APPROVED BLD BLD2021-0808+Architectural_Plan+6.13.2021_10.30.08_PM+2246922CRITERIA 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE 2018 INTERNATIONAL BUILDING CODE. 2.DESIGN LOADING CRITERIA: EARTHQUAKE . . . ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE LATERAL SYSTEM: LIGHT FRAMED WOOD SHEAR WALLS SITE CLASS=D, Ss=1.280, Sds=1.024, S1=0.450, SD1=0.555, Cs=O. 158, SDC D, Ie=1.0, R=6.5 3.CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE CONTRACTORS WORK. THE STRUCTURAL ENGINEER HAS NO OVERALL SUPERVISORY AUTHORITY OR ACTUAL AND/OR DIRECT RESPONSIBILITY FOR THE SPECIFIC WORKING CONDITIONS AT THE SITE AND/OR FOR ANY HAZARDS RESULTING FROM THE ACTIONS OF ANY TRADE CONTRACTOR. THE STRUCTURAL ENGINEER HAS NO DUTY TO INSPECT, SUPERVISE, NOTE, CORRECT, OR REPORT ANY HEALTH OR SAFETY DEFICIENCIES TO THE OWNER, CONTRACTORS, OR OTHER ENTITIES OR PERSONS AT THE PROJECT SITE. 4.CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS. CONFORM TO ASCE 37-02 "DESIGN LOADS ON STRUCTURES DURING CONSTRUCTION". 5. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE STRUCTURAL ENGINEER. ALL TYPICAL AND NOTES SHOWN ON DRAWINGS SHALL APPLY, UNLESS NOTED OTHERWISE. TYPICAL DETAILS MAY NOT NECESSARILY BE INDICATED ON THE PLANS BUT SHALL STILL APPLY AS SHOWN OR DESCRIBED IN THE DETAILS. WHERE TYPICAL DETAILS ARE NOTED ON THE PLANS, THE SPECIFIED TYPICAL DETAIL SHALL BE USED. WHERE NO TYPICAL DETAIL IS NOTED, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO CHOOSE THE APPROPRIATE TYPICAL DETAIL FROM THOSE PROVIDED. THE CONTRACTOR SHALL SUBMIT ALL PROPOSED ALTERNATE TYPICAL DETAILS TO THOSE PROVIDED WITH RELATED CALCULATIONS TO THE ENGINEER FOR APPROVAL PRIOR TO SHOP DRAWING PRODUCTION AND FIELD USE. RENOVATION 6.DEMOLITION: CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS BEFORE COMMENCING ANY DEMOLITION. SHORING SHALL BE INSTALLED TO SUPPORT EXISTING CONSTRUCTION AS REQUIRED AND IN A MANNER SUITABLE TO THE WORK SEQUENCES. DEMOLITION DEBRIS SHALL NOT BE ALLOWED TO DAMAGE OR OVERLOAD THE EXISTING STRUCTURE. LIMIT CONSTRUCTION LOADING (INCLUDING DEMOLITION DEBRIS) ON EXISTING FLOOR SYSTEMS TO 40 PSF. 7.CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES, AND CONDITIONS PRIOR TO COMMENCING ANY WORK, ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. 8.CONTRACTOR SHALL CHECK FOR DRYROT AT ALL AREAS OF NEW WORK. ALL ROT SHALL BE REMOVED AND DAMAGED MEMBERS SHALL BE REPLACED OR REPAIRED AS DIRECTED BY THE STRUCTURAL ENGINEER OR ARCHITECT. ANCHORAGE 9.EXPANSION BOLTS INTO CONCRETE SHALL BE STRONG BOLT 2 WEDGE ANCHORS AS MANUFACTURED BY THE SIMPSON STRONG TIE COMPANY AND INSTALLED IN STRICT CONFORMANCE TO ICC-ES REPORT NUMBER ESR-3037, INCLUDING MINIMUM EMBEDMENT REQUIREMENTS. BOLTS INTO CONCRETE MASONRY OR BRICK MASONRY UNITS SHALL BE INTO FULLY GROUTED CELLS. 10. EPDXY -GROUTED ITEMS (THREADED RODS OR REINFORCING BAR) SPECIFIED ON THE DRAWINGS SHALL BE INSTALLED USING "SET-XP" HIGH STRENGTH EPDXY AS MANUFACTURED BY THE SIMPSON STRONG, TIE COMPANY. INSTALL IN STRICT ACCORDANCE WITH ICC-ES REPORT NO. ESR-2508. RODS SHALL BE ASTM A-36 UNLESS OTHERWISE NOTED. 