1010035_Manufacturer_Specifications_and_Installation_Instructions_08-24-2021800SA/
Legacy 80, 80% AFUE, Single -Stage, Multi -Speed ECM,
Non -Condensing Gas Furnaces LL CO.
Product Data
PERFORMANCE
® ®
Single Stage gas valve
Fixed -Speeds, Constant Torque (FCT) ECM blower motor
Il
QuieTechT111 noise reduction system
4
Microprocessor based "smart" control center
Adjustable heating air temperature rise
®®®®
Enhanced diagnostics with LED and reflective sight glass,
non-volatile fault code memory, and self test feature
Perfect LightT11 Igniter
Patented blocked vent safeguard designed to ensure proper furnace
venting
• Inner door for tighter sealing
INSTALLATION FLEXIBILITY
• 4-way Multipoise furnace, 13 vent applications
HYBRID HEAT® Dual Fuel System compatible
All models are chimney friendly when used with accessory vent kit
I
• Select sizes approved for twinning, refer to accessory kit listing
A190165
��800SA GAS FURNACE1 SA LegacyT"r Line 4-way Multipoise Gas Furnaces
feature Bryant's QuieTechTm noise reduction system for incredibly quiet
induced draft operation. Applications are easy with 4-way multipoise
design, through -the -furnace downflow venting, 13 different venting
options, and designed for easy service access. An inner blower door is
provided for tighter sealing in sensitive applications. The 800SA/801SA
furnaces are approved for use with natural or propane gas, and the
801 SA- Low NOx units are designed for California installations and can
be installed in air quality management districts with a 40 ng/J NOx
emissions limit.
e
Z,
D
�� � lll��fOltY
'� pl1T��Iriy11D
� U �
rJ 1'll
1
LEGACY'
LINE
Use of the AHM Certified TM Mark indicates a
n=ufaeturer'e pa Uclpatlon in the progrsm. For
verification of certification for indlAdual products,
go to www.ahridirectoryotg.
A210031
APPLICATIONS
• Compact design - only 33-1/3 in. (847 nun) tall
• Propane convertible with gas conversion accessory
• Convenient Air Purifier and Humidifier connections
CERTIFICATION
• Cabinet air leakage less than 2.0% at 1.0 in. W.C. and cabinet air
leakage less than 1.4% at 0.5 in. W.C. when tested in accordance with
ASHRAE standard 193
• Residential installations eligible for consumer financing through the
Retail Credit Program
800SA1801SA: Product Data
SPECIFICATIONS
/
Unit Size
36045E14
36045E17
36070E14
36070E17
48070E17
4807OE21
42090E17
RATINGS AND PERFORMANCE
All Standard
Input Btuh} All Low NOx Upflow
44,000
44,000
66,000
66,000
66,000
66,000
88,000
Nonweatherized ICS All Low Nox
Downflow/Horizontal
42,000
42,000
63,000
63,000
63,000
63,000
84,000
Output Capacity All Standard
(Btuh)t All Low NOx Upflow
36,000
35,000
54,000
54,000
54,000
53,000
71,000
Nonweatherized ICS All Low Nox
Downflow/Horizontal
34,000
34,000
51,000
51,000
51,000
51,000
68,000
AFUEt
80%
Certified Temperature Rise Range - °F (*C)
30-60
(17-33)
30-60
(17-33)
30-60
(17-33)
35-65
(19-36)
25-55
(14-30)
25-55
(14-30)
40-70
(22-39)
Certified External Heat/Cool
Static Pressure
0.10/0.50
0.10/0.50
0.12/0.50
0.12/0.50
0.12/0.50
0.12/0.50
0.15/0.50
Heating
710
760
1090
985
1175
1305
1203
Airflow CFM$ Cooling
1080
1215
1070
1005
1515
1545
1210
ELECTRICAL
Unit Volts -Hertz -Phase
115-60-1
Operating Voltage Min -Max
Range
104-127
Maximum UnitAmps
5.6
7.6
5.6
5.6
10.8
10.0
8.3
UnitAmpacity
7.8
10.3
7.8
7.8
14.3
13.3
11.0
Maximum Wire Length
(Measure 1 Way in Ft (M)
47 (14.3)
36 (11)
47 (14.3)
47 (14.3)
25(7.6)
27(8.2)
33 (10.1)
Minimum Wire Size
14
Maximum Fuse or Ckt Bkr Size (Amps)'*
15
Transformer (24v)
40va
External Control Heating
12va
Power Available Cooling
35va
Air Conditioning Blower Relay
Standard
Controls
Heating Blower Control
Solid State Time Operation
Burners (Monoport)
2
2
3
3
3
3
4
Gas Connection Size
1/2in. NPT
GAS CONTROLS
Mfr
WhiteRodgers
Gas Valve Min. inlet pressure
4.5 (Natural Gas)
(In. W.C.)
