Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
APPROVED BLD-BLD2021-0049+Mechanical_Plan+1.13.2021_1.59.01_PM+1988355
Downspout @ lower roof — — J1 L— Downspout @ lower roof -01 --——— — — — ——� — — — Downspout @I lower roof IN I Patio conc, slab edge Living Room Patio Downspout @lower roof � Hose bib I ' I -------,���_--- I---- 8 — I- - — I I Center coffer on Living Rm opening I � Living Room 31 Ce'li%coffer line I Hose bib gwnspout @lower roof --\ f- P, Gas fireplace Delete patio screen wall 7'-8 3/4" 7-8 3/4" APPROVED PLANS MUST BE ON JOB SITE City of Edmonds Building Department APPROVED Plans ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES X 2 8 Family Room Patio 12 ' 91-211 Downspout @ tipper and bedroom roof Hose bib Downspout @ upper roof --�\ , >wa t O 1 I O'_ BBQ PrBBQ ' DN w/ hood fan00 - 900 cfm — Range Hood fan 600 - 900 cfm y a Ilh Ceiling coffer line A 1 _N r-- r — —� Refrt I D _WTI I I Cent r, 1 � ��- ill rl o P Mic owcl e !I L , 'I --—I 'inkJ_ ( — I - S',81 /?" enter co ers on Dining Rm windows Din 'ri Room Delete wall/close �. 1bT Ceilil g coffer lime rLlj;� '_'" `" e — Mech. I©" ,;0, fA-i :f, e a 0 _104L Downspout @ lower roof ................................................ Install per manufacturers specifications. Have all manufacturer documentation on site. City Of Edmonds Building Department Work MECHN ICAL Address 9229 OLYMPIC VIEW DR --------------------------------------------------------------------------- Owner DRIESSEN Approved Date 1/21/21 Building Official -------------------- Permit Number BLD2021-0049 — I M 3' 6, je jA I I I I I_ Intl I KITCHEN RANGE HOODS ARE ■ REQUIRED IN ALL DOMESTIC I KITCHENS. HOODS CAPABLE OF EXHAUSTING MORE THAN 400 CFM REQUIRE MAKE UP AIR. IRC M1503 Downspout @ lower roof -� �o, _ \ _ •_ ° I t k I Boiler and air handler equip. 3 Family R !I ' Manuf. - Uiessmann y fl I I` i �� I Model - Uitodens 200 w - B2HB 1, I - o ;.rK<<J -'' Efficiency 95% n }, Sig Ceiling coffer line �an 150 c _ v , Model M A 7t 0 c Yy �` I Capacity - 600-900 CFM exhaust hood M ���' �„ C � ter doors on hall I I (D" 1A #Cv" Control - Interlocked with kitchen hood fa l tr'1��2 0 �+ I � Sink �r 7� I c,c,�Yt s ace access) Mechanical nt _)_ 2'8°x�'0'Pkt. W t, W�? Downspout @lower roof 011 rl- ---3' I� �r .I J - I --- ------ �;--------- 1- I- — ,,!` I n 8 St �r r ii tt rn o t ea _ _ _ _ 11�� I? — — — — — — — rq _ I Hose bib 2'-8" x T_0 I 2 g+ x_ opg, 1 (cased opng) Hall _. 4 f!/� 4' 8" r� ' 4UL �ZA�cgrrdoors}�— Center�l}'���I 7 �jyy�j 6 stud wall _ _ to__ 2'-8" z Mud— t 1 hr door, self closing u r y val �r cas d opng) (cased P ) I j- 2 " 2'-7° Center door on window ";,, ` , hi wall �� � Fctn-1 SO Of," 1 2? _ t _ Fan-80 cfa K ' Powder- FriR ot o No in cree ;, i.