APPROVED BLD-BLD2021-0049+Manufacturer_Specifications_and_Installation_Instructions+1.13.2021_1.58.53_PM+1988354RECEIVED BLD2021-0049 REVIEWED BY Jan 13 2021 CITY OFEDMONDS = CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BUILDING DEPARTMENT 1=17EA&fIffly W MECHANICAL & ELECTRIC 22118 20th Ave. SE Suite 125 Bothell, WA 98021 425-483-3363 1 contact@premierme.net Hamish Anderson Custom Homes, Inc. I Driessen Residence Mechanical Submittal Package I Table of Contents 1. Trane a. Trane Heat Pump — 4TWX8060A b. Trane Furnace — S9X2C100D5PSBA c. Trane Coil — 4TXC-DS 2. Filter a. AprilaireFilter —1510 3. Controls a. Honeywell Thermostat — TH6320U2008 b. Honeywell T6 Pro Catalog c. Honeywell Zone Panel d. Honeywell Dampers e. Honeywell Damper Catalog 4. Fans a. Panasonic Fan — FV-0511VK2 5. Radiant a. Viessmann Vitocell-V 100 b. Viessmann Vitodens 200-W B2HB c. Uponor Tubing Coils — hePEX plus d. Uponor Two -Wire Thermal Actuator e. Uponor Heating Manifold — Wirsbo EP f. Tekmar Thermostat — 522 6. Trim a. Shoemaker Supply Grille — LSW b. Shoemaker Supply Grille — AFP c. Shoemaker Return Grille — 905 PREMIER w MECHANICAL & ELECTRIC 22118 20th Ave. SE Suite 125 Bothell, WA 98021 425-483-3363 1 contact@premierme.net Hamish Anderson Custom Homes, Inc. I Driessen Residence Mechanical Submittal Package 1. Trane a. Trane Heat Pump — 4TWX8060A b. Trane Furnace — S9X2C100D5PSBA c. Trane Coil—4TXC-DS TRAME(R 4TWX806OA-SUB-1 5 Ton Split System Heat Pump —1 Ph NOTE: All dimensions are in mm/inches. 4TWX8060A rt� K ELECTRICAL SERVICE PANEL r :r 28.6 11-II87 DIA. K_0. WITH 22.2 (IIS7 DIA HOLE IN CONTROL BOX BOTTOM FOR ELECTRICAL POWER SUPPLY L IOUID LINE SERVICE- } VALVE, "E" D- FEMALE H BRAZE coNNECT RE WITH II4" SAE FLARE PRESSURE TAP FITTINGS - UNIT SHOULD BE PLACED SO ROSE RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST "' fIP"1 FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED. FIG. 1 K.O. FOR ALTERNATE ELECTRICAL ROUTING GAS LINE 1/4 TURN BALL SERVICE VALVE, "D" I_D. FEMALE BRAZED CONNECTION WITH I/4" SAE FLARE PRESSURE TAP FITTING_ From i D152635 Rev. 16 MODELS BASE A B C D E IFG H J K 4TWX80OA B q 1369 946 870 1 1/8 3/8 152 (6) 98 219 86 730 (53-7/8) (37-1/4) (34-1/4) (3-7/8) (8-5/8) (3-3/8) (28-3/4) Product Specifications OUTDOOR UNIT O® 4TWX806OA1000A POWER CONNS. — V/PH/HZ ® 208/230/1/60 MIN. BRCH. CIR. AMPACITY 39 BR. CIR. PROT. RTG. — MAX. (AMPS) 60 COMPRESSOR CLIMATUFF® - SCROLL NO. USED - NO. STAGES 1-2 VOLTS/PH/HZ 208/230/1 /60 R.L. AMPS O - L.R. AMPS 28.8 - 152.9 FACTORY INSTALLED START COMPONENTS ® NO INSULATION/SOUND BLANKET NO COMPRESSOR HEAT YES OUTDOOR FAN PROPELLER DIA. (IN.) - NO. USED 27.6 - 1 TYPE DRIVE - NO. SPEEDS DIRECT - 1 CFM @ 0.0 IN. W.G. ® 4760 NO. MOTORS - HP 1 - 1/3 MOTOR SPEED R.P.M. 850 VOLTS/PH/HZ 208/230/1 /60 F.L. AMPS 2.80 OUTDOOR COIL —TYPE SPINE FINTNI ROWS - F.P.I. 2 - 24 FACE AREA (SQ. FT.) 29.15 TUBE SIZE (IN.) 3/8 REFRIGERANT CONTROL EEV REFRIGERANT R-410A LBS. — R-410A (O.D. UNIT) © 13 LBS.- 3 OZ. FACTORY SUPPLIED YES LINE SIZE - IN. O.D. GAS © 1-1/8 LINE SIZE - IN. O.D. LIQ. © 3/8 CHARGING SPECIFICATION SUBCOOLING 10°F DIMENSIONS H X W X D CRATED (IN.) 57.4 X 35.1 X 38.7 WEIGHT SHIPPING (LBS.) 361 NET (LBS.) 311 O Certified in accordance with the Air -Source Unitary Air -conditioner Equipment certification program, which is based on ARI standard 210/240. In order to achieve ARI standard rating, the indoor fan time delay on the comfort control must be enabled. ® Rated in accordance with ARI standard 270. ® Calculated in accordance with Natl. Elec. Codes. Use only HACK circuit breakers or fuses. O Standard Air — DryCoil— Outdoor O This value approximate. For more precise value see unit nameplate. © Max. linear length 60 ft.; Max. lift - Suction 25 ft.; Max lift - Liquid 25 ft. For greater length consult refrigerant piping software Pub. No. 32-3312-0' (' denotes latest revision). O This value shown for compressor RLA on the unit nameplate and On this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. O No means no startcomponents.Yesmeansquickstartkitcomponents.PTCmeanspositivetemperaturecoefficient starter. Sound Power Level Model A -Weighted Sound Power Level [dB(A)] Full Octave Sound Power [dB] 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4TWX806OA1 74 58 75 66 68 66 59 55 52 Note: Rated in accordance with AHRI Standard 270-2008 0 2013 Trane Trane www.trane.com Mechanical Specification Options General The 4TWX8 is fully charged from the factory for matched indoor section and up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide se- lection of air handlers and furnace coils that are A.R.I. certified. The unit shall be certified to UL 1995. Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, G60 galvanized steel and painted with a weather -resistant powder paint on all louvers and panels. Cor- rosion and weatherproof CMBP-G30 DuraTuffTm base. Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and high pressure switch. High and low pressure controls are inherent to the compressor. A factory installed liquid line drier is standard. Compressor The Climatuff° 2-stage compressor features internal over temperature and pressure protection and hermetic mo- tor. Other features include discharge refrigerant connections, centrifugal oil pump and modular plugs for electrical connections. Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured, this unit has a cool- ing capability to 55°F. For low ambient cooling below 55° see Application Guide APP-APG013-EN. C us OTWE Intertek 05/13 Trane has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice. Submittal Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTU H Downflow Only S9X2C100D5PSBA Note: Graphics in this document are for representation only. Actual model may differ in appearance. TAG: Drissen Residence Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. July2019 SM2C100D5-SUB-1C-EN ��IngersollRand Downflow Furnace C Size Cabinet Product Specifications MODEL S9X2C100D5PSBA (a) TYPE Downflow RATINGS (b) 1st Stage Input BTUH (ICS) 65,000 1st Stage Capacity BTUH 63,050 2nd Stage Input BTUH 100,000 2nd Stage Capacity BTUH (ICS) (c) (d) 97,000 1st Stage Temp. Rise (Min. -Max.) 25 - 55 2nd Stage Temp. Rise (Min. -Max.) 40 - 70 AFUE (%) 95.0 BLOWER DRIVE DIRECT Diameter— Width (In.) 11 X 10 No. Used 1 Speeds (No.) (e) 9 CFM vs. in. w.g. See Fan Performance Table Motor HP 1 RPM 1075 Volts/Ph/Hz 120 / 1 / 60 FLA 10.6 COMBUSTION FAN — Type Centrifugal Drive — No. Speeds Direct - 2 Motor HP — RPM 3300/2600 Volts/Ph/Hz 120 / 1 / 60 FLA 0.66 FILTER — Furnished? No Type recommended High Velocity Hi Vel. (No.-Size-Thk.) 2 — 16x20 — 1 in. VENT PIPE DIAMETER — Min (in.) M (g) 2 Round HEATEXCHANGER Type — Fired 409 Stainless Steel MODEL S9X2C100D5PSBA (a) — Unfired 29-4C Stainless Steel Gauge (Fired) 20 ORIFICES — Main Nat. Gas Qty. — Drill Size 5 - 45 LP Gas Qty. — Drill Size 5- 56 GAS VALVE Redundant -Two Stage PILOT SAFETY DEVICE Type 120 V SiNi Igniter BURNERS — Type Multiport Inshot Number 5 POWER CONN. — V/Ph/Hz (h) 120 / 1 / 60 Ampacity (In Amps) 14.1 Max. Overcurrent Protection (Amps) 15 PIPE CONN. SIZE (in.) 1/2 DIMENSIONS H x W x D Uncrated (In.) 34 x 21 x 28-3/4 Crated (In.) 35-1/2 x 23 x 30-7/8 WEIGHT Shipping (Lbs.)/Net (Lbs.) 155/145 (a) Meets Energy Star (b) For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level. M Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3. (d) Based on U.S. government standard tests. (e) 9 Speed constant torque ECM blower motor M Refer to the Vent Length Table in the Installer's Guide. (g) All S9X2 furnace models have a vent outlet diameter that equals 2 in. (h) The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. S9X2C100D5-SUB-1 C-EN Airflow tables Furnace Airflow (CFM) Vs. External Static Pressure (in. W.C.) Model Tap 0.1 0.3 0.5 0.7 0.9 1 SUM 1002 823 644 465 285 Watts 103 117 130 144 157 2 SUM 1385 1276 1167 1057 948 Watts 223 243 264 284 304 3 SUM 1527 1430 1333 1236 1139 Watts 286 310 333 357 380 4 SUM 1610 1516 1421 1326 1231 Watts 328 352 377 401 425 S9X1C100D5PSBA 5 SUM 1761 1677 1593 1509 1425 S961C100135PSAA 433 459 486 512 538 S9X2C100D5PSBA Watts 6 SCFM 1861 1783 1706 1628 1551 Watts 492 520 549 577 605 7 SUM 1984 1902 1820 1738 1656 Watts 548 577 606 635 663 8 SUM 2173 2097 2020 1944 1867 Watts 728 760 792 824 856 9 SUM 2342 2269 2196 2123 2050 Watts 945 973 1002 1031 1060 S9X2C100D5-SUB-1 C-EN CFM Versus Temperature Rise Table 1. 2nd Stage Heating Table — Downflow CFM VS. 2ND STAGE TEMPERATURE RISE MODEL 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 S9X2C100D5PSBA 69 64 60 56 53 50 47 45 43 41 Table 2. 1st Stage Heating Table — Downflow CFM VS. 1ST STAGE TEMPERATURE RISE MODEL 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 S9X2C100D5PSBA 53 50 47 45 43 S9X2C100D5-SUB-1 C-EN General Features NATURAL GAS MODELS Central Heating furnace designs are certified by the American Gas Association for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards. SAFE OPERATION The Integrated System Control is a solid state device which continuously monitors for presence of flame when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide additional safety. QUICK HEATING Durable, cycle tested, heavy gauge tubular stainless steel primary heat exchanger quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower, to increase efficiency and provide a positive discharge of gas fumes to the outside. BURNERS Multiport Inshot burners will give years of quiet and efficient service. All models can be converted to L.P. gas with LP conversion kit. INTEGRATED SYSTEM CONTROL Exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains dry contacts for EAC and HUM. ENERGY EFFICIENT OPERATION Furnace is certified by the manufacturer to leak 1 % or less of nominal air conditioning CFM delivered when pressurized to .5" water column with all inlets, outlets, and drains sealed. I_11:1111a4W4:i7 The variable speed blower motor has sufficient airflow for most heating and cooling requirements and will switch from heating to cooling speeds on demand from room thermostat. SECONDARY HEAT EXCHANGER The S-Series furnace has a special type 29- 4CT11 stainless steel secondary heat exchanger to reclaim heat from flue gases which would normally be lost. STYLING Heavy gauge steel and "wrap -around" cabinet construction is used in the cabinet with baked -on enamel finish for strength and beauty. Every orientation has at least two venting options. There are no knockouts on cabinet. FEATURES AND GENERAL OPERATION The S-Series furnace utilizes a Silicon Nitride Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access. a. Low energy power venter b. Vent proving pressure switches. S9X2C100D5-SUB-1 C-EN Features and Benefits UP TO 96.0% AFUE ON S9X2 FURNACE MODELS Meets utility rebates Lowers utility bills ELECTRICALLY EFFICIENT Efficient airflow design reduces electrical energy use 34 INCH TALL Lighter, easier to move and fit into tight spaces like short basements or tight closets Works great with larger, high -efficiency coils No knockouts 3—WAY MULTI -POISE / DEDICATED DOWNFLOW 11 SKU's — Upflow /Horizontal Left / Horizontal Right 5 SKU's — Downflow Added application flexibility and reduction in specification errors AIRFLOW At least 400 CFM/ton at 0.5 in. H2O external static pressure; setup airflow options down to 290 CFM/ton REGULATORY All models are airtight; 1% or less air leakage as per ASHRAE 193 Open vestibule design provides a full 34" high open vestibule 911u1:1►69us] 6*1 Widths are industry standard: 17.5", 21 ", and 24.5" Depth remains approximately 28" Cabinet will be compatible with industry standard coils, as well as, other accessories INTEGRATED FURNACE CONTROL Setup / Status / Diagnostics / Digital Display No dip switches Last six errors stored Dry contact EAC and HUM connections All Molex connections; no spade terminals Low voltage labeled above and below Rain shield over IFC keeps condensate off the control TUBULAR STAINLESS STEEL PRIMARY HEAT EXCHANGER 29-4C STAINLESS STEEL SECONDARY HEAT EXCHANGER Stainless steel is a more durable, corrosive -resistant material than aluminumized steel Integrated rail system for easy access if required Reduces or eliminates need for baffles VORTICA 11 BLOWER, DESIGNED EXCLUSIVELY FOR THE S-SERIES FURNACE Improved airflow efficiency Durable, easy to clean, two piece housing Single piece belly band/ motor arm assembly Blower deck has full-length rails for easy removal and replacement, regardless of poise THREE—WAY MULTI -POISE (UPFLOW, HORIZONTAL LEFT AND RIGHT) PLUS DEDICATED DOWNFLOW Easier to specify Shipped ready to install (no conversion kits required) Every model has at least two venting options When in horizontal, trap extends only about 2" Barbed fitting on trap at hose connection and on cabinet transition for hose has barbed fitting and clamps at both ends for leak resistance. Vent table improvements including longer vent lengths; 2" pipe can be used up to 100K SM2C100D5-SUB-1 C-EN 7 4j:Pingersoll Rand© Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands — including Club CarT), Ingersoll RandID, Thermo Kingg and Trane®—work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and efficiency. We are a global business committed to a world of sustainable progress and enduring results. 0GiV Ingersoll Rand T. THERMO KING 0 TRANE® ingersollrand.com c0%�us Intertek Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. S9X2C100D5-SUB-1C-EN 31 Ju12019 Supersedes SMM00135-SUB-113-EN (July 2018) ©2016Ingersoll Rand 4TXC-DS-SUB-1 B U TAG: Driessen Residence 1-1/2 - 5 ton ComfortTM Coils, Split System Aluminum Heat Pump / Cooling Coils Cased Upflow/Downflow Horizontal 4TXC-DS Series Coils Outline Drawing for models: 4TXCA002DS3, 4TXCA032DS3, 4TXCB003DS3*, 4TXCB004DS3, 4TXCC005DS3, 4TXCB006DS3, 4TXCC007DS3, 4TXCD008DS3*,4TXCC009DS3,4TXCD010DS3* I� p � � 1 2-114 I o0 FIGURE A 2-1/4 * Connection locations will vary from Outline drawing From Dwg. D345686 RevD MODEL 4TXCA002DS3 4TXCA032DS3 4TXCB003DS3 4TXCB004DS3 4TXCC005DS3 4TXCB006DS3 4TXCC007DS3 4TXCC009DS3 4TXCD008DS3 4TXCD010DS3 WEIGHT (LBS.) 42 46 50 58 60 65 69 78 72 81 REFRIGERANT CONTROL TXV (NON -BLEED) HEIGHT "A" (IN.) 17-1/2 22-1/2 17-1/2 22-1/2 22-1/2 26-7/8 26-7/8 30-3/4 26-7/8 1 30-11/16 OVERALL WIDTH "B" (IN.) 14-1/2 14-1/2 17-1/2 17-1/2 21 17-1 /2 21 21 2423-5/-1/2 24-1/2 OPENING WIDTH "C" IN. 13-5/8 13-5/8 16-5/8 16-5/8 20-1/8 16-5/8 20-1/8 20-1/8 8 23-5/8 TOP OPENING "D" 12-3/4 12-3/4 15-3/4 15-3/4 19-1/4 15-3/4 19-1/4 19-1/4 22-3/4 22-3/4 GAS CONNECTION 3/4 7/8 LIQUID CONNECTION 3/8 MATCHED FURNACE WIDTH (NO ADAPTER REQUIRED) 14 1/2 14 1/2 17 1/2 17 1/2 21 17 1/2 21 21 24 1/2 24 1/2 DRAIN PAN PLASTIC 0 2019 Ingersoll Rand All Rights Reserved Installer's Guide PRODUCT SPECIFICATIONS --- SPLIT SYSTEM HEAT PUMP / COOLING COMFORT TM COILS CASED UPFLOW / DOWNFLOW / HORIZONTAL 4TXCA002DS3HCA 4TXCA032DS3HCA 4TXCB003DS3HCA 4TXCB004DS3HCA 4TXCB006DS3HCA INDOOR COIL -- Type PLATE FIN PLATE FIN PLATE FIN PLATE FIN PLATE FIN Cooling Capacity (Tons) 1.5 - 2.0 1.5 - 3.0 1.5 - 3.0 2.0 - 3.5 2.0 - 4.0 Rows/F.P.I. 2/20 2/20 3/14 3/12 3/14 Face Area (sq.ft.) 3.00 4.5 3.50 5.00 6.00 Tube Size 3/8 3/8 3/8 3/8 3/8 Refrigerant Control (No Non -Bleed TXV Non -Bleed TXV Non -Bleed TXV Non -Bleed TXV Non -Bleed TXV internal check valve) Drain Conn. Size (in.) 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Duct Connections See Outline Drawing See Outline Drawing See Outline Drawing See Outline Drawing See Outline Drawing REFRIGERANT R-410A R-410A R-410A R-410A R-410A CONNECTIONS BRAZED BRAZED BRAZED BRAZED BRAZED Line Size Gas (in.) 3/4 3/4 3/4 7/8 7/8 Line Size Liquid (in.) 3/8 3/8 3/8 3/8 3/8 DIMENSIONS (in.) H X W X D H X W X D H X W X D H X W X D H X W X D Crated (H x W x D) 21-3/8 x 17-1/2 x 26-1/2 26'3/8 x 17-1/2 x 26-1/2 21-3/8 x 20-1/2 x 26-1/2 26-3/8 x 20-1/2 x 26-1/2 30-5/8 x 20-1/2 x 26-1/2 Uncrated 17-5/8 x 14-1/2 x 21-1/2 22-5/8 x 14-1/2 x 21-1/2 17-5/8 x 17-1/2 x 21-1/2 22-5/8 x 17-1/2 x 21-1/2 26-7/8 x 17-1/2 x 21-1/2 WEIGHT (Ibs) 42 / 34 46 / 38 50 / 42 58 / 50 60 / 52 Shipping -- Net 4TXCC005DS3HCA 4TXCC007DS3HCA 4TXCD008DS3HCA 4TXCC009DS3HCA 4TXCD010DS3HCA INDOOR COIL --Type PLATE FIN PLATE FIN PLATE FIN PLATE FIN PLATE FIN Cooling Capacity (Tons) 2..0 - 4.0 3.0 - 5.0 3.0 - 5.0 3.5 - 5.0 3.5 - 5.0 Rows/F.P.I. 3/12 3/14 3/14 3/16 3/16 Face Area (sq.ft.) 5.00 6.00 6.00 7.00 7.00 Tube Size 3/8 3/8 3/8 3/8 3/8 Refrigerant Control (No Non -Bleed TXV Non -Bleed TXV Non -Bleed TXV Non -Bleed TXV Non -Bleed TXV internal check valve) Drain Conn. Size (in.) 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Duct Connections See Outline Drawing See Outline Drawing See Outline Drawing See Outline Drawing See Outline Drawing REFRIGERANT R-410A R-410A R-410A R-410A R-410A CONNECTIONS BRAZED BRAZED BRAZED BRAZED BRAZED Line Size Gas (in.) 7/8 7/8 7/8 7/8 7/8 Line Size Liquid (in.) 3/8 3/8 3/8 3/8 3/8 DIMENSIONS (in.) H X W X D H X W X D H X W X D H X W X D H X W X D Crated (H x W x D) 26-3/8 x 24 x 26-1/2 30-5/8 x 24 x 26-1/2 30-5/8 x 27-1/2 x 26-1/2 34-1/2 x 24 x 26-1/2 34-1/2 x 27-1/2 x 26-1/2 Uncrated 22-5/8 x 21 x 21-1/2 26-7/8 x 21 x 21-1/2 26-7/8 x 24-1/2 x 21-1/2 30-5/8 x 21 x 21-1/2 30-3/4 x 24-1/2 x 21-1/2 WEIGHT (Ibs) 65 / 57 69 / 61 72 / 64 78 / 70 81 / 73 Shipping -- Net [1] These indoor coils are A.H.R.I. certified with various split system air conditioners and heat pumps (A.H.R.I. Standard 210/240). Refer to the Split System Outdoor product information site or www.ahrinet.org 2 4TXC-DS-SUB-1 B Installer's Guide Mechanical Specifications General These coils are A.R.I. certified with Ingersoll Upflow, Downflow, or Horizontal coils shall be designed for cooling and heat Rand's matching condensing units. pump applications. The coil shall be 3/8" seamless aluminum tubing me- Accessories chanically bonded to aluminum plate fin. Refrigerant for the 4TXC-DS coils shall be controlled with factory installed Evaporator Defrost Control installed on coil for Non -Bleed TXV refrigerant control. Refrigerant connections are brazed fit- lower ambient operating conditions. tings with an additional Schrader Valve for system service. The coil cabinet shall have a removable front and interior access panel for evaporator coil entering air surface cleaning. The coil includes a drain pan with drain connections for vertical or horizontal operation and a horizontal auxiliary drain pan. PRESSURE DROP CHARACTERISTICS FOR COOLING AND HEAT PUMP COILS AIRFLOW (CFM) VS. PRESSURE DROP PRESSURE DROP (INCHES OF WATER COLUMN) Model .05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 4TXCA002DS3HCA 225 340 430 510 585 650 715 775 4TXCA032DS3HCA 375 570 725 860 985 1100 1200 1305 4TXCB004DS3HCA 440 655 825 970 1100 1220 1330 1435 4TXCB003DS3HCA 350 525 665 790 900 1000 1095 1180 4TXCB006DS3HCA 430 640 815 965 1095 1220 1335 1445 4TXCC005DS3HCA 520 770 970 1145 1300 1440 1570 1695 4TXCC007DS3HCA 505 760 965 1140 1300 1445 1580 1710 4TXCD008DS3HCA 580 870 1100 1 1300 1 1485 1 1650 1805 1 1950 4TXCD010DS3HCA 555 835 1065 1 1265 1 1445 1 1615 1770 1 1915 4TXC-DS-SUB-1 B Since the manufacturer has a policy of continuous product and product data improvement, it reserves the right to change specifica- tions and design without notice. Ingersoll Rand cOTus 6200 Troup Highway Tyler, TX 75707 Intertek Library Unitary Product Section Coils Product Coil Model 4TXC-DS Literature Type Submittal Date 03/19 File No. 4TXC-DS-SUB-1 B Supersedes 4TXC-DS-SUB-1A PREMIER w MECHANICAL & ELECTRIC 22118 20th Ave. SE Suite 125 Bothell, WA 98021 425-483-3363 1 contact@premierme.net Hamish Anderson Custom Homes, Inc. I Driessen Residence Mechanical Submittal Package 2. Filter a. Aprilaire Filter —1510 Cabinet Features • Model 1510 is a whole home air cleaner designed for low static pressure on larger residential HVAC installations, including Geo-Thermal Systems. • Unit operation is completely silent. • Only maintenance required is replacement of the disposable media. • Outer housing is heavy gauge, preassembled galvanized steel. • Self -aligning painted door easily snaps into place every time. • Warranted for five (5) years from the date of installation to be free from defects in materials or workmanship. Media is disposable and does not apply to warranty. • UL Listed • Narrow 6.75" cabinet for easier installations and more flexible applications. Aprilaire High Efficiency Replacement Media Features • Patented SelfSealTm dramatically reduces air bypass, improving media performance. • Collapsible media with self spacing pleats installs in seconds. • Exclusive media design protects your replacement media business. • Media replacement is recommended after one year. Model 510 • MERV 11 media permanently traps up to 85% of pollen -sized particles (5.0 microns). • MERV 11 media permanently traps up to 80% of mold and spore -sized particles (3.0 microns). • MERV 11 media permanently traps 50% of respirable dust particles (1.0 to 3.0 microns). Model 513 • MERV 13 media permanently traps over 90% of pollen, mold and spore sized particles (3.0 to 10.0 microns). • MERV 13 media permanently traps over 90% of respirable dust and pet dander sized particles (1.0 to 3.0 microns). • MERV 13 media permanently traps up to 75% of bacteria sized particles 0 to 1 micron). 