Loading...
BLD2021-0847+Architectural_or_Building_Floor_Plans+6.14.2021_10.44.44_AM+2247694DR. SCOTT BABIN, DDS DENTAL OFFICE TENANT IMPROVEMENT EDMONDS, WASHINGTON VICINITY: LEGAL DESCRIPTION: WILLOWDALE GARDENS DIV 1 BLK 000 D-01 — LOT 17 LESS N 250FT PHASE OF WORK: EXIT — — PHASE I F [�] WALL TYPES: I =F]F] 1 I I EXISTING WALLS TO REMAIN I � I O NEW INTERIOR WALLS -- 5/8" G.W.B. CPT-1 OVER 3-5/8" METAL STUDS ® 24" I I O.C.; PACKED WITH SOUND BATT INSULATION; SMOOTH FINISH G.W.B. La W/ MTL. CORNERS, U.N.O. I CPT-1 ; 01 I 1 I 1 LVT-1 — I CPT-4 / \ F— � (E) CIT (E) E.LL / n LVT-1 1 w/D L 1' (E) LVT 1 1 1 (E) CPT EXIT EGRESS = 75'-0" 1 1 (E) LVT (E) LVT (E) LVT 1 1 vT-1 1 1 O O 1 SCALE: u. (E) &PT -/ 0 2' 4' 8' 3/16"= V-0" RELEASE OF DRAWINGS: I HAVE REVIEWED ALL OF THE DRAWINGS PREPARED BY THE ARCHITECT/DESIGNER, UNDERSTAND THEM FULLY, AND AUTHORIZE THEIR RELEASE FOR PERMITTING, CONTRACTOR BIDDING AND CONSTRUCTION. I UNDERSTAND THAT ANY CHANGES AND/OR ADDITIONS TO THE PLANS COULD RESULT IN CHANGE ORDERS AND/OR ADDITIONAL COST BEYOND THE SCOPE OF THESE DRAWINGS. CLIENT: 12' APPLICABLE CODES: (CODES WITH STATE AND LOCAL AMENDMENTS): • 2018 INTERNATIONAL BUILDING CODE AS AMENDED BY THE STATE OF WASHINGTON AND THE CITY OF EDMONDS • 2018 INTERNATIONAL EXISTING BUILDING CODE AS AMENDED BY THE STATE OF WASHINGTON AND THE CITY OF EDMONDS • 2018 INTERNATIONAL FIRE CODE AS AMENDED BY THE STATE OF WASHINGTON AND THE CITY OF EDMONDS • 2018 INTERNATIONAL MECHANICAL CODE AS AMENDED BY THE STATE OF WASHINGTON AND THE CITY OF EDMONDS • 2018 WASHINGTON STATE ENERGY CODE — COMMERCIAL PROVISIONS • 2009 ICC A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES • 2020 NATIONAL ELECTRICAL CODE SECTION (NEC) AND 2020 WASHINGTON CITIES ELECTRICAL CODE SECTIONS AS AMENDED BY THE CITY OF EDMONDS • 2018 UNIFORM PLUMBING CODE (UPC) AS AMENDED BY THE STATE OF WASHINGTON AND THE CITY OF EDMONDS GENERAL CONSTRUCTION NOTES: 1. A SEPARATE PERMIT IS REQUIRED FOR THE MECHANICAL, ELECTRICAL, AND PLUMBING OF THIS TENANT IMPROVEMENT. FIRE PROTECTION (IF APPLICABLE) IS SEPARATE PERMIT. 2. ALL WALL PARTITIONS TO BE DEMOLISHED ARE NON —BEARING. 3. PROVIDE ONE 2A10BC PORTABLE FIRE EXTINGUISHER PER NFPA-10 FOR EVERY 3,000 S.F. OF AREA AND NOT TO EXCEED 75 FT. OF TRAVEL DISTANCE BETWEEN EXTINGUISHERS. VERIFY LOCATION WITH FIRE MARSHAL. 4. SUBCONTRACTOR IS TO BRING TO ATTENTION TO THE CONTRACTOR ANY DISCREPANCIES ON DRAWINGS DURING BID PROCESS. 5. CONTRACTOR TO CONDUCT A DENTAL EQUIPMENT LAYOUT MEETING WITH DENTAL SUPPLIER AND SUBCONTRACTORS. - MECHANICAL HVAC, ELECTRICAL AND PLUMBING TO BE MODIFIED UNDER SEPARATE PERMIT. - VACUUM / AIR AND MED GAS TO BE UNDER PLUMBING PERMIT (3RD PARTY VERIFICATION REQUIRED). - BOTTLED WATER @ OPS. - NO CHANGE OF OCCUPANCY USE. - NO STRUCTURAL MODIFICATIONS TO BUILDING EXTERIOR. SHEET INDEX: ID-1 COVER SHEET / SITE PLAN / CODE ANALYSIS PLAN / PROJECT NOTES ID-2 PARTITION FLOOR PLAN ID-3 REFLECTED CEILING PLAN ID-4 FINISH PLAN & CASEWORK DETAILS ID-5 PLUMBING & ELECTRICAL PLAN ID-6 DETAILS ID-7 INTERIOR ELEVATIONS PROJECT DESCRIPTION: DENTAL OFFICE TENANT IMPROVEMENT: OCCUPIED REMODEL OF EXISTING 1,547 SQ. FT SPACE IN EXISTING 1—STORY OFFICE BUILDING. NO STRUCTURAL CHANGES, NO CHANGE OF USE. INTERIOR WALLS, DOORS, CABINETS, REPLACEMENT OF CEILING TILE. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHTING FIXTURES PER PLANS. ESTIMATED CONSTRUCTION VALUE: $65,000.00. PROJECT ADDRESS: 7631 212TH ST SW, SUITE 109—C EDMONDS, WA 98026 CONTACTS: BUILDING OWNER: OASIS, INC. 1516 129TH AVE NE WOODINVILLE, WA 98072 CONTACT: SAM ABOULHOSON PHONE: (425) 486-0566 EMAIL: SAMIR—ABOULHOSON@YAHOO.COM ItNd\IA\ha DR. SCOTT BABIN, DDS 7631 212TH ST SW, SUITE 109—C EDMONDS, WA 98026 PHONE: (206) 972-4962 EMAIL: INFO@SCOTTBABINDDS.COM INTERIOR DESIGNER: DAVID COMPANY CONTACT: KELLY NEWBOLD PHONE: (206) 999-3457 GENERAL CONTRACTOR: DAVID COMPANY CONTACT: KELLY NEWBOLD PHONE: (206) 999-3457 DENTAL EQUIPMENT SUPPLIER: TO BE DETERMINED ADMINISTRATIVE: BLDG. ID: 1 OF 1; TAX PARCEL NO.: 00614300001701 ZONING JURISDICTION: CITY OF EDMONDS ZONING CLASSIFICATION: BN (NEIGHBORHOOD BUSINESS) PARKING SPACES: NO CHANGE OCCUPANCY USE: NO CHANGE BUILDING: NUMBER OF STORIES: 1 BUILDING TYPE OF CONSTRUCTION: V—B, (NON—SPRINKLERED/NO FIRE ALARM) TENANT SPACE: PROJECT AREA FOR THIS TENANT IMPROVEMENT: 1,547 S.F. OCCUPANCY GROUP: GROUP B (DENTAL OFFICE) OCCUPANT LOAD: 1,547 S.F / 150 S.F. = 10.31 = 11 OCCUPANTS (ONLY 1 EXIT REQUIRED) MAX. NUMBER OF EMPLOYEES/MANAGERS WORKING AT SAME TIME: 5 David Company CLIENT / PROJECT: Scott A. Babin, DDS and Associates JOB ADDRESS: Edmonds Office 7631 212th St SW, STE 109C Edmonds, WA 98026 APPROVAL: Stage Completed: Signature: Date: CONSTRUCTION SET COVER SHEET ISSUE: DATE: REVISIONS: DATE: Drawn By: Checked By: This drawing is the exclusive property of the Architect/Designer and may not be reproduced in part or whole without prior written permission. ID-1 DATE: ---- / ---- / Project No.: 14-72 Date: 5/22/2021 28'-1" 13'-7" 12'-10" 14'-6" GENERAL PLAN NOTES: PHASE OF WORK: — — PHASE WALL TYPES: L--------J EXISTING WALLS TO BE DEMOLISHED EXISTING WALLS TO REMAIN NEW INTERIOR WALLS -- 5/8" G.W.B. OVER 3-5/8" METAL STUDS © 24" O.C.; PACKED WITH SOUND BATT INSULATION; SMOOTH FINISH G.W.B. W/ MTL. CORNERS, U.N.O. DEMO COUNTER AND - BASE CABINETS. CUT COUNTERTOP AND BACKSPLASH BACK 30". PLAM EDGE OF COUNTERTOP AND BACKSPLASH. PLAM BASE CABINET. CABINET PER PLAM SCHEDULE. SAVE EXISTING 4-PLEX OUTLET DEMO WIRE PLUG MOLD I r� EXISTING WAITING I J i i II i i i RECEPTION 113 CASEWORK RELOCATED CPT-1 PER PLAN RECEPTION i i i i TV ID-7 112 C I I ( r==� I I I 1 II . II I 1 __ J L_� F _ Lj �� ==j1J 1 O PT-1 i --------- 11 II O „ j I Q i i i i DEMO FLOOR 1 1 1 1 ST AIR RETURN. I � 1 14'- 0"HCOU TER _ ID-7 LVT29" 3'-01 REF'R. 'tt1P -� 1 2oX� DVK T--------- - --- ---- - �\11�� (E) CPT2----- - -- ---- - i O OFFICE (EB I�E) IFT CAL i II 108 LA RES ROOM STERIL 109 i'�, iT ID-7 102 101 110 1 I ao ( 4 I 1 T (�) LV / 0 - ,--r. ---- W/D I i \- % (E) LVT __ DEMO ( ) �ARPET 1 ___�� N O O --& WALZ BASE r — _----------- 1—J------J 00 5, » 11'-7" 4'-6" 9' 3'— 6 2'— 2 (E) CPT It 1 3 —1 Ott 3'— 6 1 —6 1 —9 2 —11 HD i (E) CPT is, r—-------- --- — - -- IS1 w l --- --L ----- (E) LVT (E) LVT (E) ILVT__'-* T 1 i ' F (( ( LL�JJI /-- - OP.5 OPE 4 OPE 3 HYG) i i HYG 1 103 O 104 O 105 106 --1- J 107 I i i i i NON-FUNCTIONAL DOOR 9'-7" 9'-6" 9'-6" 9'-6" 9'-6" FLOOR PLAN SCALE: 1 /4"=1'-0" IRELOCATE RETURN IN I(E) WALL, SEE ID-5 I I PANO VIEWING WINDOW, 24"X 14" X 1 /2" GLASS LO 0 NON-FUNCTIONAL DOOR 0 2' 4' 8' 12' 1 /4"= 1'-0" DOOR SCHEDULE: DOOR SCHEDULE NOTES: DOOR DOOR FRAME NO. REMARKS 1. SEE FINISH SCHEDULE FOR DOOR FINISH SPECIFICATIONS. 2. PROVIDE (3) DOOR SILENCERS FOR EACH INTERIOR SWINGING DOOR TYPE WIDTH HEIGHT THICK MAT. FINISH GLAZ'G RATING HDWR TYPES MAT'L FINISH OE EXISTING DOORS (IVES SR64 OR SR65). 3. PROVIDE STANDARD WEIGHT COMMERCIAL DOOR HINGES. Ol A 3'-0" 7'-0" 1 3/8 S.C. WD ST-1 T.P./D.G. N.R. D S.C. WD ST-1 NEW POCKET DOOR - MATCH EXISTING STAIN 4. ALL DOORS W/ CLOSERS TO HAVE BALL BEARING HINGES. 5. PROVIDE DOOR STOPS AT APPROPRIATE LOCATIONS. 6. DOOR HARDWARE TO MEET WAC-51-20 BARRIER -FREE CODE (LEVER STYLE HANDLES). MAXIMUM DOOR OPENING PRESSURES ARE LIMITED TO 8.5 LBS. AT EXTERIOR DOORS AND 5.0 LBS AT INTERIOR DOORS. 7. EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE O A 3'-0" 7'-0'$ 1 3/8 S.C. WD ST-1 T.P./D.G. N.R. D S.C. WD ST-1 (E) POCKET DOOR RELOCATED FROM DR'S OFFICE O A S-O" 7'-0" 1 3/8 S.C. WD ST-1 T.P./D.G. N.R. D S.C. WD ST-1 (E) POCKET DOOR RELOCATED FROM HYG. 1 OF KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 8. HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES ON DOORS, CABINETS, PLUMBING FIXTURES AND STORAGE FACILITIES SHALL HAVE A LEVER OR OTHER SHAPES WHICH WILL PERMIT OPERATION BY WRIST OR ARM PRESSURE AND WHICH DOES NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING TO OPERATE. 9. CHECK LEAD TIMES AS SOME PRODUCT MAY HAVE LONGER LEAD TIME. 10. ALTERNATE MANUFACTURER'S MAY BE SELECTED WITH DESIGNER'S APPROVAL. 