-wall �Ce terline IDownspout @ try lower roof 1 I I •I _ I M I 0o -tomes l 1 0- Downspout @ lower roof 4 3 1/2 till- No rainscreen this wall Gasrbage can alcove Downspout @ lower roof 1 Downspout @ lower roof Downspout @ entry lower roof Hose Package alcove - Slope/warp slab away from walls towards opening No rainscreen this wall ]Vlain Floor Plan 1/4" = P-0" Living area - 1,840.8 Sf Garage area = 734.5 Sf Patio area = 1,116 sf Front Porch area = 98 Sf ° I-- — — og wash basin (Use 5/8x GPVB in garage and shop, typ.) --ti.arage (Use 5/8x GWB in garage and shop, typ.) 1 � t 2'-8" — — _k�--Downspout @ lower roof I � I L--� Downspout @ Zx6stud Downspout @ 1 • 2 1/2" Har lie trim '-51/2" 5'-51/2" 7'-1/2" Note! Prescriptive Engergy Code Compliance Refer to form 406.2 that is attached to the permit documents Refer to the window/door schedule for glazing U values ' All faucets shall comply to item 5a on form 406.2 Refer to the following for manufacture equipment model names and numbers. RECEIVED Jan 13 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT cn 00 U �Q 45 m�M ® H ® L -Ar -r JLd W -vn upper I'l U4"% Ov F ut 114" = 1'-0" Living area = 1,261.70 sf Deck area =180 sf o U w w o _ " z 0 V LU QC 3 LL o w a Mhy� Lo M 00 cn 'AA v N m ��00 �Q M3M U N � O 0 H 0x RECEIVED Jan 13 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT h- Patio conc..slab edge Approved A resu .b.1 fire sprinkler system Is requuvd Ar mmended Onwthraughdesign will meet sj-.f.atx n1 and iedace equipment and cnntinnmg ..We- req-ements ECDC19.05.01DR2. Provide a min -um mm2t,an water vrvrse of one mch 1 t-) meter and one and one hall I1]/2') seine hno nr show that domestc and fire protZ. needs can he met w,th a smeller service V Akd�(""r I I I I Uownsponl � �r roaf� � I I I I I ! I I I I I 11 I I I I I I Hose bib\ — Dm.nrt••w�lbwrrroa/--�y I -� L - - - - 12' - Patio screen wad 'za(IeS Living Room Patio - - I I I I I I I I I L4 do g : LivinRoom Y, I I l 1 //-C'cllir{q coffer line + is-srn^ - 8 16' --------- - �— - _ n' — -- --- --- Ig' - '' 5`6— 3'. upper and bwnspaut 0bedroan roof - - - I Family Room 9'- I Patio - Downspod C4 upper roof Han bib BBQ P daSaa rJn -- --- -- -_ T I , < <er h i I - Dow - low roof Ji Boiler andair regdp.CelocroViessnaanMaafFamily •r �r I IT I •� - I� __II I f y2w R2H/ E(cienry-95% Ceiling crpiIte 1SOcfia }' cook to make ttp I S Moder.d3uA57S0a a __1 Center spoors on hill 9 Capac[ty6OO-ADO hMeshaust hood IPe I t'-ro•srn' Sink } �. con troI-INerla with kitchen hood eZ Srn'k i . I ¢ICal P• —_ _ n�rrresrs•rr,.r .a, -v vrr NiC11Ali_ -� •� Dawrrspa Iowa Laundry' f 4 1_t _I_:` I •. .e-��'1 aw•.rn• I 1�11osebib �..., r•. ra t Hall _ r yI -eL4rt �� Align" -r9 Centerline �•a, - `" `r"+ - - I s� foT- -2'3•i r-0%__ _ b.. 1hr Anor, ulfclaslag,�/ I Center dPN an wiadnw mail. pwaf Mud Entryr Fan'150 cfm I � I Dtn Rooakt � � � �,f try vas w _ _ CJ LWkI - 's lUse 518yOWB _ ; - Doi. ryaW a tower roof Powder J i•�•, Td• C ra garage and L"30P- �- Ceiling, coffer line No ip4escrecn this) - - blecA chose-r Hose bib lower roof /Al 4&1 �` Q C- No rainureen this L� \ Garbage can `. Downspaal®bw ,mot Downspout a rawer roof Downspout ® entry Orwer roof Hose Package alcove - Sfoprlwrop sbb away from wills whnrtis olkuing No raintereen IN$ wall N Main Floor Plan 114'= I'-0' Living area=1,840.8 sf Garage area = 734.5 sf Patio area = 1,116 sf Front Porch area = 98 sf Dawnspout 0 lower roof F- M Downspout 01 I I I I I I I I image I r� usesia�cwe i ingarage and I sMP•+1ri•1 � I Dawnspow 0 __ - - - 9' — 1' 25'- - P ro{t? '!'rya �C^ `�1 4 z 1 z -V- - f 1r t Nose! Prescriptive EngerMv Code Compliance _ Refer mfornt 4062 that is adaehed to the pent it ' documents Refer to the mudow:daormhedak forSlating U saluas AlI faunal. Ad/ comply to Item So -fam 4062 1 - P,ft, I.thefollarngf- maoufreurre e9.,P.