ENG2021-0171 ROW PERMITRIGHT OF WAY EUC PERMIT
PERMIT NUMBER
City of • • •
Edmonds98020 1 1
www.cityofedmonds.gov
Description: COMCAST-INSTALLING 2" CONDUIT, BORING & NEW CARSON BOX
ISSUED: 08/02/2021
Address: 20312 92ND AVE W EDMONDS WA 98020-2984
EXPIRES: 02/02/2022
rmit Type: RIGHT OF WAY EUC Permit Subtype: STANDARD Parcel Number: 00572800000202
i
NAME TYPE NAME ADDRESS PHONE
APPLICANT COMCAST 1525 75TH ST SW, EVERETT WA 98203 (425)921-8201
CONTRACTOR SPECTRA BROADBAND INC. , BURLINGTON WA 98233-4606 (801)546-1550
OWNER HARDTKE JAMES K 20312 92ND AVE W, EDMONDS WA 98020-2984
FEE INFORMATION
DESCRIPTION AMOUNT PAID
CITY TECHNOLOGY FEE CHARGED PER PERMIT
$40.00 $0.00
RIGHT OF WAY STANDARD - EUC PERMIT FEE
$330.00 $0.00
•
REQUIREMENT TYPE NOTES
TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City
Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification
verifying completion of the required training in their posession.
RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with
asphalt or City approved material prior to the end of the workday - No Exceptions
WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final
inspection and acceptance of the work.
INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM
24 HR NOTICE REQUIRED
INDEMNITY
The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of
any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments
or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of
granting this permit.
THIS DOCUMENT IS NOT VALID UNTIL FEES ARE PAID AND THE CITY ENGINEER OR HIS/HER DEPUTY HAS SIGNED BELOW
08/02/2021
RELEASED BY
DATE
Printed: Monday, August 02, 2021 12:25:36 PM 1 of 2
-KRWOF WAY EUC PERMIT
City of • • •
•:• •ENG2021-01711
www.cityofedmonds.gov• •
CONDITIONS
CONDITION TYPE
Easement and/or permission from adjacent property owner is required prior to entry or work within
ADJACENT PROPERTY
an adjacent property.
It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in
DAMAGE TO FRONTAGE
City right of Ways or Easements to City Standards caused by or occurring during the permitted
IMPROVEMENTS
project.
Alert affected residents and/or businesses prior to work start.
Verify clear bore crossings.
ENGINEERING OTHER
Restore landscape to like or better conditions.
Call for required inspections as noted.
ESC REQ
Maintain erosion and sedimentation control per City and SWMMW standard requirements.
Sound/Noise originating from temporary construction sites as a result of construction activity are
exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:OOam to 6:OOpm on
SOUND OR NOISE
weekdays and 10:OOam and 6:OOpm on Saturdays, excluding Sundays and Federal Holidays. At all
other times the noise originating from construction sites/activities must comply with the noise limits
of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120.
TRAFFIC CONTROL
Traffic Control per approved plan and MUTCD. All Flaggers shall be certified.
All utilities shall be located prior to any excavation. New locates shall be called for if at time of
UTILITY LOCATES
excavation, original locates are no longer identifiable.
INSPECTIONS
INSPECTION TYPE
DATE
RESULT
COMPLETE
A-1 JOB START
X-2 ENGINEERING FINAL"
E-7 RESTOR LIMITS
E-7 CONCRETE SIDEWALK
Printed: Monday, August 02, 2021 12:25:36 PM 2 of 2
Include an overall narrative description of the proposed work. Be specific and detailed:
Describe infrastructure to be impacted, such as, poles, wires, conduit, utility mains, etc.
Include whether this is construction, maintenance, or repair.
Include description of proposed construction methods, (e.g., bores, trenches, overhead wires proposed, depth for
underground utilities, etc.)
we will be installing a 2inch conduit to install Comcast service starting from the PED located next to house 20308, we will bore 48ft right crossing under driveway for house 20308 in
the ROW then placing a new flush mount carson box at property line for house 20312. We will maintain a 5ft horizontal clearance from all utilities
RIGHT-OF-WAY
CLOSURE
AREA
TOTAL
DURATION
(Number of Months)
Sidewalk 72 hours +
LF
I x
LF
SF
Alley 72 hours +
LF
Ix
I LF
SF
Parking 72 hours +
LF
Ix
I LF
SF
SECTION B - If you are not a utility company performing work in the City ROW, skip to SECTION C.
1. The work in the right of way is on or for the following type of facilities:
❑ telecommunications o cable ❑ power ❑ gas
❑ water ❑ sewer ❑ storm
Details of Work to be Completed
1. Does the utility owner have existing overhead infrastructure in the area of work?
Yes
No
x
2. Will any equipment be added underground or above ground (e.. pedestals, vaults, etc.)?
x
If yes, describe: flush mount carson box
3.