11. DOOR THRESHOLD SHALL NOT EXCEED 1 /2" IN HEIGHT. DOOR HDWR TYPES: A SECURITY LOCK - SCHLAGE AL SERIES, LEVER STYLE #17 IN SATIN CHROME, VERIFY TO MATCH EXISTING HARDWARE B PASSAGE - SCHLAGE AL SERIES, LEVER TO MATCH EXISTING HARDWARE C PRIVACY - SCHLAGE AL SERIES, LEVER STYLE #17 IN SATIN CHROME, VERIFY TO MATCH EXISTING HARDWARE D POCKET DOOR PULL - TRIMCO 1069-619 SERIES SLIDING DOOR PULL IN SATIN NICKEL. NOTE: SEE TYPICAL FLOOR TRANSITIONS DETAIL FOR THRESHOLDS E BI-FOLD DOOR PULL - 4" WIRE PULL IN SATIN CHROME. ABBREVIATIONS: (E) EXISTING H.M. HOLLOW METAL F SOUND/LIGHT GASKET - PEMKO PE319CN 3/16" SPONGE NEOPRENE D.G. DECORATIVE GLAZING SEAL FOR 3'x 7' DOOR W/ DRAFT SWEEP T.P. TEMPERED PLATE G DOOR CLOSER (PUSH SIDE) - SARGENT 351-PH9-26D (SATIN CHROME) PT-# PAINT H DOOR CLOSER (PULL SIDE) - SARGENT 351-H-26D (SATIN CHROME) S.C. WD SOLID CORE WOOD ST-# STAIN F.R.G. FIRE -RATED GLAZING ("FIRELITE") J WALL BUMPER DOOR STOP - IVES WS404 (SATIN CHROME) K FLOOR DOOR STOP - IVES FS436 DOME STOP (SATIN CHROME) N.R. NON -RATED L SMOKE/DRAFT GASKET - PROVIDE SMOKE & DRAFT GASKETING PER FIRE CODE. WALL TYPES: 1. ALL DIMENSIONS FROM FACE OF FINISH TO FACE OF FINISH, UNLESS NOTED OTHERWISE (U.N.O.). CONTRACTOR TO VERIFY DIMENSIONS AND BRING TO DESIGNER'S ATTENTION ANY CONFLICTS BETWEEN PROPOSED LAYOUT AND ACTUAL FIELD CONDITIONS BEFORE FRAMING OR PLUMBING WORK BEGINS. 2. IN -WALL BRACKETS FOR COUNTERTOPS TO BE SUPPLIED AND LOCATED BY CABINET MAKER, INSTALLED BY GC. 3. PROVIDE U-BREAK SHAPED ALUMINUM END WALL CAPS WHERE WALLS MEET STOREFRONT WINDOWS W/ 1" LEG, COLOR TO MATCH EXISTING STOREFRONT FRAMES. 4. PATCH AND REPAIR EXISTING DRYWALL AT DEMO AFFECTED AREAS. 5. REMOVE EXISTING WALLS & DOORS AS NOTED ON PLAN. DEMO NOTES: 1. REMOVE ALL EXISTING CARPET AND BASE PER PLANS. 2. REMOVE ALL EXISTING LIGHT FIXTURES PER PLANS. 3. REMOVE EXISTING CABINETS, DOORS, DOOR FRAMES AND GLASS PER PLANS. EXISTING WALLS TO REMAIN L--------J EXISTING WALLS AND ITEMS TO BE DEMOLISHED NEW INTERIOR WALLS -- 5/8" G.W.B. EA SIDE OVER 3-5/8" METAL STUDS @ 24" O.C.; SMOOTH FINISH G.W.B. W/ MTL. CORNERS, U.N.O. SYMBOLS LEGEND: F.E.C. SEMI -RECESSED FIRE EXTINGUISHER CABINET, "JL INDUSTRIES" 7*7 AMBASSADOR #CADA1816F10, W/ CLEAR ACRYLIC DOOR. MOUNT W/ BOTTOM LEADING EDGE 27" MAX A.F.F., PAINT TO MATCH WALL COLOR. WAITING ROOM NAME & NUMBER Ol O DOOR NUMBER ID-7 7 INTERIOR ELEVATION SYMBOL (INSIDE = SHEET; OUTSIDE = ELEVATION NUMBER) DOOR TYPES: -SOLID CORE WOOD DOOR W/ WOOD FRAME SEE SCHED. 2'- 0„ —------- � I I I TEMPERED GLASS I w I J I � I Cn p I w I 2 I U I w I N I I I i I i o I I S.C. WOOD POCKET DOOR V, David Company CLIENT / PROJECT: Scott A. Babin, DDS and Associates JOB ADDRESS: Edmonds Office 7631 212th St SW, STE 109C Edmonds, WA 98026 APPROVAL: Stage Completed: Signature: Date: CONSTRUCTION SET PARTITION PLAN ISSUE: DATE: REVISIONS: DATE: Drawn By: Checked By: This drawing is the exclusive property of the Architect/Designer and may not be reproduced in part or whole without prior written permission. I D�2 Project No.: 14-72 Date: 5/22/2021 PHASE OF WORK: PHASE WALL TYPES: r-------- EXISTING WALLS TO BE DEMOLISHED L--------J EXISTING WALLS TO REMAIN ®X5 010 II II X5 II II II IL-r ---------______- --L-______L------_ X X X / 1 DEMO LIGHTING, — TYP ------T-------- -----T� I r--- -----� I LL. I II II II I II II II II II II II II II II II II I I I I I I I I I II II I I I I I I I II�II I I I I I I II%<II I I I I I j L— J L— r--- J LJ I I II II I II II ------------- --------� Lr----------� --�1----------� DEMO HEADER DEMO SOFFIT AND CAN LIGHTING 71 — — — — — — — — — — — — — — — — — - 1 1 DEMO SOFFIT AND SALVAGE CAN LIGHTING H 1 X2 i i+�+� 7�-�X5 IL-�X5 I I I I �4 / J �---------�-1 '.L"XS J ®X5 ®X5 ® H ®X5 II _- _______ LL_______ ------1-----------------1 r1------L--------- II II I I DEMOLITION REFLECTED CEILING PLAN SCALE: 1 /4"=1'-0" PHASE 1 WALL TYPES: EXISTING WALLS TO REMAIN NEW INTERIOR WALLS -- 5/8" G.W.B. OVER 3-5/8" METAL STUDS @ 24" O.C.; PACKED WITH SOUND BATT INSULATION; SMOOTH FINISH G.W.B. W/ MTL. CORNERS, U.N.O. W/D r 0 X \ LAB