Loading...
BLD2021-0890+Architectural_Plan+6.25.2021_9.35.25_AM+2269361GENERAL REQUIREMENTS REFER TO SUBSEQUENT PLAN AND DETAIL NOTES FOR VARIATIONS AND REQUIREMENTS SPECIFIC TO REFERENCED PROJECT. NOTES ON DRAWINGS TAKE PRECEDENCE OVER GENERAL STRUCTURAL NOTES. DESIGN CRITERIA City Of Edmonds BUILDING CODE CONFORMANCE (MEETS OR EXCEEDS REQUIRE 1ENTS): Building Department Work FOUNDTION STABILIZATION 2018 INTERNATIONAL BUILDING CODE (IBC) 2018 INTERNATIONAL RESIDENTIAL CODE (IRC) 2018 WASHINGTON BUILDING CODE 2018 WASHINGTON RESIDENTIAL CODE DEAD LOADS: ROOF DEAD LOAD FLOOR DEAD LOAD WOOD WALL DEAD LOAD INTERIOR WALL DEAD LOAD CONCRETE LIVE LOADS: ROOF SNOW LOAD FLOOR LIVE LOAD (RESIDENTIAL) PUSH PIERS MATERIALS: BRACKET PLATES - ASTM A36 Address 9135 184TH ST SW Owner REISNER Approved Date 7 - 9 - 2 0 21 Building Official 15 PS BLD2021-0890 15 PS 12 PSF Special inspection required as 9 PSF identified under 150 PC Testing/Inspection section of plans. 25 PSF 40 PSF (MIN YI LDa�ds„ Fu = 58 KSI) PIER T DE B OR C (MIN YIELD STRESS, Fy = 50 KSI / MIN TENSILE STRESS, Fu = 55 KSI) EXTERNAL SLEEVE - ASTM A500 GRADE B (MIN YIELD STRESS, Fy = 50 KSI / MIN TENSILE STRESS, Fu = 62 KSI) PIER CAP - ASTM A529 GRADE 50 (MIN YIELD STRESS, Fy = 50 KSI / MIN TENSILE STRESS, Fu = 65 KSI) COIL ROD - ASTM A193 GRADE B7 (MIN YIELD STRESS, Fy = 105 KSI / MIN TENSILE STRESS, Fu = 125 KSI) STEEL ANGLE SHAPES - ASTM A36 (MIN YIELD STRESS, Fy = 36 KSI / MIN TENSILE STRESS, Fu = 58 KSI) WELDING NOTES: CONFORM TO AWS D1.1. WELDERS SHALL BE CERTIFIED IN ACCORDANCE WITH AWS REQUIREMENTS USE E70 ELECTRODES OF TYPE REQUIRED FOR MATERIALS TO BE WELDED. CORROSION PROTECTION: SACRIFICIAL DESIGN THICKNESS - CAPACITIES INCLUDE A SCHEDULED LOSS IN STEEL THICKNESS DUE TO CORROSION FOR BLACK, UNCOATED STEEL. ANCHORS ARE DESIGNED FOR 50-YEAR SCHEDULED SACRIFICIAL THICKNESS LOSS IN ACCORDANCE WITH ICC-ES AC358. INSTALLATION: SYSTEM TO BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS. MINIMUM INSTALLATION PRESSURE IS TO BE DETERMINED BY THE FOLLOWING EQUATION: PUSH PIER INSTALLATION PRESSURE (PSI): [DESIGN WORKING LOAD] X [FS = 2] / [HYDRAULIC RAM AREA] MINIMUM INSTALLATION DEPTH IS 10'-0" f UNO. NOTIFY ENGINEER IF MINIMUM INSTALLATION CONDITIONS CANNOT BE