1510 UNITS REPLACEMENT MEDIA Shipping Weight Nominal Size Resistance @ Airflow Volume (inches w.c. @CFM) Shipping Weight (full carton) Filtering Media Area .12"@2200 o Ln .04"@1000 .05"@1200 .14"@2400 .06"@1400 .15"@2600 36.1 lbs. 43.5 sq. ft. w .07"@1600 .17"@2800 c LU g - .09"@1800 .19"@3000 LO .10"@2000 d 23.3 lbs. 31" x 28" o .05"@1000 .15"@2200 Ln .07"@1200 .17"@2400 08"@1400 .18"@2600 36.1 lbs. 43.5 sq. ft. w .10"@1600 .20"@2800 c LU g - .11 "@1800 .23"@3000 .13"@2000 �rfiairee) APRILAIRE MODEL 1510 MEDIA AIR CLEANER Outlet Side Furnace Connection Front withE Edoor C. i i Inlet Side Return Duct Connection Dimension Description Model 1510 A Outlet Opening Height 28.73" (730mm) B Outer Housing Depth Without Door 28.05" (712mm) C Outlet Opening Width 23.88" (607mm) D Unit Width 6.75" (171mm) E Outer Housing Depth With Door 30.06" (763mm) F Inlet Opening Width 23.88" (606mm) G Inlet Opening Height 28.73" (730mm) H Unit Height 31.01" (788mm) Clean Air Dirt Pet Dander Allergens Chemicals Pollen REPLACEMENT MEDIA MODEL 1510 APRILAIRE PART # 510 MERV 11 APRILAIRE PART # 513 MERV 13 **:* APRILAIRE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE. MADE�N PO Box 1467 • Madison, WI 53701-1467 • Phone 800/334-6011 • Fax 608/257-4357 • www.aprilairepartners.com Form No. 2383 6.13 ©2013 Aprilaire —A division of Research Products Corporation PREMIER W MECHANICAL & ELECTRIC 22118 20th Ave. SE Suite 125 Bothell, WA 98021 425-483-3363 1 contact@premierme.net Hamish Anderson Custom Homes, Inc. I Driessen Residence Mechanical Submittal Package 3. Controls a. Honeywell Thermostat — TH6320U2008 b. Honeywell T6 Pro Catalog c. Honeywell Zone Panel d. Honeywell Dampers e. Honeywell Damper Catalog Honeywell T6 Pro Series Thermostats I SUBMITTAL SHEET Job Name Engineer Mechanical Contractor Contractor's P.O. No. Representative Notes APPLICATION ModelTH6320U2008: Up to 3H/2C Heat Pump systems or up to 2H/2C Conventional systems. DuaIf uel and aux heat lockout with outdoor sensor. ModelTH6220U2000: Up to 2H/1C Heat Pump systems or up to 2H/2C Conventional systems. Dual fuel and aux heat lockout with outdoor sensor. ModelTH6210U2001: Up to 2H/1C Heat Pump systems or up to 1H/1C Conventional systems. No outdoor temperature lockouts. SPECIFICATIONS Terminal Designations: R, RC, C, W, 0/B, W2-AUX, E, Y, Y2, G, L/A, K, S, and S. Electrical Ratings: Terminal Voltage (50/601-14 Running Current W Heating 20-30 Vac 0.02-1.0 A W Heating 750 mV DC 100 mA DC W2 (Aux) Heating 20-30 Vac 0.02-1.0 A E Emergency Heat 20-30 Vac 0.02-0.5 A Y Compressor Stage 1 20-30 Vac 0.02-1.0 A Y2 Compressor Stage 2 20-30 Vac 0.02-1.0 A G Fan 20-30 Vac 0.02-0.5 A O/B Changeover 20-30 Vac 0.02-0.5 A L/A Input 20-30 Vac 0.02-0.5 A Model(s) TH621OU2001 Qty. Notes TH6220U2000 Q Notes TH6320U2008 Q Notes Approval Service Tag No. Power Consumption: Backlight On: 1.OVA Cool Indication: Displays "Cool On" when the thermostat turns the cooling on. Heat Indication: Displays "Heat On" when the thermostat turns the heating on. Clock Accuracy: +/-1 minute every month (30 days) at 77°F. +/-2 minutes per month over the operating ambient temperature range. Mounting Means: Thermostat packaged with a UWPTM mounting system that mounts directly on the wall in the living space using mounting screws and anchors provided. Use the cover plate (also included with thermostat) and its mounting bracket to mount the thermostat onto a vertical 2 x 4 in. junction box. Temperature Ranges: Heating: 40 IF to 90 IF (4.5 °C to 32 IC) Cooling: 50 IF to 99 IF (10 °C to 37 °C) Operating Ambient Temperature: 37 IF to 102 IF (2.8 °C to 38.9 IC) Shipping Temperature: -20 IF to 120 IF (-28.9 °C to 48.9 IC) Operating Relative Humidity: 5% to 90% (non -condensing) Physical Dimensions: 4-1/16" H x 4-1/16" W x 1-5/32" D 103.5 mm H x 103.5 mm W x 29 mm D Color: White 11111111111111111111111111 Product Part Number Temperature Setpoint Range Working Ambient Temperature Operating Relative Humidity Shipping Temperature Physical Dimensions in Inches (mm) Color(s) Heating: 40 OF to 90 OF TH621OU2001 (4.5 °C to 32 °C) 32 OFto 120 OF 5% to 90% -20 OF to 120 OF 4-1/16" H x 4-1/16"W x 1-5/32" D Thermostat TH6220U2000 (0 Coto 48.9 °C) (non condensing) g (-28.9 °C to 48.9 °C) 103.5 mm H x 103.5 mm W x 29 mm D White TH6320U2008 Cooling: 50 °Fto 99 OF (10 °C to 37 °C) Product Part Number Physical Dimensions in Inches (mm) UWP Wall plate Included with thermostat. 2.67" H X 2.28" W X 0.41" D (67.9 mm H X 58 mm W X 10.3 mm D) J-Box adaptor plate Included with thermostat. 3.91" H X 3.91" W X 0.66" D (99.4 mm H X 99.4 mm W X 16.7 mm D) Small cover plate Included with thermostat. 4.76" H X 4.76" W X 0.35" D (121 mm H X 121 mm W X 8.9 mm D) Large cover plate Optional accessory. Not included with thermostat. 6.11" H X 6.11" W X 0.28" D (155.3mmHX155.3mmWX7mmD) Wired outdoor sensor Not included with thermostat. Used for dual fuel or aux heat lockout only. Outdoor temp not C70891-11006 displayed on thermostat. Not compatible with TH621OU model. Wired indoor sensor Not included with thermostat. Not compatible with TH621OU model. — C71891-11005 DIMENSIONS (NOT TO SCALE) Thermostat Front Thermostat Side 4.08" (103.6 mm) erosa,�a: 4.08" 1.06" - (103.6 mm) (27 mm) Small Cover Plate mm) Y 0.35" (8.9 mr 76" (121 mm) Home and Building Technologies 4L 0.66 (16.7 mm) UWPTM M mm) J-box Adapter — 3.91" (99.4 mm) In the U.S.: Honeywell ® U.S. Registered Trademark 1985 Douglas Drive North © 2017 Honeywell International Inc. Golden Valley, MN 55422-3992 33-00263-01 M.S. 01-17 customer.honeywell.com Printed in United States mm) Honeywell THE POWER OF CONNECTED Home F" Introducing THE NEW STANDARD FOR SIMPLE ........................... . . . . . . . . . . . . . . . . . . . . . . . . . . . ---------------- Honeywell . .. UJUPH Heat I� ...... I l� Heaton �I I I M� i Menu . . . ■ . ■..........................................................: Following Schedule • Mode Menu T6 Pro Hydronic Honeywell 53UPM L Fan Auto Heat _ I I� Mode Menu Fan V % %W %W V T6 Pro The Honeywell T Series is a portfolio of non -connected and Wi-Fi connected thermostats designed with contractors in mind. With an interface you know, features you trust and the Honeywell quality you depend on in a sleek new aesthetic, the non -connected T Series thermostats are setting the new standard for simple. Mode Menu Fart . . . ■ • e PrcSeries ; T4 Pro Honeywell T Series NON -CONNECTED SOLUTIONS that simplify selection, installation and upsell. Simple selection We've streamlined our legacy portfolio of 20+ non -connected FocusPRO° and PRO thermostats down to just eight non -connected T Series thermostats, helping you simplify inventory management and product selection. Simple installation All T Series thermostats use the same UWP mounting system, helping you standardize your training program, install process and truck stock. Install one and you can install them all. ... :OWP ::nponting • • • • system Simple upsell ' ..::::: ' The T Series features a snap -together design that enables you to easily move customers from a non -connected to a connected thermostatwhen they're ready for Wi-Fi —without having to remove the connector and cover plate.* ThermostatWired Thermostat Program •• • . i d•• Replaces this ••r options method outdoor•O or sensors•O model 12 T6 Pro Hydronic 7-day, 5-2, 5-1-1 or Battery or 5.44sq.in 1Heatonly No Yes. Floor or indoor air No TH114-AF-024T TH6100AF2004 non -programmable C-wire only. TH115-AF-024T Yes. Outdoor 02-- T6 Pro 7-day, 5-2, 5-1-1 or Battery or 5.44sq. in. 3H/2C Heat Pump+ Yes sensorfor Yes TH6320U1000 TH6320U2008 non -programmable C-wire 2H/2CConventional lockouts only. TH5320U1001 - No display. _ Yes. Outdoor TH6220D1028 T6 Pro 7-day, 5-2, 5-1-1 or Battery or 5.44 sq. in. 2H/1C Heat Pump+ Yes sensor for Yes TH6220D1002 TH6220U2000 non -programmable C-wire 2H/2CConventional lockouts only. TH5220D1029 - No display. TH5220D1003 TH611 -12 T6 Pro 7-day,5-2, 5-1-1 or Batter or y 5.44sq.in. 2H/1C Heat Pump+ No No Yes TH611OD10D1005 TH621OU2001 non -programmable C-wire 1H/1CConventional TH421OD1005 - TH3210D1OO4 TH2210DV1006 — - T4 Pro 7-day, 5-2, 5-1-1 or Battery or 3.93 sq. in. 2H/1C Heat Pump+ No No Yes TH2210DH1000 TH1210DV1007 I� TH421OU2002 non -programmable C-wire 1H/1C Conventional TH121ODH1001 TH5110D1022 T4 Pro 7-day, 5-2, 5-1-1 or Batter or 1H/1C Heat Pump + TH511OD1006 TH411OU2005 non programmable C-wire 3.93 sq. in. 1H/1C Conventional No No Yes TH4110D1007 TH2110DV1008 - TH211ODH1002 12 T1 Pro Battery or 1H/1C Heat Pump TH11ODH1003 TH1110D2009 Non -programmable C wire 2.37 sq. in. 1H/1C Conventional No No No TH110DV1009 TH311OD1008 - i2 T1 Pro Non -programmable Battery or 2.3 7 sq. in. 1 Heat or 1 Cool only No No No TH110ODH1004 -- TH101OD2000 C-wireTH1100DV1000 For more information 800-468-1502 forwa rdthi nking.honeywell.com Home and Building Technologies 715 Peachtree Street NE Atlanta, GA 30308 www.honeywell.com *C-wire required 03-00307 1 PM 1 07/18 9 2018 Honeywell International Inc. Honeywell Honeywell HZ322 TrueZONE@ Panel APPLICATION The HZ322 TrueZONE® panel controls: • Conventional gas, oil, or electric forced -air systems up to 2 stages heat and cool; • Heat pump systems with single stage compressor and auxiliary heat; • 2 or 3 forced -air zones.with wired thermostats, or wireless thermostats using optional wireless adaptor. SUBMITTAL SHEET FEATURES • Intuitive installer setup with easy -to -follow, digital display uses real language to guide installer through configuration • Universal application for any HVAC system using conventional thermostat wiring (R W Y G C etc.) • Standard checkout procedure ensures correct operation before leaving the job • Robust push terminals for up to two wires per terminal • Common-sense LEDs indicate stage of heat and damper state • Control of two or three wire dampers with open or closed logic • Variable -speed fan control lowers fan speed when one zone is calling for cooling • Discharge air temperature staging down -stages equipment when near high or low limit 111111111111111111111111 68-3072-01 HZ322 TRUEZONE® ZONE PANEL SPECIFICATIONS Input Ratings: Voltage: 18-30 VAC 50/60 Hz powered by a transformer of 40 VA or more Current Draw: Zone Panel: 7.5 VA max. All VA specifications at 24 VAC. Wiring: 18- or 20-gauge solid (not stranded) wire Humidity Ratings: 5% to 90% RH non -condensing Temperature Ratings: Shipping: -20' to 150°F (-29° to 66°C) Operating: -40' to 165°F (40° to 74°C) Dimensions: See Fig. 1. Mounting: Mounts with either 2 user -supplied screws at center line to mount onto 2 x 4, or with 4 screws at corners for wall mount. Recommended Thermostats: See Table 1. Recommended Dampers: See Tables 2 and 3. For maximum number of dampers per zone see Table 4 Accessories: See Table 5. Emissions: Complies with FCC Class B, part 15 requirements. 11.5 (292) Honeywell 1.0 8(203) 1.8 M28011 Fig. 1. HZ322 TrueZONE panel dimensions in in. (mm). Table 1. Recommended thermostats. System Non -programmable Programmable Single -Stage TH5110D, TH3110D, T87N TH8110U, TH611 OD, TH411 OD Multi -Stage TH5220D TH8320U, TH8321 U, TH6220D, YTH9421 C Heat -Pump TH5220D (2H/1 C only), TH3210D (2H/1 C only) TH8320U, TH8321 U, TH6220D (2H/1 C only), TH421 OD (2H/1 C only), YTH9421 C Wireless TH5320R* TH6320R* Commercial TH7220U, TH8220U Note: All versions of the model numbers listed above will work with the applications they are listed for. *Wireless adaptor required when used with wireless thermostats. 68-3072-01 2 HZ322 TRUEZONE® ZONE PANEL Table 2. Recommended residential dampers. Type Actuation Round Rectangular Zone Spring-open/power-closed ARD ZD Power-open/power-closed RRD Bypass Barometric SPRD SPRD Table 3. Recommended commercial dampers. Type Actuation Round Rectangular Zone Power-open/power-closed MARD D2 with ML6161A2009* Bypass Power-open/power-closed MARD with SPC D2 with ML6161A2009* and SPC *Or equivalent damper and actuator. Table 4. Maximum dampers*. Maximum Damper VA Ambient Temp. per Zone 100°F (38°C) 28.8 160°F (71 °C) 16.8 * Use an SDCR (Slave Damper Control Relay) for additional dampers. • Maximum dampers per panel is limited by transformer size. • Ensure transformer is large enough to power the panel (7.5 VA) and dampers. Table 5. Accessories. Description Part Number 40 VA transformer AT140A1042*t 75 VA transformer AT175A1008 Discharge air temperature sensor (DATS) C7735A1000*t Wireless adaptor THM4000R1000t Slave damper control relay SDCR *Included in HZ322K kit. tlncluded in YHZ322 kits. 68-3072-01 Honeywell ARD and EARD Series Damper Job Name Engineer Mechanical Contractor Contractor's P.O. No. Representative Notes APPLICATION The ARD is a power close and spring open zone damper. It has a 24-volt motor used to control circulating air in HVAC systems and is used when normally -open damper is required. The ARD is typically used with Honeywell TrueZONE electronic zoning systems and others. The EARD is a power open and spring closed fresh air damper. It has a 24-volt motor used to control circulating air in fresh air ventilation. The EARD is typically controlled by an IAQ thermostat or other whole house ventilation control. ARD AND EARD FEATURES ARD Features • Adjustable close position range stops. • Shipped as power closed/spring return open damper. • Available in 5 to 10 inch, 12, 14, 16, 18, and 20 inch diameter sizes. • Male (crimped) and female (uncrimped) ends to connect to any rigid or flexible round duct. • Rated to operate up to 1 in. wc. • Blade closes off tightly against gasket for minimal leakage. • Fail-safe, normally open operation. • Simple, easy -to -wire, two -wire (M1 and M6) installation. Optional third wire (M4) powers LED in open position only (does not power motor). EARD Features • Adjustable open position range stops. • Shipped as power open/spring return closed damper. • Available in 5 to 8 inch diameter sizes. • Blade closes off tightly against gasket for minimal leakage. • Galvanized steel damper construction. • Rated to operate up to 1 in. wc. • Simple, easy -to -wire, two -wire installation. • Male (crimped) and female (uncrimped) ends to connect to any rigid or flexible round duct. SUBMITTAL SHEET Model(s) Qt . Notes Qty. Notes Qt . Notes Approval Service Tag No. SPECIFICATIONS IMPORTANT The specifications given in this publication do not include normal manufacturing tolerances. Therefore, this unit may not exactly match the listed specifications. Also, this product is tested and calibrated under closely controlled conditions, and some minor differences in performance can be expected if those conditions are changed. Motor Electrical Rating: 24 Vac, 60 Hz, 8VA. Motor Electrical Connection: Push terminals. Solid (not stranded) wire is recommend. Motor Nominal Angular Rotation: 901. Motor Torque: Minimum 71 in.-oz. (500 millinewton meters) output torque available when motor is energized and device is at the spring return initial start position. Nominal Motor Timing at 77r1F (25rsC) Ambient: Energized at rated load: 30 seconds. De -energized (spring return): 10 seconds. Motor Ambient Temperature Rating: 40 to 140F (5 to 60C). Leakage: Less than 1% at 1/2 in. wc. Pressure Drop: Maximum at full open: 0.0329 in. we at 800 ft/min. Maximum Static Pressure: 1 in. we for all models. Motor Shaft Rotation Direction: Clockwise, when energized and viewed from the base or shaft end. Motor Mounting Means: Direct connection to damper shaft. Motor Mounting Position: Multi -poise. Construction ARD Dampers Frame: Galvanized steel spiral duct, crimped on downstream side. ARD Sizes: 5 to 10 inch, 12, 14, 16, 18, and 20 inch diameter. Gauge: ARD5-ARD12: 24 gauge frame, and 22 gauge blade. Blade: ARD14-ARD20: 22 gauge frame, and 20 gauge blade. EARD Dampers Frame: Galvanized steel spiral duct. EARD Sizes: 5 to 8 inch diameter. REPLACEMENT PARTS Actuator assembly: ARD: M847D-ZONE EARD: M847D-VENT 11111111111111111111111111 33-00265-01 Table 1. ARD models. ARD models ARD5TZ ARD6TZ ARD7TZ ARD8TZ ARD9TZ ARD10TZ ARD12TZ ARD14TZ ARD16TZ ARD18TZ ARD20TZ Table 2. EARD models. EARD models EARD 5TZ EAR D6TZ EARD 7TZ EARD 8TZ Damper dimensions: ARD and EARD dampers are all approx.2" longerthan the damper diameter. Damper diameter is the number listed after ARD. (Example ARD8TZ is 8" diameter). Home and Building Technologies In the U.S.: Honeywell 1985 Douglas Drive North Golden Valley, MN 55422-3992 customer.honeywell.com Table 3. Approximate ARD/EARD Bleed Rate. Range stop setting Bleed Rate 0 Closed 1 16% 2 30% 3 50% ® U.S. Registered Trademark © 2017 Honeywell International Inc. 33-00265-01 M.S.01-17 Printed in United States Dimensions in inches (mm). 64 3) TrueZONE° Damper Honeywell The next generation of dampers are here. The Honeywell TrueZONE Damper is a direct replacement for today's legacy dampers, and the intuitive design speeds installation and checkout with less troubleshooting. Plus, the TrueZONE Damper is built to last, greatly reducing callbacks. It's backed by a 5-year warranty, so you can install it with confidence on every job. THERMOSTATS I ZONING I AIR CLEANERS I HUMIDIFIERS I DEHUMIDIFIERS I UV SYSTEMS I VENTILATION I WATER SOLUTIONS I COMBUSTION Simple, Easy And Effective Control For both zoning and ventilation applications, TrueZONE Dampers are the ideal choice. Installation has been designed with the technician in mind, and the quiet, efficient operation helps ensure satisfied customers for years to come. The TrueZONE Damper is a two -position, 24-VAC, power -close, spring -return damper with a built-in actuator, giving you everything you need in one easy -to -install unit. Two models are available in a variety of sizes. Outstanding Performance TrueZONE Forced TrueZONE Dampers are exactly what you'd expect from Honeywell — s. Air Zoning Damper precision -built for excellent results. This damper was specifically designed with Power closed/spring return ; R8 insulation specification in mind to contribute to energy savings and help the open damper. system pass efficiency audits. Best of all, it helps eliminate hot and cold spots, the biggest cause of callbacks. The improved internal design creates a slower return that ensures a quiet operation. Installation Made Easy TrueZONE Dampers For fast, accurate installation with no callbacks, the TrueZONE Damper has you covered with a range of features that simplify installation in every application: • Adjustable Range Stops — Easy to understand and set by utilizing a push -in lever. They're used to bleed air into the zones which helps lower pressure and reduce noise. • Mechanical Position Indicator — Easy viewing through a clear window. • Push -In Terminals — The same easy wiring design used on TrueZONE Panels. No tools needed, has space for two wires. • LED Indicator Lights — Red indicates the damper is closed and green indicates open (used in 3-wire applications) • Taping Flange — Lets you position insulation under it before sealing with foil tape. Built To Last Install it and forget it. The TrueZONE Damper actuator is constructed with high - temperature outer plastics, an all -metal drive train and Teflon® -coated springs. All parts are backed by a 5-year warranty. Simply put, you're getting a premium product without paying a premium price. Start Today More than 120 variations are available. The most common are listed here. ARD6TZ ARDIOTZ ARD12TZ ARD14TZ ZD10x8TZ ZD12x8TZ I ZD14x8TZ ZD16x8TZ ZD18x8TZ ZD20x8TZ IZD20x10TZ ZD24x8TZ Customers are seeking the comfort and energy savings of zoning. If you already offer ; zoning, use the new TrueZONE Damper _ to save installation time and make more profits per job. If you don't offer zoning, the complete TrueZONE lineup, including the TrueZONE damper, make it an easy choice for growing your bottom line. Also Available TrueZONE Fresh Air Ventilation Damper Power open/spring return closed damper. For more information on Honeywell TrueZONE Dampers, see your distributor or visit www.forwardthinking.honeywell.com. Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 50-1947JJ August 2015 www.honeywell.com 0 2015 Honeywell International Inc. Qf YouTube: @honeywellcpro You= Honeywell PREMIER w MECHANICAL & ELECTRIC 22118 20th Ave. SE Suite 125 Bothell, WA 98021 425-483-3363 1 contact@premierme.net Hamish Anderson Custom Homes, Inc. I Driessen Residence Mechanical Submittal Package 4. Fans a. Panasonic Fan — FV-0511VK2 wh1cz_nerGreen5do-e- - VENTILATION I FAN Specification Submittal Data / Panasonic Ventilation Fan Description Customizable ceiling mount ventilating fan, low sone and rated for continuous operation. ENERGY STAR® rated and certified by the Home Ventilating Institute (HVI). Evaluated by the Underwriters Laboratories and conforms to both UL and cUL standards. Motor/Blower: • Enclosed brushless ECM smart motor technology rated for continuous operation • Adjustable ventilation rates at 50 — 80 —110 CFM • Power rating of 120 volts and 60 Hz • UL and cUL listed for tub/shower enclosure when GFCI protected • Motor equipped with thermal cutoff fuse • Removable permanently lubricated plug-in motor Housing: • Environmentally friendly 26 gauge Zinc -Aluminum -Magnesium (ZAM) housing • Integrated dual 4" or 6" diameter duct adapter • Built-in damper reduces back draft and helps with blower door testing • Built-in metal flange provides blocking for penetrations through drywall as an Air Barrier, and assists with the decrease in leakage in the Building Envelope during blower door testing • Suitable for installation in ceilings insulated up to R60 • Articulating and expandable installation bracket up to 24" Grille: • Attractive design using Poly Pro material • Attaches directly to housing with torsion springs • Includes a motion sensor cap for use as a cover when motion sensor Plug 'n PlayTM module has not been selected Warranty: • ECM Motor: 6 Years from original purchase date • ALL Parts: 3 Years from original purchase date Architectural Specifications: Customizable ceiling mount ventilation fan, ENERGY STAR® rated with built-in speed selector. Select from 50/80/110 CFM with <0.3 sone as certified by the Home Ventilating Institute (HVI) at 0.1 w.g. with 51/80/110 CFM and no more than 0.4/0.5/0.8 sones at 0.25 w.g. and 51 /79/108 CFM at 0.375 w.g. Power Consumption shall be no greater than 9.9/7.9/6.5 watts at 0.1 w.g. and 15.4/13.1/11.2 watts at 0.25 w.g. and 9.6/13.4/20.0 watts at 0.375 w.g. ENERGY STAR® rated with efficiency of no less than 16.2/15.7/11.1 CFM/watt at 0.1 w.g. and 8.3/8.3/7.1 CFM/watt at 0.25 w.g. and 5.3/5.9/5.4 CFM/watt at 0.375 w.g. The motor shall be enclosed with brushless ECM motor engineered to run continuously. ECM motor speed shall automatically increase when the fan senses static pressure to maintain selected CFM. Power rating shall be 120v/60Hz. Duct diameter shall be no less than 4", inclusive of an integrated dual 4" or 6" duct adapter. Plug 'N Play - modules provide up to three additional features. Select from Multi -Speed with Time Delay, Condensation Sensor, and Motion Sensor. Fan shall be RoHS Compliant and UL and cUL listed fortub/shower enclosure when GFCI protected. Also suitable for installation in ceilings insulated up to R60. Fan can be used to comply with ASHRAE 62.2, LEED, ENERGY STAR® IAP, EarthCraft, California Title-24 and WA Ventilation Code. ECM Motor Technology: When fan senses static pressure, its speed is automatically increased to i7vensure that the desired CFM is not compromised, which allows the fan to perform as rated. p. FV-0511 VK2 Built -In Self Adjusting Airflow Capability FV-0511VK2 1 4'' or 6'' duct Model Quantity Comments Project: Location: Architect: Engineer: Contractor: Submitted by: Date: For complete Installation Instructions visit us.panasonic.com/ventfans Ceiling Radiation Damper: WhisperGreen Select'" is UL listed for use with the Panasonic Ceiling Radiation Damper (Model #: PC-RD05C5, sold separately). 