Loading...
Struct Corrections 6.11.20CORRECTIONS Maupin-Crouch Residence 1141 Viewland Way Edmonds, WA 98020 PLAN CHECK: BLD2020-0349 DATE: May 29, 2020 D. S. Engineering Consulting Structural Engineers 3121 147th Place SE Mill Creek, WA 98012 T: 425-338-4776 05/29/2020 G IL L OF ED City of Edmonds ul PLAN REVIEW COMMENTS BUILDING DIVISION �sr. t89° (425) 771-0220 DATE: 5/20/2020 TO: Applicant: PAUL AIELLO ARCHITECTS Owner: CROUCH PETER D & MAUPIN TERRI K FROM: KEVIN BLOOMFIELD RE: Plan Check: BLD2020-0349 Project Address: 1141 VIEWLAND WAY Project: CROUCH/MAUPIN- NEW SFR, P&M INCL During a review of the plans by the Building Division for compliance with the applicable building codes, it was found that the following information, clarifications, or changes are needed. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments that require attention beyond the scope of this letter. Items that recur on this list appear in italics. General: 1. Plans do not show a whole house ventilation system. Provide calculations and type of system �Y� (intermittent or continuous) include CFM in calculations. (- Z. �( Special inspection will be required for installation of Piles. 3. Plans do not show r of ventilation.. S� lcnlat.0 s and required ventilation on plans. Sheet A 2.1: 4. Make up air is required in the laundry room the combination of exhaust fan and dryer fan requires make up air in this location. This will help in the operation of the dryer to assure it is operating as it should. 5. If kitchen hood exceeds 400 cfm makeup air will be required in this location also. M1503.4 Makeup Air Required 7. Exhaust hood systems capable of exhausting in excess of 400 cubic feet per minute (0.19 m3/s) shall be mechanically or naturally provided with makeup air at a rate approximately equal to the exhaust air rate. Page 1 of 1 8. Mechanical protection for Water heater and Sink in Garage is required. In addition to the platform stated on the plans and Bollard or other protection against mechanical damage will be required. 502.1.1 Elevation and Protection' Elevation of water heater ignition sources and mechanical damage protection requirements for water heaters shall be in accordance with the International Mechanical Code and the International Fuel Gas Code. Sheet S 3.0: (9. emt stairs show reinforcement steel on the slanted bottom. This will require 3" of cenoverage in this area. R403.1.3.5.3 Support and Cover Reinforcement shall be secured in the proper location in the forms with tie wire or other bar support system to prevent displacement during the concrete placement operation. Steel reinforcement in concrete cast against the earth shall have a minimum cover of 3 inches (75 mm). Calculations Packet: Note: Beams in calculations should reflect beams expected to be used in the construction. Any beams not used should be removed from the calculations to eliminate confusion during the building process. 10. 