THRU KITCHEN & DEN
`oi* 1 1 /4" = 1 '-O"
Z�
ICD
5.1
24'-0"
\
/
DRIVEWAY
h
2'-0"
O.H.
237.65'
GRADE
O 2 4
H
2
C�
W
LU
LD
c
m
LU
Q
=
N
O
J
60
LU
J
Q
o
C
N
O
237.65'
WERAGlt GRADE
8 FEET
O 2 4 8 FEET
0 or
pauI aiello, p.s.
j architecture + design
7818
REGISTERED
C -tARCFITECT
AIELLOWASHINGTON
w
U
z
W
w
M
z
a
o
Sao
Z Q
� 4
U w �'
Z
pR, o
U �- W
() U)
z z
-o
Q 1=0
- U
7 W
m N
PERMIT
SUBMITTAL
ROOFING MATERIAL: ALT. 1
STANDING SEAM METAL W/ ICE AND
WATER SHIELD - SEE SPEC
ROOFING MATERIAL: ALT. 2
GRANULAR CAP SHEET
MEMBRANE SYSTEM, SEE SPEC.
DRIP
FLASHING
CONT.-
GUTTER - ------ -_
— —
r I F-1
CEDAR FASCIA,
STAINED
DOWNSPOUT AND
STANDOFF, CONNECT
TO TIGHTLINE
CEDAR T & G SOFFIT, STAINED
AND SEALED
HARDI PANEL FRIEZE BOARD,
PAINTED
CEDAR TRIM @ BEAM, ALIGN
WITH WINDOW HEAD TRIM
WINDOWS - FLANGED
ASSEMBLIES SEALED F
MANUF. SPECS, SEE
SCHEDULE
A. ROOF
DOWNSPOUT TIGHT LII
APPROVED DISCHARG
CIVIL
PATIO PAVERS WITH
UNDERDRAIN, TBD.
2" SETTING SAND
COURSE OVER 3"
DRAINAGE GRAVEL
COURSE, TBD
DRAINAGE ROCK, DRA
LINE, AND FOOTING DF
AT PERIMETER, SEE Cl
REINF. CONCRETE STE
WALLAND FOOTING/ G
BEAM. SEE S2.0
STEEL PIN PILES. SEE
FOUNDATION PLAN S2.
C. FLOOR SILL FOUNDATION
Co
R-1 ROOF ASSEMBLY
CLOSED CELL INSULATION TO
ACHIEVE VAPOR BARRIER, NO
VENTILATION REQUIRED,
MANUFACTURER REQ'D TO
PROVIDE CERTIFICATE.
REMAINDER OF INSULATION
BATTS AS NEEDED TO MEET R-49
PREMANUF. TRUSS WITH
TOP CHORD BEARING.
SLOPING TOP AND FLAT
CEILING BOTTOM
DRAPERY OR
SHADE POCKET
1/2" GWB CEILING
FURRING AS NEEDED
3/4 X 2 1/2" HEAD TRIM W/
1/2" REVEAL TO CLG
FLASHING PAN AND
WATERPROOFING AT/
BELOW SILL, WRAP
MATERIAL 6" UP EACH JAMB
CONDITION
F-1 FLOOR ASSEMBLY
FINISHED FLOORING
(WOOD OR TILE)
R-30 FLOOR INSULATION
FLOOR FRAMING SYSTEM
SEE S2.1
CRAWLSPACE, 24" TYPICAL
(18" MIN. CLEAR).
VAPOR BARRIER AND
GRAVEL
R(1(1FIN(, NAATr:PIAI Al T 1
S,
W
R,
G
M
D
FI
C
S
C
AI
H
R
r
U
A
M
Sl
C
S
C
H. - -
OVER WEATHER BARRIER
R-21 WALL INSULATION (HI
BATTS)
SCREENED FOUNDATION
VENT 8" X 16" WITH GRATE
WELL, SEE FOUNDATION
PLAN S1.0 FOR LOCATION:
DRAINAGE ROCK, DRAIN
LINE, AND FOOTING DRAIN
AT PERIMETER, SEE CIVIL
REINF. CONCRETE STEM
WALLAND FOOTING/ GRAC
BEAM. SEE S2.0
STEEL PIN PILES. SEE
FOUNDATION PLAN S2.0
D. FLOOR SILL FOUNDATION
R-1 ROOF ASSEMBLY
CLOSED CELL INSULATION TO
ACHIEVE VAPOR BARRIER, NO
VENTILATION REQUIRED,
MANUFACTURER REQ'D TO
PROVIDE CERTIFICATE.
REMAINDER OF INSULATION
BATTS AS NEEDED TO MEET R-49
PREMANUF. TRUSS WITH
TOP CHORD BEARING.
SLOPING TOP AND FLAT
CEILING BOTTOM
DRAPERY OR
SHADE POCKET
1/2" GWB CEILING
FURRING AS NEEDED
3/4 X 2 1/2" HEAD TRIM W/
1/2" REVEAL TO CLG
F-1 FLOOR ASSEMBLY
FINISHED FLOORING
(WOOD OR TILE)
R-30 FLOOR INSULATION
FLOOR FRAMING SYSTEM
SEE S2.1
CRAWLSPACE, 24" TYPICAL
(18" MIN. CLEAR).
VAPOR BARRIER AND
GRAVEL
paul aiello, p.s.
architecture + design
7818
REGISTERED
ARCHITECT
i
PAUL AIELLO
STATE OF WASHINGTON
w
V
Iz
w
0
Vi
w
Q�
z
I..I
a c
O
x 00
3
q
0 C
V W
03.24.2020
A. - - - - - - - - - - - --
-------------
DETAILS
DRIP
FLASHING
CONT.
GUTTER
CEDAR FASCIA,
STAINED
ROOFING MATERIAL: ALT. 1
STANDING SEAM METAL W/ ICE AND
WATER SHIELD - SEE SPEC
ROOFING MATERIAL: ALT. 2
GRANULAR CAP SHEET
MEMBRANE SYSTEM, SEE SPEC.
DOWNSPOUT AND
STANDOFF, CONNECT
TO TIGHTLINE
CEDAR T & G SOFFIT, STAINED
AND SEALED
HARDI PANEL FRIEZE BOARD,
PAINTED
CEDAR TRIM @ BEAM, ALIGN
WITH WINDOW HEAD TRIM
E. ROOF LOWER EAVE
R-2 ROOF ASSEMBLY
O
O
R-1 ROOF ASSEMBLY
CLOSED CELL INSULATION TO
ACHIEVE VAPOR BARRIER, NO
VENTILATION REQUIRED,
MANUFACTURER REQ'D TO
PROVIDE CERTIFICATE.
REMAINDER OF INSULATION
BATTS AS NEED TO MEET R-49
SEE DTL A/ A5.1, SIM.