ACHIEVED. PUSH PIERS (CONT. EXISTING UTILITY LINES: CONTRACTOR TO REPAIR UTILITY LINES THAT MAY BE DAMAGED DURING INSTALLATION. PILES ARE TO BE GRAVITY SPLICED WITH FITTING COUPLERS. BUILDING WEIGHT WILL ENSURE JOINTS DO NOT SEPARATE. TESTING & INSPECTION IC� NTINLOU S SPECIAL INSPECTION IS REQUIRED DURING INSTALLATION PER 2018 IBC SI CTION 1810.4.12. TI E SPECIAL INSPECTOR IS RESPONSIBLE FOR VERIFYING AND RECORDING THE FOLLOWING: EXPIRES: 12/24/22 PROJECT DESCRIPTION (ADDRESS, INSTALLATION DATE, PERMIT NUMBER PILE AND BRACKET CONFIGURATION PART DESCRIPTION (PRODUCT MANUFACTURER, BRACKET TYPE, PIER TYPE, PIER OUTSIDE DIAMETER, PIER WALL THICKNESS) PIER INCLINATION, LOCATION, DEPTH, AND INSTALLATION PRESSURE ACHIEVED LL( AD TESTING SHALL BE PERFORMED IN ACCORDANCE WITH ASTM METHOD D1143 (QUICK METHOD) ON 20 PERCENT OF PIERS AND WILL BE SELECTED BY THE SPECIAL INSPECTOR. AN ALIGNMENT LOAD (AL) SHALL BE APPLIED TO THE PILE PRIOR TO SETTING THE DEFLECTION MEASURING EQUIPMENT TO ZERO OR A REFERENCE POSITION. THE AL SHALL BE NO MORE THAN 10% OF THE DESIGN LOAD. INCREMENTAL LOADING SHALL BE IN ACCORDANCE WITH THE FOLLOWING SCHEDULE. TEST LOADING SCHEDULE AL (.10 DL MAX) 0.25 DL 0.50 DL 0.75 DL 1.00 DL 1.25 DL 1.50 DL 1.25 DL 1.00 DL 0.75 DL 0.50 DL 0.25 DL HOLD TIME MAX DEFLECTION 0 MIN. UNTIL STABLE UNTIL STABLE UNTIL STABLE UNTIL STABLE UNTIL STABLE HOLD FOR CREEP TEST (SEE BELOW) 0.04 INCHES UNTIL STABLE UNTIL STABLE UNTIL STABLE UNTIL STABLE UNTIL STABLE LOAD TESTING CREEP ACCEPTANCE CRITERIA SHALL BE NO GREATER THAN 0.04 INCHES WITHIN A 10 MiNWTEa IOD. IF MOVEMENT IS OBSERVED GREATER THAN 0.04 INCHES WITHIN THE 10 MINUTE PERIOD THE LOAD TtSV 4T'1k,', T FOR AN ADDITIONAL 50 MINUTES, THE PIER IS TO BE DEEPENED AND RE -TESTED, OR THE PIER IS TO Q1E34WMI1@r>4ND WITH A NEW PIER. IF TEST TO BE HELD THE ,�4 30, REPLACED AND 60 MINUTES. THE HCREEP DVERSUS STHE LOGARITHM OF TIME SOHALLIEBESPLOT- I R6A 49 LESS THAN 0.080 INCHES BETWEEN 6 AND 60 MINUTES, THE LOAD TEST SHALL BE CONSIDERED SUCCESSFUL. PUSH PIER TEST PRESSURE (PSI): [DESIGN LOAD] X 1.5 / [AREA OF HYDRAULIC RAM]. DO NOT PLACE PIERS THIS ZONE W/O DIRECTIOP FROM ENGINEER \ / I z NO PIER PLACEMENT ZONE DO NOT PLACE PIERS THIS ZONE W/O DIRECTION FROM ENGINEER —CONTRACTOR TO