RESTRO®X5 102 F101 / 0 103 J ®X5 0 0 2' 4' 8' 12' 1 /4"= 1'-0" I I A WAITING ®K G G 113 04 EXISTING GWB CEILING A + 8'-0" AFF R12'-11 3/4" RECEPTION I 112 --/ 04 I STAFF A 12'-2" 111 NEW GWB SOFFIT _ ®X5 + 7'-0" AFF Ox17 / \ — — — — — — — — — — — — — — — ®X5 OFFICE H® 108 A X2 SURGICAL OP.6 109 I^ J @)MISTING GWB CEILING ®XSEXISTING GWB SOFFIT ®X5 + 8'-0" AFF ® H ®X5 rn�) LIGHTING FIXTURE SCHEDULE: 'LL DEMO EXISTING SURFACE MOUNTED 1' X 4' FLORESCENT X1 �i -----J LIGHT FIXTURES <120W>. X2 ii X2 ii EXISTING/RELOCATED 2' X 4' TROFFER. <84W> I I LL------- JJ 1 'lX3 DEMO EXISTING RECESSED CAN LIGHTS. <40W> �'X4 �' X4 EXISTING/RELOCATED RECESSED LED CAN LIGHTS. <11.7W> '+; EXISTING/RELOCATED SURFACE MOUNTED LIGHTS. <36W> X5 �L-/X5 X6 DEMO EXISTING RESTROOM VANITY LIGHTS. <180W> NEW 2' X 4' LED SURFACE MOUNTED FIXTURES PER A PLAN: "LITHONIA BLTX4-30L-ADP-EZ1-LP935 - 3500 KELVIN". <48W> NEW UNDER CABINET LED LIGHTS: "TECH LIGHTING UNILUME LED SLIMLINE 700-UCF-XX-8-2-W-LED", FINISH: WHITE. LENGTHS WILL VARY (7", 13", 19", 30"), SEE CABINET ELEVATIONS. BUTT FIXTURES TOGETHER AND G MOUNT DIRECTLY BEHIND VALENCE WITH DIFFUSER FACING WALL. ELECTRICIAN TO PROVIDE CONDUIT TO EACH LIGHT BANK. LOW PROFILE WITH ROCKER SWITCH; ALSO CONNECT TO ROOM LIGHT SWITCH. EXISTING EXIT LIGHTING: "SOLO W1GMRLASD-GREEN" FILL H® INDICATES SIDE OF SIGN WITH DIRECTIONAL ARROW EXISTING & NEW EMERGENCY PATHWAY LIGHTS: J "QUANTUM ELM2LF" EXHAUST FAN (MECH ROOM/MED GAS RM): "NUTONE K® QTXEN SERIES EXHAUST FAN QTXEN 150" <150 CFM>; PROVIDE THERMOSTAT SWITCH LIGHTING FIXTURE CONTROLS: SWITCH $2 DIMMABLE SWITCH $os OCCUPANT SENSOR SWITCH CIRCUIT PATHWAY LIGHTING NOTES: 1. USE ONLY UL APPROVED FIXTURES. SUBSTITUTIONS OF NON -RATED FIXTURES ARE NOT APPROVED. ELECTRICIAN TO VERIFY WHETHER 120V OR 277V SOURCE IS AVAILABLE AND ORDER FIXTURES ACCORDINGLY. 2. LIGHT FIXTURES NEED TO BE ORDERED A.S.A.P. AS SOME HAVE LONG LEAD TIMES. LIGHTING FIXTURE SPECS ARE NOT NECESSARILY COMPLETE AND MAY REQUIRE VERIFICATION OF NUMBER, ACCURACY AND ADDITIONAL OPTIONS TO COORDINATE WITH BUILDING POWER REQUIREMENTS. CEILING NOTES & SPECIFICATIONS: 1. EXISTING CEILINGS ARE ALL GWB. 2. ALL NEW SOFFITS --5/8" TYPE 'X' G.W.B. OVER 3-5/8" METAL STUDS, SMOOTH FINISH AND PAINTED FLAT LATEX ENAMEL. UNIT LIGHTING POWER ALLOWANCE (LPA): TOTAL SQUARE FOOTAGE 1,547 S.F. ALLOWABLE WATTS PER SQUARE FOOT N/A TOTAL ALLOWABLE WATTS (LESS THAN 50% OF LIGHTING IS BEING REPLACED) N/A TOTAL EXISTING WATTS (MAXIMUM ALLOWABLE WATTS) SEE WSEC LIGHTING SUMMARY REPORT: 2,002.5 WATTS TYPE EXEMPT FIXTURES (LOC.) LAMPS WATTS EA. COUNT (E) + N WATTS G UNDER CABINET TASK LED - 14 +2 = 16 N/A H EXISTING EXIT SIGNS LED - 2 +0 = 2 N/A J EXISTING EMERGENCY EGRESS LIGHTING LED I - 3 +0 = 3 N/A X2 12 X 4 FLOR TROFFERS (TASK EXCEPTION) 3 TUBES 1 48 6 +0 = 61 N/A TYPE FIXTURES LAMPS WATTS EA. COUNT (E) + N WATTS A 2 X 4 LED TROFFERS LED 48 0 +4 = 4 192 X2 2 X 4 FLORESCENT TROFFERS 3 TUBES 84 10 +0 = 10 840 X4 RECESSED LED CAN LIGHTS LED 11.7 5 +0 = 5 58.5 X5 SURFACE MOUNTED LED LIGHTS LED 36 8 +0 = 8 288 David Company CLIENT / PROJECT: Scott A. Babin, DDS and Associates JOB ADDRESS: Edmonds Office 7631 212th St SW, STE 109C Edmonds, WA 98026 APPROVAL: Stage Completed: Signature: Date: CONSTRUCTION SET REFLECTED CEILING PLAN ISSUE: DATE: REVISIONS: DATE: Drawn By: Checked By: This drawing is the exclusive property of the Architect/Designer and may not be reproduced in part or whole without prior written permission. I D�3 Project No.: 14-72 Date: 5/22/2021 REFLECTED CEILING PLAN SCALE: 1 /4"=1'-0" 0 2' 4' 8' 12' 1 /4"= 1'-O" TOTAL WATTS USED 1,378.5 WATTS MEETS WSEC UNIT LPA 1,378.5 < 2,002.5 WATTS PATCH EXISTING LVT FLOORING PATCH EXISTING CARPET PHASE OF WORK: WALL TYPES: _-rrec�7XA/nQV Qi:7i nr'ATr7n EXISTING WALLS TO REMAIN NEW INTERIOR WALLS -- 5/8" G.W.B. OVER 3-5/8" METAL STUDS @ 24" O.C.; PACKED WITH SOUND BATT INSULATION; SMOOTH FINISH G.W.B. W/ MTL. CORNERS, U.N.O. FINISH PLAN SCALE: 1 /4"=1'-0" ALLOWABLE FLAME SPREAD AND SMOKE DEVELOPMENT CRITERIA: 1. TEXTILE (FABRIC) WALL COVERING SHALL BE CLASS 'A' FLAME SPREAD INDEX IN ACCORDANCE WITH ASTM E84. 