Does the proposed work connect a lot or commercial development with utilities that serve more
than one lot or commercial development?
X
4.
Does the work involve rebuilding or relocating an existing aboveground utility system which
connects a lot or commercial development to an existing underground common utility stem?
X
5.
Does the work involve proposed additions to an aboveground utility stem? If es:
x
Are the additions for the purpose of serving new commercial development?
x
Are the additions for the purpose of serving a single-family residential subdivision?
x
Details
of Work to be Completed
Yes
No
6.
Does your project involve rebuilding or replacing utility equipment which currently serves more
than one lot or commercial development?
X
If yes, answer the following questions related to project area, i.e. the actual area in which the
project is proposed:
6a.
Does your project involve wires/cables/lines? If yes:
X
How many are existing? I I How many are to be added?
City of Edmonds ROW construction permit Application --Page 2 of 3 Updated 3/25/2021
6b.
Does your project involve poles? If yes:
How many poles are existing in the project area?
What is the height of the existing poles?
How many poles are to be removed?
Are additional poles to be laced?
How many? I I What is the height of the additionalpoles?
6c.
Are any poles to be modified/rebuilt/replaced? If yes:
X
How many? I I What is the height of the poles after?
Describe the modification rebuild:
SECTION C
Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as
required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have
certification verifying completion of the required training in their possession.
Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be
patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS.
Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to
any permit approval.
Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials,
officers, employees, and agents against any injuries, damages, or claims of any kind or description whatsoever,
foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectly from any act or
omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose
acts or omissions they may be liable, arising out of, related to, or by reason of the granting of this permit; and
specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any
respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the
expiration, revocation, or termination of any resulting permit approval.
Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and
requirements set forth in this Application and agrees they apply to any resulting permit and shall comply with them to
the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal
Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable
requirements of state and federal law.
Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a
licensed and bonded contractor; the information provided herein is correct and complete; and I am authorized by
owner to act on its behalf and have authority to bind the owner to this application.
Fees. The Applicant is responsible for all permit fees.
APPLICANT SIGNATURE: Marissa Sena DATE: 5/10/2021
APPLICANT PRINTED NAME: Maritsa .S'Pna
APPLICANT TITLE: Drop Bury Admin
NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE
City of Edmonds ROW construction permit Application --Page 3 of 3 Updated 3/25/2021
MINIMUM LANE CLOSURE TAPER LENGTH = L (NM)
µA
f1w
Posted Speed (mph)
]S
70
)5
a
4:
10
$5
60
1 66
1 ro
10
'05
15D
205
3T0
450
SWSW
tf
�f7
165
]2S
]S5
495
550
605
66O
t2
t:5
'SO
2i5
37C
�10
6CC
660
770
7(O
610
MINIMUM SHOULDER TAPER LENGTH = L13 (feet)
MOTH
(uEO
SHOULDERw.o.
Posted Speed (Mph)
-
+
a
56
60
65
70
S
90
12C
130
150
1so
fro
-V,
10
90
ISO
fro
190
IN
220
1,
USE A MINMW J DEVICES TAPER FOR SHOULDER LESS THEN F.
LEGEND
N
TEMPORARY SIGN LOCATION
•
TRAFFIC SAFETY DRUM
Cl>>
SEOUF.NTWL ARROW SIGN
®
TRANSPORTABLE ATTENUATOR
FP_CM_`S1
PORTABLE CMANGEABLE MESSAGE
x x
tt•
ROAD
WORK /\/\
AHEAD
68'
W20•I
®RIGHTLANE
11IMS11
1 SIGN SPACING — X (1) I
FREEWAYS A EXPRES5IVAY5 55 170 YPN I=,
RURAL ROMIS 6 t RHAN ARILMNIS » 130 MPH 200A (2)
RESIDENTIAL 6 BUSINESS DISTRICTS
URBAN SREETS 25 MIN OR LESS IOOA 921
(1)ALL $PACING MAY BE ADMIED 10 ACCOMMODATE INIEROLANGL
RAWS AT-ORAOF INTFRSFC-pNS AND DRIVFNMYS,
rA THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT
HOAWAY CONDITIONS
CHANNFII/ATION OFVICE
SPACING (lLctl
sc
60
20
AO
WARNING SIGNS SHALL BE
INSTALLED AT BOTH ENDS OF
THE WORK ZONE.
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
SPEED 00w,
27
)O
It 1
♦O
1 15
1 W
55
W
65
TO
LENGTH cf.*
15�
200
2Y) 1
304
1 360
1 U5
499
570
61S
730
TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE - R
HOST WNCIt Y.:I-....
450D 70 22.15D) 1>,.
1.OSf vt_HK::t'MIGHT
1 22 OX I..
< 15 MY•1
.1.55 MP'
S WII
< 45 1/➢11
A5-1 -
> 55 MPH
1-
ti?
