Loading...
APPROVED PLANS BLDAREA OF WORK n - ?th St SW 212 t h St SW rD 212th St SW �d171fifl�S- ;v, Woodway High School 21 Sth 51 SW 0 m 1� a, d v a - c UD 99 `� 16th St Sw 216th 5t SVV 216th St 5VV 3 Swe i5h Edmonds FD Hospital x * G 218th St SW 212th St $1N 3 � Z19�h St 5W � � .� 0 CD T 3 � 220th St sw 220th 5t 5 220th 5t SW w o � � rD VICINITY MAP REQUIRED SUBMITTALS 1. SUBMIT A SUBMITTALS PRIORITY LIST AT THE PROJECT KICKOFF. 2. SUBMIT SUBSTITUTION REQUESTS TO ARCHITECT FOR APPROVAL. DO NOT USE PROPOSED SUBSTITUTION WITHOUT ARCHITECT'S WRITTEN APPROVAL. 3. PERFORMING WORK PRIOR TO MAKING REQUIRED SUBMITTALS IS NOT ACCEPTABLE AND MAY BE CAUSE FOR REJECTION. 4. SEISMIC SUBMITTALS: a. NON-STRUCTURAL ITEMS: SUBMIT PRODUCT DATA, MANUFACTURERS' INSTALLATION INSTRUCTIONS, AND OTHER DOCUMENTATION INDICATING TYPES OF SEISMIC RESTRAINTS REQUIRED FOR LAY -IN CEILINGS, SHELVING, CABINETS, AND OTHER PRODUCTS AND SYSTEMS TO ARCHITECT. 5. ARCHITECTURAL WOOD CASEWORK - SHOP DRAWINGS, FINISH SAMPLES IN A 2X3 INCH SIZE, AND PRODUCT DATA. 6. SUSPENDED ACOUSTICAL CEILINGS - PRODUCT DATA AND SAMPLES. 7. RESILIENT SHEET FLOORING - SHOP DRAWINGS INDICATING SEAM LAYOUT, PRODUCT DATA, AND SAMPLES. 8. PAINT - 3 SAMPLES OF EACH PROPOSED FINISH ON AN 8X10 INCH CARD. REFERENCE MANUFACTURER, TYPE OF PAINT, AND SHEEN. 9. WALL PROTECTION - PRODUCT DATA AND SAMPLES, IN 2X3 INCH SIZE, FOR MATERIAL AND ASSOCIATED TRIM. 10. EQUIPMENT - SHOP DRAWINGS AND PRODUCT DATA INDICATING SPECIFIED ACCESSORIES AND FINISH. 11. DELEGATED DESIGN SUBMITTALS: a. FIRE PROTECTION - SHOP DRAWINGS INDICATING LOCATIONS OF SPRINKLER HEADS, SMOKE/HEAT DETECTORS, AND SPEAKERS. b. HVAC - HVAC PLAN INDICATING LOCATIONS DIFFUSERS, GRILLES, SPRINKLER HEADS, AND OTHER MECHANICAL COMPONENTS EXPOSED TO VIEW IN FINISHED WORK. C. ELECTRICAL - POWER PLAN INDICATING LOCATION OF OUTLETS AND WALL SWITCHES. d. LIGHTING - LIGHTING PLAN AND PRODUCT DATA. ---------------------------- Scope of work for this permit is i i limited to replacement of gantry and i `patient table for new CT scanner_ - _ -� --------------------------------� i SPECIAL INSPECTIONS. Eight total retrofit i i bolts in concrete, either wedge anchors or i i epoxy. 4 each at Gantry and patient table. i Special inspection required, by FOR or WABO certified agency. See Structural Calculation packet for installation placement ! and instructions. Packet to remain on site for , inspections. ---------------------------------- City Of Edmonds Building Department Work NEW CT SCANNER Address 21605 76TH AVE W Owner SWEDISH HOSPITAL ---------------------- Approved Date: 08/13/2021 Building Official ---------------------------- Permit Number BLD2021-1095 CITY OF EDMONDS BUILDING DIVISION APPROVED PLAN KEY PLAN 1 " = 20'-0" CODE INFORMATION NOTES 1. ALL CONSTRUCTION WORK SHALL BE DONE IN COMPLIANCE WITH APPLICABLE CODE(S). 