CONDITION AND NOTES
FLASHING PAN AND
WATERPROOFING AT/
BELOW SILL, WRAP
MATERIAL 6" UP EACH JAMB
CONDITION
COUNTER FLASHING
ROOFING HEAD CAP FLASHING
WITH FOAM CLOSURE
R-1 ROOF ASSEMBLY
1. ROOF to WALL Tran!
J. FLOOR to WALL Tra
O
G. ROOF UPPER EAVE
H . ROOF to WALL Transition
=LANGED
SEALED PER
-�S, SEE
LL ASSEMBLY
LL ASSEMBLY
)OR ASSEMBLY
ROOFING HEAD CAP
FLASHING WITH FOAM
CLOSURE
DRIP
FLASHING
CEDAR FASCIA,
STAINED
CEDAR T & G SOFFIT, STAINED
AND SEALED
W-1 WALL ASSEMBLY
paul aiello, p.s.
architecture + design
7818
REGISTERED
ARCI-1TECT
PAUL AIELLO
STATE OF WASHINGTON
COUNTER FLASHING
ROOFING HEAD CAP FLASHING
WITH FOAM CLOSURE
R-1 ROOF ASSEMBLY
W-3 WALL ASSEMBLY
W
V
z
W
0
V1
W
z
I�
a
c
�o
�00
0
0
V
W
03.24.2020
. - - - - - - - - - - - - -
DETAILS
STRUCTURAL NOTES=
CODE:
CODE: INTERNATIONAL BUILDING CODE 2015, ASCE/SEI 1-10
LOADS: ROOF LIVE= 20 PSF, ROOF SNOW= 25 PSF, FLOOR LIVE= 40 PSF
ROOF DEAD = 15 PSF, FLOOR DEAD= 12 PSF
SEIS: GROUP I, CATEGORY 'D',
R= 65 (WOOD FRAME WALL SHT'G W/ STRUCTURAL PANELS)
Ss = 1216 g, S 1 = 0501 g, SD$= OB52, Sol = 0501
WIND: 85 MPH, EXPOSURE 'B', K, = 1.00
FOUNDATIONS:
ALL EXTERIOR FOOTINGS SHALL EXTEND A MINIMUM OF I'-6' BELOW ADJACENT EXTERIOR
FINISHED GRADE. MINIMUM DESIGN EQUIVALENT FLUID PRESSURE IS 50 PCF PER REPORT
FROM Associated Earth Science, Inc. (Jan. 10, 2020 Project No. 20190294E000.
SEE THE REPORT FOR REQUIREMENT AND RECOMMENDATION.
CAST- IN -PLACE CONCRETE:
F'c=2,500 PSI a 28 DAYS. MINIMUM 5-1/2 SACKS OF CEMENT PER CUBIC YARD OF CONCRETE
AND SHALL BE PROPORTIONED TO PRODUCE A SLUMP OF 5' OR LESS. MAXIMUM SIZED
AGGREGATE IS 1-1/2 INCHES. CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED
IN ACCORDANCE WITH IBC SECTION 1905,1906 ANDACI 301, INCLUDING TESTING PROCEDURES.
ALL PHASES OF WORK PERTAINING TO THE CONCRETE CONSTRUCTION SHALL CONFORM TO THE
BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE. ALL REINFORCING STEEL DOWELS,
ANCHOR BOLTS AND OTHER INSERTS SHALL BE SECURED IN POSITION PRIOR TO POURING CONC.
REINFORCING STEEL:
ALL REINFORCING STEEL SHALL BE PLACED IN CONFORMANCE WITH THE BUILDING CODE
REQUIREMENTS FOR REINFORCED CONCRETE AND THE MANUAL OF STANDARD PRACTICE
FOR REINFORCED CONCRETE CONSTRUCTION BY CRSI. DEFORMED REINFORCING STEEL BARS
SHALL CONFORM TO ASTM GRADE 60. ALL REINFORCING BAR BENDS SHALL BE MADE COLD,
WITH A MINIMUM RADIUS OF 6 BAR DIAMETERS (I'-1' MINIMUM). CORNER BARS (2'-O' BEND)
SHALL BE PROVIDED FOR ALL HORIZONTAL REINFORCEMENT. LAP ALL BARS A MINIMUM
OF 48 BAR DIAMETERS UNLESS NOTED OTHERWISE. UNLESS OTHERWISE NOTED ON THE
DRAWINGS REINFORCING STEEL SHALL HAVE THE FOLLOWING MINIMUM COVER:
CONCRETE CAST AGAINST EARTH 3'
CONCRETE EXPOSED TO EARTH OR WEATHER: 111/2'
CONCRETE NOT EXPOSE TO EARTH OR WEATHER:
MI BAR AND SMALLER 3/4'
SLAB -ON -GRADE (FROM TOP SURFACE) 111/2'
PROVIDE 2-05 EXTRA BARS EXTENDING 25' (MIN) BEYOND CORNERS AT TOP, BOTTOM
AND EACH SIDE OF OPENING.
STRUCTURAL TIMBER:
ALL GRADES SHALL CONFORM TO WWPA GRADING RULES FOR WESTERN LUMBER, LATEST EDITION.
PROVIDE CUT WASHERS UNDER ALL NUTS AND BOLTS BEARING AGAINST WOOD. ALL WOOD IN
CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED.
ALL STRUCTURAL LUMBER SHALL BE NOTED BELOW:
2x6, 2x8, 2x10, 2x6 SILL IE, bxb POST DOUGLAS-FIR / LARCH 02
LUMBER NOT NOTED HEM -FIR 02
MISCELLANEOUS HANGERS TO BE SIMPSON OR APPROVED EQUAL. ALL HANGERS SHALL BE
FASTENED TO WOOD WITH MAXIMUM NAILS -ALL HOLES SHALL BE NAILED. ALL NAILS SHALL
BE COMMON WIRE NAILS. PROVIDE NAILING SHALL BE IN ACCORDANCE WITH 'I.B.C. 2015'
TABLE 2304.10.1 FASTENING SCHEDULE.
PLY111002 OR OSB WEB JOISTS:
JOISTS ARE SHOWN ON PLANS A 'TJI' TO BE TRUS JOIST OR EQUAL. JOIST ASSEMBLY TO TESTED
UNDER 'IBC 2012' TESTING PROCEDURES. COMPLETE JOIST DESIGNS BEARING THE STAMP
OF A REGISTERED PROFESSIONAL ENGINEER TO BE SUBMITTED FOR REVIEW. JOIST
MANUFACTURER SHALL PROVIDE ALL SPECIALTY ITEMS FOR A NORMAL AND COMPLETE
INSTALLATION OF THE JOISTS. INSTALL DOUBLE JOISTS UNDER PARTITIONS EXTENDING ONE HALF
OR MORE OF JOIST SPAN.
GLUED -LAMINATED TIMBER:
LAMINATED TIMBER SHALL BE DOUGLAS-FIR/LARCH KILN DRIED. STRESS GRADE
COMBINATION 24F-V4 (Fb=2,400 PSI, Fv=I(o5 PSI) FOR SIMPLE SPANS AND 24F-VS
FOR CANTILEVERED AND CONTINUOUS BEAMS. A.I.T.C. CERTIFICATE OF CONFORMANCE
REQUIRED. GLU-LAMS SHALL CONFORM TO A.I.T.C. STANDARDS 111. FABRICATOR SHALL
SUBMIT DETAILS AND SPECIFICATIONS TO THE ENGINEER AND BUILDING DEPARTMENT
FOR APPROVAL PRIOR TO FABRICATION. CAMBER 2000 FT RADIUS.