0 wh azncrGreel SeCeetFV-0511VK2 � Built -In Self Adjusting VENTILATIONS FAN Airflow Capability Plug 'N Play"' Modules Plug 'N Play" modules provide up to three additional features. Select from Multi -Speed with Time Delay, Motion Sensor, and Condensation Sensor. FV-VS15VK1: Multi -Speed with Time Delay Allows you to select the proper CFM settings to satisfy ASHRAE 62.2 continuous ventilation requirements. The fan runs continuously at a pre-set lower level (0, 30-100 CFM, in 10 CFM increments), then elevates to a maximum level of operation (50-80-110 CFM) when the wall switch is turned on, or when the motion sensor or Condensation Sensor module is activated. A High/Low delay timer returns the fan to the pre-set CFM level after a period of time set by the user. FV-MSVK1: Motion Sensor a Automatically activates when someone enters the room. Once the settings have been applied, the fan becomes truly automatic. This module also activates a 20 minute delay off timer for the fan. FV-CSVK1: Condensation Sensor Helps control bathroom condensation to prevent mold and mildew. Sensor technology detects relative humidity and temperature it to anticipate dew point, automatically turning the fan on to control humidity. Built-in Relative Humidity (RH) sensitivity adjustment enables fine tuning for moist conditions and for satisfying CalGreen requirements. When the condensation sensor is used in conjunction with multi -speed functionality, the fan will kick up to high speed when the condensation sensor detects moisture in the room. This module also activates a 20 minute delay off timer for the fan. Fan Specifications WhisperGreen Select'" r Static Pressure in inches w.g. Air Volume (CFM) 0.1 110 0.25 110 0 108 0.1 80 0.25 80 0 79 0.1 50 0.25 51 0.375 51 Noise (sones) <0.3 0.8 - <0.3 0.5 - <0.3 0.4 - Power Consumption (watts) 9.9 15.4 20.0 5.1 9.6 13.4 3.1 6.2 9.6 Energy Efficiency (CFM/Watt) 11.1 7.1 5.4 15.7 8.3 5.9 16.2 8.3 5.3 Speed (RPM) 920 1182 1356 795 1113 1315 722 1054 1266 Current (amps) 0.10 0.16 0.20 0.06 0.10 0.14 0.04 0.07 0.10 MAX. Current(amps) 0.20 Power Rating (V/Hz) 120/60 ENERGY STAR rated Yes 0.375=Installed Performance Static Pressure in inches w.g. 0.1 0.25 � 0.1 0.25 � 0.1 0.25 � 0.1 0.25 � 0.1 0.25 � 0.1 SpeedModule) 0.25 � 0.1 0.25 � 0.1 0.25 Air Volume (CFM) 110 110 108 100 101 101 90 90 90 80 80 79 70 71 70 60 60 50 51 51 40 41 40 30 30 30 Noise (sones) <0.3 0.8 - <0.3 0.7 - <0.3 0.6 - <0.3 0.5 - <0.3 0.5 - 0.4 - <0.3 0.4 - <0.3 0.3 - <0.3 0.3 - Power Consumption (watts) 9.9 15.4 20.0 7.9 13.1 17.8 6.5 11.2 16.0 5.1 9.6 13.4 4.3 8.5 12.1 6.9 10.5 3.1 6.2 9.6 2.7 5.5 7.8 2.4 4.6 6.8 Energy Efficiency (CFM/Watt) 11.1 7.1 5.4 12.7 7.7 5.7 13.9 8.0 5.6 15.7 8.3 5.9 16.7 8.5 5.9 d7551 8.7 5.7 16.2 8.3 5.3 14.8 7.4 5.1 12.6 6.6 4.4 Speed (RPM) 920 1182 1356 889 1164 1356 839 1135 1351 795 1113 1315 760 1112 13091061 1287 722 1054 1266 707 10571251 711 1039 1259 Current(amps) 0.10 0.16 0.20 0.09 0.14 0.18 0.07 0.12 0.16 0.06 0.10 0.14 0.05 0.09 0.13 0.08 0.11 0.04 0.07 0.10 0.04 0.07 0.09 0.04 0.06 0.08 MAX. Current(amps) 0.20 Power Rating (V/Hz) 120/60 ENERGY STAR rated Yes Panasonic Eco Solutions Company of North America Eco Products Division Two Riverfront Plaza Newark, NJ 07102 us. pan ason i c. com/ventfans MM, us 0.375=Installed Performance r� Most Efficient 2018 w esergvstac9ev Panasonic VF18972SS-FV-0511VK2 PREMIER W MECHANICAL & ELECTRIC 22118 20th Ave. SE Suite 125 Bothell, WA 98021 425-483-3363 1 contact@premierme.net Hamish Anderson Custom Homes, Inc. I Driessen Residence Mechanical Submittal Package 5. Radiant a. Viessmann Vitocell-V 100 b. Viessmann Vitodens 200-W B2HB c. Uponor Tubing Coils — hePEX plus d. Uponor Two -Wire Thermal Actuator e. Uponor Heating Manifold — Wirsbo EP f. Tekmar Thermostat — 522 VI ESMAN N. VITOCELL� 100-V Technical Data Manual Model Nos. and pricing: see Price List Vitocell-V 100 42 to 79 USG / 160 to 300 Itr Product may not be exactly as shown Vitocell 100-V CVA Series Indirect -fired domestic hot water storage tank steel construction, with Ceraprotect two -coat enamel finish S A CERTIFIEDS icp C us NSF/ANSI 372 Indirect -fired domestic hot water storage tank 42 to 119 USG / 160 to 450 Itr Vitocell-V 100 119 USG / 450 Itr 5167 518 - 01 03/2014 Product Information VITOCELL 100-V The vertical tank solution for cost-efficient domestic hot water supply. The Vitocell 100-V DHW tank offers storage capacities of up to 119 USG / 450 Itrs. The benefits at a glance: ■ Corrosion -protected steel tank shell with Ceraprotect two -coat enamel finish. Magnesium anode provides additional cathodic tank protection. ■ Heat exchanger coil extends to the bottom of the tank, thereby heating the entire water content. ■ Extremely convenient domestic hot water supply assured by fast, uniform heating via generously sized heat exchanger surfaces. ■ Certified to CSA Low Lead Content Certification Program; including US Safe Drinking Water Act, NSF/ANSI 372 as well as other applicable US State requirements. ■ Universally suitable - for applications requiring larger quantities of hot water, multiple Vitocell 100-V tanks may be connected to a header to form a tank battery. ■ Increased energy savings thanks to highly effective, foamed -in -place HCFC-free insulation keeping standby losses at a minimum. ■ The vitocell-V 100 119 USG / 450 L capacity tank is supplied with removable soft PET insulation for easier handling. 2 VIESMANN VITOCELL 100-V Product Information Cross -Section VITOCELL 100-V VIESMANN Technical Data Technical Data For domestic hot water heating applications in Suitable for heating systems with conjunction with hot water heating boilers ■ max. working pressure on the heat exchanger side of up to 150 psig / 10 bar ■ max. working pressure on DHW side of up to 150 psig / 10 bar ■ max. supply temperature on the heat exchanger side of up to 230 OF / 110 °C ■ max. DHW supply temperature of up to 150 OF / 65.6 °C Storage Capacity USG 42 53 79 119 Itr 160 200 300 450 Recovery rate* r MBH 136 136 180 238 194 OF with a temperature rise 90 oC GPM 4.3 4.3 5.7 7.6 of the domestic hot Itr/h 982 982 1 302 1 720 water from MBH 109 109 150 198 50 to 113 OF / 176 OF GPM 3.5 3.5 4.8 6.3 10 to 45 °C Itr/h 786 786 1 081 1 425 and boiler water supply temperature of.... at the 158 °F MBH 85 85 113 153 supply flow rate stated 70 °C GPM 2.7 2.7 3.6 4.9 below Itr/h 614 614 811 1 106 140 OF MBH 58 58 78 109 60 o C GPM 1.8 1.8 0.3 3.5 Itr/h 417 417 565 786 122 OF MBH 31 31 61 82 50 °C GPM 1 1 1.9 2.6 Itr/h 221 221 442 589 Recovery rate* MBH 123 123 153 181 194 OF with a temperature rise GPM 2.7 2.7 3.4 4 o of the domestic hot 90 C Itr/h 619 619 774 911 water from MBH 95 95 116 150 50 to 140 OF / 176 OF GPM 2 2 2.6 3.3 10 to 60 IC 80 0Itr/h 482 482 584 756 and boiler water supply temperature of.... at the 158 °F MBH 65 65 78 113 supply flow rate stated 70 °C GPM 1.4 1.4 1.7 2.5 below Itr/h 327 327 395 567 Supply flow rate for the GPM 13.2 13.2 13.2 13.2 recovery rates stated m3/h 3.0 3.0 3.0 3.0 Standby losses *2 MBH/24 h 5.1 5.8 7.5 9.6 Overall dimensions with insulation Width (0) inches 23 23 25 33'/2 mm 581 581 633 850 Depth inches 24 24 273/4 35'/4 mm 608 608 705 898 Height inches 47 55'/z 68% 77 mm 1189 1409 1746 1955 Tilt height inches 50 57'/z 70%2 73'/4 mm 1 260 1 460 1792 1860 Weight Ibs 190 214 333 399 Tank with insulation kg 86 97 151 181 Heating water content USG 1.45 1.45 2.6 3.3 Itr 5.5 5.5 10 12.5 Heat exchanger surface area ft.2 10.8 10.8 16.1 20.5 m2 1 1 1.5 1.9 Connections Heating water supply/return 0" (male thread) 1 1 1 1 Domestic cold/hot water 0" (male thread) % % 1 1'/4 T&P valve 0" (female thread) % % % % Recirculation 0" (male thread) % % 1 1 1 When planning for the recovery rate as stated or calculated, allow for the corresponding circulation pump. The stated recovery rate is o only achieved when the rated output of the boiler is equal to or greater than that stated under "Recovery rate". 00 Please also refer to the corresponding sizing chart at the end of this manual. - *2Measured values are based on a room temp. of 68°F/ 20 °C and a domestic hot water temp. of 149°F/ 65 °C and can vary by 5 %. r- 4 VIESMANN VITOCELL 100-V Technical Data 0 LO n m LO Vitocel 1001-V (42 and 53 USG / 160 and 200 Itr) Vitocell 100-V (79 USG / 300 Itr) co Vitocell 100-V (119 USG / 450 Itr) 0 25'/z" / 650 mm Dimensions Storage USG capacity Itr 42 160 53 200 79 300 119 450 a inches -- -- 13 16'/2 mm -- -- 336 422 b inches 2% 2% 3 4 mm 72 72 76 107 c inches 9% 9% 10 13% mm 249 249 260 349 d inches 25 25 34'/z 36'/4 mm 634 634 875 924 e inches 35 35 44 48'/2 mm 884 884 1115 1230 f inches 41 41 63 701/4 mm 1050 1270 1600 1784 g inches -- -- 26 33 mm -- -- 660 837 h inches 12'/2 12'/z 13'/2 18 mm 317 317 343 455 j 0 inches -- -- 4'/2 4'/2 mm -- -- 114 114 Legend 10 Inspection and clean -out opening D Drain BWR Boiler water return BWS Boiler water supply DCW Domestic cold water AQ Aquastat well (at same height as boiler water supply connection) MA Magnesium anode DHW Domestic hot water RT Recirculation tapping TPV Temperature and pressure relief valve VITOCELL 100-V VIESMANN 5 Technical Data Domestic hot water draw rate Storage tank contents heated to 140 of / 60 IC, boiler not reheating Storage capacity USG 42 53 79 119 Itr 160 200 300 450 DHW draw rate GPM 2.6 2.6 4.0 4.0 Itr/min 10 10 15 15 Domestic hot water draw USG 32 38 63 ill Water with t = 140 of / Itr 120 145 240 420 60 oC (constant) Percentage tank volume 1 75% 1 73% 80% 1 93% Heat -up time The stated heating times are achieved when the maximum recovery rate of the domestic hot water tank is made available at the respective supply temperature and with a domestic hot water rise from 50 to 140 of / 10 to 60 IC. Storage capacity USG 42 53 79 119 Itr 160 200 300 450 Heating water supply temperature Heat -up time (minutes) 194 of / 90 oC 19 19 23 28 176 of / 80 oC 24 24 31 36 158 of / 70 oC 1 34 37 45 50 Pressure drop on heating water side (primary circuit) Pressure drop on domestic hot water side (secondary circuit) U 200 160 120 80 40 32 24 20 16 12 8 4 C 3.2 2 2.4 m 2 a) L 1.6 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 00 Lo 0 00 0 0 0 0 0 0 0 N M �t Lo (o n Itr/h N (D Lq 't W M 00 N 0 N N M� N N M GPM Flow rate 6 VIESMANN U E 40 1 32 24 20 16 Z 8 4 3.2 2.4 2 1.6 iwl 8 10 13 17 33 50 67 83 100 Itr/min 2.2 2.6 3.5 4.4 8.8 13 18 22 26 GPM Flow rate _ OA 42 USG / 160 Itr and 53 USG / 200 Itr storage capacities Ln © 79 USG / 300 Itr storage capacity r- © 1 19 USG / 450 Itr storage capacity (° Y) VITOCELL 100-V Multiple Tank Installation (79 and 119 USG / 300 and 450 Itr only) Technical Data The 79 and 119 USG / 300 and 450 Itr tank sizes may be combined into a battery consisting of between 2 and 4 tanks. Tank batteries consisting of more than 4 tanks can be installed by creating up to 4 batteries, each consisting of 4 tanks. The heating contractor is responsible to ensure proper piping on both the primary and secondary circuits. Tank storage capacity USG 79 119 Itr 300 450 Total capacity of tank battery USG 159 238 357 476 Itr 600 900 1350 1800 Number of storage tanks 2 2 3 4 •• •• 909 9090 Recovery rate* t MBH 361 477 716 955 with a temperature rise 194 90 of oC GPM 11.5 15.1 22.7 30.3 of the domestic hot Itr/h 2604 3440 5160 6880 water from MBH 300 396 593 791 50 to 113 OF 176 OF GPM 9.5 12.5 18.8 25.1 10 to 45 °C 80 °C Itr/h 2162 2850 4275 5700 and boiler water supply temperature of ..... 158 OF MBH 225 307 460 614 at the supply flow rate 70 oC GPM 7.1 9.7 14.6 19.5 stated below Itr/h 1 622 2212 3318 4424 140 OF MBH 157 218 327 436 60 °C GPM 5 6.9 10.4 13.8 Itr/h 1 130 1 572 2 358 3144 122 OF MBH 123 164 246 327 50 o C GPM 3.9 5.2 7.8 10.4 Itr/h 884 1178 1767 2356 Recovery rate* MBH 307 361 542 723 with a temperature rise 194 OF GPM 6.8 8.0 12.0 16.0 of the domestic hot 90 o C Itr/h 1 548 1 822 2733 3644 water from MBH 232 300 450 600 50 to 140 OF / 176 OF GPM 5.1 6.7 10.0 13.3 0 10 to 60 C 80 0Itr/h 1 168 1 512 2268 3024 and boiler water supply temperature of ..... 158 OF MBH 157 225 338 450 at the supply flow rate 70 °C GPM 3.5 5.0 7.5 10.0 stated below Itr/h 790 1 134 1 701 2268 Supply flow rate GPM 26.4 26.4 39.6 50.8 for the recovery rates m3/h 6 6 9 12 stated Standby losses *2 MBH/24 h 15 19.2 28.8 38.4 Overall dimensions with insulation Overall width inches 57Yz 72Yz 111'/4 150 mm 1 461 1838 2826 3814 Overall depth inches 43'/2 48 48 48% mm 1109 1218 1218 1237 Overall height inches 69 77 77 77 mm 1 752 1955 1955 1955 Weight Ibs 736'/4 932 1409 1913 Tank with insulation kg 334 423 639 868 Heating water content USG 6'/2 8'/2 13 % 20 % (heat exchanger pipe coil) Itr 25 32 50 79 Heat exchanger surface area ft.2 32'/4 42 62'/2 84 m2 3.0 3.9 5.8 7.8 "When planning for the recovery rate as stated or calculated, allow for the corresponding circulation pump. The stated recovery rate is only achieved when the rated output of the boiler is equal to or greater than that stated under "Recovery rate". Please also refer to the corresponding sizing chart at the end of this manual. *2Measured values are based on a room temperature of 68°F/ 20 °C and a domestic hot water temperature of 149 °F/ 65 °C and can p vary by 5%. cc n m LO VITOCELL 100-V VIESMANN Multiple Tank Installation (79 and 119 USG / 300 and 450 Itr only) For domestic hot water applications which utilize modulating and low temperature hot water heating boilers or remote heating plants N7 Side view Legend 10 Inspection and clean -out opening D Drain A Air vent Dimensions Qty 2 l BWR C \ // 72 A 1 BWS \ / L Depth Top view BWR Boiler water return BWS Boiler water supply DCW Domestic cold water Qty 3 Qty 4 ]tit69 DHW Domestic hot water RT Recirculation tapping TPV T&P valve Storage capacity USG Itr 79 300 119 450 Total capacity of battery USG 159 238 357 476 Itr 600 900 1350 1800 Number of storage tanks 2 2 3 4 a inches 3 41/4 41/4 4'/4 mm 76 107 107 107 b inches 10'/4 13% 13% 13% mm 260 349 349 349 c inches 34'/2 36'/4 36'/4 36'/4 mm 875 924 924 924 d inches 63 70'/4 70'/4 70'/4 mm 1 600 1784 1784 1 784 e inches 16'/2 18 18 18 mm 343 455 455 455 h inches 8 12'/z 12'/2 12'/2 mm 12061 3151 3151 315 W u 8 VIESMANN VITOCELL 100-V Multilple Tank Installation (79 and 119 USG / 300 and 450 Itr only) 0 Lo n m Lo Domestic hot water draw rate Storage tank content heated to 140 of / 60 oC Storage capacity USG 79 119 Itr 300 450 Battery storage capacity USG 159 238 357 476 Itr 600 900 1350 1800 Number of tanks 2 2 3 4 DHW draw rate GPM 7.9 7.9 7.9 11.9 Itr/min 30 30 30 45 Domestic hot water draw USG 127 222 333 444 Water with t = 140 of / Itr 480 840 1 260 1 680 60 oC (constant) Percentage of battery volume 80% 84% 84% 1 84% Quick recovery lover 10-minute period) Domestic hot water rise from 50 to 113 of / 10 to 45 oC Storage capacity USG 79 119 Itr 300 450 Battery storage capacity USG 159 238 357 476 Itr 600 900 1350 1800 Number of tanks 2 2 3 4 Heating water supply temperature Quick DHW recovery (over 10-minute period) 194 of / 90 oC USG/10 min 201 317 441 540 Itr/10 min 759 1200 1 670 2045 176 of / 80 oC USG/10 min 197 310 431 502 Itr/10 min 745 1 175 1 630 1900 158 of / 70 oC USG/10 min 192 284 396 478 Itr/10 min 728 1 075 1 498 1 810 Max. domestic hot water draw rate lover 10-minute period) Domestic hot water rise from 50 to 113 of / 10 to 45 oC Storage capacity USG 79 119 Itr 300 450 Battery storage capacity USG 159 238 357 476 Itr 600 900 1350 1800 Number of tanks 2 2 3 4 Heating water supply temperature Max. DHW draw rate (over 10-minute period) 194 of / 90 oC GPM 20.1 32 44.1 54 Itr/min 76 120 167 204 176 of / 80 oC GPM 20 31.3 43.2 50.4 Itr/min 74 118 163 190 158 of / 70 oC GPM 19.3 28.4 40 48 Itr/min 73 107 150 181 VITOCELL 100-V VIESMANN 9 Standard Equipment Product Installation Standard Equipment Vitocell 100-V 42 to 79 USG / 160 to 300 Itr capacity Domestic hot water storage tank of high-grade steel with PUR Foam insulation (HCFC-free) and Ceraprotect two -coat enamel finish with: ■ thermometer ■ adjustable leveling feet ■ built-in aquastat well ■ Magnesium anode The following is packed separately and attached to the crate: ■ installation fittings package: with the necessary brass adaptors, other necessary hardware, and hemp ■ temperature and pressure relief valve. Electrostatically powder -coated sheet metal enclosure panel in a Vitosilver finish. Domestic hot water connections 0 I I Y I 0 I I I I I II 0 L Vitocell 100-V 119 USG / 450 Itr capacity Domestic hot water storage tank of high-grade steel with wrap -around soft PET insulation (HCFC-free) and Ceraprotect two -coat enamel finish with: ■ thermometer ■ adjustable leveling feet ■ built-in aquastat well ■ Magnesium anode The following is packed separately and attached to the crate: ■ installation fittings package: with the necessary brass adaptors, other necessary hardware, and hemp ■ temperature and pressure relief valve. Synthetic wrap -around enclosure panel in a Vitosilver finish. O IMPORTANT This is a simplified conceptual drawing only! Piping and necessary componentry must be field verified. Proper installation and functionality in the field is the responsibility of the heating contractor. OA Domestic hot water supply © DHW recirculation line © DHW recirculation pump OD Spring -loaded flow check valve OE Discharge pipe OF Temperature and pressure relief valve (TPV) OG Shut-off valve OH Drain OK Domestic cold water supply lines © Backflow preventer MO Domestic cold water inlet NO Precharged expansion tank (required where backflow preventer is installed; check local plumbing codes and requirements) 0 Thermostatic mixing valve/anti-scald valve for solar applications (field supplied) W u 10 VIESMANN VITOCELL 100-V Product Installation 0 co n LO Backflow preventers Where backflow preventers are required, a domestic water expansion tank installation is recommended in the cold water inlet piping before the cold water enters the Vitocell. For the backflow device, observe local plumbing codes and regulations. Temperature and pressure relief valve A temperature and pressure relief valve (T&P relief valve) is supplied with the tank. The heating contractor must install the valve on each tank in a method meeting code requirements. If local codes require a different relief valve, substitute the manufacturer's supplied valve. The tank is approved for 150 psig. Maximum operating pressure is 150 psig. The T&P relief valve supplied with the tank is tested under ANSI Z21 .22 Code for Relief Valves and Automatic Gas Shut-off Devices for Hot Water Supply Systems. IMPORTANT Since the heat exchanger coil allows for high MBH input (see Vitocell flow charts), confirmation that the appropriate and correct size pressure and temperature relief valve is used and installed, is necessary. Watts Model 150 psig 40XL-8 (US and Canada) ASME pressure 1438 MBH steam rating CSA temperature 205 MBH steam rating Relief 210°F (99°C) temperature Inlet thread 3/4" male Outlet thread 3/4" female Warranty Our warranty for domestic hot water tanks states that the water heated must be of drinking (potable) water quality and that any water treatment equipment in use must function correctly. Viessmann accepts no responsibility for damage howsoever caused and reserves the right to withdraw the product warranty if the product has been improperly installed or misapplied by the installer, contractor or final user. In order to qualify for product warranty, strict adherence to the installation and service manuals must be assured. In the event that Viessmann non -approved components are utilized, Viessmann reserves the right to withdraw all expressed or implied warranties without written notice. The water to be heated with the Vitocell must be drinking (potable) water quality. If the tank is used to heat other media, the warranty will be null and void. Damage resulting from excessive pressure or temperature is clearly not the responsibility of Viessmann. The amount of chloride and sulfate acceptable to the tank is limited. In areas where high concentrations of chloride and sulfate are present in drinking water, please consult Viessmann for directions. Sensor Well Vitocell 100-V 42 to 119 USG / 160 to 450 Itr capacity The sensor well is welded into the domestic hot water storage tank. M E cY) 0 /2 N 14.9 mm 8" / 200 mm VITOCELL 100-V VIESMANN 11 Vitocell 100-V Sizing Continuous Flow Capacity Chart Vitocell 100-V, 42 and 53 USG / 160 and 200 Itr capacities Curve 0 Domestic hot water 40 to 113°F / 4 to 45°C Curve Domestic hot water 40 to 140°F / 4 to 60°C :3 Btu/h kW a — 0 204,000 60 L N 187,000 55 O M 170,000 50 0 0 L 153,000 45 N C C- 136,000 40 U X N 119,000 35 O N 102,000 30 C O Mom 25 N Q� a 0 68,000 20 0 V) O 41 51,000 15 c- 34,000 10 c 17,000 5 a Q) = 0 a� o 3 N CQ 3� Jy o ^� Q N' , r \• � h o N ^: 90'C/194'F 90'C/194'F 80'C/176T ♦♦♦ �00 O o Q ♦ CV. L ♦ ♦♦ A O 80'C/176'F 70'C/158'F ♦♦ B 70'C/ 158' F O -60'C/140'F 1 B O441l-T-T- Domestic hot water delivery rate 4'C-45'C 4'C-60'C 40'F-113'F 40'F-140'F Ltr/h Ltr h USGH USGH 1262 921 333 243 1052 768 278 203 841 614 222 162 631 461 167 122 420 307 111 81 211 154 56 41 0 5 10 15 20 25 30 35 40 ° C 9 18 27 36 45 54 63 72 OF Temperature difference (Boiler supply — Boiler return) co r, LO 12 VIESMANN VITOCELL 100-V 0 L0 r, CD L0 Vitocell 100-V, 79 USG / 300 Itr capacity Curve 0 Domestic hot water 40 to 1131F / 4 to 45°C Curve Domestic hot water 40 to 140°F / 4 to 60°C Btu/h kW 221,000 75 238,000 70 i--. 