(Redundant)
Max. inlet pressure
13.6 (Natural Gas)
(In. W.C.)
Ignition Device
Hot Surface
Factory installed orifice
Size 43
BLOWER DATA
Direct Drive Motor HP
1/3
1/2
1/3
1/3
314
3/4
1/2
Motor Full Load Amps
4.4
6.4
4.4
4.4
9.60
8.8
6.8
RPM (Nominal)Speeds
1050-5
1050-5
1050-5
1050-5
1050-5
1050-5
1050-5
Blower Wheel Diameter x Width - In. (mm)
10 x 6
10 x 8
10 x 6
11 x 8
11 x 8
10 x 10
11 x 8
(254 x 152)
(254 x 203)
(254 x 152)
(279 x 203)
(279 x 203)
(254 x 254)
(279 x 203)
*. Gas input ratings are certified for elevations to 2000 ft. (610 M). In USA, For elevations above 2000 ft (610 M), reduce ratings 4 percent for each 1000 ft (305 M) above sea
level. Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1 Table FA or fiimace installation instructions.
t. Capacity in accordance with U.S. Government DOE test procedures.
$. Airflow shown is for bottom only retum-air supply for the as -shipped speed tap. For air delivery above 1800 CFM, see Air Delivery table for other options. A filter is required
for each return -air supply. An airflow reduction of up to 7 percent may occur when using the factory -specified 4-5/16-in. (110 iron) wide, high efficiency media filter..
**. Time -delay type is recommended.
ICS = isolated Combustion System
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
2
800SA1801SA: Product Data
SPECIFICATIONS (continued)
Unit Size 4809OE21 6009OE21 6009OE24 6011OE21 60110E24 60135E24 60155E24
RATINGS AND PERFORMANCE
All Standard
Input Btuh* All Low NOx Upflow
88,000
88,000
88,000
110,000
110,000
132,000
154,000
Nonweatherized ICS All Low NOx
Downflow/Horizontal
84,000
84,000
84,000
105,000
105,000
126,000
147,000
Output Capacity All Standard
(Btuh)t All Low NOx Upflow
72,000
71,000
72,000
90,000
90,000
107,000
125,000
Nonweatherized ICS All Low NOx
Downflow/Horizontal
68,000
68,000
69,000
85,000
86,000
102,000
119,000
AFUEt
80%
Certified Temperature Rise Range °F (°C)
35-65
(19-36)
25-55
(14-30)
30-60
(17-33)
30-60
(17-33)
30-60
(17-33)
40-70
(22-39)
45-75
(25-41)
Certified External Heat/Cool
Static Pressure
0.15/0.50
0,15/0.50
0.15/0.50
0.20/0.50
0.20/0.80
0.20/0.50
0.20/0.50
Heating
1418
1650
1565
1890
1930
1760
1950
Airflow CFM$ Cooling
1445
1980
1960
2040
2005
1810
1965
Electrical
Unit Volts -Hertz -Phase
115-60-1
Operating Voltage Min -Max
Range
104-127
Maximum UnitAmps
8.3
13
10.3
13.4
10.7
10.7
10.7
Unit Ampacity
11
16.90
13.50
17.40
14
14
14
Maximum Wire Length (Measure 1 Way in Ft
(M))
33 (10.1)
34 (10.4)
27(8.2)
33 (10.1)
26(7.9)
26(7.9)
26(7.9)
Minimum Wire Size
14
12
14
12
14
14
14
Maximum Fuse or Ckt Bkr Size (Amps)**
15
20
115
20
15
15
15
Transformer (24v)
40va
External Control Heating
12va
Power Available Cooling
35va
Air Conditioning Blower Relay
Standard
CONTROLS
Heating Blower Control
SolidState Time Operation
Burners (Monoport)
4 4 4 5 5 6 7
Gas Connection Size
1/2in. NPT
GAS CONTROLS
Mfr.