MacMILLAN PARALLAM (PSL):
PARALLAM SHOWN ON PLAN TO BE TRUS JOIST MacMILLAN'S PARALLAM 22E OR APPROVAED
EQUAL. OTHER THAN MacMILLAN'S PARALLAM 22E SHALL HAVE ICBO APPROVALS SUBMITTED
TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR REVIEW.
Fb=2,900 psi., Fv = 290 psi, Fc= 650 psi, E= 2,200000 psi.
ROOF 4 FLOOR SHEATHING:
ROOF SHEATHING SHALL BE 1/2' A.P.A. RATED SHEATHING. SPAN RATING 32/Ib, INSTALLED WITH
LONG DIMENSION ACROSS SUPPORTS. PANEL END JOINTS SHALL OCCUR AT SUPPORTS. NAIL AT
PANEL EDGES WITH 10d COMMON (z0.148'0x2''/2') a 6' O.C. AND 12' O.C. AT INTERMEDIATE SUPPORTS.
FLOOR SHEATHING SHALL BE 3/4' T4G SPAN RATING 40/20 WITH 10d COMMON * 6' O.C. (EDGE)
AND 10' O.C. (INTERM). USE "10 SCREWS (21/2' LONG) IN LIEU OF 10d COMMON NAILS AT FLOOR
CONTRACTOR'S OPTION. INSTALL PLYWOOD CLIP AT 48 INCHES ON CENTER BLOCKING IS REQ'D
ALL PANEL EDGES.
WALL SHEATHING:
SHEATHING SHALL BE 1/2' A.P.A. RATED SHEATHING, SPAN RATING 24/0. PANEL END JOINTS
SHALL OCCUR AT SUPPORTS. NAIL PANEL EDGES WITH 8d COMMON NAILS AT 6 INCHES ON
CENTER AND 12 INCHES ON CENTER AT INTERMEDIATE SUPPORT UNLESS NOTED OTHERWISE
ON THE SHEAR WALL SCHEDULE.
BEARING WALL FRAMING:
ALL DOOR AND WINDOW HEADERS NOT CALLED OUT ON THE PLANS SHALL BE W-2x6 DF 02 WITH
ONE CRIPPLE AND ONE STUD EACH END FOR OPENINGS 4 FEET OR LESS AND TWO CRIPPLES 4 ONE STUD
FOR OPENINGS MORE THAN 9 FEET WIDE. ALL COLUMNS NOT CALLED OUT ON THE PLANS SHALL BE
(2) STUDS MINIMUM. PROVIDE MAXIMUM STUD UNDER WOOD BEAM. SPIKE LAMINATED COLUMNS TOGATHER
WITH Ibd NAILS AT 12 INCHES ON CENTER PROVIDE TWO LAYERS OF ASPALT IMPREGNATED BUILDING
PAPER AT CONTACT SURFACE BETWEEN WOOD 4 CONCRETE WALL SHALL HAVE SINGLE BOTTOM PLATE
AND DOUBLE TOP PLATE. END NAIL TOP PLATES 4 BOTTOM PLATES TO EACH STUD WITH W-16d NAIILS.
FACE NAIL DOUBLE TOP PLATES WITH (2)-16d NAILS AT EACH SPLICE, CORNER INTERSECTION, STAGGER
SPLICES A MINIMUM OF 48 INCHES. FACE NAIL BOTTOM PLATE TO (2)-16d NAILS.
ANCHOR BOLTS:
ANCHOR BOLTS TO BE A-301 OR BETTER ANCHOR BOLTS INTO CONCRETE SHALL BE 5/8'0 WITH
1 INCHES OF EMBEDMENT AND SPACED NOT MORE THAN 4' APART. THERE SHALL BE A MINIMUM
OF TWO BOLTS PER PIER WITH BOLT LOCATED NOT MOIL THAN 12 INCHES OR NOT LESS THAN
4 INCHES FROM EACH END OF EACH PIER A PROPERLY SIZED NUT WITH 3'x3'xli4' PLATE WASHER
SHALL BE TIGHTENED ON EACH ANCHOR BOLT TO THE P.T. 2x6 SILL PLATE.
ROOF TRUSS:
TRUSSES TO BE DESIGNED AND STAMPED BY REGISTERED PROFESSIONAL ENGINEER IN THE STATE
OF WASHINGTON. ROOF TRUSS DESIGN SHALL BE SUBMITTED FOR APPROVAL PRIOR TO FABRICATION.
TRUSSES SHALL BE REVIEWED BY THE BUILDING DEPARTMENT IF REQUIRED. NON -BEARING
WALLS SHALL BE HELD AWAY FROM THE TRUSS BOTTOM CHORD WITH AN APPROVED FASTENER
TO INSURE THAT THE TRUSS BOTTOM CHORD WILL NOT BEAR ON THE WALL. APPROVED HANGER
SHALL BE USED AT ALL CONNECTIONS OR RAFTER, JACK AND HIP TRUSSES TO THE MAIN GIRDER
TRUSS. ALL ROOF TRUSSES SHALL BE FRAMED AND TIED INTO THE FRAME WORK AND SUPPORTING
WALLS SO AS TO POW AN INTEGRAL PART OF WHOLE BUILDING. TRUSSES SHALL HAVE JOINTS WELL
FITTED AND SHALL HAVE ALL TENSION MEMBERS WELL TIGHTENED BEFORE ANY LOAD IS PLACED
UPON THE TRUSS. DIAGONAL AND BRACING SHALL BE USED TO BRACE ALL TRUSSES. TEMPORARY
SHORING AND BRACING OF TRUSSES DURING ERCTION IS THE RESPONSIBILITY OF THE CONTRACTOR
TRUSSES SHALL BE DESIGNED FOR A BOTTOM CHORD LIVE OF 10 PSF AND DEAD LOAD OF 1 PSF.
TOP AND BOTTOM CHORD LIVE LOAD DO NOT NEED TO BE DESIGNED FOR SIMULTANEOUSLY.
STRUCTURAL STEEL:
ANGLE, PLATES TO BE ASTM A36, Fy = 36 KSI.
WELD TO BE 3/16' MINIMUM CONTINUOUS FILLET, BY CERTIFIED WELDERS USING E10XX ELECTRODES.
ALL WELDS SHALL CONFORM TO THE LATEST EDITION OF AWS DI.I.
ALL STEELS EXPOSED TO WEATHER SHALL BE HOT DIP GALVANIZED. ALL STEEL NOT EXPOSED TO
WEATHER SHALL BE SHOP PRIMED.