2. FLOORS SHALL BE CLASS I OR CLASS II (CLASS II ALLOWED IN SPRINKLERED BUILDINGS PER CODE). DOOR FINISHES: 1. NEW H.M. DOORS, JAMBS AND TRIMS: PAINTED PT-2. CHAIR RAIL FINISH: N/A OUTLET & SWITCH COVER FINISH: 1. REPLACE ALL EXISTING SWITCH PLATES AND ELECTRICAL TRIM: "DECORA" STYLE IN "IVORY" COLOR. GENERAL PAINTING NOTES: 1. ALL PAINTED AREAS TO RECEIVE: - (1) COAT TINTED LATEX WALL PRIMER - (2) COATS PAINT WITH FINAL COAT APPLIED AFTER GENERAL TOUCH UP IS COMPLETED 2. PAINT FINISH, USE 3/4" TO 1" NAP ROLLER: - GENERAL AREAS: "EGGSHELL FINISH" - SOFFITS/CEILING: "FLAT FINISH" - WET AREAS: "SEMI -GLOSS FINISH" 3. CABINET SUBCONTRACTOR TO CAULK ALL CABINETS, COUNTERTOPS, AND BACKSPLASHES THE SAME COLOR AS SURROUNDING WALL SURFACE, TYPICAL UNLESS NOTED OTHERWISE. SOLID SURFACE INSTALLER TO CAULK S.S. MATCH DIRECTION OF EXISTING CARPET PATCH EXISTING CARPET THIS AREA PATCH EXISTING CARPET AND LVT THIS AREA ALIGN LOCATION OF NEW FLOOR TRANSITION WITH OLD 0 2' 4' 8' 12' 1 /4"= 1'-0" FEATHERED CARPET PAD USING CARPET CARPET DOUBLE -STICK GLUE METHOD OR EQ. A GLUED W/ PAD DIRECT LEVERLER SYSTEM TRANSITION -- AT CARPET TO CARPET - SCHLUTER-SCHIENE-AE100 ALUMINUM EDGE OR EQUAL LEVELER SYSTEM OR BUILT-UP B CARPE TILE VINYL SUBFLOORING CARPET TILE LTILE OR LEVEL TRANSITION -- AT CARPET -TO -VINYL (OR TILE) NOTE: USE SELF -LEVELING CONC. TOPPING UNDERLAYMENT, OR JOHNSONITE SUBFLOOR LEVELER SYSTEM (PVC), OR APPROVED EQUAL FOR SMOOTH FEATHERED TRANSITIONS. AT WASHROOMS BUILD UP ENTIRE FLOOR W/ WATER RESIST. PLYWOOD, CONC. LEVELER, OR APPROVED EQUAL (DEPENDING OF SUBFLOOR TYPE) TYP. FLOOR TRANSITIONS FINISH SCHEDULE LEGEND & PRODUCT SPECIFICATION: MATERIAL SPECIFICATION / DESCRIPTION REMARKS / LOCATION CARPET = CPT CPT-1 MFR: MOHAWK GROUP BIGELOW CARPET TILE; GENERAL THROUGHOUT STYLE: CARPET TILE "DATUM" BT284/OB284 COLOR: 7948 "GRANITE" + + + + SIZE: 24% 24" VINYL FLOORING = LVT DIRECTION MFR: MOHAWK GROUP LVT-1 OF GRAIN STYLE: C0007 "SELECT STEP" COLOR: P0065 "DOVETAIL GRAY" OP 5, OP6, HYG 1 AND STAFF RM 111 - - - - - - - - - - - - - - --------------- SIZE:7.25% 48" WALL BASE = WB WB-1 MFR: JOHNSONITE GENERAL AREAS THROUGHOUT, UNLESS NOTED OTHERWISE STYLE: TIGHTLOCK RESILIENT TCBR-179 COLOR: "STEEL" 179 SIZE: 4 1 /2" H PAINT = P P-1 MFR: SHERWIN WILLIAMS WALLS & GWB CEILINGS THROUGHOUT, UNLESS NOTED SPEC: SW 7050 OTHERWISE. SEE GENERAL PAINT NOTES BELOW FOR COLOR: "USEFUL GRAY" APPLICATION AND FINISH. P-2 MFR: SHERWIN WILLIAMS WOOD DOORS, FRAMES AND TRIM SPEC: SW 7047 "PORPOISE" PRO CLASSICS ALKLYD ENAMEL OR EQUAL STAIN= ST ST-1 MFR: - POCKET DOOR, FRAME AND TRIM. GC TO PROVIDE STAIN SPEC: MATCH EXISTING STAIN MATERIAL. PLASTIC LAMINATE = PL PL-1 MFR: WILSONART VERTICAL CABINET SURFACES SPEC: "VAPOR STRANDZ" 4939K-18 PL-2 MFR: PIONITE COUNTERTOPS SPEC: "PASSIN THROUGH" AV250 "SUEDE" David Company CLIENT / PROJECT: Scott A. Babin, DDS and Associates JOB ADDRESS: Edmonds Office 7631 212th St SW, STE 109C Edmonds, WA 98026 APPROVAL: Stage Completed: Signature: Date: CONSTRUCTION SET FINISH PLAN ISSUE: DATE: REVISIONS: DATE: Drawn By: Checked By: This drawing is the exclusive property of the Architect/Designer and may not be reproduced in part or whole without prior written permission. 4. PAINTING SUBCONTRACTOR TO CAULK ALL DOOR TRIM THE SAME COLOR AS SURROUNDING WALL SURFACE, TYPICAL UNLESS NOTED OTHERWISE. 5. ALL WALLS AND GWB CEILINGS AND SOFFITS TO BE PAINTED - T.B.D.. ID-4 Project No.: 14-72 Date: 5/22/2021 PHASE OF WORK: — — PHASE WALL TYPES: EXISTING WALLS TO REMAIN NEW INTERIOR WALLS -- 5/8" G.W.B. OVER 3-5/8" METAL STUDS © 24" O.C.; PACKED WITH SOUND BATT INSULATION; SMOOTH FINISH G.W.B. W/ MTL. CORNERS, U.N.O. PLUMBING & ELECTRICAL PLAN SCALE: 1 /4"=1'-0" ELECTRICAL LEGEND: — — — — — — — — — — — — — — — — — - -POWER FOR T-STAT FAN I I WAITING +72" — 113 I I I +64" nc � I �y RECEPTION O 122 ] 7 U U STAFF GFI +44' 111 GFI +60' RETURN AIR GRILL, (E) T-STAT RELOCATED FROM FLOOR 30"X16" NEW SINK AND FAUCET BY - DENTAL SUPPLIER, INSTALLED