11. CONCRETE SCREW ANCHORS INTO CONCRETE AND CONCRETE MASONRY UNITS SHALL BE TITEN HD HEAVY DUTY SCREW ANCHOR AS MANUFACTURED BY THE SIMPSON STRONG -TIE CORP., INSTALLED IN STRICT ACCORDANCE WITH ICC-ES REPORT NO. ESR-2713 (CONCRETE), NO. ESR-1056 (CMU), INCLUDING MINIMUM EMBEDMENT REQUIREMENTS. SCREW ANCHORS INTO CONCRETE MASONRY UNITS SHALL BE INTO FULLY GROUTED CELLS. SUBSTITUTES PROPOSED BY CONTRACTOR SHALL BE SUBMITTED FOR REVIEW WITH ICBO, OR ICC REPORTS INDICATING EQUIVALENT OR GREATER LOAD CAPACITIES. WOOD 12. FRAMING LUMBER SHALL BE KILN DRIED OR MC-19, AND GRADED AND MARKED IN CONFORMANCE WITH W.C.L.B. STANDARD GRADING RULES FOR WEST COAST LUMBER NO. 17. FURNISH TO THE FOLLOWING MINIMUM STANDARDS: ALL STRUCTURAL WOOD DOUGLAS-FIR-LARCH OR HEM -FIR NO. 2 13. PLYWOOD SHEATHING SHALL BE GRADE C-D, EXTERIOR GLUE OR STRUCTURAL II, EXTERIOR GLUE IN CONFORMANCE WITH DOC PS 1 OR PS 2. ORIENTED STRAND BOARD OF EQUIVALENT THICKNESS, EXPOSURE RATING AND PANEL INDEX MAY BE USED IN LIEU OF PLYWOOD. WALL SHEATHING SHALL BE 1/2" (NOMINAL) WITH SPAN RATING 24/0. REFER TO WOOD FRAMING NOTES BELOW FOR TYPICAL NAILING REQUIREMENTS. 14. ALL WOOD IN DIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE -TREATED WITH AN APPROVED PRESERVATIVE OR (2) LAYERS OF ASPHALT IMPREGNATED BUILDING PAPER SHALL BE PROVIDED BETWEEN UNTREATED WOOD AND CONCRETE OR MASONRY. General Structural Notes THE FOLLOWING APPLY UNLESS SHOWN OTHERWISE ON THE DRAWINGS 15. PRESSURE TREATED WOOD (INCLUDES PRESERVATIVE AND FIRE TREATED)SHALL BE TREATED PER AWPA STANDARD. PRESSURE TREATED WOOD FOR ABOVE GROUND USE SHALL BE TREATED TO RETENTION OF 0.25 PCF. WOOD IN CONTINUOUS CONTACT WITH FRESH WATER OR SOIL SHALL BE TREATED TO A RETENTION OF 0.40 PCF. WOOD FOR USE IN PERMANENT FOUNDATIONS SHALL BE TREATED TO A RETENTION OF 0.60 PCF. SODIUM BORATE (SBX) TREATED WOOD SHALL NOT BE USED WHERE EXPOSED TO WEATHER. FASTENERS AND TIMBER CONNECTORS WITHOUT AMMONIA IN DIRECT CONTACT WITH ACQ-A (UP TO A RETENTION LEVEL OF 0.40 PCF), CBA-A (UP TO A RETENTION LEVEL OF 0.41 PCF), CA-B (UP TO A RETENTION LEVEL OF 0.21 PCF), OR SBX TREATED WOOD SHALL BE C185 OR A185 HOT DIPPED OR CONTINUOUS HOT -GALVANIZED PER ASTM A653. FASTENERS AND TIMBER CONNECTORS WITH AMMONIA IN DIRECT CONTACT WITH ACQ-A (OVER A RETENTION LEVEL OF 0.40 PCF), CBA-A (OVER A RETENTION LEVEL OF 0.41 PCF), CA-B (OVER A RETENTION LEVEL OF 0.21 PCF), OR WITH ACZA TREATED WOOD SHALL BE TYPE 304 OR 316 STAINLESS STEEL. 16. TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, AS SPECIFIED IN THEIR CATALOG NUMBER C-2011. EQUIVALENT DEVICES BY OTHER MANUFACTURERS MAY BE SUBSTITUTED, PROVIDED THEY HAVE ICC-ES APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES PROVIDE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER FOR MAXIMUM LOAD CARRYING CAPACITY. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. ALL SHIMS SHALL BE SEASONED AND DRIED AND THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. 17. WOOD FASTENERS A.NAIL SIZES SPECIFIED ON DRAWINGS ARE BASED ON THE FOLLOWING SPECIFICATIONS: SIZE LENGTH DIAMETER 8d 2-112)) 0. 131" 16d 3-1/2" 0. 135" IF CONTRACTOR PROPOSES THE USE OF ALTERNATE NAILS, THEY SHALL SUBMIT NAIL SPECIFICATIONS TO THE STRUCTURAL ENGINEER (PRIOR TO CONSTRUCTION)FOR REVIEW AND APPROVAL. NAILS - PLYWOOD (APA RATED SHEATHING) FASTENERS TO FRAMING SHALL BE DRIVEN FLUSH TO FACE OF SHEATHING WITH NO COUNTERSINKING PERMITTED. SPECIAL INSPECTION(S) REQUIRED FOR THIS PROJECT: 1) EPDXY �2) BOLTING IN CONCRETE B. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG BOLTS BEARING ON WOOD. INSTALLATION OF LAG BOLTS SHALL CONFORM TO THE NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION WITH A LEAD BORE HOLE OF 60 TO 70 PERCENT OF THE SHANK DIAMETER. LEAD HOLES ARE NOT REQUIRED FOR 3/8" AND SMALLER LAG SCREWS. 18. WOOD FRAMING NOTES --THE FOLLOWING APPLY UNLESS OTHERWISE SHOWN ON THE PLANS: A. ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO THE MINIMUM STANDARDS OF THE INTERNATIONAL BUILDING CODE, THE AITC "TIMBER CONSTRUCTION MANUAL" AND THE AF&PA "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION". MINIMUM NAILING, UNLESS OTHERWISE NOTED, SHALL CONFORM TO IBC TABLE 2304.9.1. COORDINATE THE SIZE AND LOCATION OF ALL OPENINGS WITH MECHANICAL AND ARCHITECTURAL DRAWINGS. B.WALL FRAMING: REFER ARCHITECTURAL DRAWINGS FOR THE SIZE OF ALL WALLS. ALL STUDS SHALL BE SPACED AT 16" 0. C. UNO. TWO STUDS M I N I MUM SHALL BE PROVIDED AT THE END OF ALL WALLS AND AT EACH SIDE OF ALL OPENINGS, AND AT BEAM OR HEADER BEARING LOCATIONS. ALL NEW WALLS SHALL HAVE A SINGLE BOTTOM PLATE AND A DOUBLE TOP PLATE. END NAIL TOP PLATE TO EACH STUD WITH TWO 16d NAILS, AND TOENAIL OR END NAIL EACH STUD TO BOTTOM PLATE WITH TWO 16d NAILS. FACE NAIL DOUBLE TOP PLATE WITH 16d @ 12" O.C. AND LAP MINIMUM 4'-0" AT JOINTS AND PROVIDE EIGHT 16d NAILS @ 4" O.C. EACH SIDE JOINT. ALL NEW STUD WALLS SHALL HAVE THEIR LOWER WOOD PLATES ATTACHED TO WOOD FRAMING BELOW WITH TWO ROWS OF 16d NAILS @ 12" ON -CENTER, OR ATTACHED TO CONCRETE BELOW WITH 5/8" DIAMETER ANCHOR BOLTS @ 4'-0" ON -CENTER EMBEDDED 7" MINIMUM, UNLESS INDICATED OTHERWISE. INDIVIDUAL MEMBERS OF BUILT-UP POSTS SHALL BE NAILED TO EACH OTHER WITH TWO ROWS OF 16d @12" ON -CENTER. UNLESS OTHERWISE NOTED, GYPSUM WALLBOARD SHALL BE FASTENED TO THE INTERIOR SURFACE OF ALL STUDS AND PLATES WITH NO. 6 X 1-1/4" TYPE S OR W SCREWS @ 8" ON -CENTER. ENERGY CODE 19. EXISTING CEILING, WALL, OR FLOOR CAVITIES EXPOSED DURING CONSTRUCTION SHALL BE FILLED WITH INSULATION PER 2018 INTERNATIONAL ENERGY CODE, PRESCRIPTIVE APPROACH: R101.4.3, EXCEPTION 3. 2x 4 FRAMED WALLS SHALL BE INSULATED TO A MINIMUM OF R-15 AND 2x6 FRAMED WALLS SHALL BE INSULATED TO A MINIMUM OF R-21. APPROVED PLANS MUST BE ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE City Of Edmonds Building Department Work SEISMIC RETRO FIT Address 1452 8TH PL S Owner FRIEL Approved Date 7/02/2021 Building OfficialVOWArvo-OLW W pf&QIL Permit Number BLD2021-0808 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..................... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....................2/S2.1.>........................................................ ...................... . . . . . . . . . . . . . . . . . ...........................4.0:':::.................................................................I....... :::::^. 2/S2..1: .................................... 1/S2.1................................. �. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . :�81.................................. .1)S2.,1 . : : : . . . . . . . . . . . . . . . . . . . . . . . . . ..................................... ... . ... :. S I.N/j : :: ::: :: : :: :::.: : 1 /S2.1: ... ... .. . ... . . . . . .. . . . . . . ... . .. . . . .. . . ... . . ......................................................................................................... ....................................................................Residence ofJohn. Friel ................. .............................................I...................... Address:'. 1452 '8th'PI'S :Edr�no:n�d's' WA �9�8020 .................................................................::: ................................................................. Parcel:N u mbar.::0:0:565500001000: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Leaend 0 HDUx .. I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..................................... -/ . . . . . . . . . . . . . Q�� . .............. ..................... . . . . :: .... x .car decking :over . . . .... . ..... ... .................................. ara e :: :: . :: :: ...... yp�. 30,...............E .................................1/S2.1. : . ................ ..................................... ................ ..................................... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..................................... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............. . . .�7 . . . . . . . . . . . . INDICATES AREA OF SEISMIC RETROFIT UPGRADE HOLDOWN TO DBL. END STUD, REF. DETAIL SHEET S2.1 Retrofit Plan - Scale: 1/8» - 1'- 0" ATIC Hazards by Location Search Information Address: 1452 8th PI S, Edmonds, WA 98020, USA Coordinates: 47.7943456,-122.3677689 Elevation: 299 ft Timestamp: 2021-06-11 T03:08:11.847Z Hazard Type: Seismic Reference ASCE7-16 Document: Risk Category: II Site Class: D-default Basic Parameters Name Value SS 1.28 S1 0.45 SMS 1.536 SM1 null SIDS 1.024 SD1 " null * See Section 11.4.8 Go gle Description MCER ground motion (period=0.2s) MCER ground motion (period=1.0s) Site -modified spectral acceleration value Site -modified spectral acceleration value Numeric seismic design value at 0.2s SA Numeric seismic design value at 1.0s SA Additional Information Name Value Description SDC * null Seismic design category Fa 1.2 Site amplification factor at 0.2s Fv null Site amplification factor at 1.0s CRS 0.911 Coefficient of risk (0.2s) CR1 0.896 Coefficient of risk (1.0s) PGA 0.543 MCEG peak ground acceleration FPGA 1.2 Site amplification factor at PGA PGAM 0.652 Site modified peak ground acceleration Seismic Retrofit (SBC 2018/ASCE 7-161 Seismic Criteria: OCCUPANCY CATEGORY: II NO. STORIES ABV. GR. 2 IMPORTANCE FACTOR: 1.0 SITE CLASS D (Default) SDS= 1.024 R = 6.5 Spy= 0.555 h = 24 ft Period, T= 0.217 SS = 1.280 CS 0.158 S, = 0.450 Csmaz 0.394 Fa = 1.2 Csmin 0.010 F = 1.85 Controlling CS 0.158 Building Weight Floor DL (psf) A (sq.ft.) W (Ibs) Roof 20 1800 36000 2nd 22 1800 39600 Brick Veneer 40 300 12000 0 Sum= 87600 Wall Seismic Loading: 299 ft rAh Si SW Epe C Map data ©2021 Google Section 12.8.1.3 Exceptions Regular Structure- Yes <_ 5 Stories above grade Yes Yes T 5 0.5s p =1.0 No Not Site Class E or F Yes Risk Category I or II Yes it aii exceptions are met, aps may oe taKen as t, out not less than 