SPECIAL CONDITIONS:
THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD. ALL DISCREPANCIES
SHALL BE REPORTED TO THE ARCHITECT OR ENGINEER THE CONTRACTOR SHALL PROVIDED
ADEQUATE SHORING AS REQUIRED UNTIL PERMANENT CONNECTIONS AND STIFFENING HAVE BEEN
INSTALLED. THE CONTRACTOR SHALL VERIFY SIZE AND ALL LOCATIONS OF ALL OPENINGS IN THE FLOOR,
ROOF, AND WALLS WITH ALL THE APPROPRIATE DRAWINGS. THE CONTRACTOR SHALL COORDINATE WITH
THE BUILDING DEPARTMENT FOR ALL BUILDING DEPARTMENT REQUIRED INSPECTIONS. DO NOT SCALE
THE DRAWINGS. THE DETAILS SHOWN ARE TYPICAL AND SHALL BE USED FOR LIKE OR SIMILAR CONDITIONS
NOT SHOWN.
SPECIAL INSPECTIONS:
PROVIDE SPECIAL INSPECTIONS IN ACCORDANCE WITH 'IBC 2015' FOR FOLLOWING:
REINFORCING, ANCHOR BOLT PLACEMENT
4 CONCRETE PLACEMENT
EXPANSION BOLTS 4 INSERTS
EPDXY ROUTED RODS 4 REBAR
PERIODIC 4 PRIOR TO ALL CONCRETE POUR
PERIODIC INCLUDING TORQUE TESTS
PERIODIC INCLUDING INSPECTION OF HOLE
CLEANLINESS 4 EMBEDMENT DEPTH PRIOR TO
ALL INSTALLATION
TYPICAL EXTERIOR WALL CONSTRUCTION:
(UNLESS OTHERWISE NOTED: SEE SHEAR WALL SCHEDULE)
I. SHEATHING: 15/32' APA RATED SHEATHING, EXTERIOR GLUE, EXTERIOR SIDE
OF WALL, ALL PANEL EDGES BLOCKED, NAILING:
Sd COMMON NAIL ® 6' O.G.: EDGES AND BOUNDARIES
Sd COMMON NAIL 9 12' O.C.: FIELD.
2. WALL PANELS ARE APPLIED WITH LONG DIMENSION ACROSS STUDS.
3. BOLTS AT 2x6 SILL PLATE TO CONCRETE WITH 5l/s'O A. BOLTS 9 48' O.C. (1' EMBED)
A. BOLTS TO BE PLACED 4' TO 12' FROM END OF EACH PLATE. ALL A. BOLTS SHALL
BE SECURED WITH 3'x3'x�/4' PLATE WASHER (SEE 10(o/53.1)
4. ALT. ATTACHMENT. 2x6 SILL PLATE W/ 'MASA' OR 'MASAP' 6 48' O.0 (SEE 101,102 4 103/53.1)
5. NAIL BOTTOM PLATE TO FRAMING BELOW WITH Ibd COMMON NAIL a 6' O.C.
6. FASTEN DOUBLE PLATE TO JOIST OR BLOCKING ABOVE WITH Ibd COMMON TOE NAIL a 6' O.C.
1. Sd COMMON: 0.131*21i2', 10d COMMON: 0.148*21i2' OR 0.148*31i4' (SEE SHEAR WALL SCHEDULE), Ibd COMMON: 0.16IW31i2'
SHEAR WALL SCHEDULE (12) (13)
MARK
APA RATED
SHEATHING
(1) (3) (10)
NAIL SIZE 4 SPACING
AT ALL PANEL EDGES
(3) (4)
STUD 4 BLOCKING SIZE AT
ADJOINING PANEL EDGES
(2) (5)
RIM JOIST OR BLK'G
CONN. TO TOP PLATE
(6) (1)
2x PLATE ATTACHMENT
SILL PLATE ATTACHMENT
SHEAR CAPACITY
PLF
NAILING TO
WOOD BELOW
A.B. TO CONC. BELOW
SILL PLATE AT FDN.
(8) (11) (14)
(9)
SEIS
WIND
W6
15/32' ONE SIDE
0.1484 x 211/2' a 6' O.C.
2x6
CLIP a IVO.C.
0.1484 x 31/4' ® 6' O.C.
5/0 A.B. a 48' O.C.
2x6
310
436
W4
15/32' ONE SIDE
0.148-0 x 21i2' a 4' O.C.
2x6
CLIP a IVO.C.
N/A
'MASA' 0 48' O.C.
2x6
460
645
NOTES:
I. PANELS ARE APPLIED WITH LONG DIMENSION ACROSS STUDS.
2. BLOCKING IS REQUIRED AT ALL PANEL EDGES.
3. PROVIDE SHEAR WALL SHEATHING AND NAILING FOR THE ENTIRE LENGTH OF THE WALLS INDICATED ON THE PLANS. ENDS OF FULL HEIGHT WALLS ARE DESIGNED
BY EXTERIOR OF THE BUILDING, CORRIDORS, WINDOWS, OR DOORWAYS OR AS DESIGNATED ON PLANS. SEE PLANS FOR HOLD-DOWN REQUIREMENTS.
4. SHEATHING EDGE NAILING REQUIRED AT ALL HOLDOWN POST. EDGE NAILING MAY ALSO BE REQUIRED TO EACH STUD USED IN BUILT-UP HOLDOWN POST. REFER TO
THE HOLDOWN DETAILS FOR ADDITIONAL INFORMATION.
5. INTERMEDIATE FRAMING TO BE WITH 2x6 MINIMUM MEMBERS. FIELD NAILING 12' O.C.
6. BASED ON 0.131'hx111/2' LONG NAILS USED TO ATTACH FRAMING CLIPS DIRECTLY TO FRAMING. USE 0.13141i2' NAILS WHERE INSTALLED OVER SHEATHING.
1. FRAMING CLIPS: A35 OR LTP4 OR APPROVED EQUIVALENT.
8. ANCHOR BOLTS SHALL BE PROVIDED WITH STEEL PLATE WASHER 1i4'x3'x3'. EMBED ANCHOR BOLTS 1' MINIMUM INTO THE CONCRETE.
9. PRESSURE TREATED MATERIAL CAN CAUSE EXCESSIVE CORROSION IN THE FASTENERS. PROVIDE NOT -DIPPED GALVANIZED (ELECTRO-PLATING IS NOT ACCEPTABLE)
NAILS AND CONNECTOR PLATES (FRAMING ANGLES, ETSJ FOR ALL CONNECTORS IN CONTACT WITH PRESSURE TREATED FRAMING MEMBERS.
10.1/16' APA RATED SHEATHING (055) MAY BE USED IN PLACE OF 15/32' SHEATHING PROVIDED THAT ALL STUDS ARE SPACED AT IV O.C.
11. CONTACT THE ENGINEER OF RECORD FOR ADHESIVE OR EXPANSION BOLT ALTERNATIVES TO CAST -IN -PLACE ANCHOR BOLTS. (SPECIAL INSPECTION WILL BE REQUIRED)
12. SHEAR WALL SCHEDULE BASED ON '2015 IBC' FOR DOUG-FIR LARCH FRAMING.
13. ALL SHEAR WALL TYPES MAY NOT BE USED ON PROJECT. COORDINATE WITH FRAMING PLANS.
14. USE SIMPSON 4/0 TITEN HD WITH STEEL PLATE WASHERS 1i4'x3'x3' EMBED 311/2' MINIMUM AT EXISTING CONC. STEM WALL. INSTEAD OF 5%'0 ANCHOR BOLTS.