221,000 65 7 a 0 204,000 60 L N 187,000 55 O m �o 170,000 50 U L 153,000 45 N C 136,000 40 U X N _ 119,000 35 O N 102,000 30 c v 85,000 25 N f v 0 68,000 20 41 O 41 51.000 15 41 a 34,000 10 c rn C 17.000 s v a� = 0 Vitocell 100-V Sizing Continuous Flow Capacity Chart a ; ..? Qg `o CVJ� r N ti ^'i cc0 r h 0 4 h 90'C/194'F 90'C/194'F ♦ a. 80'C/176T ♦ Jgoe ' o ♦ ♦ a r ♦ oo Qo —80'C/176'F �0 6� -70'C/158'Fk ♦♦♦ Ary ♦ O 6 70'C/ 158' F ♦ 0 50'C/140'F ♦ A Domestic hot water delivery rate 4'C-45'C 4'C-60'C 40'F-113'F 40'F-140'F Ltr/h Ltr/h USGH USGH 1724 1075 455 284 1262 921 333 243 1052 768 278 203 841 614 222 162 631 461 167 122 420 307 111 81 211 154 56 41 0 5 10 15 20 25 30 35 40 45 o C 9 18 27 36 45 54 63 72 81 OF Temperature difference (Boiler supply — Boiler return) VITOCELL 100-V VIESMANN 13 Vitocell 100-V Sizing Continuous Flow Capacity Chart Vitocell 100-V, 119 USG / 450 Itr capacity Curve 0 Domestic hot water 40 to 113°F / 4 to 45°C Curve Domestic hot water 40 to 140°F / 4 to 60°C Btu/h kW 306,000 90 289.D00 85 272,000 80 255,000 75 238,000 70 221,000 65 3 a 0 204,000 60 L 0) 187,D00 55 O m 170,000 50 �o U 153,000 45 0) 01 C s 136,000 40 U X 0) 119,0D0 35 0 N -C 102,000 30 c a 85,DDo 25 0 01 a 0 68,000 20 U) 0 51.000 15 a 34,000 10 a C 17,000 5 0 0) = 0 OMENMEN MEMEMENEE e FAIWIDNEEMENwiloommum RNMEEMN EUVEREEME MMM ME MEMO ME mmmm MEE 911A M 0 ME FIIA MMM riMMMMMM Domestic hot water delivery rate 4T-45C 4'C-60'C 40'F-113'F 40'F-140'F Ltr/h Ltr/h USGH USGH 1893 1382 500 365 1682 1228 444 324 1473 1075 389 284 1262 921 333 243 1052 768 278 203 841 614 222 162 631 461 167 122 420 307 1-1 81 211 56 0 5 10 15 20 25 30 35 40 45 ° C 9 18 27 36 45 54 63 72 81 o F Temperature difference (Boiler supply — Boiler return) 154 41 a2 LO r` LO 14 VIESMANN VITOCELL 100-V Vitocell 100-V Sizing Continuous Flow Capacity Chart Example: Vitocell 100-V, 119 USG / 450 Itr capacity Assume boiler output to tank is 170 MBH. Enter chart at left and draw horizontal line across to recovery rate of 203 GPH / 3.4 GPM for 140°F / 60oC domestic hot water under column B. Where the horizontal line intersects the 194oF / 90°C curve is the point of intersection for the diagonal line used to size the pump. The diagonal line begins at the origin and goes through the point of intersection extending up to the top of the chart. Read between the reference diagonal lines to get a pump specification of 11 .9 GPM at 5 ft. To summarize: For a Vitocell-V 100 with 119 USG / 450 Itr capacity and 170 MBH input, the boiler water temperature is 1940F / 900C, difference between boiler return and supply water temperature is 31 OF / 170C, recovery rate is 3.4 GPM of 1400F / 600C DHW, and the pump required is 11.9 GPM, 5.0 ft. plus pressure drop in piping and boiler. Btu/h kW 306,000 90 2a%000 a5 272,000 80 255,000 75 238,000 70 221.000 65 a D 0 204,000 60 m 0 m Output from 187.000 55 — boiler o Input to tank 170,000 50 a 170,000 Btu/h v v1 153,000 45 c v X 136,000 40 W 0 119.000 35 0 L C 102,000 3 0 0 0 85,000 25 01 0 N 68,000 20 0 51.000 15 CL S 34,000 10 v1 c 17.000 5 v 0 2 0 Domestic hot water delivery rate 0 4'C-45C 4'C-60'C a 40T-113'F 40'F-140'F U W Ltr/h Ltr/h 3 USGH USGH N U 1R93 138? MEN 0 mom 1682 1228 �454— 324 0 mom No NO rJAMEN 1473 1075 EEF§E J284 ICI 203 NoT7-8— 6 MA 0 Hi 10 11 E 0 0 P, M 841 614 222 162 N 04, 0. 1110� WIAAAIIIIILVIFANEE� 631 461 157 122 IV%Jj'h1j WOUNNE 55 F-S" 91, r/A 0 0 0 0 0 420 307 0711 r NONE ' 111 :0111100011 VII/ FAF:0111100011 _ 0 5 10 15 20 25 30 35 40 45 ^ C O 9 18 27 36 45 54 53 72 51 , F of L0 31 'F n Difference between CD boiler supply and return 203 GPH 3.4 GPM 140 T DHW LO Temperature difference (Boiler supply — Boiler return VITOCELL 100-V VIESMANN 15 92(3) C C �a cc E U C ? O U N C -O N C C � 0-0 O U + ? C U i N d WOO Viessmann Manufacturing Company Inc. Viessmann Manufacturing Company (U.S.) Inc. 750 McMurray Road 45 Access Road o Waterloo, Ontario • N2V 2G5 • Canada Warwick, Rhode Island • 02886 • USA Techlnfo Line 1-888-484-8643 Techlnfo Line 1-888-484-8643 LO 1-800-387-7373 9 Fax (519) 885-0887 1-800-288-0667 • Fax (401) 732-0590 www.viessmann.ca .info@viessmann.ca www.viessmann-us.com . info@viessmann-us.com LO 16 VIESMANN VITOCELL 100-V Technical Data Manual Model Nos. and pricing: see Price List For Natural Gas and Liquid Propane Gas Gas -fired wall -mounted condensing boiler 12 to 199 MBH (3.5 to 58 M Multi -boiler installation 32 to 1592 MBH VITODENSo 200-W Product may not be exactly as shown Vitodens 200-W, Series B21HIB Gas -Fired Wall -Mounted Condensing Boiler with modulating MatriX cylinder burner for room air independent operation (using a direct vent system) or room air dependent operation. VI ESMAN N S Energy Verified Fi A I 5461 883 - 14 09/2018 Product Information Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data Vitodens 200-W Equipped with the industry's first intelligent combustion management system and powerful control technology, the new generation Vitodens 200-W gas -fired wall -mount condensing boiler delivers unparalleled performance, reliability and comfort. The benefits at a glance: ■ Best value in its class with new industry -leading technology and the most standard features. ■ Highest Efficiency up to 98% at full modulation and up to 95% A.F.U.E. ■ Lasting performance with industry -leading Viessmann made SA240 / S43932 stainless steel Inox-Radial heat exchanger constructed to CSA B51 and ASME Section IV. ■ Low Emission Combustion with Viessmann made stainless steel MatriX cylinder burner. Factory calibrated. ■ Fast Installation and Reduced Maintenance with Lambda Pro, industry -first intelligent combustion management system: Adjusts automatically to gas type and quality. No fuel conversion kit required. ■ Powerful and User-friendly Viessmann Vitotronic on -board multi -function outdoor reset boiler and system control for multi -temperature space and DHW heating. ■ Greater Venting Flexibility with increased vent length up to 180 ft. (55 m) and multiple venting options. Horizontal or vertical sealed combustion coaxial venting (field supplied). Horizontal, vertical or hybrid sealed combustion double -pipe venting (field supplied). Horizontal or vertical single -wall venting (field supplied). ■ Compact, Esthetic Product Design and zero clearance to combustibles. ■ Extremely Quiet Operation; quieter than most refrigerators. ■ True High -Altitude Operation up to 10,000 ft. (3,000 m) with simple electronic adjustment. ■ Efficiency up to 98% through intensive condensation. The flue gas temperature is only approximately 9-27°F (5-15°C) above boiler return temperature (see chart below). co 00 00 LO Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data Cross -Section Vitodens 200-W B2HB 19, 26, 35, 45, 57 Product may not be exactly as shown The flue gas temperature is only approximately 9-27°F (5-15°C) above boiler return temperature (see chart below). 100 99 96 SUPOV Rerum 97 4O-C 10+1"F 301C f 80 "F 9S l:uv 0. 96 94 93 Deei0n 92 Supply ! Rerbm. 91 75'r 1 60"C 167°F11f0'F 9D Curva 1 .4 Qee�ll 89 p as -.rw + r>nt�rrWrY` M u 9O.rSr71Y C ! t9a°F1156"F W ae 1.a d es 84 - 0 30 e0 so ae 70 84 90 104 System Partial Load in % Vitodens 200-W 4oilbr bffi rignpy dependant 4n Sy8t0m heating water return temperatures and load conditions M 00 W LO lS) Product Information (2 Inox-Radial heat exchanger made from stainless steel — for high operational reliability and a long service life. Large heating output in the smallest of spaces © Modulating MatriX cylinder burner for extremely clean combustion and quiet operation © Variable speed combustion fan for quiet and economical operation Gas and water connections Digital boiler control unit Delivered condition Wall mounted gas condensing boiler with Inox-Radial heat exchanger, modulating MatriX cylinder burner for natural gas and LPG, plus wall mounting bracket. Vitotronic 200 for weather -compensated operation. Preset for operation with natural gas. Fully plumbed and wired. White epoxy - coated casing. "F IC 5 330 11C F E212 1C)i a 794 9[ n ti 176 6C 'm 158 7C `m 0 m 140 6C 122 6C 104 4( ro 216 2.6 2.2 2,0 1.8 1.8 1.4 1.� 1.0 ().6 as 0. 0.2 )1C 41 32 23 14 5 -4 "F Outdoor TemperalUr¢ ,t7 Technical Data Technical Data Vitodens 200-W, 132HB 19 to 57, 68 to 199 Technical Data Boiler Model No. 200-W B2HB 19,68 26,94 35, 125 45, 160 57, 199 CSA input Natural Gas (NG) MBH 12-68 19-94 19-125 32-160 32-199 (kW) (3.5-20) (5.5-27) (5.5-37) (9-47) (9-58) CSA input Liquid Propane Gas (LPG) MBH 12-68 31-94 31-125 60-160 60-199 (kW) (3.5-20) (9-27) (9-37) (17.5-47) (17.5-58) CSA output/DOE *1 MBH 11-64 18-88 18-117 30-149 30-185 heating capacity NG (kW) (3.2-19) (5-26) (5-34) (9-44) (9-54) CSA output/DOE *1 MBH 11-64 29.5-88 29.5-117 56-149 56-185 heating capacity LPG (kW) (3.2-19) (8.6-26) (8.6-34) (17-44) (17-54) Net AHRI rating *2 MBH 55 77 102 127 160 (kW) (16) (22) (30) (37) (47) Heat exchanger surface area ft.2 12.96 12.96 12.96 31.99 31.99 (m2) (1.2) (1.2) (1.2) (2.9) (2.9) Min. gas supply pressure Natural gas "w.c. 4 4 4 4 4 Liquid propane gas "w.c. 10 10 10 10 10 Max. gas supply pressure *3 Natural gas "w.c. 14 14 14 14 14 Liquid propane gas "w.c. 14 14 14 14 14 A.F.U.E. % 95.0 95.0 95.0 95.0 95.0 Weight Ibs 110 110 110 210 210 (kg) (50) (50) (50) (95) (95) Boiler water content USG 1.02 1.02 1.02 3.85 3.85 (L) (3.88) (3.88) (3.88) (14.6) (14.6) Boiler max. flow rate *4 GPM 6.2 6.2 6.2 14.3 14.3 (L/h) (1400) (1400) (1400) (3250) (3250) Max. operating pressure psig 45 45 45 60 60 at 2107 (99°C) (bar) (3) (3) (3) (4) (4) Boiler water temperature Adjustable high limit (AHL) range space heating (steady state) OF 68 to 165 68 to 180 68 to 180 68 to 180 68 to 180 (°C) (20 to 74) (20 to 82) (20 to 82) (20 to 82) (20 to 82) DHW production OF 165 180 180 180 180 (°C) (74) (82) (82)210 (82) (82) Fixed high limit (FHL) OF (°C) 210 (99) 210 (99) (99) 210 (99) 210 (99) Boiler connections Boiler heating supply and return NPTM" % % % 11/2 V/2 Pressure relief valve NPTF" % % % % % Drain valve (male % % % % % thread) Boiler supply/return for indirect -fired DHW storage tank NPT" 3/a 3/a 3/a 11/2 V/2 (field supplied) Gas valve connection NPTF" % % % 1 1 * 1 Output based on 140OF (60°C), 120°F (49°C) system supply/return temperature. *2 Net AHRI rating based on piping and pick-up allowance of 1 .15. *3 If the gas supply pressure exceeds the maximum gas supply pressure value, a separate gas pressure regulator must be installed upstream of the heating system. *4 See "Waterside Flow" starting on page 9 in this manual. Co 00 00 LO Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data Technical Data Technical Data Boiler Model No. 200-W B2HB 19,68 26,94 35, 125 45, 160 57, 199 Dimensions Overall depth in. (mm) 15.7 (400) 15.7 (400) 15.7 (400) 21 (530) 21 (530) Overall width in. (mm) 17 % (450) 17 % (450) 17 % (450) 19 (480) 19 (480) Overall height in. (mm) 41 (1040) 41 (1040) 41 (1040) 431/2 (1105) 431/2 (1 105) Flue gas *5 Temperature (at boiler return temperature of 86°F (30°C) at rated full load OF (°C► 113 (45) 113 (45) 113 (45) 95 (35) 104 (40) at rated partial load OF (°C► 95 (35) 95 (35) 95 (35) 91 (33) 95 (35) Temperature (at boiler return OF (°C► 154 (68) 154 (68) 154 (68) 149 (65) 158 (70) temperature of 140OF (60°C) Flue gas parameters Mass flow rate Natural gas at rated heating output Ib/h (kg/h) 70.1 (31.8) 96.8 (43.9) 129.4 (58.7) 172 (78) 229 (104) (DHW heating) at partial load Ib/h (kg/h) 12.1 (5.5) 19.2 (8.7) 19.2 (8.7) 66 (30) 66 (30) Liquid propane gas at rated heating output Ib/h (kg/h) 66.6 (30.2) 91.9 (41.7) 122.8 (55.7) 163 (74) 218 (99) (DHW heating) at partial load Ib/h (kg/h) 16.8 (7.6) 30.9 (14.0) 30.9 (14.0) 62 (28) 62 (28) Max. condensate flow rate *6 with natural gas and TS/TR=122/86°F (50/30°C) USG/h (L/h) 0.66 (2.5) 0.97 (3.7) 1.21 (4.6) 1.55 (6.0) 2.0 (8.0) Condensate connection * 7 hose nozzle 0 in 3/4-1 3/4-1 3/4-1 3/4-1 3/4-1 Boiler flue gas connection *8 0 in (mm) 23/8 (60) 23/8 (60) 23/8 (60) 3'/4 (80) 3'/4 (80) Combustion air supply outer connection (coaxial) 0 in (mm) 4 (100) 4 (100) 4 (100) 5 (125) 5 (125) Sound Rating at maximum input dB 41 48 51 56 67 at minimum input dB 35 36 36 39 39 NOx @ 3% 02 <20 PPM *9 *5 Measured flue gas temperature with a combustion air temperature of 68°F (201C). *6 Based on maximum input rate. *7 Requires 1 inch (25 mm) tubing. See the Installation Instructions of the Vitodens 200-W, B21HIB for details. *8 For side wall vent installations (coaxial system): Do not exceed max. equivalent length specified in the Installation Instructions of the Vitodens 200-W, B2HB Venting System. Do not attempt to common -vent Vitodens 200-W B21HIB 19-35, 68-125 with any other appliance. The Vitodens 200-W B2HB 45, 57, 160, 199 can only be common vented with other Vitodens 200-W boilers of the same size and series. Side wall co -axial vent installation must include Viessmann protective screen! For details refer to the Installation Instructions for the Vitodens 200-W, B21HIB Venting System. For information regarding other Viessmann System Technology componentry, please reference documentation of respective product. *9 Optional low NOx certified by SCAQMD Natural Gas models available. Note: For high altitude installation at 10,000 ft. the input for model B2HB 19 to 199 will have an altitude de -ration of 21 %. co 00 00 Lo Dimensional Information Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data Models 200-W, 1321-113 19, 26, 35, 68, 94, 125 i17.8 in. (450 mm) — 4.8 in. 4.8 in. u (123 mm) 0 23 mm) Legend Boiler Supply © Gas Connection, %" NPTF © Boiler Return Recommended height (single boiler system) N c E LO M Co 0) M v [D n (150 mm) •2.8 in. (70 mm) n P11 hII I I L I 8 2 in. (50 mm) E 15.7 in. (400 mm) QE Condensate drain Combustion air intake (left or right) © Combustion air intake (through co -axial) 00 00 LO 6 Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data Dimensional Information Models 200-W, 1321-113 45, 57, 160, 199 19 in. (480 mm}`� E E N E B C N E — It o r� rn n ai N C N - N M 00 M I VV Illlllf k I VV Illlllf Legend Boiler Supply, 11/2" © Gas Connection, 1 " NPTF © Boiler Return, 11/2" Recommended height (single boiler system) Condensate drain CO 00 00 LO 6.1 in. Minimum Clearances Vitodens 200-W, 132HB 19 to 57, 68 to 199 Technical Data Recommended Minimum Service Clearances Q "Imm Side Ell 0"/mm Minimum Clearances to Combustibles Top Front Rear Left Right Vent pipe * 1 0 0 AL, CL 0 0 0 0 AL = Alcove CL = Closet * 1 Refer to the Installation Instructions of the Vitodens 200-W, B2HB Venting System for details. Note:The Vitodens boiler has passed the zero inches vent clearance to combustibles testing requirements dictated by the Harmonized Standard ANSI Z21.13. CSA 4.9 (latest edition) and therefore is listed for zero clearance to combustibles when vented with a single wall special venting system (AL-29-4C material). The zero inches vent clearance to combustibles for the Vitodens boiler supercedes the clearance to combustibles listing that appears on the special venting system label. CO 00 00 LO Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data Waterside Flow (primary circuit) The Vitodens 200-W, B2HB is designed for closed loop, forced circulation hot water heating systems only. Use standard friction loss method for pipe sizing. Observe boiler maximum and minimum flow rate limitations. If system flow rate exceeds boiler maximum flow rate (as stated above), falls below the minimum flow rate or if system flow rate is unknown, Viessmann strongly recommends the installation of a low -loss header. An alternative method may be used, such as primary secondary piping using closely spaced tees. 19.7} H(m) Co Co 16.4 a� 13.1 U) m Co Co m 6.6 T Q 3.3 1 s 5 4 3 2� 500 1000 1500 L/h 2.2 4.4 6.6 GPM Flow rate H(ft.) H(m) 10.0 3.1 m 2 n- 6.7 2.0 n n En 3.4 1.0 Waterside Flow A low -loss header offers additional benefits not provided by a pair of closely spaced tees. Viessmann therefore strongly recommends and prefers the use of a low -loss header over closely spaced tees. See pages 30 and 31 for low -loss header information. Once the low -loss header is connected, the built-in low -loss header logic of the Vitodens 200-W boiler ensures the required At across the system through the sensory communication between the low -loss header and the boiler. Pressure drop (primary circuit) for Vitodens 200-W, B2HB 19, 26, 35, 68, 94, 125 For sizing an on -site circulation system. Max. flow rate: 6.2 GPM (1400 L/h) Pressure drop (primary circuit) for Vitodens 200-W, B2HB 45, 57, 160, 199 For sizing an on -site circulation system. Max. flow rate: 14.3 GPM (3250 L/H) LM 500 1000 1500 2000 2500 3000 3500 USG/m 2.2 4.4 6.6 8.8 11 13.2 15.4 Flow Rate C0 00 00 LO 9 500 1000 1500 L/h 2.2 4.4 6.6 GPM Flow rate H(ft.) H(m) 10.0 3.1 m 2 n- 6.7 2.0 n n En 3.4 1.0 Waterside Flow A low -loss header offers additional benefits not provided by a pair of closely spaced tees. Viessmann therefore strongly recommends and prefers the use of a low -loss header over closely spaced tees. See pages 30 and 31 for low -loss header information. Once the low -loss header is connected, the built-in low -loss header logic of the Vitodens 200-W boiler ensures the required At across the system through the sensory communication between the low -loss header and the boiler. Pressure drop (primary circuit) for Vitodens 200-W, B2HB 19, 26, 35, 68, 94, 125 For sizing an on -site circulation system. Max. flow rate: 6.2 GPM (1400 L/h) Pressure drop (primary circuit) for Vitodens 200-W, B2HB 45, 57, 160, 199 For sizing an on -site circulation system. Max. flow rate: 14.3 GPM (3250 L/H) LM 500 1000 1500 2000 2500 3000 3500 USG/m 2.2 4.4 6.6 8.8 11 13.2 15.4 Flow Rate C0 00 00 LO 9 System Flow Rates Typical System Flow Rates Boiler maximum flow rate 6.2 GPM (1400 L/h) Model 132HB 19, 68 1 boiler Output (NG/LPG) MBH 64 4t for NG/LPG 20°F (11°C) rise GPM (L/h) 6.4(1453) 25°F (14°C) rise GPM (L/h) 5.1 (1163) 30°F (17°C) rise GPM (L/h) 4.3(969) 357 (19.50C) rise GPM (L/h) 3.7(830) 40°F (22°C) rise GPM (L/h) 3.2(727) Boiler maximum flow rate 6.2 GPM (1400 L/h) Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data Boiler maximum flow rate 14.3 GPM (3250 L/h) Model 132HB 45, 160 1 boiler Output (NG/LPG) MBH 149 Ot for NG/LPG 20°F 01°C) rise GPM (L/h) 14.9 (3384) 25°F (14°C) rise GPM (L/h) 11.9 (2707) 30°F 0 7°C) rise GPM (L/h) 9.9(2256) 35°F (19.51C) rise GPM (L/h) 8.5(1934) 40°F (22°C) rise GPM (L/h) 7.50692) Boiler maximum flow rate 14.3 GPM (3250 L/h) Model 132HB 26, 94 1 boiler Model 132HB 57, 199 1 boiler Output (NG/LPG) MBH 88 Output (NG/LPG) MBH 185 Ot for NG/LPG Lt for NG/LPG 20°F (11 °C) rise GPM (L/h) 8.80999) 20OF (11IQ rise GPM (L/h) 18.5 (4201) 14.8 (3361) 250F (14°C) rise GPM (L/h) 7.0 (1599) 250F (14°C) rise GPM (L/h) 12.3 (2801) 30OF (17°C) rise GPM (L/h) 5.90332) 30°F (170C) rise GPM (L/h) 10.6 (2401) 350F (19.50C) rise GPM (L/h) 5.00142) 35°F (19.50C) rise GPM (L/h) 9.3(2101) 40OF (22°C) rise GPM (L/h) 4.4(999) 40°F (22°C) rise GPM (L/h) Boiler maximum flow rate 6.2 GPM (1400 L/h) Model 132HB 35, 125 1 boiler Output (NG/LPG) MBH 117 Ot for NG/LPG 20°F 01IQ rise GPM (L/h) 11.7 (2657) 25°F 04°C) rise GPM (L/h) 9.4(2126) 30°F (171C) rise GPM (L/h) 7.8(1771) 350F 09.50C) rise GPM (L/h) 6.7(1518) 40°F (22°C) rise GPM (L/h) 5.9(1328) Heating Circuit / Boiler Pumps � Viessmann offers a variety of Grundfos heating circuit/ Before using the following pumps for a DHW tank boiler pumps which meet typical Vitodens system application, find out the proper pressure drop through the installation requirements (see "Heating circuit pump tank, the required temperature difference through the coil (field supplied)" or "Boiler pump (field supplied)" in the and system piping head loss of the domestic hot water. Installation Examples starting on page 33). See tables below for recommended pumps. Refer to the graph IMPORTANT on page 9 for the proper waterside boiler friction loss calculations. The following pumps have been selected Pump selection must be based on accurate system flow based on boiler heat exchanger head loss and boiler piping and pressure drop calculations (includes DHW sizing). to a low -loss header. Model 132HB 19, 68 B2HB 26, 94 132HB 35, 125 Flow rate 20OF