BY PLUMBER OD OCO STANDARD DUPLEX RECEPTACLE (+18" A.F.F., U.N.O.) , TELEPHONE JACK (+18" A.F.F., U.N.O.) COMPRESSED AIR D =DEDICATED CIRCUIT; CO = CONTROLLED OUTLET © STANDARD 4-PLEX RECEPTACLE (+18" A.F.F., U.N.O.) DATA JACK-CAT6 (+18" A.F.F., U.N.O.) VACUUM 4-PLEX FLUSH MOUNTED FLOOR RECEPTACLE ELEC. PANEL ® NITROUS GAS 0220v 220V RECEPTACLE (# DENOTES VOLTAGE, +18" A.F.F., U.N.O.) OXYGEN GAS GENERAL ELECTRICAL NOTES: RELOCATE EXISTING UTILITIES TO NEW 12:00 0 2' 4' 8' 12' 1 /42)= 1'-Opp 1. ELECTRICAL PLAN DOES NOT SUPERSEDE FINAL ELECTRICAL PLANS PROVIDED BY DENTAL SUPPLIER. ELECTRICIAN RESPONSIBLE FOR CONTROLLED OUTLETS. 2. PROVIDE CONDUIT FOR ALL EQUIPMENT AS REQUIRED. VERIFY SIZE AND LOCATION WITH COMPUTER CONTRACTOR (DATA WIRING/LOW-VOLTAGE WIRING), CABINET MAKER AND DENTAL EQUIPMENT SUPPLIER. 3. ALL LOW -VOLTAGE WIRING TO BE PROVIDED AND INSTALLED BY OWNER'S CONTRACTOR AND TERMINATED. 4. AT 3/4" THICK FULL HT. BACKSPLASH, EXTEND ELECTRICAL SERVICES 3/4". 5. MOUNTING HEIGHTS FOR ELECTRICAL BOXES (SEE PLAN) ARE TO CENTERLINE OF BOX. IF NO HEIGHT IS SPECIFIED VERIFY W/ DESIGNER. 6. ALL TREATMENT ROOMS REQUIRE SEPARATE GROUND WIRE PER WSEC, SEE DENTAL EQUIPMENT SUPPLIERS PLANS FOR ALL EQUIPMENT NEEDS. 7. SEE FINISH SCHEDULE FOR COLOR OF OUTLET COVERS AND TOGGLE SWITCHES. WHEN COLOR DENOTATION IS REQUIRED BY CODE, USE APPROPRIATELY COLORED DOT. LIGHTING SWITCH TO BE SINGLE -POLE ROCKER STYLE. 8. VERIFY NUMBER OF CPU'S TO BE GROUPED PER CIRCUIT WITH COMPUTER INSTALLER (4 MAX.) USE GRAY DOT TO DENOTE COMPUTER OUTLETS. 9. MICROWAVE IN STAFF LOUNGE: OWNER FURNISHED, OWNER INSTALLED (O.F.0.1.) 10. PROVIDE AND INSTALL 2 INCH SMURF TUBE FROM 12:00 TO FOOT OF DENTAL CHAIR. APPLIANCE SCHEDULE: QTY. ITEM LOCATION SPECIFICATION 1 REFREGERATOR RM111-STAFF OWNER FURNISHED, OWNER INSTALLED 1 DISHWASHER RM111-STAFF OWNER FURNISHED, PLUMBER INSTALLED 1 MICROWAVE RM111-STAFF OWNER FURNISHED, OWNER INSTALLED GENERAL APPLIANCE NOTES: 1. OWNER TO FURNISH AND CONTRACTOR TO INSTALL APPLIANCES AS NOTED. 2" SMURF TUBE FOR LOW VOLTAGE, -TYP ALL NEW OPS PLUMBING FIXTURE SCHEDULE: QTY. ITEM LOCATION SPECIFICATION FIXTURES/FITTINGS 1 WASHER BOX RM102—(E) LAB STANDARD ROUGH —IN BY PLUMBER REUSE EXISTING SINK AND FAUCET ROUGH -IN AND TRIM BY PLUMBER 1 SINK RM111-STAFF 2 SINK RM109-SURGICAL OP 6 12" SINK BOWLS AND FAUCETS SUPPLIED BY DENTAL SUPPLIER. ROUGH -IN AND TRIM BY PLUMBER & RM107-HYG 1 REUSE EXISTING FOR SURGICAL OP. GENERAL PLUMBING NOTES: 1. ALL ENGINEERED PLUMBING PLANS TO BE SUBMITTED UNDER SEPARATE PERMIT. 2. PROVIDE HOT & COLD WATER TO ALL SINK AND WASHER/DRYER LOCATIONS. PLUMBER TO PROVIDE ROUGH -IN FOR ALL NEW SINKS. 3. SINKS IN OPERATORIES: SIDE CABINETS AND SPLIT UNIT SINKS & FAUCETS TO BE PROVIDED BY DENTAL EQUIPMENT SUPPLIER AND INSTALLED BY PLUMBER. 4. EACH OPERATORY TO BE SUPPLIED W/ POWER, COMPRESSED AIR, SUCTION AND TO BE COORDINATED ON -SITE WITH DENTAL EQUIPMENT SUPPLIERS. 5. VERIFY WITH DENTAL SUPPLIER - "ASSISTINA" IN STERILIZATION ROOM, FOR HANDPIECE LUBRICATION, WILL REQUIRE POWER AND AIR LINE. 6. BOTTLED WATER TO BE USED AT ALL 12:00 LOCATIONS AT OPERATORIES. MECHANICAL NOTES: 1. 150 CFM EXHAUST FAN WITH T-STAT AT LAN CLOSET. 2. RELOCATE RETURN AIR GRILLE AT FLOOR IN WAITING TO WALL PER PLAN. David Company CLIENT / PROJECT: Scott A. Babin, DDS and Associates JOB ADDRESS: Edmonds Office 7631 212th St SW, STE 109C Edmonds, WA 98026 APPROVAL: Stage Completed: Signature: Date: CONSTRUCTION SET PLUMB. & ELEC. PLAN ISSUE: DATE: REVISIONS: DATE: Drawn By: Checked By: This drawing is the exclusive property of the Architect/Designer and may not be reproduced in part or whole without prior written permission. ID-5 Project No.: 14-72 Date: 5/22/2021 MISCELLANEOUS ACCESSORIES & CABINET HARDWARE - SCHEDULE & SPECIFICATIONS: OTY. ITEM LOCATION SPECIFICATION VERIFY CABINET PULL HANDLES THROUGHOUT, U.N.O. "PENTCO" #1225—SN, 5-1/2" SATIN NICKEL BOW PULL (SEE ELEVATIONS FOR LOCATION). USE PULLS FOR CAB. DOORS AND DRAWERS. MOUNT VERTICAL FOR CAB. DOOR PULLS AND HORIZONTAL FOR DRAWER PULLS. VERIFY