-fmt�od.1 -r `�atdmrmbr.^ � 2�rfrLd � .B�zal4- t3Zi Q � O a a N a U W . cut ti O �a of 2 RESUS FEB 14 !02° t.,t�1:•r. , a . � r �r.� y 4- di c, r'l j 27: u (.,t e' i Downspour (& bedmmn i oof-- Dnwnspnm F9 bedroom roofer J Hash bib 6 deck IS I I I 1 I t I I I I Deck I I I � I I I I L Downspola @ Ndroom roof - I I Y ~L _-_- Downspout ® upper roof Downspanr � bedmaxt roof 59' N Upper Floor Plan 114' = r-0" Living area = 1,261.70 sf Deck area = 180 sf Downspout 0 bedroom roof != I j� I I � I i I I ! I I i �� !t'vw,�nm � bedrorurr myf I J I I I I I I Garage roof O Q� Q N A Q Q N a r , V ao N a O 3 RESUB FEB 15 2020 PAMIA40 clr'nl era PANEL LAYOUT FOR THIS SECTION STARTS HERE FIRST FLOOR PANEL LAYOUT FIRST FLOOR TUBE LAYOUT VI 1!l1\L LJ 1 Pl1 VLL - 1..7 VI IPl1\L Li 1 Pl1 VLL - L1 Scale: 1/4"=1'-0" Scale: 1 /4"=1'-0" PANEL SCHEDULE TYPE QUANTITY COMMENTS S 34 J) L 8 O R 8 0 9 00 F 4 4) ANY PANELS IN THE DRAWING THAT ARE MARKED WITH AN 1 ASTERISK (*) INDICATE A PANEL THAT IS TO BE TRIMMED. A CAREFUL MEASUREMENT SHOULD BE MADE TO GUARANTEE A CORRECT INSTALLATION. DOUBLE PANELS WILL CONSIST OF A "HALF DOUBLE -LEFT' PANEL AND A "HALF DOUBLE -RIGHT" PANEL. ON THE OPANEL LAYOUT, YOU MAY SEE A PANEL MARKED AS "HD-L" OR "HD-R." THIS MEANS THAT YOU CUT ONE OF THESE DOUBLE PANELS IN HALF AND USE THE APPROPRIATE SIDE AS MARKED FOR THE INSTALLATION. TONGUE AND GROOVE PLYWOOD OCONVENTIONAL PANELS USED TO FILL IN EMPTY SPACES WHERE WARMBOARD MAY NOT BE APPROPRIATE. NOTE: TUBING IS REQUIRED TO BE INSTALLED AFTER WALLS ARE FRAMED ESTIMATED CUSTOM ROUTES TURNS 90 TOTAL LINEAR LENGTH OF STRAIGHT ROUTES 391 LOOP SCHEDULE ZONE MANIFOLD LOOP LENGTH 1 1 1 220' 1 1 2 205' 2 1 3 215' 2 1 4 205' 2 1 5 195' 3 2 1 255' 3 2 2 260' 4 2 3 135' 4 2 4 265' 4 2 5 95' Total 2050'-0" MANDATORY STRUCTURAL NOTES 1. TO ENSURE OPTIMAL PANEL INSTALLATION, FOLLOW PANEL LAYOUT PLANS, ALL WARMRBOARD INSTALLATION INSTRUCTIONS, AND APA GUIDELINES. FAILURE TO DO SO COULD CAUSE PANEL WASTE. 2. WARMBOARD PLANS ARE CONCEPTUAL AND DO NOT SUPERSEDE STRUCTURAL PLANS WHICH MAY BE PART OF THE ARCHITECTURAL PLAN SET. SHOULD THERE BE A CONFLICT BETWEEN WARMBOARD PLANS AND THE STRUCTURAL PLANS, CONSULT IMMEDIATELY WITH WARMBOARD CUSTOMER SERVICE BEFORE PROCEEDING. 3. INSTALLING CONTRACTOR IS RESPONSIBLE TO VERIFYING ALL MEASUREMENTS PRIOR TO THE INSTALLATION OF WARMBOARD PANELS. QUESTIONS? FOR IMMEDIATE ASSISTANCE CALL: 877-338-5493 (8AM - 5PM PT) WARMBOARD LEGEND S STRAIGHT PANEL LEFT TURN PANEL RIGHT TURN PANEL D DOUBLE TURN PANEL HRD- HALF DOUBLE PANEL -RIGHT TURN HD- HALF DOUBLE PANEL -LEFT TURN L F FILLER PANEL ASTERISK DENOTES A TRIMMED PANEL. JOIST TUBING CUSTOM GROOVE BURIED TUBING BURIED POINT MANIFOLD LOOP SUPPLY � RETURN MANIFOLD ZONES i ZONE 1 250' LENGTH ZONE Z. #,# m 2 PORTS IMPORTANT NOTE: INSULATION BELOW WARMBOARD IS MANDATORY FOR PROPER PERFORMANCE. MANDATORY TUBING NOTES 1. USE ONLY WARMBOARD APPROVED TUBING. SEE INSTALLATION MANUAL 2. USE AN APPROPRIATELY WEIGHTED ROLLER TO PRESS TUBING INTO CHANNELS. 