REV1510N&
NO.
DATE
DESCRIPTIONS
0
0
0
0
0
D. S. Engineering
Consulting Structural Engineers
3121 147th Place SE
Mill Creek, WA 98012
T: 425-338-4776
03/20/2020
G IL S
'00 OF WASt ,�Orfi
28398
AL
�ssI0 A
L
Iz
II-�--Il �
C-IIJJ
II-�--IlII
�
III
H
U
LJJ
O
DATE: March 20, 2020
5GALE: 5€€ PLAN
JOE3 NO.: 20-010
DRAWN: ID. 5.
GNECK: ID. 5.
5�4EET TITLE
GENEfRAL
I ACT 5
SHEET
■
CJ
I
O
O
O
cM
0
LO
GA, .fin
O
O
co
O
O
N
IL 9 / S3.0, NOTE 4,
AG PIN PILES AND
NSPECTION
VIENTS
.JNDATION PLAN KEY
10.000
3'-6"
BATTER PILE
EXAMPLE
6" CONC. STEM WALL
SEE S3.0
12" X 16" CONC. GRADE
BEAM, SEE S3.0
0 4" DIA PILE
4" DIA PILE
BATTERED AT 100
DIRECTION INDICATED
OR EMBEDDED HOLD DOWNS, SHEAR WALL
AND 1ST FLOOR FRAMING
I N DAT I O N PLAN
4 8 16
a u I aieIIo, .s.
j achitecture + deign
7818
FARC17,1TECT
PAULAIELLO ,
STATE OF WASHINGTON
w
U
z
w
Q
I..I
V1
w
a
z
a
C
Q
CD
r
03.24.2020
Al: 06.05.2020 (correction 1)
FOUNDATION PLAN
PIN PILES
CJ
O
Im
0
Lo
I
►7
I
I
O-Al 011
O
O
Co
LATERAL DESIGN KEY
.,,,,,,,,,, SHEAR WALL TYPICAL W6,(U.N.0),
SEE S1.0. SHOWN FROM 1 ST FLR TO
2ND FLOOR / LOW ROOF.
MIN. LENGTHS INDICATED.
VERIFY DIMENSIONS IN FIELD.
OTHERWISE, TYPICAL EXTERIOR
WALLS TO HAVE PLYWOOD
SHEETING PER S1.0
HOLD DOWN LOCATIONS 1 ST FLR TO
y FOUNDATION SHOWN FOR
REFERENCE. COORDINATE W/
FOUNDATION. VERIFY IN FIELD
1 ST FLOOR
FRAMING PLAN
0 2 4 8 16
l/l/o/m, p a u I aieIIo, .s.
j architecture + deign
7818
REGISTERED
ARCfITECT
PAULAIELLO ,
STATE OF WASHINGTON
w
w
Q
V1
w
a
a �
O
a CD
r
Vow
03.24.2020
A------------
l:
--------------
------------
-------------
------------
1ST FLOOR FRAMING
PLAN
CJ
O
Im
0
LO
I
►7
I
I
L.` it l 011
O
O
co
LATERAL DESIGN KEY
.,,,,,,,,,, SHEAR WALL TYPICAL W6,(U.N.0),
SEE S1.0. SHOWN FROM 1 ST FLR TO
2ND FLOOR / LOW ROOF.
MIN. LENGTHS INDICATED.
VERIFY DIMENSIONS IN FIELD.
OTHERWISE, TYPICAL EXTERIOR
WALLS TO HAVE PLYWOOD
SHEETING PER S1.0
HOLD DOWN LOCATIONS 1 ST FLR TO
y FOUNDATION SHOWN FOR
REFERENCE. COORDINATE W/
FOUNDATION. VERIFY IN FIELD
2ND FLOOR &LOW
ROOF FRAMING PLAN
0 2 4 8 16
a u I aieIIo, .s.
j achitecture + deign
7818
REGISTERED
ARCfITECT
PAULAIELLO ,
STATE OF WASHINGTON
w
w
Q
V1
w
a
a �
O
a CD
r
Vow
03.24.2020 (Intake)
Al: 06.05.2020 (correction 1)
2nd FLOOR FRAMING
LOW ROOF FRAMING
GY-
J
rn
........................� ..r.. �....i.....D D ....
m p
O c
n
X
y
00
r
a
z
151-01'
M
0
on
CROUCH / MAUPIN RESIDENCE
1141 Viewland Way
Edmonds, WA 98020
301-011
30'-0"
15'-0"
v
co
co
m�
OD
„r D
y M
c/) m C? —
?r �
r
0O mm
0 �0
'a
DJ
(D
O
in
STOP RE INF. 1'
EA. SIDE OF JOINT
N
I' KEY 4' SLAB ON GRADE
CONT. W/ 6x6-W23xW2.9 W.W.F.
OR *3 a 18' O.G. EA. WAY
MESH RE INF.
OR 03 BAR (SEE PLAN)
CO 6TRUCTION JOINT
01
N.T.S.
NOTE:
SLAB JOINTS TO BE LOCATED BY THE CONTRACTOR W/
APPROVAL OF THE ARCHITECT. JOINTS TO BE LAID OUT IN
A RECTANGULAR PATTERN NOT MORE THAN 20 FEET IN ANY
DIRECTION W/ A MAXIMUM ENCLOSED AREA OF 400 SQ. FEET.
4' SLAB ON GRADE
~' ixs' JOINT W/ (ox6-W2.9xW2.9 W11F.
FILL W/ MASTIC OR *3 a IS' O.C. EA. WAY
e
57
--X---- X--- —----X__— — -- -
-)pon or 00 p0 00 0 0poo ---)oq 10 000 000
CONTROL JOINT
02 N.T.S.
KING STUD:
(2) ROWS OF 16d 3' OC
2 k (TOTAL 12 EA. SIDE)
STUD
MIN 8' REQ'D FOR NEXT
TOP OR BOTTOM R SPLICE
5FL ICE
O5 N.T.S.
STUDS
OPENING
ONE
UP TO 5'
UP TO S' 4
TWO
GARAGE
DOOR
16d a 12' O.G. -
BETWEEN STUD
(TYP)
— STUD
(4)-16d
TO HEADER
(TYP)
(2)-16d TOE NAIL
e EA. END (TYP)
-HEADER
(SEE PLAN)
USE (1)-CRIPPLE
(TYP)
BEAM PERP. TO WALL:
4x : (2) CRIPPLES MIN. UNDER BEAM
6x : (3) CRIPPLES MIN. UNDER BEAM
m$ HEADER
11-011 11,
(MIN) (SEE 1ARCH)
— °d
d ° d '
d ° *4 NOSING 46
11=1I 1111
4' SLAB ON GRADE �° ° °
W/ 6x6-W23xW2.9 W.W.F. d
OR *3 a 18' O.C. EA. WAY 4 ° d GONG. SLAB OR
(95% COMPACTION (V ° ° FINISH GRADE
REQ'D UNDER) *4 e 16' O.C. ° a
*4 a EA. RISER ti
.� d°
(0-*4 --\ II I II I IIIE,I I I=I 1I -1
� �CONC. 57,41R
w � N.T.S.