Ot GPM (L/h) - -- -- 25°F Ot GPM (L/h) 5.1 (1163) -- -- 30°F Ot GPM (L/h) 4.3(969) 5.9 (1332) - 35°F Ot GPM (L/h) 3.7 (830) 5.00142) -- 40°F Ot GPM (L/h) 3.2 (727) 4.4(999) 5.9 (1328) Flow limitation GPM (L/h) 6.2(1400) 6.2(1400) 6.2(1400) Recommended boiler pumps Grundfos UPS 15-58 (3-speed), Taco 0015, Wilo Star S 21 FX ice It M co M LO Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data Pump Information Pump Selection Model B2HB 45, 160 Flow rate GPM (L/h) Boiler pressure drop ft. (m) Recommended pump option 1 Grundfos Recommended pump option 2 Grundfos 20° F At - - - - 25° F At 11.9 (2707) 15.4 (4.7) UPS 26-99FC, 1 15V, Speed2 UP 26-64F, 1 15V 300 F At 9.9 (2256) 10.4 (3.2) UPS 26-99FC, 1 15V, Speed2 - 35° F At 8.5 (1934) 8.0 (2.5) UPS 26-99FC, 115V, Speed1 - 40° F At 7.5 (1692) 6.3 (1.9) UPS 26-99FC, 115V, Speed1 - Flow limitation 14.3 GPM (3250 L/h) Model B2HB 57, 199 Flow rate GPM (L/h) Boiler pressure drop ft. (m) Recommended pump option 1 Grundfos Recommended pump option 2 Grundfos 200 F At 250 F At - -- -- -- 30° F At 12.3 (2801) 13.5 (4.1) UPS 26-99FC, 1 15V, Speed2 UP 26-64F, 1 15V 350 F At 10.6 (2401) 12.7 (3.9) UPS 26-99FC, 1 15V, Speed2 UP 26-64F, 1 15V 400 F At 9.3(2101) 9.0 (2.7) UPS 26-99FC, 115V, Speed1 -- Flow limitation 14.3 GPM (3250 L/h) Low -Loss Header Application Sizing of Low -Loss Header in a Residential Single -Boiler Application Boiler No. of Boiler Typical System Flow Rates Viessmann Model Boilers Max. Low -loss Flow Temp. Rate Sensor GPM Required (L/h) At *1 OF 20 25 30 35 40 (°C) (11.0) (14.0) (17.0) (19.5) (22.0) B2HB 1 6.2 System Flow GPM 6.4 5.1 4.3 3.7 3.2 Included 19, 68 (1400) Rate (L/h) (1453) (1163) (969) (830) (727) LLH Required Yes Optional Optional Optional Optional LLH Model 80/60 80/60 80/60 80/60 80/60 B2HB 1 6.2 System Flow GPM 8.8 7.0 5.9 5.0 4.4 Included 26, 94 (1400) Rate (L/h) (1999) (1599) (1332) (1142) (999) LLH Required Yes Yes Optional Optional Optional LLH Model 80/60 80/60 80/60 80/60 80/60 B2HB 1 6.2 System Flow GPM 11.7 9.4 7.8 6.7 5.9 Included 35, 125 (1400) Rate (L/h) (2657) (2126) (1771) (1518) (1328) LLH Required Yes Yes Yes Yes Optional LLH Model 80/60 80/60 80/60 80/60 80/60 * 1 For system At < 20°F use low -loss header sizes for At 20*F. M Co 00 it System Flow Rates Vitodens 200-W, 1321­16 19 to 57, 68 to 199 Technical Data Low -Loss Header Application (continued) Boiler No. of Boiler Total Typical System Flow Rates Viessmann Model Boilers Max. Flow Low -loss Flow Rate Temp. Rate Sensor Required 4t *1 OF 20 25 30 35 40 (°C) (11) (14) (17) (19.5) (22) B2HB 1 14.3 14.3 System Flow GPM 14.9 11.9 9.9 8.5 7.5 Included 45, (3250) (3250) Rate (L/h) (3384) (2707) (2256) (1934) (1692) 160 LLH Required Yes OPT OPT OPT OPT LLH Model 80/60 80/60 80/60 80/60 80/60 B2HB 2 14.3 28.6 System Flow GPM 29.8 23.8 19.9 17.0 14.9 Yes 45, (3250) (6500) Rate (L/h) (6768) (5414) (4512) (3867) (3384) 160 LLH Required Yes Yes Yes Yes Yes LLH Model 120/80 120/80 120/80 80/60 80/60 B2HB 3 14.3 42.9 System Flow GPM 44.7 35.8 29.8 25.5 22.4 Yes 45, (3250) (9750) Rate (L/h) (101 51) (8121) (6768) (5801) (5076) 160 LLH Required Yes Yes Yes Yes Yes LLH Model 200/120 160/80 120/80 120/80 120/80 B2HB 4 14.3 57.2 System Flow GPM 59.6 47.7 39.7 34.1 29.8 Yes 45, (3250) (13000) Rate (L/h) (13535) (10828) (9023) (7734) (6768) 160 LLH Required Yes Yes Yes Yes Yes LLH Model 200/120 200/120 160/80 120/80 120/80 B2HB 5 14.3 71.5 System Flow GPM 74.5 59.6 49.7 42.6 37.3 Yes 45, (3250) (16250) Rate (L/h) (16919) (13535) (11279) (9668) (8459) 160 LLH Required Yes Yes Yes Yes Yes LLH Model 200/120 200/120 200/120 160/80 160/80 B2HB 6 14.3 85.8 System Flow GPM 89.4 71.5 59.6 51.1 44.7 Yes 45, (3250) (19500) Rate (L/h) (20303) (16242) (13535) (11602) (10151) 160 LLH Required Yes Yes Yes Yes Yes LLH Model 250/150 200/120 200/120 200/120 200/120 B2HB 7 14.3 100.1 System Flow GPM 104.3 83.4 69.5 59.6 52.2 Yes 45, (3250) (22750) Rate (L/h) (23687) (18949) (15791) (13535) (11843) 160 LLH Required Yes Yes Yes Yes Yes LLH Model 250/150 250/150 200/120 200/120 200/120 B2HB 8 14.3 114.4 System Flow GPM 119.2 95.4 79.5 68.1 59.6 Yes 45, (3250) (26000) Rate (L/h) (27070) (21656) (18047) (15469) (13535) 160 LLH Required Yes Yes Yes Yes Yes LLH Model 250/150 250/150 200/120 200/120 200/120 * 1 For system At < 20' F use low -loss header sizes for Ot 201 F. M CO 00 G LO 12 Vitodens 200-W, 1321­113 19 to 57, 68 to 199 Technical Data System Flow Rates Low -Loss Header Application (continued) Boiler No. of Boiler Total Typical System Flow Rates Viessmann Model Boilers Max. Flow Low -loss Flow Rate Temp. Rate Sensor Required 4t *1 OF 20 25 30 35 40 (0C) (11) (14) (17) (19.5) (22) 1321HIB 1 14.3 14.3 System Flow GPM 18.5 14.8 12.3 10.6 9.3 Included 57, (3250) (3250) Rate (L/h) (4201) (3361) (2801) (2401) (2101) 199 LLH Required Yes Yes OPT OPT OPT LLH Model 80/60 80/60 80/60 80/60 80/60 B2HB 2 14.3 28.6 System Flow GPM 37.0 29.6 24.7 21.1 18.5 Yes 57, (3250) (6500) Rate (L/h) (8403) (6722) (5602) (4802) (4201) 199 LLH Required Yes Yes Yes Yes Yes LLH Model 160/80 120/80 120/80 120/80 80/60 B2HB 3 14.3 42.9 System Flow GPM 55.5 44.4 37.0 31.7 27.8 Yes 57, (3250) (9750) Rate (L/h) (12604) (10083) (8403) (7202) (6302) 199 LLH Required Yes Yes Yes Yes Yes LLH Model 200/120 200/120 160/80 120/80 120/80 B2HB 4 14.3 57.2 System Flow GPM 74.0 59.2 49.3 42.3 37.0 Yes 57, (3250) (13000) Rate (L/h) (16805) (13444 (11204) (9603) (8403) 199 LLH Required Yes Yes Yes Yes Yes LLH Model 200/120 200/120 200/120 160/80 160/80 B2HB 5 14.3 71.5 System Flow GPM 92.5 74.0 61.7 52.9 46.3 Yes 57, (3250) (16250) Rate (L/h) (21007) (16805) (14005) (12004) (10503) 199 LLH Required Yes Yes Yes Yes Yes LLH Model 250/150 200/120 200/120 200/120 200/120 B2HB 6 14.3 85.8 System Flow GPM 111.0 88.8 74.0 63.4 55.5 Yes 57, (3250) (19500) Rate (L/h) (25208) (20166) (16805) (14405) (12604) 199 LLH Required Yes Yes Yes Yes Yes LLH Model 250/150 250/150 200/120 200/120 200/120 B2HB 7 14.3 100.1 System Flow GPM 129.5 103.6 86.3 74.0 64.8 Yes 57, (3250) (22750) Rate (L/h) (29409) (23528) (19606) (16805) (14705) 199 LLH Required Yes Yes Yes Yes Yes LLH Model 300/200 250/150 250/150 200/120 200/120 B2HB 8 14.3 114.4 System Flow GPM 148.0 118.4 98.7 84.6 74.0 Yes 57, (3250) (26000) Rate (L/h) (33611) (26889) (22407) (19206) (16805) 199 LLH Required Yes Yes Yes Yes Yes LLH Model 300/200 250/150 200/150 200/150 200/120 * 1 For system At < 20' F use low -loss header sizes for Lt 200 F. Co 00 00 Lo 13 DHW Production Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data Domestic Hot Water Production Vitodens 200-W boilers can be used in conjunction with the stand-alone DHW storage tanks offered by Viessmann. Size and select the DHW storage tank based on the forecasted DHW consumption of the building in question. For further technical information on DHW storage tanks, see the Vitocell Technical Data Manuals. Legend DR Boiler heating return for domestic hot water production DS Boiler heating supply for domestic hot water production HR Heating Return HS Heating Supply BD Boiler Drain BR Boiler Return BS Boiler Supply GC Gas Connection PRV Pressure Relief Valve BF Boiler Fill PG Pressure Gage (not shown) * 1 See page 45 for alternate DHW connection. *2 Temperature gauge For the connection of a stand-alone DHW tank, installation fittings (field supplied), an external circulating pump for DHW production (field supplied) and a DHW temperature sensor (optional equipment, see Viessmann Price List for order information) are required. PRV En n'a� BD *2 :::Y * 1 DHW Connections (Field Supplied) D =� DR I BR IMPORTANT An adequately sized pre -charged expansion tank must be used. See Installation Examples for details. Note: Install the temperature gauge (supplied) anywhere in the supply piping near the boiler (not shown). co 00 00 LO 14 Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data Domestic Hot Water Recirculation Vitocell stand-alone DHW storage tank Legend DCW Domestic Cold Water DHW Domestic Hot Water TPV Temperature and Pressure Relief Valve (on tank - not shown) R DHW Recirculation Line RP DHW Recirculation Pump a CO 00 CO Lo DHW Recirculation DHW recirculation lines increase the level of comfort and convenience of the domestic hot water supply and reduce water consumption. These advantages directly derive from the immediate availability of domestic hot water at all draw points. Poor insulation of the DHW recirculation line, however, can result in considerable heat loss. Viessmann therefore recommends that effective insulation be provided and used for DHW recirculation lines of 23 ft. (7 m) in length or longer. 15 Wall Mounting Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data Mounting Bracket r� .ter ®r s► (1975 mm) Models B2HB 19, 26, 35, 68, 94, 125 Fitting the wall mounting bracket See the installation instructions applicable to the mounting bracket on each type of material. 1. Remove the external accessories connection box cover. 2. Loosen the screws at the bottom of the boiler (do not remove completely). 3. Remove the front encloser panel (lift up and pull away from the boiler). 4. Mount boiler onto the mounting bracket and ensure the boiler is securely mounted. Connect boiler to the installation fittings. The boiler must be level both vertically and horizontally to ensure proper draining of the condensate. M CO W LO Lf) 16 Vitodens 200-W, 1321-113 19 to 57, 68 to 199 Technical Data Models 1321-113 45, 57, 160, 199 a CO 00 00 LO Wall Mounting 1. Remove the external accessories connection box cover. 2. Loosen the screws at the bottom of the boiler (do not remove completely). 3. Remove the front encloser panel (lift up and pull away from the boiler). 4. Mount boiler onto the mounting bracket and ensure the boiler is securely mounted. Connect boiler to the installation fittings. 5. Adjust the levelling screws to ensure the boiler is level. The boiler must be level both vertically and horizontally to ensure proper draining of the condensate. 17 Frame Mounting Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data Boiler Stand for B2HB 19 to 57, 68 to 199 I— e----I The boiler stand is used for free-standing installation of a single boiler within the mechanical room. When using the boiler stand, ensure that the stand is securely fastened to the floor (recommended concrete expansion anchors are Hilti model KB-TZ 3/8 x 4 or equivalent. a in. (mm) 19% (500) b in. (mm) 763/4±1/2 (1950±12.7) c in. (mm) 63±1/2 (1600±12.7) d in. (mm) 22 (560) e in. (mm) 24 (610) The Vitodens 200-W, model B2HB does not come with a mounting template. The wall location for the frame, mounting bracket and all vents must be field calculated. Boiler mounting bracket and frame 1. Attach the wall mounting bracket (supplied with the boiler) to the boiler mounting frame using the supplied hardware. Ensure that the wall mounting bracket is level. 2. Move the rack into position and secure to the floor (and to the wall if needed). CO CO CO Lo 18 Vitodens 200-W, 1321-113 19 to 57, 68 to 199 Technical Data Models 1321-113 45, 57, 160, 199 a M CO CO v in Wall Mounting 1. Remove the external accessories connection box cover. 2. Loosen the screws at the bottom of the boiler (do not remove completely). 3. Remove the front encloser panel (lift up and pull away from the boiler). 4. Mount boiler onto the mounting bracket and ensure the boiler is securely mounted. Then install the holding bracket to the frame on top of the boiler. 5. Adjust levelling screws to ensure the boiler is level. The boiler must be level both vertically and horizontally to ensure proper draining of the condensate. 19 Condensate Connection/Neutralization Unit Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data Condensate Connection Condensate Connection for Vitodens 200-W, models B2HB 19, 26, 35, 68, 94, 125 Install the condensate drain pipe with a suitable gradient. Discharge condensate from the boiler into the drainage system, either directly or (if required) via a neutralization unit (accessory). IMPORTANT Pipe ventilation must take place between the siphon trap and the neutralization unit (if applicable). Condensate Connection for Vitodens 200-W, models B2HB 45, 57, 160, 199 Condensate Drainage and Neutralization The condensate formed both in the condensing boiler and in the flue gas pipe must be discharged into the public sewage system in accordance with all applicable local regulations. The condensate produced by a gas -fired heating system has a pH value between 3 and 4. Some local codes may require the use of a separate neutralization unit to treat the aggressive and corrosive nature of the condensate. With a neutralization unit installed, all condensate from the boiler and the flue gas pipe enters into the neutralization unit where it is treated and released into the public sewage system with a safe pH value of above 6.5. The use of neutralization granulate (performing the neutralizing process) is dependent on the operation of the heating system. To determine the required refill amount, check granulate level several times during the first year of operation. In some cases one granulate fill may last an entire year. Contact Viessmann to order a neutralization unit for the Vitodens 200-W boiler. See Viessmann Price List for order information. The condensate discharge outlet to the drainage system connection must be clearly visible. It must be installed with a suitable gradient and provided with a stench trap. If the condensate outlet of the Vitodens 200-W boiler is lower than the drain, a condensate pump must be used. Only corrosion -resistant materials must be used for condensate drainage purposes (e.g. braided hose). Do not use galvanized materials or materials containing copper for piping, couplings etc. The condensate drain must have a trap to prevent flue gas leakage. Please note that other requirements might apply depending on local regulations and/or project -specific details. It is advisable to contact your local waterworks office (authority responsible for waste water regulations) well before commencing with the installation of the neutralization unit in order to establish details of local regulations that apply. The following table shows the concentration of (effluent) substances (e.g. heavy metals) contained in the waste water from the Vitodens 200-W condensing boiler. Condensate (effluent) Values measured in mg/L substances Vitodens 200-W Lead < 0.01 Cadmium < 0.005 Chromium < 0.01 Copper < 0.01 Nickel < 0.01 Zinc < 0.05 Tin < 0.05 co 00 00 LO 20 Vitodens 200-W, 1321-113 19 to 57, 68 to 199 Technical DaMenting Options/Electrical Connection/Control Venting Options For detailed information refer to the Installation Instructions for the Vitodens 200-W, B2HB Venting System. EM: Vent Connection, (with optional air intake openings on sides) for models B2HB 19, 26, 35, 68, 94, 125 Vent Connection, for models B2HB 45, 57, 160, 199 Electrical Connections Power Supply The Vitodens 200-W requires a standard 120VAC power outlet 15A fuse protected circuit. Refer to the installation instructions shipped with the boiler for wiring details, or reference the "Overview of Electrical Connections" on pages 44 to 47 of this manual. Power Supply Connection of Accessories The power supply connection of accessories can be made directly at the boiler control. The connection is activated and deactivated with the system on/off switch. The mixing valve accessory kit and the Vitosolic control (if used) will require a separate 120VAC power supply from the wall receptacle. co 00 00 LO Wire cabling required for: ■ Outdoor temperature sensor ■ Vitotronic 200-H, HK1 B mixing valve control ■ Accessory kit for heating circuit with mixing valve ■ Vitotrol 200A remote control ■ Vitotrol 300A remote control ■ Remote switching of operating mode ■ Remote disable ■ Alarm output 21 Boiler Control Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data On -Board Vitotronic 200, HO1 B Control Modular structure The control unit is integrated into the boiler. The control unit comprises a standard unit, electronics modules and a programming unit. Standard unit: ■ ON/OFF switch ■ Optolink laptop interface ■ Operating and fault indicators ■ Reset button ■ Fuses Programming unit: ■ Easy operation through: — Plain text display with graphic ability — Large font and black & white depiction for good contrast — Context -sensitive help text — Removable programming unit; can be mounted on the wall with separate accessory ■ With digital time switch ■ Control keys for: — Navigation — Confirmation — Help and additional information — Menu ■ Setting the: — Room temperature — Reduced room temperature — DHW temperature — Heating program — Time programs for central heating, DHW heating and DHW recirculation — Economy mode — Party mode — Holiday program — Heating curves — Codes — Actuator tests — Test mode ■ Displaying the: — Boiler water temperature — DHW temperature — Operating details — Diagnostic details — Fault messages co 00 00 LO 22 Vitodens 200-W, 132HB 19 to 57, 68 to 199 Technical Data Design and Function Functions ■ Weather -compensated control of the boiler water and/or supply temperature ■ Control of one heating circuit without mixer and two heating circuits with mixer ■ Control of one heating circuit without mixer and two heating circuits with mixer ■ Demand -dependent heating circuit pump and burner off control ■ Adjustment of a variable heating limit ■ Anti -seizing pump protection ■ Integral diagnostic system ■ Maintenance display ■ DHW temperature control with priority ■ Control of solar DHW heating and central heating backup in conjunction with the solar control module, type SM1 ■ Display of the solar energy yield ■ Auxiliary function for DHW heating (short-term heating to a higher temperature) ■ 0-10V External temperature setpoint signal input Control Characteristics PI characteristics with modulating output. Time Switch Digital time switch. ■ Individual and 7-day program ■ Automatic daylight savings time changeover ■ Automatic function for DHW heating and DHW recirculation pump ■ Time, day and standard switching times for space heating, DHW heating and the DHW recirculation pump are factory -set ■ Switching times are individually programmable, i.e. up to four switching periods per day Shortest switching interval: 10 minutes Power backup: 14 days. co 00 00 LO Boiler Control Setting the Operating Programs The heating system frost protection (see frost protection function) applies to all heating programs. You can select the following heating programs with the program keys: ■ Heating and DHW ■ DHW only ■ Standby mode External heating program changeover. Frost protection ■ The frost protection function will be started when the outside temperature drops below approx. 340F (1 °C). With the frost protection function, the heating circuit pump will be switched ON and the boiler water is maintained at a lower temperature of approx. 680F (20°C). The DHW tank will be heated to approx. 680F (201C). ■ The frost protection function will be stopped when the outside temperature rises above approx. 37°F (3°C) (default settings). Summer Operation Heating program "i" The burner is only activated upon a call for domestic hot water from the DHW storage tank (controlled by DHW tank temperature sensor). 23 Boiler Control Design and Functions (continued) Technical Data Rated supply voltage: 120VAC Rated frequency: 60 Hz Rated current: 12 A Max. ambient temp. - at operation: 32 to 1040F (0 to 40°C) Installation in living spaces or boiler rooms (standard ambient conditions) - when storing or transporting: -4 to + 1580F (-20 to + 70°C) Max. operating temp. setting (space heating): Models B2HB 19, 68 1650F (74°C) Models B2HB 26 to 57 180OF (82°C) and 94 to 199 DHW production: Models B2HB 19, 68 1650F (74°C) Models B2HB 26 to 57 180OF (82°C) and 94 to 199 Setting fixed high limit: 210°F (99°C) (not adjustable) Adjustment range of DHW tank set -point temperature: 50 to 1540F (10 to 68°C) Heating curve settings - Heating curve slope: 0.2 to 3.5 - Heating curve shift: -12 to +330C -13to40K . F NOW i%!/f:O!- P' P'1d;P ■■■ ��iJaO%�%��_�■����NOF Legend 0 Low temperature heating system, e.g. radiant floor heating © Medium temperature heating system, e.g. cast iron radiation, staple -up radiant floor heating © High temperature heating system, e.g. fintube radiation, fan coils Vitodens 200-W, 132HB 19 to 57, 68 to 199 Technical Data Heating Curve Adjustment (slope and shift) The control unit regulates the boiler water temperature ( = supply temperature of heating circuit without mixing valve) and the supply temperature of the heating circuit with mixing valve (in conjunction with the accessory mixing valve extension kit) according to the outdoor temperature. The boiler water temperature is automatically raised by 0 to 72 F / 0 to 40 K higher than the currently required set supply temperature (in the factory default setting the differential temperature is 14.4 F / 8 K). See Service Instructions for coding address "9F" in coding level 2. The supply temperature that is required to achieve a given room temperature depends on the heating system and the thermal insulation of the building that is being heated. The adjustment of the two heating curves is used to match the boiler water temperature and the supply temperature to these conditions. The boiler water temperature is limited upwards by the fixed high limit and the temperature set for the electronic high limit. The supply temperature cannot rise above the boiler water temperature. a CO 00 CO Lo 24 Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data Sensors (supplied) Boiler Temperature Sensor The boiler temperature sensor is connected at the control unit for weather -responsive operation and is built into the boiler. Specification sensor type: Viessmann NTC 10K ohms at 77°F (25°C) Max. ambient temp. - at operation: 32 to 2660F (0 to 1300C) - when storing or transporting: - 4 to + 1580F (-20 to + 70°C) DHW Tank Temperature Sensor (immersion temperature sensor) Supplied with: - Cable length approx. 