3. MINOR FIELD MODIFICATION OF TUBING PLAN IS WELCOME AND TYPICAL. WHEN IN DOUBT CALL WARMBOARD CUSTOMER SERVICE. QUESTIONS? FOR IMMEDIATE ASSISTANCE CALL: 877-338-5493 (8AM - 5PM PT) , REVISIONS: BY: 0 U u Zcc 0 CL ., Q r 00 LLI � Q u1i ''^� LL � J v) 0? _ W O p X o �0 0 J LLI-r Lo Cr C� L0 Q U C w C,2 O �� Or.- Q LJ o 00 a� Q >� 0 E W U z W O Q (n o Lu rl- T-rl-cn Lo Z * Z O 2i W o /) �,/U LU ) W O W m � 1 O J � W Q Z J Q DATE: 07/24/2020 SCALE: 1/4" = 1' DRAWN: R. Seitchick REVIEWED: TW SHEET: 1 OF 3 SECOND FLOOR PANEL LAYOUT Scale: 1 /4"=1'-0" CUSTOM GROOVE MAY BE A MINIMUM OF 6" FROIV CUSTOM GROOVE RED J SECOND FLOOR TUBE LAYOUT Scale: 1/4"=1'-0" PANEL SCHEDULE TYPE QUANTITY COMMENTS s 12 O L 12 J) R 10 0 9 00 F 0 4) ANY PANELS IN THE DRAWING THAT ARE MARKED WITH AN 1 ASTERISK (*) INDICATE A PANEL THAT IS TO BE TRIMMED. A CAREFUL MEASUREMENT SHOULD BE MADE TO GUARANTEE A CORRECT INSTALLATION. DOUBLE PANELS WILL CONSIST OF A "HALF DOUBLE -LEFT' PANEL AND A "HALF DOUBLE -RIGHT" PANEL. ON THE OPANEL LAYOUT, YOU MAY SEE A PANEL MARKED AS "HD-L" OR "HD-R." THIS MEANS THAT YOU CUT ONE OF THESE DOUBLE PANELS IN HALF AND USE THE APPROPRIATE SIDE AS MARKED FOR THE INSTALLATION. TONGUE AND GROOVE PLYWOOD OCONVENTIONAL PANELS USED TO FILL IN EMPTY SPACES WHERE WARMBOARD MAY NOT BE APPROPRIATE. PANEL LAYOUT FOR THIS SECTION STARTS HERE NOTE: TUBING IS REQUIRED TO BE INSTALLED AFTER WALLS ARE FRAMED ESTIMATED CUSTOM ROUTES TURNS 65 TOTAL LINEAR LENGTH OF STRAIGHT ROUTES 191 LOOP SCHEDULE ZONE MANIFOLD LOOP LENGTH 5 3 1 280' 5 3 2 155' 5 3 3 105' 6 3 4 190' 7 4 1 225' 7 4 2 105' 7 4 3 140' 8 4 4 225' Total 1425'-0" MANDATORY STRUCTURAL NOTES 1. TO ENSURE OPTIMAL PANEL INSTALLATION, FOLLOW PANEL LAYOUT PLANS, ALL WARMRBOARD INSTALLATION INSTRUCTIONS, AND APA GUIDELINES. FAILURE TO DO SO COULD CAUSE PANEL WASTE. 2. WARMBOARD PLANS ARE CONCEPTUAL AND DO NOT SUPERSEDE STRUCTURAL PLANS WHICH MAY BE PART OF THE ARCHITECTURAL PLAN SET. SHOULD THERE BE A CONFLICT BETWEEN WARMBOARD PLANS AND THE STRUCTURAL PLANS, CONSULT IMMEDIATELY WITH WARMBOARD CUSTOMER SERVICE BEFORE PROCEEDING. 3. INSTALLING CONTRACTOR IS RESPONSIBLE TO VERIFYING ALL MEASUREMENTS PRIOR TO THE INSTALLATION OF WARMBOARD PANELS. QUESTIONS? FOR IMMEDIATE ASSISTANCE CALL: 877-338-5493 (8AM - 5PM PT) WARMBOARD LEGEND S STRAIGHT PANEL LEFT TURN PANEL RIGHT TURN PANEL D DOUBLE TURN PANEL HRD- HALF DOUBLE PANEL -RIGHT TURN HD- HALF DOUBLE PANEL -LEFT TURN L F FILLER PANEL ASTERISK DENOTES A TRIMMED PANEL. JOIST TUBING CUSTOM GROOVE BURIED TUBING BURIED POINT MANIFOLD LOOP SUPPLY � RETURN MANIFOLD ZONES i ZONE 1 250' LENGTH ZONE Z:#,# 2 PORTS IMPORTANT NOTE: INSULATION BELOW WARMBOARD IS MANDATORY FOR PROPER PERFORMANCE. MANDATORY TUBING NOTES 1. USE ONLY WARMBOARD APPROVED TUBING. SEE INSTALLATION MANUAL 2. USE AN APPROPRIATELY WEIGHTED ROLLER TO PRESS TUBING INTO CHANNELS. 