1pecific beam names and designation should be unique to each beam regardless of the floor they are located on. This eliminates confusion on every level from review to construction. For example there 1is two number 1gs�and 2's. Rgnumbe(rraallll beams with a unique designation.OA4M�(D4CJ To�$ `C� N10 T 11.ream doe mat w t r �fl"te lans. ange"�to the t arn: e2 11W pwz- 12. eam designated in calculations as ( )2 11 7/8 TJI 110 and'210, are not reflected on the plans. Add these beams to plans in the designated locati ns. su �I "1413. eam 8 Reflects (_) 2x4 and (� .It appeaconfiguration either does not satisfy �1 1 ca cu ations or is very close. Verify which is being install d. y • � = ghnss f ��0 50 Thank you for the thorou ness of these plans and ca culation . owev r, all t e handwritten notes makes it confusing and hard to decipher. If'possible and as appropriate, please remove any unnecessary writing and notes form the plans and calculations. For example using a note to show Dead, Live and Snow load is only necessary one time. Page 2 of 3 ITEM -4�q (MIN) V d •° a �— ° a 4' SLAB ON GRADE II' ARCM 04 NOSING -f7 �- ° bxb-W2.9xW2.9 WWF. OR 03 5 IS' OL. EA. WAY °. CONC. SLAB OR a (S5% COMPACTION Uv FINISH GRADE MOD UNDER) •4 a Ib' OL. a a •4 a EA. RISER �'\ Ga .. (D-04 tow z � 6' ��CONC. STAIR w� N.T.S. Q I I I I I I I I i I - -I I II f I ' I I I I I I I I I I I I O i G lv-w I z► r.8. I I i O � Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb + 2400 psi E : Modulus of Elasticity Load Combination iBC 2015 Fb - 1850 psi Ebend- xx 1800ksi Fc - Pdl 1650 psi Eminbend - xx 950ksi Wood Species : DF/DF Fc - Perp 650 psi Ebend- yy 1600ksi Wood Grade : 24F - V4 Fv 265 psi Eminbend - yy 850ksi Beam Bracing : Beam is Fully Braced against lateral -torsional buckling Ft 1100 psi Density 31.21 pcf a D(0.165) S(0 275) Uniform Load: D = 0.1650, S = 0.2750 , Tributary Width =1.0 ft aximum Bending Stress Ratio = Section used for this span fb : Actual FB : Allowable Load Combination Location of maximum on span = Span # where maximum occurs = Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection Load Combination Segment Length +D+H Length =10.0 ft +D+L+H Length =10.0 ft +D+Lr+H Length =10.0 ft +D+S+H Length =10.0 ft +D+0.750Lr+0.750L+H Length =10.0 ft +0+0.750L+0.750S+H Length =10.0 ft Span = 10.0 ft rvice loads entered. Load Factors will be applied for calculations. 0.4641 Maxim Shear Stress Ratio = 0.230 :1 5.5x7.5 Se ion used for this span 5.5x7.5 1,280.00psi fv : Actual = 70.07 psi 2,760.00psi Fv : Allowable = 304.75 psi Load Combination +D+S+H 5.000ft ocation of maximum on span = 0.000 ft Span # 1 n # where maximum occurs - Span # 1 0.179 in Ratio = 0.000 in Ratio 671 >=24 S. 0<240 0.286 in Ratio = 419>=180 _ / 0.000 in Ratio = 0 <180 Max Stress Ratios IW Values Span# M V Cd CFN Ci Cr Cm C t CL M Shear 0.00 0.00 0.00 0.00 1 0.222 0.110 0.90 1.000 1.00 1.00 1.00 1.00 1.00 2.06 480.00 2160.00 0.72 26.28 238.50 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 1 0.200 0.099 1.00 1.000 1.00 1.00 1.00 1.00 1.00 2.06 480.00 2400.00 0.72 26.28 265.00 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 1 0.160 0.079 1.25 1.000 1.00 1.00 1.00 1.00 1.00 2.06 480.00 3000.00 0.72 26.28 331.25 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 1 0.464 0.230 1.15 1.000 1.00 1.00 1.00 1.00 1.00 5.50 1,280.00 2760.00 1.93 70.07 304.75 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 1 0.160 0.079 1.25 1.000 1.00 1.00 1.00 1.00 1.00 2.06 480.00 3000.00 0.72 26.28 331.25 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 1 0.391 0.194 1.15 1.000 