WhiteRodgers
Gas Valve Min. inlet pressure
(In. W.C.)
4.5 (Natural Gas)
(Redundant)
Max. inlet pressure
(In. W.C.)
13.6 (Natural Gas)
Ignition Device
Hot Surface
Factory installed orifice
Size 43
BLOWER DATA
Direct Drive Motor HP
1/2
1
3/4
1
3/4
3/4
3/4
Motor Full Load Amps
6.80
11.50
8.80
11.50
8.80
8.80
8.80
RPM (Nominal)Speeds
1050-5
1050-5
1050-5
1050-5
1050-5
1050-5
1050-5
Blower Wheel Diameter x Width - In. (mm)
10 x 10
(254 x 254)
11 x 11
(279 x 279)
11 x 11
(279 x 279)
11 x 11
(279 x 279)
11 x 11
(279 x 279)
11 x 11
(279 x 279)
11 x 11
(279 x 279)
'. Gas input ratings are certified for elevations to 2000 ft. (610 M). In USA, for elevations above 2000 ft. (610 M), reduce ratings 4 percent for each 1000 ft. (305 M) above sea
level. Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1 Table FA or furnace installation instructions.
t. Capacity in accordance with U.S. Government DOE test procedures.
$. Airflow shown is for bottom only retum-air supply for the as -shipped speed tap. For air delivery above 1800 CFM, see Air Delivery table for other options. A filter is required
for each return -air supply. An airflow reduction of up to 7 percent may occur when using the factory -specified 4-5/16-in. (110 min) wide, high efficiency media filter..
•t. Time -delay type is recoimnended,
ICS = Isolated Combustion System
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
800SA1801SA: Product Data
MODEL NUMBER NOMENCLATURE
1
2
3
Heat
Exchanger
Tier/NOx
AFUE/NOx
9
8
7
0 — 80%
0 = Base
1 = 80% Low Nox
1 = Legacy Line
2 = Preferred
2 = 92%
3 = Ultra Low Nox
5 = 95%
B = Evolution
6 = 96%
7=97%
8 = 98%
4 5 6,7
Major Cooling
Heating Stages Series Capacity (CFM)
M B 42
1 ( 1
M = Modulating
S = Single Stage
T = Two -Stage
FURNACE COMPONENTS
INDUCER MOTOR
ASSEMBLY
PRESSURE
SWITCH
FLUE COLLECTOR
BOX
GAS VALVE
MANUALRESET
LIMIT SWITCHES
HOT SURFACE
IGNITOR
BLOWER
DOOR SAFETY
SWITCH
FURNACE
CONTROL
BOARD
A
B
C
D
= 800 CFM
= 1000 CFM
= 1200 CFM
= 1400 CFM
= 1600 CFM
= 2000 CFM
= 2200 CFM
8-10
11
12-13
14
15 16
Voltage
Minor
Heating Input
Motor Type
Width
(1-phase)
Un-used Series
060
C
17
A
A
C = Comm. Variable -
Speed
Constant Airflow
Ec
(VGA) ECM
14 = 142.
= 110V/60Hz
E= Fixed -Speeds
Constant Torque
17 = 17.5•
21=21.0°
24=24.5°
-
26 = 26,000 BTUh
(FCT)ECM
V = Varlable-Speed
40=40,000 BTUh
Constant Torque
60 = 60,000 BTUh
(VCT) ECM
55 = 155,000 BTUh
VENT
ELBOW
MAW LIMIT SWITCH
(BEHIND GAS VALVE)
BLOCKEDVENT
SWITCH
FLAME
SENSOR
GAS MANIFOLD
GASBURNER
BLOWER AND
MOTOR
A200522
A190086
NOTE: The furnaces are factory shipped for use with natural gas. These furnaces can be field -converted for propane gas with a factory -authorized and
listed accessory conversion kit.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
4
800SA/801SA: Product Data
ACCESSORIES
DESCRIPTION
PART NO.