STANDARD DRAWER SLIDES THROUGHOUT, U.N.O. "ACCURIDE" #3732 FULL EXTENSION SLIDES, 100 LB. RATING W/ ZINC FINISH, 22" DEPTH. VERIFY HEAVY—DUTY DRAWER SLIDES FILE DRAWERS THROUGHOUT, "ACCURIDE" #4034 FULL EXTENSION+1" SLIDES, 150 LB. RATING W/ ZINC FINISH, 22" DEPTH. FILE & PLASTER DRAWERS, STATIM DRAWERS INCLUDE HARDWARE FOR PENDAFLEX HANGING FILES. VERIFY HINGES THROUGHOUT, U.N.O. CONCEALED "BLUM" #71 T5580, 120°SELF—CLOSING CLIP —ON. VERIFY SHELF SUPPORT PINS THROUGHOUT, U.N.O. "HAFELE" #282.04.712 ANTI SLIDE SPOON STYLE SUPPORT W/ NICKEL FINISH. VERIFY CABINET LOCKS (DRAWERS) AS NOTED ON ELEVATIONS "HAFELE" CAM LOCK #235.08.018.77 W/ NICKEL FINISH. VERIFY CABINET LOCKS (SINGLE DOORS) AS NOTED ON ELEVATIONS "HAFELE" CAM LOCK #235.08.152 VERIFY CABINET LOCKS (DOUBLE DOORS) AS NOTED ON ELEVATIONS "HAFELE" CAM LOCK #235.08.017.77 N/A COMPUTER RACKS (UNDERCOUNTER) AS NOTED ON ELEVATIONS FURNISHED AND INSTALLED BY OWNER N/A WIRE RACKS STERIL. "HAFELE" 1 /4" STAINLESS STEEL WIRE AND 8" — 10" LONG AT 2" ON CENTER. (VERIFY W/ DR.) N/A VERTICAL DIVIDERS CHECKOUT @ PIGEON —HOLES CLEAR 1/4" PLEXIGLASS, U.N.O. N/A KEYBOARD TRAYS PER PLAN OR AS NOTED "WATERLOO" TYPE #6170D WITH BLACK TRAY #6201D" OR EQUAL, FULLY ADJUSTABLE. N/A GLASS SHELVING SUPPORTS SMILE STORE AREA "CR LAURENCE CO. CATALOG # DL661 CH", CHROME FINISH; 6 PER SHELF X 3 SHELVES. N/A CONCEALED PAPER TOWEL DISPENSER STERIL. "GREENO 1 T—EC" 9" HIGH PAPER TOWEL DISPENSER, TO BE PLACED INSIDE CABINET W/ DISPENSING CUT—OUT AT CABINET BOTTOM. N/A ULTRASONIC TUB STERIL. "GREENO" ULTRASONIC TUB, SIZE TBD, VERIFY WITH DESIGNER N/A SHARPS COLLECTOR STERIL. "GREENO SCH—M" THRU COUNTERTOP SHARPS COLLECTION, MEDIUM MOUTH (SEE ELEVATIONS FOR LOCATION). N/A WASTE CHUTE/COLLAR STERIL. "GREENO WC-6" BIO—WASTE CHUTE W/ BAG HOLDING COLLAR & LID (SEE ELEVATIONS FOR LOCATION). VERIFY TRASH GROMMET THROUGHOUT, U.N.O. "DOUG MOCKETT TM113" TRASH MANAGEMENT GROMMET, 6" DIA., 2" DEEP IN POLISHED STAINLESS STEEL (SEE PLANS AND ELEVATIONS FOR LOCATION). N/A COAT HOOKS VERIFY "T.B.D." MOUNT ON CENTER OF DOOR © 66" A.F.F. N/A COAT ROD & SHELF — SATIN CHROME COAT ROD & MELAMINE SHELF (SEE ELEVATIONS FOR LOCATION). VERIFY COUNTERTOP IN —WALL BRACKET SUPPORTS THROUGHOUT, U.N.O. 1% 1" TUBE STEEL MOUNTED TO STUDS PRIOR TO G.W.B., SEE DETAIL THIS SHEET. GENERAL CABINETRY/CASEWORK NOTES: 1. ALL UPPERS TO BE 15" DEEP (SEE DETAIL) WITH ADJUSTABLE SHELVING, AND TO BE A MAXIMUM OF 24" ABOVE COUNTERTOP HEIGHT, UNLESS OTHERWISE SPECIFIED. 2. 4" TOE KICKS TO BE UNFINISHED --BASE BY OTHERS --VERIFY WITH FINISH SCHEDULE ABOVE. 3. ALL INTERIORS OF CABINETS TO BE WHITE MELAMINE/POLYESTER OR APPROVED EQUAL. 4. ALL OPEN CABINETS TO HAVE HIGH PRESSURE LAMINATE TO MATCH EXTERIORS. 5. ALL BACKSPLASHES MUST BE MECHANICALLY FASTENED TO THE TOP, SCRIBED TO WALLS, AND MUST BE FLUSH TO EDGE OF TOP, UNLESS OTHERWISE SPECIFIED. 6. NO 3/4" SHELF SHALL SPAN LONGER THAN 32" WITHOUT SUPPORT. 7. ALL CABINETS AND DOORS SHALL BE CONSTRUCTED FROM 3/4" THICK MATERIAL, UNLESS APPROVED PRIOR TO EACH JOB. 8. FACES OF PIGEONHOLES TO MATCH WORK SURFACE LAMINATE, U.N.O. 8. COLOR OF EDGE BANDING ON ALL DOORS TO MATCH FACE MATERIAL. 9. SHOP DRAWINGS MUST BE PROVIDED FOR FINAL REVIEW TO DESIGNER AND CLIENT, SEE SHOP DRAWING NOTE. 10. ALL UPPER CABINET DOORS TO HANG 3" BELOW CABINET TO CREATE A VALANCE FOR UNDERCABINET TASK LIGHT. TASK LIGHTING TO BE MOUNTED AT FRONT OF CABINET WITH LENS POINTING TOWARD WALL FOR AMBIENT LIGHTING. 11. ALL COUNTERTOPS TO BE 24" DEEP UNLESS OTHERWISE SPECIFIED. --ATTENTION-- SHOP DRAWING NOTE: THE CONTRACTOR IS TO BRING TO ATTENTION AND NOTE ANY DISCREPANCIES FOUND IN THE DESIGNER'S DRAWINGS OR WITH SUBCONTRACTOR'S SHOP DRAWINGS FOR THE DESIGNER'S REVIEW AND APPROVAL PRIOR TO FABRICATION. THE DESIGNER'S DRAWINGS AND AMENDMENTS HAVE PRECEDENCE OVER THE SHOP DRAWINGS WHEN DISCREPANCIES ARISE BETWEEN THE TWO. APPROVAL OF THE SHOP DRAWINGS DOES NOT IMPLY A CHANGE FROM THESE DESIGN DRAWINGS OR AMENDMENTS UNLESS NOTED BY THE DESIGNER OR APPROVED AGENT ON THE SHOP DRAWINGS AND/OR ATTACHMENTS TO SAME. LU Q � o J w J z RATING FIRE SOUND TEST VALUE N/A N /R FRAME SIZE / GAUGE / SPACING METAL 3-5/8"/ 20 MIN./ 24" O.C. FACING MATERIAL / THICKNESS 1 LAYER GWB 5/8" SOUND BA —TYP. I APPLIED FINISH (SEE FINISH SCHEDULE) PLAN /�STRUCT. I CEILING LINE FLOOR SECTION EXISTING GLAZING 5/8" G.W.B, EA. SIDE OVER METAL STUDS BREAK SHAPE TO BE 5" ON THE INSIDE WITH 1" LEGS DOUBLE BACK GREY TAPE 1. WALL PARTITION BREAK SHAPE DETAIL SOLID BLOCKING: 1. LOCATE BLOCKING AT EACH END OF WALL AND ADJACENT TO OPENINGS. 