1.00 1.00 1.00 1.00 1.00 4.64 1,080.00 2760.00 1.63 59.12 304.75 �0 Description : GLB Load Combination Max-Wess Ratios Moment Values Shear Values Segment Length Span # M V C d C FN C i Cr C m C t C L M fb F'b +D+0.60W+H 11000 1.00 1.00 1.00 1.00 1,00 0.00 V 0.00 fv 0.00 Fv 0.00 Length = 10.0 ft 1 0.125 0.062 1.60 1.000 1.00 1.00 1.00 1.00 1.00 2.06 480.00 3840.00 0.72 26.28 424,00 +0+0.70E+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length =10.0 ft 1 0.125 0.062 1.60 1.000 1.00 1.00 1.00 1,00 1.00 2.06 480.00 3840.00 0.72 26.28 424.00 +D+0.750Lr+0.750L+0.450W+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 10.0 ft 1 0.125 0.062 1.60 1.000 1.00 1.00 1.00 1.00 1.00 2.06 480.00 3840,00 0.72 26.28 424.00 +0+0.750L+0.750S+0.450W+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 10.0 ft 1 0.281 0.139 1.60 1.000 1.00 1.00 1.00 1.00 1.00 4.64 1,080.00 3840.00 1.63 59.12 424.00 +D+0.750L+0.750S+0.5250E+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length =10.0 ft 1 0.281 0,139 1.60 1.000 1.00 1.00 1.00 1.00 1.00 4.64 1,080.00 3840,00 1.63 59.12 424.00 +0.60D+0.60W+0.60H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 10.0 ft 1 0.075 0.037 1.60 1.000 1.00 1.00 1.00 1.00 1.00 1.24 288.00 3840.00 0.43 15.77 424.00 +0.60D+0.70E+0.60H 1,000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length =10.0 ft 1 0.075 0.037 1.60 1.000 1.00 1.00 1.00 1.00 1,00 1.24 288.00 3840.00 0.43 15.77 424.00 Load GomCN19 m Span Max. " " Defl Location in Span Load Combination Max. "+" Defl Location in Span +04" 1 0.2861 5.036 0.0000 0.000 Support notation : Far left is #1 Values in KIPS Load ConUrwdon Support 1 Support 2 Overall MAXimum 2.200 2.200 Overall MINimum 1.375 1.375 +D+H 0.825 0.825 +D+L+H 0.825 0.825 +D+Lr+H 0.825 0.825 +D+S+H 2.200 2.200 +D+0.7501-r+0.7501-+H 0.825 0.825 +D+0.750L+0.750S+H 1.856 1.856 +D+0.60W+H 0.825 0.825 +D+0.70E+H 0.825 0.825 +D+0.7501-r+0.750L+0.450W+H 0.825 0.825 +D+0.750L+0.750S+0.450W+H 1.856 1.856 +D+0.750L+0.750S+0.5250E+H 1.856 1,856 +0.60D+0.60W+0.60H 0.495 0.495 +0.60D+0.70E+0.60H 0.495 0.495 D Only 0.825 0.825 Lr Only L Only S Only 1.375 1.375 W Only E Only H Only Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb + 850 psi E: Modulus of Elasticity Load Combination i BC 2015 Fb - 850 psi Ebend- xx 1300 ksi Fc - Pdl 1300 psi Eminbend - xx 470ksi Wood Species ; Hem Fir Fc - Perp 405 psi Wood Grade : NO-2 Fv 150 psi Beam Bracing : Beam is Fully Braced against lateral -torsional buckling Ft 525 psi Density 26.84pcf D(0 045) S(0 075) ����j` �� ,Span = 3.50 ft Service loads entered. Load Factors will be applied for calculations Uniform Load: D = 0.0450, S = 0. 750 , Tributary Width =1.0 Maximum Bending Stress Ratio = 0.24fi 1 M imum Shear Stress Ratio = 0.146 : 1 Section used for this span 2-2x4 Section used for this span 2-2x4 fb : Actual 360.00psi fv : Actual = 25.18 psi i FIB: Allowable = 1,466.25psi Fv: Allowable = 172.50 psi j Load Combination Load Combination +D+S+H Location of maximum on span = 1.750ft Location of maximum on span 3.219ft i Span # where maximum occurs = Span # 1 an # where maximum = Span # 1 j Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection 0.018 in 0.000 in Ratio = Ratio = 2297>=3 0 <360 4 Max Downward Total Deflection 0.029 in Ratio = 1436>=240 Max Upward Total Deflection 0.000 in Ratio = 0 <240 C✓ l�� 1 �� i Load Combination Max Stress Ratios Mome Shear Values Segment Length Span # M V C d C FN C i Cr C m C t C L M fb Pb V fv Fv +D+H 0.00 0.00 0.00 0.00 Length = 3.50 ft 1 0.118 0.070 0.90 1.500 1.00 1.00 1.00 1.00 1.00 0.07 135.00 1147.50 0.07 9.44 135.00 +D+L+H 1.500 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 3.50 ft 1 0.106 0.063 1.00 1.500 1.00 1.00 1.00 1.00 1.00 0.07 135.00 1275.00 0.07 9.44 150.00 +D+Lr+H 1.500 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 3.50 ft 1 0.085 0.050 1.25 1.500 1.00 1.00 1.00 1.00 1.00 0.07 135.00 1593.75 0.07 9.44 187.50 +D+S+H 1.500 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 3.50 ft 1 0.246 0.146 1.15 1.500 1.00 1.00 1.00 1.00 1.00 0.18 360.00 1466.25 0.18 25.18 172.50 +D+0.750Lr+0.75OL-+H 1.500 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 3.50 It 1 0.085 0.050 1.25 1.500 1.00 1.00 1.00 1.00 1.00 0.07 135.00 1593.75 0.07 9.44 187.50 +D+0.750L+0.750S+H 1.500 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 3.50 it 1 0.207 0.123 1.15 1.500 1.00 1.00 1.00 1.00 1.00 0.16 303.75 1466.25 0.15 21.25 172.50 i -rO4 J* 10 Description Load Combination eRatios Moment Values Shear Values Segment Length Span # M V C d C FN C i Cr Cm C t C L M ib F'b V fv F'v +D+0.60W+H 1.500 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 3.50 ft 1 0.066 0.039 1.60 1.500 1.00 1.00 1.00 1.00 1.00 0.07 135.00 2040.00 0.07 9.44 240.00 +D+0.70E4H 1.500 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 3.50 ft 1 0.066 0.039 1.60 1.500 1.00 1.00 1.00 1.00 1.00 0.07 135.00 2040.00 0.07 9.44 240.00 +D+0.750Lr+0.750L+0.450W+H 1.500 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 3.50 ft 1 0.066 0.039 1.60 1.500 1.00 1.00 1.00 1.00 1.00 0.07 135.00 2040.00 0.07 9.44 240.00 +D+0.750L+0.750S+0.450W+H 1.500 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 3.50 ft 1 0.149 0.089 1.60 1.500 1.00 1.00 1.00 1.00 1.00 0.16 303.75 2040.00 0.15 21.25 240.00 +D+0.750L+0.750S+0.5250E+H 1.500 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 3.50 ft 1 0.149 0.089 1.60 1.500 1.00 1.00 1.00 1.00 1.00 0.16 303.75 2040.00 0.15 21.25 240.00 +0.60D+0.60W+0.60H 1.500 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 3.50 ft 1 0.040 0.024 1.60 1.500 1.00 1.00 1.00 1.00 1.00 0.04 81.00 2040.00 0.04 5.67 240.00 +0.60D+0.70E+0.60H 1.500 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 3.50 It 1 0.040 0.024 1.60 1.500 1.00 1.00 1.00 1.00 1.00 0.04 81.00 2040.00 0.04 5.67 240.00 Load Combination Span Max. '= Defl Location in Span Load Combination Max. "+' Defl Location in Span +O+S+H 1 0.0292 1.763 0.0000 0.000 Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MA)imum 0.210 .210 Overall MINimum 0.131 0.131 +D+H 0.079 0.079 +D+L+H 0.079 0.079 +D+Lr+H 0.079 0.079 +D+S+H 0.210 0.210 +D+0.750Lr+0.750L+H 0.079 0.079 +D+0.750L+0.750S+H 0.177 0.177 +D+0.60W+H 0.079 0.079 +D+0.70E+H 0.079 0.079 +D+0.750Lr+0.750L+0.450W+H 0.079 0.079 +D+0.750L+0.750S+0.450W+H 0.177 0.177 +D+0.750L+0.750S+0.5250E+H 0.177 0.177 +0.60D40.60W+0.60H 0.047 0.047 +0.60D+0.70E+0.60H 0.047 0.047 D Only 0.079 0.079 Lr Only L Only S Only 0.131 0.131 W Only E Only H Only 'i; Fr:�lUi=a1L'1t�I� k Description : ROOF (GARAGE) Cam