13 ft. (3.75 m), ready to plug in - All pipe connections are field supplied. Specification Max. ambient temp. - at operation: - when storing or transporting: - Sensor type 32 to 1940F (0 to 90°C) - 4 to + 1580F (-20 to + 70°C) Viessmann NTC 10K ohms @ 770F (25°C) Immersion Temperature Sensor To capture the low loss temperature (if low -loss header is used) Specification Lead length fully wired: 12 ft. (3.75 m), Permissable ambient temp. - during operation: 32 to 1941F (0 to 90°C) - when storing or transporting: - 4 to+1580 F (-20 to+700 C) co 00 00 LO Accessories Outdoor Temperature Sensor Sensor location: - North or northwest wall of building - 6.6 to 8.2 ft. (2 to 2.5 m) above ground or in case of a multi-storey building approximately halfway up the second floor Electrical connection: - 2-wire cable, max. cable length 115 ft. (35 m) with a wire size of min. AWG 16 copper - Cable to the outdoor sensor must not be laid near line voltage wiring (120/240 V) Max. ambient temperature during transport, storage and operation: -40 to 1940F (-40 to 90°C) 25 Accessories Optional Accessories Supply Temperature Sensor (strap -on sensor, included with mixing valve actuator accessory kit), - when storing or transporting: -4 to+ 1580F (-20 to+70°C) Installed with a strapping band. Cable length 19.7 ft. (6 m), ready to plug in. Max. ambient temp. - at operation: 32 to 2120F (0 to 100°C) - when storing or transporting: -4 to + 1490F (-20 to + 70°C) Room Temperature Sensor, f�g Separate room temperature sensor as supplement to the Vitotrol and 300A; to be used if the 300A cannot be installed inside the main living room or in a suitable position where the unit can capture and adjust the temperature. Installation in the main living room on an internal wall opposite radiators. Never install inside shelf units, recesses, immediately by a door or heat source (e.g. direct sunlight, fireplace, TV set, etc.). Connect the room temperature sensor to the Vitotrol 300A. Electrical connection: - 2-wire cable with a wire size of min. AWG 18 copper - The cable length between the control unit, remote control unit and room temperature sensor must not exceed 98 ft. (30 m) Max. ambient temp. - at operation: 32 to 1040F (0 to 40°C) - when storing or transporting: -4 to+ 1490F (-20 to +65°C) Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data Mixing Valve Motor Kit 6 1130 The mixing valve actuator is mounted directly on the Viessmann % to 2'/z " mixing valve. The mixing valve actuator is a motor -driven control unit. The rotational direction is reversible. Rated voltage: 120VAC Rated frequency: 60 Hz Power consumption: 4W max. ambient temperature - at operation: 320F to 1040F (0°C to 40°C) application in living areas and installation sites (normal ambient conditions) -storage & shipping: -40F to 149OF (-20°C to 65°C) co 00 00 LO 26 Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data Optional Accessories (continued) Mixing Valve Extension Module 6 117 Rated voltage: 120VAC Rated frequency: 60 Hz Rated current: 2 A Power consumption: 4 W Max. ambient temp. - at operation: 32 to 1040F (0 to 40°C) - when storing or transporting: -4 to + 1490F (-20 to + 65°C) Relay output for heating circuit pump: 2 A, 120VAC Actuator torque: 3 Nm Time of 90°: 120 seconds LON Communication Module Electronic PCB for data exchange with the Vitotronic 200-H, Vitocom 200 and for connecting to a higher level building management system. LON Connecting Cable (for data exchange between control units) Cable length 23 ft. (7 m), fully wired LON Terminal End Resistor To terminate the LON BUS at the first and the last control unit. a co 00 co Lo Accessories KM BUS Expansion Module To connect 2 to 9 devices (mixing valve actuator, Vitotrol, input module, etc.) to the single KM BUS connection of the boiler. Specification Lead length 10 ft. (3.0 m), fully wired Permissable ambient temp. - during operation 32 to 1040F (0 to 40°C) - during storage and transport: - 4 to+1490F (-20 to+65°C) 27 Accessories Optional Accessories (continued) Vitotrol 200A One Vitotrol 200A can be used for every heating circuit in a heating system. The Vitotrol 200A can regulate one heating circuit and up to two remote controls may be connected to the control unit. KM BUS Participant The Vitotrol 200A remote control regulates the required set room temperature in standard mode, from any room in the house. Party and economy mode can be enabled via keys Only for heating circuit with mixing valve Fitted room temperature sensor for room temperature hook-up WS function: Installation anywhere in the building. RS function: Note: Never activate the RS function for underfloor heating circuits (inertia). In heating systems with a heating circuit without mixing valve and heating circuits with mixing valve, the RS function must only affect the heating circuit with mixing valve. Room temperature hook-up: Installation in the main living room on an internal wall opposite radiators. Never install inside shelf units, recesses, immediately by a door or heat source (e.g. direct sunlight, fireplace, TV set, etc.). The integral room temperature sensor captures the actual room temperature and effects any necessary corrections of the supply temperature as well as a rapid heat -up at the start of the heating operation (if appropriately programmed). 28 Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data Connection: 2-core lead 18 AWG, length max. 164 ft.(50 m) (even if connecting several remote control units) Never route this lead immediately next to 120/208/460 V cables LV plug as standard delivery must be installed in the main living room (lead room). Specification: Power supply via KM BUS Power consumption: 0.2 W Max. ambient temp. - at operation: 32 to 1040F (0 to 40°C) - when storing or transporting: -4 to + 1490F (-20 to + 65°C) Set room temp. range 37 to 990F (3 to 37°C) The set room temperature for reduced mode is adjusted at the control unit. co 00 00 LO Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data Optional Accessories (continued) Vitotrol 300A One Vitotrol 300A can be used for every heating circuit in a heating system. The Vitotrol 300A can regulate up to three heating circuits. Up to two remote controls may be connected to the control unit. KM BUS Participant The Vitotrol 300A remote control regulates the required set room temperature for one heating circuit in standard and reduced mode, the heating program and the switching times for central heating, DHW heating and the DHW recirculation pump. Displaying: Room temperature Outside temperature Heating program Operating condition Solar yield as graphic display Settings: Set room temperatures for standard mode (day temperature) and reduced mode (night temperature) via the standard display Heating program, switching times for heating circuits, DHW heating and DHW recirculation pump plus further settings via plain text menu on the display Party and economy mode can be enabled via the menu Only for heating circuit with mixer: Fitted room temperature sensor for room temperature hook-up Note: For room temperature hook-up, the Vitotrol 300A must be installed in the main living room (lead room). co 00 co Lo Accessories RS function: Installation in the main living room on an internal wall opposite radiators. Never install inside shelving units, in recesses, or immediately by a door or heat source (e.g. direct sunlight, fireplace, TV set, etc.). The fitted room temperature sensor captures the actual room temperature and effects any necessary correction of the flow temperature. WS function: Installation anywhere in the building. Connection: 2-core lead 18 AWG, length max. 164 ft. (50 m) (even if connecting several remote control units) Never route this lead immediately next to 120/208/460V cables LV plug as standard delivery must be installed in the main living room (lead room). Specification: Power supply via KM BUS Power consumption: 0.2 W Max. ambient temp. - at operation: 32 to 1040F (0 to 40°C) - when storing or transporting: -4 to + 1490F (-20 to + 65°C) Set room temp. range 37 to 990F (3 to 37°C) The set room temperature for reduced mode is adjusted at the control unit. 29 Accessories Accessories for Vitodens 200-W LON Communication Module Electronic PCB for data exchange with the Vitotronic 200-H, Vitocom 200 and for connecting to a higher level building management system. Neutralization Unit for Single -Boiler Applications with neutralizing granulate for models B2HB 19, 26, 35, 68, 94, 125 III Ill �� for models B2HB 45, 57, 160, 199 Neutralization Pellets for models 1321­16 19, 26, 35, 45, 57, 68, 94, 125, 160, 199 2 x 1.3 kg for refill or replacement purposes Vitodens 200-W, 1321­113 19 to 57, 68 to 199 Technical Data Fuel Conversion Label Kit (NG>LPG) (included in boiler technical literature set) The Vitodens 200-W, B2HB boiler comes factory set for operation with natural gas. All B2HB models can be field converted to operate with liquid propane gas (as well as back to natural gas as required). The kit includes instructions and labels for field conversion. Low -Loss Header When used in conjunction with the Vitodens 200-W boiler, the low -loss header acts as hydraulic break, decoupling boiler and system circuits from each other. It is recommended to use the low -loss header in applications in which the total system flow rate exceeds the maximum (or minimum) boiler flow rate. For maximum boiler flow rates, starting on page 10 of this manual. Viessmann strongly recommends the use of a low -loss header in cases where the system head and flow rates are unknown. The temperature sensor connection [TS1 typically located at the top of the low -loss header ensures low return temperatures to the Vitodens 200-W boiler at all times, increasing operational efficiency. In addition, the low -loss header helps eliminate air and debris [D] from the heating system. See illustrations for design and principle of operation on page 31. The low -loss header is available in various sizes (see page 31). Select the size based on the maximum system flow rate of your application. co 00 00 LO 30 Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data Accessories for Vitodens 200-W Low -Loss Header (continued) Low -loss header design (Typical) Sc 1 — AB SW • IF /4 SS BS Ts BY SR - .000 ~ • • •' • DV BR Principle of Operation T1 T3 Vprimary Vbypasst T4 Vsac: Weis y T2 T4 00 00 LO Accessories IMPORTANT Use only a Viessmann supplied temperature sensor. Do not use any other manufacturer's temperature sensor. Legend AB Air Bleed BR Boiler Return BS Boiler Supply BY Bypass (with laminar flow) D Debris DV Drain Valve SC Sensor Cable SR System Return SS System Supply TS Viessmann Temperature Sensor SW Sensor Well IMPORTANT When installing a low -loss header, the system mixed supply temperature (T3) must be calculated as follows: T1 x Vprimary+T4 Vbypass T3= V sec onda ry Legend T1 Boiler supply temperature T2 Boiler return temperature T3 System supply temperature T4 System return temperature Vprimary Boiler circuit flow rate Vsecondary Heating circuit flow rate Vbypass Bypass flow rate Qprimary Heat supplied by boiler Qsecondary Heat consumed by system Vprimary < Vsecondary T1 > T3 T2 = T4 Qprimary = Qsecondary T1 1670F (750C) Vsecondary = Vprimary + Vbypass Model No. Max. system flow rate Type 80/60 19.5 GPM (4.4 m3/h) Type 120/80 35.2 GPM (8 m3/h) Type 160/80 * 1 44 GPM (10 m3/h) Type 200/120 * 1 80 GPM (18 m3/h) * 1 Floor -mounted version (typically used for multiple -boiler installations). 31 Standard Equipment Standard Equipment The Vitodens 200-W gas -fired condensing boiler with Inox-Radial heat exchanger, modulating MatriX cylinder burner for liquid propane gas and natural gas (available on all models), comes standard with: ■ pressure gauge ■ installation fittings with 30 psig pressure relief valve and air vent ■ thermometer gauge (field installation on supply pipe) ■ LLH immersion sensor (if LLH is used) ■ DHW sensor ■ boiler control unit with outdoor temperature sensor The boiler comes prewired and fully piped internally for field connections and prewired. Side wall co -axial vent installations must include Viessmann protective screen! Enclosure finish: black steel, powder -coated white The Vitodens 200-W comes ready for use with natural gas and can be fuel converted to liquid propane gas in the field. Air vent Combustion Management System The combustion management system utilizes the physical correlation between the level of the ionization current and the air factor A. For all gas qualities, the maximum ionization current results with air factor A. The ionization signal is evaluated by the combustion management system, and the air factor is adjusted to between A= 1.24 and 1.44. This range provides for an optimum combustion quality. Thereafter, the electronic gas valve regulates the required gas volume based on the prevailing gas quality. To check the combustion quality, the CO2 content or the 02 content of the flue gas is measured. The actual values enable the prevailing air factor to be determined. The relationship between the CO2 or 02 content and air factor A is illustrated in the table below. Air factor k - CO2/02 content Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data Wall mounting componentry The following wall mounting components are supplied with the Vitodens 200-W boiler: ■ Mounting bracket ■ Mounting bolts ■ Installation fittings Screws for mounting bracket on wood studs (2" x 4") metal studs brick/concrete wall To achieve an optimum combustion control, the system regularly performs an automatic self -calibration; also after a power failure (shutdown). For this, the combustion is briefly regulated to max. ionization current (equals air factor A = 1). The automatic calibration is performed shortly after the burner starts and lasts approximately 5 seconds. During the calibration, higher than normal CO emissions may occur briefly. Air factor k 02 content M CO2 content M for natural gas CO2 content M for liquid propane gas 1.20 3.8 4.4 9.6 11.3 1.24 9.2 10.9 1.27 4.9 9.0 10.6 1.30 5.3 8.7 10.3 1.34 5.7 8.5 10.0 1.37 6.1 8.3 8.1 7.8 9.8 9.6 9.3 1.40 6.5 1.44 6.9 1.48 7.3 7.6 9.0 The Vitodens 200-W, B2HB boilers come equipped with Lambda Pro, the industry's first intelligent combustion management system. The boiler adjusts automatically to any gas type and quality without the need for a fuel conversion kit. 00 CO Lo 32 Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data Hydraulic Connection Installation Examples Installation System design Viessmann condensing boilers can generally be installed in any pumped hot water heating system (closed system). The circulation pump is an integral part of the appliance. Minimum system pressure 14 psi (1.0 bar). The boiler water temperature is limited to 1650F (74°C) for for models 19, 68 and 180OF (82°C) for models 26 to 57 and 94 to 199. To minimize distribution losses, we recommend that you size the heat distribution system to a max. supply temperature of 1580F (70°C). To reduce burner cycling in low energy houses with a correspondingly low heat demand, we recommend the use of a low loss header. Please note that in the following piping layout examples all pumps are field supplied. IMPORTANT IMPORTANT The examples on the following pages depict possible piping layouts of the Vitodens 200-W boiler equipped with Viessmann System Technology. For boiler and tank combinations, please install only feasible combinations listed in the Viessmann Price List Please note that the following examples are simplified conceptual drawings only! Piping and necessary componentry must be field verified A low water cut-off (LWCO) must be installed where required by local codes. Proper installation and functionality in the field is the responsibility of the heating contractor. a co 00 co LO DHW supply and return piping between boiler DHW connections and the Viessmann DHW tank connections, shall be a minimum of 1" nominal pipe diameter (for models B2HB 19 to 35, 68 to 125), nominal pipe diameter of 11/2" for models B2HB 45, 57, 160, 199) DHW connection outlet sizes provided on the boiler and the DHW tank). This will ensure the residual head of the field supplied pump is fully utilized to overcome the resistance of the DHW heat exchanger coil and to provide sufficient water flow to the boiler heat exchanger. In non-Viessmann DHW tank applications, perform, in addition to the above, accurate calculations for DHW tank coil pressure drop versus boiler pump (field supplied) residual head to ensure sufficient water flow to the boiler heat exchanger. Failure to heed the above instructions may cause boiler short -cycling and inadequate DHW supply. 33 Installation Examples System Layout 1 Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data Vitodens 200-W, B2HB with a direct -connected heating circuit Legend (2 Vitodens 200-W B2HB boiler with Vitotronic 200, HO1 B outdoor reset control © Outdoor temperature sensor 0 © Vitotrol remote (optional) Heating circuit Q Heating circuit pump 20 Q DHW circulating pump 21 © DHW storage tank DHW tank temperature sensor 0 Expansion tank Q Flow check valve DHW recirculation pump 2ai2o © Temperature and pressure relief valve Pressure relief valve Function based on coding of address 53 Installation of ... ■ radiator heating circuit (high -temp. circuit) ■ DHW production ... with the following flow conditions: The flow rate of the heating circuit is less than the maximum possible water flow rate of the Vitodens 200-W B2HB boiler (see page 10 for maximum water flow rate of boiler). The use of a low -loss header is strongly recommended if the maximum water flow rate in the application concerned exceeds the values shown in the applicable table on page 10, or if the system flow rates are unknown. The low -loss header is available as accessory part. See following pages for installation examples with a low - loss header. IMPORTANT DHW circulating pump 0 must pump into the Vitodens Co 200-W boiler (as illustrated). °' LO 34 Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data Installation Examples System Layout 2 Vitodens 200-W, B2HB with one heating circuit and low -loss header Legend Vitodens 200-W B2HB boiler with Vitotronic 200, HO1 B outdoor reset control © Outdoor temperature sensor Fil © Vitotrol remote (optional) OD Heating circuit OE Boiler pump 20 OF DHW circulating pump [] © DHW storage tank OH DHW tank temperature sensor ❑5 OI Expansion tank Temperature and pressure relief valve OK DHW recirculation pump 2s/2o © Low -loss header Pressure relief valve Viessmann temperature sensor for low -loss header ❑2 @0 Heating circuit pump 2s/2o 0 * Function based on coding of address 53 LO U Installation of ... ■ radiator heating circuit (high -temp. circuit) ■ DHW production ... with the following flow conditions: The flow rate of the heating circuit is greater than the maximum possible water flow rate of the Vitodens 200-W B2HB boiler (see page 10 for maximum water flow rate of boiler). The use of a low -loss header is strongly recommended if the maximum water flow rate in the application concerned exceeds the values shown on page 10, or if the system flow rates are unknown. The low -loss header is available as accessory part. IMPORTANT Please note location of expansion tank. DHW circulating pump ( must pump into the Vitodens 200-W B2HB boiler (as illustrated). 35 Installation Examples System Layout 3 Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data Vitodens 200-W, B2HB with... DHW storage tank one heating circuit with mixing valve and system separation 0 r o w J 0 Q :j + jl I j 1 I Legend Vitodens 200-W B2HB boiler with Vitotronic 200, HO1 B outdoor reset control © Outdoor temperature 0 © Vitotrol remote (optional) Underfloor heating circuit Mixing valve temperature sensor E2] Pressure relief valve © Plate heat exchanger for system separation Accessory kit for heating circuit with mixing valve DHW circulating pump E2] 0 DHW storage tank DHW tank temperature sensor ❑5 © Expansion tank DHW recirculation pump 2s/2o Temperature and pressure relief valve Flow check valve © Heating circuit pump 20 © Heating circuit pump Function based on coding of address 53 IMPORTANT DHW circulating pump must pump ID into the Vitodens 200-W B2HB boiler (as illustrated). 36 I I I $o I I I I I I I I I ------------ Installation of ... ■ underfloor heating circuit with 3-way mixing valve and system separation (low -temp. circuit) ■ DHW production ... with the following flow conditions: The flow rate of the heating circuit is less than the maximum possible water flow rate of the Vitodens 200-W B2HB boiler. See page 10 for maximum water flow rate of the Vitodens 200-W B2HB boilers. The use of a low -loss header is recommended if the system water flow rate is unknown. The low -loss header is available as accessory part. See following pages for installation examples with a low -loss header. IMPORTANT System separation is required of underfloor heating systems employing non -oxygen diffusion barrier tubing. All components on the secondary side of the heat exchanger must be made of corrosion -resistant materials. IMPORTANT Sizing of field -supplied pump © is critical for proper boiler operation in this system layout. See page 9 for the supply head pressure drop of the boiler. An undersized pump may cause short -cycling and/or improper operation of the boiler. 