NOTIFY FOR IF (E) FOUNDATION CRACK IS PRESENT IN THE SPAN BETWEEN FOUNDATION BRACKETS sfa 5FA Design Group, LLr rool P'im"d RORcIELivermore,fCA (Seattle, WA p: (503) 91.8311 w .fadg.o.m U z CE_ Z_ Q Z 0- Z W IL co N z z `n a) p Z)fnQ W = Q W 00 0 Q r Z _M cr 0) 0 p tr W LL W i- cn W W Q GENERAL NOTES [REVISIONS 1 PROJECT NO: MFR21-083 DESIGNED BY: MEK DRAWN BY: MEK CHECKED BY: CVR, JLD DATE: 06.18.2021 SHEET NO: S1.1 SCALE: NTS POLYLEVEL 400 HYDROPHOBIC FOAM POLYLEVEL 400 HYDROPHOBIC FOAM (CONT. MATERIAL PROPERTIES: INSTALLATION SEQUENCE VISCOSITY OF RESIN AT 77°F 350 CPS THE FOLLOWING INSTALLATION STEPS PROVIDE A BROAD OVERVIEW OF PL250H VISCOSITY OF ISOCYANATE AT 77°F 220 CPS AND PL400H INJECTION BENEATH A CONCRETE SLAB OR PAVEMENT. INTERMEDIATE LBS PER GALLON OF RESIN 9.17 LBS STEPS, INSTALLATION EQUIPMENT AND TOOLS USED, AND CONSIDERATIONS FOR LBS PER GALLON OF ISOCYANATE 10.2 LBS UNUSUAL CONDITIONS OR APPLICATIONS ARE NOT ADDRESSED. APPEARANCE OF RESIN (R-SIDE) CLEAR, YELLOW LIQUID APPEARANCE OF ISOCYANATE (A -SIDE) CLEAR, BROWN LIQUID SHELF LIFE OF SYSTEM 6 MONTHS MIX RATIO BY WEIGHT OF RESIN 91 PARTS BY WEIGHT OF ISOCYANATE 109 PARTS BY VOLUME OF RESIN 100 PARTS BY VOLUME OF ISOCYANATE 100 PARTS TYPICAL REACTION PROPERTIES CREAM TIME AT 77'F 8 TO 10 SECONDS CREAM TIME AT 100'F 4 TO 5 SECONDS RISE TIME AT 77'F 35 TO 40 SECONDS RISE TIME AT 100'F 20 TO 24 SECONDS TYPICAL PHYSICAL PROPERTIES DENSITY (ASTM D1622) 3.9 TO 4.1 PCF COMPRESSIVE STRENGTH (ASTM D1621) 62 TO 67 PSI TENSILE STRENGTH 250 TO 280 PSI POLYLEVEL EXPANDING FOAMS ARE MOST OFTEN USED BENEATH EXTERIOR CONCRETE SIDEWALK AND PAVEMENT SECTIONS FOR STABILIZATION OR RELEVELING, BUT ARE ALSO UTILIZED FOR INTERIOR WORK AND OTHER SPECIALTY APPLICATIONS. POLYLEVEL FOAM IS OFTEN CONSIDERED AS AN ALTERNATIVE TO MUDJACKING OR REMOVAL AND REPLACEMENT. SETTLEMENT OF RESIDENTIAL SLABS IS TYPICALLY THE RESULT OF CONSOLIDATION OF POORLY COMPACTED FILL SOILS AROUND FOUNDATIONS AND WITHIN UTILITY TRENCHES, SOFTENING OF WEAK NATIVE SOILS AND FILL DUE TO INCREASES IN MOISTURE CONTENT, AND EROSION OR WASHOUT CONDITIONS RESULTING FROM POOR DRAINAGE. CRACKED SLABS, FAULTING BETWEEN SLAB SECTIONS, AND/OR OTHER OBVIOUS DOWNWARD VERTICAL MOVEMENT ARE TYPICALLY THE FIRST OBSERVABLE