•J2
7A
100 1
150
W3-4 RESUB
W20-4 W20-1 Jul 07 2021
1 CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
�_.
PCMS
x B •»
S T
4 y U 1 T WORK AREA / -
r, V R
LI s % x
RKi11T
IANE A MCAD
CLo6URE
SEE
NOTE 4
FRLO LOCATE I MILE 2IN
x I IS 4 f�e•A
ADVANCE OF "NE CLOSURE SIGNING.
IOWNER/CONTRACTOR RESPONSIBLE FOR LOCATING OWNER/CONTRACTOR IS RESPONSIBLE FOR
ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY EROSION CONTROL AND DRAINAGE
�- UTILITIES MAY REQUIRE A SEPERATE PERMIT.
WM2ll)
NOTES
ENGINEERING DIVISION
'. SEE SPECIAL PROVISIONS FOR WORK HOUR RESTRICTIONS.
Applicant shall repair/replace all
APPROVED AS NOTED
damage to utilities or frontage
2. EXTEND DEVICE TAPER AT Ln ACROSS SHOULDER.
improvements in City right-of-way
1IIp ��
per city standards that is caused or JF�� 07/30/2021
)' DEVICES SHALL HOT ENCROACH INTO THE ADJACENT LANE.
YY[•lt�ldhO4p
occurs during the permitted project. —Dr t�ctn
L USE IRANSVERSE DEVICES IN CLOSED LANE EVERY IOW(FT)
(RECOMMENOF.D;.
SINGLE CLOSURE FOR MULTI ROADWAYS
SPACING FOR THE Drn5NS7REAM TAPER SMALL BE
FFc
-LANE -LANE
7°o TN
6 ALL SIGNS ARE STACK ON ORANGE.
NO' 'O SGALL
666916
20312 92nd Ave W
Edmonds, WA 98020
Bore/Drill New UG = 58ft
Trench New UG =
New OH =
Overlash =
Existing UG =
Riser =
New Building Interior =
New Building Exterior=
TOTAL ROW FOOTAGE 58ft
COVER SHEET
CONTACTS:
Spectra Area Manager
Cole Ramirez (503)577-0501
Netvision Office Admin
Maribel Gonzalez (425)353-2078
e Contact
Freoy Munoz(425)314-8827
LEGEND
Tie in Point
Bore Path in Right of
Wa
—, New Flush Mount
L—J Carson
Asphalt/Concrete Cut
Comcast..
New Flus�hmount Carson
5x 10 Concrete Panel
Cut to expose bore
missile, water, power
5ft of 2inch Conduit Bore Path
infront of fire hydrant. We will
maintain 5ft horizontal seperation
from water main in road.
20312
ow
500 Concrete Panel
Cut to expose bore
92nd Ave W missile, water, power
5ft of 2inch Conduit Bore Path
TIE IN
POINT: infront offire hydrant. We will
PEDESTAL maintain a 5ft horizontal
seperation from water main in
r� road
5x12 cut to
expose bore
112
c'�. isile and
water
���[/r�,y Services
48ft of 2inch Conduit Bore Path
20308
`/ I F— F—
Soft DW
Vlore a new 11-anot nt arson box
48 t Bore
sH s<wr,+ton
Irom water mein
'TOTAL BORE PATH FOR
58' OF CONDUIT IN
RIGHT OF WAY.
.To
MAINTAIN 5 FEET
HORIZONTAL
CLEARANCE FROM
UTILITY
APPURTENANCES AND
FEET VERTICAL
CLEARANCE FROM ALL
SUBSTRUCTURE.
'ALL NEW
SUBSTRUCTURE TO HAVE
115n eoro
5.12 cut to
expose hore
missile and
water
services
DATE:
lBy.
REASON:
REVISION DESCRIPTIONS
� I
� �
REV.
Netvision Inc
DROP BURY
R
E S U
B
We will be installing a 2inch conduit to install Comcast service starting from the PED located next to house 20308. To
maintain the appropriate 5ft separation from water main in road, we will bore 5ft east to go under the sidewalk. Then
we will bore 48ft right going under along the sidewalk while maintaining a 5ft clearance from water main, then boring
J U L 21 2021
5ft west to place a new flush mount carson box at property line for house 20312. We will need a total of two cuts on the
the concrete sidwalk. One 5x10 cut to expose water, power, communications and the boring missile. The second cut will
be a 5x12 concrete panel cut to expose water services and the bore missile. We will maintain the appropriate clearance
for all utilities, Sft horizontal clearance from utility appurtenances and 2ft vertical clearance from all substructures. All
CITY OF EDMONDS
new substructure to have 36" cover.
DEVELOPMENT
TL
•@3127
r--
4
is Z
w
4w
ZZ
D 0 w O-F--
2
cn IL
w
wo-o
0
w "i --�
> LU
oj