00 Viessmann STRONGLY recommends using a low -loss Co header and a boiler pump in this system layout. Lo Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data System Layout 4 Vitodens 200-W, B2HB with... DHW storage tank one direct -connected heating circuit one heating circuit with a mixing valve Installation Examples 4 I I I j I r I I I --J •-J I j �1 I I I JI I I I I Q I I i I I � I I � —'� I I I 1 N � 1 � I I -_© ©J I I I I I I I I r-------J------------------a--------J I I Legend Vitodens 200-W B2HB boiler with Vitotronic 200, H01 B outdoor reset control © Outdoor temperature sensor 1❑ © Vitotrol remote (optional) Under floor heating circuit Radiator heating circuit OF Heating circuit pump © Mixing valve temperature sensor ❑2 Accessory kit for heating circuit with mixing valve �i Domestic hot water storage tank DHW tank temperature sensor ❑5 OK Expansion tank © Temperature and pressure relief valve Pressure relief valve ON DHW recirculation pump 28/2 @0 Boiler pump 20 © DHW circulating pump [2] Function based on coding of address 53 IMPORTANT DHW circulating pump © must pump into the Vitodens 200-W B2HB boiler (as illustrated). 00 00 LO Installation of ... ■ underfloor heating circuit with 3-way mixing valve and system separation (low -temp. circuit) ■ DHW production ... with the following flow conditions: The flow rate of the heating circuit is less than the maximum possible water flow rate of the Vitodens 200-W B2HB boiler. See page 10 for maximum water flow rate of the Vitodens 200-W B2HB boilers. The use of a low -loss header is recommended if the system water flow rate is unknown. The low -loss header is available as accessory part. See following pages for installation examples with a low -loss header. IMPORTANT System separation is required of underfloor heating systems employing non -oxygen diffusion barrier tubing. All components on the secondary side of the heat exchanger must be made of corrosion -resistant materials. IMPORTANT Sizing of field -supplied pump © is critical for proper boiler operation in this system layout. See page 9 for the supply head pressure drop of the boiler. An undersized pump may cause short -cycling and/or improper operation of the boiler Viessmann STRONGLY recommends using a low -loss header and a boiler pump in this system layout. 37 Installation Examples System Layout 5 Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data Vitodens 200-W, B2HB with... DHW storage tank one heating circuit with mixing valve one heating circuit without mixing valve and low -loss header Legend Vitodens 200-W B2HB boiler with Vitotronic 200, H01 B outdoor reset control © Outdoor temperature sensor [1] © Vitotrol remote (optional) Under floor heating circuit Radiator heating circuit OF Boiler circuit pump 20 © Mixing valve temperature sensor ❑2 Kit for heating circuit with mixing valve �i Domestic hot water storage tank DHW tank temperature sensor ❑5 OK Expansion tank © Temperature and pressure relief valve Pressure relief valve ON DHW recirculation pump 28/20 @0 DHW circulating pump E2] © Heating circuit pump © Low -loss header ® Viessmann temperature sensor for low -loss header ❑2 �S Heating circuit pump 28/20 Function based on coding of address 53 Installation of different heating circuits... ■ radiator heating circuit (high -temp. circuit) ■ under floor heating circuit with 3-way mixing valve (low -temp. circuit) ■ DHW production ... with the following flow conditions: The total flow rate of the two heating circuits is greater than the maximum possible water flow rate of the Vitodens 200-W B2HB boiler (see page 10 for maximum water flow rate of boiler). The use of a low -loss header is strongly recommended. The low -loss header is available as accessory part. The 3-way mixing valve, built-in to achieve the low - temperature level of the under floor heating circuit, is controlled by an accessory kit for a heating circuit with mixing valve. IMPORTANT DHW circulating pump @0 must pump into the Vitodens 200-W B2HB boiler (as illustrated). Co 00 Co Lo 38 Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data System Layout 6 Vitodens 200-W, B2HB with... DHW storage tank one heating circuit without a mixing valve two heating circuits with a mixing valve low -loss header I I r- — — — — — — — - F— I 0 Legend Vitodens 200-W B2HB boiler with Vitotronic 200, H01 B outdoor reset control © Outdoor temperature sensor 1❑ © Vitotrol remote (optional) Under floor heating circuit OE Heating circuit pump 28/20 * OF Mixing valve temperature sensor ❑2 © Accessory kit for heating circuit with mixing valve OH Heating circuit pumps OI DHW storage tank DHW tank temperature sensor ❑5 OK Expansion tank © Temperature and pressure relief valve Low -loss header Viessmann temperature sensor for low -loss header ❑2 @0 Pressure relief valve © DHW recirculation pump 28/20 © Radiator heating circuit ® Boiler pump 2-o �S DHW circulating pump F2211 Function based on coding of address 53 Co 00 00 LO Installation Examples U p U p v I I o t I I G I G I — — — — �— I air a -cT*-J I I I I I I I I I I I 1 I I I � I I I I 1 I I 1 I I I I I I I I I ------L--------1-------- I I J 0 Installation of different heating circuits... ■ two heating circuits with 3-way mixing valve (low -temp. circuit) ■ DHW production ... with the following flow conditions: The total flow rate of the two heating circuits is greater than the maximum possible water flow rate of the Vitodens 200-W B2HB boiler (see page 10 for maximum water flow rate of boiler). The use of a low -loss header is strongly recommended. The low -loss header is available as accessory part. The 3-way mixing valve, built-in to achieve the low - temperature level of the under floor heating circuit, is controlled by an accessory kit for a heating circuit with a mixing valve. IMPORTANT DHW circulating pump s0 must pump into the Vitodens 200-W B2HB boiler (as illustrated). 39 Installation Examples Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data System Layout 7 Vitodens 200-W, B2HB with... direct -connected heating circuit one heating circuit with system separation ©© (9 U o Q 4 a I T I 1 I I I I , I, I ___ 71� 1° I I ° I i I I o I - -0 J - I I I I I I r-------J------------------1--------J Io-on Legend Vitodens Vitodens 200-W B2HB boiler with Vitotronic 200, HO1 B outdoor reset control © Outdoor temperature sensor El © Vitotrol remote (optional) Under floor heating circuit Radiator heating circuit Plate heat exchanger for system separation © Heating circuit pump °H Mixing valve temperature sensor ❑2 °i Accessory kit for heating circuit with mixing valve DHW storage tank °K DHW tank temperature sensor ❑5 © Expansion tanks Temperature and pressure relief valve Pressure relief valve °O DHW recirculation pump 28/20 © Boiler pump 20 © DHW circulating pump E2] Function based on coding of address 53 IMPORTANT DHW circulating pump © must pump into the Vitodens 200-W B2HB boiler (as illustrated). Installation of different heating circuits... ■ radiator heating circuit (high -temp. circuit) ■ under floor heating circuit with 3-way mixing valve (low -temp. circuit) ■ DHW production ... with the following flow conditions: The total flow rate of the two heating circuits is less than the maximum possible water flow rate of the Vitodens 200-W B2HB boiler (see page 10 for maximum water flow rate of boiler). The use of a low -loss header is strongly recommended if the maximum water flow rate in the application concerned exceeds the max. boiler flow rate, or if the system flow rates are unknown. The low -loss header is available as accessory part. The 3-way mixing valve, built-in to achieve the low - temperature level of the under floor heating circuit, is controlled by an accessory kit for a heating circuit with mixing valve 0. The boiler pump 20 supplies the radiator heating circuit and the plate heat exchanger for system separation. IMPORTANT The pressure drop (secondary circuit) of the plate heat exchanger °F must be less/equal to the pressure drop of Co the 3-way mixing valve. This must be taken into account 00 when sizing the plate heat exchanger. 40 a Lo Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data System Layout 8 Vitodens 200-W, B2HB with... DHW storage tank low -loss header multiple heating circuits with mixing valves one heating circuit without mixing valve 0 Q I r — Installation Examples ® o 0 0 0 0 0 I � " 4 11 � I I I r I I I r I I I I y I I I G I G I _..——..—.1—.. a bTo- J -Ao- a I I I I I I I I I I I I I I I I I I 1 I I J I I I I I I I I I I I I ------L---------1------_-1--------.i I I I I I I When designing a system as illustrated above, please contact your local Viessmann Sales Representative for assistance. Legend Vitodens 200-W B2HB boiler with Vitotronic 200, HO1 B outdoor reset control © Outdoor temperature E1] © Boiler pump 20 OD Vitotronic 200-H, HK1 B * 1 OE Mixing valve temperature sensor E21 OF Heating circuit pumps © Accessory kit for heating circuit with mixing valve 9 Heating circuits with mixing valves Di Viessmann temperature sensor for low -loss header E2 Q Low -loss header OK DHW circulating pump E2] © DHW tank temperature sensor ❑5 OM DHW storage tank ON Expansion tank @O DHW recirculation pump E2] © Heating circuit pump 28/20 * © Vitotrol remote (optional) ® Radiator heating circuit �S Temperature and pressure relief valve ni Pressure relief valve Function based on coding of address 53 co 00 00 LO * 1 Contact your local Sales Representative for details. Vitotronic 200-H, H K 1 B mixing valve control with LON communication module can be used instead of the accessory kit and Vitocontrol. IIMPORTANTT Please note location of expansion tank �. IMPORTANT Pumps © and (9) must pump into the Vitodens 200-W B2HB boiler (as illustrated). 41 Installation Examples System Layout 9 Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data Multiple (up to eight) Vitodens 200-W, models B2HB 45, 57, 160, 199 with... multiple heating circuits with mixing valves low -loss header L-____-______ ______________________________ ' Legend Vitodens boiler © Vitotronic 300K © Low -loss header/common supply temperature sensor Low -loss header DHW storage tank High temperature heating circuit © Low temperature heating circuit When designing a multiple Vitodens system as shown above, please reference applicable multiple Vitodens technical documentation, and contact your local Viessmann Sales Representative for further assistance. This installation example depicts a possible piping layout for multiple Vitodens 200-W, B2HB boilers equipped with Viessmann System Technology. Please note that this example is based on a simplified conceptual drawing only! Piping and necessary componentry must be field verified. A low water cut-off (LWCO) must be installed where required by local codes. Proper installation and functionality in the field is the responsibility of the heating contractor. M CO CO 7D It LO 42 Vitodens 200-W, 1321-113 19 to 57, 68 to 199 Technical Data Installation Examples Alternative DHW Connection The following piping diagram reflects an alternative connection for the DHW tank only and applies to system layouts 2, 5, 6 and 8. The boiler control pump logic function must be programmed in the Service Instructions. L J *Note: When using a low loss header in the system, the DHW connections can be made downstream of the low loss header. See Vitodens 200-W B2HB Service Instructions for applicable system coding information (see coding level 2): 00:... A2:... 5b:... M 00 00 G LO 43 Wiring Diagram Vitodens 200-W, 1321-113 19 to 57, 68 to 199 Technical Data Overview of Electrical Connections, Models 1321-113 19, 26, 35, 68, 94, 125 r- r K6 0 N0 —MBi—N®i—NBA—N®� — l N� NMI NMI I I I 15" _ — I r;1 x6.] 93R I I 1••i k5., % +I i K,•x I K8 ■ KZ KB KI r1—�+81 IKill Al2 xe.,e L-- I r� A� O I I , 1 Ar.. I. k9., aL_4.. SOVO 1 . — J - x,o LA2_ J- L8.—..J �L�.!1 ......1 LA5 11 J F FQAA1 II . J J-7,— LIII���J L.J ' �I II I� m2mr, ■ © 11 11 DISCONNECT POWER BEFORE Label all wires prior to disconnection SERVICING BOILER. when servicing controls. Wiring errors can cause improper and dangerou • - • • operation. Verify proper operation • • • • • • after servicing. 44 Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data Wiring Diagram Overview of Electrical Connections, Models 1321-113 19, 26, 35, 68, 94, 125 (continued) Legend 0 Outdoor Temperature Sensor 0 Supply Temperature Sensor/Low Loss Header 0 Boiler Temperature Sensor 0 DHW Temperature Sensor 11 Ionization Electrode 15 Flue Gas temperature Sensor 20 Boiler Pump 21 DHW Pump [21 ] Pump Output Connection 28/20 Programmable Pump Output* 33 Flow Switch 35 Gas Valve 40 Power Supply 40A Accessory Power Output 47 Fixed High Limit [53] Powered Accessory Connection 54 Ignition Transformer 96 Powered Accessory Connection 100 Fan Motor 100A Fan Motor Control 1 11 Not Used 145 KM BUS Multi Powered Accessory Connection 156A Switched Output F2 156B Switched Output F1 DE1 Digital Input 1 (Dry Contact) DE2 Digital Input 2 (Dry Contact) DE3 Digital Input 3 (Dry Contact) 0 10 0-10VDC Input 157 Fault Alarm/DHW Recirc. Pump* 190 Gas Modulation Coil * See wiring diagram AO Boiler Control © External Accessory Connection Board © Pump Connection Interface O� Extension Module EA1 © KM -BUS for External Devices © Electrical Junction Box © Field Wiring Connections Al Main Board A2Internal Power Supply Unit A3 Optolink A4 Burner Control Unit A5 Programming Unit A6 Coding Card A7 Connection Adaptor A8 LON Communication Module S1 ON/OFF Switch S2 Reset Button X.. Electrical Interface co 00 00 IMPORTANT Electrical installations must comply with the latest edition of: ■ In the U.S.A., the National Electrical Code (NEC), ANSI/NFPA 70 and any other state, local codes and/or regulations. ■ In Canada, the Canadian Electrical Code (CEC), CSA C22.1 Part 1 and any other province, territory, local codes and/or regulations. LO LO 45 Wiring Diagram Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data Overview of Electrical Connections, Models 1321-113 45, 57, 160, 199 0 MW U11 If - '44 �t-jl i-1-1 H'DL H®L HOL ROL R®el , Y Y 19 —Y—YY— Y-Y—Y—Y—Y— YkX LtiH® —��I I H`®'L , RI®L YKKYYYY I I F- � L6..J �•s L .. — .. J AL.. xl J t• •+�12 -- &9R 15onF I - xt I r1 - g1 x„ [ L`� I Al r. —..7 L rig trig �x= A3aMo �.. I. x,D LA2— .. �� Sig .7 r.. Y 0 O �� •I %fl 2%L1R%51y x2S y7P IL®k X®L E L PE i L PE L PE i L PE L PE L PE L PE L PE 120V�6uH ,� Kilo) ®N i * ® I 55 • MALT- 86•YD * ® 70 © 5B9 �0 I II met �I I o ! LL_ - JJ �(�---------------- L© -- — -- J,fi WARNING A CAUTION I I rI " I P2 I LL I L[ L8 POWER BEFORE Label all wires prior to disconnection BOILER.DISCONNECT SERVICING RA[ry o[SCuI•MECi I I SV[LCHcan I If any of the original wires as cause improper . • dangerous LG4 I Ra[k P[]VER SUPPz I �0 "" 60 Z I L _ _ 12 Amps [FWI Load Amperage[ J supplied with the appliance must after servicing. be replaced, it must be replaced Only one function/accessory may with the exact equivalent. be assigned to each connection. 00 00 46 Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data Wiring Diagram Overview of Electrical Connections, Models 1321-113 45, 57, 160, 199 (continued) Legend 0 Outdoor Temperature Sensor 0 Supply Temperature Sensor/Low Loss Header 0 Boiler Temperature Sensor/High Limit Sensor 3A Boiler Temperature Sensor/High Limit Sensor 0 DHW Temperature Sensor 11 Ionization Electrode 15 Flue Gas temperature Sensor 20 Boiler Pump 21 DHW Pump [211 Pump Output Connection 28 20 Programmable Pump Output* 33 Flow Switch (X2 132HA 80, 88, 100, 285, 311, 352) 35 Gas Valve (X2 B2HA 80, 88, 100, 285, 311, 352) 40 Power Supply ® Accessory Power Output [531 Powered Accessory Connection ® Ignition Transformer ® Powered Accessory Connection ® Fan Motor 100A Fan Motor Control 1 11 Not Used 14 KM -BUS Multi Powered Accessory Connection 156A Switched Output F2 156B Switched Output F1 DE1 Digital Input 1 (Dry Contact) DE2 Digital Input 2 (Dry Contact) DE3 Digital Input 3 (Dry Contact) 0 10 0-10VDC Input 157 Fault Alarm/DHW Recirc. Pump* 190 Gas Modulation Coil 190A Gas Modulation Coil (for 80, 88, 100, 285, 311, 352) * See wiring diagram AO Boiler Control © External Accessory Connection Board © Pump Connection Interface O� Extension Module EA1 © KM -BUS for External Devices © Electrical Junction Box © Field Wiring Connections Al Main Board A2Internal Power Supply Unit A3 Optolink A4 Burner Control Unit A5 Programming Unit A6 Coding Card A7 Connection Adaptor A8 LON Communication Module S1 ON/OFF Switch S2 Reset Button X.. Electrical Interface co 00 00 LO IMPORTANT Electrical installations must comply with the latest edition of: ■ In the U.S.A., the National Electrical Code (NEC), ANSI/NFPA 70 and any other state, local codes and/or regulations. ■ In Canada, the Canadian Electrical Code (CEC), CSA C22.1 Part 1 and any other province, territory, local codes and/or regulations. 47 System Design System Design Considerations IN THE COMMONWEALTH OF MASSACHUSETTS... this product shall be installed by a licensed plumber or gas fitter. the flexible connector (if used) cannot exceed 36". any level type shutoff used must be of tee handle type. Boiler location As a direct vent appliance, the Vitodens 200-W can be installed for room air independent operation (sealed combustion) regardless of size and ventilation method of the room in which it is located. The Vitodens 200-W can be installed, for example, in the main living area of a house, in non -ventilated utility rooms, cupboards, closets and alcoves with no clearance required from combustible materials, as well as in attics with a direct outlet for the flue gas/fresh air system. Follow all local and national codes. Flue gas system PPS (Polypropylene) concentric flue gas/fresh air systems for room air independent operation (sealed combustion) and side wall venting are tested to ANSI Z21 .13 - CSA 4.9 - 2000 standards and are certified together with the Vitodens 200-W boiler as a constructional unit. The Vitodens 200-W boiler may also be vented vertically, using an AL29-4C°special stainless steel, single -wall, room air dependent venting system (UL listed for category IV). For a more detailed description of the direct vent and single -wall vent system, please refer to the Vitodens 200-W Venting System Installation Instructions. Flue gas temperature protection Flue pipes used for the Vitodens 200-W are suitable for max. flue gas temperatures of up to 230°F (110°C). No flue gas temperature protection is required as the maximum permissible flue gas temperature is not exceeded in any operating condition or in the event of malfunctioning. Total permissible hardness of the fill and top -up water Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data Low water cut-off A low water cut-off may be required by local codes. If the boiler is installed above the radiation level, a low water cut-off device of approved type must be installed in all instances. An approved type low water cut-off device must be provided by the heating contractor. Do not install an isolation valve between the boiler and the low water cut-off. Water connections Vitodens 200-W boilers can be used in any fully pumped hot water heating system. Minimum system pressure is 1 bar (14 psig). Chemical corrosion protection products Corrosion does not typically occur in sealed heating systems which have been correctly installed and are correctly operated. Many manufacturers of plastic pipes recommend the use of chemical additives. In this case, only those commercially available corrosion protection products approved for boilers with domestic hot water heating via single -wall heat exchangers (instantaneous plate heat exchangers or DHW tanks) must be used. Water quality Treatment for boiler feed water should be considered in areas of known problems, such as where a high mineral content and hardness exist. In areas where freezing might occur, an antifreeze may be added to the system water to protect the system. Please adhere to the specifications given by the antifreeze manufacturer. Do not use automotive silicate based antifreeze. Please observe that an antifreeze/water mixture may require a backflow preventer within the automatic water feed and influence components such as diaphragm expansion tanks, radiation, etc. Maximum antifreeze content is 50% for the Vitodens 200-W boiler. Do not use antifreeze other than specifically made for hot water heating systems. System also may contain components which might be negatively affected by antifreeze. Check total system frequently when filled with antifreeze. Advise system operator/ultimate owner that system is filled with a glycol mix. The heating contractor must provide a MSDS (Material Safety Data Sheet) for the antifreeze used to the system operator/ultimate owner. Total heating output Specific heating volume <5 USG per 3412 BTU >_ 5USG per 3412 BTU to > 13USG per 3412 BTU < 13USG per 3412 BTU MBH < 170 300 ppm 17.5 gpg 200 ppm 11.7 gpg 2 ppm 0.11 gpg > 170 to < 682 200 ppm 1 1 .7 gpg 150 ppm 8.8 gpg 2 ppm 0.11 gpg > 682 to < 2050 150 ppm 8.8 gpg 2 ppm 0.1 1 gpg 2 ppm 0.11 gpg > 2050 2 ppm 0.1 1 gpg 2 ppm 0.1 1 gpg 2 ppm 0.11 gpg ppm - parts per million gpg - grains per gallon Note: The pH value of the heating water should be between 6.5 and 9.5 48 00 00 LO Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data System Design Considerations (continued) System layout The max. boiler water temperature for space heating and DHW production is 165°F (74°C) for models 19, 68 and 180°F (82°C) for models 26 to 57 and 94 to 199. To minimize distribution losses, Viessmann recommends that the heating and domestic hot water systems be based on a maximum boiler supply temperature of 1580F (700C). Due to the low return temperatures required for gas condensing, no mixing valves should be used in the heating circuit whenever possible. If mixing valves are required, e.g. for multi -circuit systems or underfloor heating systems, only 3-way mixing valves must be used. Do not use 4-way mixing valves with condensing boilers. Underfloor heating systems For underfloor heating systems Viessmann recommends the use of plastic tubing with an oxygen diffusion barrier in order to prevent the diffusion of oxygen through tubing. If plastic tubing without an oxygen diffusion barrier is used in underfloor heating systems, Viessmann recommends that such systems be separated from the boiler with a heat exchanger. Underfloor heating systems and heating circuits containing a very large volume of water must be connected to the boiler via a 3-way mixing valve; please refer to the applicable installation example in this manual. co 00 co Lo System Design Oxygen diffusion barrier underfloor tubing The boiler warranty does not cover leaks resulting from corrosion caused by the use of underfloor plastic tubing without an oxygen diffusion barrier. Such systems must have the non -oxygen diffusion barrier tubing separated from the boiler with a heat exchanger. Viessmann recommends the use of underfloor plastic tubing with an oxygen diffusion barrier. Warranty Our warranty does not cover damages resulting from the following: installation or service by unqualified and unlicensed personnel. attempting to perform any repair work on the boiler other than that mentioned in the boiler literature. tampering with or attempting, without Viessmann permission, to readjust the factory settings of the; -combination gas valve -combustion air opening of the burner blower leaks resulting from corrosion caused by the use of underfloor plastic tubing without an oxygen diffusion barrier. For detailed warranty information, please read warranty sheet supplied with product. 