Calculations per NDS 2015, IBC 2015, CBC Load Combination Set: IBC 2015 Material Properties Analysis Method : Load Resistance Factor D Fb + 900 psi E : Modulus of Elasticity Load Combination iBC 2015 Fb- 900psi Ebend-xx 1600ksi Fc - Prll 1350 psi Eminbend - xx 580ksi Wood Species Douglas Fir - Larch Fc - Perp 625 psi Wood Grade No.2 Fv 180 psi Beam Bracing Beam is Fully Braced against lateral -torsional buckling Ft 575 psi Density 31.21 pcf Repetitive Member Stress Increase 0 D(0 03) S(0 05) L � 1 k �i Span = 10.o ft Service loads entered. Load Factors will be applied for calculations. Uniform Load: D = 0.030, S = 0.01b, Tributary Width =1.0 ft ;;t�►ESlG;RIf= Maximum Bending Stress Ratio = 0.6881 Maximum Shear Stress Ratio = 0.215 : 1 Section used for this span 2x6 Section used for this span 2x6 j fb : Actual - 2,300.83 psi fv : Actual 96.22 psi j FB : Allowable = 3,342.22psi Fv: Allowable = 447.12 psi I Load Combination +1.20D+0.50L+1.60S+1.60H Load Combination +1.20D+0.50L+1.60S+1.60H i Location of maximum on span = 5.000ft Location of maximum on span = 0.000 ft i Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 i Maximum Deflection j Max Downward Transient Deflection 0.340 in Ratio = 352>=240 I Max Upward Transient Deflection 0.000 in Ratio = 0 <240 Max Downward Total Deflection 0.544 in Ratio = 220>=180 (i Max Upward Total Deflection 0.000 in Ratio = 0 <180 L-_ I Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V % C FN C i C r C m C t C L Mu fb Fb Vu fv Fv +1.40D+1.60H 0.00 0.00 0.00 0.00 Length = 10.0 ft 1 0.318 0.100 0.90 1.300 1.00 1.15 1.00 1.00 1.00 0.53 833.06 2615.65 0.19 34.84 349.92 +1.20D+0.50Lr+1.60L+1.60H 1.300 1.00 1.15 1.00 1.00 1.00 0,00 0.00 0.00 0.00 Length = 10.0 ft 1 0.197 0.061 1.25 1.300 1.00 1.15 1.00 1.00 1.00 0.45 714.05 3632.85 0.16 29.86 486.00 +1.20D+1.60L+0.50S+1.60H 1.300 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 10.0 ft 1 0.362 0.113 1.15 1.300 1.00 1.15 1.00 1.00 1.00 0.76 1,209.92 3342.22 0.28 50.60 447.12 +1.20D+1.60Lr+0.50L+1.60H 1.300 1.00 1.15 1.00 1.00 1,00 0.00 0.00 0.00 0.00 Length =10.0 ft 1 0.197 0.061 1.25 1.300 1.00 1.15 1.00 1.00 1.00 0.45 714.05 3632.85 0.16 29.86 486.00 +1.20D+1.60Lr+0.50W+1.60H 1.300 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 10.0 ft 1 0.154 0.048 1.60 1.300 1.00 1.15 1.00 1.00 1.00 0.45 714.05 4650.05 0.16 29.86 622.08 +1.20D+0.50L+1.60S+1.60H 1.300 1.00 1.15 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length =10.0 ft 1 0.688 0.215 1.15 1.300 1.00 1.15 1.00 1.00 1.0o 1.45 2,300.83 3342.22 0.53 96.22 447.12 Description : ROOF (GARAGE ) Load Combination Max Stress Segment Length Span # M Length =10.0 ft 1 0.495 +1.20D+0.50Lr+0.50L+W+1.60H Length =10.0 ft 1 0.154 +1.20D+0.50L+0.50S+W+1.60H Length =10.0 ft 1 0.260 +1.20 D+0.50 L+0.70 S+E+1.60 H Length =10.0 ft 1 0.303 +0.90D+W+0.90H Length =10.0 ft 1 0.115 +0.90D+E+0.90H Length =10.0 ft 1 0.115 � '� to V CF Ci Cr C C t 1•30 1.00 1.00 1.00 0.155 1.60 1.300 1.00 1.15 1.00 1.00 1.00 1.300 1.00 1.15 1.00 1.00 1.00 0.048 1.60 1.300 , 1.00 1.15 1.00 1.00 1.00 1.300 1.00 1.15 1.00 1,00 1.00 0.081 1.60 1.300 1.00 1.15 1.00 1.00 1.00 1.300 1.00 1.15 1.00 1.00 1.00 0.095 1.60 1.300 1.00 1.15 1.00 1.00 1.00 1.300 1.00 1.15 1.00 1.00 1.00 0,036 1.60 1.300 1.00 