3. MINOR FIELD MODIFICATION OF TUBING PLAN IS WELCOME AND TYPICAL. WHEN IN DOUBT CALL WARMBOARD CUSTOMER SERVICE. QUESTIONS? FOR IMMEDIATE ASSISTANCE CALL: 877-338-5493 (8AM - 5PM PT) , REVISIONS: BY: 0 U u Zcc 0 CL ., Q r 00 LLI � Q u1i ''^� LL � J v) 0? _ W O p X o �0 0 J LLI-r Lo Cr C� L0 Q C U w �2 O �� Or.- Q LJ o 00 a3: Q >�: 0 E W U Z W O Q (n o Lu rl- T—rl-cr; Ln 0 Z * Z O 2i W C) /) �,/U LU ) W O W m � 1 O J � W Q Z J Q DATE: 07/24/2020 SCALE: 1/4" = 1' DRAWN: R. Seitchick REVIEWED: TW SHEET: 2OF3 THIS WARMBOARD DESIGN CONSISTS OF: SPECIFYING PANELS, TUBING, AND MANIFOLDS ONLY. WARMBOARD SHOP DRAWINGS DO NOT INCLUDE THE FOLLOWING: ROOM BY ROOM HEAT LOSS CALCULATIONS, PROPER DESIGN OF FLOW RATES, REQUIRED WATER TEMPERATURES, SIZING OF CIRCULATION PUMPS, SIZING OF DISTRIBUTION LINES, SIZING OF OTHER COMPONENTS NECESSARY FOR PROPER HYDRONIC SYSTEM OPERATION, SPECIFICATION OF HEAT SOURCE, OR COMPLETE ELECTRONIC CONTROL STRATEGY. SUCH DESIGN SERVICES RELATED TO THESE COMPONENTS OF A HYDRONIC SYSTEM ARE TYPICALLY PERFORMED BY THOSE RESPONSIBLE FOR SUPPLYING AND/OR INSTALLING THESE COMPONENTS. WARMBOARD INC. HIGHLY RECOMMENDS CONSULTING WITH A QUALIFIED RADIANT DESIGNER, MECHANICAL ENGINEER OR MECHANICAL CONTRACTOR FOR COMPLETE INTEGRATED SYSTEM DESIGN THAT MEETS OR EXCEEDS RPA GUIDELINES. DESIGN PROFESSIONALS SHALL RELY ON WARMBOARD TUBING LAYOUTS AND OUTPUT TABLES FOR THEIR DESIGN CALCULATIONS. WHEN IN DOUBT, ASK! Please review all installation instructions. If there are any questions or need for technical assistance call:1 877 338-5493 QTY MANIFOLD & TUBING MATERIALS LIST DESCRIPTION 3 1 000'X 1 /2" AL PEX ROLL NOTES (1.1,1.2,1.3,1.4,2.3) 980' (1.5,2.1,2.2,2.4) 975' inch 4 n n n n n n Any `L.J,J. I ,J.L,J.J,J.`t,`t.L) 930' 1 500' X 1 /2" AL PEX ROLL (4.1,4.3) 365' 1 300' X 1 /2" AL PEX ROLL (4.4) 225' SINGLE SUPPLY & RETURN 2 PORT SUPPLY & RETURN MANIFOLD KIT 3 PORT SUPPLY & RETURN MANIFOLD KIT 2 4 PORT SUPPLY & RETURN MANIFOLD KIT MULTI ZONE EA. 2 5 PORT SUPPLY & RETURN MANIFOLD KIT MULTI ZONE EA. 6 PORT SUPPLY & RETURN MANIFOLD KIT 7 PORT SUPPLY & RETURN MANIFOLD KIT 8 PORT SUPPLY & RETURN MANIFOLD KIT 9 PORT SUPPLY & RETURN MANIFOLD KIT 10 PORT SUPPLY & RETURN MANIFOLD KIT 36 1/2" COMPRESSION FITTINGS 18 24 VOLT ACTUATORS WARMBOARD MANIFOLD LAYOUT MANIFOLD INSTALLATION (WARMBOARD PANELS) - WITH ACTUATORS SCALE: NONE IIIIIIIIi•I COPPI (CON SUPPLY OR COPF WARMBOARD PANEL INSULATED (MIN R-4) SUPPLY AND RETURN PIPING TO MANIFOLD HEADER �T GLASS/FLOW METER TYP. 