SYMPTOMS OF SETTLEMENT FROM THE SURFACE, THOUGH VOIDS MAY ALSO BE PRESENT BELOW AS RIGID SLABS CAN SPAN BETWEEN SUPPORT POINTS. WHEN VOIDS ARE PRESENT, USING INERT, HYDROPHOBIC POLYLEVEL EXPANDING FOAM ALLOWS FOR UNDERSEALING OF THE REGION, PREVENTING ANY FURTHER WASHOUT AND ACTING TO AGAIN PROVIDE UNIFORM SUPPORT TO THE BRIDGED CONCRETE. WHEN SLABS HAVE SETTLED, WITH OR WITHOUT THE PRESENCE OF VOIDS, FOAM CAN BE INJECTED TO CREATE LIFT WITHOUT ADDING SIGNIFICANT WEIGHT TO THE UNDERLYING SOIL. POLYLEVEL FOAM IS INSTALLED WITH CUSTOM-BUILT INSTALLATION RIGS AVAILABLE AS TRUCK -MOUNTED OR TRAILER UNITS. THE BASIC COMPONENTS OF THE SYSTEM INCLUDE MATERIAL STORAGE TANKS, A GENERATOR, AN AIR COMPRESSOR, PUMPS, A PROPORTIONER, AND APPLICATOR(S)/ GUN(S). THE PROPORTIONER INCLUDES A MATERIAL HEATER, PRESSURE REGULATOR, STROKE COUNTER, AND INSULATED AND HEATED HOSES. THIS ENSURES THAT THE TWO PARTS ARE DELIVERED TO THE APPLICATOR AT A CONSISTENT PRESSURE AND TEMPERATURE. STEP 1: ACCESS/APPLICATION HOLES ARE DRILLED (%"0) AT STRATEGIC LOCATIONS IN THE SLAB. IN GENERAL, THE HOLES ARE SPACED 5 FEET APART AND 3 FEET FROM THE EDGES OF THE SLAB. LOCATIONS AND SPACING ARE OFTEN MODIFIED IN THE FIELD TO ACHIEVE THE DESIRED RESULT. STEP 2: INJECTION PORTS ARE PLACED TO SEAL THE HOLES. STEP 3: POLYLEVEL FOAM IS INJECTED TO FILL VOIDS AND ALLOW FOR LIFTING. LIFT WITH SURVEY EQUIPMENT OR STRING LINES. STEP 4: THE INJECTION PORTS ARE REMOVED AND THE HOLES ARE PATCHED WITH NEXUSPRO SILICONE JOINT SEALANT, OR EPDXY SEALANT. CRAWLSPACE STABILIZER INFO EXPIRES: 12/24/22 MAY BE MONITORED MORTAR MIX, SAFEBASE CRAWLSPACE STABILIZER SYSTEM INFO PART DESCRIPTION COMMENTS MIN YIELD STRESS, Fy MIN TENSILE STRESS, F. ASTM A500 GRADE C HD GALV, PER ASTM 123, TUBE HSS 31/2x31/2x11GAx'L' SQUARE TUBE 50 KSI 62 KSI THREADED ASTM A108 GRADE 1018 11/4"OxO'-7"L THREADED 54 KSI 64 KSI ROD ROD W/ WELDED HEAVY HEX NUT ASTM A500 GRADE C HD GALV, PER ASTM 123, HSS 4x4x3/16x2 36 KSI 58 KSI BASE PLATE ASTM A36 PL1/4x6xO'-6" 36 KSI 58 KSI LIGHTFOOT 3/16" HIGH DENSITY POLYETHYLENE SHELL (18"08" BASE) STABILIZER 10 PCF POLYURETHANE PRECAST IN PLASTIC FORM BASE 6 PCF POLYURETHANE IN 600 ML INJECTION TUBE SET LIGHTFOOT X 3/16" HIGH DENSITY POLYETHYLENE SHELL (24"x24" BASE) 