1.15 1.00 1.00 1.00 1.300 1.00 1.15 1.00 1.00 1.00 0.036 1.60 1.300 1.00 1.15 1.00 1.00 1.00 Moment Values Shear Values ib Fb Vu i'v Fv 0.00 0.00 0.00 0.00 1.45 2,300.83 4650.05 0.53 96.22 622.08 0.00 0.00 0,00 0.00 0.45 714.05 4650.05 0.16 29.86 622.08 0.00 0.00 0.00 0.00 0.76 1,209.92 4650.05 0.28 50.60 622.08 0.00 0.00 0.00 0.00 0.89 1,408.26 4650.05 0.32 58.89 622,08 0.00 0.00 0.00 0.00 0.34 535.54 4650.05 0.12 22.40 622.08 0.00 0.00 0.00 0.00 0.34 535.54 4650.05 0.12 22.40 622.08 Load Combination Span Max. ' " Deft Location in Span Load Combination Max. "+" Deti Location in Span +D+S+H 1 0.5441 5.036 0.0000 0.000 Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXtmum 0.400 0.400 Overall MINimum 0.250 0.250 +D+H 0.150 0.150 +D+L+H 0.150 0.150 +D+Lr+H 0.150 0.150 +D+S+H 0.400 0.400 +D+0.750Lr+0.750L+H 0.150 0.150 +D+0.750L+0.750S+H 0.338 0.338 +D+0.60W+H 0.150 0.150 +D+0.70E+H 0.150 0,150 +D+0.750Lr+0.750L+0.450W+H 0.150 0.150 +D+0.750L+0.750S+0.450W+H 0.338 0.338 +D+0.750L+0.750S+0.5250E+H 0.338 0.338 +0.600+0.60W+0.60H 0.090 0.090 +0.60D+0.70E+0.60H 0.090 0.090 D Only 0.150 0.150 Lr Only L Only S Only 0.250 0.250 W Only E Only H Only - EMEEMMMMMMEmi"MEMMEEI! �FORTE'CM I Tk�H -I-- I �� All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Member Reaction (lbs) 887 @ 17' 7 1/2" 1460 (3.50') Passed (61%) 1.00 1.0 D + 1.0 L (All Spans) Shear (lbs) 862 @ 17' 6 1/2" 1655 Passed (52%) 1.00 1.0 D + 1.0 L (AN Spans) Moment (Ft-lbs) 3120 @ 9110 3/8" 3795 Passed (82%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.310 @ 9' 0.431 Passed (L/668) 1.0 D + 1.0 L (All Spans) Total Load Defl. (in) 0.495 @ 9' 4 5/8" 0.863 Passed (L/418) 1.0 D + 0.75 L + 0.75 S (All Spans) TJ-Pro- Rating 42 40 Passed — Apo LZ���z ForteWES Software Operator lob Notes dong shin D.S. Engineering PC (425) 338-4776 shin_don@hotmail.com PASSED 0 System : Floor Member Type : Joist Building Use : Residential Budding Code : IBC 2015 Design Methodology: Aso ��-� 3 TOO Ew 2/16/2020 6:47:03 AM UTC ForteWEB v2.3, Engine: V8.0.0.21, Data: V7.3.2.0 Wcyert,— / me: Edmonds (� age l/1 3 A IaFORTEACM MEMBER REPORT PASSED 0 Ctvel, Floor'Joist Y 1 2 pieces) 11 7/8" T]I0 110 @ 16" OC Y veraff Length: 118' (,0096 T.� �• `�� 18' Al locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Member Reaction (lbs) 2018 @ 17 7 1/2" 3163 (3.50") Passed (64%) 1.15 1.0 D + 0.75 L + 0.75 S (All Spans) Shear (lbs) 1998 @ 17' 6 1/2" 3588 Passed (56%) 1.15 1.0 D + 0.75 L + 0.75 S (Al Spans) Moment (Ft-lbs) 5986 @ 14' 6" 7268 Passed (82%) 1.15 1.0 D + 0.75 L + 0.75 S (AII Spans) Live Load Defl. (in) 0.320 @ 9' 7 112" 0.431 Passed (L/647) -- 1.0 D + 0.75 L + 0.75 S (AN Spans) Total Load Defl. (in) 0.519 @ 9' 8 5/16" 0.863 Passed (L/398) 1.0 D + 0.75 L + 0.75 S (All Spans) TJ-Pro'" Rating 52 40 Passed • Top Edge Bracing (Lu): Top compression edge must be braced at 3' 2" o/c based on loads applied, unless detailed otherwise. • Bottom Edge Bracing (Lu): Bottom compression edge must be braced at 17' 10" o/c based on loads applied, unless detailed otherwise. • A structural analysis of the deck has not been performed. • Deflection analysis is based on composite action with a single layer of dec king_2332Edge that is gluedAndNailedDown. • Additional considerations for the T}ProTM Rating include: None. 1 - Stud wall - HF 1 5.50" 1 4.25" 1.75" 293 480 249 1022 1 1/4" Rim Board 2 -Stud wall - HF 5.50" IF .25" 1 1.75" 820 1 480 1126 2426 11 1/4" Rim Board • Rim Board is assumed to carry all loads applied directly above it, bypassing the member beinq designed. 