49 Vitodens 200-W, B2HB 19 to 57, 68 to 199 Technical Data 50 Vitodens 200-W, 1321-113 19 to 57, 68 to 199 Technical Data 51 Vitodens 200-W, 1321-113 19 to 57, 68 to 199 Technical Data Quick Reference °C OF -40 -40 -35 -31 -25 -13 -20 -4 -18 0 -16 +3 -14 +7 -12 + 10 -10 + 14 -9 + 16 -8 + 18 -7 + 19 -6 + 21 -5 + 23 -4 + 25 -3 + 27 -2 + 28 -1 + 30 0 + 32 +1 +34 +2 +36 +3 +37 + 4 + 39 +5 +41 +6 +43 +7 +45 +8 +46 +9 +48 +10 +50 +12 +54 +14 +57 +16 +61 + 18 + 64 + 20 + 68 + 25 + 77 + 30 + 86 +35 +95 + 40 + 104 + 50 + 1 22 + 60 + 140 + 70 + 1 58 + 80 + 1 76 + 90 + 194 +100 +212 +110 +230 Viessmann Manufacturing Company Inc. Viessmann Manufacturing Company (U.S.) Inc. 750 McMurray Road 45 Access Road �t Waterloo, Ontario . N2V 2G5 • Canada Warwick, Rhode Island • 02886 • U5A Techlnfo Line 1-888.484.8643 Techlnfo Line 1-888-484-8643 00 1-800-387-7373 • Fax (519) 885-0887 1-800-288-0667 • Fax (401) 732-0590 www.viessmann.ca . info@viessmann.ca wwvw.viessmann-us.com ■ info@viessmann-us.com Wirsbo hePEXTm Tubing - Coils Submittal Information Revision A: Jan. 8, 2010 Project Information Job Name: Location: Part No. Ordered: Engineer: Date Submitted: Contractor: Submitted By: Manufacturer's Representative: Approved By: Technical Data Material: Crosslinked polyethylene PEX-a Engel Method Standard Grade 200°F at 80 psi (93°C at 5.51 bar); 180°F at 100 psi (82°C at 6.89 bar) Hydrostatic Ratings (PPI): 73.4°F at 160 psi (23°C at 11.03 bar) Linear Expansion Rate: 1.1"/10°F per 100 ft. (27.94mm/5.56°C per 30.48m) Product Information and Application Use Wirsbo hePEX­ tubing is used for closed -loop radiant heating applications. It has an oxygen diffusion barrier that meets German DIN 4726. A polyethylene layer is extruded over the oxygen barrier to protect from site abuse and moisture saturation. uponof ✓ Description Part Number I.D. O.D. Weight 5/16" Wirsbo hePEX, 100-ft. coil 5/16" Wirsbo hePEX, 250-ft. coil 5/16" Wirsbo hePEX, 1,000-ft. coil 3/s" Wirsbo hePEX, 100-ft. coil 3/s" Wirsbo hePEX, 400-ft. coil 3/s" Wirsbo hePEX, 1,000-ft. coil 1/2" Wirsbo hePEX, 100-ft. coil 1/2" Wirsbo hePEX, 300-ft. coil 1/2" Wirsbo hePEX, 1000-ft. coil 5/8" Wirsbo hePEX, 100-ft. coil 5/8" Wirsbo hePEX, 300-ft. coil 5/8" Wirsbo hePEX, 1,000-ft. coil 3/4" Wirsbo hePEX, 100-ft. coil 3/4" Wirsbo hePEX, 300-ft. coil 3/4" Wirsbo hePEX, 500-ft. coil 1" Wirsbo hePEX, 100-ft. coil 1" Wirsbo hePEX, 300-ft. coil 1" Wirsbo hePEX, 500-ft. coil 11/4" Wirsbo hePEX, 100-ft. coil 11/4" Wirsbo hePEX, 300-ft. coil 11/2" Wirsbo hePEX, 100-ft. coil 11/2" Wirsbo hePEX, 300-ft. coil 2" Wirsbo hePEX, 100-ft. coil 2" Wirsbo hePEX, 300-ft. coil A1140313 A1180313 A1220313 A1140375 A1210375 A1220375 A1140500 A1250500 A1220500 A1140625 A1250625 A1220625 A1140750 A1250750 A1240750 A1141000 A1251000 A1241000 A1141250 A1251250 A1141500 A1251500 A1142000 A1252000 0.292" 0.292" 0.292" 0.350" 0.350" 0.350" 0.475" 0.475" 0.475" 0.574" 0.574" 0.574" 0.671" 0.671" 0.671" 0.862" 0.862" 0.862" 1.054" 1.054" 1.244" 1.244" 1.629" 1.629" 0.430" 0.430" 0.430" 0.500" 0.500" 0.500" 0.625" 0.625" 0.625" 0.750" 0.750" 0.750" 0.875" 0.875" 0.875" 1.125" 1.125" 1.125" 1.375" 1.375" 1.625" 1.625" 2.125" 2.125" 005.51 lbs. 011.00 lbs. 036.00 lbs. 005.51 lbs. 020.00 lbs. 044.00 lbs. 005.51 lbs 020.00 lbs. 060.00 lbs. 008.37 lbs. 028.00 lbs. 086.00 lbs. 011.24 lbs. 034.00 lbs. 056.00 lbs. 014.10 lbs. 058.00 lbs. 095.00 lbs. 034.00 lbs. 106.00 lbs. 044.00 lbs. 133.00 lbs. 068.20 lbs. 204.06 lbs. Installation Approved fitting systems include ProPEXO and APR.' Refer to the Uponor Radiant Installation Handbook for additional information Standards CSA B137.5; ASTM F876; ASTM F1960; ASTM-E84; CAN/ULC S102.2; ASTM-E119/UL 263 Codes IPC; UPC; NSPC; IRC; NPC of Canada Listings NSF-rfh; ITS; UL; PPI; WARNOCK HERSEY 25 FS/50SD plenum listing Related Applications Contact Information Radiant Heating and Cooling System Uponor, Inc. Uponor Ltd. Snow and Ice Melting System 5925 148th Street West 2000 Argentia Rd., Plaza 1, Ste. 200 Permafrost Protection System Apple Valley, MN 55124 USA Mississauga, ON L5N 1W1 CANADA Turf Conditioning System Phone: (800) 321-4739 Phone: (888) 994-7726 Fax:(952) 891-2008 Fax:(800) 638-9517 www.uponor-usa.com www.uponor.ca 'ProPEX° is a registered trademark of Uponor, Inc. ProPEXT is a trademark of Uponor Ltd. Two -wire Thermal Actuator for Engineered Plastic (EP) Heating Manifold Submittal Information Revision A: May 16, 2011 Project Information Job Name: Location: Part No. Ordered: Engineer: Date Submitted: Contractor: Submitted By: Manufacturer's Representative: Approved By: Technical Data Operating Voltage: Operating Range: Maximum Close -off Pressure Time to Open/Close: Operating Current 24VAC nominal 22V to 28V 17 psi 3 to 5 minutes 0.167A (167mA) Product Information and Application Use The Two -wire Thermal Actuator for EP Heating Manifold is a slow - opening thermal actuator that mounts directly onto the EP Heating Manifold and connects to the Uponor Climate C6ntrolTM Zoning System C-55 Base Unit (A3601012). It provides individual loop flow control on a multi -zoned manifold. ✓ Description ❑ Two -wire Thermal Actuator (for EP Heating Manifold) Installation Part Number Height Width A3030522 2.47" 1.58" uponof Depth Weight 1.58" 0.22lbs. Mount directly onto the EP Heating Manifold. Refer to the Uponor Climate Control Zoning System Installation Guide for additional information. Standards Class II wiring Codes N/A Listings N/A Related Applications Contact Information Radiant Heating and Cooling Systems Uponor, Inc. Uponor Ltd. Snow and Ice Melting Systems 5925 148th Street West 2000 Argentia Road, Plaza 1, Suite 200 Permafrost Protection Systems Apple Valley, MN 55124 USA Mississauga, ON L5N 1W1 CANADA Turf Conditioning Systems Phone: (800) 321-4739 Phone: (888) 994-7726 Fax: (952) 891-2008 Fax: (800) 638-9517 www.uponor-usa.com www.uponor.ca Engineered Plastic (EP) Heating Manifold Assemblies Submittal Information Revision C: May 29, 2013 Project Information Job Name: Location: Part No. Ordered: Engineer: Date Submitted: Contractor: Submitted By: Manufacturer's Representative: Approved By: Technical Data Manifold, Connecting PA66-GF30 Max. Test Pressure 145 psi (10 bar) Piece, Elbow, End Part: (24 h, <_ 86°F) tested with water: Bracket, Locking PA66-GFlS Max. Test Pressure 100 psi (7 bar) Screw: (24 h, <_ 70°F) tested with air: Valve Insert (all plastic Max. Water Flow per 0.97 I/s 15.4 gpm parts), Hand Wheels: POM Manifold: Adjusting Screen: ABS Cv Value Inlet/Outlet 1.4 Valves: Glass Flow Meter PA12 Spring: Stainless Steel Metal Inserts: Brass C38500 O-ring: EPDM Axel: Stainless Steel Flat Gasket: IT-C Adaptable Actuators: EP Heating Manifold, two -wire Actuator (A3030522); Thermal Actuator, four -wire (A3010522) with EP Heating Manifold Actuator Adaptor (A2671300) Maximum Operating 6 bar at 600C 5 bar at 700C Temperature and Pressure: 87 psi at 140OF 72 psi at 158OF 4 bar at 800C 3 bar at 900C 58 psi at 1760F 44 psi at 1940F Product Information and Application Use The Engineered Plastic (EP) Heating Manifold Assemblies feature isolation valves and balancing valves with flow meters, and come fully assembled, ready for installation in hydronic radiant heating and cooling systems. The manifolds are available in 2 through 8 loops, the body ends feature R32 unions and the loop outlets have R20 male threads. The manifold mounts on a bracket (A2670006) that comes with the assembly. Use only propylene glycol in radiant systems with EP Heating Manifolds; never use ethylene glycol. ✓ Description Part Number ❑ EP Heating Manifold Assembly with Flow Meter, 2-loop A2670201 ❑ EP Heating Manifold Assembly with Flow Meter, 3-loop A2670301 ❑ EP Heating Manifold Assembly with Flow Meter, 4-loop A2670401 ❑ EP Heating Manifold Assembly with Flow Meter, 5-loop A2670501 ❑ EP Heating Manifold Assembly with Flow Meter, 6-loop A2670601 ❑ EP Heating Manifold Assembly with Flow Meter, 7-loop A2670701 ❑ EP Heating Manifold Assembly with Flow Meter, 8-loop A2670801 Installation uponof Height Width Depth Weight 14.0" 9.6" 2.7" 3.50 lbs. 14.0" 11.6" 2.7" 4.16 lbs. 14.0" 13.6" 2.7" 4.82 lbs. 14.0" 15.6" 2.7" 5.48 lbs. 14.0" 17.6" 2.7" 6.14 lbs. 14.0" 19.5" 2.7" 6.80 lbs. 14.0" 21.5" 2.7" 7.46lbs. Do not use thread sealant on connections. Carriers present in these compounds can crack the plastic port connections, resulting in leaks and water damage. For additional information, refer to the EP Heating Manifold Instruction Sheet. Note: Use only propylene glycol in radiant heating and cooling systems with EP Heating Manifolds; never use ethylene glycol. Refer to the EP Heating Manifold Installation Guide for a complete chemicals list. Standards/Codes/ Listings N/A Related Applications Contact Information Radiant Heating and Cooling Systems Uponor, Inc. Uponor Ltd. Snow and Ice Melting Systems 5925 148`h Street West 2000 Argentia Road, Plaza 1, Suite 200 Permafrost Protection Systems Apple Valley, MN 55124 USA Mississauga, ON L5N 1W1 CANADA Turf Conditioning Systems Phone: 800.321.4739 Phone: 888.994.7726 Fax:952.891.2008 Fax:800.638.9517 www.uponorpro.com www.uponorpro.com Designer Contact C 552 07/11 Zoning Replaces: New The tekmarNet® Thermostat 552 is a communicating touchscreen thermostat designed for hydronic heating systems. The extra large touchscreen display allows you to easily adjust 7-day programmable schedules and room temperatures to optimize comfort and energy savings. It operates a single zone of heating and has two auxiliary sensor inputs that can be assigned to measure room, floor, or outdoor temperature. An optional floor sensor allows precise heating of radiant floors by controlling the floor temperature and maintaining the desired room air temperature. Alternatively the room air temperature sensor can also be disabled to solely maintain a minimum floor temperature. The 552 can be wired using 2 or 4 wires to connect to tekmarNet® zoning controls, or can be installed as a stand-alone thermostat using 3 wires. Front View Side View Mounting Base 29/32" (23 mm) 9/16" 13/16" (14 mm)- --- --- CL (20 mm) 1-7/8" ................... ... .... F. oNtNoo� a -- S �� 0P So' (47 mm) 2-1/2" Room lit(64 mm) 3/4" 3-1/4„ 4„ 5 I' I (19 mm) (127 mm) (102 mm) (83 mm) OOING AWAY 552 Neat On JIN41 C I R Rh W1 S7 Com S2 MOR❑❑� MODEE CL! 3-1/4" � F 1-1/2" (82 mm) 151 /16 1 (38 mm) (23 mm) Specifications tekmarNet® Thermostat 552 One Stage Heat Literature D552, Q552, U552 Control Microprocessor control. This is not a safety (limit) control Packaged weight 0.8 lb. (350 g) Dimensions 5" H x 3-1/4" W x 15/16" D (127 x 82 x 23 mm) Enclosure White ABS / PC plastic Approvals Meets Class B: ICES & FCC Part 15 Ambient conditions Indoor use only, 32 to 1220F (0 to 500C), RH <_90% non -condensing Power supply 24 V ±10%, 50/60 Hz, 1.8 VA Standby, 56 VA fully loaded, NEC / CEC Class 2 Relay 24 V (ac) 2 A Sensors NTC thermistor, 10 kQ @ 770F (25°C ±0.2°C) 13=3892 —Included None —Optional tekmar type # 070, 072, 073, 076, 077, 078, 079, 084 Warranty Limited 3 Year See D552 for full warrant Energy Saving Features— • Warm Weather Shut Down • Zone Synchronization • Zone Post Purge • Programmable Schedule • Away Scene Key • Auto Heating Cycle Additional Features • tekmarNet® Communication Compatible • Touchscreen • 2 Auxiliary Sensor Inputs • Floor Warming (with 079 slab sensor) • Pulse Width Modulation • Outdoor Temperature Display • Optional Floor Temperature Display • Air Group Member • Backlight • Freeze Protection • Equipment Exercising • Room Temperature Limiting • Radiant Floor Cooling Member SPECIAL REQUIREMENTS This thermostat is designed to be used with a tekmarNet® Wiring Center or Zone Manager for power and communication. It can also be used in stand alone applications. www.tekmarcontrols.com 1 of 2 0 2011 tekmar® C 552 - 07/11 Sample Application Drawing Below is a sample application drawing for this product. This application may include other tekmar products that are required for installation. More sample applications can be found at www.tekmarcontrols.com. Sample Mechanical diagram atekmarNet® Thermostat 552 313 House Control, Wiring Center or Zone Manager Z1 Z3 ---------rZ4Z2 4 Zone Manifold P Sample Electrical diagram Legend P1 = Zone Manifold Pump Z1 = Zone 1 Z2 = Zone 2 Z3 = Zone 3 Z4 = Zone 4 S1 = Optional Slab Sensor O o � S1 tN4 C R Rh W1 $t Co S2 �!N2 tN2 House Control, Wiring Center or Zone Manager O 0 tekmar' tekmar Control Systems Ltd., Canada, tekmar Control Systems, Inc., U.S.A. Head Office: 5100 Silver Star Road, Control Systems Vernon, B.C. Canada V1 B 3K4, 250-545-7749, Fax. 250-545-0650 Web Site: www.tekmarcontrols.com Product design, software and literature are Copyright © 2011 by: All specifications are subject to change without notice. #W tekmar Control Systems Ltd. and tekmar Control Systems, Inc. 2 of 2 Printed in Canada. C552 - 07/11. W PREMIER w MECHANICAL & ELECTRIC 22118 20th Ave. SE Suite 125 Bothell, WA 98021 425-483-3363 1 contact@premierme.net Hamish Anderson Custom Homes, Inc. I Driessen Residence Mechanical Submittal Package 6. Trim a. Shoemaker Supply Grille— LSW b. Shoemaker Supply Grille — AFP c. Shoemaker Return Grille — 905 SHOEMAKER 1,866,940.0696 M A N U F A C T U R I N G sm@shoemakermfg.com NOMINAL +1 15/16 F111 3/8 2 "NOMINAL /8 LSW 1/2 00 STANDARD FRAME NOMINAL NOMINAL NOMINAL - 1/4 NOMINAL - 1/4 LSW 1/2 200 LSW 1/2 200 X FRAME Y FRAME NOMINAL NOMINAL +1 1/4 +1 15/16 1 1 3/8 20° 7 �1/3 - 1/3 1 F 1 1 /8 1— -4-1 /8 g1 — blla 1 /8 NOMINAL- 1/4 o—N -1/4 AL LSW 1/3 200 LSW 1/3 00 Y FRAME STANDARD FRAME LSW Series Linear Bar Sidewall Diffusers and Grilles (Type 4) MODEL: LSW-T4 Standard Features: • Precision aluminum construction for clean styling and efficient air distribution • Extruded aluminum frame with signature line marks • 1 3/8" frame width • Designed for heating or cooling applications and sidewall installation • Countersunk mounting holes for flush appearance with color matching Philips Posi-drive screws • Available in lengths up to 144" in one piece (may vary for shipping and manufacturing considerations) • 1/8" thick core blades run parallel to longest dimension • 1/2" spacing with 0° or 20° deflection; actual spacing between bars is 3/8" • 1/3" spacing with 0° or 20° deflection; actual spacing between bars is 1/4" • Satin Anodized Options: ❑ Recessed screwdriver -operated opposed blade damper —1/2" spacing (OBD) ❑ Lever -operated opposed blade damper —1/3" spacing (OBD ❑ Extruded aluminum adjustable curved blade air deflection grid (Grid) ❑ Screwdriver -operated opposed blade damper with extruded aluminum adjustable curved blade air deflection grid (OBD-Grid) ❑ Gym Grade construction with welded support brackets and frame, and extra center margin supports (HD) ❑ Short Blades: core blades run parallel to shortest dimension ❑ Special Shapes: mitered and custom shapes diffusers (see website for more details) ❑ Butt joints for continuous lengths ❑ Tamper proof screws ❑ Fractional I.D. and O.D. sizes available 'Blade Spacing Options: Frame Widths: ® 1/2" - 0° Deflection ❑ 1/3" - 0° Deflection 111 3/8" Frame (standard) ❑ 1/2" - 20° Deflection ❑ 1/3" - 20° Deflection ❑ 1 1/4" Frame (option X) ❑ 1 " Frame (option Y) Finishes: STANDARD COLORS DESIGNER COLORS ® Soft White ❑ ■ Black ❑ Aluminum Paint ❑ i Driftwood Tan ❑ ■ Bronze ❑ Coffee Tan ❑ Mill Finish ❑ . Storm Gray C Warm White ❑ Satin Anodized ❑ Cement Gray C Glossy White Continued next page. Shoemaker Manufacturing 618 East 1 st Street, Cle Elum, WA Last Revised: 04/23/20 S HOEMAKER MAN UFACTURI N G OBD & Grid Options: LSW Series 1,866,940.0696 Linear Bar Sidewall Diffusers and Grilles (Type 4) sm@shoemakermfg.com MODEL: LSW-T4 TIq, 2 3/8 llf NOMINAL OPTIONAL -1/4 OBD SCREW DRIVER BLADE CONTROL FRAME OPTIONS: Standard Frame 1 3/8 X Frame Y Frame (��.rrrrrrrrrllll.i ��31/2 �-��I OPTIONAL AND ••D NOMINAL '1 15/16 1/4 .� NOMINAL �. - 3/8 NOMINAL + 1 3/4 1 1 /4 .� NOMINAL �1 - 3/8 NOMINAL + 1 1 /4 1 1 /4 I� NOMINAL - 3/8 Additional Information: Project / Location: Driessm ReddenCe Engineer: Architect: Contractor: Premier Mechanical & Electric 1 2 3/f F lJF IIIJIV/-\L kJRIV NOMINAL + 1 15/16 2 1 /2 NOMINAL -1/4 LSW WITH OBD NOMINAL + 1 3/4 2 1 /2 NOMINAL -1/4 WITH OBD NOMINAL + 1 1 /4 2 1 /2 .� NOMINAL �. -1/4 WITH OBD Submittal Notes Ceiling/9deWall %pply 9 zes TBD FM I LSW-SUB Shoemaker Manufacturing 618 East 1 st Street, Cle Elum, WA Last Revised: 04/23/20 Commercial Submittal SHOEMAKER 1,866,940.0696 Aluminum Floor Perimeter Grille M A N U F A C T U R I N G sm@shoemakermfg.com MODEL: AFP NOMINAL + 1 15/16 1 3/8 20° F F1 /2 -lflfI NOMINAL —-1/4 — AFP 200 NOMINAL +1 15/16 r 1 3/8 �'l F 1,2 u u u u u Iry 2 3/8 '�flfl NOMINAL AFP 0° POSITIVE BALANCE SETSCREW 71 NOMINAL- 1/8 AFP SCREWDRIVER DAMPER CONTROL nf,,,,.. ,,, 2 3/8 OMINL lf lo- DUCT�i AFP WELDED BLADES AND EXTRA CENTER MARGIN SUPPORTS WELDED CORNERS NOMINAL-1/8 AFPGG NOMINAL + 1 15/16 �I lo— 1 /2 r�flf NOMINAL 1/4 AFPGG Additional Information: Project / Location: Driessm Reddence Engineer: Architect: Contractor: Premier Mechanical & Bectric Standard Features: • Extruded aluminum frame with signature line marks • Designed for floor application • Reinforced with pressure lock honeycomb construction to withstand heavy foot traffic • Recessed screwdriver operated Opposed Blade Damper • Positive balance set screw to lock position of Opposed Blade Damper • 1/2" spacing with 0° or 20' deflection • 1/8" thick core blades run parallel to longest dimension • Frame width 1-3/8" • Satin Anodized Options: ❑ Gym Grade with welded blades and frame, and extra center margin supports (AFP-GG) ❑ Grille only (AFG) ❑ Core blades run parallel to shortest dimension Finishes: STANDARD COLORS ❑ Soft White ❑ ■ Driftwood Tan NOMINAL+ 1 15/16 LI4� NOMINAL - 3/8 l— NOMINAL DUCT DESIGNER COLORS ❑ 0 Black ❑ ■ Bronze ❑ ■ Storm Gray ❑ ■ Cement Gray AFG 1/8 '7I NOMINALflflfllll 7 la 1 /4 AFG Submittal Notes Floor S%pply Grille 9zes& FinishesTBD ❑ Aluminum Paint ❑ Coffee Tan ❑ Warm White n ❑ Glossy White AFP-Sub Shoemaker Manufacturing 618 East 1 st Street, Cle Elum, WA Last Revised: 03/27/20 Commercial Submittal SHOEMAKER 1.866,940,0696 Aluminum Airfoil Blade Grille with 450 Fixed Blades M A N U F A C T U R I N G sm@shoemakermfg.com (blades parallel to longest dimension) MODEL: 905 NOMINAL+ 1 15/16 7BLADES FIXED AT 45° 1 /2 r— .666 NOMINAL-1/2 905 Standard Features: • Surface mount fixed blade grille with airfoil blades at 45° • Blades are parallel to longest dimension • Blades are spaced at 2/3" • Extruded aluminum surface mount frame with signature line marks • Countersunk mounting holes for flush appearance with color matching Phillips posi-drive screws • Rust resistant pre -coat with durable powder finish • Soft White Options: ❑ Recessed screwdriver operated Opposed Blade Damper (905-0) ❑ 2" ADC compliant round collar with bead for ease of installation (square sizes only) ❑ Heavy Duty Construction ❑ MRI Compatible ❑ Insect Screen ❑ Fractional, exact I.D. and O.D. sizes ❑ T-20 Tamper Proof Screws 3/4 � � NOMINAL+ 1 15/16 — - — - — - Finishes' STANDARD COLORS Soft White 4 NOMINAL - 3/16 ❑ ■ Driftwood Tan ❑ Mill Finish 905 NOMINAL+ 1 15/16 BLADES FIXED AT 45° —01 � .666 7 4404404 [g1 f 1 [ri "" 13/4 J E J E J 7NOMINAL - 3/16 NOMINAL DUCT 905-0 NOMINAL+ 1 15/16 2 7 NOMINAL - 3/16 NOMINAL DUCT �I 905-0 Additional Information: DESIGNER COLORS ❑ ■ Black ❑ ■ Bronze ❑ ■ Storm Gray ❑ _ Cement Gray ❑ _ Satin Anodized Submittal Notes Project/Location: Driessen Residence Floor %pplyGrille Mir Engineer: Architect:r 9zes& FinishesTBD Contractor: Premier Mechanical & Electric 905-sub Shoemaker Manufacturing 618 East 1 st Street, Cle Elum, WA Last Revised: 03/24/20 ❑ Aluminum Paint ❑ I Coffee Tan ❑ L Warm White ❑ ❑ Glossy White