1N3 w12iH S3QIAa3s 1N3w So NO VV CIA � 30 0�3A30 ATIO STABILIZER 15 PCF AND 10 PCF POLYURETHANE PRECAST IN PLASTIC FORM BASE 6 PCF POLYURETHANE IN 600 ML INJECTION TUBE SET LZOZ 8Z unf ASTM A36 R1/2x6xO'-6" WOOD BEAM 36 KSI 58 KSI TOP PLATE 1 "00 1/2" IPS SCHEDULE 40 PIPE CONDITION 35 KSI 60 KSI 1 11ox1 1/2" IPS SCHEDULE 40 PIPE STEEL BEAM 35 KSI 60 KSI TOP PLATE ASTM A500 GRADE C HD GALV, PER ASTM 123, HSS3x3x1/4x1'-O' CONDITION 50 KSI 65 KSI ASTM A500 GRADE C HD GALV, PER ASTM 123, HSS 4x4x3/16 36 KSI 58 KSI TOP CAP ASTM A36 PL3/4x4xO'-4" 50 KSI 65 KSI 11/4-7 HEAVY HEX NUT 1/4"-20x2" NUT & BOLT WITH (4) 10-16x3/4" SELF -DRILLING ATTACHMENT HARDWARE SCREWS W/ HEX WASHER HEAD NOTE: INSTALL PER MFR RECOMMENDATIONS sfa 5FA Design Group, LLr Portland R ORcI' Livermore,' CA I Seattle, WA p: (.) 91.83" w .fmg. . U Z ol: Z_ Q Z 0- Z W IL N z `- a) Z p Z) Cn Q Ly W � 0 Q p r Z _M cr CA 0 p fr W LL w Z W w cc Q GENERAL NOTES REVISIONS 1 PROJECT NO: MFR21-083 DESIGNED BY: MEK DRAWN BY: MEK CHECKED BY: CVR, JLD DATE: 06.18.2021 SHEET NO: S1.2 2'-0„ 0 I CV F�I E GARAGE CONC SLAB ON GRADE 1 S4.2 TYP N LE) DECK O LINE ABOVE - _ w er 7 g w a (g1 5-0»w c� 10 TYP �L6x6x%x3'—O" TYPE \ EXPIRES: 12/24/22 (E) FOUNDATION/(N) PIER LAYOUT PLAN NOTES: „ 1. REFERENCE S1.1 & S1.2 FOR GENERAL 6 -0 2 -0 REQUIREMENTS TYP o2. CONTRACTOR TO NOTIFY ENGINEER OF RECORD 16 17 18 Nf OF DISCREPANCIES BETWEEN FIELD CONDITIONS & _ 2 S4.31 THOSE SHOWN IN THESE DOCUMENTS PRIOR TO WORK TYP � r,. 11 12 94 I 1, % 13. INDICATES (E) CONC WALL ON (E) CONC ,,,��II :., of 0 FOOTING (CONTRACTOR TO VERIFY I o CD a_ I I o 0- I i� / 6"Wx2'-9"H (E) CONC WALL AND 2 S4.4 TYP 1 / 1'-0"Wx10"DP (E) CONC FOOTING MIN TYP / (NOTIFY ENGINEER OF RECORD IF FIELD o I o CONDITIONS DIFFER IN THE AREA OF I WORK)) 1 I I 4• INDICATES (N) CONC BACKFILL PER DETAIL Ii 1�,�II 1 S4.3 TYP - / 2/S4.2 & 2/S4.3 ((5) TOTAL) 24" SQ LIGHTFOOT XLLi 21 5• SECTION CUT - DETAIL NUMBER/SHEET NUMBER (E) CRAWL I I X/SX.X SPACE I STABILIZER BASE FTG I I (E) BEAM PER GENERAL NOTES ABOVE TYP 1 1 TYP I I I I,I II I:I I Ti I; IT I II I I II I ICI I<I 2 S4.3 �'�---- --- --- (E) FOUNDATION/ (N) PIER LAYOUT PLAN SCALE: 1/8"=1'-0" PLAN 6. (JR] INDICATES LOCATION OF SAFEBASE PUSH PIER W/ SAFEBASE-LD FOUNDATION BRACKET PER