DOUBLE STUDS
e 'MST37' W/
EDGE NAIL
4
3/4' PLYWD. SHT'G
m DOUBLE STUDS —
e 'ST6224' W/
EDGE NAIL
SIMPSON 3/4' PLYWD. SHT'G
RIM BOARD
'
STRAP
(SEE PLAN)
RIM BOARD
JOIST (SEE PLAN
\
FOR DIRECTION)
,
A
4
/ \
CU
WOOD BEAM (BENT
LU
STRAP a BEAM)
___
° d
DOUBLE STUDS
° d
e STRAP W/
d °
EDGE NAIL
1/2' PLYWD. SHT'G
a
13
�t q4A
1
°
� I I
rn J
I Ir
6'
PILE I.D. 2' TO (o'
(2)-*5 TOP 4 BOTTOM
W/ (6)-*3T (4' O.C.)
FROM 4'0 PIN PILE
E 10"O.C. IN BETWEEN
(SEE 04/53.0)
(2)-Sx2'-6' (3' GA.)
11/2' ABOVE FROM
fE 5/s'x6'x6' (TYP)
6 2 EA. SIDE (MIN)
4'0 PIN PILES:
GALVANIZED SCHOULE-40,
ASTM A-53 GRADE 'A' PIPE
W/ R 51s'x6'x6' AT TOP
NEW STEEL PIPE SECTION
00 11/4" TO 2' WIDE X- STRONG RING
O 1/4 FILET WELDED TO PIPE SLEEVE
DRIVEN STEEL PIPE SECTION
BEVELED END TO AID INSERTION
COMPRESSION FITTED SLEEVE COUPLER
30" MIN. LAP (TYP)
ALT. BENDS
° d
° ■■. .mm.■m■.. w....
° d a
° ° d
*4 a 14' O.C. ° d °
EACH WAY •
EL�W BAR
SAME SIZE < SPACING
AS HORIZ. BAR
d
a
PLAN
°
CONC. WALL
11/2' PLYWD. SHT'G
DOUBLE STUDS -
e 'DTTIZ' W/
EDGE NAIL
— SIMPSON
'ST6224'
STRAP
(SEE PLAN)
'DTTIZ'
11/2' PLYWD. SHT'G
.' 3/4' PLYWD. SHT'G
TJI (SEE PLAN)
STEEL PIPE PILE (PIN PILE) NOTES:
I. SEE ARCHITECT DRAWINGS FOR DIMENSION.
2. FINAL 44 STEEL PILES AND GRADE BEAMS SHALL BE SUBMITTED TO ENGINEER FOR APPROVAL
PRIOR TO CONSTRUCT BY G.C.
• : INDICATES 44 PIN PILE
INDICATES BATTERED(I14:6V) 44 PIN PILE AND DIRECTION.
3.4't STEEL PILES (SCHEDULE 40) SHALL BE HOT DIP GALVANIZED AND TESTED IN ACCORDANCE
WITH ASTM STANDARD D 1143-81 AND AT LEAST 3% PIN PILES SHOULD BE LOAD TESTED.
4. GEOTECHNICAL SPECIAL INSPECTOR SHALL BE CONTINUOUSLY PRESENT DURING THE PIN
PILE INSTALLATION.
5.44 PIN PILES SHALL BE DRIVEN TO REFUSAL WITH A MINIMUM 650 lb. HYDRAULIC HAMMER
THE DRIVING CRITERIA WILL BE DETERMINED BASED ON THE ACTUAL HAMMER SIZE
SELECTED BY THE CONTRACTOR THE TYPICAL HAMMER WEIGHTS VS. MINIMUM PILE
PENETRATION RATES AT REFUSAL ARE SHOWN BELOW.
650-lbs HAMMER (20 SECONDS PER I INCH OF PILE PENETRATION)
6. PIN PILES SHALL BE DRIVEN IN NOMINAL SECTIONS AND CONNECTED WITH COMPRESSION
FITTED SLEEVE COUPLERS (WELDING OF PIPE JOINTS IS NOT RECOMMENDED).
1. SEE THE RECOMMENDATION FROM GOETECHNICAL REPORT FROM Associated Earth Sciences, Inc.
REPORT NO.20190294E001 (January 10, 2020)
C,RADE BEAM a PILE
N.T.S.
6x6 POST
W/ 'PB66'
36" MIN. LAP (TYP)
t OF 44 PIN PILE
I, 4' 4' 4' 4' 4' 4'
!001NMI
0I
t OF 4'0 PIN PILE
10"L �'F �'F11 °F �'F �'F 4
11
d ° °
■ °
d - w
° ° X w d
V ° d ° d
d
(4)-05 W/ (6)-*3T e 4' O.C.
ABOVE 44 PIN PILE d
d 11 d ° 10' O.C. IN BETWEEN
d ° d
d ELBOW BAR:
MATCH W/ (4)-05
d d REBAR *BEAM
(SEE 9/5I.1)
12'X16'
GRADE BEAM
I to
_R w
d N (l
°
° LL
v
d ° (4)-05 W/ (6)-*3T 4' O.G.
ABOVE 44 PIN PILE 4
d ° ° d ° 10' O.C. IN BETWEEN
d d
d
a
FLAN AN ° d dELBOW BAR:
° d
a 3'-0-
d Cn
CORNER REIM=.
U N..s
12 "xl6"
GRADE BEAM
'HDU2' OR 'HDU5'
(2)-2x6 DF*2 HOLD-DOWN (2)-2x(o 1) 'HDU2'
W/ EDGE NAIL (SEE PLAN) W/ EDGE NAIL
I, HOLD-DOWN
(SEE PLAN)
u
d d
8 ° SEE TABLE d d °
d
° ° a FOR ANCHOR ° d
d
d e n
°s
d
6' GONG. WALL 6' GONG. WALL
(SEE PLAN) (SEE PLAN)
HOLD-DOWN 5CHEDULE
MARK
HOLD-DOWN
HOLD-DOWN
CHORD
HOLD-DOWN CHORD
FASTENER
ANCHOR
DIA.
ANCHOR
EMBED. (Le)
ALLOWABLE
TENSION LOAD
HDU2
HDU2-SDS25
(2)-2x6
((0)-SDS 1i4'x2i2'
SST516
12
2550 LB.
HDU5
HDU5-SDS25
(2)-2x6
(14)-SDS 1i4'x2i2'
654%44
IS'
5645 LB.
NOTE:
HOLD-DOWN TO BE MANUFACTURED BY SIMPSON STRONG -TIE OR ENGINEER APPROVED EQUAL.
REFER TO THE LATEST EDITION OF MFR. CATALOG FOR ADDITIONL REQUIREMENTS.