36045E14
36045E17
36070E14 I
36070E17
14807OE17
4807OE21
42090E17
External Bottom Return Filter Rack;
FHG1425-2
X
-
X
-
-
FHG1625-2
-
X
-
X
X
-
X
FHG2025-2
-
-
-
-
-
X
-
Unframed Filter 3/4-in. (19 mm)*
325531-402
X
X
X
X
X
-
X
325531-403
-
-
-
-
-
X
Flue Extension
KGAFE0112UPH
X
X
X
X
X
X
X
Combustible Floor Base
KGASB0201ALL
X
X
X
X
X
X
X
Downflow Vent Guard
KGBVG0101 DFG
X
X
X
X
X
X
X
Vent Extension Kit
KGAVE0101 DNH
X
X
X
X
X
X
X
Coil Adapter Kit
KGADA0101ALL
X
X
X
X
X
X
X
KGADA0201ALL
X
X
X
X
X
X
X
KGADA0301ALL
X
X
X
X
X
X
X
Chimney Adapter Kit
KGACA02014FC
X
X
X
X
X
X
X
Natural -to -Propane Conversion Kitt
AGAGC8NPS01A
X
X
X
X
X
X
X
Propane -to -Natural Conversion Kitt
AGAGC8PNS01A
X
X
X
X
X
X
X
Twinning Kit FCT-ECM Motor
AGATWNDTE01A
-
-
-
-
-
X
Blower Speed Tap Jumper Kit
(10 pack)
AGABLRJMP10A
X
X
X
X
X
X
X
*. Purchased through Replacement Components
j. Factory -authorized and field installed. Fuel conversion kits are CSA (formerly AGA/CGA) recognized.
X = Accessory
DESCRIPTION
PART NO.
48090E21
6009OE21
6009OE24
60110E21
60110E24
60135E24
60155E24
External Bottom Return
Filter Rack*
FHG2025-2
X
X
-
X
-
-
-
FHG2424-2
-
-
X
X
X
X
Unframed Filter 3/4-in.
(19 mm)*
325531-403
X
X
-
X
-
-
-
325531-404
-
-
X
-
X
X
X
Flue Extension
KGAFE0112UPH
X
X
X
X
X
X
X
Combustible Floor Base
KGASB0201ALL
X
X
X
X
X
X
X
Downflow Vent Guard
KGBVG0101DFG
X
X
X
X
X
X
X
Vent Extension Kit
KGAVE0101DNH
X
X
X
X
X
X
X
Coil Adapter Kit
KGADA0101ALL
X
X
X
X
X
X
X
KGADA0201ALL
X
X
X
X
X
X
X
KGADA0301ALL
X
X
X
X
X
X
X
Chimney Adapter Kit
KGACA02014FC
X
X
X
X
X
-
-
KGACA02015FC
-
-
-
-
-
X
X
Natural -to -Propane
Conversion Kitt
AGAGC8NPS01A
X
X
X
X
X
X
X
Propane -to -Natural
Conversion Kitt
AGAGC8PNS01A
X
X
X
X
X
X
X
Twinning Kit FCT-ECM
Motor
AGATWNDTE01A
X
X
X
X
X
X
X
Blower Speed Tap Jumper
Kit
(10 pack)
AGABLRJMP10A
X
X
X
X
X
X
X
•. Purchased through Replacement Components
t. Factory -authorized and field installed. Fuel conversion kits are CSA (formerly AGA/CGA) recognized.
X = Accessory
ORFICIES
Gas Orifice Kit - #42 (Nat Gas)
LH32DB207
See Installation Instructions for model, altitude,
and heat value usages.