2. MAINTAIN 100% COVERAGE FROM EXISTING FIRE SPRINKLER AND SMOKE FIRE ALARM SYSTEMS PER FMO. 3. ALL EMERGENCY LIGHTING, SPRINKLERS, FIRE DETECTORS, FIRE ALARM COMMUNICATION DEVICES, AND ALL OTHER REQUIREMENTS TO CONFORM TO WASHINGTON STATE BUILDING AND LIFE SAFETY CODE CONTRACTOR INFORMATION- 1 . VERIFY DIMENSIONS AND CONDITIONS PRIOR TO CONSTRUCTION. NOTIFY ARCHITECT OF CONFLICTS PRIOR TO THE START OF CONSTRUCTION. 2. ALL DIMENSIONS ARE FROM FACE OF FINISH UON. 3. KEEP THE AREA OF WORK FREE OF GARBAGE AND DEBRIS ON A DAILY BASIS. 4. UPON COMPLETION OF THE WORK, CLEAN THE PREMISES AND WASH ANY WINDOWS SO THE SPACE IS READY FOR OCCUPANY OF TENANT. 5. WARRANTEE PARTS, LABOR, EQUIPMENT,AND MATERIALS PROVIDED UNDER THIS CONTRACT FOR A PERIOD OF ONE (1) YEAR UPON COMPLETION OF CONTRACT. 6. SUBMIT SUBSTITIONS TO ARCHITECT PRIOR TO IMPLEMENTATION. 7. SUBMIT CONTRACTOR DESIGNED ITEMS TO THE ARCHITECT PRIOR TO CONSTRUCTION. 8. ADDITIONAL DRAWINGS AND SPECIFICATIONS REQUIRED FOR PERMITS TO BE SUPPLIED BY THE CONTRACTOR. 9. ALL WORK LISTED, SHOWN, OR IMPLIED ON ANY CONSTRUCTION DOCUMENTS SHALL BE SUPPLIED AND INSTALLED BY THE GENERAL CONTRACTOR UNLESS NOTED OTHERWISE. THE GENERAL CONTRACTOR SHALL CLOSELY COORDINATE ALL WORK TO ASSURE ALL SCHEDULES ARE MET AND ALL WORK IS DONE IN CONFORMANCE TO MANUFACURER'S REQUIREMENTS. 10. DESIGN -BUILD WORK: CONTRACTOR TO PROVIDE ALL DOCUMENTATION INCLUDING SHOP DRAWINGS NECESSARY FOR CONSTRUCTION AND PERMITS. PROVIDE ARCHITECT WITH DESIGN -BUILD DRAWINGS FOR REVIEW. 11. MATCH EXISTING CONDITIONS AND FINISHES ATALL LOCATIONS UNLESS NOTED OTHERWISE. REFER TO THE FINISH SCHEDULED FOR ALL FINISH MATERIALS. 12. ALL NEW CASEWORK AND MILLWORK SHALL BE CONSTRUCTED TO AWI "PREMIUM" STANDARDS UNLESS NOTED OTHERWISE. 13. PROVIDE BLOCKING AND OTHER CONCEALED SUPPORTS WITHIN WALLS AS REQUIRED TO SUPPORT CASEWORK. REPLACEMENT nnrn t,%r%eif'%nv SCOPE OF WORK SHEET INDEX Sheet Number Sheet Name A0.00 I COVER SHEET PLAN IA4.01 I EQUIPMENT PLAN & ELEVATIONS PROJECT TEAM BUILDING ADDRESS 21605 76TH AVE W EDMONDS, WA 99026 OWNER/LANDLORD SWEDISH MEDICAL CENTER 600 BROADWAY, SUITE 300 SEATTLE, WA 98122 CONTACT: RICHARD BRAYTON PHONE: 206.320.7487 EMAIL: RICHARD. BRAYTON@SWEDISH.ORG ARCHITECT ANKROM MOISAN ARCHITECTS, INC. PROJECT 1505 5TH AVE., SUITE 300 SEATTLE, WA 98101 PHONE: 206.576.1600 FAX: 206.447.5514 CONTACT: CHRIS COOPER PHONE: 206.240.7572 INTERIOR ALTERATIONS OF APPROXIMATELY 560SF IN THE EXISTING CT IMAGING ROOM ON THE FIRST FLOOR AT SWEDISH HOSPITAL. ARCHITECTURAL WORK WILL INCLUDE NEW FINISHES INCLUDING CEILING TILE, COUNTER TOPS, AND FLOORING. THE PROJECT INCLUDES IMAGING EQUIPMENT REPLACEMENT AND ASSOCIATED CONTROL ROOM COMPONENTS WHICH WILL BE PROVIDED AND INSTALLED BY AN EQUIPMENT VENDOR. ELECTRICAL WORK INCLUDES UPGRADES TO THE EXISTING ELECTRICAL SYSTEM AS REQUIRED AND REPLACING EXISTING LIGHTS. ELECTRICAL WILL BE DESIGN -BUILD AND PERMITTED SEPARATELY. THE PROJECT WILL NOT IMPACT THE CONTINUOUS OPERATION OF THE SURROUNDING SUPPORT SPACES DURING CONSTRUCTION. THE LIFE SAFELY PLAN WILL NOT BE IMPACTED AS THE SQUARE FOOTAGE, NUMBER OF OCCUPANTS, AND PATH TO EXITS WILL REMAIN THE SAME. BUILDING INFORMATION SNOHOMISH COUNTY ASSESSOR'S PARCEL NUMBER: 00580700002500 LEGAL DESCRIPTION: SOLNERS 5 ACRE TRACTS BLK 000 D-00 - N 1 /2 OF TRS 27 & 28 & S 1 /2 OF TRS 25 & 26 TGW TH PTN OF VAC 10TH ST SE (FORMERLY 216TH ST SW ADJ THRTO) & TGW TH PTN OF TR 29 SD PLAT LY WILY OF FDL - COM AT NWCOR SD TR 29 TH ELY ALG N BDY 42.12FT TO BEG OF LN HEREIN DESC TH SLY TAP 35.44FT FIR SW CR OF SD TR 29 AS MEAS ALG S BDY SD TR & TERM OF LN HEREIN DESC (PER CITY EDM BLA REC AF NO 199909155005) APPLICABLE CODE(S): BUILDING CODE: 2018 INTERNATIONAL BUILDING CODE ELECTRICAL CODE: 2017 NATIONAL ELECTRICAL CODE MECHANICAL CODE: 2018 INTERNATIONAL MECHANICAL CODE FUEL GAS CODE: 2018 INTERNATIONAL FUEL GAS CODE PLUMBING CODE: 2018 UNIFORM PLUMBING CODE FIRE CODE: 2018 INTERNATIONAL FIRE CODE ENERGY CODE: 2018 WASHINGTON STATE ENERGY CODE ACCESSIBILITY CODES: ICC A117.1-2009 2010 ADA STANDARDS DOH: NFPA 101, 2012 EDITION FGI GUIDELINES, 2014 EDITION EXISTING PROPOSED CONSTRUCTION TYPE: 1A NO CHANGE SPRINKLERED: Y Y BUILDING STORIES (ABOVE GRADE): 2 FLOORS NO CHANGE BUILDING STORES (BELOW GRADE): 0 FLOORS NO CHANGE I BUILDING OCCUPANCY: 1-2 NO CHANGE REMODEL AREA: NO CHANGE OCCUPANT LOAD FOR EXISTING NO CHANGE REMODEL: TENANT CONTRACTOR SWEDISH MEDICAL CENTER DPR CONSTRUCTION 315 2ND AVE, SUITE 200 SEATTLE, WA 98104 CONTACT: CHRIS CLAYTON PHONE: 206.507.4289 EMAIL: CHRISCL@DPR.COM GENERAL NOTES GENERAL NOTES 1. VERIFY SITE CONDITIONS AND REPORT DISCREPANCIES TO THE ARCHITECT PRIOR TO CONSTRUCTION. DIMENSIONS 1. DO NOT SCALE THE DRAWINGS. WRITTEN DIMENSIONS GOVERN. 2. DO NOT ADJUST CLEAR DIMENSIONS WITHOUT APPROVAL OF THE ARCHITECT. 3. 'FLOOR LINE"FLOOR' OR'FLOOR LEVEL'REFER TO TOP OF CONCRETE SLAB OR TOP OF CEMENTITIOUS UNDERLAYMENT; FINISH FLOORING IS INSTALLED ABOVE THE FLOOR LINE. 4. 