0� I-EOLp DOWN I" I'-m"
6x6 POST W/
'CPT66Z'
(SITS ON TOP OF
6' GONG. WALL)
d ° id °
d 2x(o SILL 1E
d--- - °
10'AV PLITH W/ ° ' �r
(4)-*4 VERT. ° ° °
d ° ((0 INTO GRADE BEAM)
W/ *3 TIES * 4: O.C. a' ° °
d °
- d °
° 12'xl6' GRADE BEAM 6' CONC. WALL
. ° • (SEE PLAN)
-4T rF I CAL.
4' SLAB ON GRADE
W/ 6x6-W23xW23 W.W.F.
OR *3 a 18' O.G. EA. WAY
4'4, (SCHEDULE 40)
PIN PILE (SEE PLAN)
(0 x(o F 06 T
10 SCALE: 1"=1'-0"
(2)-2x6 DF*2 -
W/ EDGE NAIL
2x6 e -
16' O.G.
'HDU2'
HOLD-DOWN
(SEE PLAN)
2x6 (4' O.C.)
'CNWSis'
12'xl6' GRADE BEAM
(SEE PLAN)
SEE TABLE
FOR ANCHOR
6x6 POST
W/ 'PB66'
4' SLAB ON GRADE
W/ 6x6-W2.94J23 W.W.F.
OR *3 a 18' O.G. EA. WAY
° id°
° d
d °
d
° (2)-Sx1'-4' (3' GA.)
d
° d 11/2' ABOVE FROM
° M 5is'x6'x6' (TYP)
d
d
_ (k
20'x2O'xl6' PILE CAP
`Y' U
W/ (4)-05 EA. WAY
I
I (TOP E BOTTOM)
I
I
44 (SCHEDULE 40)
PIN PILE (SEE PLAN)
REVISIONS:
NO.
PATE
DE5CRIPTION5
01
7/21/2020
DSD Correction
0
0
D. S. Engineering
Consulting Structural Engineers
3121 147th Place SE
Mill Creek, WA 98012
T: 425-338-4776
03/20/2020
S$
ILWA
28398
cRAL B��l
NAL
I
I
� JJ
rI�I^I�7al�ll
I
II �
4
U
W
0
DATE: March 20, 2020
SCALE: 5EE PLAN
JOB NO.: 20-010
DRAWN:
5NEET TITLE
T%*T"'F I CAL
DTAIL=5
1$ 5E CT I ON5
5HEET
■
loci Is 6' O.G.
PLYWD. SHT'G
2x6 SILL fE W/ 'MASA' 8 46' O.C.
'LSTAI2' ,9 48' O.C.
EDGE NAIL
(BETWEEN SILL lE E TJI)
FINISH GRADE
d
(2)-Sd
OR SLAB ON ;
(2)_"4,
°
PER JOIST
GRADE tv
GARAGE
°
d
°
:
6' GONG. WALL W/
"4 o 14' O.G. EA. WAY
(VERT BAR 6 It OF WALL)
°
2x4 9 16' O.G.
PROPER WATER
d
.
2x4 SILL lE
PROOFING BY G.C.
W/ 'PHNW-12'
Q 16' O.C.
d
d
Il�i�ll�—III
�
III
`
12'xl6' GRADE BEAM
W/ 4'-P PIN PILE
° g
(SEE 53.0)
6ECTION
101
SCALE: 1"
= 1'-0"
PLYWD. SHT'G -I
EDGE NAIL
d
(2)-M4
—III—III— d
loci a 6' O.C.
2x6 SILL fE W/ 'MASA' a 48' O.C.
- 'LSTAI2' a 48' O.C.
(BETWEEN SILL fE 4 TJI BLK'G)
(2)-8d III
PER BLK'G� (2)-10d TOE
\ III NAIL (TYP)
° L TJI BLK'G
6' CONC. WALL W/ 48' O.C.
04 e 14' O.G. EA. WAY 0
(VERT BAR 9 � OF WALL) ,
2x4 ,9 24' O.G.
PROPER WATER d °
PROOFING BY G.G. 2x4 SILL E
° ° W/ 'PHNW-12'
� 16' O.C.
°III-11
° d °
12'x16' GRADE BEAM
W/ 44 PIN PILE
(SEE 53.0)
6ECTION
102 SCALE: 1" = 1'-0"-
lod m 6' O.C.
2x6 g
24' O.G.
2x6 6 IV O.G.
(2)-10ci TO EA.
loci 9 foO.G. PLYWD. SHT'G
STUD d loci � TRUSS
6' O.C. IN BTWN. (GARAGE)
(I)-10d TO EA.
STUD
PLYWD. SHT'G
10d a (o' O.G.
>- EDGE NAIL EDGE
'A35' 16' O.C. NAIL
RIM BOARD
111/9 TJI 110 a W/ (2)-10d TO
g 16' O.C. P.T. 2x6 SILL fE EACH TJI 'A35'
W/ 'U210' ° j d W/ 5/9'0 A. BOLT I6' O.C.
l2)-"4 _ (7' EMBED) 4 EDGE NAIL
SEE 102/53.1 IEI/4x3x3 ,9 32' O.C. � .
FOR BELOW PLYWD. SHT'G TJI JOIST
(AT GARAGE) (SEE PLAN)
j� 6 g W/ TYP. EXTERIOR (2)-Sd PER JOIST
SEC I* ION � NAILING (ONE a EA. SIDE)
I 2x16' O.C.
201 SCALE: 1II 1 = -�II
6ECTIOil
2�2 SCALE: 1" = 1'-0"
PLYWD. SHT'G -
lod 0 6' O.G.
WOOD TRUSS
(SEE PLAN)
EDGE
NAIL
RIM BOARD -
W/ (2)-10d TO
EACH TJI
EDGE NAIL—
PLYWD. SHT'G —
W/ EXTERIOR
NAILING
2x6 6
24' O.C.
(1)-'A35' PER
BLK'G
2x6 Q
24' O.C.
loci Q 6' O.C.
TJI JOIST
(SI=1= PLAN)
(2)-Sd PER JOIST
(ONE a EA. SIDE)
2x6 a 16' O.G.
&ECTION
2�� SCALE: 1" = 1'-0"
PLYWD. SHT'G - 2x6 G
loci a 6' O.G. 24' O.C.
(I)-'A35' PER
EDGE NAIL BLK'G
2x6 a
24' O.G.
WOOD TRUSS
(SEE PLAN) loci 6 O.C.
2x8 BLK'G
W/ l2)-loci
lod a 10' O.G. (3' O.G.)
(STAGG) 8' O.G.
WOOD BEAM TJI JOIST
(SEE PLAN) (SEE PLAN)
W/ 'IUS'
5ECTION
2�8 SCALE: 1" = 1'-0"
PLYWD. SHT'G -
EDGE NAIL
(2)-"4 J °
d
loci * 4' O.G.
- 2x6 SILL IE W/ 'MASA' m 16' O.C.
'LSTA12' m 46' O.C.
