A172.8-BF12 Series
BLD2021-0191 RECEIVED
Feb 02 2021
CITY OF EDMONDS
WATER COOLER/BOTTLE FILLER
BARRIER -FREE, WALL MOUNTED UNIVERSAL
BI-LEVEL ELECTRIC WATER COOLER WITH
-BF12 SENSOR OPERATED BOTTLE FILLER
STANDARD FEATURES
Electric Water Cooler
■ Child or Adult ADA Compliant (when properly installed)
■ All Metal, Granite Powder Coated Apron and One -Piece Bottom
Wrapper
■ Flexible, Low Flow, Antimicrobial, Anti -Rotation, Non -Squirt Bubbler
■ Auto -Stop allows Cartridge and Strainer service without removing cooler
deck to access water supply stop
■ Universal Bi-Level can be installed left high or right high with no
additional parts.
APPROVED
■ Lead Free
PLANS MUST BE
Bottle Filler ON JOB SITE
■ ADA Compliant
■ 100-Mesh Inlet Strainer ALL WORK SUBJECT
TO FIELD
■ 120VAC/9.OVDC Plug -In Transformer INSPECTION FOR
■ Laminar Flow Water Supply CODE COMPLIANCE
■ Hands -Free Sensor Operation
■ 1 GPM Fill Rate
■ 20 Seconds Maximum Run Time
SUGGESTED SPECIFICATIONS
Electric Water Cooler
Model A172108F is a Bi-Level, self-contained pressurized Water Cooler
that delivers a minimum of 8.0 GPH (30.3 LPH) of water at 50°F (10°C)
cooled from 80°F (26.7°C) inlet water and 90°F (32.2°C) ambient. Unit
shall be activated from an Antimicrobial Front Pushbutton using less than 5
pounds of force. Bubbler shall deliver a 0.3 GPM flow, have an
Antimicrobial Flexible Guard with an integrally designed non -squirt feature
and operate on a water pressure range of 20-105 PSIG. Basin shall be
constructed from 304 Stainless Steel and have an Integral Drain. Cabinet
shall be either Galvanized Steel with Granite Powder Coat or Stainless
Steel. Cooling system shall use R-134a refrigerant and be Capillary Tube
regulated. An Adjustable Thermostat with an "off' position shall regulate the
refrigeration system. Unit shall be listed by Underwriters Laboratories for
both the US and Canada and is compliant to the Air Conditioning and
Refrigeration Institute Standard 1010. Unit is certified to ANSI A117.1,
Public Law 111-380 (NO -LEAD), CHSC 116875 and NSF/ANSI 61, Section
9. Fixture meets ADA, ADA Standing Person, and ADA Child requirements
when mounted appropriately. Unit shall still deliver ambient water
temperature to the Bubbler in the absence of electrical power as long as
there is a pressurized water supply.
Bottle Filler
Bottle Filling unit shall include Sensor Operated activation with a 20 second
maximum run time. LED Lights illuminate the Bottle Fill area and brighten
when a bottle is detected. Housing construction will be 20 gage Stainless
Steel with a satin finish and will also include components manufactured
from Antimicrobial, impact resistant ABS. Optional -BCD (Bottle Counter
Display) indicates the quantity of 16 oz disposable Plastic Bottles saved
from a land fill and also displays when the Water Filter needs to be
replaced. Optional -WF1 has a 1500-gallon capacity, has NSF/ANSI 42 &
53 certification and reduces lead content in the drinking water by 99%.
Bottle Filler shall provide approximately 1 GPM flow rate with a Laminar
Flow Spout to minimize splashing.
MODEL:
(Must Specify)
FLEXIBLE BUBBLER
❑ A172108F-BF12
Granite Finish Cooler w/ Satin Finish
Bottle Filler
❑ A172408F-BF12
Satin Stainless Finish (Shown)
LEAD-FREE STAINLESS STEEL BUBBLER
❑ A172108S-BF12
Granite Finish Cooler w/ Satin Finish
Bottle Filler
❑ A172408S-BF12
Satin Stainless Finish
WATER COOLER OPTIONS
(additional costs may be incurred)
❑ -CSC3
Concealed Support Carrier
❑ -LOGO
Customer Specified Logo / Graphics
❑ -WF1
1500-gallon capacity, NSF 42+53,
1 micron Lead Reduction Filter
❑ -220V
220 volt 150 Hz compressor
BOTTLE FILLER OPTIONS
(additional costs may be incurred)
❑ -BCD Bottle Counter Display
Member of Wan.,
ter
U.S. Green Recyclable Co
BuildinProduct Product erving
QaCouncY
Complies GREEN
with the uPc .be.