'PY MANIFOLD SE BIB TYP. -UATOR TYP. FOMATIC AIR VENT TYP. -URN MANIFOLD /IPRESSION FITTING PEX TUBING BLOCKING 14-Y2' 10"MIF SIDE VIEW WALL GOODS (DRYWALL, ETC.) 2x6 WALL STUD OR FUR OUT ALL (MIN 5-1/2" WALL REQ.) LYWOOD BACKING )LD BRACKET, SECURE 'WOOD BACKING S PANEL PER 'ECT WARMBOARD PANEL FRAMING DIMENSIONS FOR MANIFOLD BOX LOOPS W X H 2 14"X36" CLEAR 3 16"X36" CLEAR 4 18"X36" CLEAR 5 1 20X36 CLEAR 6 22"X36" CLEAR 7 24"X36" CLEAR 8 26"X36" CLEAR MANIFOLD INSTALLATION (WARMBOARD PANELS) - NO ACTUATORS SCALE: NONE SHUTOFF VALVE TEMPERATURE GUAGE COPPER TO PEX UNION (COMPRESSION TYPE) SUPPLY AND RETURN PEX OR COPPER TUBING TRIMMER ZONE VALVE OR ZONE - PUMP (MAY BE PLACED IN MECHANICAL ROOM) SILL PLATE WARMBOARD PANEL INSULATED (MIN R-4) SUPPLY AND RETURN PIPING TO MANIFOLD STUD BAY STUD BAY JOIST SPACE ,W, WALL STUD 2x HEADER SIGHT GLASS/FLOW METER TYP. SUPPY MANIFOLD HOSE BIB TYP. SHUT-OFF VALVE TYP. AUTOMATIC AIR VENT TYP. COMPRESSION FITTING 1 /2" PEX TUBING BLOCKING 14-/2' 10"MIF SIDE VIEW WALL GOODS (DRYWALL, ETC.) 2x6 WALL STUD OR FUR OUT ALL (MIN 5-1/2" WALL REQ.) 'LYWOOD BACKING )LD BRACKET, SECURE 'WOOD BACKING S PANEL PER -ECT WARMBOARD PANEL FRAMING DIMENSIONS FOR MANIFOLD BOX LOOPS W X H 2 14"X36" CLEAR 3 16"X36" CLEAR 4 18"X36" CLEAR 5 20"X36" CLEAR 6 22"X36" CLEAR 7 24"X36" CLEAR 8 26"X36" CLEAR REVISIONS: BY: 0 U U Q z ° m - Q 3: 1Q 00 � W CY)< 6 -1 "0 0- coJ < U)002E "w 0 0 X O �O O U J W M �� �o � O U cz,)m ��r` a Lo 0 3: O 3:9� w W 00 Q >3: 0 W U z W 0 — Q �3: W co ry L p Z z m O O 2 W C) w W W W L.L 0 J 0 LL � z � Q O C-6 >- z J m DATE: 07/24/2020 SCALE: NTS = 1' DRAWN: R. Seitchick REVIEWED: TW SHEET: 3OF3 EX AL PEX TUBING JISHED FLOOR *8" WARMBOARD TANGENTIAL GROOVE (1/2" groove typ. ) INSULATION FLOOR JOISTS WARMBOARD OVER JOIST/TJI I WARMBOARD %2" PEX AL PEX TUBING WARMBOARD RIGID FOAM INSULATION Scale: N/S 2"x4" PRESSURE TREATED SLEEPER @ 16" o.c. OR 24" o.c. 6 mil POLYETHYLENE VAPOR BARRIER CONCRETE SLAB • ,ed. d° P:TP: e: TONGUE 3nooao TONGUE TONGUE 3nooao TONGUE > ONGUE 3nooao 3nooao TONGUE �_ J 3 Oao TONGUE o� 3nooao TONGUE 3nooao LEFT TURN PANEL � RIGHT TURN PANEL S STRAIGHT PANEL D DOUBLE TURN PANEL HD- *HALF DOUBLE PANEL -LEFT TURN L (Cut a Double panel in half to get this piece) HD- *HALF DOUBLE PANEL -RIGHT TURN R (Cut a Double panel in half to get this piece) TONGUE LL 3nooao F FILLER PANEL HF HALF FILLER PANEL PEX AL PEX TUBING NISHED FLOOR %" WARMBOARD TANGENTIAL GROOVE (1/2" groove typ.) INSULATION FLOOR JOISTS CIVJ 1 llv,3 DuorLOOR EXISTING SUBFL Scale: N/S TUBING IN GROOVE DRILL BURY POINT HOLE AT A 300 ANGLE WITH 11/16" DRILL BIT * DEBUR ALL EDGES AROUND BURY POINTS AND SAND AS NECESSARY TO PROVIDE SMOOTH TRANSITION TOP OF WARMBOARD WARMBOARD INSTALLATION NOTES - MANDATORY: The contractor(s) responsible for the installation of the Warmboard panels, as well as any hydronic tubing supplied by other, shall review these plans for accuracy and completeness. These contractors will also be responsible to verify all measurements prior to any Warmboard installations. Any discrepancy between these plans an the framing of the project for which they apply shall be brought to the immediate attention of Warmboard, Inc. WHEN IN DOUBT, ASK! -,,300 Please review all installation instructions. If there are any questions or need for technical assistance call: 1 877-338-5493 TO ORDER PRODUCT PLEASE CALL: 1-877-338-5493 %2" PEX AL PEX TUBING 6 mil POLYETHYLENE VAPOR BARRIER INSULATE SUPPLY AND RETURN 1%$" WARMBOARD LEADERS BELOW SUBFLOOR IN UNCONDITIONED SPACE, MIN. R-4 JOIST BURY POINT DETAIL -- SCALE: NONE a< CONCRETE SLAB a. 'a 6-P . e WARMBOARD CONCRETE SLAB Scale: N/S A.1- WARMBOARD PANEL DETAIL SCALE: NONE WARMBOARD SPECIFICATIONS A. GENERAL INFORMATION 1. Warmboard Radiant Subfloor is manufactured in the USA, and supplied by: Warmboard Inc. 8035 Soquel Drive, Ste 41A Aptos CA 95003 877-338-5493 2. Warmboard panels shall be 4'x8' plywood, tongue and groove, with a thickness of 1-1/8". Panels shall have 5/8" depth channels, consisting of straights and turns patterns, such channels on 12" centers to interface with 1/2" PEX aluminum PEX tubing. 4 Limber slots per panel, 2 limber slots cut on the bottom of the 4' end. Limber slots located 12" from the outside. Each slot is 5,,x3/8"x 3/8" The entire top skin (4'x8') of plywood shall have a highly conductive continuous sheet of 1100 series aluminum alloy, bonded to the entire surface. The continuous sheet of aluminum shall completely contour in all channels depths: both turns and straight runs. Panels shall be (4'x8') in one of the four tubing channel pattern options. - Straight, Double, Turns (turns at one end), Left or Right - (See Detail A. 1). 3.All panels installed will meet or exceed all specifications documented on Warmboard engineered AutoCAD drawings and Warmboard Installation manual. Supplied panels will meet or exceed APA certification and report #T2002Q-37 Supplied panels will meet or exceed ICC Evaluation ESR# 1421 and CSA0325 (Canadian Standards Association). 4. Panel assembly shall be one of the following: Warmboard structural subfloor installed over existing Joist or TJI. (See Detail B) Warmboard structural subfloor installed over existing concrete slab (See Detail C) Warmboard structural subfloor installed over existing concrete slab with sleepers (See Detail D) Warmboard Structural subfloor installed over existing structural plywood, decking or OSB. (See Detail E) 1-1/8" 8' A. GENERAL INFORMATION 1. WARMBOARD IS ONE COMPONENT OF A HYDRONIC SYSTEM. THIS CONCEPTUAL PLAN COVERS ONLY PANEL AND TUBING LAYOUTS AND DOES NOT CONSTITUTE A COMPLETE INSTALLATION GUIDE FOR A HYDRONIC SYSTEM. Installation of a hydronic system employing Warmboard-R panels requires a combination of carpentry and plumbing skills. The general contractor shall be responsible for the skills, training, and experience of the installers. Warmboard refers to floor framing information supplied by the customer. Deviations should be brought to the immediate attention of Warmboard, Inc. The hydronic contractor shall follow the tubing layout plan and tubing installation instructions supplied. They shall also be responsible for providing an accurate heat loss analysis and the installation of the hydronic system as a whole in accordance with Radiant Panel Association (RPA) guidelines. Design floor and supply water temperatures for a given floor covering will follow RPA guidelines and the Warmboard recommended water temperatures chart. 2. It is the installer's responsibility to assure the system functions properly, safely, and meets all local, state, and regional codes. 