'FINISH FLOOR' REFERS TO THE TOP OF FLOORING. ACCESSIBILITY 1. REFER TO A0.05- A0.06 FOR ACCESSIBILITY REQUIREMENTS PERTAINING TO OUTLET LOCATIONS AND HEIGHTS, SWITCH LOCATIONS AND HEIGHTS, WALL BLOCKING, FLOOR CLEARANCES, COUNTERTOP HEIGHTS, ETC. 2. CHANGES IN FINISH FLOOR ELEVATION IN EXCESS OF 1/4", MEASURED FROM LOWEST POINT ON EITHER SIDE OF THRESHOLD TO HIGHEST POINT ON THRESHOLD, SHALL BE BEVELED AT 1:2. IN NO CASE SHALL FLOOR TRANSITIONS AND CHANGES IN LEVEL IN FLOOR SURFACE BE MORE THAN 1/4" MAX IN VERTICAL HEIGHT. DEFERRED SUBMITTALS FIRE SPRINKLER HVAC FIRE ALARMS ELECTRICAL 6054 REGISTERED ARCHITECT DAVE ONDO STATE OF ASHINGTON 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 (DANKROM MOISAN ARCHITECTS, INC. Z W 2 w U J CL W U i2r- LU V) l­_ LU Z �� J Lu rn U Q 0 LU Vl W 0 = Z V) U Ln O 0 O wW l,-O 0 Vi N Lu V) REVISION DATE REASON FOR ISSUE RECEIVED Aug 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT COVER SHEET PERMIT REVIEW DATE PROJECT NUMBER 8/6/2021 204970 SHEET NUMBER A0900 CI C!'Tf1 I f-AI f-LJ ACC 1 FURNITURE &EQUIPMENT PLAN I 1 /4" = 1'-0" STU D PLATE TRACK la a ELEVATION � COUNTER @STEEL SUPPORT J 1 1 /2" = 1 '-0" POWER DISTRIBUTION UNIT PARTIAL UPS LASER PROJECT FACE OF WALL BACKSPLASH L4" x 3" x 1/4" STEEL ANGLE COUNTERTOP #10 SCREWS (4) - 1 1/2" ON CENTER EACH WAY - PREDRILL HOLES IN PLATE #10 SCREWS @ 6" ON CENTER - PREDRILL HOLES IN PLATE 600S162-54 METAL STUD 1/4" x 3" x TSTEEL PLATE @ 24" ON CENTER ANCHOR BOLT -2" EMBED BASE FINISHED FLOOR MEN FURNITURE & EQUIPMENT PLAN LEGEND NOT IN CONTRACT (NIC) NEW EQUIPMENT EXISTING EQUIPMENT RECOMMENDED CLEARANCE BY MFG ------- REQ. CLEARANCE BY FGI & DOH ADA DOOR CLEARANCE n / / A I'_( f1 C' NOTE: IN -WALL COUNTER SUPPORT, REMOVE PORTION OF GYP BD AS REQUIRED FOR INSTALLATION, INSTALL BACKING OR ADDITIONAL PARTIAL FRAMING AS NECESSARY FOR INSTALLATION NOTE: (2) GROMMETS WITH LOCATIONS TO BE COORDINATED WITH OWNER ON SITE. ') CONTROL ROOM ELEVATION L 3/8" = 1 '-0" 'v 4 CAS EWO 1 1 /2" = 1 '-0" COUNTERTOP Y_[NC�'l9W_4ya —1-1A I! rI r!"' I( AI —IASE gnll ICTAMI C CUCI C - SEE INTERIOR ELEVATION FOR QUANTITY FACE OF WALL FIXED SHELF BASE FINISHED FLOOR RK @LOWER -DOOR SHELF 6054 REGISTERED ARCHITECT DAVE ONDO T ASHINGTON STATE OF 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 © ANKROM MOISAN ARCHITECTS, INC. Z LU 2 LU V J LU V w LU Z �� J O wM U Q LU LU lD c _ r-, Z V Ln O o Q w o � N Lu cn REVISION DATE REASON FOR ISSUE RECEIVED Aug 09 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2021-1095 EQUIPMENT PLAN & ELEVATIONS PERMIT REVIEW DATE PROJECT NUMBER 8/6/2021 204970 SHEET NUMBER A4190jr