0 System : Floor Member Type : Joist Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD pl- PSF)0 to 18, 16^ 12.0 40,p _ p� Load 2 -Point (lb) 14' 6" N/A 825 1375 �� fT�1 Sr _ Weyerhaeuser warrants that the slzirg of its products will be In accordance with Weyerh product design criteria and pub heel design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a d 'gn professional as determined by authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall Project. Accessories 'm Board, Blocking Panels and Squ Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -parry certified to sustainable forestry standards. Weyerhae ngineered Lumber Products hav n evaluated by ICC-ES under evaluation reports ESR-1153 and FSR-1387 and/or tested in accordance with applicable ASTM standards. For current oode evaluation reports, erhaeuser product literature a installation details refer to www.weyerhaetiser.cDm/woodPrc)ducts/document-library. The product application, input design loads, dimensions and support Information have been provided by Forte Software Operator 1 11 /0 1 11 1 /Z+; FwteWEB Software orator Job Notes dong shin D.S. Engineering PC (425)338-4776 shlrl--don@hobmil.com mail.com 2/16/2020 6:42:20 AM IJTC ForteWEB v2.3, Engine: V8.0.0.21, Data: V7.3.2.0 �eyerhaeusa a e: Edmonds age i/1 30'I I I ITEM �I;;� Wood Beam I Description : header -� CODE REFERENCES Calculations per NDS 2015, IBC 20 , 2016, ASCE 7-10 Load Combination Set: IBC 2015 Material Properties Analysis Method: Allowable Stress Design Fb + 2400 psi E : Modulus of Elasticity Load Combination IBC 2015 Fb - 1850 psi Ebend- xx 1800ksi Fc - Prll 1650 psi Eminbend - xx 950 ksi Wood Species : DF/DF Fc - Perp 650 psi Ebend- yy 1600ksi Wood Grade : 24F - V4 Fv 265 psi Eminbend - yy 850ksi Ft 1100 psi Density 31.21 pcf Beam Bracing : Beam is Fully Braced against lateral -torsional buckling _D�0t 9 2IS 0� 175� - o ---- - Y 5.5x9 1 i " 1 (O .Z 1I ( 4�an = 8 50ft _ ""�-...ia..._._...._.._..._...__.......__._._T M....._.................._..... _-__..._......................... -----.................._....._._I Applied Loads- . ((� Service loads entered. Load Factors will be applied for calculations. Beam self weight calcul tCanddd loadsUniformLoad: D=0..2 , S = 0.1750 , Tributary Width =�.'_-0 DESIGN- SUMMARY . 'Maximum Bending Stress Ratio Section used for this span fb : Actual FB : Allowable Load Combination Location of maximum on span Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection Max Upward Transient Deflection Max Downward Total Deflection Max Upward Total Deflection = 0.260: 1 5.5x9 = 718.09psi 2,760.00psi +D+0.750L+0.750S+H 4.250 ft = Span # 1 0.039 in Ratio = 0.000 In Ratio = 0.097 in Ratio = 0.000 in Ratio = ,num Stttlar Stress Ratio Section used for this span fv : Actual Fv: Allowable Load Combination Location of maximum on span Span # where maximum occurs 2596 >=360 0 <360 1055 >=180 0 <180 0.171 : 1 5.5x9 52.26 psi 304.75 psi +D+0.750L+0.750S+H 0.000 ft = Span # 1 u. esses for Load Combinations Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V C d C FN C i Cr C m C t C L M fb Fb V fv Fv +D+H 0.00 Length = 8.50 ft 1 0.142 0.094 0.90 1.000 1.00 1.00 1.00 1.00 1.00 1.90 307.58 2160.00 +D+L+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 Length = 8.50 ft 1 0.250 0.165 1.00 1.000 1.00 1.00 1.00 1.00 1.00 3.71 599.50 2400.00 +D+Lr+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 Length = 8.50 ft 1 0.103 0.068 1.25 1,000 1.00 1.00 1.00 1.00 1.00 1.90 307.58 3000.00 +D+S+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 Length = 8.50 ft 1 0.204 0.134 1.15 1.000 1.00 1.00 1.00 1.00 1.00 3.48 563.01 2760.00 +D+0.750Lr+0.750L+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 Length = 8.50 ft 1 0.176 0.116 1.25 1.000 1.00 1.00 1.00 1.00 1.00 3.26 526.52 3000.00 +D+0.750L+0.750S+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 0.74 22.38 238.50 0.00 0.00 0.00 1.44 43.63 265.00 0.00 0.00 0.00 0.74 22.38 331.25 0.00 0.00 0.00 1.35 40.97 304.75 0.00 0.00 0.00 1.26 38.32 331.25 0.00 0.00 0.Q0_ _ r I Wood Beam Description : header Load Combination Max Stress Ratios CL�D Segment Length Span # M V C d C FN C i Cr C m C t C L Moment Values Shear Values M fb F'b V fv F'v Length = 8.50 ft 1 0.260 0.171 1.15 1.000 1.00 1.00 1.00 1.00 1.00 4.44 718.09 2760.00 1.72 52.26 304.75 +D+0.60W+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 8.50 ft 1 0.080 0.053 1.60 1.000 1.00 1.00 1.00 1.00 1.00 1.90 307.58 3840.00 0.74 22.38 424.00 +D+0.70E+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 8.50 ft 1 0.080 0.053 1.60 1.000 1.00 1.00 1.00 1.00 1.00 1.90 307.58 3940.00 0.74 22.38 424.00 +D+0.750Lr+0.750L+0.450W+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 8.50 ft 1 0.137 0.090 1.60 1.000 1.00 1.00 1.00 1.00 1.00 3.26 526.52 3840.00 1.26 38.32 424.00 +D+0.750L+0.750S+0.450W+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 8.50 ft 1 0.187 0.123 1.60 1.000 1.00 1.00 1.00 1.00 1.00 4.44 718.09 3840.00 1.72 52.26 424.00 +D+0.750L+0.750S+0.5250E+H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 8.50 ft 1 0.187 0.123 1.60 1.000 1.00 1.00 1.00 1.00 1.00 4.44 718.09 3840.00 1.72 52.26 424.00 +0.60D+0.60W+0.60H 1.000 1.00 100 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 8.50 ft 1 0.048 0.032 1.60 1.000 1.00 1.00 1.00 1.00 1.00 1.14 184.55 3940.00 0.44 13.43 424.00 +0.60D+0.70E+0.60H 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 8.50 ft 1 0.048 0.032 1.60 1.000 1.00 1.00 1.00 1.00 1.00 1.14 184.55 3840.00 0.44 13.43 424.00 Overall Maximum Deflections Load Combination Span Max. "" Defl Location in Span Load Combination Max. "+" Defl Location in Span +D+0.750L+0.750S+0.5250E+H 1 0.0966 4.281 0.0000 0.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 2.091 2.091 Overall MINimum 0.744 0.744 +D+H 0.896 0.896 +D+L+H 1.746 1.746 +D+Lr+H 0.896 0.896 +D+S+H 1.639 1.639 +D+0.750Lr+0.750L+H 1.533 1.533 +D+0.750L+0.750S+H 2.091 2.091 +D+0.60W+H 0.896 0.896 +D+0.70E+H 0.896 0.896 +D+0.750Lr+0.750L+0.450W+H 1.533 1.533 +D+0.750L+0.750S+0.450W+H 2.091 2.091 +D+0.750L+0.750S+0.5250E+H 2.091 2.091 +0.60D+0.60W+0.60H 0.537 0.537 +0.60D+0.70E+0.60H 0.537 0.537 D Only 0.896 0.896 Lr Only L Only 0.850 0.850 S Only 0.744 0.744 W Only E Only H Only