3.The installer is to supply and install all materials shown on this plan; as well as all other materials needed to complete this hydronic system and any incidental work not shown or specified, which can be reasonably inferred as belonging to the work necessary to provide the complete system. 4. Warmboard makes no guarantee for any material to be installed in this hydronic system other than the Warmboard panels. B. WARMBOARD INSTALLATION 1. WARMBOARD shall verify the compatibility of their layout with the attached floor framing plan. Special attention shall be given to the compatibility of Warmboard panels and joist layout. 2. All supply and return tubing below subfloor in unconditioned space shall be insulated with R-4.0 pipe insulation. 3.Custom grooves shall be routed as indicated on the plans using supplied router templates, a properly sized router equipped with a template guide, and the supplied 5/8" core box router bit. All router use shall conform to supplied instructions, and all safety instructions provided by manufacturer of the router you plan to use. 4. When applicable, installation contractor shall coordinate with the plumbing contractor so as to have all plumbing stubbed out 12" above sub -floor prior to installation. 5. Alignment pins shall be used for proper alignment of panels. 6. Any excess adhesive that may interfere with tubing installation shall be removed. 7. All burrs left by custom routing and on angle holes shall be removed. 8. Refer to manufacturer's installation manual for additional guidelines for this product. C. TUBING INSTALLATION 1. Holes for routing below sub -floor shall be drilled using an 1%6" bit at the correct location and in the appropriate direction, so that the end of the tube can be passed from the groove to under the floor area in the right direction, leading to the appropriate manifold location or the boiler panel. 2. All grooves shall be inspected and cleaned of any debris prior to tubing installation. 3. Tubing for radiant floor heating shall be %2" PEX approved by Warmboard, In. (See approved tubing list). 4. Tubing shall be and remain pressurized immediately following installation into the panel diaphragm for the duration of all construction. Caution, do not install silicone or other types of adhesives in tubing channel 5. Installer is responsible for protecting tubing from freezing during construction. Should climatic conditions occur, this would require adding antifreeze and corrosion inhibiting fluids upon completion of work. 6. Installer to record length of every pipe and photograph completed installation. 7. Special note for carpeted areas: Short pieces of PEX tubing (typically offcuts) shall be pressed into any unused groove areas. This provides support for the pad & carpet. REVISIONS: BY: O ■ U U 0 Q Zm Q ' 00@ � LU N Z �' Q `0 I..L a co J ��� VJ 0 �w 0 0� I) cy) O O X O U J ��W 0 C) �o M m O - Q O �° w O a0 W Q �� > E 06 U) Z O Z O Z O �Z < ~ J U U J D LL Q 0� U Cj (j W 0- Z — Z — U) DATE: SCALE: NTS DRAWN: J.McDONALD REVIEWED: J. M. SHEET: WB SPEC