DETAILS ON 22 S4.1 ((25) TOTAL) PUSH PIER INSTALLATION NOTES: • MAX LOAD TO ANCHOR = 7,910 LBS • 2.875"0 PIPE PILE W/ 0.1875" THICK WALL • 3.5"Ox36" LONG PIPE SLEEVE W/ 0.220" WALL 23 • MINIMUM 10'-0" INSTALLATION DEPTH • MINIMUM 2000 PSI INSTAIWTI sPREAM3a • MINIMUM 1/4" FOUNDATION GV' 'A� �ALLATION 7. p INDICATES LOCATION OF SnIaAja U Q STABILIZER SYSTEM ((12) TOTAL EJ MAX LOAD TO JACK = 4,176 LBS 8. PIER SPACING SHALL BE AS INDICATED ON PLAN (7'-0" OC MAX) UNO 9. MAX UNSUPPORTED FOUNDATION SPAN SHALL BE 7'-2" ? % 10. CONTRACTOR TO NOTIFY ENGINEER OF RECORD IF (E) FOUNDATION CRACK IS PRESENT IN THE SPAN BETWEEN FOUNDATION BRACKETS 11. REPLACE "IN -KIND" ALL (E) WOOD MEMBERS (JOISTS, PURLINS, SUBPURLINS, SHEATHING, STUDS, WALL PLATES) WHICH SHOW SIGNS OF DRY ROT OR STRUCTURAL DAMAGE 12• ALL WOOD EXPOSED TO CONCRETE, WEATHER, OR WITHIN 6" OF FINISH GRADE SHALL BE PRESSURE -TREATED 13. CONTRACTOR SHALL NOT REMOVE ANY (E) POSTS OR PRE -CAST FOOTINGS SUPPORTING THE (E) FLOOR FRAMING 14. ALL CONSTRUCTION MATERIALS IN THESE DOCUMENTS ARE (N) UNO sfa SFA Design Group, LLL P..l .,`OR`I Live e• CAnI S,,Ul,, WA p:(503)91.8311 .—fMg.— CU Z Z_ Q z Z W IL (o N Z zoo p Z)fnQ w = Q w o0 p r Z LoO _M cr 0) 0 O fr w LL w Z W w Q (E) FOUNDATION/ (N) PIER/ LAYOUT PLAN [REVISIONS 1 PROJECT NO: MFR21-083 DESIGNED BY: MEK DRAWN BY: MEK CHECKED BY: CVR, JLD DATE: 06.18.2021 SHEET NO: S2.1 1 S4.1 OPP 7 0 HOLE �/HOLES/ TYP ---, Q 6 LINE OF SYMMETRY HOLE 234" 5 BEYOND ' 4 I 1 S4.1 SB-LD BRACKET - TOP 1" TYP '/8"0 HOLE TYP �—/R/PIPE/HOLES - EA SIDE OF R 3/16 1-2 4" 0xO.39"xO'-9" PIPE EA SIDE OF R 1 S4.1 LINE OF _ 1 SYMMETRY � 1�1 1�1 • ■ 1/16,10 I!I■�I�� BEYOND U NOTES: REF 1 /S4.1 FOR MATERIALS LIST SB-LD BRACKET - FRONT SCALE: 1 1/2"=1'-0" M SAFEBASE-SD FOUNDATION BRACKET MATERIALS LIST ITEM # PART DESCRIPTION DIMENSIONS GRADE 1 MAIN R 04x5x0'-93/4" A36 2 SEAT R R1/010x0'-10" A36 3 BACK R V/4x7x0'-10" A36 4 TOP R R3/4x31/2x0'-81/2" A36 5 STRAP BENT f 3%x3x2'-0" A36 6 MAIN TUBE* HSS 31/2"00.1880'-9" A500 7 ALL THREADED RODS (2x) 3/4"0x1'-0" A193 8 THREADED HEX NUTS (4x) - A194 9 PUSH PIER SHAFT* PIPE 2.875"0xO.188x4'-0" A500 10 PUSH PIER EXTERNAL SLEEVE** PIPE 3.50"0xO.22Ox3'-0" A500 11 FRICTION REDUCER** PIPE 3"00.1880'-1" A53 * DIMENSIONS GIVEN