Gas Orifice Kit -#43 (Nat Gas)
LH32DB202
Gas Orifice Kit - #44 (Nat Gas)
LH32DB200
Gas Orifice Kit - #45 (Nat Gas)
LH32DB205
Gas Orifice Kit - #46 (Nat Gas)
LH32DB208
Gas Orifice Kit - #47 (Nat Gas)
LH32DBO78
Gas Orifice Kit - #48 (Nat Gas)
LH32DBO76
Gas Orifice Kit - #54 (LP)
LH32DB203
Gas Orifice Kit - #55 (LP)
LH32DB201
Gas Orifice Kit - #56 (LP)
LH32DB206
Gas Orifice Kit-1.25mm (LP)
LH32DB209
Gas Orifice Kit-1.30mm (LP)
LH32DB210
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
800SA1801SA: Product Data
AIR DELIVERY - CFM (with filter) (Continued)
Furnace
Wire
Lead
Color
Function
Test Airflow Delivery @ Various External Static Pressures
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
Gray
Cooling. Do not use for heating.
2065
2006
1940
1875
1810
1740
1670
1600
1530
1470
Blue
Heating or alt Cooling
1825
1760
1695
1630
1560
1490
1420
1350
1275
1205
60135E24
Yellow
Alt Cooling or alt Heating
1760
1690
1625
1555
1485
1415
1345
1275
1200
1130
Orange
Alt Cooling. Do not use for heating.
1620
1550
1480
1405
1335
1260
1195
1 1130
1065
995
Red
Alt Cooling. Do not use for heating.
1325
1260
1185
1100
1025
955
885
805
735
670
Gray
Cooling. Do not use for heating.
2205
2150
2090
2030
1965
1905
1840
1780
1710
1645
Blue
Heating or alt Cooling
2055
1995
1935
1875
1810
1750
1690
1615
1540
1460
60155E24
Yellow
Alt Cooling or all Heating
1860
1795
1730
1670
1605
1540
1470
1395
1320
1250
Orange
Alt Cooling. Do not use for heating.
1495
1430
1355
1285
1210
1130
1065
995
930
850
Red
Alt Cooling. Do not use for heating.
1295
1085
1000
910
835
765
670
600
530
465
FOOTNOTES
I.A filter is required for each return -air inlet. Airflow performance included 3/4-in. (19 mm) washable filter media (see accessory list). To determine airflow performance without this filter,
assume an additional 0.1 In. W.C. available external static pressure.
2.Adjust the blower speed tabs as necessary for the proper air temperature rise for each installation.
3: - Indicates unstable operating conditions.
4.If the same motor speed tap is needed for heating and cooling, a Juniper Wire accessory kit is available (see Product Data sheet for the current Juniper Wire accessory part number), see
Function column for applicable limitations.
_ I O
SEE NOTES: 1,2,4,5,7,8,9
HORIZONTAL RIGHT A02068
SEE NOTES: 1,2,4,7,8,9
A02069
HORIZONTAL RIGHT
SEE NOTES: 1,2,4,5,7,8,9
HORIZONTAL LEFT A02065
SEE NOTES: 1,2,4,5,7,8,9
A02066
SEE NOTES: 1,2,4,5,7,B,9
A02070
HORIZONTAL RIGHT
HORIZONTAL LEFT
SEE NOTES: 1,2,4,5,7,8,9
A02067
SEE NOTES: 1,2,4,7,8,9
A02064
HORIZONTAL LEFT
HORIZONTAL LEFT
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
8
800SA/801SA: Product Data
SEE NOTES: 1,2,4,7,8,9
A02058
UPFLOW
SEE NOTES: 1,2,3,4,7,8,9
A02059
UPFLOW
SEE NOTES: 1,2,4,5,7,8,9
SEE NOTES:1,2,3,4,5,7,8,9
DOWNFLOW
SEE NOTES: 1,2,3,4,7,8,9
DOWNFLOW
A02060
A02063
A02062
A02061
DOWNFLOW
VENTING NOTES
1. For common vent, vent connector sizing and vent material: United States, latest edition of the National Fuel Gas Code (NFGC), ANSI
Z223.1/NFPA 54.
2. Immediately increase to 5-in. (127 min) vent connector outside furnace casing when 5-in. (127 min) vent connector required, refer to Note 1.