2. WHERE BLOCKING MATERIAL THICKNESS ALLOWS, NOTCH AND BEND FLANGES 90° OR ANCHOR TO VERTICALS W/ CLIP ANGLES. #10 SCREW EA. SIDE OF STUD 2" FLAT STRAP EA. SIDE LAP SPLICE STRAPS MINIMUM 4". (3)—#10 SCREWS MIN. STRAPPING EA. SIDE OF BLKG. NOTES: 1. CONTINOUS HORIZONTAL SOLID BLOCKING, BRIDGING, OR STRAPPING IS REQ'D AT ALL STEEL STUD WALLS, WITH SPACING NOT TO EXCEED 4'-0". 2. WHERE BLOCKING MATERIAL THICKNESS ALLOWS, NOT BEND TRACK 90° FOR CONNECTION. CLIP ANGLE ATTACHMENT TO STUD & BLOCKING i SOLID BLOCKING CLIP ANGLE ATTACHMENT WITH (4)—#10 SCREWS AS SHOWN. COLD —ROLLED CHANNEL. / ORIZONTAL BRIDGING BRIDGING TYP. WALL BLOCK / BRIDGING (REQ'D. FOR WALLS OVER 9'-0" A.F.F. ONLY) #10 SCREWS @ 8" O.C. TO CONNECT TO BEAM OR JOIST ABOVE INSTALL STUDS WITH V (1)—#10 SAME DIMENSION FOR SCREW ON BRIDGING ALIGNMENT EACH SIDE OF STUD (1)—#10 SCREW ON EACH SIDE OF STUD TYP. STUD TO TRACK CONNECTION TYP. TRACK TO CONC. CONNECTION (2) #8 SCREWS, —TYP. -BOT. OF EXISTING CONCRETE STRUCTURE, —TYP. 0 PARTITION BRACES, 1 (2) #8 SELF —DRILLING _I 350S125-18 © 6'-0" SCREWS THRU TOP OF O.C., ALTERNATE WALL TRACK DIRECTION -- 8'— 6" A.F.F. SUSPENDED CEILING — - 5/8" G.W.B, EA. SIDE----------- 11,,11 —TEGULAR TILE SPACER TYP. WALL BRACING / FRAMING X 0 w vi zM:2 :2 0 O_ w 0 X 3: -_ O _I m\J NZry 0 v `-- 1"X 1" T.S. W/ (3) SCREW TYP. IN -WALL METAL L-BRACKET TO STUD i� �y -CAN EXTEND FOR MORE SUPPORT AS NEEDED TO EQUAL 24" MIN. FOR LOWER COUNTERS OR BENCHES kk WELD "V" W/ FULL PENETRATION iFs ® OF COO, U tir NOTE: SPACING NOT TO EXCEED 48" O.C. MIN. FOR UNSUPPORTED SPANS OF COUNTERTOP OR BENCH. ALL WELDS ARE TO BE FULL LENGTH. HOLES TO BOTTOM OF COUNTERTOP SECURE T.S. TO STUDS W/ \�-- 3/4"� BOLTS PRIOR TO GWB David Company CLIENT / PROJECT: Scott A. Babin, DDS and Associates JOB ADDRESS: Edmonds Office 7631 212th St SW, STE 109C Edmonds, WA 98026 APPROVAL: Stage Completed: Signature: Date: CONSTRUCTION SET DETAILS ISSUE: DATE: REVISIONS: DATE: Drawn By: Checked By: This drawing is the exclusive property of the Architect/Designer and may not be reproduced in part or whole without prior written permission. D-6 Project No.: 14-72 Date: 5/22/2021 C I ca VENTILATION FAN WITH T—STAT ABOVE CEILING F —1 RELOCATED UPPER CABINETS P.LAM SURFACE (PL-1) MODIFY RELOCATED — — COUNTERTOP TO FIT LAN CLOSET p p LOCKS PER CABINET HARDWARE SCHEDULE —TYP. 2 DOORS 2'-0" VENTILATION THROUGH DOOR W/ 4" TOEKICK WITH WALL BASE ADJ. SHELVES W/ NOTCHED OUT BACK (2% 1/4" SLAT HOLES 18") FOR VENTILATION, —TYP. FLOOR TO CEILING 1. RM 112- RECEPTION DESK - LAN CLOSET P.LAM VERTICAL (PL-1) VERIFY _ 0 -- -- — �— I 0 0 4" P.LAM COUNTERTOP BACKSPLASH (PL-2) 00 00 0 0 0 — REF'R. (O.F.C.I.) R 0 N 7Wj' _ VERIFY 3'-6 1 /2" 2. RM 112 - STAFF — MICROWAVE (O.F.C.I.) --3" RADIUS CORNERS, SHELF CANTILEVERS OUT TO HOLD MICROWAVE } w w P.LAM VERTICAL VERIFY (PL-1) 91-0" 0 I 00 :I►TA"PAMr_199 P.LAM COUNTERTOP (PL-2) J-WALL BRACKETS BY CABINET SUBCONTRACTOR, INSTALLED BY GC 0 00I P.LAM VERTICAL (PL-1) 2'-0" ro I o I ih c P.LAM COUNTERTOP iv (PL-2) /-PENCIL DRAWER io I N El0V8Air1%3 w•]99Is] zI 0 I N V, David Company CLIENT / PROJECT: Scott A. Babin, DDS and Associates JOB ADDRESS: Edmonds Office 7631 212th St SW, STE 109C Edmonds, WA 98026 APPROVAL: Stage Completed: Signature: Date: CONSTRUCTION SET INTERIOR ELEVATIONS ISSUE: DATE: REVISIONS: DATE: Drawn By: Checked By: This drawing is the exclusive property of the Architect/Designer and may not be reproduced in part or whole without prior written permission. ID�7 Project No.: 14-72 Date: 5/22/2021