AS OUTER DIAMETER x WALL THICKNESS x LENGTH ** ITEMS NOT SHOWN FOR CLARITY mt.] NOTES: REF 1 /S4.1 FOR MATERIALS LIST SB-LD BRACKET - SIDE SCALE: 11/2"=1'-0" EXPIRES: 12/24/22 SCALE: 11/2"=1'-0" 1 S4.1 (D LINE OF CV\1\/CTOV N 34 �0-13A3c ITIO NOTES: REF 1 /S4.1 FOR MATERIALS LIST SB-LD BRACKET - BACK SCALE: 11/2"=1'-0" sfa SFA Design Group, LLE Portland' oI II Livermore, CA n Seattle, WA I p:1503)W4311 www.sladg.wm U z ol: Z_ Q Z 0- Z W Cc N z zZ pcnQ C-cy) 0 W = Q Z Lu t U) r p Z co 0 c 0 W LL cr w W w tr Q BRACKET DETAILS REVISIONS PROJECT NO: MFR21-083 DESIGNED BY: MEK DRAWN BY: MEK CHECKED BY: CVR, JLD DATE: 06.18.2021 SHEET NO: S4.1 (E) WALL SHEATHING (E) EXTERIOR SURFACES (SAWCUT AS REQ'D) ((E) EXTERIOR GRADE AS OCCURS) DIRECT INJECTION - POLYURETHANE PER PLAN (E) WALL FRAMING (E) CONC STEMWALL (E) CONC FOOTING (CHIP FLUSH W/ STEMWALL AS REQ'D) FOUNDATION BRACKET PER PLAN SAFEBASE PUSH PIER & EXTERNAL SLEEVE PER PLAN NOTE: REF PLAN FOR LAYOUT & INSTALLATION REQ'S (N) PUSH PIER TO (E) FOUNDATION DETAIL SCALE: 1 "=1'-0" (E) WALL SHEATHING (E) EXTERIOR SURFACES (SAWCUT AS REQ'D) ((E) EXTERIOR GRADE AS OCCURS) DIRECT INJECTION POLYURETHANE PER PLAN 0 I N 14 d .a ° °< a., ° I,°� °. a. a a 0 4 �a d v I. a d' 1'-6" 0 (E) WALL FRAMING EXPIRES: 12/24/22 (E) CONC STEMWALL (E) CONC FOOTING (CHIP FLUSH W/ STEMWALL AS REQ'D) T:F—FOUNDATION BRACKET PER PLAN 1N3 W12iVd 34 S301A� J-DS 1N3Wd0�3/�3O SONOWO3 =10 ATI0 Lzoz 8Z unf GaAlBOBU CONCRETE BACKFILL CENTERED ON PIER TUBE INSTALLED FLUSH W/ FOUNDATION BRACKET (f'c=2500 PSI MIN) SAFEBASE PUSH PIER & EXTERNAL NOTE: SLEEVE PER PLAN REF PLAN FOR LAYOUT & INSTALLATION REQ'S (N) PUSH PIER TO (E) FOUNDATION DETAIL SCALE: 1 "=1 '-0" sfa SFA Design Group, LLE x p. (563J 641 8311 www. hdq com U Z CE_ Z_ Q Z 0— Z W Im N Z 0 Z Z)Una co `n a) p W = Q Q III 0 r-- p Z Y J _-- p cr fr 0) 0 w LL w i- cn W w cc Q PIER DETAILS [REVISIONS 1 PROJECT NO: MFR21-083 DESIGNED BY: MEK DRAWN BY: MEK CHECKED BY: CVR, JLD DATE: 06.18.2021 SHEET NO: S4.2 (E) WALL SHEATHING N I ,--(E) WALL FRAMING (E) FLOOR SHEATHING (E) EXTERIOR SURFACES (SAWCUT AS REQ'D) ((E) EXTERIOR L(E) FLOOR FRAMING GRADE AS OCCURS) (PARALLEL AS OCCURS) e a (E) CONC STEMWALL ° o (E) INTERIOR GRADE II-1II-1 DIRECT INJECTION -1 I —I