3. Side outlet vent for upflow and downflow installations must use Type B vent immediately after exiting the furnace, except when Downflow Vent
Guard is used in downflow position.
4. Type B vent where required, refer to Note 1.
5. 4-in. (102 min) single wall vent must be used inside furnace casing and the Downflow Vent Guard Kit.
6. Accessory Downflow Vent Guard Kit required in downflow installations with bottom vent configuration.
7. Chimney Adapter Kit required for exterior masonry chimney applications. Refer to Chimney Adapter Kits for sizing and complete application
details.
8. Secure vent connector to furnace elbow with (2) corrosion -resistant sheet metal screws, space approximately 180 apart.
9. Secure all other single wall vent connector joints with (3) corrosion -resistant screws spaced approximately 120 apart. Secure Type B vent
connectors per vent connector manufacturer's recommendations.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
9
800SA/801SA: Product Data
DIMENSIONS
(aJ.q
a
9
L
M
J If/le 111.11
l If1. 11 ) 111Y A
s vz lel.et
n lD.n uA (Ld —�1 f ve e
pp I II Ia.51
e llle 172111 I 4 K11Uf .1
121 J.51 ACC[SS011
f 111------- MAIN
iSD. tI� _ _ _ _ -
---
_ _ — —_-- I \ u u
21 Jll 1 41ll
I lal. i] I.—SlAt tIAL flill I GAS [IIAI
tOJ (------------•1
�el/e I i z sn1
C LS)OA1 I ISfI
L—_—_—_—_—_ -,
ISIf. SItl011d1 IAA[1 11 ff�11 D JII
to lle MIN 10D14 Ilf.li
lltl. it IDIH
f tJt.fl
Elm
N1'+1YIA C LAIYY
ll
10�1"� Jy
• I
�1 AL1[LtIfC
,f1ClIXAI lot
I
� I
_—_—
t u ve
:
I�Wit', I
IME. S101CSI
1
r17777pJ
Ia01e SIDLSI
7
lif./1
i{Y2.111— fl
DL IYLLt
01.61
A190094
FURNACE SIZE
A
CABINET WIDTH
-
B
OUTLET WIDTH
C I
TOP AND
BOTTOM FLUE
COLLAR
D
BOTTOM
INLET WIDTH
VENT
CONNECTION
SIZE
SHIP WT. LB.
(KG)
36045E14
14-3/16 (360)
12-9/16 (319)
9-5/16 (237)
12-11/16 (322)
4 (102)
104 (47)
36045E17
17-1/2 (445)
15-7/8 (403)
11-9/16 (294)
16 (406)
4 (102)
119 (54)
70E14
14-3/16 (360)
12-9/16 (319)
9-5/16 (237)
12-11/16 (322)
4 (102)
114 (52)
3607OE17
17-1/2 (445)
15-7/8 (403)
11-9/16 (294)
16 (406)
4 (102)
120 (54)
17-1/2 (445)
15-7/8 (403)
11-9/16 (294)
16 (406)
4 (102)
126 (57)
4807OE21
21 (533)
19-3/8 (492)
13-5/16 (338)
19-1/2 (495)
4 (102)
142 (64)
42090E17
17-1/2 (445)
15-7/8 (403)
11-9/16 (294)
16 (406)
4 (102)
131 (49)
4809OE21
21 (533)
19-3/8 (492)
13-5/16 (338)
19-1/2 (495)
4 (102)
137 (62)
6009OE21
21 (533)
19-3/8 (492)
13-5/16 (338)
19-1/2 (495)
4 (102)
140 (64)
60090E24
24-1/2 (622)
22-7/8 (581)
15-1/16 (383)
23 (584)
4 (102)
146 (66)
601IOE21
21 (533)
19-3/8 (492)
13-5/16 (338)
19-1/2 (495)
4 (102)
146 (66)
601IOE24
24-1/2 (622)
22-7/8 (581)
15-1/16 (383)
23 (584)
4 (102)
161 (73)
60135E24
24-1/2 (622)
22-7/8 (581)
15-1/16 (383)
23 (584)
4 (102)
167 (76)
60155E24
24-1/2 (622)
22-7/8 (581)
15-1/16 (383)
23 (584)
4 (102)f
168 (76)
*. 135 and 155 size furnaces require a 5 or 6-in. (127 or 152 mm) vent. Use a vent adapter between furnace and vent stack. See Installation
Instructions for complete installation requirements.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
10
800SA/801SA: Product Data
GUIDE SPECIFICATIONS
Gas Furnace
800SA/801 SA
General
SYSTEM DESCRIPTION
Furnish a fixed capacity gas -fired furnace for use
with natural gas or propane (factory authorized conversion kit required
for propane); furnish cold air return plenum.