,e
following ® 1-c�® Please visitwwwmurdockmfg.com
Standards: ® '-^ ) 11�5 for most current specifications.
NSF/ANSI 61 C
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Member of CJ
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com MORRIS GROUP
A172.8-BF12 New: 10123117
rL Muu -I
murdock®
SINCE 1853
WATER COOLER/BOTTLE FILLER
All dimensions are subject to manufactures tolerance of plus or minus %" nominal and subject to change without notice. Murdock Mfg. assumes no
responsibility for use of void or superseded data. Dimensions may change with the addition of optional accessories. Murdock Mfg.T", Member of Morris
Group International M. Please visit www.Murdockmfg.com for most current specifications.
37$"
[943]
1 74 -
1 [184]
[4 0]
44° 1 %"
[108] �-�� [473]
Optional -BCD Bottle 184,
Counter and Filter r[464]
Replacement Display
658" 65 �
[168] �� [168] f f�
*354' [15'2]
[895] 1 T--
*217,,
8
[556]
21
[57]
7„� T, 78 78 L — 1
[200] [200] 13 If *168
188" [133 [422]
[473] 1
3$"
[79]
24
[70]
19"
12$" [483]
[321 ]
13& 19$" [340] [492]
A172.8-BF12 Series
BARRIER FREE, WALL MOUNTED UNIVERSAL
BI-LEVEL ELECTRIC WATER COOLER WITH
-BF12 SENSOR OPERATED BOTTLE FILLER
IPIsiiiiiiiiiiim•7•�•�■
(Objects with leading edges
more than 27 inches and not I
■more than 80 inches above •
Ithe finished floor shall not
•project more than4 inches •
into the circulation path.
I1003.3.3 Horizontal
•projections 2018 IBC ■
di iiiiiiiiiiim • iiiiiiiiiiim • iiiiiiiiiiim • ■
Protruding objects shall not
Ireduce the minimum clear Is
■width of accessible routes.
I1003.3.4 Clear Width 2018 •
IBC
•Iri•�•II��•J
ALTERNATE MOUNTING
CONFIGURATION 1&
[ [[35]
6"
[152]
*33"
[838]
1 6„
12" [152]
[305] T-
1-1/4" [321 I/
P-TRAP BY l
OTHERS
V
General Notes: A. 3/8" O.D. Supply Inlet
1. All dimensions are in inches [MM] B. Waste Outlet for 1-1/4" P-Trap, by others
2. Allow 4 inches [1021MM] minimum clearance per side for ventilation C. Electrical Service Rough
*3. Dimensions shown are for ADA adult height. Adjust vertical dimensions as D. 03/8" Hanger Bracket Punching, 3 places
necessary to comply with Federal, State & Local Codes for Anchoring Hardware by others
4. Stop Valve, P-Trap & Electrical Outlet not supplied E. 01/4" Punching, 2 places for Anchoring
5. Important: Coolers must be attached to wall with appropriate Anchor Screws Hardware, by others
Murdock Mfg. TM warrants that its products are free from defects in material or workmanship under normal use and service for a period of 18
months from date of shipment. The sealed refrigeration system is warranted for five years. Murdock's liability under this warranty shall be
discharged solely by replacement or repair of defective material, provided MurdockTM is notified in writing within one year from date of
shipment, F.O.B. Industry, California.
All dimensions are subject to
Model Number & Options
Quantity
manufactures tolerance of plus or
minus M"nominal and subject to
change without notice. Murdock
Company
assumes no responsibility for use of
void or superseded data. Dimensions
. ,
may change with the addition of
Contact
Title
optional accessories. Murdock Mfg.T^'
Member of Morris Group
Signature
IntemationalTM. Please visit
(Approval for
www.murdockmfg.com for most
Manufacturing)
Date
current specifications.
MURDOCK MFG. • 15125 Proctor Avenue • City of Industry, CA 91746 USA Member of CJ
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com MORRIS GROUP
A172.8-BF12 New: 10123117