POLYURETHANE PER PLAN — 1 - FOUNDATION BRACKET PER PLAN SAFEBASE PUSH PIER & EXTERNAL SLEEVE PER PLAN NOTE: REF PLAN FOR LAYOUT & INSTALLATION REQ'S (N) PUSH PIER TO (E) FOUNDATION DETAIL SCALE: 1 "=1'—O" (E) WALL SHEATHING (E) EXTERIOR SURFACES (SAWCUT AS REQ'D) ((E) EXTERIOR GRADE AS OCCURS) DIRECT INJECTION POLYURETHANE PER PLAN 0 I N 1'-6" O (E) WALL FRAMING (E) FLOOR SHEATHING EXPIRES: 12/24/22 (E) FLOOR FRAMING (PARALLEL AS OCCURS) (E) CONC STEMWALL (E) INTERIOR GRADE a —I11=III—III —I I (E) CONC FOOTING 1— (CHIP FLUSH W/ STEMWALL AS REQ'D) SAFEBASE PUSH PIER & EXTERNAL NOTE: SLEEVE PER PLAN REF PLAN FOR LAYOUT & INSTALLATION REQ'S (N) PUSH PIER TO (E) FOUNDATION DETAIL SCALE: 1 "=1 '—O" sfa SFA Design Group, LLE poola�a�oI L —m����A x p. (-) 641 8311 www. hdq com U z CE_ z Q Z � Z W Im N z 0 Z Z)Una co `- a) p W = Q Q W 00 0 r p z Lop _-- cr 0) 0 w LL w Z W w cc Q PIER DETAILS REVISIONS PROJECT NO: MFR21-083 DESIGNED BY: MEK DRAWN BY: MEK CHECKED BY: CVR, JLD DATE: 06.18.2021 SHEET NO: S4.3 (E) EXTERIOR SURFACES (SAWCUT AS REQ'D) ((E) EXTERIOR GRADE AS OCCURS) DIRECT INJECTION POLYURETHANE PER PLAN (E) CHIMNEY (E) CONC CHIMNEY FOOTING (CHIP FLUSH AS REQ'D) IIIj11I I STEEL ANGLE PER PLAN (AS OCCURS) -FOUNDATION BRACKET PER PLAN SAFEBASE PUSH PIER & EXTERNAL SLEEVE PER PLAN NOTE: REF PLAN FOR LAYOUT & INSTALLATION REQ'S (N) PUSH PIER TO (E) CHIMNEY DETAIL SCALE: 1 "=1'-O" EXPIRES: 12/24/22 (E) FLOOR SHEATHING \-- (E) FLOOR FRAMING TYP 4 (E) FLOOR BEAM (41/2"W MIN) ALL -THREAD ROD PER GENERAL NOTES (0'-3" MAX UNBRACED THREADED ROD LENGTH) TOP PLATE PER • GENERAL NOTES W/ (4) :::::::)STABILIZER #12x3" WOOD SCREWS THREADED POST CAP PER GENERAL NOTES TUBE PER GENERAL NOTES (CUT TO REQ'D LENGTH) BASE PLATE PER GENERAL NOTES (E) INTERIOR GRADE LIGHTFOOT XL STABILIZER BASE PER GENERAL NOTES — — =b=azlo n (' NOTES: 1. REF PLAN FOR LAYOUT & INSTALLATION REQ'S 2. INSTALL PER MFR RECOMMENDATIONS SAFEBASE CRAWLSPACE STABILIZER SCALE: 1 "=1'-0" 3au sfa SFA Design Group, LLE x p. (563J 641 8311 www. hdq com U z CE_ Z_ Q Z � Z W w N z zoo Z)v)a p W = Q Q W co 0 r p Z _-- cr 0) 0 w LL w i- cn W w > cc F-' Q PIER DETAILS [REVISIONS 1 PROJECT NO: MFR21-083 DESIGNED BY: MEK DRAWN BY: MEK CHECKED BY: CVR, JLD DATE: 06.18.2021 SHEET NO: S4.4