QUALITY ASSURANCE
Unit will be designed, tested and constructed to the current ANSI Z
21.47/CSA 2.3 design standard for gas -fired central furnaces.
Unit will be 3rd party certified by CSA to the current ANSI Z
21.47/CSA 2.3 design standard for gas -fired central furnaces.
Unit will carry the CSA Blue Star® label.
Unit efficiency testing will be performed per the current DOE test
procedure as listed in the Federal Register.
Unit will be certified for capacity and efficiency and listed in the latest
AHRI Consumer's Directory of Certified Efficiency Ratings.
Unit shall carry the current Federal Trade Commission Energy Guide
efficiency label.
DELIVERY. STORAGE AND HANDLING
Unit shall be shipped as single package only and is stored and handled
per unit manufacturer's recommendations.
WARRANTY (for inclusion by specifying engineer)
Warranty certificate available upon request.
EQUIPMENT
Components shall include: slow -opening gas valve to reduce ignition
noise, regulate gas flow, with electric switch gas shut-off; flame proving
sensor, hot surface igniter, pressure switch assembly, flame rollout
switch, blower and inducer assembly, 40va transformer; low -voltage
(heating) (heating/cooling) thermostat.
Blower Wheel and Blower Motor
Galvanized blower wheel shall be centrifugal type, statically and
dynamically balanced. Blower motor of fixed -speeds, constant torque
ECM type shall be permanently lubricated with sealed bearings, of
hp, and shall be multiple -speed direct drive. Blower motor shall
be soft mounted to the blower scroll to reduce vibration transmission.
Filters
Furnace may have reusable -type filters. Filter shall be in. (mm)
W in. (mm). An accessory high efficiency Media Filter is
available as an option. Media Filter.
Casing
Casing shall be of .030 in. (.76) thickness minimum, pre -painted steel.
Inducer Motor
Inducer motor shall be soft mounted to reduce vibration transmission.
Draft Safeguard Switch
Draft Safeguard Switch (blocked vent safeguard) shall be factory
installed to reduce the possibility of vent gas infiltration due to a blocked
or restricted vent pipe.
Heat Exchangers
Heat exchangers shall be a 4-Pass 20 gage aluminized steel of
fold -and -crimp sectional design when applied operating under negative
pressure.
Controls
Control shall include a micro -processor based integrated electronic
control board with at least 11 service troubleshooting codes displayed
via enhanced flashing LED diagnostic light on the control, a self -test
feature that checks all major functions of the furnace within one minute,
and a non-volatile memory replaceable automotive -type circuit
protection fuse. Multiple operational settings available including,
separate blower speeds for heating, cooling and continuous fair. Cooling
airflow will be selectable between 350 or 400 CFM per ton of air
conditioning.
OPERATING CHARACTERISTICS
Heating Capacity shall be Btuh input; Btuh output
capacity.
Fuel Gas Efficiency shall be 80% AFUE. Air delivery shall be
CFM minimum at 0.50 In. W.C. external static pressure.
Dimensions shall be: depth in. (turn); width in.
(mm); height in. (min) (casing only). Height shall
be in. (mm) with A/C coil and in. (mm)
overall with plenum.
ELECTRICAL REQUIREMENTS
Electrical supply shall be 115 volts, 60 Hz, single-phase (nominal).
Minimum wire size shall be AWG; maximum fuse size or
circuit breaker shall be Amps.
SPECIAL FEATURES
Refer to section of the product data sheet identifying accessories and
descriptions for specific features and available enhancements.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.