(BETWEEN SILL IE E TJI BLK'G)
III
PER BLK'G� (2 )' loci TOE
\ III NAIL (TYP)
d ° TJI BLK'G
6' GONG. WALL W/ a 48' O.C.
04 * 14' O.G. EA. WAY
(VERT BAR a It, OF WALL)
2x4 ,9 24' O.G.
PROPER WATER ° °
2x4 SILL fE
PROOFING BY G.G.
° ° W/ 'PHNW-72'
16' O.C.
d
� °
12'xl6' GRADE BEAM
W/ 4'-P PIN PILE
(SEE 53.0)
6ECTION
103 SCALE: 1" = 1'-0"-
PLYWD. SHT'G
EDGE NAIL
BE
(SEE PLAN)
ISEE PLAN)
W/ 'IUS' OR 'ITS'
SE CT I CN
2�3 SCALE: 1" = 1'-f�"
loci m 6' O.C.
'H3' PER RAFTER (I)-'A35' PER
(NOT SHOWN) BLK'G
EDGE NAIL
2x6 RAFTER J
Q 24' O.C.
(SEE PLAN) ---
�� i WOOD TRUSS
PLYWD. SHT'G `� i 24' O.G.
u
GLIB HEADER
(SEE PLAN) j
2x6 Q 24' O.C.
5ECTION
2�9 SCALE: 1" = 1'-0"
loci Is 6' O.G.
PLYWD. SHT'G
W/ 'W6' NAILING 2x6 6 16' O.G.
(10' MIN. SEE PLAN)
loci Is 6' O.G.
EDGE NAIL -\
'A35' a
16' O.G.
EDGE NAIL,
L TJI ISEE PLAN)
PLYWD. SHT'G
(2)-5d PER TJI
W/ 'W6' NAILING
(ONE 6 EA. SIDE)
(10' MIN. SEE PLAN)
2x6 9 16' O.C.
EDGE NAIL
P.T. 2x6 SILL fE
W/ 5/b', A. BOLT
(7' EMBED) E
d °
fE'/4x3x3 ,s 48' O.C.
° , d
°
I I III—
;;
_
�-I I I I
°
d U
° °
12'xl6' GRADE BEAM
°
W/ 4'0 PIN PILE
° h s
(SEE 53.0)
WOOD TRUSS
6 24' O.G.
(SEE PLAN)
BEAM -
(SEE PLAN)
5ECTION
104 SCALE: 1" = 1'-0"
L2x6QIVO.C.
_ (SEE PLAN)
2x6 m 24' O.C.
lod a 6' O.G.
LOFT
2x8 Q IV O.C.
(SEE PLAN)
W/ 'LUS26'
6ECTION
2�� SCALE: 1" = 1'-,a"
lod a 6' O.G.
'H3' PER RAFTER
(NOT SHOWN)
EDGE NAIL
PLYWD. SHT'G
- 2x6 RAFTER
9 24' O.G.
W/ 'LUS24'
2x6 Q 24'O.C.
WOOD TRUSS
(SEE PLAN)
6ECTION
21� SCALE: 1" = 1'-0"
L TJI (SEE PLAN)
(2)-8d PER TJI
(ONE 0 EA. SIDE)
2x6 9 IV O.G.
P.T. 2x6 SILL R
W/ 5/9'0 A. BOLT
(7' EMBED) E
d fE'/4x3x3 ,0 48' O.C.
I1=1I1 b; =1I1=1
° 12'xl6' GRADE BEAM
W/ 4'0 PIN PILE
s 8 (SEE 53.0)
6ECTION
105 SCALE: 1" = 1'-0"
loci Q 6' O.C.
P.T. 2x6 SILL fE
W/ 5/g4t, A. BOLT
PLYWD. SHT'G -
(7' EMBED) d
EDGE NAIL
R'03x3 s9 48"O.C.
4' SLAB ON GRADE
°
W/ ox6-W2.9xW2.9 W.WF.
OR *3 18' O.G. EA. WAY
(2)-"4
°
°
°
° d
PROPER WATER
°
�d°
a�
—I
-°
1(—
PROOFING BY G.G.
d
6' GONG. WALL W/
d
°
04 m 14' O.C. EA. WAY
d
(VERT BAR 9 It OF WALL)
°
°
d
12'xl6' GRADE BEAM
W/ 4'�O PIN PILE
°
(SEE 53.0)
° 4 8
4' SLAB ON GRADE
(1)-04 NOSING
W/ 6x6-W2.9xW2.9 W.W.F.
(AT GARAGE DOOR)
OR 03 6 18' O.G. EA. WAY
6ECTION
10ro SCALE: 1" = 1'-0"
2x6 m 24'O.C.
:-
PLYWD. SHT'G
EDGE NAIL
lod g 61O.C.
EDGE NAIL
RIM BOARD
W/ (2)-10d TO
lod 6' O.G.
EA. BLK'G
WOOD TRUSS _-
--
'LTP4' g 16' OC
'A35' m
_
(SEE PLAN)
(PLYWD JOINT G RIM
. 32' OC.
TJI
2x6 W/ (2)-16d = =
- -
CONTRACTOR'SLL
- (SEE PLAN)
OPTION)
TO EACH STUD
TJI BLK'G � 32' O.G.
EDGE NAIL
W/ lod a 4' O.C.
=�
2x6 6 24' O.G.
PLYWD. SHT'G
(2)-8d PER BLK'G
loci 6' O.C.
(ONE Q EA. SIDE)
2x8 LEDGER W/
2x6aIVO.C.
2x8 LEDGER
W/ (3)-16d TO
(2)-'SDWS22600D5
EACH STUD WOOD TRUSS
2x6 LEDGER (GRID OD )
EACH STUD
(SEE PLAN)
W/ (2)-16d TO EA. STUD
W/ 'LUS26'
SECTION
6ECTION
2��
2��o
SCALE: 1" = 1'-,a"
SCALE: 1"
= 1'-�"
'H3' PER TRUSS
(NOT SHOWN)
loci 9 (I)-'A35' PER
(01 O.G.
10d a (I)-'A35' PER
(01 O.C.
'143' PER TRUSS
BLK'G
BLK'G
(NOT SHOWN)
EDGE NAIL EDGE NAIL
WOOD TRUSS
--- WOOD TRUSS
PLYWD. SHT'G ----� (SEE PLAN)
` (SEE PLAN)
w� PLYWD. SHT'G
- w�
A
A
HEADER (SEE PLAN)
2x6 6 24' O.C.
5ECTION
211 SCALE: 1" = 1'-0"
REVISIONS:
NO.
DATE
DE5CRIPTION5
0
0
0
D. S. Engineering
Consulting Structural Engineers
3121 147th Place SE
Mill Creek, WA 98012
T-. 425-338-4776
03/20/2020
O�G IL 8
GY WA
28398
c�RAL
�SSIDNAL
E��l
II I�
II ID
�11
II �
mz
LU
H
CU
w
O
DATE: March 20, 2020
5CA1=E: 5EE PLAN
JOB NO.: 20-010
DRAWN: D.5,
GOECK: D.5.
SHEET TITLE
5E CT I ONS
DETAILS
SHEET
■