0.7*(Calculated Sos) **Regular Structure per Section 12.3.2 Redundancy Factor, p = 1.3 Base Shear, VBASE = 17940 Ibs VAso = 3VBase = 12558 Ibs Wall V (Ibs) Wall (ft) v (Ibs/ft) North Exterior 6279 38.0 165 South Exterior 6279 46.0 137 West Exterior 6279 28.0 224 East Exterior 6279 22.0 285 Sill Plate Bolting: Maximum Anchor Spacing For Various Retrofit Anchor Options Wall 1/2" Dia Titen HD URFP FRFP SDS Option @ Rim North Exterior 48 in oc 72 in oc 72 in oc 16 in oc South Exterior 48 in oc 72 in oc 72 in oc 16 in oc West Exterior 32 in oc 48 in oc 48 in oc 16 in oc East Exterior 32 in oc 48 in oc 48 in oc 16 in oc Pony Wall Retrofit: Wall North South Garage West East Garage Hw (ft) Edge Nailing A35/1-70 Uplift (Ibs) Trib DL (Ibs) Net Uplift (Ibs) Holdown Min. Lw w/ no HD 0.0 8d@4 16 in oc 0 0 0 None N/A 7.0 8d@4 16 in oc 956 225 821 HDU2 N/A 0.0 8d@4 16 in oc 0 0 0 None N/A 7.0 8d@4 16 in oc 1998 450 1728 HDU2 N/A 'RUCTURAL IGINEERING 2124 Third Avenue - Suite too - Seattle, WA 98121 p:2o6.443.6212 ssfengineers.com I� 6-11-21 DRAWN: RJA DESIGN: RJA CHECKED: RJA APPROVED: RJA CLIENT: Seattle Seismic PO Box 33787 Seattle, WA 98133 p: 206-384-6585 e: ryan@seattleretrofit.com PROJECT TITLE: Friel Retrofit 1452 8th PI. S. Edmonds, WA 98020 REVISIONS: ISSUE: Permit SHEET TITLE: Structural Notes Plan and Calculations SC 3/4"=1'-0" LINO DATE: June 11, 2021 PROJECT NO: 11208-2021-11 SHEET NO: S1 • NO: OF SHEETS: s cn 0 Q APPROVALS: RECEIVED Z Jun 16 2021 c='n CITY OF EDMONDS N DEVELOPMENT SERVICES N DEPARTMENT 0 0 (E) WALL ABOVE PROVIDE L70 CLIPS @ 16"oc, INSTALL W/ PALM NAILER ASSUMED (E) NAILING AT (E) RIM (E) JOISTS &SHEATHING VERIFY (E) 2x RIM OR FULL —DEPTH BLKG. PROVIDE 1/2" CDX PLYWOOD, (E) PONY WALL BLOCK EDGES & NAIL W/ 8d @ 4"oc EDGES, 12"oc FIELD (E) SILL PLATE W/ NEW HDU2—SDS2.5 W/ 1/2"0 TITEN1 HD CONC. SCREWS (6)SDS�/4x2�/2 SCREWS @ 32"oc (3/2" conc. embed) TO DOUBLE STUDS (where occurs) EPDXY GROUT 5/8" 0 THREADED ROD 8"(min.) INTO (E) CONCRETE @ NEW HD LOCATIONS, INSTALL PROVIDE 1/4"x3"x3" STEEL @ SLIGHT ANGLE TO ACHIEVE ' PLATE WASHER @ NEW SILL EDGE DISTANCE .,,1ll;J a a PLATE ANCHORAGE LJ /� 23/4 min. ° a ° ° (E) FOUNDATION Retrofit Detail PROVIDE 12" WIDE (E) WALL ABOVE — 1/2" CDX PLYWOOD PRENAILED TO LEDGER W/ 8d @ 4"oc ASSUMED (E) NAILING (E) 2x CAR DECKING, FIELD VERIFY a (E) 2x SILL PLATE _ cV ° a NAIL PLYWOOD TO (E) CAR DECKING W/ (3) ROWS 8d x 2" COMMON NAILS @ 3"oc (E) FOUNDATION WALL a PROVIDE 10d @ 4"oc LEDGER TO (E) NAILER PROVIDE P.T. 2x10 LEDGER W/ 1/2" 0 x 5" TITEN HD CONC. SCREWS @ 32"oc (48"oc @ SIM) ALL FASTENERS INTO PRESSURE TREATED WOOD SHALL BE GALV. OR STAINLESS STEEL PER GENERAL STRUCTURAL NOTES Retrofit Detail 2 Nx�/ STRUCTURAL ENGINEERING 2124 Third Avenue - Suite loo - Seattle, WA 98121 P: 2o6.443.6212 ssfengineers.com 6-11-21 DRAWN: RJA DESIGN: RJA CHECKED: RJA APPROVED: RJA CLIENT: Seattle Seismic PO Box 33787 Seattle, WA 98133 p: 206-384-6585 e: ryan@seattleretrofit.com PROJECT TITLE: Friel Retrofit 1452 8th PI. S. Edmonds, WA 98020 REVISIONS: IS Permit SHEET TITLE: Retrofit Details SCALE: 3/4"=1'-O" UNO DATE: June 11, 2021 PROJECT NO: 11208-2021-11 SHEET NO: S2,01 NO: OF SHEETS: ' APPROVALS: RECEIVED Jun 16 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT